HA48125E-10 [ETC]
120/240, 480 Vac / AC Output; 120/240 , 480 VAC / AC输出型号: | HA48125E-10 |
厂家: | ETC |
描述: | 120/240, 480 Vac / AC Output |
文件: | 总2页 (文件大小:81K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Series 1 - 110/125A
120/240, 480 Vac • AC Output
Featuring state-of-the-art Surface
• Zero Voltage and Random
Turn-On Switching
Mount Technology, these SPST-NO
relays deliver proven reliability in the
most demanding applications.
Output consists of an SCR AC switch
and is available in zero-cross, random
turn-on (phase controllable) and ver-
sions with either AC or DC input (coil)
control.
• Panel Mount
• Internal Snubber
Manufactured in Crydom’s ISO 9002
Certified facility for optimum product
performance and reliability.
AC CONTROL
DC CONTROL
A24110
D24110
A24125
D24125
HA48110
HD48110
HA48125
HD48125
MODEL NUMBERS
➀
OUTPUT SPECIFICATIONS
Operating Voltage (47-63 Hz) [Vrms]
Max. Load Current ➂ [Arms]
Min. Load Current, [mArms]
24-280
110
24-280
125
48-530
110
48-530
125
150
150
150
150
Transient Overvoltage [Vpk]
600
600
1200
1500
1.7
1200
1750
1.7
Max. Surge Current, (16.6ms) [Apk]
1500
1.7
1750
1.7
Max. On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (R ) [˚C/W]
.25
.22
.25
.22
θJC
2
2
Maximum I t for Fusing, (8.3 msec.) [A sec]
Max. Off-State Leakage Current @ Rated Voltage [mArms]
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁
Max. Turn-On Time ➃
9,340
10
12,700
10
9,340
10
12,700
10
500
500
500
500
1/2 Cycle (DC Control), 10.0 msec (AC Control)
1/2 Cycle (DC Control), 40.0 msec (AC Control)
Max. Turn-Off Time
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS ➀
DC CONTROL
AC CONTROL
AC CONTROL
( D P R E F I X )
( A P R E F I X )
( E S U F F I X )
Control Voltage Range
Max. Reverse Voltage
Max. Turn-On Voltage
Min. Turn-Off Voltage
Nominal Input Impedance
Typical Input Current
3-32 Vdc
-32 Vdc
90-280 Vrms (60Hz)
---
18-36 Vrms
---
3.0 Vdc
90 Vrms
18 Vrms
1.0 Vdc
10 Vrms
4.0 Vrms
1500 Ohms (120/240V Models) ➄
3.4mA @ 5 Vdc, 20mA @ 28Vdc➄
60K Ohms
9.0K Ohms
3mA @ 24 Vrms
2mA @ 120 Vrms, 4mA @ 240 Vrms
©1998 CRYDOM CORP, Specifications subject to change without notice.
GENERAL NOTES
➀ All parameters at 25ºC unless otherwise specified.
➁ Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
➂ Heat sinking required, for derating curves see page 2.
➃Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).
➄Input circuitry for 480V models incorporates active current limiter with 2mA typical input current..
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany
FastFax Document No. 152
110/125.040898, PAGE 1 OF 2
Series 1 - 110/125A
120/240, 480 Vac • AC Output
GENERAL SPECIFICATIONS
Dielectric Strength 50/60Hz Input/Output/Base
Insulation Resistance (Min.) @ 500 Vdc
Max. Capacitance Input/Output
4000 Vrms
109 Ohm
8 pF
Ambient Operating Temperature Range
Ambient Storage Temperature Range
-40 to 80ºC
-40 to 125ºC
MECHANICAL SPECIFICATIONS
Weight: (typical)
3.0 oz. (86.5g)
Encapsulation:
Terminals:
Thermally Conductive Epoxy
Screws and Saddle Clamps Furnished, Unmounted
AVAILABLE OPTIONS
24 Vac Input (18-36 Vac)
1.10
(27.9)
MOUNTING
HOLE/SLOT
0.17 (4.3) DIA.
E
8-32 TERMINAL
(2 PLACES )
.45
(11.4)
Example: A24110E
Screw Torque Requirements:
6-32 Screws - 10 in./lbs.,
8-32 and 10-32 Screws - 20in./lbs.
-10 Random Turn-On (AC & DC Control)
Phase Controllable (DC Control)
Example: D24110-10
OUTPUT
2.30
1
2
(Screws dry without grease.)
(58.4)
1.87
(47.5)
SOLID-STATE RELAY
1.70
(43.2)
--
+
4
3
INPUT
All dimensions are in inches (millimeters)
Crydom Heat Sinks offer excellent
thermal management and are per-
fectly matched to the load current
ratings of Crydom panel mount
relays. Request Crydom’s Heat Sink
specification sheet for all the details.
1.00
.78
BASE PLATE
.125 (3.2)
(25.4)
6-32 TERMINAL
(2 PLACES)
(19.8)
.90
(22.9)
1.80
(45.7)
CURRENT DERATING CURVES
110A
125A
160
120
80
160
90
90
.4ºC/W
.4ºC/W
.2ºC/W
120
.2ºC/W
.5ºC/W
.5ºC/W
100
100
110
120
80
1ºC/W
1ºC/W
110
120
40
0
40
0
30 60 90 120
Load Current [Arms]
0
20 40 60 80
Max Ambient Temp. [ºC]
30 60 90 120
Load Current [Arms]
0
20 40 60 80
Max Ambient Temp. [ºC]
©1998 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
APPROVALS
USA: (800) 8 CRYDOM • (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 812300 • fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU
GERMANY: (49)871 935405 • fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany
UL
E116950
FastFax Document No. 152
110/125.040898, PAGE 2 OF 2
相关型号:
©2020 ICPDF网 联系我们和版权申明