12-900Vdc  
Features:  
KILOVAC EV200 - 200/250 Amps ("Czonka III")  
Make & Break Load Switching  
Low Cost - lowest price sealed relay in the  
industry with its contact rating  
Highest contact rating for its size - 200/  
250 A carry, 2,000 A interrupt at 320 Vdc.  
Optional Auxillary Contact - Easy monitoring  
of power contact position  
Built-In Coil Economizer - Only 1.7 W hold  
power @ 12 Vdc making it ideal for battery  
powered systems. Models are available  
requiring external coil economizer for large  
volume applications  
US and Canadian UL Recognized - UL File No.  
E208033  
CE Marked for EC Applications  
AIAG QS9000, Design, Built & Approved  
Hermetically Sealed - Intrinsically safe,  
operates in explosive & harsh environments  
like salt, moisture, dust with no oxidation or  
contamination of coils or contacts providing  
stable contact resistance over years of use,  
including long periods of non-operation  
• Small & Lightweight - smallest sealed relay in  
the industry with its current rating  
No Coil Back EMF - Built-in coil economizer  
limits back EMF to zero volts  
Versatile Coil Connection - Flying leads or  
optional connectors  
Multiple use Applications - Ideal for battery  
switching & back-up, DC voltage power  
control, circuit protection and safety  
PRODUCT SPECIFICATIONS  
Part Number  
Units  
EV200  
SPST-NO  
SPST-NO  
A
Contact Arrangement : Power Contacts ........................................  
Aux. Contacts ...........................................  
Contact Form .................................................................................  
Carry Current, Continuous, Max @ 85oC, 1/0 cable  
100 Seconds ...........................................................................  
10 Seconds ...........................................................................  
Carry Current, Continuous, Max @ 50oC, 1/0 cable  
300 Seconds ...........................................................................  
100 Seconds ...........................................................................  
10 Seconds ............................................................................  
Starter Application (up to 10 repeats with 10 sec. off between)  
Inrush, 250 ms ........................................................................  
EV200 COIL DATA  
200  
Voltage (will operate)  
Vdc  
Vdc  
Vdc  
Vdc  
Vdc  
A
48 to 95  
9 to 36  
36  
32 to 95  
95  
325 3 /  
500 3 /  
250  
A
A
A
A
A
A
Voltage (max.)  
Pickup (close), max.  
Hold, Min.  
95  
48  
9.0  
32  
275  
34  
7.5  
22  
400  
Dropout (open), min.  
Inrush, max.  
27  
6.0  
18  
600  
.7  
3.8  
1.3  
Holding, avg.  
A
.02@72V  
130  
.13@12V, .07@24V .03@48V  
130 130  
2,000  
500  
A
A
Inrush Time, max.  
ms  
Cranking, 10 sec ......................................................................  
1 /  
Make & Break Current (various voltages)  
............................................................  
see back sheet  
2,000, 1 cyc 4 /  
2 / 3  
A
PART NUMBER SELECTION  
1 /  
Break Current @ 320 Vdc  
.......................................................................................................  
A
Sample Part No. EV200  
A
A
A
N
A
Aux. Contact Current, max @ 30 Vdc/125 Vac ..............................  
(no lower than 8V @ 100mA)  
A
Model  
EV200  
A
Aux. Contact Resistance, max. 30 Vdc/125 Vac ............................  
Load Life .......................................................................................  
Mechancial Life .............................................................................  
Contact Resistance, Max. (@200A) ...............................................  
Contact Resistance, Typ. (@200A) ................................................  
Operate Time, 25o C .......................................................................  
Close (includes bounce) Typ. ..................................................  
Bounce (after close only), Max. ...............................................  
Release Time (includes arcing), Max. @ 2,000A .....................  
Insulation Resistance @ 500 Vdc, Min. ........................................  
Dielectric at Sea Level (leakage < 1mA) ........................................  
Shock, 11 ms 1/2 Sine (peak), operating ......................................  
Vibration, Sinusoidal (80-2000 Hz, peak) .....................................  
Operating Ambient Temperature Range ........................................  
Weight, Nominal ...........................................................................  
.417/.150  
see back sheet  
1 million  
.4  
A
Form  
cycles  
cycles  
mohms  
mohms  
A = Normally Open  
H = Normally Open with Aux.  
Coil Voltage  
A = 9 to 36 (1 = requires external coil economizer)  
D = 32 to 95 (2 = requires external coil economizer)  
J = 48 to 95 (3 = requires external coil economizer)  
Coil Wire Length  
A = 390 mm (15.3")  
B = 152 mm (6.0")  
Coil Terminal Connector  
N = No Connector  
B = Yazaki 7282-5558-10 male, 7114-4102-02, 7158-3030-50  
+red is pin 2 (B length only)  
C = Molex Mini-fit Jr, 2 Ckt, Female 18-24, P/N 39-01-2020 &  
39-00-0060 +red is pin 1 (A length only)  
Mounting & Power Terminals  
A = Bottom Mount & Male 10mm x 8 Terminals  
.1 - .3  
15  
7
ms  
ms  
12  
ms  
2 /  
100  
Mohms  
Vrms  
2,200  
20  
G's peak  
G's  
oC  
20  
-40 to +85  
.95 (.43)  
pound (kg)  
1 /  
Main Power Contacts  
2/  
50 at end of life  
3 /  
Estimated  
4 /  
Does not meet dielectric & IR after test, 1,700 amp for unit with Aux. Contacts  
Rev. 9/2001  
CII Technologies / P.O. Box 4422 / Santa Barbara, CA 93140 / ph 805.684.4560 / fax 805.684.9679 / e-mail info@kilovac.com / website www.ciitech.com  
12-900Vdc  
Estimated Make & Break Power Switching Ratings  
C ontinu ous cu rrent ca rry regio n  
200A  
N on c ontinu ous cu rrent ca rry regio n  
100,000  
10,000  
1,000  
100  
10  
1
1
10  
100  
1,000  
10,000  
NOTES:  
1) FOR R E S IS TIV E L OA D S W IT H 30 0uH M A XIM U M IN D UC TA N CE  
Current (A )  
2) ES TIM A TE S BA S E D O N E X TRA P O L A TE D D AT A  
TO V E RIFY RA TIN G IN AC TU A L A PP L IC A TION  
. U S ER IS E NC OU R A G E D  
3) EN D O F LIFE W H EN DIE LE C TR IC ST RE N G TH BE TW E E N TE R M INA LS FA LL S B E LOW 50M  
@
500 VD C  
4) THE M A X IM UM C O N TA CT M A K E AN D B R E A K P O W E R IS E S TIM A TE D A T 208 K W . B RE A K ON LY A B OV E 20 8K W TO  
A V O ID C O N TA C T W E LD ING  
Electrical Load Life Ratings for Typical EV Applications  
Make/Break Life Capacitive & Resistive Loads at 320 Vdc 1 / 2 /  
@90% capacitive pre-charge (make only) see chart below  
@80% capacitive pre-charge (make only) see chart below  
@200 A make/break (2 consecutive, reverse polarity) 1 /  
2,000 A - break only (1,700 A for Aux. Contact Model) 1 /  
Mechanical Life  
Cycles  
Cycles  
Cycles  
Cycles  
Cycles  
50,000  
50  
12  
1*  
1,000,000  
1 / Resistive load includes inductance L = 25 uH. Load @ 2500 A tested @ 200 uH.  
2 / Life based on projected Weibull Life with 95% Reliability  
*
Does not meet dielectric & IR after test.  
EV200 Capacitive Make Test Curves for Pre-Charged Motor Controller  
700  
650  
600  
550  
500  
450  
400  
350  
300  
250  
200  
150  
100  
50  
80% Minimum  
Pre Charge  
90% Nominal  
Pre Charge  
0
0.0  
0.5  
1.0  
1.5  
2.0  
mS  
Rev. 9/2001  
CII Technologies / P.O. Box 4422 / Santa Barbara, CA 93140 / ph 805.684.4560 / fax 805.684.9679 / e-mail info@kilovac.com / website www.ciitech.com  

相关型号:

EV200-250

Make & Break Load Switching
ETC

EV2000DJ-00A

Low Input Voltage 150mA Linear Regulator Evaluation Board
MPS

EV200AAABA

KILOVAC EV200 Series Contactor With 1 Form X Contacts Rated 500+ Amps, 12-900VDC
TE

EV200AAACA

KILOVAC EV200 Series Contactor With 1 Form X Contacts Rated 500+ Amps, 12-900VDC
TE

EV200AAANA

KILOVAC EV200 Series Contactor With 1 Form X Contacts Rated 500+ Amps, 12-900VDC
TE

EV200AABBA

KILOVAC EV200 Series Contactor With 1 Form X Contacts Rated 500+ Amps, 12-900VDC
TE

EV200AABCA

KILOVAC EV200 Series Contactor With 1 Form X Contacts Rated 500+ Amps, 12-900VDC
TE

EV200AABNA

KILOVAC EV200 Series Contactor With 1 Form X Contacts Rated 500+ Amps, 12-900VDC
TE

EV200ADABA

KILOVAC EV200 Series Contactor With 1 Form X Contacts Rated 500+ Amps, 12-900VDC
TE

EV200ADACA

KILOVAC EV200 Series Contactor With 1 Form X Contacts Rated 500+ Amps, 12-900VDC
TE

EV200ADANA

KILOVAC EV200 Series Contactor With 1 Form X Contacts Rated 500+ Amps, 12-900VDC
TE

EV200ADBBA

KILOVAC EV200 Series Contactor With 1 Form X Contacts Rated 500+ Amps, 12-900VDC
TE