C517-3A [ETC]

Fuse ; 保险丝\n
C517-3A
型号: C517-3A
厂家: ETC    ETC
描述:

Fuse
保险丝\n

文件: 总2页 (文件大小:55K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
®
Bu s s m a n n  
Lig h t Ba lla s t P ro t e c t io n  
5 m m x 1 5 m m Ce ra m ic Fu s e  
C5 1 7  
Dimensional Data  
±
15.0 0.5mm  
5.2 ± 0.3mm  
5.0mm (Typ.)  
0.6mm Dia. (Typ)  
Markings: Manufacturer’s Symbol,  
Product Symbol, Voltage, Ampere,  
Testing Agency Mark (Optional)  
Dimensions are in  
Millimeters (mm)  
Time-Current Characteristic Curves–Average Melt  
(Full Size Curves Available)  
AMPERE  
RATING  
100  
C517 Axial Leaded Fast-Acting Fuse.  
Limits for Pre-arcing Time/UL Listed Fuses.  
135%  
MAX  
1 hr.  
110%  
MIN  
200%  
MAX  
Amp Ratings  
10  
3A  
4 hr.  
2 sec.  
Time-Current Characteristics: (at 25°C Ambient)  
Current  
3.30  
% of Rating  
100%  
135%  
200%  
300%  
400%  
500%  
800%  
1000%  
Opening Time  
4 hours min.  
400 sec. typ.  
0.550 sec. typ.  
0.100 sec. typ.  
0.046 sec. typ.  
0.027 sec. typ.  
0.007 sec. typ.  
0.004 sec. typ.  
4.05A  
6.00A  
9.00A  
12.0A  
15.0A  
24.0A  
30.0A  
1
.1  
Agency File Numbers: UL Listing. File E75865,  
Guide # JDYX.  
CSA Certification. File LR65063,  
Class 1422-01.  
UL Recognized. File E75865,  
Guide # JDYX2.  
.01  
CURRENT IN AMPERES  
Product Symbol:  
C517  
Physical Fuse Size:  
5 x 15mm  
Mechanical Characteristics:  
Materials:  
Endcaps are silver-plated brass; leads are  
tin-plated copper and tube is glass.  
CE logo denotes compliance with European Union Low Voltage Directive  
(50-1000V AC, 75-1500V DC). Refer to BIF document #8002 or contact  
Bussmann Application Engineering at 314-527-1270 for more information.  
Optional sleeve is flexible fluoropolymer (UL  
Flammability rating VW-1). The tube will self  
extinguish within one minute. 25% maximum  
flag burn per ASTM Flammability Test ASTM  
D2671 Procedure C.  
Lead Pull:  
Leads will withstand a seven pound pull  
applied axially to the lead for five seconds.  
Lead Bend:  
Leads will be bent 90 degrees in one direction,  
back to original direction, then 90 degrees in  
the opposite direction and return to the cycle.  
Leads will withstand two cycles. The bending  
is to be done with a two pound weight  
attached to the end of the lead.  
Temp. Range: -55°C to +85°C with proper derating.  
Weight: 1000 = 1.33kg.  
Form No. C517  
Page 1 of 2  
BIF Doc #2025  
12-17-98  
SB98107  
Rev. A  
®
Bu s s m a n n  
Lig h t Ba lla s t P ro t e c t io n  
5 m m x 1 5 m m Ce ra m ic Fu s e  
C5 1 7  
Electrical Characteristics:  
Max. Rated  
Voltage  
AC  
Typical  
Pre-arcing  
Typical Voltage  
Drop at 100%  
Rated Current (mV)  
Ampere  
Rating  
Interrupting  
Rating  
2
2
I t (A S)  
100A/350VAC  
p.f. = 1.0  
100A/250VAC  
p.f. = 0.7 - 0.8  
3A  
350V  
5.2  
160  
10kA/125VAC  
p.f. = 0.7 - 0.8  
Marking: Endcaps will bear the following markings: manufacturer’s symbol, product symbol, ampere rating, agency approval symbols and voltage rating  
(250V).  
Note: parts can not be marked 350V since there is no provision within the CSA Standards for a 350V certification of a product in this case size.  
Smallest packages will bear 125V, 250V and 350V rating information.  
Packaging & Ordering Information:  
C517  
3A  
Product  
Symbol  
Ampere  
Rating  
Blank - Standard  
S - Transparent  
sleeve for  
Package Code  
sealed fuses.  
BK/ Bulk Package (100 pcs)  
TR/ Tape & Reel (500 pcs)  
TR1/ Tape & Reel (1,000 pcs)  
TR2/ Tape & Reel (1,500 pcs)  
NOTE: Tape & Reel Packaging  
per EIA 296-E (10.2mm Component  
Pitch and 52.4mm Tape-to-Tape Spacing)  
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled. This bulletin is intended to  
clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any  
products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been select-  
ed, it should be tested by the user in all possible applications.  
Form No. C517  
Page 2 of 2  
BIF Doc #2025  
12-17-98  
SB98107  
Rev. A  

相关型号:

C5174G

5000 WATTS (AC) DC/D CSINGLE OUTPUT
POWERBOX

C5174K

5000 WATTS (AC) DC/D CSINGLE OUTPUT
POWERBOX

C5174V

5000 WATTS (AC) DC/D CSINGLE OUTPUT
POWERBOX

C5175G

5000 WATTS (AC) DC/D CSINGLE OUTPUT
POWERBOX

C5175K

5000 WATTS (AC) DC/D CSINGLE OUTPUT
POWERBOX

C5175V

5000 WATTS (AC) DC/D CSINGLE OUTPUT
POWERBOX

C5176G

5000 WATTS (AC) DC/D CSINGLE OUTPUT
POWERBOX

C5176K

5000 WATTS (AC) DC/D CSINGLE OUTPUT
POWERBOX

C5176V

5000 WATTS (AC) DC/D CSINGLE OUTPUT
POWERBOX

C5177G

5000 WATTS (AC) DC/D CSINGLE OUTPUT
POWERBOX

C5177GJ

5000 WATTS (AC) DC/D CSINGLE OUTPUT
POWERBOX

C5177K

5000 WATTS (AC) DC/D CSINGLE OUTPUT
POWERBOX