BBA-322-A_08 [ETC]

BBA SERIES RF AMPLIFIER DATA GUIDE; BBA系列射频放大器数据指南
BBA-322-A_08
型号: BBA-322-A_08
厂家: ETC    ETC
描述:

BBA SERIES RF AMPLIFIER DATA GUIDE
BBA系列射频放大器数据指南

射频放大器
文件: 总7页 (文件大小:184K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
BBA-322-A  
BBA-519-A  
WIRELESS MADE SIMPLE ®  
BBA SERIES RF AMPLIFIER DATA GUIDE  
DESCRIPTION  
The BBA Series is a family of low-cost high-  
performance broadband RF amplifiers. The  
modules are ideally suited to a wide range of  
amplification and buffering applications,  
including extending the range of Linx’s own RF  
modules (where legally appropriate). Housed in  
a compact SMD package, the hybrid amps are  
matched to 50Ω source and load impedances.  
The modules utilize a GaHBT gain stage, which  
yields high gain and IP3, excellent flatness, and  
low noise. The BBA-322-A is the high gain  
model and is suitable for the LNA stage of many  
receivers. This extra gain stage on the front end  
of a receiver can improve the sensitivity and  
AMP MODULE  
BBA-519-A  
LOT 0100  
0.360"  
0.500"  
0.130"  
Typ.  
Figure 1: BBA Package Dimensions  
provide a greater range for the product. The BBA-519-A is the high power model and  
is suitable for the final gain stage in a transmitter. This amplifier can boost the output  
power of a transmitter to much higher levels and provide a significant increase in  
range (where legally appropriate).  
BBA SERIES FEATURES  
„ Prematched for 50Ω impedance  
„ No external RF components  
required  
„ Exceptional gain flatness  
„ Compact SMD package  
„ Operates from a single supply  
BBA-322-A FEATURES  
BBA-519-A FEATURES  
„ High gain  
„ High output  
„ 3.8dB noise figure  
„ DC-3GHz broadband operation  
„ +20dB small signal gain at  
900MHz  
„ Up to +10dB (10mW) linear  
output power  
„ 4.8dB noise figure  
„ 10MHz-3GHz broadband  
operation  
„ +18dB small signal gain at  
900MHz  
„ Up to +17dB (50mW) linear  
output power  
APPLICATIONS INCLUDE  
ORDERING INFORMATION  
„ TX / RX Range Enhancement  
„ IF or RF Buffering  
„ Driver or Final Stage for PA  
„ General Purpose Gain Blocks  
PART #  
DESCRIPTION  
BBA-322-A  
BBA-519-A  
High Gain RF Amplifier  
High Power RF Amplifier  
Amplifiers are supplied in tubes of 50 pcs.  
Revised 1/28/08  
BBA-322-A ELECTRICAL SPECIFICATIONS  
BBA-519-A ELECTRICAL SPECIFICATIONS  
Parameter  
Designation  
Min.  
Typical  
Max.  
Units  
Notes  
Parameter  
Designation  
Min.  
Typical  
Max.  
Units  
Notes  
POWER SUPPLY  
Operating Voltage  
POWER SUPPLY  
Operating Voltage  
VCC  
ICC  
4.8  
5.2  
VDC  
mA  
1
VCC  
ICC  
4.8  
5.2  
VDC  
mA  
1
Supply Current  
AMPLIFIER SECTION  
Frequency Range  
Gain:  
35.0  
65.0  
Supply Current  
AMPLIFIER SECTION  
Frequency Range  
Gain:  
60.0  
65.0  
FC  
DC  
-50  
3,000  
MHz  
kHz  
dB  
2
3
4
5
5
6
4
FC  
10  
-50  
4,000  
MHz  
kHz  
dB  
2
3
4
5
5
6
7
+50  
+50  
@ 100MHz  
21.0  
20.0  
17.0  
14.0  
2
@ 100MHz  
18.5  
17.5  
15.5  
13.5  
12.5  
2
@ 1,000MHz  
@ 2,000MHz  
@ 3,000MHz  
Gain Ripple  
dB  
@ 1,000MHz  
@ 2,000MHz  
@ 3,000MHz  
@ 4,000MHz  
Gain Ripple  
dB  
dB  
dB  
dB  
dB  
dB  
dB  
Noise Figure  
Input VSWR  
Output VSWR  
Output IP3  
3.8  
dB  
dB  
2.3  
Noise Figure  
Input VSWR  
Output VSWR  
Output IP3  
4.8  
dB  
2.1  
2.1  
+22.5  
+11.2  
dBm  
dBm  
1.8  
Output P1dB  
+33  
+18.5  
dBm  
dBm  
Output P1dB  
Reverse Isolation  
20  
dB  
4
ANTENNA PORT  
Reverse Isolation  
20  
dB  
4
RF Input Impedance  
ENVIRONMENTAL  
Operating Temperature Range  
RIN  
50  
Ω
ANTENNA PORT  
RF Input Impedance  
ENVIRONMENTAL  
Operating Temperature Range  
RIN  
50  
Ω
-40  
+85  
°C  
-40  
+85  
°C  
Notes  
1. 5.2V to 12V range is possible with the appropriate current-limiting resistor.  
2. T = 25°C, ICC = 35mA.  
Notes  
1. 5.2V to 12V range is possible with the appropriate current-limiting resistor.  
2. T = 25°C, ICC = 65mA.  
3. 100MHz to 2,000MHz.  
4. At 2,000MHz.  
5. In a 50Ω system, DC to 3,000MHz.  
6. At 2,000MHz 50kHz, PTONE = -18dBm.  
3. 100MHz to 2,000MHz.  
4. At 2,000MHz.  
5. In a 50Ω system, DC to 4,000MHz.  
6. At 1,000MHz 50kHz, PTONE = -10dBm.  
7. At 1,000MHz.  
ABSOLUTE MAXIMUM RATINGS  
ABSOLUTE MAXIMUM RATINGS  
Supply Voltage VCC  
Supply Current  
RF Input  
Operating Temperature  
Storage Temperature  
Soldering Temperature  
+4.8  
to  
65  
+15  
to  
+5.2  
VDC  
mA  
dBm  
°C  
Supply Voltage VCC  
Supply Current  
+4.8  
to  
120  
+13  
to  
+5.2  
VDC  
mA  
dBm  
°C  
0
-60  
+70  
+150  
RF Input  
to  
°C  
Operating Temperature  
Storage Temperature  
Soldering Temperature  
0
-60  
+70  
+150  
+225°C for 10 seconds  
to  
°C  
*NOTE* Exceeding any of the limits of this section may lead to permanent  
damage to the device. Furthermore, extended operation at these maximum  
ratings may reduce the life of this device.  
+225°C for 10 seconds  
*NOTE* Exceeding any of the limits of this section may lead to permanent  
damage to the device. Furthermore, extended operation at these maximum  
ratings may reduce the life of this device.  
*CAUTION*  
This product incorporates numerous static-sensitive components.  
Always wear an ESD wrist strap and observe proper ESD handling  
procedures when working with this device. Failure to observe this  
precaution may result in module damage or failure.  
*NOTE* The purchaser of this device should be aware that approvals may be  
required by applicable governing bodies for systems producing RF energy. It  
is the responsibility of the user to determine and adhere to the appropriate  
regulations for the region in which operation is intended.  
Page 2  
Page 3  
PERFORMANCE DATA  
THEORY OF OPERATION  
These performance parameters  
are based on module operation at  
25°C from a 5.0VDC supply with a  
-50dBm input unless otherwise  
noted. Figure 2 illustrates the  
connections necessary for testing  
and operation. It is recommended  
all ground pins be connected to the  
ground plane.  
The BBA Series is a family of low-cost, high-performance, broadband RF  
amplifiers. They utilize an advanced Gallium Arsenide Heterojunction Bipolar  
Transistor (HBT) gain stage, which yields high gain and IP3, excellent flatness,  
and low noise. They are self-contained with 50Ω input and output impedances  
and require only one external DC biasing resistor to operate as specified.  
VCC  
1
2
3
4
8
7
6
5
GND RF OUT  
VCC  
GND  
GND  
GND  
GND  
RF IN  
The BBA-322-A is the high gain model and is suitable for the LNA stage of many  
receivers. This extra gain stage on the front end of a receiver can improve the  
sensitivity and provide a greater range for the product.  
BBA-519-A  
GND  
GND  
Figure 2: Test / Basic Application Circuit  
The BBA-519-A is the high power model and is suitable for the final gain stage  
in a transmitter. This amplifier can boost the output power of a transmitter to  
much higher levels and provide a significant increase in range (where legally  
appropriate).  
PIN ASSIGNMENTS  
1
2
3
4
GND RF OUT  
8
VCC  
VCC  
GND  
RF IN  
GND  
GND  
GND  
7
6
5
RF OUT  
Figure 3: BBA Series Amplifier Pinout (Top View)  
RF IN  
PIN DESCRIPTIONS  
Pin # Name  
Description  
Analog Ground  
Supply Voltage  
Analog Ground  
50-ohm RF Input  
Analog Ground  
Analog Ground  
Analog Ground  
50-ohm RF Output  
1
2
3
4
5
6
7
8
GND  
VCC  
GND  
RF IN  
GND  
GND  
Figure 4: BBA Series Amplifier Schematic  
GND  
OPERATIONAL CONSIDERATIONS  
GND  
The use of a gain stage can produce a significant increase in the range  
performance of an RF link. It is important to note that it can also introduce  
detrimental effects, such as the following:  
RF OUT  
Table 1: BBA Series Amplifier Pin Descriptions  
• Amplification of harmonics and LO along with the fundamental carrier frequency.  
• Adverse effect on the front-end noise figure on receivers.  
• Potential damage if the receiver input is not capable of accommodating high  
input power levels.  
• Risk of generating illegal power levels and unacceptable interference.  
It is up to the designer to ensure that the final product will comply with all  
appropriate regulations in the county of intended use.  
Page 4  
Page 5  
POWER SUPPLY REQUIREMENTS  
TYPICAL APPLICATIONS  
The module does not have an internal voltage  
regulator; therefore it requires a clean, well-regulated  
power source. While it is preferable to power the unit  
from a battery, the unit can also be operated from a  
power supply as long as noise is less than 20mV.  
Power supply noise can significantly affect the  
performance; therefore, providing a clean power  
supply for the module should be a high priority during  
design.  
The schematic in the figure below shows a typical configuration for amplifying the  
output of a transmitter.  
Vcc TO  
MODULE  
10Ω  
VCC  
Vcc IN  
+
VCC  
10μF  
1
8
7
6
5
GND RF OUT  
GND  
GND  
GND  
GND  
270
Ω
 
Figure 5: Supply Filter  
1
10  
9
4
PDN  
VCC  
ANT  
GND  
RF IN  
BBA-519-A  
A 10Ω resistor in series with the supply followed by a 10µF tantalum capacitor  
from VCC to ground will help in cases where the quality of supply power is poor.  
These values may need to be adjusted depending on the noise present on the  
supply line.  
3
4
8
LO V D  
GND  
7
6
GND /CLK SE  
/CLK  
GND  
TX DATA  
TXM-xxx-ES  
GND  
The power supply must be regulated to within the primary range specified or the  
maximum current limited using an appropriate resistance in series with the  
amplifier’s positive supply pin. Failure to observe the supply limits will irreparably  
damage the device. The resistor should be selected so that the device current is  
limited to or less than the maximum rated current. The resistor value may be  
easily selected using the following formula:  
Figure 6: Typical Application Circuit  
In this circuit, the BBA-519-A amplifies the output of the ES Series transmitter.  
The transmitter operates on 3V while the amplifier requires 5V, so a 270Ω  
resistor is used to drop the 5V supply to 3V for the transmitter.  
V
- V  
DEVICE TYP.  
This configuration would result in a 6 to 7 times increase in system range. Note  
that such output levels may render the transmitter illegal for operation in certain  
countries, so it is up to the designer to ensure that the product will comply with  
the appropriate regulations.  
SUPPLY  
R =  
I
CC  
Example:  
BBA-519-A @ 9V Supply  
9 - 5  
9 - 5  
4
= 66Ω  
R =  
=
=
-3  
-3  
60x10  
60x10  
0.06  
Page 6  
Page 7  
BOARD LAYOUT GUIDELINES  
MICROSTRIP DETAILS  
If you are at all familiar with RF devices, you may be concerned about  
specialized board layout requirements. Fortunately, because of the care taken by  
Linx in designing the modules, integrating them is very straightforward. Despite  
this ease of application, it is still necessary to maintain respect for the RF stage  
and exercise appropriate care in layout and application in order to maximize  
performance and ensure reliable operation. The antenna can also be influenced  
by layout choices. Please review this data guide in its entirety prior to beginning  
your design. By adhering to good layout principles and observing some basic  
design rules, you will be on the path to RF success.  
A transmission line is a medium whereby RF energy is transferred from one  
place to another with minimal loss. This is a critical factor, especially in high-  
frequency products like Linx RF modules, because the trace leading to the  
module’s antenna can effectively contribute to the length of the antenna,  
changing its resonant bandwidth. In order to minimize loss and detuning, some  
form of transmission line between the antenna and the module should be used,  
unless the antenna can be placed very close (<1/8in.) to the module. One  
common form of transmission line is a coax cable, another is the microstrip. This  
term refers to a PCB trace running over a ground plane that is designed to serve  
as a transmission line between the module and the antenna. The width is based  
on the desired characteristic impedance of the line, the thickness of the PCB,  
and the dielectric constant of the board material. For standard 0.062in thick FR-  
4 board material, the trace width would be 111 mils. The correct trace width can  
be calculated for other widths and materials using the information below. Handy  
software for calculating microstrip lines is also available on the Linx website,  
www.linxtechnologies.com.  
The adjacent figure shows the suggested  
PCB footprint for the module. The actual pad  
dimensions are shown in the Pad Layout  
section of this manual. A ground plane (as  
large as possible) should be placed on a  
lower layer of your PC board opposite the  
GROOUUNNDD PPLLAANNEE  
ON LLOWER LAYER  
module. This ground plane can also be critical  
to the performance of your antenna, which will  
be discussed later. There should not be any  
Trace  
ground or traces under the module on the  
same layer as the module, just bare PCB.  
Figure 7: Suggested PCB Layout  
Board  
During prototyping, the module should be soldered to a properly laid-out circuit  
board. The use of prototyping or “perf” boards will result in horrible performance  
and is strongly discouraged.  
Ground plane  
No conductive items should be placed within 0.15in of the module’s top or sides.  
Do not route PCB traces directly under the module. The underside of the module  
has numerous signal-bearing traces and vias that could short or couple to traces  
on the product’s circuit board.  
The module’s ground lines should each have their own via to the ground plane  
and be as short as possible.  
The module should, as much as reasonably possible, be isolated from other  
components on your PCB, especially high-frequency circuitry such as crystal  
oscillators, switching power supplies, and high-speed bus lines. Make sure  
internal wiring is routed away from the module and antenna, and is secured to  
prevent displacement.  
The power supply filter should be placed close to the module’s VCC line.  
In some instances, a designer may wish to encapsulate or “pot” the product.  
Many Linx customers have done this successfully; however, there are a wide  
variety of potting compounds with varying dielectric properties. Since such  
compounds can considerably impact RF performance, it is the responsibility of  
the designer to carefully evaluate and qualify the impact and suitability of such  
materials.  
Figure 8: Microstrip Formulas  
Effective Dielectric  
Constant  
Characteristic  
Impedance  
Dielectric Constant Width/Height (W/d)  
The trace from the module to the antenna should be kept as short as possible.  
A simple trace is suitable for runs up to 1/8-inch for antennas with wide  
bandwidth characteristics. For longer runs or to avoid detuning narrow bandwidth  
antennas, such as a helical, use a 50-ohm coax or 50-ohm microstrip  
transmission line as described in the following section.  
4.80  
4.00  
2.55  
1.8  
2.0  
3.0  
3.59  
3.07  
2.12  
50.0  
51.0  
48.0  
Page 8  
Page 9  
PAD LAYOUT  
AUTOMATED ASSEMBLY  
The following pad layout diagram is designed to facilitate both hand and  
automated assembly.  
For high-volume assembly, most users will want to auto-place the modules. The  
modules have been designed to maintain compatibility with reflow processing  
techniques; however, due to the their hybrid nature, certain aspects of the  
assembly process are far more critical than for other component types.  
0.065"  
Following are brief discussions of the three primary areas where caution must be  
observed.  
Reflow Temperature Profile  
0.340"  
0.070"  
The single most critical stage in the automated assembly process is the reflow  
stage. The reflow profile below should not be exceeded, since excessive  
temperatures or transport times during reflow will irreparably damage the  
modules. Assembly personnel will need to pay careful attention to the oven’s  
profile to ensure that it meets the requirements necessary to successfully reflow  
all components while still remaining within the limits mandated by the modules.  
The figure below shows the recommended reflow oven profile for the modules.  
0.100"  
Figure 9: Recommended PCB Layout  
PRODUCTION GUIDELINES  
300  
Recommended RoHS Profile  
Max RoHS Profile  
Recommended Non-RoHS Profile  
The modules are housed in a hybrid SMD package that supports hand or  
automated assembly techniques. Since the modules contain discrete  
components internally, the assembly procedures are critical to ensuring the  
reliable function of the modules. The following procedures should be reviewed  
with and practiced by all assembly personnel.  
255°C  
250  
200  
150  
100  
50  
235°C  
217°C  
185°C  
180°C  
HAND ASSEMBLY  
Pads located on the bottom of the  
module are the primary mounting  
surface. Since these pads are  
inaccessible during mounting,  
Soldering Iron  
Tip  
125°C  
castellations that run up the side of  
the module have been provided to  
facilitate solder wicking to the  
module’s underside. This allows for  
very quick hand soldering for  
Solder  
PCB Pads  
0
30  
60  
90  
120  
150  
180  
210  
240  
270  
300  
330  
360  
Castellations  
Time (Seconds)  
prototyping and small volume  
Figure 11: Maximum Reflow Profile  
Figure 10: Soldering Technique  
production.  
If the recommended pad guidelines have been followed, the pads will protrude  
slightly past the edge of the module. Use a fine soldering tip to heat the board  
pad and the castellation, then introduce solder to the pad at the module’s edge.  
The solder will wick underneath the module, providing reliable attachment. Tack  
one module corner first and then work around the device, taking care not to  
exceed the times listed below.  
Shock During Reflow Transport  
Since some internal module components may reflow along with the components  
placed on the board being assembled, it is imperative that the modules not be  
subjected to shock or vibration during the time solder is liquid. Should a shock  
be applied, some internal components could be lifted from their pads, causing  
the module to not function properly.  
Washability  
Absolute Maximum Solder Times  
The modules are wash resistant, but are not hermetically sealed. Linx  
recommends wash-free manufacturing; however, the modules can be subjected  
to a wash cycle provided that a drying time is allowed prior to applying electrical  
power to the modules. The drying time should be sufficient to allow any moisture  
that may have migrated into the module to evaporate, thus eliminating the  
potential for shorting damage during power-up or testing. If the wash contains  
contaminants, the performance may be adversely affected, even after drying.  
Hand-Solder Temp. TX +225°C for 10 Seconds  
Hand-Solder Temp. RX +225°C for 10 Seconds  
Recommended Solder Melting Point +180°C  
Reflow Oven: +220°C Max. (See adjoining diagram)  
Page 10  
Page 11  
WIRELESS MADE SIMPLE ®  
U.S. CORPORATE HEADQUARTERS  
LINX TECHNOLOGIES, INC.  
159 ORT LANE  
MERLIN, OR 97532  
PHONE: (541) 471-6256  
FAX: (541) 471-6251  
www.linxtechnologies.com  
Disclaimer  
Linx Technologies is continually striving to improve the quality and function of its products. For this reason,  
we reserve the right to make changes to our products without notice. The information contained in this  
Overview Guide is believed to be accurate as of the time of publication. Specifications are based on  
representative lot samples. Values may vary from lot-to-lot and are not guaranteed. "Typical" parameters can  
and do vary over lots and application. Linx Technologies makes no guarantee, warranty, or representation  
regarding the suitability of any product for use in any specific application. It is the customer's responsibility  
to verify the suitability of the part for the intended application. NO LINX PRODUCT IS INTENDED FOR USE  
IN ANY APPLICATION WHERE THE SAFETY OF LIFE OR PROPERTY IS AT RISK.  
Linx Technologies DISCLAIMS ALL WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A  
PARTICULAR PURPOSE. IN NO EVENT SHALL LINX TECHNOLOGIES BE LIABLE FOR ANY OF  
CUSTOMER'S INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING IN ANY WAY FROM ANY DEFECTIVE  
OR NON-CONFORMING PRODUCTS OR FOR ANY OTHER BREACH OF CONTRACT BY LINX  
TECHNOLOGIES. The limitations on Linx Technologies' liability are applicable to any and all claims or  
theories of recovery asserted by Customer, including, without limitation, breach of contract, breach of  
warranty, strict liability, or negligence. Customer assumes all liability (including, without limitation, liability  
for injury to person or property, economic loss, or business interruption) for all claims, including claims  
from third parties, arising from the use of the Products. The Customer will indemnify, defend, protect, and  
hold harmless Linx Technologies and its officers, employees, subsidiaries, affiliates, distributors, and  
representatives from and against all claims, damages, actions, suits, proceedings, demands, assessments,  
adjustments, costs, and expenses incurred by Linx Technologies as a result of or arising from any Products  
sold by Linx Technologies to Customer. Under no conditions will Linx Technologies be responsible for  
losses arising from the use or failure of the device in any application, other than the repair, replacement, or  
refund limited to the original product purchase price. Devices described in this publication may contain  
proprietary, patented, or copyrighted techniques, components, or materials. Under no circumstances shall  
any user be conveyed any license or right to the use or ownership of such items.  
© 2008 by Linx Technologies, Inc. The stylized Linx logo,  
Linx, “Wireless Made Simple”, CipherLinx, and the stylized  
CL logo are the trademarks of Linx Technologies, Inc.  
Printed in U.S.A.  

相关型号:

BBA-519-A

GENERAL-PURPOSE BROADBAND RF AMPLIFIER DATA GUIDE
ETC

BBA0000001

OSC XO 100MHZ 3.3V SMD
ETC

BBA00010666

CONN SSL SKT CONT 20-22AWG CRIMP
AMPHENOL

BBA00010667

CONN SSL PIN CONT 20-22AWG CRIMP
AMPHENOL

BBA0070002

OSC XO 100MHZ 3.3V SMD
ETC

BBA02

40-6000 MHz BroadBand AMP
BEREX

BBA02_18

40-6000 MHz BroadBand AMP
BEREX

BBA0670001

OSC XO 106.25MHZ 3.3V SMD
ETC

BBA2500010

OSC XO 125MHZ 3.3V SMD
ETC

BBA3270001

OSC XO 132.8125MHZ 3.3V SMD
ETC

BBA3300011

OSC XO 133.33MHZ 3.3V SMD
ETC

BBA5000001

OSC XO 150MHZ 3.3V SMD
ETC