BB-MDR-100-48 [ETC]

AC/DC CONVERTER 48V 96W;
BB-MDR-100-48
型号: BB-MDR-100-48
厂家: ETC    ETC
描述:

AC/DC CONVERTER 48V 96W

文件: 总2页 (文件大小:368K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
96W Single Output Industrial DIN Rail Power Supply  
MDR-100 series  
Features :  
Universal AC input / Full range  
Protections: Short circuit / Overload / Over voltage / Over temperature  
ZCS/ZVS technology to reduce power dissipation  
Cooling by free air convection  
Can be installed on DIN rail TS-35/7.5 or 15  
DC OK relay contact  
No load power consumption<1W  
LED indicator for power on  
100% full load burn-in test  
3 years warranty  
..  
SPECIFICATION  
MODEL  
MDR-100-12  
MDR-100-24  
MDR-100-48  
DC VOLTAGE  
12V  
24V  
48V  
RATED CURRENT  
CURRENT RANGE  
RATED POWER  
7.5A  
4A  
2A  
0 ~ 7.5A  
90W  
0 ~ 4A  
0 ~ 2A  
96W  
96W  
RIPPLE & NOISE (max.) Note.2 120mVp-p  
150mVp-p  
200mVp-p  
48 ~ 56V  
1.0%  
OUTPUT  
VOLTAGE ADJ. RANGE  
VOLTAGE TOLERANCE Note.3  
LINE REGULATION  
12 ~ 15V  
1.0%  
24 ~ 30V  
1.0%  
1.0%  
1.0%  
1.0%  
1.0%  
LOAD REGULATION  
1.0%  
1.0%  
SETUP, RISE TIME  
Note.5 3000ms, 50ms/230VAC  
3000ms, 50ms/115VAC at full load  
HOLD UP TIME (Typ.)  
VOLTAGE RANGE  
50ms/230VAC  
Note.6 85 ~ 264VAC  
47 ~ 63Hz  
20ms/115VAC at full load  
120 ~ 370VDC  
FREQUENCY RANGE  
POWER FACTOR (Typ.)  
EFFICIENCY (Typ.)  
PF0.95/230VAC  
83%  
PF0.98/115VAC at full load  
INPUT  
86%  
87%  
AC CURRENT (Typ.)  
INRUSH CURRENT (Typ.)  
LEAKAGE CURRENT  
1.3A/115VAC  
0.8A/230VAC  
COLD START 30A/115VAC  
60A/230VAC  
<1mA / 240VAC  
105 ~ 150% rated output power  
OVERLOAD  
Protection type : Constant current limiting, recovers automatically after fault condition is removed  
15.6 ~ 18V 31.2 ~ 36V 57.6 ~ 64.8V  
PROTECTION  
OVER VOLTAGE  
Protection type : Shut down o/p voltage, re-power on to recover  
Shut down o/p voltage, auto-recovery or re-power on to recover  
Relay contact rating(max.): 30V/1A resistive  
-10 ~ +60(Refer to "Derating Curve")  
20 ~ 90% RH non-condensing  
OVER TEMPERATURE  
DC OK SIGNAL  
FUNCTION  
WORKING TEMP.  
WORKING HUMIDITY  
ENVIRONMENT STORAGE TEMP., HUMIDITY  
TEMP. COEFFICIENT  
-40 ~ +85, 10 ~ 95% RH  
0.03%/(0 ~ 50)  
Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6  
UL508, TUV EN60950-1 approved  
VIBRATION  
SAFETY STANDARDS  
WITHSTAND VOLTAGE  
SAFETY &  
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC  
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25/ 70% RH  
ISOLATION RESISTANCE  
EMC EMISSION  
EMC IMMUNITY  
MTBF  
EMC  
(Note 4)  
Compliance to EN55011, EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3  
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A  
346K hrs min. MIL-HDBK-217F (25)  
55*90*100mm (W*H*D)  
OTHERS  
NOTE  
DIMENSION  
0.42Kg; 30pcs/13.6Kg/0.82CUFT  
PACKING  
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25of ambient temperature.  
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.  
3. Tolerance : includes set up tolerance, line regulation and load regulation.  
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets  
EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”  
(as available on http://www.meanwell.com)  
5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.  
6. Deating maybe needed under low input voltages, please check the derating curve for more detail.  
File Name:MDR-100-SPEC 2017-07-07  
orders@advantech-bb.com  
support@advantech-bb.com  
Corporate Headquarters: 707 Dayton Road, PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104  
European Office: Westlink Commercial Park, Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445  
96W Single Output Industrial DIN Rail Power Supply  
MDR-100 series  
Mechanical Specification  
Case No.973A  
Unit:mm  
35  
55  
5
100  
5
5
5 5  
+V +V -V -V  
DC OK  
DC OK  
+
+V ADJ  
N
L
7.5 7.5  
Install DIN rail TS35/7.5 or TS35/15  
Block Diagram  
DC OK  
EMI FILTER  
&
RECTIFIERS  
RECTIFIERS  
+V  
-V  
PFC  
CIRCUIT  
POWER  
I/P  
FG  
&
SWITCHING  
FILTER  
O.C.P.  
O.L.P.  
DETECTION  
CIRCUIT  
PFC  
CONTROL  
PWM  
CONTROL  
O.V.P.  
O.T.P.  
DC OK Relay Contact  
Contact Close  
Contact Open  
PSU turns on / DC OK.  
PSU turns off / DC Fail.  
Contact Ratings (max.) 30V/1A resistive load.  
Derating Curve  
Output Derating VS Input Voltage  
100  
90  
100  
80  
80  
70  
60  
40  
60  
50  
40  
20  
-10  
0
10  
20  
30  
40  
50  
60  
70 (VERTICAL)  
85 95 100 115 120 140 160 180 200 220 240 264  
AMBIENT TEMPERATURE ()  
INPUT VOLTAGE (VAC) 60Hz  
File Name:MDR-100-SPEC 2017-07-07  
orders@advantech-bb.com  
support@advantech-bb.com  
Corporate Headquarters: 707 Dayton Road, PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104  
European Office: Westlink Commercial Park, Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445  

相关型号:

BB-MDR-60-24

AC/DC CONVERTER 24V 60W
ETC

BB-MDR-60-48

AC/DC CONVERTER 48V 60W
ETC

BB-MESR321

ROUTER 3G HSPA ETH
ETC

BB-MESR424D

ROUTER 4G LTE NA MULTI CARRIER
ETC

BB-MESR424T

ROUTER 4G LTE NA MULTI CARRIER
ETC

BB-MESR901

ETHERNET TO SER RS-232/422/485
ETC

BB-MESR902T

SERIAL DEVICE SERVER 2-PORT
ETC

BB-MESR921

MODBUS DIN ESS, 1 PORT, CU
ETC

BB-MESR921-MT

MODBUS DIN ESS, 1 PORT, CU
ETC

BB-MESR922T

BRIDGE WIFI DUAL BAND
ETC

BB-MESR922T-MC

ETHERNET TO SER RS-232/422/485
ETC

BB-MESR922T-MT

MODBUS DIN ESS, 2 PORT, MU LTI S
ETC