RUGGED AC/DC INPUT 150W POWER SUPPLY; 坚固的AC / DC输入150W电源![ACE-716](http://pdffile.icpdf.com/pdf1/p00022/img/icpdf/ACE-716_106703_icpdf.jpg)
型号: | ACE-716 |
厂家: | ![]() |
描述: | RUGGED AC/DC INPUT 150W POWER SUPPLY |
文件: | 总1页 (文件大小:95K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
w w w .lo ca m a t io n .co m
Rugged AC/DC Input 150W Power Supply
ACE-716
● Hi-pot isolation :
— 4300V DC, input to output for one minute
— 2200V DC, input to ground for one minute
● MTBF :
PFC
— ACE-716A : 188,800 hours
— ACE-716T : 212,050 hours
— ACE-716C : 187,490 hours
● Safety : Meets UL 478, 1012, 1950;
CSA 22.2 No. 234, VDE EN 60950
● EMI :
— Meets FCC docket 20780 curve "A",
EN50081-2 : CISPR22 "A"
— Harmonic EN 61000-3-2 for ACE-716AP
● EMS Standard (Designed to meet the
following limits) :
— EN 50082-2
— IEC 801-1 8KV (Air Discharge) criteria
B (ACE-716A/716AP)
— IEC 801-3, 10V/M criteria A
— IEC 801-4, 2KV criteria B
(ACE-716A/716AP)
BAUART
GEPR FT
T V Rheinland
¤
— IEC 801-5, 2KV criteria B
(ACE-716A/716AP)
● Built-in cooling fan
SPECIFICATIONS
● Input Table :
● Operating Temperature : -20o ~ 70oC
(Derating curve will occur 50o ~ 70oC)
● Storage Temperature : -20o ~ 85oC
● Dimensions : 97(W) x 40.5(H) x 198(D)mm;
(3.8" x 1.6" x 7.8")
Model
Input Range
Input Current
ACE-716A/716AP
85~135V AC or
180~265V AC, 47~440Hz
-36 ~ -72V DC
4A@115V AC or
2A@230V AC
6A@-48V DC
12A@+24V DC
ACE-716T
ACE-716C
+19 ~ +30V DC
● Output Table (at 50oC) :
ORDERING INFORMATION
Rated Load
+5V +12V -5V -12V +5V +12V -5V -12V
18A 4A 0.5A 1A 25A 10A 1A 1A
18A 4A 0.5A 1A 25A 10A 1A 1.5A
18A 4A 0.5A 1A 25A 10A 1A 1.5A
Max. Output
Model
ACE-716AP
Rugged AC input 150W PFC power supply
ACE-716A/716AP
ACE-716T
ACE-716C
ACE-716A
Rugged AC input 150W power supply
ACE-716T
Rugged 48V DC input 150W power supply
● Inrush Current (ACE-716A/716AP) : Not exceed 15A@115V AC
or 30A@230V AC
ACE-716C
● Ripple and Noise : Less than 100mV
Rugged 24V DC input 150W power supply
● Line Regulation : The line regulation for each outputs are less
than –1%, while measuring at rated loading and –10% of input
voltage changing
● Load Regulation :
DIMENSIONS
— ACE-716A/716AP : Less than –3%@–5V and -12V, –6%@+12V
— ACE-716T/C : Less than –1%@–5V and -12V, –4%@+12V
● Efficiency :
— ACE-716A/716AP : Higher than 75%
— ACE-716T/C : Higher than 70%
● Hold-up Time (ACE-716A/716AP) : 20ms (typical)@115V AC
● Altitude : 0 ~ 10,000ft
● Protection : Over voltage protection. The trip point is around
5.9V ~ 7.0V output
● Thermal Protection : Built in 110–5oC thermal switch in HS1
● Vibration : 10 ~ 55Hz at 2G 3min. period, 30 min. along X, Y
and Z axis
● Impact : 10G for 20ms once on each X, Y and Z axis