5903S [ETC]

CIRCUIT PROTECTION; 电路保护
5903S
型号: 5903S
厂家: ETC    ETC
描述:

CIRCUIT PROTECTION
电路保护

电路保护
文件: 总2页 (文件大小:154K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MK Electric - Print Item Information  
ITEM NUMBER: 5504S  
CIRCUIT PROTECTION  
SENTRY  
ENCLOSURES IP30 ENCLOSURE  
CARTON QUANTITY: 1  
5504s  
Metal  
With mounting rail,  
earth terminals and  
moulded front plate  
Four module  
These enclosures will accommodate two or four  
module Sentry RCDs or a combination of Sentry  
modules, excluding contactors.  
Dimensions:  
5504s: 188 x 121 x 74mm  
(width x height x depth)  
Degree of Protection to  
BS EN 60529: 1992  
5504s: IP30  
Precautions must be taken to maintain the IP rating.  
eg. correct use of cable glands and knockouts  
Click here to view the Honeywell privacy statement  
Site designed & developed by viplondon  
http://www.mkelectric.co.uk/products/print.asp?rangeid=1051&itemid=671208/02/2007 13:15:08  
220  
Sentry  
CIRCUIT PROTECTION  
www.mkelectric.co.uk  
Skeleton Units  
Switch  
Disconnectors  
Double Pole  
MCBs  
Single Pole  
Enclosures  
FOR MOUNTING IN A  
MANTEL/CLIFTON TYPE  
ENCLOSURE  
IP65  
WEATHERPROOF  
ENCLOSURE  
TYPE B  
ONE MODULE  
TWO MODULE  
IP30 ENCLOSURE  
6000s  
5502s  
K5592s  
5702s  
5500s  
5903s  
5906s  
6001s  
5704s  
5504s  
5604s  
5560s  
5910s  
5916s  
10  
10  
10  
10  
1
5
5
6000s  
5500s  
5903s  
1
1
1
1
5702s  
5502s  
ACCEPTS 14  
100A 230V  
3A 230V  
WEATHERPROOF  
INSULATED COMPLETE WITH  
MOUNTING RAIL, NEUTRAL  
AND EARTH TERMINALS  
TWO MODULE  
ONE MODULE PRODUCTS  
(1 INTEGRAL NEUTRAL BAR)  
COMPLETE WITH NEUTRAL AND  
EARTH TERMINAL BLOCK  
ACCEPTS UP TO 4 MODULES  
5560s  
63A 230V  
5906s  
6A 230V  
1
6001s  
5910s  
10A 230V  
100A SWITCH DISCONNECTOR  
AND 63A 30mA RCD.  
ACCEPTS A FURTHER 10  
ONE MODULE PRODUCTS  
IN ANY CONFIGURATION OF  
RCD PROTECTED  
K5592s  
5704s  
WEATHERPROOF  
COMPLETE WITH NEUTRAL AND  
EARTH TERMINAL BLOCK  
ACCEPTS UP TO 8 MODULES  
RCBO ENCLOSURE – METAL  
TWO AVAILABLE MODULES  
SUITABLE FOR LIST NOS.  
6932s, 6933s, 6934s, 6935s,  
6936s, 6937s, 6938s  
WITH MOUNTING RAIL,  
EARTH TERMINALS AND  
METAL FRONT PLATE  
5916s  
16A 230V  
Typical applications for enclosures  
AND UNPROTECTED CIRCUITS  
BETWEEN 2/8 AND 8/2  
are house extensions, garages and  
small workshops.  
These enclosures will accommodate  
two or four module Sentry RCDs or  
a combination of Sentry modules,  
excluding contactors.  
1
1
These units are suitable for use in  
most Mantel and Clifton type  
enclosures.  
5504s  
METAL  
WITH MOUNTING RAIL,  
EARTH TERMINALS AND  
MOULDED FRONT PLATE  
FOUR MODULE  
Suitable for installation in Sentry  
Consumer Units and two or four  
module enclosures. Accepts direct  
to busbar or cable-in / cable-out  
connection. Category of duty:  
AC22A for switching of resistive  
and inductive loads.  
Suitable for installation in Sentry  
Consumer Units and two or four  
module enclosures.  
Factory assembled units are available  
for specific installations.  
Positive contact status indication in  
accordance with 16th Edition IEE  
Wiring Regulations  
DIMENSIONS:  
WIDTH HEIGHT DEPTH  
DIMENSIONS:  
5702S: 200 x 123  
5704S: 200 x 195  
5502S: 149 x 76  
5504S: 188 x 121  
5604S: 160 x 85  
K5592s:185 x 119  
x
x
x
x
x
x
112mm  
112mm  
76mm  
74mm  
68mm  
66mm  
(537-02-03 and 537-03-02)  
5604s  
INSULATED  
WITH MOUNTING RAIL,  
Positive contact status indication in  
accordance with 16th Edition IEE  
Wiring Regulations  
WIDTH HEIGHT DEPTH  
6000s: 222 x 333  
6001s: 222 x 333  
DIMENSIONS:  
83 x 18 x 74mm  
x
x
90mm  
90mm  
(537-02-03 and 537-03-02)  
CABLE CAPACITY:  
TWO INTEGRAL BLANKING PLATES  
AND TAMPER-PROOFING  
COMPONENTS  
3, 6, 10, 16A: 35mm2  
Degree of Protection to  
BS EN 60529: 1992 IP30  
DIMENSIONS:  
81 x 36 x 76mm  
Short-circuit breaking capacity: 6KA  
BS EN 60898: 1991  
Precautions must be taken to maintain  
the IP rating, eg. correct use of cable  
glands and knockouts.  
FOUR MODULE  
K5592s suitable for Sentry Single  
Module RCBO.  
Degree of Protection to  
BS EN 60529: 1992  
5702s: IP65  
5704s: IP65  
5502s: IP30  
CABLE CAPACITY:  
50mm2  
BS EN 60947-3: 1992  
BS EN 60439-3: 1994  
Precautions must be taken to  
maintain the IP rating, eg. correct  
use of cable glands and knockouts  
5504s: IP30  
5604s: IP30  
K5592s: IP30  
IP65 enclosures to EN 60670  

相关型号:

5904-1-S-02-A

Press-Fit Firecracker Reed Sensor
LITTELFUSE

5904-1-S-02-E

Press-Fit Firecracker Reed Sensor
LITTELFUSE

5904-1-S-02-F

Press-Fit Firecracker Reed Sensor
LITTELFUSE

5904-1-T-02-A

Press-Fit Firecracker Reed Sensor
LITTELFUSE

5904-1-T-02-E

Press-Fit Firecracker Reed Sensor
LITTELFUSE

5904-1-T-02-F

Press-Fit Firecracker Reed Sensor
LITTELFUSE

5904-1-U-02-A

Press-Fit Firecracker Reed Sensor
LITTELFUSE

5904-1-U-02-E

Press-Fit Firecracker Reed Sensor
LITTELFUSE

5904-1-U-02-F

Press-Fit Firecracker Reed Sensor
LITTELFUSE

5904-3-S-02-A

Press-Fit Firecracker Reed Sensor
LITTELFUSE

5904-3-S-02-E

Press-Fit Firecracker Reed Sensor
LITTELFUSE

5904-3-S-02-F

Press-Fit Firecracker Reed Sensor
LITTELFUSE