543945010U500 [ETC]
20 AWG solid bare copper conductor, foam polyethylene insulation, bare copper braid shield, PVC jacket, sequential footage marking every two feet.;型号: | 543945010U500 |
厂家: | ETC |
描述: | 20 AWG solid bare copper conductor, foam polyethylene insulation, bare copper braid shield, PVC jacket, sequential footage marking every two feet. 连接器 连接器支架 |
文件: | 总3页 (文件大小:24K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
543945 Coax - Surveillance and CCTV Applications
For more information please
call
1-800-Belden1
See Put-ups and Colors
Description:
20 AWG solid bare copper conductor, foam polyethylene insulation, bare copper braid shield, PVC jacket, sequential footage marking every
two feet.
SUITABLE APPLICATIONS:
Suitable Applications
Analog Video/CCTV Coax.
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Coax
RG Type
1
59/U
Series Type
Series 59
20
AWG
Stranding
Solid
Conductor Diameter
Conductor Material
.032 in.
BC - Bare Copper
INSULATION:
Insulation Material
Insulation Diameter
Gas-injected FPE - Foam Polyethylene
.145 in.
OUTER SHIELD:
Outer Shield Type
Braid
Outer Shield Material
Outer Shield %Coverage
BC - Bare Copper
95 %
OUTER JACKET:
Outer Jacket Material
PVC - Polyvinyl Chloride
.232 in.
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter
MECHANICAL CHARACTERISTICS:
Operating Temperature Range
UL Temperature Rating
-30°C To +75°C
75°C
Bulk Cable Weight
29 lbs/1000 ft.
Max. Recommended Pulling Tension
57 lbs.
Page 1 of 3
543945 Coax - Surveillance and CCTV Applications
Min. Bend Radius (Install)
2.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification
NEC Articles
CM
800
CEC/C(UL) Specification
EU CE Mark (Y/N)
CM
Yes
EU RoHS Compliant (Y/N)
EU RoHS Compliance Date (mm/dd/yyyy):
Yes
01/01/2004
FLAME TEST:
UL Flame Test
UL1685 UL Loading
FT1
C(UL) Flame Test
SUITABILITY:
Suitability - Indoor
Suitability - Outdoor
Suitability - Aerial
Yes
Yes - Black only
Yes - Black only
PLENUM/NON-PLENUM:
Plenum (Y/N)
N
ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance
Nom. Inductance
75 Ohms
.097 µH/ft
Nom. Capacitance Conductor to Shield
Nominal Velocity of Propagation
Nominal Delay
16.3 pF/ft
83 %
1.21 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C
Nominal Outer Shield DC Resistance @ 20 Deg.C
Nom. Attenuation :
10.0 Ohms/1000 ft
3.5 Ohms/1000 ft
Description
Frequency (MHz)
Start Frequency (MHz) Stop Frequency (MHz)
Nom. Attenuation
(dB/100 ft.)
1
.30
5
.65
10
.90
50
1.90
2.60
3.60
5.00
7.00
8.00
8.50
100
200
400
700
900
1000
Max. Operating Voltage - UL
300 V RMS
Page 2 of 3
543945 Coax - Surveillance and CCTV Applications
PUT-UPS AND COLORS:
Item
Description
Put-Up (ft.)
Ship Weight (lbs.)
Jacket Color
Notes
543945 0091000
RG-59/U COAX
RG-59/U COAX
RG-59/U COAX
RG-59/U COAX
RG-59/U COAX
RG-59/U COAX
RG-59/U COAX
RG-59/U COAX
1000
32
WHITE
C
543945 009500
500
16
31
16
32
16
31
16
WHITE
WHITE
WHITE
BLACK
BLACK
BLACK
BLACK
543945 009U1000
543945 009U500
543945 0101000
543945 010500
U1000
U500
1000
500
C
C
543945 010U1000
543945 010U500
U1000
U500
C = CRATE REEL PUT-UP.
Revision Number: 1
Revision Date: 09-29-2005
© Copyright 2006 Belden, Inc
All Rights Reserved.
Although Belden ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication, information and
specifications described herein are subject to error or omission and to change without notice, and the listing of such information and
specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described
herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with the following environmental regulations: California Proposition 65 Consent Judgment
For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS (Directive 2002/95/EC, 27-Jan-
2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our Distributor's inventory. EU
ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR (Directive 2003/11/EC, 6-Feb-
2003). The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the
Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its publication. The information
provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product
itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory
information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations
based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3
相关型号:
©2020 ICPDF网 联系我们和版权申明