4561-9024 [ETC]

LEISSTUNGSRELAIS PCB 16A 24VDC ; LEISSTUNGSRELAIS PCB 16A 24VDC\n
4561-9024
型号: 4561-9024
厂家: ETC    ETC
描述:

LEISSTUNGSRELAIS PCB 16A 24VDC
LEISSTUNGSRELAIS PCB 16A 24VDC\n

PC
文件: 总4页 (文件大小:70K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
4 5 Se rie s - Min ia tu re P.C.B. Re la y s  
1 6 A + Fa sto n 2 5 0  
Features include:  
• Miniature P.C.B. Faston 250 mount relay  
• DC coil  
• 8 mm between coil and contacts in accordance with VDE 0700  
• Sealed, with removable pip to avoid ozone accumulation when relay is operating  
NO contact version (supplied as standard)  
• Approvals (accoding to type): CSA, cUL, IMQ, SEMKO, SEV, VDE  
WHITE  
GOODS  
ELECTRONIC  
APPLIANCES  
AIR  
CONDITIONING  
3 9  
4 5 Se rie s - Min ia tu re P.C.B. Re la y s  
1 6 A + Fa sto n 2 5 0  
4 5 .6 1  
C
MIN IATURE P.C.B. FASTO N 2 5 0 PO W ER RELAY 1 6 A  
TYPE 4 5 .6 1 1 NO (SPST-NO) 5 mm pinning  
- Tin plated connections for P.C.B.  
- Standard contact material: AgNi + AgCdO  
- Ordering information: see page 42  
28.9  
copper side view  
11  
14  
14  
1.5  
28.9  
6.3  
1.5  
11  
A1  
A2  
A1  
A2  
5
32.5  
3
0.4  
1
1
40.5  
TECHNICAL DATA  
DIELECTRIC STRENGTH  
tested at leakage current  
between coil and contacts  
4,000 V  
1,000 V  
10 mA for 1 min at 50 Hz  
between open contacts  
SURGE TEST (1.2/ 50 µs) VOLTAGE BETWEEN COIL AND CONTACTS 6,000 V  
ISOLATION RESISTANCE  
ISOLATION GROUP  
20 · 103 MΩ  
C 250  
ISOLATION DISTANCES  
MAXIMUM SWITCHING FREQUENCY  
- without load  
8 mm between coil and contacts according to VDE 0700  
36,000 cycles/ h  
600 cycles/ h  
(–40 ... +125)°C  
20 · 106 cycles  
IP 67  
- at rated load  
AMBIENT TEMPERATURE  
MECHANICAL LIFE  
PROTECTION CATEGORY OF ENCLOSURES  
OPERATE AND RELEASE TIME:  
- pick-up time (from 0 to UN)  
10 ms (including contact bounce)  
TYPE OF DUTY  
continuous  
DIELECTRIC TEST  
2
TYPE OF RELAY  
all-or-nothing  
4 0  
4 5 Se rie s - Min ia tu re P.C.B. Re la y s  
1 6 A + Fa sto n 2 5 0  
CONTACT SPECIFICATIONS  
RATED CURRENT  
16 A  
MAXIMUM PEAK CURRENT  
NOMINAL RATE IN AC1  
NOMINAL RATE IN AC15  
RATED VOLTAGE  
30 A  
4,000 VA  
750 VA  
250 V AC  
MAXIMUM SWITCHING VOLTAGE  
BREAKING CAPACITY IN DC1  
SINGLE PHASE HP MOTOR RATING  
CONTACT RESISTANCE: - initial  
ELECTRICAL LIFE  
400 V AC  
see diagram H 45  
0.55 kW/ 0.8 HP  
50 mΩ  
100 · 103 cycles, (+85°C)  
5 · 104 cycles, (+125°C)  
500 mW (10 V/ 5 mA)  
AgNi + AgCdO  
MINIMUM SWITCHING LOAD  
STANDARD CONTACT MATERIAL  
F 4 5  
H 4 5  
107  
106  
105  
20  
10  
6
4
2
1
0.6  
0.4  
0.2  
0.1  
20  
60  
100  
DC VOLTAGE (V)  
Breaking capacity for DC1 load at 600 cycles/ h.  
140  
180  
220  
0
1
2
3
4
LOAD (kVA)  
Contact life AC1 load at 900 cycles/ h (+85°C).  
K 4 5  
1
0.8  
k
0.6  
0.4  
1
0.8  
0.6  
0.4  
0.2  
COS ϕ  
Load reduction factor vs cos ϕ.  
4 1  
4 5 Se rie s - Min ia tu re P.C.B. Re la y s  
1 6 A + Fa sto n 2 5 0  
COIL SPECIFICATION  
VERSIONS:  
DC - direct current  
RATED POWER  
0.65 W  
MINIMUM POWER  
0.35 W  
OPERATING RANGE  
(0.73 ... 1.5) UN  
0.4 UN  
0.1 UN  
180 A  
HOLDING VOLTAGE  
MUST DROP-OUT VOLTAGE  
NOMINAL MAGNETOMOTIVE FORCE  
THERMAL INSULATION CLASS OF WIRE  
THERMAL RESISTANCE  
F (+155°C)  
52°C/ W  
CONDUCTED DISTURBANCE IMMUNITY  
BURST (acc. to EN 61000 - 4 - 4) level 4 (4 kV)  
SURGE (acc. to EN 61000 - 4 - 5) level 3 (2 kV)  
DC VERSIO N DATA  
R values relate to +20°C. Tolerance of R and I values: ± 10%.  
Nominal  
voltage  
UN  
Resistance  
Nominal coil  
absorption  
Operating range  
Umin  
Umax  
V
R
I
V
6
V
mA  
109  
55  
4.4  
9
55  
12  
24  
48  
60  
110  
8.8  
17.5  
35  
18  
36  
72  
90  
165  
220  
900  
27  
3,500  
5,500  
18,000  
14  
43.8  
80.3  
11  
6.1  
R 4 5  
S 4 5  
2.5  
80  
70  
60  
50  
40  
Umin  
UN  
1.5 UN  
1
2
1.5  
1
1.2 UN  
UN  
30  
20  
2
0.73 UN  
0.5  
10  
-20 -10  
0
10 20 30 40 50 60 70 80 90  
AMBIENT TEMPERATURE (°C)  
10  
20  
30  
40  
50  
60  
HEATING TIME (min)  
Temperature rise "t " vs applied voltage. DC coils.  
Operating range (DC type) vs ambient temperature  
1 - Max coil voltage permitted  
2 - Min pick-up voltage with coil at ambient temperature  
ORDERING INFORMATION  
Example: 45 series for P.C.B. + Faston 250, 1 NO (SPST-NO) contact, coil rated 12 V DC.  
6
1
9
0 1 2  
0
0
0
4 5  
0
Co il ra te d vo lta g e  
Se rie s  
Co il ve rsio n  
N o . o f p o le s  
9 = DC  
006 =  
6 V  
1 = 1 NO (SPST-NO)  
012 = 12 V  
024 = 24 V  
048 = 48 V  
060 = 60 V  
110 = 110 V  
Ty p e  
6 = P.C.B. + Faston 250  
4 2  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9122E

500-kHz Half-Bridge DC/DC Controller with Integrated Secondary Synchronous Rectification Drivers

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY