Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G  
Contactors  
Contactors  
Bulletin 100-M, 100-C,  
CAB6  
• Bulletin 100-M  
2.2 … 5.5 kW  
• Bulletin 100-C  
4 … 45 kW  
Pages  
4-9 … 4-64  
4
• Bulletin CAB6  
45 … 220 kW  
Bulletin 100S, 104S  
Safety Contactors  
• Bulletin 100S, 104S  
4 … 45 kW  
w
e
N
Bulletin 100-G  
Contactors  
Pages  
4-65 … 4-78  
• Bulletin 100-G  
315 … 710 kW  
Contactor Overview  
AC-3 / 400 VAC  
100-G (550…1200 A)  
CAB6 (85…420 A)  
100-C (9…85 A)  
100-M (5…12 A)  
[kW] 2.2  
4
5.5  
45  
220  
710  
Rockwell Automation  
4-1  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G  
Contactors  
Overview - Bulletin 100-M  
Connection module (Eco starter)  
for circuit breakers 140M  
Auxiliary contact block  
2 poles  
Suppressor module  
RC, Diode,  
Auxiliary contact block  
4 poles  
4
Miniature Contactor  
100-M12N…  
Varistor  
Connecting kit  
Timer  
for pick-up delay  
Timer for Y-control  
switching delay  
Latched miniature contactor  
100-ML09N…  
Mechanical  
interlock  
Reversing contactor  
104-M  
4-2  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G  
Contactors  
Overview - Bulletin 100-M  
Minimum Space Requirements for Accessories  
Auxiliary contact blocks and timers can be mounted onto the contactor  
without requiring additional panel space.  
4
Positive Guidance of the Contacts  
Positive guidance of the contacts according to IEC 60947-5-1 is given  
when it is ensured, that N.C. and N.O. contacts can never be closed at  
the same time. Therefore a minimum opening distance of 0.5 mm is  
prescribed in the event of failure. All contacts in the basic device are  
positively guided as well as the normally closed contacts in the auxiliary  
contact block except Bulletin 700-MB bifurcated contacts. This permits  
use within safety controls.  
High Contact Reliability  
Bulletin 100-M Miniature Contactors are rated for extra-low voltage. In  
addition to the isolation of the contact housing, high contact reliability is  
ensured by the special design of the auxiliary contacts:  
• cross-stamped in the main contactor  
• in the auxiliary contact block and in the bifurcated contacts (see chap-  
ter 8, Bulletin 700-M timers), H-contact bridges with constant sliding  
rolling motion and 4 multiple current path.  
Rockwell Automation  
4-3  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G  
Contactors  
Overview - Bulletin 100-C  
Connection module  
for circuit breakers 140M  
Solid-State timing module  
for Y-control  
Interface  
4
switching delay  
Solid-State timing module  
pick-up delay  
Connection set  
Suppressor module  
RC, Diode, Varistor  
Contactor  
100-C30, C37  
Mechanical  
interlock  
Contactor  
100-C09…C23  
Contactor  
100-C60…C85  
Contactor  
100-C43  
Pneumatic  
timing module  
Auxiliary contact blocks  
for side mounting  
1- and 2-pole  
Mechanical  
latch  
Auxiliary contact blocks  
for front mounting  
2-pole  
Auxiliary contact blocks  
for front mounting  
4-pole  
4-4  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G  
Contactors  
Overview - Bulletin 100-C, 100S-C  
Compact design  
Bulletin 100-C contactors switch more power and use less panel space. Despite  
their small dimensions, they are powerful enough for use with the high starting  
currents of today’s modern motors.  
45 mm  
9 A, 12 A,  
16 A, 23 A  
45 mm  
30 A,  
37 A  
54 mm  
43 A  
72 mm  
60 A, 72 A,  
85 A  
4
(AC-3 at 400/415 V)  
Bulletin 100-C contactors for good connections  
Two separate power connections per pole offer ease of wiring and high connection  
reliability. The modern connection technology used by Bulletin 100-C contactors  
saves both time and money.  
Coil always positioned correctly  
The dual connection technology always positions the coil connection for optimal  
accessibility, whetherbelow(onstarterswithcircuitbreakers), orabove(onstarters  
using the revolutionary Bulletin 193-E Electronic Overload relay). Space- and cost-  
saving coil modules (interface devices, protection elements, Electronic timers) can  
always be added. When ordering, select the desired position of the coil connec-  
tions. The position of the coil connections can also be adapted locally within sec-  
onds, using simple tools.  
Uniform accessories for the entire line of contactors  
AllBulletin100-Caccessories canbeusedwithallcontactor sizes.Themechanical  
interlock with integrated interlock contacts can be used alone to interlock the small-  
est AC contactor with the largest.  
Bulletin 100-C contactors for highest security  
Bulletin 100-C contactors are rated for high personal protection and functional  
security. The safety package consists of amongst other things  
finger and back of hand accidental contact protection.  
• Secure isolation of electric circuits  
• Positively guided contacts  
• Cover to prevent manual operation.  
Comprehensive Safety for Operating Personnel and the Machine  
The safety of both operators and machinery becomes more and more important.  
Electrical controls can play an important contribution to safety. Various rules and  
standards define the components and systems that are used in safety applications.  
• Positively guided contacts according to IEC 947-5-1  
• Fixed coupling of contactor and auxiliary contact block  
• Protection against unintended actuation  
• Auxiliary contacts that are electronically compatible according to DIN 19240  
Positive Guidance of the Contacts  
Positive guidance of contacts according to IEC 60947-5-1 is given when it  
is ensured, that N.C. and N.O. contacts are never able to be closed at the same  
time. Therefore a minimum opening distance of 0.5 mm is prescribed in the event  
of failure. All contacts in the basic device are positively guided as well as the  
normally closed contacts in the auxiliary contact block. The contacts in the basic  
deviceaswellasintheauxiliarycontactblocksareguidedrestricted. Therestricted  
guidance also applies between basic device and accessories.  
Rockwell Automation  
4-5  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G  
Contactors  
Overview - Bulletin CAB6  
Terminal block  
Connection set  
Star Bridge  
4
Contactor  
CAB6-85…  
Auxiliary contact block  
Contactor  
CAB6-210…  
Mechanical  
interlock  
Auxiliary contact blocks  
Suppressor module  
RC, Diode, Varistor  
Easy-to-wire coil connections  
Interface integrated with CAB6-105-EI  
Threaded connections  
Max. 2 auxiliary contacts per  
side, left- and right-side mounted  
Completely enclosed arcing chamber  
Isolated switching position inhibits  
manual operation  
Safety lock for arcing chamber and  
contact holders  
4-6  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G  
Contactors  
Overview - Bulletin CAB6  
Bulletin CAB6 Contactors with electronically controlled Coil Mechanism  
Bulletin CAB6 contactors are equipped with electronically controlled coil mechanisms and integrated interface starting from size  
CAB6-105-EI. Size CAB6-85 is equipped with conventional coils and sizes CAB6-105 and CAB6-140 can be equipped with either  
conventional or electronic coils. Contactors with electronic coils are characterised by the -El suffix. By offering control options, a  
multitude of possibilities are at the user's disposal:  
• Integrated interface  
The factory supplied CAB6-EI range features an interface module that can be  
activated and deactivated via an externally accessible jumper unit. With the  
interface, the contactor can be addressed directly by a 24 V DC signal from a  
programmable logic controller. The max. allowable current of the interface is 15  
mA (DIN VDE 19240). The Interface input is separated from the coil circuit by  
photoelectric.  
4
• Protective circuit included  
All EI-type contactors have a protective circuit as standard.  
• Low pick-up and holding power  
When compared with conventional contactors, the current requirement is sub-  
stantially lowered by the construction of the contactor, particularly via the elec-  
tronic control.  
• Wide voltage range  
Despite the wide voltage range (e.g., 208...277 V AC) the min./max. values of  
the IEC tolerances are kept between -0.85 and +1.1.  
• Compact dimensions  
New, compact construction solutions and the application of electronics substan-  
tially reduces the dimensions. Two housing sizes cover the entire range from  
85...420 A (AC-3). Simple and efficient wiring is ensured by the identical con-  
nection height of the main pole on both housing sizes.  
Bulletin CAB6 contactors can be mechanically interlocked, without needing ad-  
ditional mounting space.  
CAB6-85…170  
CAB6-210…420  
• Defined on- and off- points  
Electronic control guarantees defined points of switching on and off, thus pre-  
venting chatter and damage to the contactor.  
• Environmentally friendly  
Construction and contact materials do not contain cadmium, asbestos or PCBs  
and can be recycled at the end of the contactor life. Most plastic parts are char-  
acterised according to DIN 54840.  
• Frame terminal blocks  
Go safe! Contact protection is fulfilled by attachable terminal covers according  
to DIN VDE 0106 and VBG 4. By using framework terminal blocks the contactor  
automatically becomes finger-safe per IP20.  
Rockwell Automation  
4-7  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G  
Contactors  
Overview - Bulletin 100-G / CA 5  
Supply module  
Contactor  
Mechanical interlock  
100-G / CA 5  
(horizontal construction)  
Auxiliary contact block  
4
Mechanical interlock  
(vertical construction)  
Fourth pole  
Coil sets  
Mechanical latch  
Good reasons to select Rockwell  
Automation contactors  
• Allen-Bradley contactors are built for a global marketplace  
and fulfill all applicable IEC 947 requirements.  
• Worldwide acceptance and high stock availability in all  
countries increases security for the user.  
• A wide range of accessories (e.g., auxiliary contact blocks,  
interfaces, control and timing modules) make contactors  
ideal and economical building blocks for individual  
control needs.  
4-8  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Bulletin 100-M  
Miniature Contactors  
Bulletin 100-M  
2.2 … 5.5 kW (5 … 12 A)  
4
Bulletin 100-C, CAB6  
Contactors  
Bulletin 100-C  
4 … 45 kW (9 … 85 A)  
Bulletin 104-C  
4 … 45 kW (9 … 85 A)  
Bulletin CAB6  
45 … 220 kW (85 … 420 A)  
Bulletin 100S, 104S  
Safety Contactors  
Bulletin 100S-C  
4 … 45 kW (9 … 85 A)  
Bulletin 104S-C  
4 … 45 kW (9 … 85 A)  
Table of Contents  
Description  
Page Description  
Page  
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2 Specifications  
Product Selection  
Performance Data / Characteristics . . . . . . . . . . . . . . . . . . . . .4-36  
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-44  
Standards and Approvals. . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-49  
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-51  
Permissible Switching Rate . . . . . . . . . . . . . . . . . . . . . . . . . . .4-57  
AC Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10  
DC Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12  
Special Versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14  
Reversing Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16  
Safety Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-61  
Accessories  
Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24  
Mounting Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-31  
Labelling Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33  
Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33  
Rockwell Automation  
4-9  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Product Selection  
3-pole Contactors  
AC control  
3 main contacts  
100-M  
AC-1  
100-C  
100-C  
CAB6  
4
Auxiliary  
Contacts  
Integrated  
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)  
(40 °C)  
[kW] ➊  
[A]  
Cat. No.  
PQ  
[A]  
230 V 400 / 415 V 500 V 690 V 230 V 400 / 415 V 500 V 690 V  
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
100-M05N  
100-M05N  
100-M09N  
100-M09N  
100-M12N  
100-M12N  
100-C09  
100-C09  
100-C12  
100-C12  
100-C16  
100-C16  
100-C23  
100-C23  
100-C30  
100-C37  
100-C43  
3
31  
3
31  
3
20  
20  
20  
32  
32  
32  
32  
1.5  
3
2.2  
4
2.2  
4
4
6.5  
12  
5.3  
9
4
7
5
3
5.5 ➊  
4
4
12  
12 ➊  
9
7
31  
10  
01  
10  
01  
10  
01  
10  
01  
00  
00  
00  
00  
00  
00  
3
4
12  
7
4
5.5  
7.5  
11  
5.5  
7.5  
13  
5.5  
7.5  
10  
15  
12  
10  
14  
20  
7
5.5  
7.5  
20  
16  
9
26.5  
23  
12  
50  
50  
85  
100  
100  
100  
10  
11  
13  
18.5  
22  
25  
15  
18.5 / 20  
22  
15  
20  
25  
37  
45  
55  
15  
18.5  
22  
32  
40  
35  
38  
44  
62  
72  
85  
30  
37  
43  
60  
72  
85  
25  
30  
38  
55  
67  
80  
18  
21  
25  
34  
42  
49  
32  
40  
45  
100-C60  
100-C72  
100-C85  
1
45  
CAB6-85-00-  
CAB6-85-11-  
CAB6-105-00-  
CAB6-105-11-  
CAB6-105-EI-00-  
CAB6-105-EI-11-  
CAB6-140-00-  
CAB6-140-11-  
CAB6-140-EI-00-  
CAB6-140-EI-11-  
CAB6-170-EI-00-  
CAB6-170-EI-11-  
CAB6-210-EI-00-  
CAB6-210-EI-11-  
CAB6-250-EI-00-  
CAB6-250-EI-11-  
CAB6-300-EI-00-  
CAB6-300-EI-11-  
CAB6-420-EI-00-  
CAB6-420-EI-11-  
160  
25  
32  
45  
55  
55  
80  
85  
85  
85  
85  
160  
63  
100  
105  
105  
105  
105  
80  
90  
110  
132  
160  
200  
250  
300  
140  
140  
170  
210  
250  
300  
420  
140  
140  
170  
210  
250  
300  
420  
115  
140  
170  
210  
250  
300  
115  
140  
170  
210  
250  
300  
250  
45  
75  
1
250  
350  
350  
450  
500  
55  
63  
90 / 100  
110  
110  
150  
160  
200  
80  
132 / 150  
160  
90  
132  
220 / 250  
300 425 ➊  
420 420 ➊  
Bulletin CAB contactors are suitable for use with operating voltages up to 1000V. Bulletin CAB6-...-El contactors are equipped with electronic coil control  
Power ratings: Preferred values according to IEC 60072-1  
Value applies only to AC-2 and AC-3  
Value applies only to AC-2 and AC-3; AC-4: 360 A  
PQ = Package Quantity  
Accessories - Page 4-24  
Specifications - Page 4-36  
Dimensions - Page 4-61  
4-10  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Product Selection  
Selection of Options  
Options  
Cat. No. Suffix Description  
Ordering Example  
No Entry  
Line-side coil connection (above, standard quantity)  
Load-side coil connection (below)  
Voltage suffix code from table below  
Multi-pack (10 pieces) (Only KD, D, KF, KK)  
100-C09 10  
100-C09U 10  
100-C09KJ10  
100-M09N 3  
100-M09N 3S  
100-C09 10  
100-C09 10M  
Coil connection position  
Voltage suffix code  
U
e.g. KJ  
No Entry  
S
Package quantity 100-M  
Single item (1 piece, standard quantity)  
Single item (1 piece, standard quantity)  
Multi-pack (20 pieces)  
No Entry  
M
Package quantity 100-C  
4
Attention:  
Bulletin 100-M…S: standard quantity = single item (1 piece)  
Bulletin 100-C, CAB6: standard quantity = single item (1 piece)  
!
Voltage Suffix Codes for AC Control  
110-  
120  
220- 230-  
230 240  
380- 400-  
400 415  
[V] 24  
48 110  
230  
240  
100-M  
50 Hz  
60 Hz  
D
D
(A)  
(A)  
KK  
KK  
50/60 Hz KD KH  
KF  
(KT)  
100-  
110  
200- 200- 208-  
220 230 240  
[V] 12 24  
32  
36  
42  
48  
100  
110 120 127 200  
50 Hz  
(R) (K) (V) (W) (X)  
(Y) (KP)  
(X)  
KY (KP)  
(KP)  
(D)  
(P)  
(D)  
(S) (KG)  
(KG)  
(L)  
60 Hz  
(Q) (J)  
(V)  
50/60 Hz  
KJ  
KD  
(KG)  
(KL)  
100-C  
220-  
230  
230-  
240  
380-  
400  
400-  
415  
[V]  
230  
240 277 347 380  
400  
440 480 500 550 600  
50 Hz  
(F)  
(VA) (T)  
(T)  
(I)  
(E)  
(N)  
(G)  
(B)  
(N)  
(B)  
(M)  
(C)  
(C)  
60 Hz  
(A)  
50/60 Hz  
KF  
(KA)  
KN  
(KB)  
220-  
230  
380-  
400  
440-  
460  
[V] 24  
28  
48  
55  
110 127  
230 240 260 277  
415  
480  
CAB6-85…CAB6-140 ➊  
50 Hz  
60 Hz  
05  
05  
08  
08  
10  
10  
13  
(15)  
16  
(17)  
13 (15)  
16 (17)  
50/60 Hz  
(48)  
54 (55)  
24- 43- 110- 208- 380-  
[V]  
28  
05  
65 130 277 400  
50/60 Hz  
50/60 Hz  
08  
08  
10  
10  
14  
14  
16  
16  
CAB6-105-EI…CAB6-250-E ➊  
CAB6-300-EI…CAB6-420-EI ➊  
Price Adder for:  
Type  
Available Control Voltages  
No Surcharge  
100-M  
100-C  
12…500 V 50 Hz, 12…600 V 60 Hz  
12…600 V 50 Hz, 12…600 V 60 Hz  
> 25 pieces  
> 20 pieces  
> 25 pieces  
Special control voltages  
CAB6-85…CAB6-140 ➊  
21…550 V 50 Hz, 21…575 V 60 Hz, 110…240 V 50/60 Hz  
( ) Control voltages in parentheses: No inventory  
50/60 Hz coil only available for CAB6-85 and 105  
Signal voltage of the CAB6...EI electronic interface:  
U : 24 VDC / I : 15 mA  
Logical 1: 13.0 VDC…30.2 VDC  
e
e
Logical 0: -3.0 VDC…+5.0 VDC  
Accessories - Site 4-24  
Specifications - Page 4-36  
Dimensions - Page 4-61  
Rockwell Automation  
4-11  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Product Selection  
3-pole Contactors  
DC control  
3 main contacts  
4
100-M..Z  
AC-1  
100-C..Z  
100-C..Z  
CAB6  
Auxiliary  
Contacts  
Internal  
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)  
(40 °C)  
[kW] ➊  
[A]  
Cat. No.  
PQ  
[A]  
230 V 400 / 415 V 500 V 690 V 230 V 400 / 415 V 500 V 690 V  
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
0
2
2
0
1
2
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
0
0
2
2
0
1
2
0
1
0
1
0
1
0
1
0
1
0
1
100-M05N  
3
20  
20  
20  
32  
32  
32  
32  
1.5  
3
2.2  
4
2.2  
4
4
6.5  
12  
5.3  
9
4
7
5
100-M05N  
100-M09N  
31  
3
100-M09N  
31  
3
100-M12N  
3
5.5 ➊  
4
4
12  
12 ➊  
9
7
100-M12N  
31  
10  
01  
10  
01  
10  
01  
10  
01  
00  
00  
00  
00  
00  
00  
100-C09  
3
4
12  
7
100-C09  
100-C12  
4
5.5  
7.5  
11  
5.5  
7.5  
13  
5.5  
7.5  
10  
15  
12  
10  
14  
20  
7
100-C12  
100-C16  
5.5  
7.5  
20  
16  
9
100-C16  
100-C23  
26.5  
23  
12  
100-C23  
50  
50  
10  
11  
15  
18.5 / 20  
22  
15  
20  
25  
37  
45  
55  
55  
15  
18.5  
22  
35  
38  
44  
62  
72  
85  
85  
30  
37  
43  
60  
72  
85  
85  
25  
30  
38  
55  
67  
80  
85  
18  
21  
25  
34  
42  
49  
85  
100-C30  
100-C37  
85  
13  
100-C43  
100  
100  
100  
160  
18.5  
22  
32  
32  
100-C60  
1
40  
40  
100-C72  
25  
45  
45  
100-C85  
25  
45  
80  
CAB6-85-L22-  
CAB6-105-L22-  
CAB6-105-EI-00-  
CAB6-105-EI-11-  
CAB6-140-L22-  
CAB6-140-EI-00-  
CAB6-140-EI-11-  
CAB6-170-EI-00-  
CAB6-170-EI-11-  
CAB6-210-EI-00-  
CAB6-210-EI-11-  
CAB6-250-EI-00-  
CAB6-250-EI-11-  
CAB6-300-EI-00-  
CAB6-300-EI-11-  
CAB6-420-EI-00-  
CAB6-420-EI-11-  
160  
250  
32  
45  
55  
75  
63  
100  
105  
105  
105  
105  
80  
90  
110  
132  
140  
140  
140  
140  
115  
140  
115  
140  
250  
350  
350  
450  
500  
55  
63  
90 / 100  
110  
110  
150  
160  
200  
160  
200  
250  
300  
170  
210  
250  
300  
420  
170  
210  
250  
300  
420  
170  
210  
250  
300  
170  
210  
250  
300  
1
80  
132 / 150  
160  
90  
132  
220 / 250  
300 425 ➊  
420 420 ➊  
Bulletin CAB contactors are suitable for use with operating voltages up to 1000V. Bulletin CAB6-...-El contactors are equipped with electronic coil control  
Power ratings: Preferred values according to IEC 60072-1  
Value applies only to AC-2 and AC-3  
Value applies only to AC-2 and AC-3; AC-4: 360 A  
PQ = Package Quantity  
Accessories - Site 4-24  
Specifications - Page 4-36  
Dimensions - Page 4-61  
4-12  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Product Selection  
Selection of Options  
Options  
Cat. No. Suffix Description  
Ordering Example  
No Entry  
Line-side coil connection (above, standard quantity)  
Load-side coil connection (below)  
100-C09 10  
100-C09U 10  
100-C09ZJ10  
100-M09N 3  
100-M09N 3S  
100-C09 10  
100-C09 10M  
Coil connection position  
Voltage suffix code  
U
e.g. ZJ  
No Entry  
S
Voltage suffix code from table below  
Multi-pack (10 pieces) (Only Z24, ZD24)  
Single item (1 piece, standard quantity)  
Single item (1 piece, standard quantity)  
Multi-pack (20 pieces)  
Package quantity 100-M  
No Entry  
M
Package quantity 100-C  
4
Attention:  
Bulletin 100-M…S: standard quantity = single item (1 piece)  
Bulletin 100-C, CAB6: standard quantity = single item (1 piece)  
!
Voltage Suffix Codes for DC Control  
[V] 24  
48  
110  
220  
100-M  
DC Z24 (Z48) Z11 (Z2)  
with diode protection circuit DC ZD24  
[V] 9 ➊  
12  
24 36  
48  
60  
64  
72  
80 110 115 125 220 230 250  
100-C09…C43  
DC (ZR) (ZQ)  
ZJ (ZW) (ZY) (ZZ) (ZB) (ZG) (ZE) ZD (ZP) (ZS) (ZA) (ZF) (ZT)  
with diode protection circuit DC  
100-C60…C85 DC  
DJ  
with diode protection circuit DC (DR) (DQ)  
DJ (DW) (DY) (DZ) (DB) (DG) (DE) DD (DP) (DS) (DA) (DF) (DT)  
[V] 24  
48  
110  
76  
220  
CAB6-85…CAB6-140 ➊  
DC  
66  
(70)  
(86)  
24-  
28  
48-  
72  
90- 110- 170- 190-  
[V]  
135  
135 255 255  
CAB6-105-EI…CAB6-300-EI  
CAB6-420-EI  
DC  
DC  
66  
(70)  
(70)  
76  
(86)  
76  
(86)  
Price Adder for:  
Type  
Available Control Voltages  
No Surcharge  
100-M..Z  
100-C..Z  
12…250 VDC  
12…250 VDC  
24…240 VDC  
> 25 pieces  
> 20 pieces  
> 25 pieces  
Special control voltages  
CAB6-85…CAB6-140  
( ) Control voltages in parentheses: No inventory  
Extended operating limits 0.65…1.3 x U  
Extended operating limits 0.7…1.25 x U  
s
s
With conventional DC control, the pickup winding must be interconnected with the late-breaking auxiliary contacts  
Accessories - Page 4-24  
Specifications - Page 4-36  
Dimensions - Page 4-61  
Rockwell Automation  
4-13  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Product Selection  
Special Versions  
AC / DC control  
4-pole contactors  
Latched contactors  
4
100-M  
100-C  
100-ML  
4-pole Contactors Bulletin 100-M, 100-C  
Main Poles  
(Fitted)  
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)  
AC-1  
(40°C)  
Available  
Options  
Cat. No.  
PQ  
[kW] ➊  
[A]  
[A]  
230 V 400 / 415 V 500 V 690 V 230 V 400 / 415 V 500 V 690 V  
20  
3
4
4
12  
9
7
4
4
3
2
0
0
1
2
AC/DC  
AC/DC  
100-M09N  
100-C23  
100-C23  
100-C23  
4
400  
300  
200  
32  
7.5  
11  
13  
10  
26.5  
23  
20  
12  
AC/DC ➊  
(4-pole 100-C09…C16 contactors available upon request)  
Latched Contactors Bulletin 100-ML  
Auxiliary  
Contacts  
Latched  
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)  
AC-1  
(40°C)  
Cat. No.  
PQ  
Available  
Options  
Contactors  
[kW]  
[A]  
[A]  
230 V 400 / 415 V 500 V 690 V 230 V 400 / 415 V 500 V 690 V  
1
0
0
1
AC  
AC  
100-ML09N 3  
100-ML09N 31  
20  
3
4
4
12  
9
7
1
Options  
Cat. No. Suffix Description  
Ordering Example  
No Entry  
U
e.g. KJ  
No Entry  
S
Line-side coil connection (above, standard quantity)  
Load-side coil connection (below)  
Voltage suffix code from table below  
100-C23 400  
100-C23U 400  
100-C23KJ400  
100-M09N 4  
100-M09N 4S  
100-C23 400  
100-C23 400M  
Coil connection position  
Tension de commande  
Multi-pack (10 pieces) (Only KD, D, KF, KK, Z24, ZD24)  
Single item (1 piece, standard quantity)  
Single item (1 piece, standard quantity)  
Multi-pack (20 pieces)  
Package quantity 100-M  
No Entry  
M
Package quantity 100-C  
AC-4 value only for contact assembly with 3 resp, 4 N.O. contacts  
Power ratings: Preferred values according to IEC 60072-1  
No inventory  
Attention:  
Bulletin 100-M…S: standard quantity = single item (1 piece)  
Bulletin 100-C: standard quantity = single item (1 piece)  
!
PQ = Package Quantity  
Accessories - Site 4-24  
Specifications - Page 4-36  
Dimensions - Page 4-61  
4-14  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Product Selection  
Voltage Suffix Codes for AC Control  
110-  
120  
220- 230-  
230 240  
380- 400-  
400 415  
[V] 24  
48  
110  
230  
240  
100-M  
50 Hz  
60 Hz  
D
D
(A)  
(A)  
KK  
KK  
50/60 Hz KD  
KH  
KF  
(KT)  
100-  
110  
200- 200- 208-  
220 230 240  
[V] 12  
24  
32  
36  
42  
48  
100  
110 120 127 200  
50 Hz  
(R)  
(Q)  
(K)  
(J)  
KJ  
(V)  
(W)  
(V)  
(X)  
(Y) (KP)  
(X)  
KY (KP)  
(KP)  
(D)  
(P)  
(D)  
(S) (KG)  
(KG)  
(L)  
60 Hz  
4
50/60 Hz  
KD  
(KG)  
(KL)  
100-C  
220-  
230  
230-  
240  
380-  
400  
400-  
415  
[V]  
230  
240 277 347 380  
400  
440 480 500 550 600  
50 Hz  
(F)  
(VA) (T)  
(T)  
(I)  
(E)  
(N)  
(G)  
(B)  
(N)  
(B)  
(M)  
(C)  
(C)  
60 Hz  
(A)  
50/60 Hz  
KF  
(KA)  
KN  
(KB)  
Voltage Suffix Codes for DC Control  
[V] 24  
48  
110 220  
100-M  
DC  
Z24 (Z48) Z11 (Z2)  
ZD24  
[V] 9 ➊  
with diode protection circuit DC  
12 24 36  
48  
60  
64  
72  
80  
110 115 125 220 230 250  
100-C09…C43  
DC  
(ZR) (ZQ) ZJ (ZW) (ZY) (ZZ) (ZB) (ZG) (ZE) ZD (ZP) (ZS) (ZA) (ZF) (ZT)  
with diode protection circuit DC  
DJ  
100-C60…C85  
DC  
with diode protection circuit DC  
(DR) (DQ) DJ (DW) (DY) (DZ) (DB) (DG) (DE) DD (DP) (DS) (DA) (DF) (DT)  
Price Adder for:  
Type  
Available Control Voltages  
No Surcharge  
100-M  
100-C  
12…500 V 50 Hz, 12…600 V 60 Hz, 12…250 VDC  
12…600 V 50 Hz, 12…600 V 60 Hz, 12…250 VDC  
> 25 pieces  
> 20 pieces  
Special control voltages  
( ) Control voltages in parentheses: No inventory  
Extended operating limits 0.65…1.3 x U  
Extended operating limits 0.7…1.25 x U  
s
s
Accessories - Page 4-24  
Specifications - Page 4-36  
Dimensions - Page 4-61  
Rockwell Automation  
4-15  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Product Selection  
Reversing Contactors  
3 main contacts, coil connections above  
Mechanical / Electrical interlock included  
Wiring set for main pole interconnection included  
4
Auxiliary  
Contact  
Auxiliary  
Contact  
AC-1  
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)  
(40°C)  
per Contactor  
on Interlock  
Cat. No.  
PQ  
[kW] ➊  
[A]  
[A] 230 V 400 / 415 V 500 V 690 V 230 V 400 / 415 V 500 V 690 V  
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
1
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
1
1
1
0
0
0
0
0
0
0
0
2
0
2
0
2
0
2
2
2
0
0
0
➊➊ 104-M05N  
3
31  
3
31  
3
20  
20  
20  
32  
32  
32  
32  
1.5  
3
2.2  
4
2.2  
4
4
6.5  
12  
5.3  
9
4
7
5
104-M05N  
➊➊ 104-M09N  
1
104-M09N  
➊➊ 104-M12N  
3
5.5 ➊  
4
4
12  
12 ➊  
9
7
104-M12N  
104-C09  
104-C09  
104-C12  
104-C12  
104-C16  
104-C16  
104-C23  
104-C23  
104-C30  
104-C37  
104-C43  
104-C60  
104-C72  
104-C85  
31  
10 -E ➊  
00 -E ➊  
10 -E ➊  
00 -E ➊  
10 -E ➊  
00 -E ➊  
10 -E ➊  
00 -E ➊  
00 -E ➊  
00 -E ➊  
00 -E ➊  
10 -E ➊  
10 -E ➊  
10 -E ➊  
3
4
12  
7
4
5.5  
7.5  
11  
5.5  
7.5  
13  
5.5  
7.5  
10  
15  
12  
10  
14  
20  
7
5.5  
20  
16  
9
7.5  
26.5  
23  
12  
1
50  
50  
85  
100  
100  
100  
10  
11  
13  
18.5  
22  
25  
15  
18.5 / 20  
22  
15  
20  
25  
37  
45  
55  
15  
18.5  
22  
32  
40  
35  
38  
44  
62  
72  
85  
30  
37  
43  
60  
72  
85  
25  
30  
38  
55  
67  
80  
18  
21  
25  
34  
42  
49  
32  
40  
45  
45  
Bulletin CAB contactors are suitable for use with operating voltages up to 1000V. Bulletin CAB6-...-El contactors are equipped with electronic coil control  
160  
160  
25  
32  
45  
55  
55  
63  
80  
85  
85  
85  
85  
1
1
1
1
0
0
CAU B6-85-  
CAU B6-105-  
10  
10  
100  
105  
105  
105  
105  
CAU B6-105-EI- 10  
80  
90  
110  
150  
160  
200  
110  
132  
160  
200  
250  
300  
140  
140  
170  
210  
250  
300  
140  
140  
170  
210  
250  
300  
420  
115  
140  
170  
210  
250  
300  
115  
140  
170  
210  
250  
300  
1
1
1
1
1
1
1
1
1
1
1
1
1
1
0
0
0
0
0
0
0
CAU B6-140- 10  
250  
45  
75  
CAU B6-140-EI- 10  
CAU B6-170-EI- 10  
CAU B6-210-EI- 10  
CAU B6-250-EI- 10  
CAU B6-300-EI- 10  
CAU B6-420-EI- 10  
1
250  
350  
350  
450  
500  
55  
63  
80  
90  
132  
90 / 100  
110 / 125  
132 / 150  
160  
220 / 250 300 425 420  
420 420➊  
Options  
Cat. No. Suffix  
Description  
Ordering Example  
No Entry  
with mechanical interlock (standard)  
without mechanical interlock  
104-M05N 3  
Mechanical interlock  
-X  
No Entry  
M
104-M05N 3-X  
CAU-B6-105-EI-10  
CAUMB6-105-EI-10  
104-M05NKJ3  
without mechanical interlock (standard)  
with mechanical interlock  
Voltage suffix code from the table on the next page  
Mechanical interlock  
Voltage suffix code  
e.g. KJ  
Value applies only to AC-2 and AC-3  
Power ratings: Preferred values according to IEC 60072-1  
DC-control only available without mechanical interlock  
For electronic interlock additional N.C. contacts required  
Bulletin100-MCA00mechanicalinterlock.Electricalinterlockviathe  
front mounted auxiliary contact block (2 pole)  
Value applies only to AC-2 and AC-3; AC-4: 360 A  
PQ = Package Quantity  
Accessories - Page 4-24  
Specifications - Page 4-36  
Dimensions - Page 4-61  
4-16  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Product Selection  
Voltage Suffix Codes for AC Control  
110-  
120  
D
220- 230-  
230 240  
380- 400-  
400 415  
KK  
[V] 24 48 110  
230  
240  
104-M  
50 Hz  
60 Hz  
D
KF  
(A)  
(A)  
(KT)  
100-  
110  
KK  
50/60 Hz KD KH  
200- 200-  
220 230  
208-  
240  
[V] 12 24 32  
36  
42  
48 100  
110 120 127 200  
208  
50 Hz  
(R) (K) (V) (W) (X) (Y) (KP)  
(D) (P) (S) (KG)  
(KG)  
(KL)  
60 Hz  
50/60 Hz  
(Q) (J)  
230-  
240  
(VA) (T)  
(V)  
(X)  
KY (KP)  
(KP)  
380-  
400  
(N)  
KD  
(D)  
400-  
415  
(G) (B)  
(KG)  
(H) (L)  
220-  
230  
(F)  
KJ  
104-C  
4
[V]  
230  
240 277 347 380  
400  
440 480 500 550 600  
50 Hz  
60 Hz  
50/60 Hz  
(I)  
(E)  
KN  
(M) (C)  
(C)  
(A) (T)  
(KA)  
(N) (B)  
(KB)  
KF  
220-  
230  
13  
380-  
400  
16 (17)  
440-  
460  
16 (17)  
[V] 24 28 48  
55 110 127  
230 240 260 277  
415  
480  
CAUB6-85…CAUB6-140 ➊  
50 Hz  
60 Hz  
05  
05  
08  
08  
10  
(48)  
10  
(15)  
13 (15)  
50/60 Hz  
54 (55)  
24- 43- 110- 208- 380-  
28 65 130 277 400  
[V]  
CAUB6-105-EI…CAUB6-250-EI  
CAUB6-300-EI…CAUB6-420-EI  
50/60 Hz 05 08 10  
50/60 Hz 08 10  
14  
14  
16  
16  
Voltage Suffix Codes for DC Control  
[V] 24  
48  
110 220  
104-M  
DC  
Z24 (Z48) Z11 (Z2)  
with diode protection circuit DC  
ZD24  
[V] 9 ➊  
DC  
with diode protection circuit DC  
12  
24 36  
48  
60  
64  
72  
80 110 115 125 220 230 250  
104-C09…C43  
(ZR) (ZQ)  
ZJ (ZW) (ZY) (ZZ) (ZB) (ZG) (ZE) ZD (ZP) (ZS) (ZA) (ZF) (ZT)  
DJ  
104-C60…C85  
DC  
with diode protection circuit DC  
(DR) (DQ) DJ (DW) (DY) (DZ) (DB) (DG) (DE) DD (DP) (DS) (DA) (DF) (DT)  
[V] 24  
48  
(70)  
48-  
72  
(70)  
(70)  
110 220  
76 (86)  
90- 110- 170- 190-  
135 135 255 255  
CAB6-85…CAB6-140  
DC  
66  
24-  
28  
66  
[V]  
CAB6-105-EI…CAB6-300-EI  
CAB6-420-EI  
DC  
DC  
76  
(86)  
(86)  
76  
Price Adder for:  
Type  
Available Control Voltages  
No Surcharge  
> 25 pieces  
> 20 pieces  
104-M  
104-C  
12…500 V 50 Hz, 12…600 V 60 Hz, 12…250 VDC  
12…600 V 50 Hz, 12…600 V 60 Hz, 12…250 VDC  
21…550 V 50 Hz, 21…575 V 60 Hz, 110…240 V 50/60 Hz,  
24…240 VDC  
Special control voltages  
CAUB6-85…CAUB6-140 ➊  
> 25 pieces  
( ) Control voltages in parentheses: No inventory  
Wiring per IEC standard  
50/60 Hz coils for CAB6-140 contactor not available  
E
Extended operating limits 0.65…1.3 x U  
Extended operating limits 0.7…1.25 x U  
s
s
Accessories - Page 4-24  
Specifications - Page 4-36  
Dimensions - Page 4-61  
Rockwell Automation  
4-17  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Product Selection  
Safety Contactors  
AC / DC control  
3 / 4 main contacts  
Positively guided contacts according to IEC 947-5-1  
Mechanically coupled Contactor and Auxiliary contact block  
Protection against unintended actuation  
Auxiliary contacts are electronically compatible according to  
DIN 19240  
4
With 3 Main Contacts  
Positively Guided  
Auxiliary Contacts  
AC-1  
(40°C)  
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)  
Cat. No.  
PQ  
[kW] ➊  
[A]  
[A]  
230 V 400 / 415 V 500 V  
690 V  
230 V 400 / 415 V 500 V 690 V  
0
1
2
0
1
2
0
1
2
0
1
2
0
2
0
2
0
2
0
2
0
2
0
2
5
4
3
5
4
3
5
4
3
5
4
3
4
2
4
2
4
2
4
2
4
2
4
2
100S-C09 05C  
100S-C09 14C  
100S-C09 23C  
100S-C12 05C  
100S-C12 14C  
100S-C12 23C  
100S-C16 05C  
100S-C16 14C  
100S-C16 23C  
100S-C23 05C  
100S-C23 14C  
100S-C23 23C  
100S-C30 04C  
100S-C30 22C  
100S-C37 04C  
100S-C37 22C  
100S-C43 04C  
100S-C43 22C  
100S-C60 04C  
100S-C60 22C  
100S-C72 04C  
100S-C72 22C  
100S-C85 04C  
100S-C85 22C  
32  
3
4
4
4
11.5  
14.5  
20  
9
7
5
7
32  
32  
32  
4
5.5  
7.5  
11  
5.5  
7.5  
11  
5.5  
7.5  
10  
12  
10  
13  
18  
5.5  
7.5  
16 / 15  
23 / 22  
9.3  
12  
24  
1
50  
50  
10  
11  
15  
18.5  
22  
15  
18.5  
22  
15  
18.5  
22  
34  
37  
42  
62  
70  
85  
30 / 29  
37 / 36  
43 / 41  
60 / 58  
72 / 69  
85 / 82  
24  
30  
34  
45  
56  
67  
17  
20  
25  
34  
42  
49  
85  
13  
100  
100  
100  
18.5  
22  
30  
30  
30  
37  
37  
37  
25  
45  
45  
45  
With 4 Main Contacts  
Positively Guided  
Auxiliary Contacts  
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)  
AC-1  
(40°C)  
Cat. No.  
PQ  
[kW] ➊  
[A]  
230 V 400 / 415 V 500 V 690 V  
[A]  
230 V 400 / 415 V 500 V  
690 V  
0
0
2
2
4
4
2
2
100S-C23 404C  
100S-C23 304C  
100S-C23 422C  
100S-C23 322C  
32  
7.5  
11  
11  
10  
24  
23 / 22  
18  
12  
1
PQ = Package Quantity  
Accessories - Page 4-24  
Specifications - Page 4-36  
Dimensions - Page 4-61  
4-18  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Product Selection  
Reversing-Safety Contactors  
AC / DC control  
3 main contacts, coil connections above  
Positively guided contacts acc. to IEC 947-5-1  
Mechanically coupled Contactor and Auxiliary contact block  
Protection against unintended actuation  
Auxiliary contacts are electronically compatible according  
to DIN 19240  
4
Mechanical / Electrical interlock included  
Wiring set for main pole interconnection included  
With 3 Main Contacts  
Positively Guided  
Aux. contact per Contactor  
AC-1  
(40°C)  
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)  
Cat. No.  
PQ  
[kW] ➊  
[A]  
[A]  
230 V 400 / 415 V 500 V 690 V 230 V 400 / 415 V 500 V 690 V  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
5
5
5
5
5
5
5
5
4
4
4
4
4
4
4
4
4
4
4
4
104S-C09 012C  
104S-C09 010C  
104S-C12 012C  
104S-C12 010C  
104S-C16 012C  
104S-C16 010C  
104S-C23 012C  
104S-C23 010C  
104S-C30 010C  
104S-C30 008C  
104S-C37 010C  
104S-C37 008C  
104S-C43 010C  
104S-C43 008C  
104S-C60 010C  
104S-C60 008C  
104S-C72 010C  
104S-C72 008C  
104S-C85 010C  
104S-C85 008C  
32  
3
4
4
5.5  
7.5  
11  
4
5.5  
7.5  
11  
4
5.5  
7.5  
10  
11.5  
14.5  
20  
9
7
5
32  
32  
12  
10  
13  
18  
24  
30  
34  
45  
56  
67  
7
5.5  
7.5  
10  
11  
13  
18.5  
22  
25  
16 / 15  
23 / 22  
30 / 29  
37 / 36  
43 / 41  
60 / 58  
72 / 69  
85 / 82  
9.3  
12  
17  
20  
25  
34  
42  
49  
32  
24  
50  
15  
15  
15  
34  
1
50  
18.5  
22  
18.5  
22  
18.5  
22  
37  
85  
42  
100  
100  
100  
30  
30  
30  
62  
37  
37  
37  
70  
45  
45  
45  
85  
Voltage Suffix Codes for AC Control  
100-  
110  
(KP)  
380-  
400  
(N)  
200- 200- 208-  
220 230 240  
[V] 12  
24  
32  
36  
42  
48  
(Y) (KP)  
(X)  
KY (KP)  
100  
110 120 127 200  
50 Hz  
60 Hz  
(R)  
(Q)  
(K)  
(J)  
KJ  
(V) (W) (X)  
230-  
240  
(VA) (T)  
(D)  
KD  
(P)  
(D)  
(S) (KG)  
(KG)  
(KL)  
(L)  
(V)  
(KG)  
50/60 Hz  
220-  
230  
(F)  
100S-C. 104S-C  
400-  
415  
(G)  
[V]  
230  
240 277 347 380  
400  
440 480 500 550 600  
50 Hz  
60 Hz  
KF  
(T)  
(I)  
(E)  
KN  
(B)  
(N)  
(KB)  
(B)  
(M) (C)  
(C)  
(A)  
(KA)  
50/60 Hz  
Voltage Suffix Codes for DC Control  
[V] 9 12 24 36  
48  
60  
64  
72  
80  
110 115 125 220 230 250  
100S-C09…C43, 104S-C09…C43  
DC  
(ZR) (ZQ) ZJ (ZW) (ZY) (ZZ) (ZB) (ZG) (ZE) ZD (ZP) (ZS) (ZA) (ZF) (ZT)  
with diode protection circuit DC  
100S-C60…C85, 104S-C60…C85 DC  
with diode protection circuit DC  
DJ  
(DR) (DQ) DJ (DW) (DY) (DZ) (DB) (DG) (DE) DD (DP) (DS) (DA) (DF) (DT)  
Price Adder for:  
Special control voltages  
Type  
100S-C. 104S-C  
Available Control Voltages  
12…600 V 50 Hz, 12…600 V 60 Hz, 12…250 VDC  
No Surcharge  
> 20 pieces  
( ) Control voltages in parentheses: No inventory  
Extended operating limits 0.65…1.3 x U  
Power ratings: Preferred values according to IEC 60072-1  
With mechanical and electrical locking 100-MCA02  
s
Extended operating limits 0.7…1.25 x U  
s
Accessories - Page 4-24  
Specifications - Page 4-36  
Dimensions - Page 4-61  
Rockwell Automation  
4-19  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Assignment of Contacts  
Contactors with 3 Main Contacts  
51 61 71 81  
51 61 71 81  
53 61 71 83  
62 72  
62 72  
62 72  
52  
1
82  
21  
52  
1
82  
13  
54  
1
84  
21  
3
5
3
5
3
5
4
6
4
6
4
6
2
22  
2
14  
2
22  
100S-C09 05C…C23 05C  
100S-C09 14C…C23 14C  
100S-C09 23C…C23 23C  
4
11 21 31 41  
13 21 31 43  
22 32  
3
22 32  
3
12  
1
42  
5
14  
1
44  
5
4
6
4
6
2
2
100S-C30 04C…C85 04C  
100S-C30 22C…C85 22C  
Contactors with 4 Main Contacts  
11 21 31 41  
11 21 31 41  
22 32  
22 32  
42  
12  
1
42  
7
12  
1
3
5
3
5
R1  
4
6
4
6
2
8
2
R2  
100S-C23 404C  
100S-C23 304C  
13 21 31 43  
13 21 31 43  
22 32  
22 32  
44  
14  
1
44  
7
14  
1
3
5
3
5
R1  
4
6
4
6
2
8
2
R2  
100S-C23 422C  
100S-C23 322C  
Product Selection - Page 4-10  
4-20  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Assignment of Contacts  
Reversing-Safety Contactors with 3 Main Contacts  
51 61 71 81  
51 61 71 81  
51 61 71 81  
21  
51 61 71 81  
62 72  
62 72  
52  
1
82  
21  
52  
1
82  
21  
62 72  
62 72  
52  
1
82  
21  
22  
21  
52  
1
82  
21  
3
5
3
5
6
3
4
5
6
3
4
5
6
4
6
4
2
22  
2
22  
2
22  
22  
2
22  
4
104S-C09 012C…C23 012C  
104S-C09 010C…C23 010C  
51 61 71 81  
21  
51 61 71 81  
51 61 71 81  
51 61 71 81  
62 72  
3
62 72  
3
52  
1
82  
5
22  
21  
52  
1
82  
5
62 72  
3
62 72  
3
52  
1
82  
5
52  
1
82  
5
4
4
2
6
22  
2
6
4
4
2
6
2
6
104S-C30 010C…C85 010C  
104S-C30 008C…C85 008C  
Product Selection - Page 4-10  
Rockwell Automation  
4-21  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Assignment of Contacts  
Device Combinations in Accordance with EN Standards  
Auxiliary Contact Blocks  
Contactors 100-C (AC / DC Control)  
100-C30  
100-C37  
100-C43  
100-C60  
100-C72  
100-C85  
00  
00  
00  
00  
00  
00  
5
100-C09  
100-C12  
100-C16  
100-C23  
10  
10  
10  
10  
100-C09  
100-C12  
100-C16  
100-C23  
01  
01  
01  
01  
Circuit Diagram Control  
100-C23  
400 100-C23  
300 100-C23  
200  
1
3
4
5
6
1
3
4
1
2
1
2
13  
1
3
4
5
A1  
1
3
4
5
6
3
4
5
6
R1  
R2  
R1  
R3  
3
4
A1  
21  
22  
7
8
A1  
A2  
A1  
A2  
A1  
A1  
K1  
K1  
K1  
K1  
K1  
K1  
A2  
2
A2  
2
14  
A2  
2
6
A2  
2
6
R2 R4  
Front-mounted ➊  
4
51 61  
100-FA02  
AC / DC  
AC / DC  
AC / DC  
AC / DC  
10 + 02 = 12  
10 + 11 = 21  
01 + 02 = 03  
01 + 11 = 12  
00 + 02 = 02  
00 + 11 = 11  
00 + 11 = 11  
00 + 02 = 02  
00 + 11 = 11  
00 + 11 = 11  
00 + 02 = 02  
00 + 11 = 11  
00 + 11 = 11  
00 + 02 = 02  
00 + 11 = 11  
00 + 11 = 11  
52 62  
53 61  
100-FA11  
100-FB11  
100-FC11  
54 62  
13 21  
14 22  
23 31  
10 + 11 = 21  
01 + 11 = 12  
24 32  
53 63  
100-FA20  
AC / DC  
10 + 20 = 30  
01 + 20 = 21  
00 + 20 = 20  
00 + 11 = 11  
00 + 20 = 20  
00 + 11 = 11  
00 + 20 = 20  
00 + 11 = 11  
00 + 20 = 20  
00 + 11 = 11  
54 64  
17 25  
100-FBL11  
AC / DC  
18 26  
53 61 71 83  
100-FA22  
100-FB22  
AC / DC  
AC / DC  
10 + 22 = 32  
01 + 22 = 23  
00 + 22 = 22  
00 + 22 = 22  
00 + 22 = 22  
00 + 22 = 22  
00 + 22 = 22  
00 + 22 = 22  
00 + 22 = 22  
00 + 22 = 22  
54 62 72 84  
13 21 31 43  
14 22 32 44  
21 31 43 53  
100-FC22  
100-FA31  
100-FA40  
AC / DC  
AC / DC  
10 + 22 = 32  
10 + 31 = 41  
10 + 40 = 50  
10 + 22 = 32  
22 32 44 54  
53 61 73 83  
01 + 31 = 32  
01 + 40 = 41  
01 + 22 = 23  
00 + 31 = 31  
00 + 40 = 40  
00 + 22 = 22  
00 + 31 = 31  
00 + 40 = 40  
00 + 22 = 22  
00 + 31 = 31  
00 + 40 = 40  
00 + 22 = 22  
00 + 31 = 31  
00 + 40 = 40  
00 + 22 = 22  
54 62 74 84  
53 63 73 83  
AC / DC  
54 64 74 84  
53 61 75 87  
100-FAL22  
AC / DC  
54 62 76 88  
Side-mounted ➊  
21  
3 2  
100-SB01  
100-SB10  
100-SB02  
100-SB11  
100-SB20  
AC / DC  
AC / DC  
AC / DC  
AC / DC  
AC / DC  
10 + 01 = 11  
01 + 01 = 02 ➊  
01 + 10 = 11  
00 + 01 = 01  
00 + 10 = 10  
00 + 02 = 02  
00 + 11 = 11  
00 + 20 = 20  
00 + 01 = 01  
00 + 10 = 10  
00 + 02 = 02  
00 + 11 = 11  
00 + 20 = 20  
00 + 01 = 01  
00 + 10 = 10  
00 + 02 = 02  
00 + 11 = 11  
00 + 20 = 20  
00 + 01 = 01  
00 + 10 = 10  
00 + 02 = 02  
00 + 11 = 11  
00 + 20 = 20  
22  
3 1  
13  
4 4  
10 + 10 = 20 ➊  
10 + 02 = 12 ➊  
10 + 11 = 21 ➊  
10 + 20 = 30 ➊  
10 + 11 = 21 ➊  
14  
4 3  
11 21  
4 2 3 2  
12 22  
4 1 3 1  
13 21  
4 4 3 2  
01 + 11 = 12 ➊  
01 + 20 = 21 ➊  
14 22  
4 3 3 1  
13 23  
4 4 3 4  
14 24  
4 3 3 3  
17 25  
4 8 3 6  
100-SBL11  
AC / DC  
01 + 11 = 12 ➊  
00 + 11 = 11  
00 + 11 = 11  
00 + 11 = 11  
00 + 11 = 11  
18 26  
4 7 3 5  
Product Selection - Page 4-10  
4-22  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Assignment of Contacts  
Device Combinations in Accordance with EN Standards  
Auxiliary Contact Block  
Miniature Contactor 100-M (AC / DC Control)  
100-M05N  
100-M09N  
100-M12N  
3
3
3
100-M05N 31  
100-M09N 31  
100-M12N 31  
Circuit Dia-  
gram  
Control  
100-M09N 4  
1
3
5
6
A1  
13  
1
2
3
4
5
6
A1  
A2  
7
1
3
5
A1  
21  
K1  
K1  
K1  
A2  
2
4
14  
8
A2  
2
4
6
22  
Front-mounted  
21 31  
195-MB02  
AC / DC  
AC / DC  
AC / DC  
10 + 02 = 12  
10 + 11 = 21  
10 + 20 = 30  
40 + 02 = 42  
40 + 11 = 51  
40 + 20 = 60  
22 32  
4
21 33  
195-MB11  
22 34  
53 63  
195-MA20  
01 + 20 = 21  
54 64  
43 53 21 31  
195-MB22  
AC / DC  
AC / DC  
10 + 22 = 32  
10 + 40 = 50  
40 + 22 = 62  
40 + 40 = 80  
44 54 22 32  
53 63 73 83  
195-MA40  
01 + 40 = 41  
54 64 74 84  
Auxiliary Contact Block  
Contactors CAB6 (AC / DC Control)  
CAB6-140-EI-00  
CAB6-170-EI-00  
CAB6-210-EI-00  
CAB6-250-EI-00  
CAB6-300-EI-00  
CAB6-420-EI-00  
CAB6-140-EI-11  
CAB6-170-EI-11  
CAB6-210-EI-11  
CAB6-250-EI-11  
CAB6-300-EI-11  
CAB6-420-EI-11  
CAB6-85-00  
CAB6-105-00  
CAB6-140-00  
CAB6-85-11  
CAB6-105-11  
CAB6-140-11  
CAB6-85-L11  
CAB6-105-L11  
CAB6-140-L11  
CAB6-85-L22  
CAB6-105-L22  
CAB6-140-L22  
Circuit  
Diagram  
Control  
1
2
3
4
5
6
1
2
35  
36  
1
2
35  
36  
A1  
A2  
B1  
3
4
5
6
43  
44  
B1  
3
4
5
6
13 21 43  
A1  
K1  
A1  
K1  
1
2
3
4
5
6
13  
1
3
5
A1  
A2  
21  
A1  
A1  
1
3
5
13 21  
K1  
K1  
K1  
K1  
A2  
2
4
6
A2  
2
4
6
14 22  
A2  
A2  
14  
22  
44  
14 22  
Right-side mounted  
AC  
DC  
00 + 11 = 11  
11 + 11 = 22  
43 31  
CAB6-P2-11  
11+ 11 = 22  
22 + 11 = 33  
44 32  
AC / DC  
AC  
00 + 11 = 11  
11 + 11 = 22  
00 + 11 = 11  
11 + 11 = 22  
83 71  
CAB6-P4-11  
DC  
11 + 11 = 22  
22 + 11 = 33  
84 72  
AC / DC  
AC  
00 + 11 = 11  
11 + 11 = 22  
00+ 11 = 11  
11 + 11 = 22  
35  
43  
CAB6-P2-L11  
CAB6-P2-B11  
DC  
11 + 11 = 22  
22 + 11 = 33  
00 + 11 = 11  
11 + 11 = L22  
44 36  
31  
AC / DC  
AC  
00+ 11 =11  
11 + 11 = 22  
11 + 11 = 22  
22 + 11 = 33  
DC  
32 34  
AC / DC  
00 + 11 = 11  
11 + 11 = 22  
Left-side mounted  
AC  
DC  
00 + 11 = 11  
11 + 11 = 22  
13 21  
CAB6-P1-11  
11 + 11 = 22  
22 + 11 = 33  
14 22  
AC / DC  
AC  
00 + 11 = 11  
11 + 11 = 22  
00 + 11 = 11  
11 + 11 = 22  
53 61  
CAB6-P3-11  
DC  
11 + 11 = 22  
22 + 11 = 33  
00 + 11 = 11  
11 + 11 = 22  
54 62  
AC / DC  
AC  
00 + 11 = 11  
11 + 11 = 22  
11 + 11 = 22  
22 + 11 = 33  
61  
CAB6-P3-B11  
62 64  
DC  
AC / DC  
00+ 11 = 11  
11 + 11 = 22  
Up to 8 auxiliary contacts possible: Contactor + Front-mounted (AC max. 4 N.C:/DC max. 4 N.C.), Side-mounted  
(AC max. 2 N.O./DC max. 2 N.O. and max. 2 N.C.)  
Early make and/or late break  
Double numbering: Because of double numbering only left-side mounting is recommended  
Electronically suited auxiliary contact block  
Product Selection - Page 4-10  
Rockwell Automation  
4-23  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Accessories  
Modules: Auxiliary Contact Blocks  
Description  
Circuit Diagram  
For Use with  
Cat. No.  
PQ  
21 31  
100-M…3  
195-MB02  
22 32  
21 33  
Auxiliary Contact Blocks for Front Mounting  
100-M  
100-M  
195-MB11  
195-MA20  
195-MB22  
22 34  
53 63  
2- and 4-pole  
Simple and quick attachment - no tools needed  
Electronically compatible H-contacts  
Contacts themselves in auxiliary contact block  
positively guided  
10  
4
54 64  
43 53 21 31  
Types with the same functions with several connection  
numbering variants  
100-M…3,  
100-M…4  
44 54 22 32  
53 63 73 83  
100-M  
100-C  
195-MA40  
100-FA02  
100-FA11  
100-FB11  
100-FC11  
54 64 74 84  
51 61  
52 62  
53 61  
100-C  
54 62  
13 21  
C30 00…C85 00  
C09 10…C23 10  
14 22  
23 31  
24 32  
53 63  
100-C  
C30 00…C85 00  
100-C  
100-FA20  
100-FBL11  
100-FA22  
Auxiliary Contact Blocks for Front Mounting ➊  
54 64  
17 25  
2- and 4-pole  
Simple and quick attachment - no tools needed  
Electronically compatible contacts  
Positive guidance in auxiliary and with main contactor  
poles (excluding type L)  
18 26  
53 61 71 83  
Types with the same functions with several connection  
numbering variants  
54 62 72 84  
21 31 43 53  
L = Early Make/Late Break  
C09 10…C23 10  
C30 00…C85 00  
100-C  
100-FC22  
100-FB22  
100-FA31  
100-FA40  
100-FAL22  
22 32 44 54  
13 21 31 43  
14 22 32 44  
53 61 73 83  
54 62 74 84  
53 63 73 83  
100-C  
54 64 74 84  
53 61 75 87  
100-C  
54 62 76 88  
PQ = Package Quantity  
Product Selection - Page 4-10  
4-24  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Accessories  
Modules: Auxiliary Contact Blocks  
Circuit  
Diagram  
Description  
For Use with  
Cat. No.  
PQ  
21  
3 2  
100-C  
100-SB01  
22  
3 1  
13  
4 4  
100-C,  
100S-C ➊  
100-SB10  
14  
4 3  
4
Auxiliary Contact Blocks for Side Mounting ➊  
11 21  
4 2 3 2  
1- and 2-pole  
100-C ➊  
100-C ➊  
100-SB02  
100-SB11  
100-SB20  
100-SBL11  
Dual numbering for left- or right-side mounting on contactor  
Simple and quick attachment - no tools needed  
Electronically compatible contacts  
Positive guidance in auxiliary and with main contactor poles  
(excluding type L)  
12 22  
4 1 3 1  
13 21  
4 4 3 2  
14 22  
4 3 3 1  
L = Early Make/Late Break  
13 23  
4 4 3 4  
100-C,  
100S-C ➊  
14 24  
4 3 3 3  
17 25  
4 8 3 6  
100-C ➊  
18 26  
4 7 3 5  
13 21  
CAB6  
Left-side  
mounting  
CAB6-P1-11  
CAB6-P2-11  
CAB6-P3-11  
CAB6-P4-11  
CAB6-P2-L11  
CAB6-P2-B11  
CAB6-P3-B11  
14  
22  
43 31  
CAB6  
Right-side  
mounting  
Auxiliary Contact Blocks  
44  
32  
Up to 4 auxiliary contact blocks per contactor: P1 and P3  
left, P2 and P4 right  
With mechanical interlock — 2 auxiliary contact blocks per  
contactor, 1 left and 1 right  
No change of base dimensions with 1 auxiliary contact  
block on each side  
53 61  
CAB6  
Left-side  
mounting  
54  
62  
83 71  
CAB6  
Right-side  
mounting  
10  
84  
72  
35  
43  
CAB6  
Right-side  
mounting  
44 36  
31  
CAB6  
Right-side  
mounting  
Electronically compatible auxiliary contacts  
AC-1  
250 V  
0.1 A  
32 34  
61  
CAB6  
Left-side  
mounting  
AC-15, DC-13  
3 … 125 V  
1 … 100 mA  
62 64  
Options  
Cat. No. Suffix  
Description  
Ordering Example  
No Entry  
Single pack (1 piece, standard quantity)  
Multi-pack (10 pieces)  
100-SB10.  
Package quantity  
M
100-SB10M  
Up to 8 auxiliary contacts possible: Contactor + Front-mounted (AC max. 4 N.C:/DC max. 4 N.C.), Side-mounted  
(AC max. 2 N.O./DC max. 2 N.O. and max. 2 N.C.)  
Double numbering: Because of double numbering 100-C09 … 100-C23 only left-side mounting is recommended  
PQ = Package Quantity  
Product Selection - Page 4-10  
Rockwell Automation  
4-25  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Accessories  
Modules: Timer  
Description  
For Use with  
Cat. No.  
PQ  
Electronic Star-Delta Timing Relay  
Output Y picks up when the supply voltage is applied and resets again after time t.  
After a fixed changeover time t output relay picks up and remains energised until  
u
the supply voltage is interrupted.  
Circuit Diagram Single Selecta-  
ble Timing Range  
Use the catalogue  
number with the ap-  
propriate code.  
22.5 mm width  
700-FSY2U23  
on request:  
700-FSY2A40  
4
100-M, 100-C,  
CAB6  
Supply Voltage (A1/A2)  
1
Timing range ➊  
U23  
24…48 VDC  
C
D
E
F
0.5…10 s  
1.5…30 s  
0.05…1 min  
0.15…3 min  
0.5…10 min  
24…240 VAC, 50/60 Hz  
346…440 VAC, 50/60 Hz  
A1/A2  
U
A40  
t
17/18  
17/28  
tu=50...65 ms  
G
LED  
L
A1  
A2  
17  
Multiple Adjusta-  
ble Timing Ranges  
0.15 s…10 min  
17.5 mm width  
100-M, 100-C,  
CAB6  
(3s)  
0.15…3 s  
700-FEY2QU23  
1
18 28  
Supply Voltage (A1/A2)  
N
(10s) 0.5…10 s  
(1mn) 0.05…1 min  
(10mn) 0.5…10 min  
U23  
24…48 VDC  
24…240 VAC, 50/60 Hz  
~
S1  
O / I  
1
2
Timer  
Pick-up Delay  
After the set time has elapsed, the timer  
operates and the contactor in series is  
energised.  
100-M with  
110…250 V  
50/60 Hz /  
10  
1…3 s  
1…30 s  
196-MT3S  
196-MT30S  
110…250 VDC  
K1  
N
Setting Time  
Y Contactor  
1…30 s  
100-M with  
110…120 V  
50/60 Hz  
~
196-MTSDA1  
S1  
O / I  
Timer for Y-Switching  
1
After the set time has elapsed, the K3  
contactor (Y) is de-energised and then  
after a time of 90 ± 30 ms the K2 con-  
tactor () is energised.  
K2  
100-M with  
220…250 V  
50/60 Hz  
10  
1…30 s  
1…30 s  
196-MTSDA2  
196-MTSDA3  
2
Y
K3  
Y
K2  
100-M with  
48 V  
K1  
N
K2  
K3  
Y
50/60 Hz  
67 55  
Pick-up Delay  
0.3…30 s  
100-C with  
AC control  
100-FPTA30  
100-FPTA180  
Pneumatic Timer  
1.8…180 s  
Pneumatic timing contacts switch after  
the set time; the contacts on the main  
contactor operate without delay.  
56  
68  
1
65 57  
Drop-out Delay  
0.3…30 s  
1.8…180 s  
Continuous adjustment range  
All 100-C  
100-FPTB30  
100-FPTB180  
58  
66  
PQ = Package Quantity  
Product Selection - Page 4-10  
4-26  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Accessories  
Modules: Timer  
Description  
Circuit Diagram  
For Use with  
Cat. No.  
PQ  
100-ETA3  
100-ETA30  
100-ETA180  
100-C with  
110…240 V 50/60 Hz  
110…250 VDC  
L
S
Electronic Timing Modules  
Delay of the contactor magnetic coil  
A1  
Pick-up Delay  
Continuous adjustment range  
High repeat accuracy  
A1  
K1M  
0.1…3 s  
1…30 s  
10…180 s  
1
100-ETAZJ3  
100-ETAZJ30  
100-ETAZJ180  
A2  
100-C with  
24…48 VDC  
N
100-ETA  
L
The contact closes after the delay time  
elapses.  
A1  
4
t
A1 (K1M)  
100-ETBKJ3  
100-ETBKJ30  
100-ETBKJ180  
L
100-C09…C37 with  
24 V 50/60 Hz  
S
A1 B2  
Drop-out  
Delay  
100-ETB  
After interruption of the control signal, the  
contactor is switched off after the delay time  
elapses.  
A1  
K1M  
A2  
1
0.3…3 s  
1…30 s  
10…180 s  
100-ETB3  
100-ETB30  
100-ETB180  
100-C with  
110…240 V 50/60 Hz  
N
L
t
B2  
A1 (K1M)  
L
S
D1  
Y1  
100-ETY  
Setting Time  
Y Contactor  
D
Y
A1  
A1  
Y
A2  
A1  
A2  
After the set Y time elapses the K3 contact  
(Y) switches off and the K2 Contactor ()  
switches on (Switching delay t 90 ms).  
100-C with  
110…240 V 50/60 Hz  
H
D
100-ETY30  
1
A2  
N
1…30 s  
L
H A1  
Y A1  
D A1  
t  
t
PQ = Package Quantity  
Product Selection - Page 4-10  
Rockwell Automation  
4-27  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Accessories  
Modules: Mechanical Interlocks  
Description  
Circuit Diagram  
For Use with  
Cat. No.  
PQ  
Mechanical Interlock  
For interlocking of two adjacent contactors  
Without additional space requirement attachable  
from rear and recessed in top hat rail  
100-M with  
AC control  
199-MXM1  
10  
Mechanical Interlock  
For interlocking of two adjacent contactors  
Mechanical and electrical interlock in one module  
possible by means of integrated auxiliary contacts  
Contactors with AC control: 100-C09…100-C85 and  
Contactors with DC control: 100-C60…100-C85 can  
be interlocked any way desired  
100-C  
100-MCA00  
4
without auxiliary  
contacts  
21  
21  
Attention:  
Contactors with DC-control: 100-C09…100-C43 can  
only be interlocked with contactors of the same type!  
100-C  
CAB6  
100-MCA02  
22  
22  
with 2 N.C. auxiliary  
contacts  
9 mm connection piece included  
Mechanical Interlock  
For interlocking of two adjacent contactors  
One component for the interlock of all Bulletin CAB6  
contactors  
CMB6  
10  
For mounting between two contactors; no additional  
space required  
Options  
Cat. No. Suffix  
Description  
Ordering Example  
No Entry  
Single pack (1 piece, standard)  
Multi-pack (10 pieces)  
100-MCA00  
Package quantity  
M
100-MCA00M  
PQ = Package Quantity  
Product Selection - Page 4-10  
4-28  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Accessories  
Modules  
Description  
Circuit Diagram  
For Use with  
Cat. No.  
PQ  
L1~/L+  
0
Mechanical Latch  
I
In latching contactors, the contactor coil  
is immediately switched off after the  
contact on the latch closes (65-66); con-  
sequently, no holding current flows. Can  
be used for both AC and DC operation  
65  
57  
58  
13  
100-C with  
AC control  
K1R  
100-FL11  
1
K1M  
66  
A1  
14  
E1  
Auxiliary contacts 1 N.O. + 1 N.C.  
4
K1M  
N~/L-  
K1R  
A2  
E2  
Input  
Output  
Interface (electronic)  
L
Interface between the DC control signal  
(PLC) and the contactor AC operating  
mechanism.  
A1 E2 E1  
24 VDC  
12 VDC  
48 VDC  
100-JE  
Control voltage 18…30 VDC  
(10…15 mA)  
100-C,  
100S-C  
with  
A1  
A2  
110 …  
240 VAC  
K1M  
For coil voltages of 110…240 VAC  
Suitable for all Bulletin 100-C  
contactors  
100-JE12  
100-JE48  
AC control  
N
L
Switching capacity 200 VA  
Requires no overvoltage protection  
for the coils  
E1  
A1 (K1M)  
120 V AC, 2 inputs  
1 relay output  
24 V DC, 2 inputs  
1 relay output  
24 V DC, 2 inputs  
1 transistor output  
120 V AC, 4 inputs  
2 relay outputs  
24 V DC, 4 inputs  
2 relay outputs  
100-DNY21R  
100-DNY22R  
100-DNY22S  
100-DNY41R  
100-DNY42R  
DeviceNet System Accessory Mod-  
ule  
• Includes complete terminal connector  
set  
• Screw- or snap-on mounting to 35  
mm DIN Rail EN 50 022  
• For product information, see chapter  
15 (description, specifications and  
dimensions)  
1
24 V DC, 4 inputs  
2 transistor outputs  
100-DNY42S  
Options  
Cat. No. Suffix  
e.g. KJ  
Description  
Ordering Example  
100-FL11KJ  
100-JE  
Voltage suffix code  
Voltage suffix code from table below  
Single pack (1 piece, standard)  
Multi-pack (10 pieces)  
No Entry  
M
Package quantity  
100-JEM  
Voltage Suffix Code for AC Control  
100-  
110  
200- 200- 208-  
[V] 12  
24  
32  
36  
42  
48  
100  
110 120  
127  
200  
220  
230 240  
50 Hz  
60 Hz  
50/60 Hz  
(R)  
(Q)  
(K)  
(J)  
KJ  
(V)  
(W)  
(V)  
(X)  
(Y) (KP)  
(X)  
KY (KP)  
(KP)  
(D)  
KD  
(P)  
(D)  
(S)  
(KG)  
(KG)  
(KG)  
(KL)  
(L)  
100-FL11  
220-  
230  
230-  
240  
380-  
400  
400-  
415  
[V]  
230  
240 277 347 380  
400  
440  
480  
500  
550 600  
50 Hz  
60 Hz  
50/60 Hz  
(F)  
KF  
(VA)  
(T)  
(A)  
(KA)  
(T)  
(I)  
(E)  
(N)  
KN  
(G)  
(B)  
(N)  
(KB)  
(B)  
(M)  
(C)  
(C)  
Price Adder for:  
Type  
100-FL11  
Available Control Voltages  
No Surcharge  
Special control voltages  
12…500 V 50 Hz / 12…600 V 60 Hz  
> 20 pieces  
( ) Control voltages in parentheses: No inventory  
PQ = Package Quantity  
Product Selection - Page 4-10  
Rockwell Automation  
4-29  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Accessories  
Modules: Suppressor Modules  
Circuit  
Description  
For Use with  
Cat. No.  
PQ  
Diagram  
RC Module  
AC control  
24…48 VAC  
110…240 VAC  
24…48 VAC  
110…280 VAC  
380…480 VAC  
199-MSMA48  
199-MSMA1  
199-MSMNA48  
199-MSMNA280  
199-MSMNA480  
199-MSMD1  
2-wire version  
10  
100-M  
Suppressor Module for 100-M05  
/ M09/M12 Contactors  
For limiting surge voltage when  
coil circuits are interrupted.  
2-wire version  
Diode Circuit  
DC control  
12…250 VDC  
4
10  
10  
100-M  
199-MSMD2  
Varistor Circuit  
AC/DC control  
12…55 VAC / 12…77 VDC  
56…136 VAC / 78…178 VDC  
137…277 VAC / 181…350 VDC  
RC Module  
199-MSMV4  
199-MSMV5  
199-MSMV6  
100-M  
RC 24…48 VAC  
100-FSC48W  
100-FSC280W  
100-FSC480W  
100-FSC48  
100-FSC280  
100-FSC480  
2-wire version  
RC 110…280 VAC  
RC 380…480 VAC  
24…48 V 50/60 Hz  
110…280 V 50/60 Hz  
380…480 V 50/60 Hz  
Diode Circuit  
100-C,  
100S-C with  
AC control  
2-wire version 100-FSD250W  
100-C,100S-C  
Suppressor Module  
12…250 VDC  
with  
100-FSD250  
for 100-C Contactors  
For limiting switching overvoltage  
of the solenoids.  
DC control  
Varistor Circuit  
12…55 VAC / 12…77 VDC  
56…136 VAC / 78…180 VDC  
137…277 VAC / 181…350 VDC  
278…575 VAC  
12…55 VAC / 12…77 VDC  
56…136 VAC / 78…180 VDC  
137…277 VAC / 181…350 VDC  
278…575 VAC  
100-FSV55W  
2-wire version 100-FSV136W  
100-FSV277W  
Can be plugged into coil termi-  
nals of all 100-C contactors  
100-FSV575W  
100-C,  
100S-C with  
AC / DC  
100-FSV55  
100-FSV136  
100-FSV277  
100-FSV575  
control  
Contact Safety Control  
All  
100-C  
24…250 VDC  
100-FCC250W  
RC Module (AC control)  
21…48 V 50 Hz / 24…55 V 60 Hz  
95…110 V 50 Hz / 110…127 V 60 Hz  
190…240 V 50 Hz / 220…277 V 60 Hz  
380…550 V 50 Hz / 440…575 V 60 Hz  
Varistor-Modul  
for contactors with conventional  
control  
55 VAC  
56…136 VAC  
137…277 VAC  
278…575 VAC  
for contactors with electronic control CAB6-105-EI…  
CRCB6-48  
CRCB6-110  
CRCB6-240  
CRCB6-550  
CAB6-85…  
CAB6-140  
10  
Suppressor Module  
for CAB6 Contactors  
For limiting surge voltage when  
coil circuits are interrupted.  
Can be plugged into all CAB6  
contactors  
CRVB6-55  
CRVB6-136  
CRVB6-277  
CRVB6-575  
CAB6-85…  
CAB6-140  
Integrated EI- and DC control  
in the protective circuit, or  
delivered with separate sup-  
pressor module  
10  
24…28 VAC  
CAB6-250-EI  
CAB6-105-EI…  
CAB6-300-EI  
CRVB6-40  
ForovervoltagecategoryIV(IEC  
947 for CAB6...-EI) e.g., lightning  
protection requirements  
24…28 VDC  
48…72 VDC  
43…65 VAC  
208…277 VAC ➊  
380…400 VAC  
CRVB6-55  
CRVB6-75  
CRVB6-550  
CRVB6-460  
CAB6-105-EI…  
CAB6-420-EI  
Options  
Cat. No. Suffix  
Description  
Ordering Example  
100-FSC48  
No Entry  
Single pack (1 piece, standard)  
Multi-pack (10 pieces)  
Package quantity  
M
100-FSC48M  
Product Selection - Page 4-10  
4-30  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Accessories  
Mounting Materials  
Description  
Cat. No.  
PQ  
Adapter  
196-MTM  
10  
For easy, toolless mounting of timers on to DIN Rails EN 50 022-35 and G Rails  
100-S0  
100-S9  
Connection Pieces  
To link contactors (100-C) into combinations  
Single wedge  
Wedge-type connector9 mm  
0 mm  
10  
1
Terminal Blocks  
CAB6-HB1  
CAB6-HB2  
CAB6-HB3  
For CAB6-85 / CAB6-105  
For CAB6-105-EI / CAB6-170-EI  
For CAB6-210-EI…CAB6-420-EI  
Set of 2  
Protection class IP20 per IEC 529 and  
DIN 40 050  
4
For CAB6-85, CAB6-105  
CAB6-105-HU  
CAB6-170-HU  
825-ML630  
Terminal Blocks UL / CSA  
Set of 3  
For CAB6-140, CAB6-105-EI…CAB6-170-EI  
For CAB6-210-EI, CAB6-250-EI,  
CAB6-300-EI, CAB6-420-EI  
1
CAB6-AT  
CAB6-AT2  
Control Circuit Terminal  
For connecting to CAB6-85…170-EI  
For connecting to CAB6-210-EI…420-EI  
10  
2
2 x 2.5 mm  
Single Covers  
CAB6-HA1  
CAB6-HA2  
CAB6-HA3  
For CAB6-85, CAB6-105  
For CAB6-140, CAB6-105-EI…CAB6-170-EI  
For CAB6-210-EI…CAB6-420-EI  
Set of 2  
1
Protection class IP10 per IEC 529 and  
DIN 40 050  
For CAB6-85…CAB6-170-EI  
For direct-on-line starter  
For reversing or two-speed starters  
For Y-or Dahlander starters  
CAB6-105-PS  
CAB6-105-PU  
CAB6-105-PY  
Mounting Plate  
Galvanised passivated steel plate for  
combination  
1
For CAB6-210-EI…CAB6-420-EI  
For direct-on-line starter  
For reversing or two-speed starters  
For Y-or Dahlander starters  
CAB6-250-PS  
CAB6-250-PU  
CAB6-250-PY  
Cover to Protect against Manual Operation  
Protection against unintended manual  
operation  
For contactors and auxiliary contacts in safety  
circuits  
100-SCC  
100-SCF  
For 100-C09..100-C85  
For 100-FA, 100-FB, 100-FC, 100-FP, 100-FL  
PQ = Package Quantity  
Product Selection - Page 4-10  
Rockwell Automation  
4-31  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Accessories  
Mounting Materials  
Description  
For Use with  
Cat. No.  
PQ  
Connects:  
Connection Modules  
Bulletin 140-M-C circuit breakers with Bulletin  
100-M miniature contactors  
140M-C-PEM12  
The connection mod-  
ule allows a safe and  
easy electrical and  
mechanical connec-  
tion of contactor and  
circuit breaker  
Connects:  
Bulletin 140-MN circuit breakers with Bulletin  
100-M miniature contactors  
140-KCD4  
140-NW23  
10  
For DOL, reversing,  
and star-delta start-  
ers  
Connects:  
4
Bulletin 140-MN circuit breakers with Bulletin  
100-C contactors  
Without buttons  
100-C09…C23 198E-AYMN2  
Enclosures  
198E-AYMU1  
100-C09…C23 198E-AYMU2  
198E-AYMU4  
With blue RESET button  
With green and red buttons: START / STOP, RESET  
With green and extended red buttons: START / STOP, RESET  
For Bulletin 100-C  
contactors with Bulletin  
overload relays 193-E  
198E-AYNU1  
100-C30…C37 198E-AYNU2  
198E-AYNU4  
With blue RESET button  
With green and red buttons: START / STOP, RESET  
With green and extended red buttons: START / STOP, RESET  
1
For DOL starters  
Protection Class IP66  
Prestampings for two  
pilot lights  
198E-AYMU3  
100-C09…C23  
With white and black buttons: START / STOP, RESET  
With white and extended black buttons: START / STOP, RESET  
198E-AYMU5  
198E-AYNU3  
100-C30…C37  
With white and black buttons: START / STOP, RESET  
With white and extended black buttons: START / STOP, RESET  
198E-AYNU5  
red  
120 V  
240 V  
400 V  
140-LR120  
140-LR240  
140-LR400  
140-LG120  
Pilot Light  
green 120 V  
• Mounting with plug-in coupling in upper enclosure part  
• Connection cable length 180 mm  
240 V 198E-AY  
140-LG240  
140-LG400  
140-LW120  
140-LW240  
140-LW400  
10  
400 V  
white 120 V  
240 V  
Incl. glow lamp  
400 V  
Auxiliary Contact (START)  
For use with Cat. No. 198E-AY... enclosure  
100-C  
100-SD10  
Options  
Cat. No. Suffix  
Description  
Ordering Example  
140M-C-PEM12  
140M-C-PEM12M  
100-SD10  
No Entry  
M
Single pack (1 piece, standard quantity)  
Multi-pack (20 pieces)  
Package quantity  
No Entry  
M
Single pack (1 piece, standard quantity)  
Multi-pack (10 pieces)  
Package quantity  
100-SD10M  
PQ = Package Quantity  
Product Selection - Page 4-10  
4-32  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Accessories  
Mounting Materials  
Connection Kits  
Description  
Cat. No.  
PQ  
Connection kits ease the wiring of reversing and star-delta starters, help to prevent wiring errors and therefore consider-  
ably contribute to cost minimizing.  
Reversing switching  
100-M  
140-KCR4  
Connection Kits  
For reversing switching  
For star-delta switching  
10  
Star-Delta switching  
Reversing switching  
100-M  
140-KCSD4  
4
100-C09…100-C23  
100-C30…100-C37  
100-C43  
105-PW23  
105-PW37  
105-PW43  
105-PW85  
Connection Kits  
100-C60…100-C85  
For reversing switching  
For star-delta switching  
1
Star-Delta switching  
100-C09…100-C23  
100-C30…100-C37  
100-C43  
100-C60…100-C72  
100-C85  
170-PW23  
170-PW37  
170-PW43  
170-PW72  
170-PW85  
For Bulletin CAB6-85 … CAB6-170-EI Contactors  
2
45 mm input connections (for CAB6-..HU)  
CAB6-105-VLHU  
CAB6-105-VLHB  
CAB6-105-VT  
2
50 mm input connections (for CAB6-..HB)  
2
45 mm output connections (for CAB6-..HU)  
2
CAB6-105-VTHB  
CAB6-105-VYU  
50 mm output connections (for CAB6-..HB)  
«Neutral bridge» for CAB6-85…CAB6-170-EI  
For Bulletin CAB6-210-EI … CAB6-420-EI Contactors  
2
Connecting Sets  
120 mm input connections (for CAB6-..HB3 and CAB6-..HU)  
1
CAB6-250-VL  
CAB6-250-VT  
CAB6-250-VTHB  
CAB6-250-VY  
CAB6-250-VT  
2
120 mm output connections (for CAB6-..HU)  
2
120 mm output connections (for CAB6-..HB)  
2
For Y-contactor CAB6-140-EI…CAB6-170-EI; 80 mm  
For Y-contactor CAB6-210-EI…CAB6-250-EI; 120 mm  
2
For Y-contactor  
2
CAB6-250-VTHB  
CAB6-250-VYU  
CAB6-210-EI…CAB6-250-EI; 120 mm (for CAB6-..HB)  
«Neutral bridge» for CAB6-210-EI…CAB6-420-EI  
Labelling Material  
Renewal Parts  
• Uniform labelling materials for contactors, motor protection devices, timing relays, and circuit breakers  
Product information and ordering statements see chapter 3  
Description  
For Use with  
Cat. No.  
PQ  
CAB6-85  
CAB6-105  
CAB6-85-ARC  
CAB6-105-ARC  
CAB6-105-EI  
CAB6-140-EI  
CAB6-170-EI  
CAB6-210-EI  
CAB6-250-EI  
CAB6-300-EI  
CAB6-420-EI  
CAB6-85  
CAB6-105-EI-ARC  
CAB6-140-EI-ARC  
CAB6-170-EI-ARC  
CAB6-210-EI-ARC  
CAB6-250-EI-ARC  
CAB6-300-EI-ARC  
CAB6-420-EI-ARC  
CAB6-85-CONT-1  
Arc Chambers for Contactors  
• For 3-Pole CAB6 contactors  
1
CAB6-105  
CAB6-105-EI  
CAB6-140  
CAB6-140-EI  
CAB6-170-EI  
CAB6-210-EI  
CAB6-250-EI  
CAB6-300-EI  
CAB6-420-EI  
CAB6-105-CONT-2  
CAB6-105-EI-CONT-22  
CAB6-140-CONT-33  
CAB6-140-EI-CONT-3  
CAB6-170-EI-CONT-4  
CAB6-210-EI-CONT-5  
CAB6-250-EI-CONT-6  
CAB6-300-EI-CONT-7  
CAB6-420-EI-CONT-8  
Main Contacts for Contactors  
1
Set for 3-Pole CAB6 contactors  
Product Selection - Page 4-10  
Rockwell Automation  
4-33  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Accessories  
Renewal Parts: Coils for Bulletin 100-C, 100S-C Contactors  
100-C09… 100-C23…  
100-C16 100-C37  
100-C60…  
100-C85  
100-C09… 100-C23…  
100-C16 100-C37  
100-C60…  
100-C85  
AC  
Coil  
DC  
DC Control Voltage Coil  
Code  
100-C43  
100-C43  
AC Control  
Voltage  
4
Code  
PQ = 10  
PQ = 1  
PQ = 10  
PQ = 1  
50 Hz  
60 Hz  
50/60 Hz  
Cat. No. Cat. No. Cat. No. Cat. No.  
VDC  
Cat. No. Cat. No. Cat. No. Cat. No.  
12 V  
Q
R
TA006  
TA404  
TA013  
TA407  
TA855  
TA481  
TA410  
TA482  
TA414  
TA860  
TA861  
TA473  
TA856  
TA425  
TA428  
TA862  
TA864  
TA296  
TA474  
TA441  
TA851  
TA440  
TA480  
TA858  
TA065  
TA067  
TA071  
TC006  
TC404  
TC013  
TC407  
TC855  
TC481  
TC410  
TC482  
TC414  
TC860  
TC861  
TC473  
TC856  
TC425  
TC428  
TC862  
TC864  
TC296  
TC474  
TC441  
TC851  
TC440  
TC480  
TC858  
TC065  
TC067  
TC071  
TD006  
TD404  
TD013  
TD407  
TD855  
TD481  
TD410  
TD482  
TD414  
TD860  
TD861  
TD473  
TD856  
TD425  
TD428  
TD862  
TD864  
TD296  
TD474  
TD441  
TD851  
TD440  
TD480  
TD858  
TD065  
TD067  
TD071  
TE006  
TE404  
TE013  
TE407  
TE855  
TE481  
TE410  
TE482  
TE414  
TE860  
TE861  
TE473  
TE856  
TE425  
TE428  
TE862  
TE864  
TE296  
TE474  
TE441  
TE851  
TE440  
TE480  
TE858  
TE065  
TE067  
TE071  
ZR  
TA766  
TC766- TD766-  
TE766M  
9 V ➊  
12 V  
24 V  
integr. diode DR  
24 V  
J
ZQ  
TA708  
TC708  
TD708  
12 V  
24 V ➊  
K
integr. diode DQ  
TE708M  
24 V  
KJ  
V
ZJ  
TA714  
TC714  
TD714  
32 V  
36 V  
42 V  
48 V  
36 V  
48 V  
integr. diode DJ  
TA714M TC714M TD714M TE714M  
W
X
ZW  
TA719  
TC719  
TD719  
TE719M  
36 V  
48 V  
60 V  
64 V  
72 V  
80 V  
110 V  
115 V  
125 V  
220 V  
integr. diode DW  
Y
ZY  
TA724  
TC724  
TD724  
48 V  
KY  
KP  
D
integr. diode DY  
TE724M  
100 V  
110 V  
100…110V  
120 V  
ZZ  
TA774  
TC774  
TD774  
integr. diode DZ  
TE774M  
110 V  
KD  
P
ZB  
TA727  
TC727  
TD727  
120 V  
127 V  
200 V  
integr. diode DB  
TE727M  
S
ZG  
TA728  
TC728  
TD728  
200…220V  
KG  
integr. diode DG  
TE728M  
200…230 V KL  
ZE  
TA729  
TC729  
TD729  
208…240 V  
240 V  
L
A
F
integr. diode DE  
TE729M  
220 V  
ZD  
TA733  
TC733  
TD733  
220…230 V  
integr. diode DD  
TE733M  
230 V  
240 V  
KF  
VA  
T
ZP  
TA734  
TC734  
TD734  
230…240 V  
240 V  
integr. diode DP  
TE734M  
277 V  
ZS  
TA737  
TC737  
TD737  
KA  
I
integr. diode DS  
TE737M  
347 V  
380 V  
440 V  
ZA  
TA747  
TC747  
TD747  
E
integr. diode DA  
TE747M  
380…400 V  
N
ZF  
TA749  
TC749  
TD749  
230 V  
250 V  
diode circuit  
included  
400 V  
440 V  
KN  
G
TA863  
TA457  
TA475  
TC863  
TC457  
TC475  
TD863  
TD457  
TD475  
TE863  
TE457  
TE475  
DF  
ZD  
DT  
TA751  
TC751  
TD751  
TE749F  
400…415 V  
440 V  
diode circuit  
included  
480 V  
600 V  
B
TE751F  
KB  
M
TA859  
TA479  
TA476  
TC859  
TC479  
TC476  
TD859  
TD479  
TD476  
TE859  
TE479  
TE476  
500 V  
550 V  
C
Price Adder for:  
Type  
Available Control Voltages  
No Surcharge  
100-C09 … 100-C85  
For special voltages, please contact sales office  
12…500 V 50 Hz, 12…600 V 60 Hz,  
12 … 250 VDC  
Special control voltages  
> 20 pieces  
Extended operating limits 0.65…1.3 x U  
Extended operating limits 0.7…1.25 x U  
s
s
PQ = Package Quantity  
Product Selection - Page 4-10  
4-34  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Accessories  
Renewal Parts: Coils and Supply Modules for Bulletin CAB6 Contactors  
Description  
Variations  
For Use with  
Cat. No.  
PQ  
AC control  
Conventional  
CAB6-85…CAB6-140  
CAB6-105-COIL-  
CAB6-105-EI…CAB6-250-EI (24…28 V 50/60 Hz) CAB6-250-EI-COIL-05  
Electronic CAB6-105-EI…CAB6-300-EI  
CAB6-300-EI-COIL-  
CAB6-420-EI-COIL-  
CAB6-420-EI  
DC control  
CAB6-85…CAB6-140  
Conventional  
CAB6-105-COIL-  
4
Set:  
Coils and Supply Modules  
for CAB6 Contactors  
For replacement only  
1
CAB6-105-EI…CAB6-300-EI  
CAB6-300-EI-COIL-  
Electronic ➊  
CAB6-420-EI  
CAB6-420-EI-COIL-  
Options  
Voltage suffix code  
Ordering Example  
Cat. No. Suffix  
Description  
e.g. 54  
Voltage suffix code from table below  
CAB6-105-COIL-54  
Voltage Suffix Codes for AC Control  
220-  
380-  
440-  
460  
[V] 24  
28  
48  
55  
110 127  
230 240 260 277  
415  
480  
230  
13  
400  
16  
50 Hz  
05  
05  
08  
08  
10  
10  
54  
(15)  
13  
(15)  
(17)  
16  
(17)  
CAB6-85…CAB6-140 ➊  
60 Hz  
50/60 Hz  
(48)  
(55)  
24-  
28  
43- 110- 208- 380-  
65  
08  
08  
130 277 400  
CAB6-105-EI…CAB6-250-EI  
50/60 Hz  
05  
10  
10  
16  
16  
14  
14  
CAB6-300-EI…CAB6-420-EI 50/60 Hz  
Voltage Suffix Codes for DC Control  
[V] 24  
48  
110 220  
76 (86)  
CAB6-85…CAB6-140  
DC  
66  
(70)  
24-  
28  
48-  
72  
90- 110- 170- 190-  
135 135 255 255  
CAB6-105-EI…CAB6-300-EI  
CAB6-420-EI  
DC  
DC  
66  
(70)  
(70)  
76  
(86)  
76  
(86)  
Price Adder for:  
Type  
CAB6-85…CAB6-140 ➊  
Available Control Voltages  
No Surcharge  
21…550 V 50 Hz, 24…575 V 60 Hz,  
110…240 V 50/60 Hz, 24 … 240 VDC  
Special control voltages  
> 25 pieces  
( ) Control voltages in parentheses: No inventory  
50/60 Hz coil only available for CAB6-85 and 105  
Will be delivered only as set coil and supply module  
PQ = Package Quantity  
Product Selection - Page 4-10  
Rockwell Automation  
4-35  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
IEC Specifications  
100-M  
100-C, 100S-C  
05  
09  
12  
09  
12  
16  
23  
30  
37  
AC-1 Active Power Load, Switching of 3-phase  
Motors  
Ambient temperature 40 °C  
Ie  
500 V  
690 V  
1000 V  
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
1000 V  
[A]  
[A]  
20  
8
20  
8
20  
8
32  
32  
13  
13  
22  
23  
28  
38  
32  
32  
13  
13  
22  
23  
28  
38  
32  
32  
13  
13  
22  
23  
28  
38  
32 (40) ➊  
32 (40) ➊  
50  
50  
20  
21  
35  
36  
43  
60  
50  
50  
20  
21  
35  
36  
43  
60  
[A]  
13  
13  
22  
23  
28  
38  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
4
8.3  
14  
14  
17  
8.3  
14  
14  
17  
8.3  
14  
14  
17  
Ambient temperature 60 °C  
Ie  
500 V  
690 V  
1000 V  
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
1000 V  
[A]  
[A]  
16  
16  
16  
32  
32  
13  
13  
22  
23  
28  
38  
32  
32  
13  
13  
22  
23  
28  
38  
32  
32  
13  
13  
22  
23  
28  
38  
32  
32  
13  
13  
22  
23  
28  
38  
45  
45  
18  
19  
31  
32  
39  
54  
45  
45  
18  
19  
31  
32  
39  
54  
[A]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
6.4  
6.7  
11  
12  
14  
6.4  
6.7  
11  
12  
14  
6.4  
6.7  
11  
12  
14  
Switching of 3-phase Motors  
Ambient temperature 60 °C  
AC-2, AC-3, AC-4  
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
1000 V  
[A]  
[A]  
6.5  
6.5  
5.3  
5.3  
4
12  
12  
9
12  
12  
12  
12  
9
15  
15  
12  
12  
10  
7
20  
20  
16  
16  
14  
9
26.5  
26.5  
23  
35  
35  
30  
30  
25  
18  
10  
10  
15  
15  
15  
15  
38  
38  
[A]  
12 ➊  
12 ➊  
7
37  
[A]  
9
9
23  
37  
[A]  
7
7
20  
30  
[A]  
3
5
12  
21  
[A]  
3
4
230 V ➊  
240 V ➊  
400 V ➊  
415 V ➊  
500 V ➊  
690 V ➊  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
1.5  
1.5  
2.2  
2.2  
2.2  
3
5.5  
5.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
11  
11  
3
3
3
4
11  
4
5.5 ➊  
5.5 ➊  
4
4
5.5  
5.5  
5.5  
5.5  
18.5  
20  
4
4
11  
4
4
13  
20  
4
10  
18.5  
1000 V ➊  
AC-4 at approximately 200 000 operations  
230 V  
240 V  
[A]  
[A]  
2.3  
2.3  
2
3.9  
3.9  
3.3  
3.2  
3.9  
3.9  
3.3  
3.2  
4.3  
4.3  
4.3  
4.3  
4.3  
6.6  
6.6  
6.6  
6.6  
6.6  
9
9
10  
10  
10  
10  
10  
12  
12  
12  
12  
12  
14  
14  
14  
14  
14  
400 / 415V  
500 V  
[A]  
9
[A]  
1.9  
9
690 V  
[A]  
9
1000 V  
[A]  
2.2  
2.2  
4
230 V ➊  
240 V ➊  
400 V ➊  
415 V ➊  
500 V ➊  
690 V ➊  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
Sch/h  
0.37  
0.37  
0.75  
0.75  
0.75  
0.75  
0.75  
1.1  
1.1  
1.5  
0.75  
0.75  
1.1  
1.1  
1.5  
0.75  
0.75  
1.8  
1.8  
2.2  
3
1.5  
1.5  
3
2.2  
2.2  
4
3
3.7  
4
3
5.5  
5.5  
7.5  
10  
6.3  
6.3  
7.5  
11  
3
4
4
3.7  
5.5  
5.5  
7.5  
220  
5.5  
7.5  
1000 V ➊  
Max. switching frequency  
250  
250  
250  
250  
250  
200  
200  
200  
Values in ( ) with increased cross-section and cable lug  
Max. switching frequency  
Power ratings: Preferred values according to IEC 60072-1  
Product Selection - Page 4-10  
4-36  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
100-C, 100S-C  
CAB6  
43  
60  
72  
85  
-85  
-105(-EI)  
-140  
-140-EI  
-170-EI  
-210-EI  
-250-EI  
-300-EI  
-420-EI  
85  
85  
100  
100  
100  
100  
100  
100  
160  
160  
160  
64  
160  
160  
160  
64  
250  
250  
250  
100  
104  
173  
180  
217  
299  
433  
250  
250  
250  
100  
104  
173  
180  
217  
299  
433  
250  
250  
250  
100  
104  
173  
180  
217  
299  
433  
350  
350  
350  
139  
145  
242  
252  
303  
418  
606  
350  
350  
350  
139  
145  
242  
252  
303  
418  
606  
450  
450  
450  
179  
187  
312  
323  
390  
538  
779  
500  
500  
500  
199  
208  
346  
359  
433  
598  
866  
34  
35  
59  
61  
74  
102  
40  
40  
40  
4
42  
42  
42  
67  
67  
69  
69  
69  
111  
115  
139  
191  
277  
111  
115  
139  
191  
277  
72  
72  
72  
87  
87  
87  
120  
120  
120  
63  
63  
25  
26  
44  
45  
55  
75  
100  
100  
100  
100  
100  
100  
135  
.135  
135  
54  
135  
135  
135  
54  
210  
210  
210  
84  
210  
210  
210  
84  
210  
210  
210  
84  
300  
300  
300  
120  
125  
208  
216  
260  
359  
520  
300  
300  
300  
120  
125  
208  
216  
260  
359  
520  
380  
380  
380  
151  
158  
263  
273  
329  
454  
658  
425  
425  
425  
169  
177  
294  
305  
368  
508  
736  
40  
40  
40  
42  
42  
42  
56  
56  
87  
87  
87  
69  
69  
69  
94  
94  
145  
151  
182  
251  
364  
145  
151  
182  
251  
364  
145  
151  
182  
251  
364  
72  
72  
72  
97  
97  
87  
87  
87  
117  
161  
234  
117  
161  
234  
120  
120  
120  
44  
44  
43  
43  
38  
25  
13  
13  
22  
22  
25  
22  
62  
62  
72  
72  
72  
72  
67  
42  
22  
22  
40  
40  
45  
40  
85  
85  
85  
85  
80  
49  
25  
25  
45  
45  
55  
45  
85  
85  
85  
105  
105  
105  
140  
140  
140  
140  
140  
140  
170  
170  
170  
170  
170  
170  
65  
210  
210  
210  
250  
250  
250  
300  
300  
300  
420  
420  
420  
60  
60  
85 (95)105 (130)140 (155)140 (155)➊  
210 (227)250 (258)300 (315)420 (425)➊  
55  
85  
85  
33  
25  
25  
45  
105  
105  
40  
115  
115  
55  
140  
140  
55  
210  
250  
250  
95  
300  
420➊  
420➊  
160  
34  
210  
300  
80  
115  
18.5  
18.5  
32  
32  
45  
45  
55  
63  
80  
90  
132  
32  
45  
45  
55  
63  
80  
100  
132  
55  
75  
75  
90  
110  
132  
150  
160  
250  
132  
160  
220  
32  
45 (55)55 (75)80 (90)80 (90)➊  
100  
110  
160  
90  
125 (132)➊  
150  
160 (185)➊  
200  
250  
37  
55  
80  
45  
63  
100  
55  
80  
110  
75  
90  
132  
75  
300 ➊  
425 ➊  
220  
32  
200  
300  
110  
160  
16.5  
16.5  
16.5  
16.5  
16.5  
25.5  
25.5  
25.5  
25.5  
25.5  
31  
31  
31  
31  
31  
38  
38  
38  
38  
38  
43  
43  
43  
43  
43  
19  
13  
13  
22  
22  
25  
40  
22  
100  
50  
50  
50  
50  
50  
23  
15  
15  
25  
25  
32  
45  
30  
100  
60  
60  
60  
60  
67  
67  
67  
67  
67  
43  
20  
22  
37  
37  
45  
63  
55  
100  
85  
85  
85  
85  
85  
60  
25  
25  
45  
50  
55  
80  
80  
50  
105  
105  
105  
105  
105  
72  
140  
140  
140  
140  
140  
85  
170  
170  
170  
170  
170  
105  
55  
60  
60  
60  
60  
60  
60  
37  
37  
4
6.3  
7.5  
13  
7.5  
7.5  
15  
17  
20  
25  
11  
11  
20  
20  
25  
32  
17  
17  
32  
45  
4
18.5  
32  
18.5  
32  
32  
45  
55  
7.5  
7.5  
10  
55  
75  
90  
13  
32  
32  
55  
80  
100  
110  
160  
150  
50  
15  
40  
40  
75  
100  
132  
110  
50  
15  
22  
55  
55  
100  
100  
50  
50  
50  
200  
120  
120  
120  
100  
100  
415 V: values in ( ) AC-3 and AC-4 lifespan -25 %  
Value applies only to AC-2 and AC-3; AC-4: 360 A  
Product Selection - Page 4-10  
Rockwell Automation  
4-37  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
IEC Specifications  
100-M  
100-C, 100S-C  
05  
09  
12  
09  
12  
16  
23  
30  
37  
Star-Delta Starting  
230 V  
240 V  
400 V  
[A]  
[A]  
11  
11  
9.2  
9.2  
6.9  
3
21  
21  
16  
16  
12  
21  
21  
21  
21  
12  
21  
21  
26  
26  
21  
21  
17  
12  
35  
35  
28  
28  
24  
16  
10  
10  
13  
15  
15  
13  
46  
46  
40  
40  
35  
21  
61  
61  
52  
52  
43  
31  
66  
66  
64  
64  
52  
36  
20  
20  
32  
37  
32  
32  
[A]  
16  
415 V  
[A]  
16  
500 V  
[A]  
12  
4
690 V  
[A]  
8.6  
1 000 V  
230 V ➊  
240 V ➊  
400 V ➊  
415 V ➊  
500 V ➊  
690 V ➊  
1 000 V ➊  
[A]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
5.5  
5.5  
7.5  
7.5  
7.5  
5.5  
5.5  
10  
11  
7.5  
5.5  
5.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
10  
11  
11  
10  
13  
13  
20  
22  
22  
18.5  
17  
18.5  
25  
25  
25  
25  
3
4
4
4
Short-circuit Protection of Contactors  
without Motor Protection Relays  
Max. fuse gG per IEC 947-4-1  
Type «1» Coordination  
max. [A]  
max. [A]  
max. [A]  
25  
16  
25  
16  
25  
16  
50  
25  
25  
50  
35  
35  
50  
35  
35  
80  
40  
40  
125  
80  
125  
80  
Type «2» Coordination  
Type «2» Coordination  
400 V  
690 V  
80  
80  
Power ratings: Preferred values according to IEC 60072-1  
Product Selection - Page 4-10  
4-38  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
100-C, 100S-C  
CAB6  
43  
60  
72  
85  
-85  
-105(-EI)  
-140  
-140-EI  
-170-EI  
-210-EI  
-250-EI  
-300-EI  
-420-EI  
76  
76  
74  
74  
66  
43  
22  
22  
40  
40  
45  
40  
107  
107  
104  
104  
95  
125  
125  
125  
125  
116  
73  
147  
147  
147  
147  
139  
85  
147  
147  
147  
182  
182  
182  
242  
242  
242  
242  
242  
242  
294  
294  
294  
294  
294  
294  
112  
90  
364  
364  
364  
433  
433  
433  
520  
520  
520  
727  
727  
727  
147 (164)182 (225)242 (268)242 (268)➊  
364 (393)433 (447)520 (546)727 (736)➊  
147  
147  
55  
182  
182  
65  
199  
199  
96  
242  
242  
96  
364  
364  
139  
110  
125  
200  
220  
250  
355  
200  
433  
433  
165  
132  
150  
250  
250  
315  
425  
220  
520  
520  
200  
160  
160  
300  
727  
727  
277  
220  
250  
425  
4
59  
32  
37  
45  
45  
55  
75  
75  
32  
40  
50  
50  
63  
80  
80  
100  
160  
160  
200  
300  
160  
55  
63  
80  
80  
100  
132  
132  
55  
63  
80  
80 (90)100 (132)132 (160)132 (160)➊  
315 (335)425 (450)➊  
63  
80  
90  
100  
132  
75  
132  
160  
90  
132  
200  
132  
160  
220  
132  
375  
530  
280  
530  
750  
400  
55  
63  
80  
160  
100  
100  
250  
160  
160  
250  
160  
160  
250  
160  
160  
250  
200  
200  
250  
200  
200  
315  
250  
250  
315  
250  
250  
355  
315  
315  
500  
400  
400  
500  
400  
400  
630  
500  
500  
630  
500  
500  
415V: Values in ( ) AC-3 lifespan -25 %  
Product Selection - Page 4-10  
Rockwell Automation  
4-39  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
IEC Specifications  
100-M  
100-C, 100S-C  
05  
09  
12  
09  
12  
16  
23  
30  
37  
Switching of Power Transformers, AC-6a  
Inrush current  
= n  
Rated transformer  
n = 30  
230 V  
240 V  
400 V  
415 V  
[A]  
[A]  
2.9  
2.9  
2.4  
2.4  
1.8  
5.4  
5.4  
4.1  
4.1  
3.2  
5.4  
5.4  
5.4  
5.4  
3.2  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
10.9  
20  
20  
20  
20  
20  
20  
8
20  
20  
[A]  
20  
4
[A]  
20  
500 V  
690 V  
1000 V  
230 V  
[A]  
20  
[A]  
20  
[A]  
8
[kVA]  
[kVA]  
[kVA]  
[kVA]  
[kVA]  
[kVA]  
[kVA]  
[A]  
1.2  
1.2  
1.7  
1.7  
1.6  
2.2  
2.2  
2.8  
2.9  
2.7  
2.2  
2.2  
3.7  
3.9  
2.7  
4.3  
4.3  
4.3  
4.3  
240 V  
4.5  
4.5  
4.5  
4.5  
8.3  
14  
14  
17  
24  
30  
40  
8.3  
14  
14  
17  
24  
30  
40  
400 V  
7.5  
7.5  
7.5  
7.5  
415 V  
7.8  
7.8  
7.8  
7.8  
500 V  
9.4  
9.4  
9.4  
9.4  
690 V  
13  
13  
13  
13  
1000 V  
690 V  
690 V  
n = 20  
n = 15  
16.3  
22  
16.3  
22  
16.3  
22  
16.3  
22  
[A]  
Switching of 3-phase Capacitors, AC-6b  
Inductance of leads between capacitors  
in parallel: min. 6 µH  
(100-C09...-C30 contactors: min. 30 µH)  
Single capacitors 40 °C  
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
1 000 V  
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
1 000 V  
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
1 000 V  
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
1 000 V  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
8
8
8
8
8
8
8
8
8
8
8
8
5
5
5
5
5
5
5
5
5
5
5
5
8
8
8
8
8
8
8
8
8
8
8
8
5
5
5
5
5
5
5
5
5
5
5
5
8.5  
8.5  
10  
10  
10  
10  
9
9
14  
14  
14  
14  
12.5  
12.5  
12.5  
12.5  
20  
24  
20  
25  
20  
25  
20  
25  
60 °C  
8.5  
8.5  
10  
10  
10  
10  
9
12.5  
12.5  
20  
12.5  
12.5  
21.5  
22  
9
12.5  
12.5  
12.5  
12.5  
20  
20  
25  
20  
25  
Group capacitors 40 °C  
8
9
12.5  
12.5  
15  
14  
8
9
14  
8
10  
10  
10  
10  
20  
8
15  
20  
8
15  
20  
8
15  
20  
60 °C  
8
9
12.5  
12.5  
15  
12.5  
12.5  
20  
8
9
8
10  
10  
10  
10  
8
15  
20  
8
15  
20  
8
15  
20  
Product Selection - Page 4-10  
4-40  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
100-C, 100S-C  
CAB6  
43  
60  
72  
85  
-85  
-105(-EI)  
-140(-EI)  
-170-EI  
-210-EI  
-250-EI  
-300-EI  
-420-EI  
23  
23  
23  
23  
23  
23  
40.8  
40.8  
40.8  
40.8  
40.8  
40.8  
40.8  
40.8  
40.8  
40.8  
40.8  
40.8  
40.8  
40.8  
40.8  
40.8  
40.8  
40.8  
53  
53  
53  
53  
53  
53  
53  
21  
22  
37  
38  
46  
64  
92  
80  
107  
60  
60  
60  
60  
60  
60  
60  
24  
25  
42  
43  
52  
72  
104  
90  
120  
70  
70  
85  
85  
105  
105  
105  
105  
105  
105  
105  
42  
125  
125  
125  
125  
125  
125  
125  
50  
150  
150  
150  
150  
150  
150  
150  
60  
210  
210  
210  
210  
210  
210  
210  
84  
70  
85  
4
70  
85  
70  
85  
70  
85  
70  
85  
9.2  
10  
16  
17  
20  
27  
16  
16  
16  
28  
34  
17  
17  
17  
29  
35  
44  
52  
62  
87  
28  
28  
28  
48  
59  
73  
87  
104  
108  
130  
179  
260  
225  
300  
145  
151  
182  
251  
364  
315  
420  
29  
29  
29  
50  
61  
75  
90  
35  
35  
35  
61  
74  
91  
108  
149  
217  
188  
250  
49  
49  
49  
84  
102  
147  
128  
170  
125  
182  
158  
210  
121  
105  
140  
34.5  
46  
61.3  
82  
61.3  
82  
61.3  
82  
24  
25  
35  
35  
35  
35  
28  
29  
48  
50  
50  
50  
28  
29  
48  
50  
55  
55  
28  
29  
48  
50  
60  
60  
45  
48  
78  
80  
98  
133  
193  
33  
35  
58  
60  
73  
100  
145  
45  
47  
58  
60  
60  
60  
60  
33  
35  
58  
60  
60  
60  
60  
45  
48  
78  
80  
98  
133  
193  
33  
35  
58  
60  
73  
100  
145  
40  
45  
75  
78  
78  
78  
80  
35  
38  
58  
60  
73  
78  
80  
70  
73  
70  
73  
98  
98  
125  
131  
218  
226  
273  
376  
546  
106  
111  
184  
191  
230  
318  
461  
125  
131  
218  
226  
273  
356  
361  
106  
111  
184  
191  
230  
318  
361  
139  
145  
242  
252  
303  
418  
606  
119  
124  
206  
214  
258  
356  
515  
139  
145  
242  
252  
303  
418  
606  
119  
124  
206  
214  
258  
356  
515  
102  
170  
176  
212  
293  
424  
84  
102  
170  
176  
212  
293  
424  
84  
120  
125  
150  
208  
300  
60  
120  
125  
150  
208  
300  
60  
18  
18  
30  
30  
30  
30  
28  
29  
42  
42  
42  
42  
28  
29  
48  
50  
50  
50  
28  
29  
48  
50  
55  
55  
63  
63  
87  
87  
100  
105  
128  
175  
253  
70  
100  
105  
128  
175  
253  
70  
145  
151  
182  
251  
364  
98  
145  
151  
182  
251  
364  
98  
20  
20  
25  
25  
25  
25  
28  
29  
40  
40  
40  
40  
28  
29  
48  
50  
50  
50  
28  
29  
48  
50  
50  
50  
73  
73  
102  
170  
170  
172  
174  
177  
84  
102  
170  
176  
212  
247  
251  
84  
98  
120  
123  
123  
123  
125  
58  
98  
100  
100  
100  
58  
18  
18  
25  
25  
25  
25  
28  
29  
40  
40  
40  
40  
28  
29  
48  
50  
50  
50  
28  
29  
48  
50  
50  
50  
60  
60  
87  
87  
98  
100  
105  
123  
123  
125  
145  
151  
172  
174  
177  
145  
151  
182  
247  
251  
98  
100  
100  
100  
Product Selection - Page 4-10  
Rockwell Automation  
4-41  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
IEC Specifications  
100-M  
100-C, 100S-C  
05  
09  
12  
09  
12  
16  
23  
30  
37  
Switching of Lamps  
Gas discharge lamps AC-5a  
open  
closed  
[A]  
[A]  
18  
14.5  
18  
14.5  
18  
14.5  
22.5  
22.5  
25  
25  
28  
28  
29  
29  
40.5  
37  
45  
41  
Individually compensated:  
Max. capacitance at expected  
Short-circuit current of  
10 kA  
20 kA  
50 kA  
[µF]  
[µF]  
[µF]  
[A]  
750  
400  
750  
400  
750  
400  
1 000  
500  
200  
12  
1 000  
500  
200  
16  
1 000  
500  
200  
18  
1 000  
500  
200  
22  
2 700  
1 350  
540  
2 700  
1 350  
540  
4
Filament AC-5b  
230/240 V  
9.3  
9.3  
9.3  
30  
37  
Switching of Low Inductive Loads in Home Appliances and  
Similar Applications  
AC-7a  
230 V  
400 V  
440 V  
[A]  
[A]  
[A]  
32  
32  
32  
32  
32  
32  
32  
32  
32  
32  
32  
32  
45  
45  
45  
45  
45  
45  
Switching of Motor Load for Home Appliances  
AC-7b 230 V  
[A]  
[A]  
[A]  
10.5  
9
14  
12  
10  
19  
16  
23  
20  
18  
30  
30  
27  
400 V  
440 V  
7.5  
13.5  
Switching of Hermetically Sealed Cooling Compressor Motors  
- manual reset of overload release  
AC-8a  
400 V  
500 V  
690 V  
[A]  
[A]  
[A]  
12  
12  
8
16  
16  
10  
22  
22  
14  
32  
32  
20  
38  
38  
28  
45  
45  
35  
- automatic reset of overload release  
AC-8b  
400 V  
500 V  
690 V  
[A]  
[A]  
[A]  
5.5  
5.5  
5.5  
7
7
7
9.3  
9.3  
9.3  
12  
12  
12  
13  
13  
13  
14  
14  
14  
Switching of DC Loads  
non-inductive or slightly inductive loads or resistance  
furnaces DC-1 at 60 °C  
1 pole  
24 V  
48/60 V  
110 V  
220 V  
440 V  
24 V  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
6
4/1  
0.6  
0.2  
0.08  
6
9
6/1.5  
1
9
6/1.5  
1
25  
20  
6
25  
20  
6
32  
20  
6
32  
20  
6
45  
25  
8
45  
25  
8
0.3  
0.1  
9
0.3  
0.1  
9
1.5  
0.4  
25  
25  
25  
8
1.5  
0.4  
25  
25  
25  
8
1.5  
0.4  
32  
32  
32  
8
1.5  
0.4  
32  
32  
32  
10  
1
1.5  
0.4  
45  
45  
45  
10  
1
1.5  
0.4  
45  
45  
45  
10  
1
2 poles in series  
3 poles in series  
48/60 V  
110 V  
220 V  
440 V  
24 V  
6
8
8
4
6
6
0.8  
0.2  
6
1.2  
0.3  
9
1.2  
0.3  
9
1
1
1
25  
25  
25  
25  
3
25  
25  
25  
25  
3
32  
32  
32  
32  
3
32  
32  
32  
32  
3
45  
45  
45  
45  
3.5  
45  
45  
45  
45  
3.5  
48/60 V  
110 V  
220 V  
440 V  
6
9
9
6
9
9
3
0.4  
4
0.6  
4
0.6  
Shunt-wound Motors  
Starting, reverse current braking, reversing  
stepping DC-3, 60 °C  
3 poles in series  
24 V  
48/60 V  
110 V  
[A]  
[A]  
[A]  
[A]  
[A]  
5
4
9
6
9
6
25  
25  
20  
6
25  
25  
20  
6
32  
32  
25  
6
32  
32  
25  
10  
0.6  
45  
45  
30  
15  
0.6  
45  
45  
30  
15  
0.6  
2
3
3
220 V  
440 V  
0.8  
0.15  
1.2  
0.2  
1.2  
0.2  
0.6  
0.6  
0.6  
Series-wound Motors  
Starting, reverse current braking, reversing  
stepping DC-5, 60 °C  
3 poles in series  
24 V  
48/60 V  
110 V  
[A]  
[A]  
[A]  
[A]  
[A]  
5
2
9
3
9
3
25  
25  
20  
6
25  
25  
20  
6
32  
32  
25  
6
32  
32  
25  
10  
0.6  
45  
45  
30  
15  
0.6  
45  
45  
30  
15  
0.6  
0.6  
0.1  
1
1
220 V  
440 V  
0.1  
0.1  
0.6  
0.6  
0.6  
Short Time Withstand I  
60 °C  
CW,  
10 s  
[A]  
60  
96  
96  
170  
170  
170  
215  
300  
304  
Product Selection - Page 4-10  
4-42  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
100-C, 100S-C  
CAB6  
43  
60  
72  
85  
-85  
-105(-EI)  
-140(-EI)  
-170-EI  
-210-EI  
-250-EI  
-300-EI  
-420-EI  
77  
57  
81  
77  
85  
81  
90  
90  
144  
121.5  
144  
121.5  
225  
189  
225  
189  
315  
270  
315  
270  
405  
342  
420  
382.5  
3 200  
1 600  
640  
4 000  
2 000  
800  
4 000  
2 000  
800  
4 700  
2 350  
940  
107  
120  
140  
170  
273  
273  
300  
420  
4
43  
60  
70  
76  
63  
63  
63  
63  
63  
42  
72  
72  
56  
85  
85  
67  
100  
100  
80  
16  
16  
16  
24  
24  
24  
30  
30  
30  
35  
35  
35  
50  
30  
9
70  
40  
11  
2
80  
40  
11  
2
80  
40  
11  
2
120  
120  
120  
3
120  
120  
120  
3
210  
210  
210  
4
210  
210  
210  
4
1.5  
0.5  
50  
50  
50  
10  
1
0.5  
70  
70  
70  
15  
1.5  
90  
90  
90  
70  
5
0.5  
80  
80  
80  
15  
1.5  
90  
90  
90  
80  
5
0.5  
80  
80  
80  
15  
1.5  
100  
100  
100  
80  
5
0.6  
120  
120  
120  
120  
3
0.6  
120  
120  
120  
120  
3
1
1
210  
210  
210  
210  
4
210  
210  
210  
210  
4
63  
63  
63  
50  
4
120  
120  
120  
120  
11  
120  
120  
120  
120  
11  
210  
210  
210  
210  
11  
210  
210  
210  
210  
11  
63  
50  
35  
20  
0.6  
90  
70  
70  
25  
0.6  
90  
70  
70  
25  
0.6  
100  
80  
120  
120  
120  
120  
3
120  
120  
120  
120  
3
210  
210  
210  
210  
4
210  
210  
210  
210  
4
80  
30  
0.6  
63  
50  
35  
20  
0.6  
90  
70  
70  
25  
0.6  
90  
70  
70  
25  
0.6  
100  
80  
80  
80  
80  
80  
1.2  
80  
80  
80  
80  
1.2  
120  
120  
120  
120  
2
120  
120  
120  
120  
2
80  
30  
0.6  
375  
700  
700  
700  
1060  
1060  
1 390  
1 390  
2 300  
2 570  
2 800  
4 290  
Product Selection - Page 4-10  
Rockwell Automation  
4-43  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
Specifications  
100-M  
100-C, 100S-C  
05  
09  
12  
09  
12  
16  
23  
30  
37  
Resistance and Power Dissipation  
Main current circuit resistance  
Power dissipation by all circuits  
[m]  
5.5  
5.5  
1.3  
5.5  
2.4  
2.7  
2.7  
1.2  
2.7  
2.1  
2
2
2
at I AC-3/400 V  
e
[W]  
0.46  
0.66  
3.2  
5.4  
8.2  
Total power dissipation  
at I AC-3/400 V  
e
AC control  
DC control  
[W]  
[W]  
1.9  
3.0  
2.7  
3.8  
3.8  
4.9  
3.3  
6.7  
3.8  
7.2  
4.7  
8.1  
6.2  
8.4  
11.2  
17.4  
12.4  
14.6  
4
Load Carrying Capacity per UL/CSA  
Lloyd’s Register of Shipping  
Continuous current  
(open)  
[A]  
[A]  
12  
12  
12  
12  
12  
12  
25  
25  
25  
25  
30  
30  
30  
30  
45  
45  
50  
50  
(enclosed)  
Rated power  
3-phase motors, 60 Hz, enclosed  
(Direct-on-line) 1-phase  
115 V  
230 V  
200 V  
230 V  
460 V  
575 V  
[HP]  
[HP]  
[HP]  
[HP]  
[HP]  
[HP]  
[HP]  
[HP]  
[HP]  
[HP]  
0.5  
1
0.5  
1.5  
2
0.5  
2
0.5  
1.5  
2
0.5  
2
1
3
2
3
2
3
5
5
3-phase  
1.5  
1.5  
3
3
3
5
5
7.5  
10  
20  
25  
7.5  
10  
20  
25  
10  
10  
25  
30  
10  
10  
25  
30  
2
3
2
3
5
7.5  
15  
15  
5
5
7.5  
10  
3
5
7.5  
10  
3
10  
15  
5
3
5
7.5  
2
(Reversing combinations) 3-phase 200 V  
1.5  
1.5  
3
2
230 V  
2
3
2
3
5
7.5  
15  
15  
460 V  
5
7.5  
10  
5
7.5  
10  
10  
15  
575 V  
3
5
7.5  
Lifespan  
Mechanical  
AC control  
DC control  
AC-3 (400 V)  
[Mio. operations.  
[Mio. operations]  
[Mio. operations]  
10  
20  
10  
20  
10  
20  
13  
13  
13  
13  
13  
13  
13  
13  
13  
13  
13  
13  
Electrical  
0.7  
0.7  
0.7  
1.3  
1.3  
1.3  
1.3  
1.3  
1.3  
Weight  
AC control  
DC control  
[kg]  
[kg]  
0.16  
0.16  
0.16  
0.16  
0.16  
0.16  
0.39  
0.6  
0.39  
0.6  
0.39  
0.61  
0.39  
0.73  
0.48  
0.85  
0.49  
0.85  
Product Selection - Page 4-10  
4-44  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
100-C, 100S-C  
CAB6  
43  
60  
72  
85  
-85  
-105(-EI)  
-140(-EI)  
-170-EI  
-210-EI  
-250-EI  
-300-EI  
-420-EI  
1.5  
8.3  
0.9  
9.7  
0.9  
14  
0.9  
0.4  
8.7  
0.4  
0.42  
24.6  
0.42  
36.3  
0.22  
29.4  
0.22  
41.7  
0.18  
48.6  
0.15  
79.5  
19.5  
13.2 (13.8)  
11.5  
18.4  
11  
11  
13.8  
13.8  
17.5  
17.5  
18.2  
16.7  
22.7  
20.9  
34.5  
32.5  
46.5  
44.5  
39.4  
37.4  
51.7  
49.7  
58.6  
56.6  
89.5  
87.5  
4
63  
63  
90  
90  
90  
90  
100  
100  
178  
160  
178  
160  
250  
220  
250  
220  
350  
300  
350  
300  
420  
340  
500  
420  
3
5
5
7.5  
15  
25  
30  
60  
60  
25  
30  
60  
60  
7.5  
15  
25  
30  
60  
75  
25  
30  
60  
75  
10  
25  
15  
30  
40  
50  
7.5  
10  
15  
30  
30  
10  
15  
30  
30  
10  
15  
20  
40  
50  
15  
20  
40  
50  
15  
20  
25  
50  
60  
20  
25  
50  
60  
40  
40  
50  
60  
75  
100  
125  
250  
300  
100  
125  
250  
300  
150  
175  
350  
400  
117  
135  
278  
350  
40  
50  
60  
75  
100  
200  
250  
75  
75  
100  
125  
40  
150  
150  
50  
150  
200  
60  
100  
40  
40  
50  
60  
75  
100  
200  
250  
75  
100  
125  
150  
150  
150  
200  
100  
12  
13  
1
10  
10  
1
10  
10  
1
10  
10  
1
10  
10  
1
10  
10  
1
10  
10  
1
10  
10  
1
10  
10  
1
10  
10  
1
10  
10  
1
10  
10  
1
0.51  
1.0  
1.45  
1.47  
1.45  
1.47  
1.45  
1.47  
3.3  
3.3  
3.3 (3.8)  
3.3 (3.8)  
3.3 (3.8)  
3.3 (3.8)  
3.8  
3.8  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
7.5  
Product Selection - Page 4-10  
Rockwell Automation  
4-45  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
100-M  
100-C, 100S-C  
16 23  
05  
09  
12  
09  
12  
30  
37  
Terminal Cross Sections - Main Contacts  
Terminal type  
2
1. conductor [mm ]  
2
2. conductors [mm ]  
0.75 … 2.5  
0.75 … 2.5  
1 … 4  
1 … 4  
2.5 … 10  
2.5 … 10  
2
1. conductor[ [mm ]  
2
2. conductors [mm ]  
0.75 … 2.5  
0.75 … 2.5  
1.5 … 6  
1.5 … 6  
2.5 … 16  
2.5 … 16  
4
b max.  
c max.  
s max.  
o min.  
[mm]  
[mm]  
[mm]  
[mm]  
c
c
s
s
b
b
c
s
b
Recommended torque  
Cross section per UL/CSA  
With terminal lug kit  
[Nm]  
1 … 1.5  
18 … 14  
1 … 2.5  
16 … 10  
1.5 … 3.5  
14 … 6  
[AWG]  
Recommended torque  
[lb-in]  
7 … 15  
8.9 … 22  
13 … 31  
With Frame Terminal Block  
2
1. conductor [mm ]  
2
2. conductors [mm ]  
2
1. conductor [mm ]  
2
2. conductors [mm ]  
b max.  
s top  
[mm]  
[mm]  
[mm]  
s
s
b
b
s bottom  
Recommended torque[Nm]  
Cross section per UL/CSA  
top  
[AWG]  
[AWG]  
[lb-in]  
bottom  
Recommended torque  
Control Circuits  
100-M  
09  
100-C, 100S-C  
16 23  
05  
12  
09  
12  
30  
37  
Operating limits  
50 Hz, 60 Hz, 50/60 Hz  
pick-up  
dropout  
pick-up  
dropout  
[x Us]  
[x Us]  
[x Us]  
[x Us]  
0.85…1.1  
0.35…0.65  
0.85…1.1  
0.1…0.25  
0.85…1.1  
0.3…0.6  
0.8…1.1  
0.1…0.6  
DC control  
Pick-up and Holding Power  
50 Hz, 60 Hz, 50/60 Hz  
pick-up  
holding  
pick-up  
holding  
[VA/W]  
[VA/W]  
[W]  
22/20  
4/1.4  
2.5  
70/50  
8/2.6  
6.5  
70/50  
9/3  
80/60  
9/3  
DC control  
9.2  
9.2  
[W]  
2.5  
6.5  
9.2  
9.2  
Switching Delay  
AC  
closing delay  
opening delay  
opening delay  
closing delay  
opening delay  
[ms]  
[ms]  
[ms]  
[ms]  
[ms]  
[ms]  
[ms]  
15…40  
15…25  
15…25  
18…40  
6…12  
15…30  
10…60  
10…60  
40…70  
7…15  
15…30  
10…60  
10…60  
40…70  
7…15  
15…30  
10…60  
10…60  
50…80  
7…15  
With RC module  
DC  
Integrated protection circuitopening delay  
With diode openingdelay  
8…12  
14…20  
70…95  
17…23  
80…125  
17…23  
80…125  
35…50  
Pozidriv No. 2 / Blade No. 3 screw  
Pozidriv No. 2 / Blade No. 4 screw  
Hexagonal socket screw  
Hexagonal screw  
Product Selection - Page 4-10  
4-46  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
100-C, 100S-C  
60 72  
CAB6  
43  
85  
-85  
-105  
-105-EI  
-140(-EI)  
-170-EI  
-210-EI  
-250-EI  
-300-EI  
-420-EI  
2.5 … 16  
2.5 … 10  
2.5 … 35  
2.5 … 25  
2.5 … 25  
2.5 … 15  
2.5 … 50  
2.5 … 35  
4
20  
10  
25  
30  
15  
12.5  
2 x 5  
2 x 5  
6.1  
2 x 6  
8.3  
10.5  
16  
1.5 … 3.5  
14 … 6  
2 … 6  
14 … 2  
8…10  
10…12  
6…2/0  
6…250 MCM  
CAB6-170-HU ➊  
90…110  
8…600 MCM  
825-ML630 / CA 6-420-HU ➊  
130…150  
CAB6-105-HU ➊  
70…90  
13 … 31  
18 … 52  
CAB6-HB1 ➊  
CAB6-HB2 ➊  
CAB6-HB3 ➊  
16 … 35  
16 … 70  
16 … 35  
16 … 95  
25 … 240 ➊  
25 … 240  
16 … 50  
16 … 95  
16 … 50  
16 … 120  
25 … 300  
25 … 300  
16  
3 … 9  
3 … 12  
20  
3 … 9  
3 … 14  
25  
4 … 20  
4 … 20  
8 … 10  
10 … 12  
20 … 25  
No. 6 … 1 / 0 AWG  
No. 6 … 3 / 0 AWG  
70 … 90  
No. 6 … 1 / 0 AWG  
No. 4 AWG … 600 MCM  
No. 4 AWG … 600 MCM  
180 … 220  
No. 6 AWG … 250 MCM  
90 … 110  
100-C, 100S-C  
60 72  
CAB6  
-170-EI  
43  
85  
-85  
-105/-140  
-105-EI  
-140-EI  
-210-EI  
-250-EI  
-300-EI  
-420-EI  
0.85 ….1.1  
0.3 …0.6  
0.8 …1.1  
0.1 …0.6  
0.85 …1.1  
0.85 …1.1  
0.3 …0.5  
0.85 …1.1  
0.3 …0.5  
0.3 …0.6  
0.85 …1.1  
0.3 …0.6  
130/90  
10/3.2  
10.1  
200/110  
16/4.5  
200  
650/310  
50/10  
540  
370/243 ➊  
590/355 ➊  
15/7  
12/6  
190 ➊  
6
375 ➊  
7
10.1  
4.5  
8
15…30  
10…60  
10…60  
50…80  
7…15  
20…40  
10…60  
20…47  
6…12  
9…18  
27…47  
12…20  
12…20  
75…90  
30…60  
75…90  
30…60  
10…60  
20…40  
75…90  
30…60  
75…90  
30…60  
17…23  
80…125  
220 V 20…35  
> 220 V 80…125  
2
With CT(A)B6-150 / 200 min. 25 mm  
CAB6-HB3 not for use with CEFB1-41 / 42 and 825-MCM630 in preparation  
2
25 … 95 mm with sleeve per DIN 46228  
Electronic coil drives are controlled for minimizing performance, but this control may shortly require (< 1ms) peak load when attracting.This must  
be taken into account for the dimensioning of supply devices, all-or-nothing relays and cross-sections of coil supply lines. Please contact your  
nearest Rockwell Automation sales office for detailed information  
Product Selection - Page 4-10  
Rockwell Automation  
4-47  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
Auxiliary Contacts and Auxiliary Contact Blocks  
Auxiliary contact for 100-M  
Auxiliary contact for 100-C, 100S-C  
Auxiliary contact for CAB6  
Electronically  
compatible  
Internal  
Blocks  
Internal Front-mounted Side-mounted Conventional  
Switching of AC Loads  
AC-12 Ith  
at 40 °C  
at 60 °C  
[A]  
[A]  
16  
12  
10  
6
25  
10  
6
10  
6
16  
12  
0.1  
20  
at 250 V  
AC-15 at rated voltage of  
24 V  
42 / 48 V  
110 V  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
6
2
10  
10  
10  
10  
10  
6
6
6
3
3
5.5  
5
4
6
3
(1 … 100 mA)  
at  
230 V  
5.5  
5
3
240 V  
5
2
3
3 … 125 V  
400 V  
2.5  
2
1
3
2
3
415 V  
1
5
2.5  
1.6  
1
2
2.5  
1.6  
1
500 V  
1.25  
0.6  
2.5  
1
1.6  
0.75  
690 V  
Switching of DC Loads  
DC-12 L/R< 1 ms resistive loads at  
24 VDC  
[A]  
[A]  
[A]  
[A]  
[A]  
6
4
6
2
12  
9
12  
9
6
16  
9
48 VDC  
3.2  
110 VDC  
0.6  
0.2  
0.08  
0.6  
0.2  
0.08  
3.5  
0.55  
0.2  
3.5  
0.55  
0.2  
0.45  
0.18  
0.1  
3.5  
0.55  
0.2  
220 VDC  
440 VDC  
DC-14 L/R< 15 ms inductive loads with economy  
resistor in series at  
24 VDC  
[A]  
[A]  
[A]  
[A]  
[A]  
4
4
9
5
9
5
2
9
5
48 VDC  
2.5  
1.2  
1.6  
.3  
110 VDC  
0.4  
0.4  
2
2
2
220 VDC  
0.12  
0.05  
0.12  
0.05  
0.4  
0.16  
0.4  
0.16  
0.12  
0.05  
0.4  
0.16  
440 VDC  
DC-13 switching electromagnets at  
24 VDC  
[A]  
[A]  
[A]  
[A]  
[A]  
5
2
5
5
3
5
(1 … 100 mA)  
at  
48 VDC  
110 VDC  
0.6  
0.6  
2
2
1.5  
0.6  
0.3  
0.2  
2
0.45  
0.25  
0.04  
0.45  
0.1  
0.7  
0.25  
0.12  
0.7  
0.25  
0.12  
0.7  
0.25  
0.12  
3 … 125 V  
220 VDC  
440 VDC  
0.04  
Fuse gG  
Short-circuit protection with no  
Welding of contacts per IEC 947-5  
[A]  
[A]  
16  
16  
10  
10  
10  
10  
10  
10  
10  
10  
16  
16  
Safe isolation  
between load  
and auxiliary  
circuit 250 V  
between load and auxiliary  
circuit 500 V  
Min. Short-circuit switching capacity 17 V DIN 19240  
Auxiliary contacts  
[mA]  
5
5
5
5
5
5
1 ➊  
Load Carrying Capacity per UL/CSA  
Rated voltage  
AC  
[V]  
[A]  
max. 600  
max. 600  
10  
max. 600  
10 General  
purpose  
max. 250  
0.1  
Continuous rating  
40 °C  
10 General purpose  
10  
10  
Heavy pilot duty  
(A 600)  
Switching capacity  
Rated voltage  
AC  
DC  
[A]  
[V]  
[A]  
Heavy pilot duty (A 600)  
max. 600  
A 600  
0.1  
max. 250  
0.1  
max. 600  
max. 600  
Standard pilot  
duty (P 600)  
Switching capacity  
Light pilot duty (Q 600)  
P 600  
Q 600  
Only with CAB6-P2-B11 and CAB6-P3-B11  
Product Selection - Page 4-10  
4-48  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
General  
100-M  
05 … 09  
100-C, 100S-C  
09 … 85  
CAB6  
12  
-85 … 420-EI  
Rated Isolation Voltage U  
i
IEC, AS, BS, SEV, VDE 0660  
per UL, NEMA, CSA, EEMAC  
[V]  
[V]  
500  
600  
690  
600  
1000  
600  
Rated Impulse Voltage Withstand U  
[kV]  
imp  
8
8
12  
Rated Voltage U  
e
4
AC  
DC  
50/60 Hz  
[V]  
[V]  
230, 240, 400, 415, 500  
24, 48, 110, 220, 440  
Class «B» per IEC 85  
115, 230, 400, 500, 690  
24, 48, 110, 220, 440  
Class «F» per IEC 85  
230, 240, 400, 415, 500, 690, 1000  
24, 48, 110, 220, 440  
Class «B» per VDE 0660,  
Table 22  
Insulation Class of the Coil  
Rated coil frequency  
Ambient Temperature  
Storage  
AC 50/60 Hz, DC  
AC 50/60 Hz, DC  
AC 50 Hz, 50/60 Hz, DC  
[°C]  
[°C]  
-55 … +80  
-25 … +60  
-55 …+80  
-25 …+60  
-40 …+80  
-25 …+60  
Operation at rated voltage  
at 70 °C  
15 % current reduction against 60 °C values  
IEC 68-2  
Climatic Withstand  
Max. Altitude of Installation Site  
Protection Class  
IEC 68-2  
IEC 68-2  
[m]  
2000 NN, per IEC 947-4  
2000 NN, per IEC 947-4  
IP2X (in connected state)  
2000 NN, per IEC 947-4  
IP00 IEC 529 / DIN 40 050  
IP10 IEC 529 / DIN 40 050  
IP20 IEC 529 / DIN 40 050  
IP20 IEC 529 / DIN 40 050  
Finger and back-of-hand proof  
per VDE 0106, part 100  
IEC 68-2  
IP2X  
Single contactor cover  
Contactor with frame terminal block  
Auxiliary contact  
Protection against Accidental Contact  
Finger and back-of-hand proof  
per VDE 0106, part 100  
IEC 68-2  
Finger and back-of-hand proof  
per VDE 0106, part 100  
IEC 68-2  
Resistance to Shock  
Resistance to Vibration  
IEC 68-2  
IEC 68-2  
IEC 68-2  
Contactor contacts among each other. Restricted guidance guarantees without  
Positively Guided Contacts per SUVA  
Auxiliary contact block contacts next to  
each other.  
restrictions from contactor to auxiliary  
contact and auxiliary contact to  
contactor.  
But not between contactor and auxiliary  
contact block.  
No restricted guidance 100-FL, 100-FPT  
IEC 60947; EN 60947; UL 508;  
CSA 22.2. No. 14  
Standards  
Approvals  
IEC 60947; EN 60947; UL 508;  
CSA 22.2. No. 14  
IEC 60947; EN 60947; UL 508;  
CSA 22.2. No. 14  
CE, UL Listed, CSA,  
CE, UL Listed, CSA, RINA,  
Bureau Veritas, Maritime Register of  
Shipping, American Bureau of Shipping,  
Germanischer Lloyd, Lloyd’s Register of  
Shipping,  
Germanischer Lloyd, Bureau  
CE,  
Veritas, Lloyd’s Register of  
UL Listed,  
CE, UL Listed, CSA  
Shipping,  
CSA,  
Maritime Register of  
Shipping  
Wershe Veritas in preparation  
Product Selection - Page 4-10  
Rockwell Automation  
4-49  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
Heavy Duty Starting and Regular Short-time Operation  
Bulletin 100-C, CAB6 Contactors  
100  
10  
1
4
10  
100  
1000  
10000  
Starting current / Short-time current [A]  
Electrical Life  
Bulletin 100-M, 100-C, 100S-C, CAB6 Contactors  
L1  
L1  
L1  
L2  
L3  
N
UC  
US  
UC  
US  
PE  
21  
22  
S0  
0
1
2
2
4
3
6
13  
14  
13  
14  
13  
14  
13  
14  
A1  
A2  
K1  
K1  
K1  
S1  
S1  
0/1  
1
A2  
A1  
A2  
A1  
T1 T2 T3  
M1 3 AC  
K1  
H1  
K1  
H1  
N (L2)  
N (L2)  
Impulse contact control  
Continuous contact control  
Utilisation categories  
Switching conditions for verifying electrical life (number of operations under load) per IEC 947-4; -5.  
Making  
Breaking  
Test conditions  
I/I  
U/U  
I /I  
c
U /U  
r e  
cosϕ  
cosϕ  
e
e
e
Resistance furnaces:  
Non-inductive or slightly inductive loads  
AC-1  
AC-2  
AC-3  
AC-4  
AC-15  
1
1
0.95  
1
1
0.95  
Slip-ring motors:  
Starting and reversing  
2.5  
1
0.65  
2.5  
1
0.65  
I 17 A  
I > 17 A  
e
Squirrel-cage motors:  
Starting and stopping of running motors  
6
6
1
1
0.65  
0.35  
1
1
0.17  
0.17  
0.65  
0.35  
e
I 17 A  
Squirrel-cage motors:  
Starting, reversing, stepping  
6
6
1
1
0.65  
0.35  
6
6
1
1
0.65  
0.35  
e
I > 17 A  
e
Solenoids:  
for contactors, valves, and lifting magnets  
10  
1
0.7  
1
1
0.4  
U
I
Recovery voltage  
Making current  
I
U
Breaking current  
Off-load voltage  
r
c
I
U
Rated operating current  
Rated operating voltage  
e
e
The following values are valid for the operating conditions defined in IEC 947-4 and utilisation categories AC-1...AC-4 at 400V, 50/60 Hz.  
Product Selection - Page 4-10  
4-50  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
Electrical Life  
100-M  
Electrical Life; Ue = 400 / 415 VAC  
AC-3 Switching of squirrel-cage motors while starting  
AC-1 Non- or slightly inductive loads, resistance furnaces  
10  
4
1
100-M12  
100-M09  
0.1  
100-M05  
(AC-1)  
0.01  
1
10  
100  
Rated operating current I AC-2 [A]  
e
(Dashed curves - - - - AC-1 only, open)  
100-M  
Electrical Life; Ue = 400 / 415 VAC  
AC-4 Stepping of squirrel-cage motors  
10  
100-M09; 100-M12  
100-M05  
1
0.1  
0.01  
0.1  
1
10  
Rated operating current I [A]  
e
Product Selection - Page 4-10  
Rockwell Automation  
4-51  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
Electrical Life  
100-C  
AC-1 40° C Non- or slightly inductive loads, resistance furnaces; Ue = 230…690 V  
10  
4
1
0.1  
1
10  
Rated operating current I AC-1 [A]  
100  
e
100-C  
AC-2 Stepping of slip-ring motors; Ue = 230…400…460 V  
10  
C12  
C09  
1
0.1  
1
10  
Rated operating current I AC-2 [A]  
100  
e
Product Selection - Page 4-10  
4-52  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
Electrical Life  
100-C  
AC-3 Switching of squirrel-cage motors while starting; Ue = 230…400…460 V  
10  
4
1
0.1  
1
10  
Rated operating current I AC-3 [A]  
100  
e
100-C  
AC-3 Switching of squirrel-cage motors while starting; Ue = 500…575 V  
10  
1
0.1  
1
10  
Rated operating current I AC-3 [A]  
100  
e
Product Selection - Page 4-10  
Rockwell Automation  
4-53  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
Electrical Life  
100-C  
AC-3 Switching of squirrel-cage motors while starting; Ue = 690 V  
10  
4
1
0.1  
1
10  
100  
Rated operating current I AC-3 [A]  
e
100-C  
AC-4 Stepping of squirrel-cage motors; Ue = 230…690 V  
10  
1
0.1  
1
10  
100  
Rated operating current I AC-4 [A]  
e
Product Selection - Page 4-10  
4-54  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
Electrical Life  
100-C  
AC-3 90 % & AC-4 10 % Mixed operation of squirrel-cage motors; Ue = 230…400…460 V  
10  
C09  
4
1
0.1  
1
10  
Rated operating current I AC-3 / AC-4 [A]  
100  
e
CAB6  
AC-3 Switching of squirrel-cage motors while starting  
AC-1 Non- or slightly inductive loads, resistance furnaces; Ue = 400 V  
10  
1
(AC-1)  
0.1  
10  
100  
1000  
Rated operating current I AC-3 [A]  
e
(Dashed curves ------ AC-1 only, open)  
Product Selection - Page 4-10  
Rockwell Automation  
4-55  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
Electrical Life  
CAB6  
AC-4 Stepping of squirrel-cage motors; Ue = 400 V  
10  
4
1
0.1  
0.01  
100  
1
10  
1000  
Rated operating current I AC-4 [A]  
e
CAB6  
AC-3 90 % & AC-4 10 % Mixed operation of squirrel-cage motors; Ue = 400 V  
10  
1
0.1  
10  
100  
Rated operating current I AC-3 / AC-4 [A]  
1000  
e
Product Selection - Page 4-10  
4-56  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
Permissible Switching Rate  
100-C  
AC-1 40° C Non- or slightly inductive loads, resistance furnaces; Ue = 230…690 V  
3000  
2500  
C09/C12/C16/C23  
C30/C37  
C43  
4
2000  
1500  
1000  
C60/C72/C85  
500  
0
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
P/Pn [%]  
100-C  
AC-2 Stepping of slip-ring motors; Ue = 230…460 V  
10000  
1000  
100  
C09/C12/C16  
C23/C30/C37/C43  
C60  
C72  
C85  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
P/Pn [%]  
Product Selection - Page 4-10  
Rockwell Automation  
4-57  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
Permissible Switching Rate  
100-C  
AC-3 Switching of squirrel-cage motors while starting; Ue = 230…460 V  
Relative operating time 40 %, Starting time tA = 0.25 s  
10000  
1000  
100  
4
C09/C12/C16  
C23/C30/C37/C43  
C60/C72/C85  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
P/Pn [%]  
100-C  
AC-4 Stepping of squirrel-cage motors; Ue = 230…460 V  
Starting time tA = 0.25 s  
1000  
C09  
C12  
C16  
100  
C23/C30  
C37/C43/C60  
C72  
C85  
10  
0
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
P/Pn [%]  
Product Selection - Page 4-10  
4-58  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
Permissible Switching Rate  
CAB6  
AC-3 Switching of squirrel-cage motors while starting  
Relative operating time 40 %, Starting time tA = 0.25 s  
10000  
1000  
100  
4
10  
10  
100  
1000  
Rated operating current I [A]  
e
CAB6  
AC-3 Switching of squirrel-cage motors while starting  
Relative operating time 40 %, Starting time tA = 1 s  
10000  
1000  
100  
10  
10  
100  
Rated operating current I [A]  
1000  
e
Product Selection - Page 4-10  
Rockwell Automation  
4-59  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Specifications  
Permissible Switching Rate  
CAB6  
AC-2, AC-4 Stepping of motors  
Starting time tA = 0.25 s  
10000  
4
short time  
CAB6-140(-EI), CAB6-170(-EI)  
CAB6-85, CAB6-105(-EI)  
1000  
100  
10  
10  
100  
1000  
10000  
Starting current I [A]  
A
CAB6  
AC-2, AC-4 Stepping of motors  
Starting time tA = 1 s  
10000  
1000  
100  
CAB6-85, CAB6-105(-EI)  
CAB6-140(-EI), CAB6-170(-EI)  
short time  
10  
10  
100  
1000  
10000  
Starting current I [A]  
A
Product Selection - Page 4-10  
4-60  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Dimensions  
Bulletin 100-M  
Dimensions in millimetres  
Mounting Position  
c2  
c1  
d2  
c
ød  
4
a
a1  
Type  
a
a1  
67  
b
b1  
47  
c
c1  
c2  
ød  
d1  
d2  
100-M  
45  
56  
48  
74  
77  
4
50  
40  
Contactor with …  
[mm]  
Mechanical interlock  
Auxiliary contact block  
Timer  
a+a  
c1  
Mountable on 35 mm DIN Rail EN50 022  
front-mounted  
side-mounted  
side-mounted  
c2  
(Combined DIN/C Rail mounting not possible when  
using mechanical latch or mechanical interlock)  
a1  
Neutral terminal  
Suppressor module  
Label holder  
a+20  
c2  
c..+5  
Bulletin 100-C  
4.6 (3/16)  
ø 4,6 (3/16)  
ø 25 (63/64)  
66  
48  
(2-19/32)  
(1-57/64)  
132  
(5-13/64)  
4
(5/32)  
50  
(1-31/32)  
Prestamping for pilot lamp  
90  
(3-35/64)  
Product Selection - Page 4-10  
Rockwell Automation  
4-61  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Dimensions  
Bulletin 100-C  
Dimensions are shown in millimetres and (inches)  
Mounting Position  
AC Control  
c2  
ø d  
4
DC Control  
c3  
c1  
c
d2  
a
+...  
+...  
+...  
AC Control  
Type  
a
b
c
c1  
c2  
c3  
ød  
d1  
60  
d2  
45  
(1- 25/32)  
81  
(3- 3/16)  
80.5  
(3- 11/64)  
75.5  
(3- 3/32)  
6
(1/4)  
4.5  
(3/16)  
2 pcs each 4.5  
35  
(1- 25/64)  
100-C09 … 100-C23  
100-C30 … 100-C37  
100-C43  
(2 pcs each 3/16) (2- 23/64)  
2 pcs each 4.5 60  
(2 pcs each 3/16) (2- 23/64)  
2 pcs each 4.5 60  
(2 pcs each 3/16) (2- 23/64)  
4 pcs each 5.4 100  
(4 pcs each 7/32) (3- 15/16)  
45  
(1- 25/32)  
81  
(3- 3/16)  
97.5  
(4)  
92.6  
(3- 49/64)  
6.5  
(17/64)  
4.5  
(3/16)  
35  
(1- 25/64)  
54  
(2- 1/8)  
81  
(3- 3/16)  
100.5  
(4- 7/64)  
95.6  
(3- 7/8)  
6.5  
(17/64)  
5
(13/64)  
45  
(1- 25/32)  
72  
(2- 53/64)  
122  
(4- 51/64)  
117  
(4- 49/64)  
111.5  
(4- 35/64)  
8.5  
(21/64)  
5.5  
(7/32)  
55  
(2- 11/64)  
100-C60 … 100-C85  
DC Control  
Type  
a
b
c
c1  
c2  
c3  
ød  
d1  
d2  
45  
(1- 25/32)  
81  
(3- 3/16)  
106.5  
(4- 3/16)  
101.5  
(4)  
6
(1/4)  
4.5  
(3/16)  
2 pcs each 4.5  
60  
35  
(1- 25/64)  
100-C09Z … 100-C16Z  
(2 pcs each 3/16) (2- 23/64)  
2 pcs each 4.5 60  
(2 pcs each 3/16) (2- 23/64)  
2 pcs each 4.5 60  
(2 pcs each 3/16) (2- 23/64)  
2 pcs each 4.5 60  
(2 pcs each 3/16) (2- 23/64)  
4 pcs each 5.4 100  
(4 pcs each 7/32) (3- 15/16)  
45  
(1- 25/32)  
81  
(3- 3/16)  
123.5  
(4- 55/64)  
119  
(4- 43/64)  
6
(1/4)  
4.5  
(3/16)  
35  
(1- 25/64)  
100-C23Z  
45  
(1- 25/32)  
81  
(3- 3/16)  
141.5  
(5- 37/64)  
136.5  
(5- 3/8)  
6.5  
(17/64)  
4.5  
(3/16)  
35  
(1- 25/64)  
100-C30Z … 100-C37Z  
100-C43Z  
54  
(2- 1/8)  
81  
(3- 3/16)  
144.5  
(5- 11/16)  
140  
(5- 33/64)  
6.5  
(17/64)  
5
(13/64)  
45  
(1- 25/32)  
72  
(2- 53/64)  
122  
(4- 51/64)  
117  
(4- 49/64)  
111.5  
(4- 35/64)  
8.5  
(21/64)  
5.5  
(7/32)  
55  
(2- 11/64)  
100-C60Z … 100-C85Z  
Accessories  
AC Control  
[mm] [inches]  
c/c1 + 39 c/c1 + 1- 37/64 c/c1 + 39 c/c1 + 1- 37/64  
DC Control  
Contactor with …  
[mm] [inches]  
Auxiliary contact block, front-mounted  
Auxiliary contact block, side-mounted  
Pneumatic timing module  
2- or 4-pole  
1- or 2-pole  
a + 9  
a + 23/64  
a + 9  
a + 23/64  
c/c1 + 58 c/c1 + 2- 23/64  
Solid-State timing module (100-ETA)  
on coil connection side  
b + 24  
b + 24  
a + 9  
b + 15/16  
b + 15/16  
a + 23/64  
b + 24  
b + 15/16  
Solid-State timing module (100-ETB / 100-ETY) on coil connection side  
Mechanical interlock  
Mechanical latch  
Interface  
side-mounted  
a + 9  
a + 23/64  
c/c1 + 61 c/c1 + 2- 31/64  
on coil connection side  
on coil connection side  
b + 9  
b + 3  
b + 23/64  
b + 1/8  
Suppressor module  
Marking with  
b + 3  
b + 1/8  
sheets of labels  
+ 0  
+ 0  
+ 5.5  
+ 5.5  
+ 0  
+ 0  
+ 7/32  
+ 7/32  
+ 0  
+ 0  
+ 5.5  
+ 5.5  
+ 0  
+ 0  
+ 7/32  
+ 7/32  
marking sheets with cover  
label holder for System V4/V5  
label holder for System Bul. 1492W  
Mountable on 35 mm DIN Rail EN 50 022  
Product Selection - Page 4-10  
4-62  
Rockwell Automation  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Dimensions  
Bulletin 100S-C  
Dimensions are shown in millimetres and (inches)  
Mounting Position  
AC Control  
c2  
ø d  
4
DC Control  
c3  
d2  
c1  
c
+...  
a
+...  
AC Control  
Type  
a
b
c
c1  
c2  
c3  
ød  
d1  
d2  
45  
(1- 25/32)  
81  
(3- 3/16)  
119.5  
(4-3/4)  
114.5  
(4-43/64)  
6
(1/4)  
4.5  
(3/16)  
2 pcs each 4.5  
60  
35  
(1- 25/64)  
100S-C09…100S-C23  
100S-C30…100S-C37  
100S-C43  
(2 pcs each 3/16) (2- 23/64)  
2 pcs each 4.5 60  
(2 pcs each 3/16) (2- 23/64)  
2 pcs each 4.5 60  
(2 pcs each 3/16) (2- 23/64)  
4 pcs each 5.4 100  
(4 pcs each 7/32) (3- 15/16)  
45  
(1- 25/32)  
81  
(3- 3/16)  
136.5  
(5-37/64)  
131.6  
(5-11/32)  
6.5  
(17/64)  
4.5  
(3/16)  
35  
(1- 25/64)  
54  
(2- 1/8)  
81  
(3- 3/16)  
139.5  
(5-11/16)  
134.6  
(5-29/64)  
6.5  
(17/64)  
5
(13/64)  
45  
(1- 25/32)  
72  
(2- 53/64)  
122  
(4- 51/64)  
156  
(6-11/32)  
150.5  
(6-1/8)  
8.5  
(21/64)  
5.5  
(7/32)  
55  
(2- 11/64)  
100S-C60…100S-C85  
DC Control  
Type  
a
b
c
c1  
c2  
c3  
ød  
d1  
d2  
45  
(1- 25/32)  
81  
(3- 3/16)  
145.5  
(5-49/64)  
140.5  
(5-37/64)  
6
(1/4)  
4.5  
(3/16)  
2 pcs each 4.5  
60  
35  
(1- 25/64)  
100S-C09Z…100S-C16Z  
(2 pcs each 3/16) (2- 23/64)  
2 pcs each 4.5 60  
(2 pcs each 3/16) (2- 23/64)  
2 pcs each 4.5 60  
(2 pcs each 3/16) (2- 23/64)  
2 pcs each 4.5 60  
(2 pcs each 3/16) (2- 23/64)  
4 pcs each 5.4 100  
(4 pcs each 7/32) (3- 15/16)  
45  
(1- 25/32)  
81  
(3- 3/16)  
162.5  
(6-7/16)  
158  
(6-1/4)  
6
(1/4)  
4.5  
(3/16)  
35  
(1- 25/64)  
100S-C23Z  
45  
(1- 25/32)  
81  
(3- 3/16)  
180.5  
(7-5/32)  
175.5  
(6-61/64)  
6.5  
(17/64)  
4.5  
(3/16)  
35  
(1- 25/64)  
100S-C30Z…100S-C37Z  
100S-C43Z  
54  
(2- 1/8)  
81  
(3- 3/16)  
183.5  
(7-17/64)  
179  
(7-3/32)  
6.5  
(17/64)  
5
(13/64)  
45  
(1- 25/32)  
72  
(2- 53/64)  
122  
(4- 51/64)  
156  
(6-11/32)  
150.5  
(6-1/8)  
8.5  
(21/64)  
5.5  
(7/32)  
55  
(2- 11/64)  
100S-C60D…100S-C85D  
Accessories  
AC C control  
[mm] [inches]  
DC Control  
Contactor with …  
[mm]  
[inches]  
Auxiliary contact block, side-mounted  
Solid-state timing module (100-ETA)  
1- or 2-pole  
a + 9  
b + 24  
b + 24  
a + 9  
a + 23/64  
b + 15/16  
b + 15/16  
a + 23/64  
b + 23/64  
b + 1/8  
a + 9  
b + 24  
a + 23/64  
b + 15/16  
on coil connection side  
Solid-state timing module (100-ETB / 100-ETY) on coil connection side  
Mechanical interlock  
Interface  
side-mounted  
a + 9  
a + 23/64  
on coil connection side  
on coil connection side  
b + 9  
Suppressor Module  
Marking with  
b + 3  
b + 3  
b + 1/8  
sheets of labels  
+ 0  
+ 0  
+ 5.5  
+ 5.5  
+ 0  
+ 0  
+ 7/32  
+ 7/32  
+ 0  
+ 0  
+ 5.5  
+ 5.5  
+ 0  
+ 0  
+ 7/32  
+ 7/32  
marking sheets with cover  
label holder for System V4/V5  
label holder for System Bul. 1492W  
Mountable on 35 mm DIN Rail EN 50 022  
Product Selection - Page 4-10  
Rockwell Automation  
4-63  
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6  
Contactors  
Dimensions  
Bulletin CAB6  
Dimensions in millimetres  
Mounting Position  
e2  
c1  
e1  
øe  
25˚  
˚
115  
115  
˚
˚
115  
4
ød  
d2  
a
c
Type  
CAB6-85, CAB6-105  
a
b
c
c1  
ød  
5.2  
5.2  
6.5  
d1  
d2  
øe  
M6  
e1  
16  
20  
25  
e2  
38.5  
39  
e3  
e4  
8
120  
120  
155  
170  
170  
205  
156  
156  
180  
110.5  
110.5  
110.5  
145  
145  
180  
100  
100  
130  
147  
160  
193  
CAB6-105-EI…CAB6-170-EI,  
CAB6-140  
M8  
10  
CAB6-210-EI …CAB6-420-EI  
M10  
48  
12.5  
Contactor with …  
[mm]  
Auxiliary contact block  
P1 + P2  
a
+ P3, or + P4  
a + each 13.5  
Mechanical interlock  
Terminal block  
a + a  
HB 1  
HB 2  
HB 3  
b + each 7  
b + each 7  
b + each 8.5  
No change of base dimensions with 1 or 2 auxiliary contact  
blocks (P1, P2).  
With 3 or 4 auxiliary contact blocks (P3, P4), add 13.5 mm each.  
Suppressor module  
Label holder  
HA 1  
HA 2  
HA 3  
b + each 20…40  
b + each 15…40  
b + each 11…50  
c.. + 5  
Bulletin CAB6 Mounting Plates  
M6  
Type  
a
b
c
6
6
6
6
6
6
ød  
6.5  
6.5  
6.5  
6.5  
6.5  
6.5  
d1  
d2  
[kg]  
1
CAB6-105-PS  
CAB6-105-PU  
CAB6-105-PY  
CAB6-250-PS  
CAB6-250-PU  
CAB6-250-PY  
150 340  
270 340  
390 340  
188 380  
344 380  
499 380  
315 135  
315 255  
315 275  
315 173  
1.8  
2.5  
1.4  
315 328.5 2.6  
315 484 3.75  
ød  
C
d2  
a
Product Selection - Page 4-10  
4-64  
Rockwell Automation  
Bulletin 100-G  
Contactors  
4
Bulletin 100-G  
Contactors  
315 … 710 kW  
(550 … 1200 A)  
Table of Contents  
Description  
Page Description  
Page  
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2  
Specifications  
Performance Data / Characteristics . . . . . . . . . . . . . . . . . . . . 4-69  
Weight. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-72  
Standards and Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-74  
Electrical Life. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-75  
Permissible Switching Rate. . . . . . . . . . . . . . . . . . . . . . . . . . . 4-76  
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-78  
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-66  
Accessories  
Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-67  
Renewal Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-68  
Rockwell Automation  
4-65  
Bulletin 100-G  
Contactors  
Product Selection  
4
AC, DC Control  
EN Basic Number  
AC-1  
[A]  
Switching of 3-phase Motors AC-2, AC-3  
[kW] ➊  
[A]  
Cat. No.  
PQ  
40 °C  
230 V  
400 V  
500 V  
690 V  
230 V  
400 V  
500 V  
690 V  
N.O.  
N.C.  
760  
160  
220  
280  
335  
400  
315  
400  
500  
600  
710  
400  
500  
630  
750  
850  
500  
630  
550  
700  
550  
700  
550  
700  
500  
630  
2
2
2
2
2
2
2
100-G550 22  
100-G700 22  
100-G860 22  
100-G1000 12  
100-G1200 12  
1000  
1100  
1200  
1350  
710  
860  
860  
860  
700  
2
1
900  
1000  
1200  
1000  
1200  
1000  
1200  
860  
2 ➊  
2 ➊  
1000  
1000  
1 auxiliary contact (1 N.O. contact used in control circuit)  
Voltage Suffix Code  
For Use with  
100-110 V 110-120 V 200-220 V 220-240 V 345-380 V 380-415 V 400-440 V 440-480 V  
50/60 Hz  
DC  
KD  
KF  
KN  
KB  
100-G550…100-G860  
KD  
KF  
KN  
KB  
For Use with  
110-115 V  
110 V  
200-230 V  
220 V  
240 V  
380-400 V  
440 V  
50/60 Hz  
DC  
KD  
KF  
KA  
KN  
KB  
100-G1000…100-G1200  
ZD  
ZA  
Price Adder for:  
Type  
Available Control Voltages  
No Surcharge  
100-G550…100-G860  
100-G1000, 100-G1200  
24…600 V 50/60 Hz, 24…440 VDC  
48…600 V 50/60 Hz, 48…440 VDC  
Special control voltages  
> 25 pieces  
Power ratings: Preferred values according to IEC 60072-1  
PQ = Package Quantity  
Accessories - Page 4-67  
Specifications - Page 4-69  
Dimensions - Page 4-78  
4-66  
Rockwell Automation  
Bulletin 100-G  
Contactors  
Accessories  
Modules  
Description  
Auxiliary Contact Blocks  
For Use with  
Cat. No.  
PQ  
Up to 2 auxiliary contact blocks per contactor.  
With the EF22 auxiliary switch block, the switching point of  
the normally closed contact in relation to the main contacts  
can be altered. See instructions included with the auxiliary  
contact block.  
mounted between  
T1 and T2  
mounted between  
T2 and T3  
1
13  
43  
21 31  
53  
83  
61 71  
100-G550…100-G860  
100-G1000, 100-G1200  
100-EF22  
4
22 32  
14  
44  
62 72  
54  
84  
Up to 4 auxiliary contact blocks per contactor.  
1 make + 1 break  
1 make + 1 late break  
100-EB11  
100-EB11DC  
Fourth Main Contact Pole  
Left- or right-side mountable  
100-G550  
100-G700, 100-G860  
100-NP500-5  
100-NP500-6  
I
I
AC-1 500 A  
AC-1 900 A  
th  
th  
1
1
100-NP1000-6  
100-NP1000-7  
100-G700, 100-G860  
100-G1000, 100-G1200  
Mechanical Latch  
Mechanical life: 0.5 million operations  
100-FLAM5  
100-FLAM6  
Direct and impulse contact control 100-G550  
Direct and impulse contact control 100-G700, 100-G860  
100-G550 / 100-G550  
100-G550 / 100-G700,  
100-G860  
100-G700, 100-G860 /  
100-G700, 100-G860  
100-G700, 100-G860 /  
100-G1000, 100-G1200  
100-MC00-5H  
100-MC00-56H  
Mechanical Interlock  
The interlocks are delivered factory-mounted  
100-MC00-6H  
100-MC00-67H  
1
for 2 contactors mounted side by side  
100-G1000, 100-G1200 /  
100-G1000, 100-G1200  
100-MC00-7H  
100-G550 / 100-G550  
100-G550 / 100-G700,  
100-G860  
100-MC00-5V  
100-MC00-56V  
100-G700, 100-G860 /  
100-G700, 100-G860  
100-G700, 100-G860 /  
100-G1000, 100-G1200  
100-MC00-6V  
100-MC00-67V  
for 2 contactors stacked vertically  
1
100-G1000, 100-G1200 / 100-  
G1000, 100-G1200  
100-MC00-7V  
Voltage Suffix Code  
For Use with  
110-120 V  
220-240 V  
380-415 V  
KN  
440-480 V  
KB  
100-G550…100-G1200  
50/60 Hz  
KD  
KF  
Price Adder for:  
Type  
Available Control Voltages  
No Surcharge  
> 25 pieces  
Special control voltages  
100-FLAM  
12…550 V 50/60 Hz upon request  
PQ = Package Quantity  
Product Selection - Page 4-66  
Rockwell Automation  
4-67  
Bulletin 100-G  
Contactors  
Accessories  
Renewal Parts  
Description  
For Use with  
Cat. No.  
PQ  
100-G550  
100-AC550  
Arc Chambers for Contactors  
For 3 poles  
1
100-G700, 100-G860  
100-G1000  
100-AC860  
100-AC1000  
4
For 1 pole  
1
1
100-G1200  
100-AC1200  
100-G550  
100-G700  
100-G860  
100-G1000  
100-G1200  
100-CP550  
100-CP700  
100-CP860  
100-CP1000  
100-CP1200  
Main Contacts for Contactors  
Set for 1 pole  
Coils and Supply Modules for Contactors  
Only available as renewal part  
100-G550  
100-G700…100-G860  
100-G1000…100-G1200  
Coils ➊  
AC/DC control  
see Table  
below  
1
Supply Module  
AC/DC control  
100-G550  
100-G700…100-G860  
100-G1000…100-G1200  
see Table  
below  
Voltage Suffix Codes  
100-G  
AC  
Standard  
Control  
100-G700…  
100-G860  
AC  
Standard  
Control  
Voltages  
100-G1000… 100-  
G1200  
100-G550  
Coil  
DC  
AC /  
DC  
Coil  
Code  
PQ  
PQ  
Standard  
Control  
Voltages  
AC / DC  
Coil  
Code  
Coil  
Coil  
Supply  
module  
Cat. No.  
TXS734  
TXS747  
TXS779  
TXS780  
Supply  
module  
Cat. No.  
TYS734  
TYS747  
TYS779  
TYS780  
Supply  
module  
Cat. No.  
TZS734  
TZS747  
TZS779  
TZS780  
Voltages  
50/60 Hz  
50/60 Hz  
110…115 V  
220…230 V  
380…400 V  
440 V  
Cat. No.  
TX734  
TX747  
TX779  
TX780  
Cat. No.  
TY734  
TY747  
TY779  
TY780  
Cat. No.  
TZ734  
TZ747  
TZ779  
TZ780  
110…120 V  
220…240 V  
380…415 V  
440…480 V  
100…110 V  
200…220 V  
345…380 V  
400…440 V  
KD  
KF  
KN  
KB  
KD  
KF  
KN  
KB  
1
1
Coils sold in pairs  
Price Adder for:  
Type  
Available Control Voltages  
No Surcharge  
100-G550…100-G860  
100-G1000, 100-G1200  
24…600 V 50/60 Hz, 24…440 VDC  
48…600 V 50/60 Hz, 48…440 VDC  
Special control voltages  
>25 pieces  
PQ = Package Quantity  
Product Selection - Page 4-66  
4-68  
Rockwell Automation  
Bulletin 100-G  
Contactors  
Specifications  
IEC Performance Data  
100-G550  
100-G700  
100-G860  
100-G1000  
100-G1200  
AC-1, Three-phase Switching  
Ambient temperature 40 °C  
I
690 V  
[A]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
760  
303  
316  
527  
546  
658  
908  
1 316  
1 000  
398  
1 100  
438  
1 200  
478  
1 350  
538  
e
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
1 000 V  
416  
457  
499  
561  
693  
762  
831  
935  
719  
791  
863  
970  
866  
953  
1 039  
1 434  
1 169  
1 613  
4
1 195  
1 732  
1 315  
1 905  
Ambient temperature 60 °C  
I
690 V  
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
1 000 V  
[A]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
605  
241  
251  
419  
435  
524  
723  
1 048  
800  
319  
333  
554  
575  
693  
956  
1 386  
870  
347  
960  
382  
399  
665  
690  
831  
1 147  
1 085  
432  
451  
752  
780  
940  
1 297  
e
362  
603  
625  
753  
1 040  
1 507  
Constant Current - UL/CSA  
General Purpose Rating 40 °C  
Switching of 3-phase Motors  
[A]  
520  
700  
810  
1 215  
AC-2, AC-3, AC-4  
230/240 V  
400/415 V  
500 V  
[A]  
[A]  
550  
550  
550  
500  
160  
185  
315  
315  
400  
500  
700  
700  
700  
630  
220  
220  
400  
425  
500  
630  
860  
860  
860  
700  
280  
300  
500  
530  
630  
710  
1 000  
1 000  
1 000  
860  
1 200  
1 200  
1 200  
1 000  
400  
[A]  
690 V  
[A]  
230 V ➊  
240 V ➊  
400 V ➊  
415 V ➊  
500 V ➊  
690 V ➊  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
335  
335  
400  
600  
710  
630  
750  
750  
850  
900  
1 000  
AC-4 at 200 000 operations  
230/240 V  
400/415 V  
230 V  
[A]  
[A]  
140  
140  
45  
180  
180  
57  
210  
210  
67  
260  
260  
83  
300  
300  
97  
[kW]  
[kW]  
[kW]  
[kW]  
240 V  
47  
60  
70  
87  
101  
170  
176  
400 V  
78  
101  
105  
118  
122  
146  
151  
415 V  
81  
AC-4, Squirrel-cage motors with reversing  
and jogging at 20 000 (25 000), operations  
230/240 V  
[A]  
[A]  
360  
350  
116  
111  
198  
206  
430  
420  
139  
151  
238  
247  
520  
520  
170  
177  
295  
300  
(630)  
(630)  
(205)  
(214)  
(357)  
(359)  
(700)  
(700)  
(228)  
(245)  
(414)  
(424)  
400/415 V ➊  
230 V  
[kW]  
[kW]  
[kW]  
[kW]  
240 V  
400 V  
415 V  
Switching of 3-phase Motors - UL/CSA  
60 Hz/60 °C  
200 V  
230 V  
460 V  
575 V  
200 V  
230 V  
460 V  
575 V  
[A]  
[A]  
414  
360  
414  
336  
150  
150  
350  
350  
552  
602  
590  
472  
200  
250  
500  
500  
692  
722  
708  
576  
250  
300  
600  
600  
1 185  
1 130  
1 062  
864  
[A]  
[A]  
[HP]  
[HP]  
[HP]  
[HP]  
450  
450  
900  
900  
At rated voltage 415V and rated current: Life span -25 %  
Power ratings: Preferred values according to IEC 60072-1  
Product Selection - Page 4-66  
Rockwell Automation  
4-69  
Bulletin 100-G  
Contactors  
Specifications  
IEC Performance Data  
100-G550  
100-G700  
100-G860  
100-G1000  
100-G1200  
Rated making capacity  
AC-4  
I
415 V  
500 V  
[A]  
[A]  
[A]  
5 500  
5 500  
5 000  
7 000  
7 000  
6 300  
8 600  
8 600  
7 000  
10 000  
10 000  
8 600  
12 000  
12 000  
10 300  
e
690 V  
Rated breaking capacity  
AC-4  
I
240 V  
400 V  
415 V  
500 V  
690 V  
[A]  
[A]  
[A]  
[A]  
[A]  
5 500  
4 500  
4 500  
4 500  
4 500  
7 000  
5 600  
5 600  
5 600  
5 600  
8 000  
6 900  
6 900  
6 900  
6 000  
8 000  
8 000  
8 000  
8 000  
6 900  
9 600  
9 600  
9 600  
9 600  
8 000  
e
4
Star-Delta Starting  
50 Hz  
500 V  
690 V  
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
1 000 V  
[A]  
[A]  
953  
831  
310  
324  
540  
561  
705  
883  
615  
1 212  
1 091  
395  
1 490  
1 195  
485  
1 732  
1 490  
565  
2 078  
1 732  
677  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
[kW]  
412  
507  
589  
707  
717  
882  
1 025  
1 088  
1 309  
1 554  
1 250  
1 278  
1 538  
2 078  
745  
915  
897  
1 102  
1 247  
970  
1 138  
866  
Star-Delta Starting  
60 Hz  
230 V  
460 V  
575 V  
[A]  
[A]  
[A]  
250  
600  
600  
450  
800  
800  
500  
650  
750  
1 000  
1 000  
1 300  
1 500  
1 500  
1 500  
Short-circuit Protection of Contactors  
without Overload Relay  
Fuse gG (aM) Type «1» coordination  
(630)  
(630)  
800  
800  
1 000  
1 000  
1 000  
1 000  
1 250  
1 000  
per IEC 947-4-1  
500 V  
690 V  
[A]  
[A]  
Switching of Three-phase Capacitor Motors  
Inductivity of dispatching between parallel  
switched capacitors: min. 6 µH  
Single capacitors 40 °C  
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
[kVar]  
180  
200  
320  
350  
450  
580  
150  
170  
280  
300  
360  
500  
180  
200  
320  
350  
450  
580  
150  
170  
280  
300  
360  
500  
220  
250  
400  
430  
520  
700  
180  
200  
330  
360  
420  
580  
220  
250  
400  
430  
520  
700  
180  
200  
330  
360  
420  
580  
250  
300  
450  
500  
600  
800  
220  
260  
400  
450  
540  
720  
250  
300  
450  
500  
600  
800  
220  
260  
400  
450  
540  
720  
290  
325  
500  
550  
660  
875  
275  
300  
460  
500  
600  
800  
290  
325  
500  
550  
660  
875  
275  
300  
460  
500  
600  
800  
330  
360  
575  
630  
750  
1 000  
325  
350  
550  
600  
720  
950  
330  
360  
575  
630  
750  
1 000  
325  
350  
550  
600  
720  
950  
55 °C  
Control capacitors 40 °C  
55 °C  
Product Selection - Page 4-66  
4-70  
Rockwell Automation  
Bulletin 100-G  
Contactors  
Specifications  
IEC Performance Data  
100-G550  
100-G700  
100-G860  
100-G1000  
100-G1200  
Switching of DC Loads  
Switching of non- or slightly inductive loads,  
resistance furnaces DC-1 at 60 °C  
1-pole  
24/48 V  
24/48 V  
24/48 V  
110 V  
[A]  
[A]  
[A]  
[A]  
[A]  
645  
645  
645  
480  
315  
760  
760  
760  
560  
400  
930  
930  
930  
630  
450  
1 020  
1 020  
1 020  
800  
1 150  
1 150  
1 150  
900  
2 Poles in series  
3 Poles in series  
220 V  
500  
600  
4
Shunt Motors  
Starting, regenartive brake, reverse,  
Jogging DC-3, 60 °C  
3 Pole in Serie  
24/48 V  
[A]  
[A]  
605  
605  
800  
800  
870  
870  
960  
960  
1 085  
1 085  
Series-characteristic Motors  
Starting, regenartive brake, reverse,  
Jogging DC-5, 60 °C  
3 Pole in Serie  
Switching of Lamps  
24/48 V  
Electric discharge lamps AC-5a  
Single compensated:  
open  
close  
[A]  
[A]  
450  
360  
570  
460  
700  
550  
850  
660  
1 000  
800  
Incandescent lamps AC-5b  
Electrical Lifespan  
~ 100 000 operations  
[A]  
315  
440  
500  
560  
630  
Switching of Transformers AC-6a  
Switch-on peak load  
= n  
Rated transformer current  
Rated transformer current  
[A]  
[kVA]  
[kVA]  
[kVA]  
[kVA]  
[kVA]]  
259  
248  
248  
225  
389  
517  
330  
315  
315  
284  
495  
660  
405  
390  
390  
315  
608  
810  
470  
450  
450  
450  
700  
945  
570  
540  
n = 30  
400 VAC  
500 VAC  
690 VAC  
540  
540  
n = 20  
n = 15  
850  
1 130  
Short-time Withstand I  
60 °C  
1 s  
CW,  
[A]  
[A]  
5 500  
5 500  
4 400  
3 800  
2 300  
1 300  
850  
7 000  
7 000  
5 600  
5 000  
2 800  
1 800  
1 150  
60  
8 000  
8 000  
6 900  
6 000  
3 400  
2 000  
1 350  
60  
10 000  
10 000  
8 000  
7 400  
4 000  
2 300  
1 600  
60  
12 000  
12 000  
9 600  
8 500  
4 800  
2 700  
1 900  
60  
4 s  
10 s  
15 s  
60 s  
240 s  
900 s  
[A]  
[A]  
[A]  
[A]  
[A]  
Minimum Cooling Time at Zero Current  
Resistance and Power Dissipation  
Main current circuit resistance  
[Min.]  
60  
[m]  
[W]  
0.11  
99  
0.1  
0.08  
177  
0.06  
300  
0.05  
318  
Power dissipation of all at I AC-3  
147  
e
Total power dissipation  
at I AC-3  
e
ACcontrol  
DC control  
[W]  
[W]  
110  
109  
172  
169  
202  
199  
370  
360  
388  
378  
Product Selection - Page 4-66  
Rockwell Automation  
4-71  
Bulletin 100-G  
Contactors  
Specifications  
IEC Performance Data  
100-G550  
100-G700  
100-G860  
100-G1000  
100-G1200  
Lifespan  
mechanical  
AC control  
DC control  
AC-3 (400 V)  
AC control  
DC control  
[Mio. operations]  
[Mio. operations]  
[Mio. operations]  
[kg]  
5
5
1
1
0.6  
Weight  
13.8  
26.4  
28.4  
50.3  
53.4  
[kg]  
Connections Main Contacts  
Terminal type  
4
2
[mm ]  
6x40  
5x50  
8x50  
10x50  
10x60  
Connections Contactor  
Hole diameter  
[mm]  
(1) x ø13  
(1) x ø15  
(2) x ø17  
50  
25  
60  
25  
60  
25  
60  
25  
60  
25  
b max.  
[mm]  
[mm]  
[mm]  
[mm]  
c
c
c max.  
s max.  
Ø max.  
s
s
b
b
2 x 5  
12.5  
2 x 5  
13  
2 x 6  
15  
2 x 6  
2 x 13  
2 x 8  
2 x 13  
c
s
b
Recommended torque  
With terminal lug  
Nm]  
50  
60  
75  
90  
90  
100-LG5  
100-LG6  
100-LG6  
100-LG7  
100-LG7  
2
[mm ]  
(2) x 35…300  
(3) x 35…300  
(3) x 35…300  
(4) x 35…300  
(4) x 35…300  
Wire cross-section acc. to EC 60947-1  
Wire cross-section acc. to UL/CSA  
Auxiliary contact  
[AWG] (2) x No. 2…600 MCM (3) x No. 2…600 MCM (3) x No. 2…600 MCM (4) x No. 2…600 MCM (4) x No. 2…600 MCM  
2
[mm ]  
(2) x 4  
(2) x 4  
2
[mm ]  
Coils  
Product Selection - Page 4-66  
4-72  
Rockwell Automation  
Bulletin 100-G  
Contactors  
Specifications  
Control Circuits  
100-G550  
100-G700  
100-G860  
100-G1000  
100-G1200  
Operating Limits  
AC- 50 Hz  
pick-up  
dropout  
pick-up  
dropout  
pick-up  
dropout  
[x U ]  
s
0.85…1.1  
0.85…1.1  
0.85…1.1  
[x U ]  
s
0.2…0.5  
0.2…0.5  
0.2…0.5  
0.15…0.5  
0.15…0.5  
0.15…0.5  
0.3…0.6  
AC- 60 Hz  
DC control  
[x U ]  
s
[x U ]  
s
0.3…0.6  
0.3…0.6  
[x U ]  
s
[x U ]  
s
Pick-up and Holding Power  
4
AC- 50 Hz  
pick-up  
holding  
pick-up  
holding  
pick-up  
holding  
[VA]  
[VA/W]  
[VA/W]  
[VA/W]  
[W]  
800…950  
9…11  
1 350…1600  
21…25  
2400  
70  
AC- 60 Hz  
800…950  
9…11  
1 350…1 600  
21…25  
2400  
70  
DC control  
700…850  
8…10  
1 300…1 550  
18…22  
2100  
60  
[W]  
Switching Delay  
AC  
closing delay  
opening delay  
closing delay  
opening delay  
[ms]  
[ms]  
[ms]  
[ms]  
50…100  
50…100  
25…50  
50…100  
25…50  
20…50 / 150…200 / 500…1 000 ➊  
50…100  
DC  
20…50 / 150…200 / 500…1 000 ➊  
accelerated  
delayed  
Product Selection - Page 4-66  
Rockwell Automation  
4-73  
Bulletin 100-G  
Contactors  
Specifications  
Auxiliary Contact Blocks  
100-G550  
100-G700  
100-G860  
100-G1000  
100-G1200  
Switching of AC Loads  
AC-1  
I
at 40 °C  
at 60 °C  
[A]  
[A]  
16  
12  
16  
12  
th  
AC-15 at rated voltage of  
120 V  
230 V  
240 V  
400 V  
415 V  
500 V  
690 V  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
[A]  
6
3
6
3
3
3
2
2
4
2
2
1.5  
1
1.5  
1
Switching of DC Loads  
DC-13 Switching of electromagnets at  
24 VDC  
[A]  
[A]  
[A]  
[A]  
6
3
6
3
48 VDC  
110 VDC  
1
1
220 VDC  
0.5  
0.5  
Fuse  
Short-circuit protection with no welding of contacts  
according to IEC 947-5  
Fuse gG  
[A]  
10  
16  
General  
100-G550  
100-G700  
100-G860  
100-G1000  
100-G1200  
Rated Isolation Voltage U  
i
IEC, AS, BS, SEV, VDE 0660  
UL/CSA  
[V]  
[V]  
1 000  
600  
690  
600  
Testing Voltage  
1 minute according to IEC 947-4  
[V]  
3 500  
2 500  
Rated Voltage U  
AC 50/60 Hz  
DC  
e
[V]  
[V]  
230, 240, 400, 415, 500, 690  
230, 240, 400, 415, 500, 690  
24, 48, 110, 220, 440  
Insulation Class of the Coil  
Rated Coil Frequency  
Ambient Temperature  
Storage  
Class «B» according to VDE 0660, table 22  
AC 50/60 Hz, DC  
[°C]  
[°C]  
-40 …+80  
-25 …+60  
Operation at rated current  
Climatic Withstand  
Site Altitude  
Damp alternating conditions cyclical, according to DIN 50 016 and 40 046, Part 38, IEC 68  
2000 NN, according to IEC 947-1  
[m]  
Protection Class  
Shock Protection  
Certifications  
IP00 IEC 529 / DIN 40 050  
Finger- and back of hand proof according to VDE 0106, Part 100  
IEC 947, CEI 17-2, 17-3; UTE NF C 63-110; BS 5424; VDE 0660-1; NEMA; ICS  
CE, UL Listed,  
Approvals  
CE, UL Listed, Lloyd’s Register of Shipping  
CE, Lloyd’s Register of Shipping  
Lloyd’s Register of Shipping  
Product Selection - Page 4-66  
4-74  
Rockwell Automation  
Bulletin 100-G  
Contactors  
Specifications  
Electrical Life  
100-G  
AC-3 Switching of running three-phase motors  
AC-1 Non or slightly inductive loads, resistance furnaces  
10  
4
1
(AC-1)  
0.1  
100  
1000  
10000  
Rated operating current I AC-1 / AC-3 [A]  
e
(Dashed curves - - - for AC-1 only, open)  
1
100-G  
AC-4 Stepping of squirrel-cage motors  
10  
1
0.1  
0.01  
0.001  
10  
100  
1000  
10000  
Rated operating current I AC-4 [A]  
e
Product Selection - Page 4-66  
Rockwell Automation  
4-75  
Bulletin 100-G  
Contactors  
Specifications  
Electrical Life  
100-G  
AC-3 90 % Switching of running motor  
AC-4 Stepping  
10  
4
1
0.1  
0.01  
100  
1000  
10000  
Rated operating current I AC-3 / AC-4 [A]  
e
Permissible Switching Rate  
100-G  
Switching of running squirrel-cage motors (AC-3)  
Relative running time 40 %, starting time tA = 0.25 s  
1000  
100  
10  
100-G-700  
100-G-860  
100-G-550  
100-G-1000, 100G -1200  
100-G-1000 short time  
100  
1000  
Rated operating current I [A]  
10000  
e
Product Selection - Page 4-66  
4-76  
Rockwell Automation  
Bulletin 100-G  
Contactors  
Specifications  
Permissible Switching Rate  
100-G  
Switching of running squirrel-cage motors (AC-3)  
Relative running time 40 %, starting time tA = 1 s  
1000  
100  
10  
4
100-G-1000 short time  
100  
1000  
Rated operating current I [A]  
10000  
e
100-G  
Switching of starting motors (AC-2 and AC-4)  
Starting time tED = 1 s (< tA)  
1000  
100  
10  
100-G-1000  
short time  
100-G-860  
short time  
100  
1000  
Starting current I [A]  
10000  
e
Product Selection - Page 4-66  
Rockwell Automation  
4-77  
Bulletin 100-G  
Contactors  
Dimensions  
100-G  
Dimensions [millimetres]  
Mounting Position  
c1  
e2  
e1  
øe  
ød  
4
d2  
a
c
Type  
100-G550  
a
b
b1  
c
c1  
ød  
d1  
d2  
øe  
e1  
e2  
e3  
220  
280  
280  
334  
334  
258  
307  
361  
490  
490  
228  
277  
325  
434  
434  
225  
291  
291  
345  
345  
164  
203  
203  
231  
231  
9
220  
280  
280  
380  
380  
110  
175  
175  
120  
120  
12.5  
13  
40  
50  
50  
50  
60  
79  
40  
40  
100-G700  
100-G860  
100-G1000  
100-G1200  
11  
11  
13  
13  
101  
101  
100  
100  
15  
2x13  
2x13  
Contactors with:  
100-G  
[mm]  
Auxiliary contact block  
mechanical interlock  
a
side-by-side  
100-G550/100-G550  
100-G700, G860/100-G700, G860  
a+42+a  
a+32+a  
100-G1000, G1200/100-G1000, G1200  
100-G550/100-G700, G860  
100-G700, G860/100-G1000, G1200  
100-G550/100-G550  
a+46+a  
a+37+a  
a+73+a  
stacked vertically  
b+56 + b  
b+100…200+b  
b+230…280+b  
b+100…200+b  
b+230…280+b  
a+74  
100-G700, G860/100-G700, G860  
100-G1000, G1200/100-G000, G1200  
100-G550/100-G700, G860  
100-G700, G860/100-G1000, G1200  
100-G550  
th  
4
main pole  
100-G700, G860  
a+68  
100-G1000, G1200  
a+76  
mechanical latch  
100-G550  
b+59  
100-G700  
b+64  
100-G860  
b+37  
100-G1000, G1200  
a+30  
Insulation partition plate 100-G1200 (UL regulation)  
Product Selection - Page 4-66  
4-78  
Rockwell Automation  

相关型号:

195.8-01M-1

Analog Circuit
COOPER

195.8-01M-2

Analog Circuit
COOPER

195.8-01P-1

Analog Circuit
COOPER

195.8-01P-2

Analog Circuit
COOPER

195.8-05M

Analog Circuit
COOPER

195.8-05M-1

Analog Circuit
COOPER

195.8-05P-1

Analog Circuit
COOPER

195.8-05P-2

Analog Circuit
COOPER

1950049

Modular Terminal Block, ROHS COMPLIANT
PHOENIX

1950094

TERM BLOCK PLUG 2POS STR 5.08MM
PHOENIX

1950100002

Electric Fuse,
LITTELFUSE

1950100043

Electric Fuse,
LITTELFUSE