154N-005G-LT [ETC]

Signal Conditioner ; 信号调理\n
154N-005G-LT
型号: 154N-005G-LT
厂家: ETC    ETC
描述:

Signal Conditioner
信号调理\n

文件: 总2页 (文件大小:123K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Model 154N UltraStable  
Medical Instruments  
Process Control  
Waste Water Management  
Refrigeration/Compressors  
Pressure Transmitters  
Level Systems  
316 SS Pressure Sensor  
0-100 mV Output  
Gage, Sealed Gage and Absolute  
Temperature Compensated  
DESCRIPTION  
The Model 154N is a media compatible, compensated,  
piezoresistive silicon pressure sensor packaged in a 316 stainless  
steel housing. The sensing package utilizes silicone oil to  
transfer pressure from the 316 stainless steel diaphragm to the  
sensing element.  
The Model 154N is designed for low pressure applications.  
A ceramic substrate is attached to the package that contains  
laser-trimmed resistors for temperature compensation and offset  
correction. An additional laser-trimmed resistor is included  
which can be used to adjust sensitivity variations by setting the  
gain of an external differential amplifier to within 1%  
interchangeability.  
Alternatives include cap-ring Models 84 or 86, ¼ NPT  
Model 96, and Model 85. High pressure sensors are also  
available.  
FEATURES  
O-ring Mount  
0.1% Pressure Non-linearity  
DIMENSIONS  
w/BACK END OPTIONS  
BASIC SENSING ELEMENT  
–20°c To +85°c Compensated  
DIAPHRAGM,  
.001 [0.03] THICK  
Ø.7413/.7427  
[18.829/18.864]  
Temperature Range  
WELD RING  
1.0% Interchangeable Span  
O-RING, BUNA-N,  
Ø.070 [1.78]  
(Provided By Gain Set Resistor)  
.54  
Solid State Reliability  
Low Power  
.24 [6.0]  
EPOXY STRAIN RELIEF  
RIBBON CABLE, 26 AWG  
4X Ø.018 [0.46]  
STANDARD RANGES  
6.00 .25  
[152.4 6.4]  
-O  
-E  
Range  
0 to 5  
0 to 15  
psig  
psia  
BALL SEAL  
Contact Factory  
CONNECTOR, FEMALE,  
MOLEX P/N 14-56-2066  
(.100 [2.54] CENTERS)  
2X .18 [4.6]  
0 to 30  
Ø.745/.747  
PAD #1  
[18.92/18.97]  
0 to 50  
+E  
+O  
2X .09 [2.3]  
0 to 100  
0 to 300  
0 to 500  
3X .05 [1.3]  
VIEW SHOWN w/o CABLE  
AND CONNECTOR FOR CLARITY  
1-60  
ISO – Standard  
316 SS Pressure Sensor  
Model 154N UltraStable  
PERFORMANCE SPECIFICATIONS  
All parameters measured at 1.5mA drive and at 25°C after 10 second warm up, unless otherwise specified. Unless specifically indicated, only those parameters  
indicated as tested are verified on each part. Parameters are specified for the compensated version only.  
PARAMETERS  
MIN  
75  
TYP  
100  
0
MAX  
150  
UNITS  
mV  
NOTES  
Full Scale Output Span  
Zero Offset  
1, 2  
2
-1  
1
mV  
Pressure Non-linearity  
Pressure Hysteresis  
-0.10  
-0.05  
2,000  
4000  
-0.75  
-0.5  
0.10  
0.05  
4,500  
25000  
0.75  
0.5  
% Span  
% Span  
3
0.02  
Input Resistance  
3,500  
Output Resistance  
Temperature Error - Span  
Temperature Error - Zero  
Thermal Hysteresis - Span  
Thermal Hysteresis - Zero  
Long Term Stability - Offset  
Long Term Stability - Span  
Supply Current  
% Span  
% Span  
% Span  
% Span  
% Span/yr.  
% Span/yr.  
mA  
4
4, 5  
4
0.05  
0.05  
0.1  
4
0.1  
0.5  
5
1.5  
2.0  
3X  
6
7
8
Output Load Resistance  
Insulation Resistance (50 VDC)  
Pressure Overload  
M  
50  
MΩ  
Rated  
Compensated Operating Temperature  
Operating Temperature Range  
Storage Temperature Range  
Media - Pressure Port  
–20°C to +85°C  
–40°C to +125°C  
–50°C to +125°C  
9
9
9
Liquids and Gases compatible with 316L Stainless Steel  
Compatible with Silicon, Pyrex, Gold, Fluorosilicone Rubber and  
316L Stainless Steel  
Media - Reference Port  
Weight  
24 g  
10  
Notes  
1. For amplified output circuits, 3.012V  
1% interchangeability with gain  
7. Load resistance to reduce measurement errors due to output loading.  
8. Between case and sensing element.  
set resistor. See Application Note TN-003.  
2. Measured at vacuum for absolute (A), ambient for gage (G).  
3. Best fit straight line.  
9. Maximum temperature range for product with standard cable and  
connector is –20°C to +105°C.  
4. Over Temperature range: -20°C to +85°C Span with respect to +25°C.  
10. Weight depends upon configuration (cable, connector).  
5. 15 psi range sensors have a temperature error of 0.75% (Max) of  
Zero from -20°C to 85°C.  
11. Standard gauge units are not recommended for vacuum applications.  
For vacuum applications, contact factory.  
6. Guarantees output/input ratiometricity.  
12. For pressure ranges < 15 psi, consult factory on performance  
specifications.  
ORDERING INFORMATION  
APPLICATION SCHEMATIC  
154N  
(Note 11)  
(Note 12)  
CONNECTIONS  
PAD NO. / CABLE  
FUNCTION  
+OUT  
-EX  
1
2
3
4
5
6
+EX  
-OUT  
GAIN  
GAIN  
June 2001  
Feel free to contact customer service with any questions at  
Toll free 1(800)745-8008; Phone (757)766-1500; Fax (757)766-4297  
ISO – Standard  
1-61  

相关型号:

154N-005G-P

Signal Conditioner
ETC

154N-005G-PT

Signal Conditioner
ETC

154N-005G-R

Signal Conditioner
ETC

154N-005G-RT

Signal Conditioner
ETC

154N-015A-C

Signal Conditioner
ETC

154N-015A-CT

Signal Conditioner
ETC

154N-015A-L

Signal Conditioner
ETC

154N-015A-LT

Signal Conditioner
ETC

154N-015A-P

Signal Conditioner
ETC

154N-015A-PT

Signal Conditioner
ETC

154N-015A-R

Signal Conditioner
ETC

154N-015A-RT

Signal Conditioner
ETC