1220A-002G-3L [ETC]
Signal Conditioner ; 信号调理\n型号: | 1220A-002G-3L |
厂家: | ETC |
描述: | Signal Conditioner
|
文件: | 总2页 (文件大小:108K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Model 1220
ꢀ Process Control
ꢀ Medical Instrumentation
ꢀ HVAC
PC Board Mountable Pressure Sensor
0-50 mV Output
ꢀ Barometric Pressure
ꢀ Air Flow Management
ꢀ Avionics
Gage, Differential and Absolute
Temperature Compensated
DESCRIPTION
The Model 1220 is a temperature compensated, piezoresistive
silicon pressure sensor packaged in a dual-in-line configuration
and intended for cost sensitive applications where excellent
performance and long-term stability are required.
Integral temperature compensation is provided over a range
of 0-50°C using laser-trimmed resistors. An additional laser-
trimmed resistor is included to normalize pressure sensitivity
variations by setting the current drive to the sensor bridge,
resulting in an interchangeability of 1% prior to amplification.
Gage, absolute, and differential pressure ranges from 0-2
PSI to 0-100 PSI are available. Multiple lead and tube
configurations are also available for customizing the package for
specific applications.
Please refer to the low pressure section for information on
products with operating pressures less than 0-2 PSI. For a
compensated sensor using a gain set resistor as opposed to a
current set resistor, please refer to the Model 1210.
FEATURES
ꢀ Dual-in-line Package
ꢀ ±±01% Non-linearity
ꢀ ±±05% Temperature Performance
DIMENSIONS
ꢀ 10±% Interchangeable Span
(provided by current set resistor)
ꢀ Solid State Reliability
ꢀ Low Power
STANDARD RANGES
Range
psia
psid
●
psig
●
± to 2
± to 5
●
●
●
●
●
●
●
± to 15
± to 3±
± to 5±
± to 1±±
●
●
●
●
●
●
●
●
1-16
HITs – Standard
PC Board Mountable Pressure Sensor
PERFORMANCE SPECIFICATIONS
Model 1220
Supply Voltage: See application schematic
Ambient Temperature: 25°C (Unless otherwise specified)
PARAMETERS
MIN
TYP
MAX
5±05
2
UNITS
mV
NOTES
Full Scale Output Span
Zero Pressure Output
Pressure Non-linearity
Pressure Hysteresis
Input & Output Resistance
Temperature Error - Span
Temperature Error - Zero
Thermal Hysteresis - Zero
Supply Current
4905
5±0±
1
2
3
±mV
±0±5
±0±1
44±±
±03
±01
±% Span
±% Span
Ω
±01
25±±
6±±±
±05
±% Span
±% Span
±% Span
mA
2, 4
±01
±05
1, 2, 4
±01
20±
3X
5
6
7
8
Response Time
10±
10±
msec
Output Noise
µV p-p
MΩ
Output Load Resistance
Insulation Resistance (5± VDC)
Pressure Overload
Operating Temperature
Storage Temperature
Weight
2
5±
MΩ
Rated
9
-4±°C to +125°C
-5±°C to +15±°C
3 Grams
Media
Non-corrosive Gases Compatible with Wetted Materials
1±
Notes
10 For 2 psi output span is 2±0± mV ± 1%, amplified span is 10232V and TC
zero temperature error is ±1025%0
80 Prevents increase of TC-Span due to output loading0
90 3X or 2±± psi maximum, whichever is less0 2± psi for 2 psi and 5 psi
versions0
20 Compensation resistors are an integral part of the sensor package; no
additional external resistors are required0 Pins 7 and 8 must be kept
open0
1±0 Wetted materials are glass, ceramic, silicon, RTV, nickel, gold, and
aluminum0
30 Best Fit Straight Line0
110 Soldering of lead pins: 25±°C for 5 seconds maximum0
120 Tube length: L=47± ± 5 mil, S=3±± ± 3 mil, N=no tube0
40 Temperature range: ±-5±°C in reference to 25°C0
50 Guarantees input/output ratiometricity0
60 For a zero-to-full scale pressure step change0
70 1± Hz to 1 kHz0
130 Lead pins can either be in the same or the opposite direction as the
pressure tube0 See Dimensions drawing for lead configurations0
CONNECTIONS
ORDERING INFORMATION
1220 A - 015 G - 3
S
Pressure Tubes (L, S, N - see note 12)
Lead Configuration (1, 3 - see note 13)
Type (G = Gage, A = Absolute, D = Differential)
Pressure Range
Grade
Model
APPLICATION SCHEMATIC
June 2±±1
Feel free to contact customer service with any questions at
Toll free 1(800)745-8008; Phone (757)766-1500; Fax (757)766-4297
HITs – Standard
1-17
相关型号: