120-107112 [ETC]

SPNO;
120-107112
型号: 120-107112
厂家: ETC    ETC
描述:

SPNO

文件: 总1页 (文件大小:53K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DC POWER  
CONTACTORS  
SPNO  
TYPE 70 SPNO  
Single Pole Normally Open Contact  
Case is Dust Resistant and Isolated from Ground  
SPECIFICATIONS  
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . 2.47L x 3.48W x 2.40H  
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 oz.  
Temperature Range . . . . . . . . . . . . . . . . . . . -40° to +122°F  
5
16  
Terminations, Contacts. . . . . . . . . . . . . . . . . / -24 UNF-2A thread  
Terminations, Coil. . . . . . . . . . . . . . . . . . . . . #10-32 UNF-2A thread  
Recommended Mounting . . . . . . . . . . . . . . . . . . . Plunger vertical with cap down  
Hardware Torque, Contact Terminal. . . . . . . . . . . 45-55 in. lbs.  
Type 70 SPNO  
WARNING – FIRE HAZARD  
Must be installed in a dry and protected  
place. Failure to protect solenoid from water  
and other contaminants could result in Fire,  
Property Damage, Serious Personal Injury,  
or Death.  
Hardware Torque, Coil Terminal . . . . . . . . . . . . . . 12-18 in. lbs.  
Caution: A back-up wrench must be used to hold the bottom nut stationary.  
Agency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . U.L. 538 Recognized, File AU2138  
Coil  
Coil  
Contact Rating (Amps) – Inductive Load  
Model  
Number  
70-111225  
70-111224  
70-117224  
70-120224  
Duty  
Cycle  
Continuous  
Continuous  
Continuous  
Continuous  
Terminal  
Type ➀  
3A  
4
Pole  
Form  
SPNO Standard  
SPNO Standard  
SPNO Standard  
SPNO Standard  
Bracket Voltage Resistance Contact  
Voltage  
D.C.  
12  
12  
24  
Normally Open  
Continuous Inrush  
Normally Closed  
Continuous  
Style  
D.C.  
12  
12  
24  
36  
(Ohms) Material  
Inrush  
60  
60  
30  
30  
16  
16  
60  
114  
Copper  
Copper  
Copper  
Copper  
80  
80  
50  
50  
400  
400  
50  
60  
60  
30  
30  
4
4
36  
50  
“3A” = Coil Grounded to Case  
“4” = Isolated Coil  
Coil resistance in Ohms @ 25°C  
Intermittent duty designs available.  
TYPE 120 SPNO  
Single Pole Normally Open Contact, Dust Resistant, Water Resistant  
and Case is Isolated from Bracket  
SPECIFICATIONS  
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 2.13L x 2.88W x 3.09H (Std. Bracket)  
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . 2.50L x 3.00W x 3.03H (L-Shaped Bracket)  
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.0 oz.  
Temperature Range, Intermittent Duty . . . . . -20° to +150°F  
Temperature Range, Continuous Duty. . . . . -20° to +120°F  
5
16  
Terminations, Contacts. . . . . . . . . . . . . . . . . / -24 studs, .495min. length  
Terminations, Coil. . . . . . . . . . . . . . . . . . . . . #10-32, .451min. length  
Recommended Mounting . . . . . . . . . . . . . . . . . . . Coil terminals up or horizontal  
Hardware Torque, Contact Terminal. . . . . . . . . . . 45-55 in. lbs.  
Hardware Torque, Coil Terminal . . . . . . . . . . . . . . 12-18 in. lbs.  
Type 120 SPNO  
Caution: A back-up wrench must be used to hold the bottom nut stationary.  
Coil  
Coil  
Contact Rating (Amps) – Inductive Load  
Voltage Normally Open  
Model  
Duty  
Terminal  
Pole  
Bracket Voltage Resistance Contact  
Number  
Cycle ➀  
Type ➁  
Form  
SPNO Standard  
SPNO Standard 12 ➄  
SPNO Standard  
SPNO  
SPNO  
Style  
D.C.  
12  
(Ohms) Material  
D.C.  
12  
12  
12  
12  
14  
Continuous  
Inrush ➃  
400  
400  
400  
400  
120-105711  
120-105851  
120-106131  
120-106132  
120-107112  
Continuous  
Continuous  
Intermittent  
Intermittent  
Continuous  
4
3A  
4
4
4
16.0  
16.0  
6.0  
Silver Alloy  
Silver Alloy  
Copper  
100  
100  
80  
80  
100  
12  
12  
14  
L
L
6.0  
Copper  
26.0  
Silver Alloy  
400  
Intermittent Duty Cycle = 30 seconds “ON” maximum and 6 minutes “OFF”  
“4” = Isolated Coil  
Coil resistance in Ohms @ 25°C  
Inrush Current: Current applied within the rst 1/2 second of contact closure  
Coil grounded to bracket  
NOTE: CAUTION must be used in coil selection for use in 12 volt  
sytems where battery charging may expose coil to continuous,  
higher-than-rated voltage. 14 volt coils are recommended.  
White-Rodgers will not be responsible for consequences of misap-  
plied solenoids.  
www.white-rodgers.com  
119a  

相关型号:

120-107131-1

Capable of handling low and high current requirements
ETC

120-107211-1

Capable of handling low and high current requirements
ETC

120-107231-1

Capable of handling low and high current requirements
ETC

120-107311-1

Capable of handling low and high current requirements
ETC

120-107331-1

Capable of handling low and high current requirements
ETC

120-107411-1

Capable of handling low and high current requirements
ETC

120-107431-1

Capable of handling low and high current requirements
ETC

120-107611-1

Capable of handling low and high current requirements
ETC

120-107631-1

Capable of handling low and high current requirements
ETC

120-107711-1

Capable of handling low and high current requirements
ETC

120-107811-1

Capable of handling low and high current requirements
ETC

120-108111-1

Capable of handling low and high current requirements
ETC