0KM3ASF [ETC]
Infrared Receiver Modules ; 红外接收器模块\n型号: | 0KM3ASF |
厂家: | ETC |
描述: | Infrared Receiver Modules
|
文件: | 总4页 (文件大小:69K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
INFRARED RECEIVER MODULE
MIM-0KM3XSF SERIES
Description
The MIM-0KM3XSF SERIES is miniaturized infrared
receivers for remote control and other applications requiring
improved ambient light rejection.
The separate PIN diode and preamplifier IC are assembled
on a single leadframe.
The epoxy package contains a special IR filter.
This module has excellent performance even in disturbed
ambient light applications and provides protection against
uncontrolled output pulses.
Features
l Photo detector and preamplifier in one package
l Internal filter for PCM frequency
l High immunity against ambient light
l Improved shielding against electric field disturbance
l 2.4-Volt supply voltage; low power consumption
l TTL and CMOS compatibility
受光面中心
MIM-0KM3XSF Series Models
l MIM-0KM3ASF 37.9KHz
l MIM-0KM3BSF 32.7KHz
l MIM-0KM3CSF 40.0KHz
l MIM-0KM3DSF 36.7KHz
l MIM-0KM3FSF 56.7KHz
UNIT : mm
BLOCK DIAGRAM
VS
TRAP
BPF
TRIMMING
Output
GND
fo
ABLC
Unity Opto Technology Co., Ltd.
01/10/2002
MIM-0KM3XSF SERIES
Absolute Maximum Ratings
@ Ta=25℃
Item
Supply voltage
Symbol
VCC
Topr
Ratings
5.8
Unit
V
Remark
Operating temperature
Storage temperature
Soldering temperature
-10 ~ + 60
-20 ~ + 75
260
℃
Tstg
℃
Tsd
℃
Maximum 5 seconds
Electro-optical characteristics (Vcc=2.4V)
(Ta=25°C , Vcc=2.4V)
Parameter
Current consumption
Symbol
Icc
Min.
Typ.
940
Max.
5.0
Unit
mA
nm
Remarks
Under no signal
Response wavelength
Tuning frequency
λp
f0
32.7,36.7,37.9,40.0,56.7
KHZ
Output form
- - - - - active low output - - - - -
V0h
V0l
H level output voltage
L level output voltage
2.2
V
V
0.5
H level output pulse width
L level output pulse width
Distance between emitter & detector
Twh
400
400
10.0
7.0
800
800
μs
μs
m
Twl
L1(Vcc=3V)
L2(Vcc=2.4V)
△Θ
Note 1
m
Half angle
±45
deg
Horizonal direction
Test Method
A. Standard Transmitter
25cm
ON/OFF pulse width satisfied from 25 cm to detection limit
+2.4V
600ms
carrier frequency f0
duty 50%
10kW
10mF
Transmitter
Duty 50%
Vout
600ms
600ms
GND
Oscilloscope
Fig 1. Burst Wave
Fig 2. Standard Transmitter Measurement circuit
B. Detection Length Test
q
q
Vout
Transmitter output
D.U.T
L
q: indicates horizontal and vertical directions
Unity Opto Technology Co., Ltd.
01/10/2002
MIM-0KM3XSF SERIES
C . Pulse Width Test
Transmitter output
DUT output pulse
600ms 600ms
Twl
Twh
V0h
V0l
Application Circuit
Vcc **)
2
MIM-0KM3XSF
102P
C
MIE-544A2
Decoder
1
3
GND
*) only necessary to supress power supply disturbances.
**) tolerated supply voltage range : 2.4V < Vcc < 5.8V
CHARACTERISTIC CURVES (TA=25℃)
900
800
700
600
500
400
2.4
2.2
Burst length * 600ms, cycle = 1.2ms
tpw: Average value of output from start
of signal input to 60th pulse
2.0
1.8
1.6
1.4
0.1
1
10
Input Level (mVp-p
100
1000
6
2
3
4
5
7
8
)
Supply Voltage Vcc (V)
INPUT LEVEL vs.OUTPUT PULSE WIDTH
NOTE 1. Distance between emitter & detector specifies maximum distance that output wave form satisfies
the standard under the conditions below against the standerd transmitter.
(1)Measuring place ………Indoor without extreme reflection of light.
(2)Ambient light source… Detecting surface illumination shall be 200±50Lux under ordinary
hite fluorescense lamp of no high frequency lighting.
(3)Standard transmitter … Burst wave indicated in Fig 1. of standard transmitter
shall be arranged to 50mVp-p under the measuring circuit specified in Fig 2.
Unity Opto Technology Co., Ltd.
01/10/2002
MIM-0KM3XSF SERIES
Reliability
Test item
Test condition
Standard
Note 2.
Note 2.
Note 2.
Note 2.
Note 3.
High temparature
High temp. & high humi.
Low temparature
Heat cycle
Ta=+60℃ Vcc=5.0 V
t=240H
t=240H
t=240H
Ta=+40℃ 90%RH Vcc=5.0V
Ta= -10℃ Vcc=5.0V
-20℃(0.5H) ~ +75℃(0.5H) 20cycle
Dropping
Test devices shall be dropped 3 times naturally
onto hard wooden board from a 75cm height position.
NOTE 2. (electro-optical charactistics) shall be satisfied after leaving 2 hours in the normal temperature .
NOTE 3. (electro-optical charactistics) shall be satisfied and no conoid deforms
and destructions of appearance .(excepting deforms of terminals)
Inspection standard
1.Among electrical characteristics , total number shall be inspected on items blow.
1-1 front distance between emitter & detector
1-2 Current consumption
1-3 H level output voltage
1-4 L level output voltage
2.Items except above mentioned are not inspected particularly , but shall fully satisfy
CAUTION ( When use and storage of this device )
1.Store and use where there is no force causing transformation or change in quality .
2.Store and use where there is no corrosive gas or sea(salt) breeze .
3.Store and use where there is no extreme humidity .
4.Solder the lead-pin within the condition of ratings. After soldering do not add extra force .
5.Do not wash this device . Wipe the stains of diode side with a soft cloth. You can
use the solvent , ethylalcohol or methylalcohol or isupropylene only .
6.To prevent static electricity damage to the Pre-AMP make sure that the human body
, the soldering iron is connected to ground before using .
7.Put decoupling device between Vcc and GND for reduse the noise from power supply line .
8.The performance of remote-control system depends on environments condition and ability
of periferal parts. Customer should evaluate the performance as total system in those conditions
after system up with components such as commander , micon and this receiver module .
Guarantee period and scope
1.Guarantee period
One year after delivery to desired place .
2.Guarantee scope
A re-delivery of goods will be carried out if the cause of malfunction lies in our
device .However no responsibilities be taken for the inconveniences caused by
the malfunction of our devices .
Others
1.This device is not design to endure radiative rays and heavily charged particles .
2.In case where any trouble or questions arise,both parties agress to make full discussion
covering the said problem .
Unity Opto Technology Co., Ltd.
01/10/2002
相关型号: