A2A150TW-1

更新时间:2024-09-18 22:10:50
品牌:ETC
描述:FORMULA UL Molded Case Circuit Breakers

A2A150TW-1 概述

FORMULA UL Molded Case Circuit Breakers

A2A150TW-1 数据手册

通过下载A2A150TW-1数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
FORMULA UL Molded Case Circuit Breakers  
A1 & A2 Frames  
A1 100A - Fixed (F) 1 pole - Front terminals (F)  
Thermomagnetic trip unit - TMF Icu (240 V)  
A1 Frames  
Rating  
A
Magnetic trip  
A
Catalog number  
A (10kA)  
Catalog number  
N (18kA)  
15  
20  
25  
30  
40  
50  
60  
70  
80  
90  
100  
400  
400  
400  
400  
400  
500  
600  
700  
800  
900  
1000  
A1A015TW-1  
A1A020TW-1  
A1A025TW-1  
A1A030TW-1  
A1A040TW-1  
A1A050TW-1  
A1A060TW-1  
A1A070TW-1  
A1A080TW-1  
A1A090TW-1  
A1A100TW-1  
A1N015TW-1  
A1N020TW-1  
A1N025TW-1  
A1N030TW-1  
A1N040TW-1  
A1N050TW-1  
A1N060TW-1  
A1N070TW-1  
A1N080TW-1  
A1N090TW-1  
A1N100TW-1  
General  
ABB‘s FORMULA molded case circuit breaker line offers simplic-  
ity and quality in some of the smallest dimensions available. The  
FORMULA A1 breaker frame size ranges in amperes from 15  
through 100 with protection trip units that have fixed thermal  
and magnetic threshold values. The frame is available in a fixed  
version with front terminals.  
A1 100A - Fixed (F) 2 pole - Front terminals (F)  
Thermomagnetic trip unit - TMF Icu (240 V)  
Rating  
A
Magnetic trip  
A
Catalog number  
A (10kA)  
Catalog number  
N (25kA)  
15  
20  
25  
30  
40  
50  
60  
70  
80  
90  
100  
400  
400  
400  
400  
400  
500  
600  
700  
800  
900  
1000  
A1A015TW-2  
A1A020TW-2  
A1A025TW-2  
A1A030TW-2  
A1A040TW-2  
A1A050TW-2  
A1A060TW-2  
A1A070TW-2  
A1A080TW-2  
A1A090TW-2  
A1A100TW-2  
A1N015TW-2  
A1N020TW-2  
A1N025TW-2  
A1N030TW-2  
A1N040TW-2  
A1N050TW-2  
A1N060TW-2  
A1N070TW-2  
A1N080TW-2  
A1N090TW-2  
A1N100TW-2  
Standards  
UL 489 & IEC 60947-2  
Dimensions (w x d x h):  
1 pole: 1.00" x 2.36" x 5.12"  
2 pole: 2.00" x 2.36" x 5.12"  
3 pole: 3.00" x 2.36" x 5.12"  
Weight:  
1 pole: 0.54 lbs  
A1 100A - Fixed (F) 3 pole - Front terminals (F)  
Thermomagnetic trip unit - TMF Icu (240 V)  
2 pole: 1.04 lbs  
3 pole: 1.54 lbs  
Rating  
A
Magnetic trip  
A
Catalog number  
A (10kA)  
Catalog number  
N (25kA)  
Available Accessories:  
Shunt opening release (2p & 3p)  
Undervoltage release (2p & 3p)  
Auxiliary contacts (2p & 3p)  
Termination kits (1p, 2p & 3p)  
Padlocks (1p, 2p & 3p)  
Direct and extended rotary handles (3p)  
15  
20  
25  
30  
40  
50  
60  
70  
80  
90  
100  
300  
300  
300  
300  
400  
500  
600  
700  
800  
900  
1000  
A1A015TW  
A1A020TW  
A1A025TW  
A1A030TW  
A1A040TW  
A1A050TW  
A1A060TW  
A1A070TW  
A1A080TW  
A1A090TW  
A1A100TW  
A1N015TW  
A1N020TW  
A1N025TW  
A1N030TW  
A1N040TW  
A1N050TW  
A1N060TW  
A1N070TW  
A1N080TW  
A1N090TW  
A1N100TW  
Power and productivity  
for a better worldTM  
A2 250A - Fixed (F) 1 pole - Front terminals (F)  
Thermomagnetic trip unit - TMF Icu (240 V)  
A2 Frames  
Rating  
A
Magnetic trip  
A
Catalog number  
A (10kA)  
Catalog number  
N (14kA)  
125  
150  
175  
200  
225  
250  
1250  
1500  
1750  
2000  
2250  
2500  
A2A125TW-1  
A2A150TW-1  
A2A175TW-1  
A2A200TW-1  
A2A225TW-1  
A2A250TW-1  
A2N125TW-1  
A2N150TW-1  
A2N175TW-1  
A2N200TW-1  
A2N225TW-1  
A2N250TW-1  
A2 250A - Fixed (F) 2 pole - Front terminals (F)  
Thermomagnetic trip unit - TMF Icu (240 V)  
Rating  
A
Magnetic trip  
A
Catalog number  
A (10kA)  
Catalog number  
N (25kA)  
General  
ABBs FORMULA molded case circuit breaker line offers simplic-  
ity and quality in some of the smallest dimensions available. The  
FORMULA A2 breaker frame size ranges in amperes from 125  
through 250 with protection trip units that have fixed thermal  
and magnetic threshold values. The frame is available in a fixed  
version with front terminals.  
125  
150  
175  
200  
225  
250  
1250  
1500  
1750  
2000  
2250  
2500  
A2A125TW-2  
A2A150TW-2  
A2A175TW-2  
A2A200TW-2  
A2A225TW-2  
A2A250TW-2  
A2N125TW-2  
A2N150TW-2  
A2N175TW-2  
A2N200TW-2  
A2N225TW-2  
A2N250TW-2  
Standards  
A2 250A - Fixed (F) 3 pole - Front terminals (F)  
Thermomagnetic trip unit - TMF Icu (240 V)  
UL 489 & IEC 60947-2  
Dimensions (w x d x h):  
1 pole: 1.38" x 2.36" x 5.91"  
2 pole: 2.76" x 2.36" x 5.91"  
3 pole: 4.13" x 2.36" x 5.91"  
Weight:  
Rating  
A
Magnetic trip  
A
Catalog number  
A (10kA)  
Catalog number  
N (25kA)  
125  
150  
175  
200  
225  
250  
1250  
1500  
1750  
2000  
2250  
2500  
A2A125TW  
A2A150TW  
A2A175TW  
A2A200TW  
A2A225TW  
A2A250TW  
A2N125TW  
A2N150TW  
A2N175TW  
A2N200TW  
A2N225TW  
A2N250TW  
1 pole: 0.82 lbs  
2 pole: 1.61 lbs  
3 pole: 2.43 lbs  
Available Accessories:  
Shunt opening release (2p & 3p)  
Undervoltage release (2p & 3p)  
Auxiliary contacts (2p & 3p)  
Termination kits (1p, 2p & 3p)  
Padlocks (1p, 2p & 3p)  
Direct and extended rotary handles (3p)  
ABB Inc.  
Low Voltage Control Products  
16250 W. Glendale Drive  
New Berlin, WI 53151  
Phone: 888-385-1221  
Fax:  
800-726-1441  
USA Technical Support & Customer Service:  
888-385-1221, Option 4  
7:30AM to 5:30PM, CST,  
Monday - Friday  
lvps.support@us.abb.com  
Web: www.abb.us/lowvoltage  
Power and productivity  
for a better worldTM  

A2A150TW-1 相关器件

型号 制造商 描述 价格 文档
A2A150TW-2 ETC FORMULA UL Molded Case Circuit Breakers 获取价格
A2A175TW ETC FORMULA UL Molded Case Circuit Breakers 获取价格
A2A175TW-1 ETC FORMULA UL Molded Case Circuit Breakers 获取价格
A2A175TW-2 ETC FORMULA UL Molded Case Circuit Breakers 获取价格
A2A200TW ETC FORMULA UL Molded Case Circuit Breakers 获取价格
A2A200TW-1 ETC FORMULA UL Molded Case Circuit Breakers 获取价格
A2A200TW-2 ETC FORMULA UL Molded Case Circuit Breakers 获取价格
A2A225TW ETC FORMULA UL Molded Case Circuit Breakers 获取价格
A2A225TW-1 ETC FORMULA UL Molded Case Circuit Breakers 获取价格
A2A225TW-2 ETC FORMULA UL Molded Case Circuit Breakers 获取价格

A2A150TW-1 相关文章

  • Bourns 密封通孔金属陶瓷微调电位计产品选型手册(英文版)
    2024-09-20
    6
  • Bourns 精密环境传感器产品选型手册(英文版)
    2024-09-20
    9
  • Bourns POWrTher 负温度系数(NTC)热敏电阻手册 (英文版)
    2024-09-20
    8
  • Bourns GMOV 混合过压保护组件产品选型手册(英文版)
    2024-09-20
    6