B57862S0282F040 [EPCOS]

RESISTOR, TEMPERATURE DEPENDENT, NTC, 2800ohm, CHASSIS MOUNT, RADIAL LEADED;
B57862S0282F040
型号: B57862S0282F040
厂家: EPCOS    EPCOS
描述:

RESISTOR, TEMPERATURE DEPENDENT, NTC, 2800ohm, CHASSIS MOUNT, RADIAL LEADED

温度传感 电阻器
文件: 总17页 (文件大小:266K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
NTC thermistors for  
temperature measurement  
Miniature sensors  
with bendable wires  
Series/Type:  
B57862  
Date:  
March 2006  
© EPCOS AG 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the  
information contained therein without EPCOS' prior express consent is prohibited.  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
Applications  
Dimensional drawing  
Heating and air conditioning systems  
Industrial electronics  
Automotive electronics  
Features  
Improved resistance to humidity  
Fast response  
High measuring accuracy  
Different tolerances available  
Epoxy resin encapsulation  
Insulated leads of silver-plated  
nickel wire, AWG 30  
UL approval (E69802)  
Options  
Non-standard lead lengths  
Delivery mode  
Dimensions in mm  
Bulk  
Approx. weight 60 mg  
General technical data  
Climatic category  
Max. power  
(IEC 60068-1)  
(at 25 °C)  
55/155/56  
60  
RR/RR ±1, ±3, ±5  
P25  
mW  
%
°C  
mW/K  
s
mJ/K  
Resistance tolerance  
Rated temperature  
Dissipation factor  
Thermal cooling time constant  
Heat capacity  
TR  
δth  
τc  
25  
(in air)  
(in air)  
approx. 1.7  
approx. 21  
approx. 36  
Cth  
Electrical specification and ordering codes  
R25  
No. of R/T  
B25/100  
Ordering code  
characteristic  
K
2.8 k  
5 k  
10 k  
8016  
8016  
8016  
3988 ±1%  
3988 ±1%  
3988 ±1%  
B57862S0282+040  
B57862S0502+040  
B57862S0103+040  
+ = Resistance tolerance  
F = ±1%  
H = ±3%  
J = ±5%  
Please read Important notes and  
Page 2 of 17  
Cautions and warnings at the end of this document.  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
Note  
The type series S862 has a specially designed insulation (coating, wire coating) to withstand the  
immersion test in water of 1000 h, 25 °C. Therefore these sensors must be protected to avoid any  
damage of the insulation material during handling and in the application.  
Reliability data  
Test  
Standard  
IEC  
Test conditions  
R25/R25  
(typical)  
Remarks  
Storage in  
dry heat  
Storage at upper  
< 2%  
No visible  
damage  
60068-2-2 category temperature  
T: 155 °C  
t: 1000 h  
Storage in damp  
heat, steady state  
IEC  
Temperature of air: 40 °C  
< 1%  
No visible  
damage  
60068-2-78 Relative humidity of air: 93%  
Duration: 56 days  
Rapid temperature IEC  
Lower test temperature: 55 °C < 1%  
No visible  
damage  
cycling  
60068-2-14 Upper test temperature: 155 °C  
Number of cycles: 100  
Immersion test  
Test voltage 2.7 VDC on NTC  
over protective resistor, sensors  
immersed into water, ambient  
temperature (25 °C), voltage  
switched on 5 h switched off 1 h.  
t: 1000 h  
< 2%  
No visible  
damage  
Long-term stability  
(empirical value)  
Temperature: 70 °C  
t: 10000 h  
< 2%  
No visible  
damage  
Please read Important notes and  
Page 3 of 17  
Cautions and warnings at the end of this document.  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
R/T characteristics  
B57862S0282F040  
R/T No.  
8016  
T (°C)  
B25/100 = 3988 K, R25 = 2800 , TR = 25 °C, RR/RR = ± 1%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
55.0  
6.0  
5.5  
5.2  
4.8  
4.4  
0.8  
0.8  
0.7  
0.7  
0.7  
7.4  
7.1  
6.9  
6.7  
6.4  
285710  
198030  
138880  
98723  
269650  
187630  
132070  
94220  
253600  
177220  
125270  
89717  
50.0  
45.0  
40.0  
35.0  
70927  
67925  
64923  
30.0  
25.0  
20.0  
15.0  
10.0  
4.1  
3.7  
3.4  
3.1  
2.8  
0.7  
0.6  
0.6  
0.6  
0.5  
6.2  
6.0  
5.8  
5.6  
5.4  
51580  
37871  
28111  
21058  
15931  
49560  
36504  
27180  
20420  
15492  
47540  
35136  
26248  
19783  
15054  
5.0  
0.0  
5.0  
10.0  
15.0  
2.5  
2.3  
2.0  
1.8  
1.5  
0.5  
0.4  
0.4  
0.4  
0.3  
5.3  
5.1  
5.0  
4.8  
4.7  
12150  
9350  
7252  
5670  
4465  
11848  
9142  
7109  
5572  
4398  
11546  
8934  
6966  
5474  
4332  
20.0  
25.0  
30.0  
35.0  
40.0  
1.3  
1.0  
1.3  
1.5  
1.7  
0.3  
0.2  
0.3  
0.4  
0.4  
4.5  
4.4  
4.3  
4.1  
4.0  
3542  
2828  
2285  
1856  
1517  
3497  
2800  
2256  
1829  
1492  
3453  
2772  
2227  
1802  
1466  
45.0  
50.0  
55.0  
60.0  
65.0  
1.9  
2.1  
2.3  
2.5  
2.6  
0.5  
0.5  
0.6  
0.7  
0.8  
3.9  
3.8  
3.7  
3.6  
3.5  
1246  
1030  
855.1  
713.7  
598.6  
1223  
1009  
836.1  
696.6  
583.3  
1200  
987.8  
817.1  
679.5  
567.9  
70.0  
75.0  
80.0  
85.0  
90.0  
490.6  
414.8  
352.2  
300.3  
257.0  
476.8  
402.5  
341.2  
290.4  
248.1  
504.3  
427.1  
363.3  
310.1  
265.8  
2.8  
3.0  
3.1  
3.3  
3.4  
0.8  
0.9  
1.0  
1.0  
1.1  
3.4  
3.3  
3.2  
3.2  
3.1  
95.0  
100.0  
105.0  
110.0  
115.0  
220.8  
190.4  
164.8  
143.1  
124.7  
212.9  
183.3  
158.4  
137.4  
119.5  
228.7  
197.5  
171.2  
148.9  
129.9  
3.6  
3.7  
3.9  
4.0  
4.2  
1.2  
1.3  
1.4  
1.4  
1.5  
3.0  
2.9  
2.9  
2.8  
2.7  
120.0  
125.0  
130.0  
135.0  
109.0  
95.68  
84.25  
74.32  
104.3  
91.46  
80.43  
70.86  
113.7  
99.89  
88.07  
77.78  
4.3  
4.4  
4.5  
4.7  
1.6  
1.7  
1.8  
1.9  
2.7  
2.6  
2.5  
2.5  
Please read Important notes and  
Cautions and warnings at the end of this document.  
Page 4 of 17  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
B57862S0282F040  
R/T No.  
8016  
T (°C)  
B25/100 = 3988 K, R25 = 2800 , TR = 25 °C, RR/RR = ± 1%  
Rnom[]  
65.74  
Rmin[]  
62.61  
Rmax[]  
68.88  
RR/RR[±%] T[±°C]  
α (%/K)  
140.0  
4.8  
2.0  
2.4  
145.0  
150.0  
155.0  
58.33  
51.88  
46.30  
55.48  
49.29  
43.93  
61.18  
54.48  
48.66  
4.9  
5.0  
5.1  
2.1  
2.2  
2.3  
2.4  
2.3  
2.3  
B57862S0282H040  
R/T No.  
T (°C)  
8016  
B25/100 = 3988 K, R25 = 2800 , TR = 25 °C, RR/RR = ± 3%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
55.0  
8.0  
7.5  
7.2  
6.8  
6.4  
1.1  
1.1  
1.0  
1.0  
1.0  
7.4  
7.1  
6.9  
6.7  
6.4  
291110  
201790  
141520  
100610  
72286  
269650  
187630  
132070  
94220  
248200  
173470  
122620  
87833  
50.0  
45.0  
40.0  
35.0  
67925  
63564  
30.0  
25.0  
20.0  
15.0  
10.0  
6.1  
5.7  
5.4  
5.1  
4.8  
1.0  
1.0  
0.9  
0.9  
0.9  
6.2  
6.0  
5.8  
5.6  
5.4  
52571  
38601  
28655  
21466  
16241  
49560  
36504  
27180  
20420  
15492  
46549  
34406  
25704  
19374  
14744  
5.0  
0.0  
5.0  
10.0  
15.0  
4.5  
4.3  
4.0  
3.8  
3.5  
0.9  
0.8  
0.8  
0.8  
0.8  
5.3  
5.1  
5.0  
4.8  
4.7  
12387  
9533  
7394  
5781  
4553  
11848  
9142  
7109  
5572  
4398  
11310  
8751  
6823  
5363  
4244  
20.0  
25.0  
30.0  
35.0  
40.0  
3.3  
3.0  
3.3  
3.5  
3.7  
0.7  
0.7  
0.8  
0.8  
0.9  
4.5  
4.4  
4.3  
4.1  
4.0  
3612  
2884  
2330  
1892  
1547  
3497  
2800  
2256  
1829  
1492  
3383  
2716  
2182  
1765  
1437  
45.0  
50.0  
55.0  
60.0  
65.0  
3.9  
4.1  
4.3  
4.5  
4.6  
1.0  
1.1  
1.2  
1.2  
1.3  
3.9  
3.8  
3.7  
3.6  
3.5  
1271  
1050  
871.9  
727.7  
610.3  
1223  
1009  
836.1  
696.6  
583.3  
1176  
967.6  
800.4  
665.6  
556.2  
70.0  
75.0  
80.0  
85.0  
90.0  
490.6  
414.8  
352.2  
300.3  
257.0  
467.0  
394.2  
334.2  
284.4  
243.0  
514.1  
435.4  
370.3  
316.1  
270.9  
4.8  
5.0  
5.1  
5.3  
5.4  
1.4  
1.5  
1.6  
1.7  
1.8  
3.4  
3.3  
3.2  
3.2  
3.1  
Please read Important notes and  
Cautions and warnings at the end of this document.  
Page 5 of 17  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
B57862S0282H040  
R/T No.  
8016  
T (°C)  
B25/100 = 3988 K, R25 = 2800 , TR = 25 °C, RR/RR = ± 3%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
95.0  
220.8  
208.4  
233.1  
5.6  
5.7  
5.9  
6.0  
6.2  
1.9  
2.0  
2.1  
2.2  
2.3  
3.0  
2.9  
2.9  
2.8  
2.7  
100.0  
105.0  
110.0  
115.0  
190.4  
164.8  
143.1  
124.7  
179.5  
155.1  
134.5  
117.0  
201.3  
174.5  
151.7  
132.4  
120.0  
125.0  
130.0  
135.0  
140.0  
109.0  
95.68  
84.25  
74.32  
65.74  
102.2  
89.54  
78.75  
69.38  
61.29  
115.9  
101.8  
89.76  
79.27  
70.20  
6.3  
6.4  
6.5  
6.7  
6.8  
2.4  
2.5  
2.6  
2.7  
2.8  
2.7  
2.6  
2.5  
2.5  
2.4  
145.0  
150.0  
155.0  
58.33  
51.88  
46.30  
54.31  
48.25  
43.00  
62.35  
55.52  
49.59  
6.9  
7.0  
7.1  
2.9  
3.0  
3.1  
2.4  
2.3  
2.3  
B57862S0282J040  
R/T No.  
T (°C)  
8016  
B25/100 = 3988 K, R25 = 2800 , TR = 25 °C, RR/RR = ± 5%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
55.0  
10.0  
9.5  
9.2  
8.8  
8.4  
1.3  
1.3  
1.3  
1.3  
1.3  
7.4  
7.1  
6.9  
6.7  
6.4  
296500  
205540  
144160  
102490  
73644  
269650  
187630  
132070  
94220  
242810  
169720  
119980  
85948  
50.0  
45.0  
40.0  
35.0  
67925  
62206  
30.0  
25.0  
20.0  
15.0  
10.0  
8.1  
7.7  
7.4  
7.1  
6.8  
1.3  
1.3  
1.3  
1.3  
1.3  
6.2  
6.0  
5.8  
5.6  
5.4  
53562  
39331  
29198  
21875  
16550  
49560  
36504  
27180  
20420  
15492  
45558  
33676  
25161  
18966  
14434  
5.0  
0.0  
5.0  
10.0  
15.0  
6.5  
6.3  
6.0  
5.8  
5.5  
1.2  
1.2  
1.2  
1.2  
1.2  
5.3  
5.1  
5.0  
4.8  
4.7  
12624  
9716  
7536  
5893  
4641  
11848  
9142  
7109  
5572  
4398  
11073  
8568  
6681  
5251  
4156  
20.0  
25.0  
30.0  
35.0  
40.0  
5.3  
5.0  
5.3  
5.5  
5.7  
1.2  
1.1  
1.2  
1.3  
1.4  
4.5  
4.4  
4.3  
4.1  
4.0  
3682  
2940  
2375  
1929  
1576  
3497  
2800  
2256  
1829  
1492  
3313  
2660  
2137  
1728  
1407  
45.0  
5.9  
1.5  
3.9  
1295  
1223  
1151  
Please read Important notes and  
Cautions and warnings at the end of this document.  
Page 6 of 17  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
B57862S0282J040  
R/T No.  
8016  
T (°C)  
B25/100 = 3988 K, R25 = 2800 , TR = 25 °C, RR/RR = ± 5%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
50.0  
947.5  
6.1  
6.3  
6.5  
6.6  
1.6  
1.7  
1.8  
1.9  
3.8  
3.7  
3.6  
3.5  
1070  
888.6  
741.6  
621.9  
1009  
836.1  
696.6  
583.3  
55.0  
60.0  
65.0  
783.7  
651.7  
544.6  
70.0  
75.0  
80.0  
85.0  
90.0  
490.6  
414.8  
352.2  
300.3  
257.0  
457.2  
385.9  
327.1  
278.4  
237.8  
523.9  
443.7  
377.4  
322.1  
276.1  
6.8  
7.0  
7.1  
7.3  
7.4  
2.0  
2.1  
2.2  
2.3  
2.4  
3.4  
3.3  
3.2  
3.2  
3.1  
95.0  
100.0  
105.0  
110.0  
115.0  
220.8  
190.4  
164.8  
143.1  
124.7  
204.0  
175.7  
151.8  
131.7  
114.5  
237.5  
205.1  
177.8  
154.6  
134.9  
7.6  
7.7  
7.9  
8.0  
8.2  
2.5  
2.6  
2.8  
2.9  
3.0  
3.0  
2.9  
2.9  
2.8  
2.7  
120.0  
125.0  
130.0  
135.0  
140.0  
109.0  
95.68  
84.25  
74.32  
65.74  
99.98  
87.63  
77.06  
67.89  
59.98  
118.0  
103.7  
91.44  
80.76  
71.51  
8.3  
8.4  
8.5  
8.7  
8.8  
3.1  
3.2  
3.4  
3.5  
3.6  
2.7  
2.6  
2.5  
2.5  
2.4  
145.0  
150.0  
155.0  
58.33  
51.88  
46.30  
53.15  
47.21  
42.08  
63.51  
56.55  
50.52  
8.9  
9.0  
9.1  
3.8  
3.9  
4.0  
2.4  
2.3  
2.3  
B57862S0502F040  
R/T No.  
T (°C)  
8016  
B25/100 = 3988 K, R25 = 5000 , TR = 25 °C, RR/RR = ± 1%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
55.0  
6.0  
5.5  
5.2  
4.8  
4.4  
0.8  
0.8  
0.7  
0.7  
0.7  
7.4  
7.1  
6.9  
6.7  
6.4  
510200  
353630  
248000  
176290  
126660  
481520  
335050  
235840  
168250  
121300  
452850  
316470  
223690  
160210  
115930  
50.0  
45.0  
40.0  
35.0  
30.0  
25.0  
20.0  
15.0  
10.0  
4.1  
3.7  
3.4  
3.1  
2.8  
0.7  
0.6  
0.6  
0.6  
0.5  
6.2  
6.0  
5.8  
5.6  
5.4  
92107  
67626  
50199  
37603  
28448  
88500  
65185  
48535  
36465  
27665  
84893  
62744  
46871  
35326  
26882  
5.0  
0.0  
2.5  
2.3  
0.5  
0.4  
5.3  
5.1  
21696  
16696  
21158  
16325  
20619  
15954  
Please read Important notes and  
Cautions and warnings at the end of this document.  
Page 7 of 17  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
B57862S0502F040  
R/T No.  
8016  
T (°C)  
B25/100 = 3988 K, R25 = 5000 , TR = 25 °C, RR/RR = ± 1%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
5.0  
10.0  
15.0  
2.0  
1.8  
1.5  
0.4  
0.4  
0.3  
5.0  
4.8  
4.7  
12949  
10125  
7973  
12694  
9950  
7854  
12438  
9775  
7735  
20.0  
25.0  
30.0  
35.0  
40.0  
1.3  
1.0  
1.3  
1.5  
1.7  
0.3  
0.2  
0.3  
0.4  
0.4  
4.5  
4.4  
4.3  
4.1  
4.0  
6325  
5050  
4080  
3314  
2709  
6245  
5000  
4029  
3266  
2664  
6165  
4950  
3977  
3217  
2618  
45.0  
50.0  
55.0  
60.0  
65.0  
1.9  
2.1  
2.3  
2.5  
2.6  
0.5  
0.5  
0.6  
0.7  
0.8  
3.9  
3.8  
3.7  
3.6  
3.5  
2226  
1839  
1527  
1275  
1069  
2184  
1802  
1493  
1244  
1042  
2143  
1764  
1459  
1213  
1014  
70.0  
75.0  
80.0  
85.0  
90.0  
876.0  
851.4  
900.6  
2.8  
3.0  
3.1  
3.3  
3.4  
0.8  
0.9  
1.0  
1.0  
1.1  
3.4  
3.3  
3.2  
3.2  
3.1  
740.7  
629.0  
536.2  
458.8  
718.7  
609.3  
518.5  
443.0  
762.7  
648.7  
553.8  
474.7  
95.0  
100.0  
105.0  
110.0  
115.0  
394.3  
340.0  
294.3  
255.6  
222.7  
380.1  
327.3  
282.9  
245.3  
213.5  
408.4  
352.7  
305.7  
265.9  
231.9  
3.6  
3.7  
3.9  
4.0  
4.2  
1.2  
1.3  
1.4  
1.4  
1.5  
3.0  
2.9  
2.9  
2.8  
2.7  
120.0  
125.0  
130.0  
135.0  
140.0  
194.7  
170.9  
150.5  
132.7  
117.4  
186.3  
163.3  
143.6  
126.5  
111.8  
203.0  
178.4  
157.3  
138.9  
123.0  
4.3  
4.4  
4.5  
4.7  
4.8  
1.6  
1.7  
1.8  
1.9  
2.0  
2.7  
2.6  
2.5  
2.5  
2.4  
145.0  
150.0  
155.0  
104.2  
92.65  
82.67  
99.07  
88.02  
78.45  
109.3  
97.28  
86.90  
4.9  
5.0  
5.1  
2.1  
2.2  
2.3  
2.4  
2.3  
2.3  
B57862S0502H040  
R/T No.  
T (°C)  
8016  
B25/100 = 3988 K, R25 = 5000 , TR = 25 °C, RR/RR = ± 3%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
55.0  
50.0  
45.0  
8.0  
7.5  
7.2  
1.1  
1.1  
1.0  
7.4  
7.1  
6.9  
519830  
360330  
252720  
481520  
335050  
235840  
443220  
309770  
218970  
Please read Important notes and  
Cautions and warnings at the end of this document.  
Page 8 of 17  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
B57862S0502H040  
R/T No.  
8016  
T (°C)  
B25/100 = 3988 K, R25 = 5000 , TR = 25 °C, RR/RR = ± 3%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
40.0  
35.0  
6.8  
6.4  
1.0  
1.0  
6.7  
6.4  
179660  
129080  
168250  
121300  
156840  
113510  
30.0  
25.0  
20.0  
15.0  
10.0  
6.1  
5.7  
5.4  
5.1  
4.8  
1.0  
1.0  
0.9  
0.9  
0.9  
6.2  
6.0  
5.8  
5.6  
5.4  
93877  
68930  
51169  
38332  
29001  
88500  
65185  
48535  
36465  
27665  
83123  
61440  
45901  
34597  
26329  
5.0  
0.0  
5.0  
10.0  
15.0  
4.5  
4.3  
4.0  
3.8  
3.5  
0.9  
0.8  
0.8  
0.8  
0.8  
5.3  
5.1  
5.0  
4.8  
4.7  
22119  
17023  
13203  
10324  
8130  
21158  
16325  
12694  
9950  
20196  
15627  
12185  
9576  
7854  
7578  
20.0  
25.0  
30.0  
35.0  
40.0  
3.3  
3.0  
3.3  
3.5  
3.7  
0.7  
0.7  
0.8  
0.8  
0.9  
4.5  
4.4  
4.3  
4.1  
4.0  
6450  
5150  
4160  
3379  
2762  
6245  
5000  
4029  
3266  
2664  
6040  
4850  
3897  
3152  
2565  
45.0  
50.0  
55.0  
60.0  
65.0  
3.9  
4.1  
4.3  
4.5  
4.6  
1.0  
1.1  
1.2  
1.2  
1.3  
3.9  
3.8  
3.7  
3.6  
3.5  
2269  
1875  
1557  
1299  
1090  
2184  
1802  
1493  
1244  
1042  
2099  
1728  
1429  
1189  
993.3  
70.0  
75.0  
80.0  
85.0  
90.0  
876.0  
833.9  
703.9  
596.7  
507.8  
433.9  
918.1  
4.8  
5.0  
5.1  
5.3  
5.4  
1.4  
1.5  
1.6  
1.7  
1.8  
3.4  
3.3  
3.2  
3.2  
3.1  
740.7  
629.0  
536.2  
458.8  
777.5  
661.3  
564.5  
483.8  
95.0  
100.0  
105.0  
110.0  
115.0  
394.3  
340.0  
294.3  
255.6  
222.7  
372.2  
320.5  
277.0  
240.2  
209.0  
416.3  
359.5  
311.6  
271.0  
236.4  
5.6  
5.7  
5.9  
6.0  
6.2  
1.9  
2.0  
2.1  
2.2  
2.3  
3.0  
2.9  
2.9  
2.8  
2.7  
120.0  
125.0  
130.0  
135.0  
140.0  
194.7  
170.9  
150.5  
132.7  
117.4  
182.4  
159.9  
140.6  
123.9  
109.4  
206.9  
181.8  
160.3  
141.6  
125.4  
6.3  
6.4  
6.5  
6.7  
6.8  
2.4  
2.5  
2.6  
2.7  
2.8  
2.7  
2.6  
2.5  
2.5  
2.4  
145.0  
150.0  
155.0  
104.2  
92.65  
82.67  
96.99  
86.16  
76.79  
111.3  
99.14  
88.55  
6.9  
7.0  
7.1  
2.9  
3.0  
3.1  
2.4  
2.3  
2.3  
Please read Important notes and  
Cautions and warnings at the end of this document.  
Page 9 of 17  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
B57862S0502J040  
R/T No.  
8016  
T (°C)  
B25/100 = 3988 K, R25 = 5000 , TR = 25 °C, RR/RR = ± 5%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
55.0  
10.0  
9.5  
9.2  
8.8  
8.4  
1.3  
1.3  
1.3  
1.3  
1.3  
7.4  
7.1  
6.9  
6.7  
6.4  
529460  
367030  
257430  
183020  
131510  
481520  
335050  
235840  
168250  
121300  
433590  
303070  
214260  
153480  
111080  
50.0  
45.0  
40.0  
35.0  
30.0  
25.0  
20.0  
15.0  
10.0  
8.1  
7.7  
7.4  
7.1  
6.8  
1.3  
1.3  
1.3  
1.3  
1.3  
6.2  
6.0  
5.8  
5.6  
5.4  
95647  
70234  
52140  
39062  
29554  
88500  
65185  
48535  
36465  
27665  
81353  
60136  
44930  
33867  
25776  
5.0  
0.0  
5.0  
10.0  
15.0  
6.5  
6.3  
6.0  
5.8  
5.5  
1.2  
1.2  
1.2  
1.2  
1.2  
5.3  
5.1  
5.0  
4.8  
4.7  
22543  
17349  
13457  
10523  
8287  
21158  
16325  
12694  
9950  
19772  
15301  
11931  
9377  
7854  
7421  
20.0  
25.0  
30.0  
35.0  
40.0  
5.3  
5.0  
5.3  
5.5  
5.7  
1.2  
1.1  
1.2  
1.3  
1.4  
4.5  
4.4  
4.3  
4.1  
4.0  
6575  
5250  
4241  
3445  
2815  
6245  
5000  
4029  
3266  
2664  
5915  
4750  
3816  
3087  
2512  
45.0  
50.0  
55.0  
60.0  
65.0  
5.9  
6.1  
6.3  
6.5  
6.6  
1.5  
1.6  
1.7  
1.8  
1.9  
3.9  
3.8  
3.7  
3.6  
3.5  
2313  
1911  
1587  
1324  
1111  
2184  
1802  
1493  
1244  
1042  
2056  
1692  
1399  
1164  
972.4  
70.0  
75.0  
80.0  
85.0  
90.0  
876.0  
816.4  
689.1  
584.1  
497.1  
424.7  
935.6  
6.8  
7.0  
7.1  
7.3  
7.4  
2.0  
2.1  
2.2  
2.3  
2.4  
3.4  
3.3  
3.2  
3.2  
3.1  
740.7  
629.0  
536.2  
458.8  
792.3  
673.9  
575.3  
493.0  
95.0  
100.0  
105.0  
110.0  
115.0  
394.3  
340.0  
294.3  
255.6  
222.7  
364.3  
313.7  
271.1  
235.1  
204.6  
424.2  
366.3  
317.5  
276.1  
240.9  
7.6  
7.7  
7.9  
8.0  
8.2  
2.5  
2.6  
2.8  
2.9  
3.0  
3.0  
2.9  
2.9  
2.8  
2.7  
120.0  
125.0  
130.0  
135.0  
194.7  
170.9  
150.5  
132.7  
178.5  
156.5  
137.6  
121.2  
210.8  
185.2  
163.3  
144.2  
8.3  
8.4  
8.5  
8.7  
3.1  
3.2  
3.4  
3.5  
2.7  
2.6  
2.5  
2.5  
Please read Important notes and  
Cautions and warnings at the end of this document.  
Page 10 of 17  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
B57862S0502J040  
R/T No.  
8016  
T (°C)  
B25/100 = 3988 K, R25 = 5000 , TR = 25 °C, RR/RR = ± 5%  
Rnom[]  
117.4  
Rmin[]  
107.1  
Rmax[]  
127.7  
RR/RR[±%] T[±°C]  
α (%/K)  
140.0  
8.8  
3.6  
2.4  
145.0  
150.0  
155.0  
104.2  
92.65  
82.67  
94.90  
84.31  
75.14  
113.4  
101.0  
90.21  
8.9  
9.0  
9.1  
3.8  
3.9  
4.0  
2.4  
2.3  
2.3  
B57862S0103F040  
R/T No.  
T (°C)  
8016  
B25/100 = 3988 K, R25 = 10000 , TR = 25 °C, RR/RR = ± 1%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
55.0  
6.0  
5.5  
5.2  
4.8  
4.4  
0.8  
0.8  
0.7  
0.7  
0.7  
7.4  
7.1  
6.9  
6.7  
6.4  
1020400  
707260  
496000  
352580  
253310  
963050  
670100  
471690  
336500  
242590  
905700  
632940  
447380  
320420  
231870  
50.0  
45.0  
40.0  
35.0  
30.0  
25.0  
20.0  
15.0  
10.0  
4.1  
3.7  
3.4  
3.1  
2.8  
0.7  
0.6  
0.6  
0.6  
0.5  
6.2  
6.0  
5.8  
5.6  
5.4  
184210  
135250  
100400  
75206  
177000  
130370  
97070  
72929  
55330  
169790  
125490  
93743  
70652  
53765  
56895  
5.0  
0.0  
5.0  
10.0  
15.0  
2.5  
2.3  
2.0  
1.8  
1.5  
0.5  
0.4  
0.4  
0.4  
0.3  
5.3  
5.1  
5.0  
4.8  
4.7  
43393  
33393  
25898  
20250  
15946  
42315  
32650  
25388  
19900  
15708  
41237  
31907  
24877  
19550  
15470  
20.0  
25.0  
30.0  
35.0  
40.0  
1.3  
1.0  
1.3  
1.5  
1.7  
0.3  
0.2  
0.3  
0.4  
0.4  
4.5  
4.4  
4.3  
4.1  
4.0  
12650  
10100  
8159  
6628  
5417  
12490  
10000  
8057  
6531  
5327  
12330  
9900  
7955  
6434  
5237  
45.0  
50.0  
55.0  
60.0  
65.0  
1.9  
2.1  
2.3  
2.5  
2.6  
0.5  
0.5  
0.6  
0.7  
0.8  
3.9  
3.8  
3.7  
3.6  
3.5  
4451  
3678  
3054  
2549  
2138  
4369  
3603  
2986  
2488  
2083  
4286  
3528  
2918  
2427  
2028  
70.0  
75.0  
80.0  
85.0  
90.0  
2.8  
3.0  
3.1  
3.3  
3.4  
0.8  
0.9  
1.0  
1.0  
1.1  
3.4  
3.3  
3.2  
3.2  
3.1  
1801  
1525  
1297  
1108  
1752  
1481  
1258  
1072  
1703  
1437  
1219  
1037  
917.7  
886.1  
949.3  
Please read Important notes and  
Cautions and warnings at the end of this document.  
Page 11 of 17  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
B57862S0103F040  
R/T No.  
8016  
T (°C)  
B25/100 = 3988 K, R25 = 10000 , TR = 25 °C, RR/RR = ± 1%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
95.0  
788.5  
760.2  
816.9  
3.6  
3.7  
3.9  
4.0  
4.2  
1.2  
1.3  
1.4  
1.4  
1.5  
3.0  
2.9  
2.9  
2.8  
2.7  
100.0  
105.0  
110.0  
115.0  
680.0  
588.6  
511.2  
445.4  
654.6  
565.8  
490.7  
426.9  
705.4  
611.4  
531.7  
463.9  
120.0  
125.0  
130.0  
135.0  
140.0  
389.3  
341.7  
300.9  
265.4  
234.8  
372.6  
326.6  
287.3  
253.1  
223.6  
406.0  
356.8  
314.5  
277.8  
246.0  
4.3  
4.4  
4.5  
4.7  
4.8  
1.6  
1.7  
1.8  
1.9  
2.0  
2.7  
2.6  
2.5  
2.5  
2.4  
145.0  
150.0  
155.0  
208.3  
185.3  
165.3  
198.1  
176.0  
156.9  
218.5  
194.6  
173.8  
4.9  
5.0  
5.1  
2.1  
2.2  
2.3  
2.4  
2.3  
2.3  
B57862S0103H040  
R/T No.  
T (°C)  
8016  
B25/100 = 3988 K, R25 = 10000 , TR = 25 °C, RR/RR = ± 3%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
55.0  
8.0  
7.5  
7.2  
6.8  
6.4  
1.1  
1.1  
1.0  
1.0  
1.0  
7.4  
7.1  
6.9  
6.7  
6.4  
1039700  
720660  
505430  
359310  
258160  
963050  
670100  
471690  
336500  
242590  
886440  
619540  
437940  
313690  
227020  
50.0  
45.0  
40.0  
35.0  
30.0  
25.0  
20.0  
15.0  
10.0  
6.1  
5.7  
5.4  
5.1  
4.8  
1.0  
1.0  
0.9  
0.9  
0.9  
6.2  
6.0  
5.8  
5.6  
5.4  
187750  
137860  
102340  
76665  
177000  
130370  
97070  
72929  
55330  
166250  
122880  
91801  
69193  
52658  
58002  
5.0  
0.0  
5.0  
10.0  
15.0  
4.5  
4.3  
4.0  
3.8  
3.5  
0.9  
0.8  
0.8  
0.8  
0.8  
5.3  
5.1  
5.0  
4.8  
4.7  
44239  
34046  
26406  
20648  
16260  
42315  
32650  
25388  
19900  
15708  
40391  
31254  
24369  
19152  
15156  
20.0  
25.0  
30.0  
35.0  
40.0  
3.3  
3.0  
3.3  
3.5  
3.7  
0.7  
0.7  
0.8  
0.8  
0.9  
4.5  
4.4  
4.3  
4.1  
4.0  
12899  
10300  
8321  
6759  
5524  
12490  
10000  
8057  
6531  
5327  
12081  
9700  
7793  
6304  
5130  
45.0  
3.9  
1.0  
3.9  
4539  
4369  
4199  
Please read Important notes and  
Cautions and warnings at the end of this document.  
Page 12 of 17  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
B57862S0103H040  
R/T No.  
8016  
T (°C)  
B25/100 = 3988 K, R25 = 10000 , TR = 25 °C, RR/RR = ± 3%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
50.0  
4.1  
4.3  
4.5  
4.6  
1.1  
1.2  
1.2  
1.3  
3.8  
3.7  
3.6  
3.5  
3750  
3603  
2986  
2488  
2083  
3456  
2859  
2377  
1987  
55.0  
60.0  
65.0  
3114  
2599  
2180  
70.0  
75.0  
80.0  
85.0  
90.0  
4.8  
5.0  
5.1  
5.3  
5.4  
1.4  
1.5  
1.6  
1.7  
1.8  
3.4  
3.3  
3.2  
3.2  
3.1  
1836  
1555  
1323  
1129  
967.7  
1752  
1481  
1258  
1072  
1668  
1408  
1193  
1016  
917.7  
867.7  
95.0  
100.0  
105.0  
110.0  
115.0  
788.5  
680.0  
588.6  
511.2  
445.4  
744.4  
641.0  
554.0  
480.4  
418.0  
832.6  
719.0  
623.2  
542.0  
472.8  
5.6  
5.7  
5.9  
6.0  
6.2  
1.9  
2.0  
2.1  
2.2  
2.3  
3.0  
2.9  
2.9  
2.8  
2.7  
120.0  
125.0  
130.0  
135.0  
140.0  
389.3  
341.7  
300.9  
265.4  
234.8  
364.8  
319.8  
281.2  
247.8  
218.9  
413.8  
363.6  
320.6  
283.1  
250.7  
6.3  
6.4  
6.5  
6.7  
6.8  
2.4  
2.5  
2.6  
2.7  
2.8  
2.7  
2.6  
2.5  
2.5  
2.4  
145.0  
150.0  
155.0  
208.3  
185.3  
165.3  
194.0  
172.3  
153.6  
222.7  
198.3  
177.1  
6.9  
7.0  
7.1  
2.9  
3.0  
3.1  
2.4  
2.3  
2.3  
B57862S0103J040  
R/T No.  
T (°C)  
8016  
B25/100 = 3988 K, R25 = 10000 , TR = 25 °C, RR/RR = ± 5%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
55.0  
10.0  
9.5  
9.2  
8.8  
8.4  
1.3  
1.3  
1.3  
1.3  
1.3  
7.4  
7.1  
6.9  
6.7  
6.4  
1058900  
734070  
514870  
366040  
263020  
963050  
670100  
471690  
336500  
242590  
867180  
606140  
428510  
306960  
222160  
50.0  
45.0  
40.0  
35.0  
30.0  
25.0  
20.0  
15.0  
10.0  
8.1  
7.7  
7.4  
7.1  
6.8  
1.3  
1.3  
1.3  
1.3  
1.3  
6.2  
6.0  
5.8  
5.6  
5.4  
191290  
140470  
104280  
78124  
177000  
130370  
97070  
72929  
55330  
162710  
120270  
89860  
67735  
51551  
59108  
5.0  
0.0  
6.5  
6.3  
1.2  
1.2  
5.3  
5.1  
45085  
34699  
42315  
32650  
39545  
30601  
Please read Important notes and  
Cautions and warnings at the end of this document.  
Page 13 of 17  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
B57862S0103J040  
R/T No.  
8016  
T (°C)  
B25/100 = 3988 K, R25 = 10000 , TR = 25 °C, RR/RR = ± 5%  
Rnom[]  
Rmin[]  
Rmax[]  
RR/RR[±%] T[±°C]  
α (%/K)  
5.0  
10.0  
15.0  
6.0  
5.8  
5.5  
1.2  
1.2  
1.2  
5.0  
4.8  
4.7  
26914  
21046  
16574  
25388  
19900  
15708  
23861  
18754  
14842  
20.0  
25.0  
30.0  
35.0  
40.0  
5.3  
5.0  
5.3  
5.5  
5.7  
1.2  
1.1  
1.2  
1.3  
1.4  
4.5  
4.4  
4.3  
4.1  
4.0  
13149  
10500  
8482  
6889  
5630  
12490  
10000  
8057  
6531  
5327  
11831  
9500  
7632  
6173  
5024  
45.0  
50.0  
55.0  
60.0  
65.0  
5.9  
6.1  
6.3  
6.5  
6.6  
1.5  
1.6  
1.7  
1.8  
1.9  
3.9  
3.8  
3.7  
3.6  
3.5  
4626  
3822  
3174  
2649  
2221  
4369  
3603  
2986  
2488  
2083  
4111  
3384  
2799  
2327  
1945  
70.0  
75.0  
80.0  
85.0  
90.0  
6.8  
7.0  
7.1  
7.3  
7.4  
2.0  
2.1  
2.2  
2.3  
2.4  
3.4  
3.3  
3.2  
3.2  
3.1  
1871  
1585  
1348  
1151  
1752  
1481  
1258  
1072  
1633  
1378  
1168  
994.2  
849.4  
917.7  
986.0  
95.0  
100.0  
105.0  
110.0  
115.0  
788.5  
680.0  
588.6  
511.2  
445.4  
728.6  
627.4  
542.2  
470.2  
409.1  
848.4  
732.6  
635.0  
552.2  
481.7  
7.6  
7.7  
7.9  
8.0  
8.2  
2.5  
2.6  
2.8  
2.9  
3.0  
3.0  
2.9  
2.9  
2.8  
2.7  
120.0  
125.0  
130.0  
135.0  
140.0  
389.3  
341.7  
300.9  
265.4  
234.8  
357.1  
313.0  
275.2  
242.5  
214.2  
421.5  
370.4  
326.6  
288.4  
255.4  
8.3  
8.4  
8.5  
8.7  
8.8  
3.1  
3.2  
3.4  
3.5  
3.6  
2.7  
2.6  
2.5  
2.5  
2.4  
145.0  
150.0  
155.0  
208.3  
185.3  
165.3  
189.8  
168.6  
150.3  
226.8  
202.0  
180.4  
8.9  
9.0  
9.1  
3.8  
3.9  
4.0  
2.4  
2.3  
2.3  
Please read Important notes and  
Cautions and warnings at the end of this document.  
Page 14 of 17  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
Cautions and warnings  
General  
See "Important notes" at the end of this document.  
Storage  
Store thermistors only in original packaging. Do not open the package before storage.  
Storage conditions in original packaging: storage temperature 25 °C ... +45 °C, relative  
humidity 75% annual mean, maximum 95%, dew precipitation is inadmissible.  
Do not store SMDs where they are exposed to heat or direct sunlight. Otherwise, the packing  
material may be deformed or SMDs may stick together, causing problems during mounting.  
Avoid contamination of thermistors surface during storage, handling and processing.  
Avoid storage of thermistor in harmful environments like corrosive gases (SOx, Cl etc).  
After opening the factory seals, such as polyvinyl-sealed packages, use the SMDs as soon as  
possible.  
Solder thermistors after shipment from EPCOS within the time specified:  
SMDs: 12 months  
Leaded components: 24 months  
Handling  
NTC thermistors must not be dropped. Chip-offs must not be caused during handling of NTCs.  
Components must not be touched with bare hands. Gloves are recommended.  
Avoid contamination of thermistor surface during handling.  
Soldering  
Use resin-type flux or non-activated flux.  
Insufficient preheating may cause ceramic cracks.  
Rapid cooling by dipping in solvent is not recommended.  
Complete removal of flux is recommended.  
Mounting  
When NTC thermistors are encapsulated with sealing material or overmolded with plastic  
material, the precautions given in chapter “Mounting instructions”, “Sealing, potting and  
overmolding” must be observed.  
Electrode must not be scratched before/during/after the mounting process.  
Contacts and housings used for assembly with thermistor have to be clean before mounting.  
During operation, the thermistor’s surface temperature can be very high (ICL). Ensure that  
adjacent components are placed at a sufficient distance from the thermistor to allow for proper  
cooling ot the thermistors.  
Ensure that adjacent materials are designed for operation at temperatures comparable to the  
surface temperature of the thermistor. Be sure that surrounding parts and materials can  
withstand this temperature.  
Make sure that thermistors (ICLs) are adequately ventilated to avoid overheating.  
Avoid contamination of thermistor surface during processing.  
Please read Important notes and  
Page 15 of 17  
Cautions and warnings at the end of this document.  
Temperature measurement  
B57862  
S862  
Miniature sensors with bendable wires  
Operation  
Use thermistors only within the specified operating temperature range.  
Use thermistors only within the specified voltage and current ranges (ICLs).  
Environmental conditions must not harm the thermistors. Use thermistors only in normal  
atmospheric conditions.  
Contact of NTC thermistors with any liquids and solvents should be prevented. It must be  
ensured that no water enters the NTC thermistor (e.g. through plug terminals). For  
measurement purposes (checking the specified resistance vs. temperature), the component  
must not be immersed in water but in suitable liquids (e.g. Galden).  
Avoid dewing and condensation.  
Be sure to provide an appropriate fail-safe function to prevent secondary product damage  
caused by malfunction (e.g. use VDR for limitation of overvoltage condition).  
Please read Important notes and  
Page 16 of 17  
Cautions and warnings at the end of this document.  
Important notes  
The following applies to all products named in this publication:  
1. Some parts of this publication contain statements about the suitability of our products for  
certain areas of application. These statements are based on our knowledge of typical re-  
quirements that are often placed on our products in the areas of application concerned. We  
nevertheless expressly point out that such statements cannot be regarded as binding  
statements about the suitability of our products for a particular customer application.  
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar  
with them than the customers themselves. For these reasons, it is always ultimately incum-  
bent on the customer to check and decide whether an EPCOS product with the properties de-  
scribed in the product specification is suitable for use in a particular customer application.  
2. We also point out that in individual cases, a malfunction of passive electronic compon-  
ents or failure before the end of their usual service life cannot be completely ruled out  
in the current state of the art, even if they are operated as specified. In customer applica-  
tions requiring a very high level of operational safety and especially in customer applications  
in which the malfunction or failure of a passive electronic component could endanger human  
life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured  
by means of suitable design of the customer application or other action taken by the customer  
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by  
third parties in the event of malfunction or failure of a passive electronic component.  
3. The warnings, cautions and product-specific notes must be observed.  
4. In order to satisfy certain technical requirements, some of the products described in this  
publication may contain substances subject to restrictions in certain jurisdictions (e.g.  
because they are classed as “hazardous”). Useful information on this will be found in our  
Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more  
detailed questions, please contact our sales offices.  
5. We constantly strive to improve our products. Consequently, the products described in this  
publication may change from time to time. The same is true of the corresponding product  
specifications. Please check therefore to what extent product descriptions and specifications  
contained in this publication are still applicable before or when you place an or-  
der.  
We also reserve the right to discontinue production and delivery of products. Con-  
sequently, we cannot guarantee that all products named in this publication will always be  
available.  
6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver-  
sion of the “General Terms of Delivery for Products and Services in the Electrical In-  
dustry” published by the German Electrical and Electronics Industry Association  
(ZVEI).  
7. The trade names EPCOS, EPCOS-JONES, Baoke, CeraDiode, CSSP, MLSC, PhaseCap,  
PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are  
trademarks registered or pending in Europe and in other countries. Further information will  
be found on the Internet at www.epcos.com/trademarks.  
Page 17 of 17  

相关型号:

B57862S0502+040

Miniature Sensors
EPCOS

B57863

temperature measurement
EPCOS

B57863-S103-F40

RESISTOR, TEMPERATURE DEPENDENT, NTC, 10000ohm, CHASSIS MOUNT, RADIAL LEADED
EPCOS

B57863-S103-G40

RESISTOR, TEMPERATURE DEPENDENT, NTC, 10000ohm, CHASSIS MOUNT, RADIAL LEADED
EPCOS

B57863-S302-F40

RESISTOR, TEMPERATURE DEPENDENT, NTC, 3000ohm, CHASSIS MOUNT, RADIAL LEADED
EPCOS

B57863-S302-G40

RESISTOR, TEMPERATURE DEPENDENT, NTC, 3000ohm, CHASSIS MOUNT, RADIAL LEADED
EPCOS

B57863-S303-F40

RESISTOR, TEMPERATURE DEPENDENT, NTC, 30000ohm, CHASSIS MOUNT, RADIAL LEADED
EPCOS

B57863-S303-G40

RESISTOR, TEMPERATURE DEPENDENT, NTC, 30000ohm, CHASSIS MOUNT, RADIAL LEADED
EPCOS

B57863-S502-F40

RESISTOR, TEMPERATURE DEPENDENT, NTC, 5000ohm, CHASSIS MOUNT, RADIAL LEADED
EPCOS

B57863-S502-G40

RESISTOR, TEMPERATURE DEPENDENT, NTC, 5000ohm, CHASSIS MOUNT, RADIAL LEADED
EPCOS

B57863S0103+040

Heating and air conditioning systems
EPCOS

B57863S0103040

NTC thermistors for temperature measurement
TDK