B32674D3106 [EPCOS]

Film Capacitors Metallized Polyester Film Capacitors (MKT); 薄膜电容器金属化聚酯膜电容器( MKT )
B32674D3106
型号: B32674D3106
厂家: EPCOS    EPCOS
描述:

Film Capacitors Metallized Polyester Film Capacitors (MKT)
薄膜电容器金属化聚酯膜电容器( MKT )

电容器 薄膜电容器
文件: 总32页 (文件大小:365K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Film Capacitors  
Metallized Polypropylene Film Capacitors (MKP)  
Series/Type:  
B32674 ... B32678  
Date:  
May 2009  
© EPCOS AG 2009. Reproduction, publication and dissemination of this publication, enclosures hereto and the  
information contained therein without EPCOS' prior express consent is prohibited.  
Metallized polypropylene film capacitors (MKP)  
B32674 ... B32678  
MKP DC link high power series  
Typical applications  
For high ripple current modules in:  
Frequency converters  
Dimensional drawings  
2-pin version  
Industrial and high-end power supplies  
Solar inverters  
Climatic  
Max. operating temperature: 105 °C (case)  
Climatic category (IEC 60068-1): 40/100/56  
Construction  
Dielectric: metallized polypropylene (MKP)  
Plastic case (UL 94 V-0)  
Epoxy resin sealing (UL 94 V-0)  
4-pin version  
Features  
Excellent self-healing properties  
Over-voltage capability  
Optimized electrical contact  
High frequency ripple current  
High reliability  
Long useful life  
Terminals  
Parallel wire leads, lead-free tinned  
2-pin and 4-pin versions  
Standard lead lengths: 6 1 mm  
Special lead lengths are available on  
request  
Dimensions in mm  
Lead  
Version  
Lead  
Type  
diameter  
d1  
spacing  
Marking  
±0.4  
Manufacturer's logo and lot number,  
date code, rated capacitance (coded),  
capacitance tolerance (code letter),  
rated DC voltage  
2-pin  
4-pin  
4-pin  
27.5  
37.5  
52.5  
0.8  
1.2  
1.2  
B32674D  
B32676G  
B32678G  
Delivery mode  
Bulk (untaped, lead length 6 1 mm)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 2 of 32  
B32674 ... B32678  
MKP DC link high power series  
Overview of available types  
Lead spacing 27.5 mm  
37.5 mm  
52.5 mm  
B32678  
8
Type  
Page  
VR (V DC)  
CR (µF)  
0.47  
0.68  
1.0  
1.5  
2.2  
3.0  
3.3  
4.0  
4.7  
5.0  
5.6  
6.0  
6.8  
7.5  
8.0  
8.2  
9.0  
10  
B32674  
4
B32676  
6
300 450 630 750 875 300 450 630 750 875 300 450 630 750 875  
12  
14  
15  
20  
22  
25  
30  
35  
40  
47  
60  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 3 of 32  
B32674  
MKP DC link high power series  
Ordering codes and packing units (lead spacing 27.5 mm)  
CR  
Max. dimensions  
w × h × l  
P1  
Ordering code  
(composition see  
below)  
IRMS,max  
70 °C  
IRMS,max  
70 °C  
ESRtyp Untaped  
70 °C  
10 kHz 20 kHz 10 kHz  
µF  
mm  
mm  
A
A
mΩ  
pcs./MOQ  
VR,85  
°
C = 300 V DC, Vop,70  
°
=
450 V DC  
C
2.2  
3.3  
4.7  
5.0  
5.6  
6.8  
8.0  
8.2  
10  
11.0 × 19.0 × 31.5  
12.5 × 21.5 × 31.5  
14.0 × 24.5 × 31.5  
15.0 × 24.5 × 31.5  
15.0 × 24.5 × 31.5  
18.0 × 27.5 × 31.5  
16.0 × 32.0 × 31.5  
18.0 × 33.0 × 31.5  
21.0 × 31.0 × 31.5  
21.0 × 31.0 × 31.5  
B32674D3225+000 7.5  
B32674D3335+000 9.0  
B32674D3475+000 11.0  
B32674D3505+000 11.0  
B32674D3565+000 11.5  
B32674D3685+000 12.5  
B32674D3805+000 13.5  
B32674D3825+000 14.0  
B32674D3106+000 15.0  
B32674D3126+000 16.0  
6.5  
8.0  
9.5  
10.0  
10.5  
11.5  
12.5  
13.0  
14.0  
15.0  
7.5  
5.3  
4.1  
4.0  
3.9  
3.7  
3.4  
3.2  
2.9  
2.5  
1280  
1120  
1040  
960  
960  
800  
880  
800  
720  
640  
12  
VR,85  
°
C = 450 V DC, Vop,70  
°
= 630 V DC  
C
1.5  
2.2  
3.3  
4.7  
5.0  
5.6  
6.0  
6.8  
7.5  
11.0 × 19.0 × 31.5  
12.5 × 21.5 × 31.5  
15.0 × 24.5 × 31.5  
18.0 × 27.5 × 31.5  
16.0 × 32.0 × 31.5  
18.0 × 33.0 × 31.5  
21.0 × 31.0 × 31.5  
22.0 × 36.5 × 31.5  
22.0 × 36.5 × 31.5  
B32674D4155+000 6.5  
B32674D4225+000 8.0  
B32674D4335+000 9.5  
B32674D4475+000 11.5  
B32674D4505+000 12.0  
B32674D4565+000 12.5  
B32674D4605+000 13.0  
B32674D4685+000 14.0  
B32674D4755+000 15.0  
6.0  
7.0  
8.5  
10.5  
11.0  
11.0  
11.5  
12.5  
13.0  
9.2  
7.8  
5.2  
5.0  
5.0  
4.4  
4.3  
4.0  
3.9  
1280  
1120  
960  
800  
880  
800  
720  
640  
640  
VR,85  
°
C = 630 V DC, Vop,70  
°
= 800 V DC  
C
1.0  
1.5  
2.2  
3.3  
4.7  
5.0  
11.0 × 19.0 × 31.5  
12.5 × 21.5 × 31.5  
15.0 × 24.5 × 31.5  
16.0 × 32.0 × 31.5  
22.0 × 36.5 × 31.5  
22.0 × 36.5 × 31.5  
B32674D6105+000 5.0  
B32674D6155+000 6.5  
B32674D6225+000 7.0  
B32674D6335+000 7.0  
B32674D6475+000 9.5  
B32674D6505+000 10.5  
4.5  
6.0  
6.0  
6.0  
9.5  
9.5  
14.4  
14.3  
8.0  
6.5  
5.8  
1280  
1120  
960  
880  
640  
5.8  
640  
MOQ = Minimum Order Quantity, consisting of 4 packing units.  
Further E series and intermediate capacitance values on request.  
Composition of ordering code  
+ = Capacitance tolerance code:  
K = ±10%  
J = ±5%  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 4 of 32  
B32674  
MKP DC link high power series  
Ordering codes and packing units (lead spacing 27.5 mm)  
CR  
Max. dimensions  
w × h × l  
P1  
Ordering code  
(composition see  
below)  
IRMS,max  
70 °C  
IRMS,max  
70 °C  
ESRtyp Untaped  
70 °C  
10 kHz 20 kHz 10 kHz  
µF  
mm  
mm  
A
A
mΩ  
pcs./MOQ  
VR,85  
°
C = 750 V DC, Vop,70  
°
= 900 V DC  
C
0.68 11.0 × 19.0 × 31.5  
B32674D1684+000 5.0  
B32674D1105+000 6.0  
B32674D1155+000 7.5  
B32674D1225+000 9.0  
B32674D1335+000 10.0  
B32674D1405+000 11.0  
4.5  
5.5  
6.0  
7.5  
9.0  
23.3  
12.4  
9.5  
6.6  
6.0  
1280  
1120  
1040  
800  
720  
640  
1.0  
1.5  
2.2  
3.3  
4.0  
12.5 × 21.5 × 31.5  
14.0 × 24.5 × 31.5  
18.0 × 27.5 × 31.5  
21.0 × 31.0 × 31.5  
22.0 × 36.5 × 31.5  
10.0  
5.6  
VR,85  
°
C = 875 V DC, Vop,70 C = 1050 V DC  
°
0.47 11.0 × 19.0 × 31.5  
0.68 11.0 × 21.0 × 31.5  
B32674D8474+000 5.0  
B32674D8684+000 6.0  
B32674D8105+000 7.5  
B32674D8155+000 7.0  
B32674D8225+000 10.0  
B32674D8305+000 11.0  
4.5  
5.5  
6.0  
6.5  
9.0  
22.9  
18.6  
13.6  
8.5  
5.1  
6.8  
1280  
1280  
1040  
800  
800  
640  
1.0  
1.5  
2.2  
3.0  
13.5 × 23.0 × 31.5  
18.0 × 27.5 × 31.5  
18.0 × 33.0 × 31.5  
22.0 × 36.5 × 31.5  
10.0  
MOQ = Minimum Order Quantity, consisting of 4 packing units.  
Further E series and intermediate capacitance values on request.  
Composition of ordering code  
+ = Capacitance tolerance code:  
K = ±10%  
J = ±5%  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 5 of 32  
B32676  
MKP DC link high power series  
Ordering codes and packing units (lead spacing 37.5 mm)  
CR  
Max. dimensions  
w × h × l  
P1  
Ordering code  
(composition see  
below)  
IRMS,max  
70 °C  
IRMS,max  
70 °C  
ESRtyp Untaped  
70 °C  
10 kHz 20 kHz 10 kHz  
µF  
mm  
mm  
A
A
mΩ  
pcs./MOQ  
VR,85  
°
C = 300 V DC, Vop,70  
°
= 450 V DC  
C
15  
20  
22  
25  
30  
35  
20.0 × 39.5 × 42.0 10.2 B32676G3156+000 15.0  
28.0 × 37.0 × 42.0 10.2 B32676G3206+000 15.5  
28.0 × 42.5 × 42.0 20.3 B32676G3226+000 16.0  
28.0 × 42.5 × 42.0 20.3 B32676G3256+000 16.5  
30.0 × 45.0 × 42.0 20.3 B32676G3306+000 17.0  
33.0 × 48.0 × 42.0 20.3 B32676G3356+000 18.0  
14.0  
14.5  
15.0  
15.5  
16.0  
17.0  
3.2  
2.7  
2.6  
2.4  
2.3  
1.5  
640  
440  
440  
440  
400  
192  
VR,85  
°
C = 450 V DC, Vop,70  
°
= 630 V DC  
C
8.2  
10  
15  
20  
25  
20.0 × 39.5 × 42.0 10.2 B32676G4825+000 11.5  
20.0 × 39.5 × 42.0 10.2 B32676G4106+000 12.5  
28.0 × 42.5 × 42.0 10.2 B32676G4156+000 14.0  
30.0 × 45.0 × 42.0 20.3 B32676G4206K000 16.0  
33.0 × 48.0 × 42.0 20.3 B32676G4256K000 18.0  
10.0  
11.0  
13.0  
15.0  
17.0  
8.8  
7.3  
5.0  
4.0  
1.5  
640  
640  
440  
400  
192  
VR,85  
°
C = 630 V DC, Vop,70  
°
= 800 V DC  
C
6.8  
7.5  
8.2  
10  
12  
14  
20.0 × 39.5 × 42.0 10.2 B32676G6685+000 10.0  
20.0 × 39.5 × 42.0 10.2 B32676G6755+000 10.0  
28.0 × 37.0 × 42.0 10.2 B32676G6825+000 10.5  
28.0 × 42.5 × 42.0 20.3 B32676G6106+000 11.0  
28.0 × 42.5 × 42.0 20.3 B32676G6126+000 11.5  
30.0 × 45.0 × 42.0 20.3 B32676G6146+000 12.0  
33.0 × 48.0 × 42.0 20.3 B32676G6156+000 15.0  
9.5  
9.5  
7.1  
6.7  
6.2  
5.7  
5.5  
3.6  
2.3  
640  
640  
440  
440  
440  
400  
192  
10.0  
10.5  
11.0  
11.5  
14.0  
15  
VR,85  
°
C = 750 V DC, Vop,70  
°
= 900 V DC  
C
4.7  
5.6  
6.8  
9.0  
10  
20.0 × 39.5 × 42.0 10.2 B32676G1475+000 11.0  
20.0 × 39.5 × 42.0 10.2 B32676G1565+000 11.5  
28.0 × 37.0 × 42.0 20.3 B32676G1685+000 12.5  
28.0 × 42.5 × 42.0 20.3 B32676G1905+000 14.0  
30.0 × 45.0 × 42.0 20.3 B32676G1106+000 15.0  
33.0 × 48.0 × 42.0 20.3 B32676G1126+000 19.5  
10.0  
10.5  
11.5  
13.0  
14.0  
19.0  
7.8  
7.1  
6.7  
6.0  
5.8  
2.7  
640  
640  
440  
440  
400  
192  
12  
MOQ = Minimum Order Quantity, consisting of 4 packing units.  
Further E series and intermediate capacitance values on request.  
Composition of ordering code  
+ = Capacitance tolerance code:  
K = ±10%  
J = ±5%  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 6 of 32  
B32676  
MKP DC link high power series  
Ordering codes and packing units (lead spacing 37.5 mm)  
CR  
Max. dimensions  
w × h × l  
P1  
Ordering code  
(composition see  
below)  
IRMS,max  
70 °C  
IRMS,max  
70 °C  
ESRtyp Untaped  
70 °C  
10 kHz 20 kHz 10 kHz  
µF  
mm  
mm  
A
A
mΩ  
pcs./MOQ  
VR,85  
°
C = 875 V DC, Vop,70 C = 1050 V DC  
°
3.3  
4.0  
4.7  
6.8  
7.5  
10  
20.0 × 39.5 × 42.0 10.2 B32676G8335+000 11.0  
20.0 × 39.5 × 42.0 10.2 B32676G8405+000 11.5  
28.0 × 37.0 × 42.0 20.3 B32676G8475+000 12.5  
28.0 × 42.5 × 42.0 20.3 B32676G8685+000 14.0  
30.0 × 45.0 × 42.0 20.3 B32676G8755+000 15.0  
33.0 × 48.0 × 42.0 20.3 B32676G8106K000 19.5  
10.0  
10.5  
11.5  
13.0  
14.0  
19.0  
11.0  
9.8  
8.6  
8.3  
8.0  
3.7  
640  
640  
440  
440  
400  
192  
MOQ = Minimum Order Quantity, consisting of 4 packing units.  
Further E series and intermediate capacitance values on request.  
Composition of ordering code  
+ = Capacitance tolerance code:  
K = ±10%  
J = ±5%  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 7 of 32  
B32678  
MKP DC link high power series  
Ordering codes and packing units (lead spacing 52.5 mm)  
CR  
Max. dimensions  
w × h × l  
P1  
Ordering code  
(composition see  
below)  
IRMS,max  
70 °C  
IRMS,max  
70 °C  
ESRtyp Untaped  
70 °C  
10 kHz 20 kHz 10 kHz  
µF  
mm  
mm  
A
A
mΩ  
pcs./MOQ  
VR,85  
°
°
C = 300 V DC, Vop,70  
°
= 450 V DC  
C
40  
47  
60  
30.0 × 45.0 × 57.5 20.3 B32678G3406+000 19.0  
35.0 × 50.0 × 57.5 20.3 B32678G3476+000 21.0  
35.0 × 50.0 × 57.5 20.3 B32678G3606K000 23.0  
18.0  
20.0  
22.0  
1.9  
1.7  
1.6  
280  
108  
108  
VR,85  
C = 450 V DC, Vop,70  
°
= 630 V DC  
C
30  
35  
40  
35.0 × 50.0 × 57.5 20.3 B32678G4306+000 19.5  
35.0 × 50.0 × 57.5 20.3 B32678G4356+000 21.0  
35.0 × 50.0 × 57.5 20.3 B32678G4406K000 22.0  
18.5  
20.0  
21.0  
2.1  
1.7  
1.5  
108  
108  
108  
VR,85  
°
°
°
C = 630 V DC, Vop,70  
°
= 800 V DC  
C
20  
25  
35.0 × 50.0 × 57.5 20.3 B32678G6206+000 17.5  
35.0 × 50.0 × 57.5 20.3 B32678G6256+000 20.0  
16.5  
19.0  
2.9  
2.6  
108  
108  
VR,85  
C = 750 V DC, Vop,70  
°
= 900 V DC  
C
15  
20  
30.0 × 45.0 × 57.5 20.3 B32678G1156K000 20.0  
35.0 × 50.0 × 57.5 20.3 B32678G1206K000 21.0  
19.5  
20.0  
3.7  
2.6  
280  
108  
VR,85  
15  
C = 875 V DC, Vop,70  
°
C = 1050 V DC  
35.0 × 50.0 × 57.5 20.3 B32678G8156K000 21.0  
20.0  
3.4  
108  
MOQ = Minimum Order Quantity, consisting of 4 packing units.  
Further E series and intermediate capacitance values on request.  
Composition of ordering code  
+ = Capacitance tolerance code:  
K = ±10%  
J = ±5%  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 8 of 32  
B32674 ... B32678  
MKP DC link high power series  
Technical data  
Reference standard: IEC 61071. All data given at T = 20 °C, unless otherwise specified.  
Max. operating temperature, Top,max +105 °C  
Operating temperature range (case)  
Upper category temperature Tmax  
Lower category temperature Tmin  
< 3.0 ESRtyp  
< 2.5 ESRtyp  
< 1.5 ESRtyp  
+100 °C  
–40 °C  
LS 27.5  
LS 37.5  
LS 52.5  
ESR (at 10 kHz)  
Insulation Resistance Rins  
given as time constant  
30 000 s  
t= CR Rins, rel. humidity 65%  
(minimum as-delivered values)  
DC test voltage between terminals (10 s) 1.5 VR  
DC test voltage terminal to case (10 s)  
Maximum peak current (A)  
2110 V AC, 50 Hz  
Damp heat test  
Limit values after damp heat test  
56 days/40 °C/93% relative humidity  
Capacitance change | C/C | 5%  
Dissipation factor change tan δ ≤ 1.5 · 10-3 (at 1 kHz)  
50% of minimum  
Insulation resistance Rins  
as-delivered values  
Reliability:  
VR (V DC)  
Failure rate λ  
1 fit (1 10-9/h) at 0.5 VR, 40 °C  
200 000 h at VR, 85 °C  
For conversion to other operating conditions and  
temperatures, refer to chapter "Quality, 2 Reliability".  
Service life tSL  
300  
450  
630  
750  
875  
Continuous operation voltage  
Vop (V DC) at 70 °C  
450  
630  
800  
900  
1050  
Continuous operation voltage  
Vop (V DC) at 85 °C  
Maximum peak voltage  
VP,max (V DC)  
300  
450  
450  
675  
630  
950  
750  
875  
1125  
1300  
For temperatures between  
85 °C and 100 °C  
1.2%/°C of derating respect Vop at 85 °C  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 9 of 32  
B32674 ... B32678  
MKP DC link high power series  
Pulse handling capability  
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal  
voltages, expressed in V/µs.  
Note:  
The values of dV/dt provided below must not be exceeded in order to avoid damaging the  
capacitor.  
dV/dt values  
Lead spacing  
Type  
VR (V DC)  
CR (µF)  
0.47  
0.68  
1.0  
1.5  
2.2  
3.0  
3.3  
4.0  
4.7  
5.0  
5.6  
6.0  
6.8  
7.5  
8.0  
8.2  
9.0  
10  
12  
14  
15  
20  
22  
25  
30  
35  
40  
47  
60  
27.5 mm  
B32674  
37.5 mm  
B32676  
52.5 mm  
B32678  
300 450 630 750 875 300 450 630 750 875 300 450 630 750 875  
dV/dt in V/µs  
150  
100  
100  
35  
35  
125 150  
100 125 150  
75 100 125 150  
40 75 100 125 150  
40  
40 75 100 125  
150  
125  
40 75 100  
40 75 100  
40 75  
85 100  
85  
75  
75  
75  
73 85 100  
73  
100  
54 73  
54 73 85 100  
85  
73 85  
73  
22 54 73  
60 70  
22 54  
22  
22 54  
50 60  
50  
22  
22  
15 35  
15  
15  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 10 of 32  
B32674 ... B32678  
MKP DC link high power series  
ESL values  
ESL  
2-pin  
4-pin  
25 nH  
17 nH  
Typical waveforms  
Restrictions:  
VR: Maximum operating peak voltage of either polarity but of a non-reversing waveform, for which  
the capacitor has been designed for continuous operation.  
AC 0.2 VR  
VP, max: Maximum permissible recurrent voltage that may appear for 2% of the period.  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 11 of 32  
B32674 ... B32678  
MKP DC link high power series  
Mounting guidelines  
1
Soldering  
Solderability of leads  
1.1  
The solderability of terminal leads is tested to IEC 60068-2-20, test Ta, method 1.  
Before a solderability test is carried out, terminals are subjected to accelerated ageing (to  
IEC 60068-2-2, test Ba: 4 h exposure to dry heat at 155 °C). Since the ageing temperature is far  
higher than the upper category temperature of the capacitors, the terminal wires should be cut off  
from the capacitor before the ageing procedure to prevent the solderability being impaired by the  
products of any capacitor decomposition that might occur.  
Solder bath temperature  
Soldering time  
235 ±5 °C  
2.0 ±0.5 s  
Immersion depth  
Evaluation criteria:  
Visual inspection  
2.0 +0/0.5 mm from capacitor body or seating plane  
Wetting of wire surface by new solder 90%, free-flowing solder  
1.2  
Resistance to soldering heat  
Resistance to soldering heat is tested to IEC 60068-2-20, test Tb, method 1A.  
Conditions:  
Series  
Solder bath temperature Soldering time  
MKT boxed (except 2.5 × 6.5 × 7.2 mm) 260 ±5 °C  
coated  
10 ±1 s  
uncoated (lead spacing > 10 mm)  
MFP  
MKP (lead spacing > 7.5 mm)  
MKT boxed (case 2.5 × 6.5 × 7.2 mm)  
5 ±1 s  
(lead spacing 7.5 mm)  
uncoated (lead spacing 10 mm)  
insulated (B32559)  
MKP  
MKT  
< 4 s  
recommended soldering  
profile for MKT uncoated  
(lead spacing 10 mm) and  
insulated (B32559)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 12 of 32  
B32674 ... B32678  
MKP DC link high power series  
Immersion depth  
Shield  
2.0 +0/0.5 mm from capacitor body or seating plane  
Heat-absorbing board, (1.5 ±0.5) mm thick, between capacitor  
body and liquid solder  
Evaluation criteria:  
Visual inspection  
No visible damage  
2% for MKT/MKP/MFP  
5% for EMI suppression capacitors  
As specified in sectional specification  
C/C0  
tan δ  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 13 of 32  
B32674 ... B32678  
MKP DC link high power series  
1.3  
General notes on soldering  
Permissible heat exposure loads on film capacitors are primarily characterized by the upper cate-  
gory temperature Tmax. Long exposure to temperatures above this type-related temperature limit  
can lead to changes in the plastic dielectric and thus change irreversibly a capacitor's electrical  
characteristics. For short exposures (as in practical soldering processes) the heat load (and thus  
the possible effects on a capacitor) will also depend on other factors like:  
Pre-heating temperature and time  
Forced cooling immediately after soldering  
Terminal characteristics:  
diameter, length, thermal resistance, special configurations (e.g. crimping)  
Height of capacitor above solder bath  
Shadowing by neighboring components  
Additional heating due to heat dissipation by neighboring components  
Use of solder-resist coatings  
The overheating associated with some of these factors can usually be reduced by suitable coun-  
termeasures. For example, if a pre-heating step cannot be avoided, an additional or reinforced  
cooling process may possibly have to be included.  
EPCOS recommends the following conditions:  
Pre-heating with a maximum temperature of 110 °C  
Temperature inside the capacitor should not exceed the following limits:  
MKP/MFP 110 °C  
MKT 160 °C  
When SMD components are used together with leaded ones, the leaded film capacitors should  
not pass into the SMD adhesive curing oven. The leaded components should be assembled af-  
ter the SMD curing step.  
Leaded film capacitors are not suitable for reflow soldering.  
Uncoated capacitors  
For uncoated MKT capacitors with lead spacings 10 mm (B32560/B32561) the following mea-  
sures are recommended:  
pre-heating to not more than 110 °C in the preheater phase  
rapid cooling after soldering  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 14 of 32  
B32674 ... B32678  
MKP DC link high power series  
2
Cleaning  
To determine whether the following solvents, often used to remove flux residues and other sub-  
stances, are suitable for the capacitors described, refer to the table below:  
Type  
Ethanol,  
isopropanol,  
n-propanol  
n-propanol-water  
mixtures,  
water with surface  
tension-reducing  
tensides (neutral)  
Solvent from  
table A (see  
next page)  
Solvent from  
table B (see  
next page)  
MKT  
(uncoated)  
Suitable  
Unsuitable  
In part suitable Unsuitable  
Suitable  
MKT, MKP, MFP  
(coated/boxed)  
Suitable  
Even when suitable solvents are used, a reversible change of the electrical characteristics may  
occur in uncoated capacitors immediately after they are washed. Thus it is always recommended  
to dry the components (e.g. 4 h at 70 °C) before they are subjected to subsequent electrical test-  
ing.  
Table A  
Manufacturers' designations for trifluoro-trichloro-ethane-based cleaning solvents (selection)  
Trifluoro-trichloro-  
ethane  
Mixtures of trifluoro-trichloro-ethane with ethanol and  
isopropanol  
Manufacturer  
Freon TF  
Freon TE 35; Freon TP 35; Freon TES  
Frigen 113 TR-E; Frigen 113 TR-P; Frigen TR-E 35  
Arklone A; Arklone L; Arklone K  
Du Pont  
Hoechst  
ICI  
Frigen 113 TR  
Arklone P  
Kaltron 113 MDR  
Flugene 113  
Kaltron 113 MDA; Kaltron 113 MDI; Kaltron 113 MDI 35 Kali-Chemie  
Flugene 113 E; Flugene 113 IPA Rhone-Progil  
Table B (worldwide banned substances)  
Manufacturers' designations for unsuitable cleaning solvents (selection)  
Mixtures of chlorinated hydrocarbons and ketones with fluorated hydrocarbons Manufacturer  
Freon TMC; Freon TA; Freon TC  
Arklone E  
Du Pont  
ICI  
Kaltron 113 MDD; Kaltron 113 MDK  
Flugene 113 CM  
Kali-Chemie  
Rhone-Progil  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 15 of 32  
B32674 ... B32678  
MKP DC link high power series  
3
Embedding of capacitors in finished assemblies  
In many applications, finished circuit assemblies are embedded in plastic resins. In this case,  
both chemical and thermal influences of the embedding ("potting") and curing processes must be  
taken into account.  
Our experience has shown that the following potting materials can be recommended: non-flexible  
epoxy resins with acid-anhydride hardeners; chemically inert, non-conducting fillers; maximum  
curing temperature of 100 °C.  
Caution:  
Consult us first if you wish to embed uncoated types!  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 16 of 32  
B32674 ... B32678  
MKP DC link high power series  
Cautions and warnings  
Do not exceed the upper category temperature (UCT).  
Do not apply any mechanical stress to the capacitor terminals.  
Avoid any compressive, tensile or flexural stress.  
Do not move the capacitor after it has been soldered to the PC board.  
Do not pick up the PC board by the soldered capacitor.  
Do not place the capacitor on a PC board whose PTH hole spacing differs from the specified  
lead spacing.  
Do not exceed the specified time or temperature limits during soldering.  
Avoid external energy inputs, such as fire or electricity.  
Avoid overload of the capacitors.  
The table below summarizes the safety instructions that must always be observed. A detailed de-  
scription can be found in the relevant sections of the chapters "General technical information" and  
"Mounting guidelines".  
Topic  
Safety information  
Reference chapter  
"General technical  
information"  
Storage conditions Make sure that capacitors are stored within the  
4.5  
specified range of time, temperature and humidity "Storage conditions"  
conditions.  
Flammability  
Avoid external energy, such as fire or electricity  
(passive flammability), avoid overload of the  
capacitors (active flammability) and consider the  
flammability of materials.  
5.3  
"Flammability"  
Resistance to  
vibration  
Do not exceed the tested ability to withstand  
vibration. The capacitors are tested to  
IEC 60068-2-6.  
5.2  
"Resistance to vibration"  
EPCOS offers film capacitors specially designed  
for operation under more severe vibration regimes  
such as those found in automotive applications.  
Consult our catalog "Film Capacitors for  
Automotive Electronics".  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 17 of 32  
B32674 ... B32678  
MKP DC link high power series  
Topic  
Safety information  
Reference chapter  
"Mounting guidelines"  
Soldering  
Cleaning  
Do not exceed the specified time or temperature 1 "Soldering"  
limits during soldering.  
Use only suitable solvents for cleaning capacitors. 2 "Cleaning"  
Embedding of  
capacitors in  
When embedding finished circuit assemblies in  
plastic resins, chemical and thermal influences  
3 "Embedding of  
capacitors in finished  
assemblies"  
finished assemblies must be taken into account.  
Caution: Consult us first, if you also wish to  
embed other uncoated component types!  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 18 of 32  
B32674 ... B32678  
MKP DC link high power series  
Symbols and terms  
Symbol  
α
English  
German  
Heat transfer coefficient  
Wärmeübergangszahl  
αC  
Temperature coefficient of capacitance Temperaturkoeffizient der Kapazität  
A
Capacitor surface area  
Kondensatoroberfläche  
Feuchtekoeffizient der Kapazität  
Kapazität  
βC  
Humidity coefficient of capacitance  
Capacitance  
C
CR  
Rated capacitance  
Nennkapazität  
C  
C/C  
Absolute capacitance change  
Relative capacitance change (relative  
deviation of actual value)  
Absolute Kapazitätsänderung  
Relative Kapazitätsänderung (relative  
Abweichung vom Ist-Wert)  
C/CR  
Capacitance tolerance (relative deviation Kapazitätstoleranz (relative Abweichung  
from rated capacitance)  
Time differential  
vom Nennwert)  
dt  
Differentielle Zeit  
t  
Time interval  
Zeitintervall  
T  
Absolute temperature change  
(self-heating)  
Absolute Temperaturänderung  
(Selbsterwärmung)  
tan δ  
V  
Absolute change of dissipation factor  
Absolute voltage change  
Absolute Änderung des Verlustfaktors  
Absolute Spannungsänderung  
dV/dt  
Time differential of voltage function (rate Differentielle Spannungsänderung  
of voltage rise)  
(Spannungsflankensteilheit)  
Spannungsänderung pro Zeitintervall  
Aktivierungsenergie zur Diffusion  
Eigeninduktivität  
V/t  
E
Voltage change per time interval  
Activation energy for diffusion  
Self-inductance  
ESL  
ESR  
f
Equivalent series resistance  
Frequency  
Ersatz-Serienwiderstand  
Frequenz  
f1  
Frequency limit for reducing permissible Grenzfrequenz für thermisch bedingte  
AC voltage due to thermal limits  
Reduzierung der zulässigen  
Wechselspannung  
f2  
Frequency limit for reducing permissible Grenzfrequenz für strombedingte  
AC voltage due to current limit  
Reduzierung der zulässigen  
Wechselspannung  
fr  
Resonant frequency  
Resonanzfrequenz  
FD  
Thermal acceleration factor for diffusion Therm. Beschleunigungsfaktor zur  
Diffusion  
FT  
i
Derating factor  
Deratingfaktor  
Current (peak)  
Stromspitze  
IC  
Category current (max. continuous  
current)  
Kategoriestrom (max. Dauerstrom)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 19 of 32  
B32674 ... B32678  
MKP DC link high power series  
Symbol  
IRMS  
English  
German  
(Sinusoidal) alternating current,  
root-mean-square value  
Capacitance drift  
(Sinusförmiger) Wechselstrom  
iz  
Inkonstanz der Kapazität  
Impulskennwert  
k0  
LS  
λ
Pulse characteristic  
Series inductance  
Serieninduktivität  
Failure rate  
Ausfallrate  
λ0  
Constant failure rate during useful  
service life  
Konstante Ausfallrate in der  
Nutzungsphase  
λtest  
Pdiss  
Pgen  
Q
Failure rate, determined by tests  
Dissipated power  
Experimentell ermittelte Ausfallrate  
Abgegebene Verlustleistung  
Erzeugte Verlustleistung  
Wärmeenergie  
Generated power  
Heat energy  
ρ
Density of water vapor in air  
Universal molar constant for gases  
Ohmic resistance of discharge circuit  
Dichte von Wasserdampf in Luft  
Allg. Molarkonstante für Gas  
Ohmscher Widerstand des  
Entladekreises  
R
R
Ri  
Internal resistance  
Insulation resistance  
Parallel resistance  
Series resistance  
severity (humidity test)  
Time  
Innenwiderstand  
Rins  
RP  
RS  
S
Isolationswiderstand  
Parallelwiderstand  
Serienwiderstand  
Schärfegrad (Feuchtetest)  
Zeit  
t
T
Temperature  
Temperatur  
τ
Time constant  
Zeitkonstante  
tan δ  
tan δD  
Dissipation factor  
Dielectric component of dissipation  
factor  
Verlustfaktor  
Dielektrischer Anteil des Verlustfaktors  
tan δP  
tan δS  
TA  
Parallel component of dissipation factor Parallelanteil des Verlfustfaktors  
Series component of dissipation factor  
Ambient temperature  
Serienanteil des Verlustfaktors  
Umgebungstemperatur  
Tmax  
Tmin  
Upper category temperature  
Lower category temperature  
Obere Kategorietemperatur  
Untere Kategorietemperatur  
tOL  
Operating life at operating temperature Betriebszeit bei Betriebstemperatur und  
and voltage  
-spannung  
Top  
TR  
Operating temperature  
Rated temperature  
Reference temperature  
Reference service life  
AC voltage  
Beriebstemperatur  
Nenntemperatur  
Referenztemperatur  
Referenz-Lebensdauer  
Wechselspannung  
Tref  
tSL  
VAC  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 20 of 32  
B32674 ... B32678  
MKP DC link high power series  
Symbol  
VC  
English  
German  
Category voltage  
Category AC voltage  
Kategoriespannung  
(Sinusförmige)  
VC,RMS  
Kategorie-Wechselspannung  
Teilentlade-Einsatzspannung  
Ladespannung  
VCD  
Vch  
VDC  
VFB  
Vi  
Corona-discharge onset voltage  
Charging voltage  
DC voltage  
Gleichspannung  
Fly-back capacitor voltage  
Input voltage  
Spannung (Flyback)  
Eingangsspannung  
Ausgangssspannung  
Betriebsspannung  
Vo  
Output voltage  
Vop  
Vp  
Operating voltage  
Peak pulse voltage  
Peak-to-peak voltage Impedance  
Rated voltage  
Impuls-Spitzenspannung  
Spannungshub  
Vpp  
VR  
Nennspannung  
Amplitude of rated AC voltage  
Amplitude der Nenn-Wechselspannung  
R
VRMS  
(Sinusoidal) alternating voltage,  
root-mean-square value  
S-correction voltage  
(Sinusförmige) Wechselspannung  
VSC  
Vsn  
Spannung bei Anwendung "S-correction"  
Spannung bei Anwendung  
"Beschaltung"  
Snubber capacitor voltage  
Z
Impedance  
Scheinwiderstand  
Lead spacing  
Rastermaß  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 21 of 32  
B32674 ... B32678  
MKP DC link high power series  
Mounting guidelines  
1
Soldering  
Solderability of leads  
1.1  
The solderability of terminal leads is tested to IEC 60068-2-20, test Ta, method 1.  
Before a solderability test is carried out, terminals are subjected to accelerated ageing (to  
IEC 60068-2-2, test Ba: 4 h exposure to dry heat at 155 °C). Since the ageing temperature is far  
higher than the upper category temperature of the capacitors, the terminal wires should be cut off  
from the capacitor before the ageing procedure to prevent the solderability being impaired by the  
products of any capacitor decomposition that might occur.  
Solder bath temperature  
Soldering time  
235 ±5 °C  
2.0 ±0.5 s  
Immersion depth  
Evaluation criteria:  
Visual inspection  
2.0 +0/0.5 mm from capacitor body or seating plane  
Wetting of wire surface by new solder 90%, free-flowing solder  
1.2  
Resistance to soldering heat  
Resistance to soldering heat is tested to IEC 60068-2-20, test Tb, method 1A.  
Conditions:  
Series  
Solder bath temperature Soldering time  
MKT boxed (except 2.5 × 6.5 × 7.2 mm) 260 ±5 °C  
coated  
10 ±1 s  
uncoated (lead spacing > 10 mm)  
MFP  
MKP (lead spacing > 7.5 mm)  
MKT boxed (case 2.5 × 6.5 × 7.2 mm)  
5 ±1 s  
(lead spacing 7.5 mm)  
uncoated (lead spacing 10 mm)  
insulated (B32559)  
MKP  
MKT  
< 4 s  
recommended soldering  
profile for MKT uncoated  
(lead spacing 10 mm) and  
insulated (B32559)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 22 of 32  
B32674 ... B32678  
MKP DC link high power series  
Immersion depth  
Shield  
2.0 +0/0.5 mm from capacitor body or seating plane  
Heat-absorbing board, (1.5 ±0.5) mm thick, between capacitor  
body and liquid solder  
Evaluation criteria:  
Visual inspection  
No visible damage  
2% for MKT/MKP/MFP  
5% for EMI suppression capacitors  
As specified in sectional specification  
C/C0  
tan δ  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 23 of 32  
B32674 ... B32678  
MKP DC link high power series  
1.3  
General notes on soldering  
Permissible heat exposure loads on film capacitors are primarily characterized by the upper cate-  
gory temperature Tmax. Long exposure to temperatures above this type-related temperature limit  
can lead to changes in the plastic dielectric and thus change irreversibly a capacitor's electrical  
characteristics. For short exposures (as in practical soldering processes) the heat load (and thus  
the possible effects on a capacitor) will also depend on other factors like:  
Pre-heating temperature and time  
Forced cooling immediately after soldering  
Terminal characteristics:  
diameter, length, thermal resistance, special configurations (e.g. crimping)  
Height of capacitor above solder bath  
Shadowing by neighboring components  
Additional heating due to heat dissipation by neighboring components  
Use of solder-resist coatings  
The overheating associated with some of these factors can usually be reduced by suitable coun-  
termeasures. For example, if a pre-heating step cannot be avoided, an additional or reinforced  
cooling process may possibly have to be included.  
EPCOS recommends the following conditions:  
Pre-heating with a maximum temperature of 110 °C  
Temperature inside the capacitor should not exceed the following limits:  
MKP/MFP 110 °C  
MKT 160 °C  
When SMD components are used together with leaded ones, the leaded film capacitors should  
not pass into the SMD adhesive curing oven. The leaded components should be assembled af-  
ter the SMD curing step.  
Leaded film capacitors are not suitable for reflow soldering.  
Uncoated capacitors  
For uncoated MKT capacitors with lead spacings 10 mm (B32560/B32561) the following mea-  
sures are recommended:  
pre-heating to not more than 110 °C in the preheater phase  
rapid cooling after soldering  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 24 of 32  
B32674 ... B32678  
MKP DC link high power series  
2
Cleaning  
To determine whether the following solvents, often used to remove flux residues and other sub-  
stances, are suitable for the capacitors described, refer to the table below:  
Type  
Ethanol,  
isopropanol,  
n-propanol  
n-propanol-water  
mixtures,  
water with surface  
tension-reducing  
tensides (neutral)  
Solvent from  
table A (see  
next page)  
Solvent from  
table B (see  
next page)  
MKT  
(uncoated)  
Suitable  
Unsuitable  
In part suitable Unsuitable  
Suitable  
MKT, MKP, MFP  
(coated/boxed)  
Suitable  
Even when suitable solvents are used, a reversible change of the electrical characteristics may  
occur in uncoated capacitors immediately after they are washed. Thus it is always recommended  
to dry the components (e.g. 4 h at 70 °C) before they are subjected to subsequent electrical test-  
ing.  
Table A  
Manufacturers' designations for trifluoro-trichloro-ethane-based cleaning solvents (selection)  
Trifluoro-trichloro-  
ethane  
Mixtures of trifluoro-trichloro-ethane with ethanol and  
isopropanol  
Manufacturer  
Freon TF  
Freon TE 35; Freon TP 35; Freon TES  
Frigen 113 TR-E; Frigen 113 TR-P; Frigen TR-E 35  
Arklone A; Arklone L; Arklone K  
Du Pont  
Hoechst  
ICI  
Frigen 113 TR  
Arklone P  
Kaltron 113 MDR  
Flugene 113  
Kaltron 113 MDA; Kaltron 113 MDI; Kaltron 113 MDI 35 Kali-Chemie  
Flugene 113 E; Flugene 113 IPA Rhone-Progil  
Table B (worldwide banned substances)  
Manufacturers' designations for unsuitable cleaning solvents (selection)  
Mixtures of chlorinated hydrocarbons and ketones with fluorated hydrocarbons Manufacturer  
Freon TMC; Freon TA; Freon TC  
Arklone E  
Du Pont  
ICI  
Kaltron 113 MDD; Kaltron 113 MDK  
Flugene 113 CM  
Kali-Chemie  
Rhone-Progil  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 25 of 32  
B32674 ... B32678  
MKP DC link high power series  
3
Embedding of capacitors in finished assemblies  
In many applications, finished circuit assemblies are embedded in plastic resins. In this case,  
both chemical and thermal influences of the embedding ("potting") and curing processes must be  
taken into account.  
Our experience has shown that the following potting materials can be recommended: non-flexible  
epoxy resins with acid-anhydride hardeners; chemically inert, non-conducting fillers; maximum  
curing temperature of 100 °C.  
Caution:  
Consult us first if you wish to embed uncoated types!  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 26 of 32  
B32674 ... B32678  
MKP DC link high power series  
Cautions and warnings  
Do not exceed the upper category temperature (UCT).  
Do not apply any mechanical stress to the capacitor terminals.  
Avoid any compressive, tensile or flexural stress.  
Do not move the capacitor after it has been soldered to the PC board.  
Do not pick up the PC board by the soldered capacitor.  
Do not place the capacitor on a PC board whose PTH hole spacing differs from the specified  
lead spacing.  
Do not exceed the specified time or temperature limits during soldering.  
Avoid external energy inputs, such as fire or electricity.  
Avoid overload of the capacitors.  
The table below summarizes the safety instructions that must always be observed. A detailed de-  
scription can be found in the relevant sections of the chapters "General technical information" and  
"Mounting guidelines".  
Topic  
Safety information  
Reference chapter  
"General technical  
information"  
Storage conditions Make sure that capacitors are stored within the  
4.5  
specified range of time, temperature and humidity "Storage conditions"  
conditions.  
Flammability  
Avoid external energy, such as fire or electricity  
(passive flammability), avoid overload of the  
capacitors (active flammability) and consider the  
flammability of materials.  
5.3  
"Flammability"  
Resistance to  
vibration  
Do not exceed the tested ability to withstand  
vibration. The capacitors are tested to  
IEC 60068-2-6.  
5.2  
"Resistance to vibration"  
EPCOS offers film capacitors specially designed  
for operation under more severe vibration regimes  
such as those found in automotive applications.  
Consult our catalog "Film Capacitors for  
Automotive Electronics".  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 27 of 32  
B32674 ... B32678  
MKP DC link high power series  
Topic  
Safety information  
Reference chapter  
"Mounting guidelines"  
Soldering  
Cleaning  
Do not exceed the specified time or temperature 1 "Soldering"  
limits during soldering.  
Use only suitable solvents for cleaning capacitors. 2 "Cleaning"  
Embedding of  
capacitors in  
When embedding finished circuit assemblies in  
plastic resins, chemical and thermal influences  
3 "Embedding of  
capacitors in finished  
assemblies"  
finished assemblies must be taken into account.  
Caution: Consult us first, if you also wish to  
embed other uncoated component types!  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 28 of 32  
B32674 ... B32678  
MKP DC link high power series  
Symbols and terms  
Symbol  
α
English  
German  
Heat transfer coefficient  
Wärmeübergangszahl  
αC  
Temperature coefficient of capacitance Temperaturkoeffizient der Kapazität  
A
Capacitor surface area  
Kondensatoroberfläche  
Feuchtekoeffizient der Kapazität  
Kapazität  
βC  
Humidity coefficient of capacitance  
Capacitance  
C
CR  
Rated capacitance  
Nennkapazität  
C  
C/C  
Absolute capacitance change  
Relative capacitance change (relative  
deviation of actual value)  
Absolute Kapazitätsänderung  
Relative Kapazitätsänderung (relative  
Abweichung vom Ist-Wert)  
C/CR  
Capacitance tolerance (relative deviation Kapazitätstoleranz (relative Abweichung  
from rated capacitance)  
Time differential  
vom Nennwert)  
dt  
Differentielle Zeit  
t  
Time interval  
Zeitintervall  
T  
Absolute temperature change  
(self-heating)  
Absolute Temperaturänderung  
(Selbsterwärmung)  
tan δ  
V  
Absolute change of dissipation factor  
Absolute voltage change  
Absolute Änderung des Verlustfaktors  
Absolute Spannungsänderung  
dV/dt  
Time differential of voltage function (rate Differentielle Spannungsänderung  
of voltage rise)  
(Spannungsflankensteilheit)  
Spannungsänderung pro Zeitintervall  
Aktivierungsenergie zur Diffusion  
Eigeninduktivität  
V/t  
E
Voltage change per time interval  
Activation energy for diffusion  
Self-inductance  
ESL  
ESR  
f
Equivalent series resistance  
Frequency  
Ersatz-Serienwiderstand  
Frequenz  
f1  
Frequency limit for reducing permissible Grenzfrequenz für thermisch bedingte  
AC voltage due to thermal limits  
Reduzierung der zulässigen  
Wechselspannung  
f2  
Frequency limit for reducing permissible Grenzfrequenz für strombedingte  
AC voltage due to current limit  
Reduzierung der zulässigen  
Wechselspannung  
fr  
Resonant frequency  
Resonanzfrequenz  
FD  
Thermal acceleration factor for diffusion Therm. Beschleunigungsfaktor zur  
Diffusion  
FT  
i
Derating factor  
Deratingfaktor  
Current (peak)  
Stromspitze  
IC  
Category current (max. continuous  
current)  
Kategoriestrom (max. Dauerstrom)  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 29 of 32  
B32674 ... B32678  
MKP DC link high power series  
Symbol  
IRMS  
English  
German  
(Sinusoidal) alternating current,  
root-mean-square value  
Capacitance drift  
(Sinusförmiger) Wechselstrom  
iz  
Inkonstanz der Kapazität  
Impulskennwert  
k0  
LS  
λ
Pulse characteristic  
Series inductance  
Serieninduktivität  
Failure rate  
Ausfallrate  
λ0  
Constant failure rate during useful  
service life  
Konstante Ausfallrate in der  
Nutzungsphase  
λtest  
Pdiss  
Pgen  
Q
Failure rate, determined by tests  
Dissipated power  
Experimentell ermittelte Ausfallrate  
Abgegebene Verlustleistung  
Erzeugte Verlustleistung  
Wärmeenergie  
Generated power  
Heat energy  
ρ
Density of water vapor in air  
Universal molar constant for gases  
Ohmic resistance of discharge circuit  
Dichte von Wasserdampf in Luft  
Allg. Molarkonstante für Gas  
Ohmscher Widerstand des  
Entladekreises  
R
R
Ri  
Internal resistance  
Insulation resistance  
Parallel resistance  
Series resistance  
severity (humidity test)  
Time  
Innenwiderstand  
Rins  
RP  
RS  
S
Isolationswiderstand  
Parallelwiderstand  
Serienwiderstand  
Schärfegrad (Feuchtetest)  
Zeit  
t
T
Temperature  
Temperatur  
τ
Time constant  
Zeitkonstante  
tan δ  
tan δD  
Dissipation factor  
Dielectric component of dissipation  
factor  
Verlustfaktor  
Dielektrischer Anteil des Verlustfaktors  
tan δP  
tan δS  
TA  
Parallel component of dissipation factor Parallelanteil des Verlfustfaktors  
Series component of dissipation factor  
Ambient temperature  
Serienanteil des Verlustfaktors  
Umgebungstemperatur  
Tmax  
Tmin  
Upper category temperature  
Lower category temperature  
Obere Kategorietemperatur  
Untere Kategorietemperatur  
tOL  
Operating life at operating temperature Betriebszeit bei Betriebstemperatur und  
and voltage  
-spannung  
Top  
TR  
Operating temperature  
Rated temperature  
Reference temperature  
Reference service life  
AC voltage  
Beriebstemperatur  
Nenntemperatur  
Referenztemperatur  
Referenz-Lebensdauer  
Wechselspannung  
Tref  
tSL  
VAC  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 30 of 32  
B32674 ... B32678  
MKP DC link high power series  
Symbol  
VC  
English  
German  
Category voltage  
Category AC voltage  
Kategoriespannung  
(Sinusförmige)  
VC,RMS  
Kategorie-Wechselspannung  
Teilentlade-Einsatzspannung  
Ladespannung  
VCD  
Vch  
VDC  
VFB  
Vi  
Corona-discharge onset voltage  
Charging voltage  
DC voltage  
Gleichspannung  
Fly-back capacitor voltage  
Input voltage  
Spannung (Flyback)  
Eingangsspannung  
Ausgangssspannung  
Betriebsspannung  
Vo  
Output voltage  
Vop  
Vp  
Operating voltage  
Peak pulse voltage  
Peak-to-peak voltage Impedance  
Rated voltage  
Impuls-Spitzenspannung  
Spannungshub  
Vpp  
VR  
Nennspannung  
Amplitude of rated AC voltage  
Amplitude der Nenn-Wechselspannung  
R
VRMS  
(Sinusoidal) alternating voltage,  
root-mean-square value  
S-correction voltage  
(Sinusförmige) Wechselspannung  
VSC  
Vsn  
Spannung bei Anwendung "S-correction"  
Spannung bei Anwendung  
"Beschaltung"  
Snubber capacitor voltage  
Z
Impedance  
Scheinwiderstand  
Lead spacing  
Rastermaß  
Please read Cautions and warnings and  
Important notes at the end of this document.  
Page 31 of 32  
Important notes  
The following applies to all products named in this publication:  
1. Some parts of this publication contain statements about the suitability of our products for  
certain areas of application. These statements are based on our knowledge of typical re-  
quirements that are often placed on our products in the areas of application concerned. We  
nevertheless expressly point out that such statements cannot be regarded as binding  
statements about the suitability of our products for a particular customer application.  
As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar  
with them than the customers themselves. For these reasons, it is always ultimately incum-  
bent on the customer to check and decide whether an EPCOS product with the properties de-  
scribed in the product specification is suitable for use in a particular customer application.  
2. We also point out that in individual cases, a malfunction of electronic components or  
failure before the end of their usual service life cannot be completely ruled out in the  
current state of the art, even if they are operated as specified. In customer applications  
requiring a very high level of operational safety and especially in customer applications in  
which the malfunction or failure of an electronic component could endanger human life or  
health (e.g. in accident prevention or lifesaving systems), it must therefore be ensured by  
means of suitable design of the customer application or other action taken by the customer  
(e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by  
third parties in the event of malfunction or failure of an electronic component.  
3. The warnings, cautions and product-specific notes must be observed.  
4. In order to satisfy certain technical requirements, some of the products described in this  
publication may contain substances subject to restrictions in certain jurisdictions (e.g.  
because they are classed as hazardous). Useful information on this will be found in our Ma-  
terial Data Sheets on the Internet (www.epcos.com/material). Should you have any more de-  
tailed questions, please contact our sales offices.  
5. We constantly strive to improve our products. Consequently, the products described in this  
publication may change from time to time. The same is true of the corresponding product  
specifications. Please check therefore to what extent product descriptions and specifications  
contained in this publication are still applicable before or when you place an order. We also  
reserve the right to discontinue production and delivery of products. Consequently, we  
cannot guarantee that all products named in this publication will always be available. The  
aforementioned does not apply in the case of individual agreements deviating from the fore-  
going for customer-specific products.  
6. Unless otherwise agreed in individual contracts, all orders are subject to the current ver-  
sion of the "General Terms of Delivery for Products and Services in the Electrical In-  
dustry" published by the German Electrical and Electronics Industry Association  
(ZVEI).  
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSMP, CSSP, CTVS, DSSP,  
MiniBlue, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseCube, PhaseMod, SIFERRIT,  
SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse,  
WindCap are trademarks registered or pending in Europe and in other countries. Further  
information will be found on the Internet at www.epcos.com/trademarks.  
Page 32 of 32  

相关型号:

B32674D3106+000

Metallized Polypropylene Film Capacitors (MKP)
EPCOS

B32674D3106J

CAPACITOR, METALLIZED FILM, POLYPROPYLENE, 300V, 10uF, THROUGH HOLE MOUNT, ROHS COMPLIANT
EPCOS

B32674D3106K000

CAPACITOR, METALLIZED FILM, POLYPROPYLENE, 450V, 10uF, THROUGH HOLE MOUNT, RADIAL LEADED, ROHS COMPLIANT
EPCOS

B32674D3126

Film Capacitors Metallized Polyester Film Capacitors (MKT)
EPCOS

B32674D3126+000

Metallized Polypropylene Film Capacitors (MKP)
EPCOS

B32674D3126J

Film Capacitor, Polypropylene, 300V, 5% +Tol, 5% -Tol, 12uF, Through Hole Mount, ROHS COMPLIANT
EPCOS

B32674D3225

Film Capacitors Metallized Polyester Film Capacitors (MKT)
EPCOS

B32674D3225+000

Metallized Polypropylene Film Capacitors (MKP)
EPCOS

B32674D3225J

Film Capacitor, Polypropylene, 300V, 5% +Tol, 5% -Tol, 2.2uF, Through Hole Mount, ROHS COMPLIANT
EPCOS

B32674D3225K

Film Capacitor, Polypropylene, 300V, 10% +Tol, 10% -Tol, 2.2uF, Through Hole Mount, ROHS COMPLIANT
EPCOS

B32674D3335

Film Capacitors Metallized Polyester Film Capacitors (MKT)
EPCOS

B32674D3335+000

Metallized Polypropylene Film Capacitors (MKP)
EPCOS