B25836B8996A305 [EPCOS]

Film capacitors - Power Factor Correction; 薄膜电容器 - 功率因数校正
B25836B8996A305
型号: B25836B8996A305
厂家: EPCOS    EPCOS
描述:

Film capacitors - Power Factor Correction
薄膜电容器 - 功率因数校正

电容器 薄膜电容器 功率因数校正
文件: 总9页 (文件大小:170K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Film capacitors – Power Factor Correction  
MKV capacitors  
Series/Type:  
MKV800-D-20-02  
Ordering code:  
B25836B8996A305  
Date:  
Version:  
September 2008  
2
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the  
table and then change the color to "white". This ensures that the table disappears (invisible) for the customer PDF.  
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!  
Identification/Classification 1  
(header 1 + top left bar):  
Film capacitors – Power Factor Correction  
Identification/Classification 2  
MKV capacitors  
(header 2 + bottom left header bar):  
Ordering code: (top right header bar)  
Series/Type: (top right header bar)  
B25836B8996A305  
MKV800-D-20-02  
Preliminary data  
Preliminary data (optional):  
(if necessary)  
Department:  
Date:  
FK PC OH RD  
September 2008  
2
Version:  
© EPCOS AG 2008. Reproduction, publication and dissemination of this publication, enclosures hereto and the information  
contained therein without EPCOS' prior express consent is prohibited  
Film capacitors – Power Factor Correction  
MKV capacitors  
B25836B8996A305  
MKV800-D-20-02  
Preliminary data  
Construction  
„ Dielectric: Polypropylene film with paper  
as electrode carrier  
„ Oil impregnated  
„ Extruded round aluminium can with stud  
„ Discharge resistors included  
„ Double safety system  
Features  
„ Three phase, delta connected  
„ Self-healing technology  
„ Naturally air cooled (or forced air cooling)  
„ Indoor mounting  
Typical applications  
„ For Power Factor Correction  
Terminals  
„ SIGUT terminals  
Mounting  
„ Threaded stud at bottom of can  
(max. torque = 10 Nm for M12)  
Technical data and specifications  
Characteristics  
Rated capacitance CR  
Tolerance  
MKV800-D-20-02  
3 × 33.2 µF  
–5/+10%  
Connection  
D (Delta)  
Rated voltage VR  
Rated frequency fR  
Output  
800 V AC  
50 Hz  
20 kvar  
15 A  
60 Hz  
24 kvar  
18 A  
Rated current IR  
tan δ (dielectric)  
0.2 W/kvar  
FK PC OH RD  
September 2008  
Please read Cautions and warnings and  
Page 2 of 9  
Important notes at the end of this document.  
Film capacitors – Power Factor Correction  
MKV capacitors  
B25836B8996A305  
MKV800-D-20-02  
Preliminary data  
Maximum ratings  
Vmax (up to 8 h daily) 880 V AC  
Vmax (up to 1 min)  
1040 V AC  
Imax  
IS  
3 x 55 A (TA = 60 °C, VR)  
15 kA  
Test data  
VTT  
1720 V AC/50 Hz during 10 s  
4000 V AC/50 Hz during 10 s  
0.3 W/kvar (total)  
VTC  
tan δ (50 Hz)*  
*without discharge resistors  
Climatic category  
Tmin  
–40 ºC  
Tmax  
+70 ºC  
Humidity Hrel  
Maximum altitude  
max. 95%  
4000 m  
Mean life expectancy  
tLD  
up to 300 000 h at temperature class -40/D  
max. 20 000 switchings per year according to IEC 60831-1+/2  
max. 50 000 switchings per year according to IEC 60831-1+/2 in case  
standard PFC reactors are applied  
Design data  
116.2 × 325 mm  
4.5 kg  
Dimensions (× l)  
Weight approx  
Impregnation  
Fixing  
Oil  
Threaded bolt M12  
Max. torque (Al can stud) 10 Nm  
Mounting position  
Upright/horizontal  
Terminals  
Degree of protection  
Max. torque  
Isolated terminals, IP20  
1.2 Nm  
Terminal cross section  
Maximum terminal current  
Creepage distance  
Clearance  
16 mm2 (5 AWG)  
55 A  
12.7 mm  
9.6 mm  
FK PC OH RD  
September 2008  
Please read Cautions and warnings and  
Page 3 of 9  
Important notes at the end of this document.  
Film capacitors – Power Factor Correction  
MKV capacitors  
B25836B8996A305  
MKV800-D-20-02  
Preliminary data  
Safety  
Mechanical safety  
Overpressure disconnector  
Reference standards  
IEC 60831-1/2, EN 60831-1: 1996+A1:2003 + EN 60831-1: 1996,  
VDE 560-46+47  
FK PC OH RD  
September 2008  
Please read Cautions and warnings and  
Page 4 of 9  
Important notes at the end of this document.  
Film capacitors – Power Factor Correction  
MKV capacitors  
B25836B8996A305  
MKV800-D-20-02  
Preliminary data  
FK PC OH RD  
September 2008  
Please read Cautions and warnings and  
Page 5 of 9  
Important notes at the end of this document.  
Film capacitors – Power Factor Correction  
MKV capacitors  
B25836B8996A305  
MKV800-D-20-02  
Preliminary data  
Cautions and warnings  
ƒ
In case of dents of more than 1 mm depth or any other mechanical damage, capacitors must not  
be used at all.  
ƒ
ƒ
This applies also in cases of oil leakages.  
To ensure the full functionality of the overpressure disconnector, elastic elements must not be  
hindered and a minimum space of 12 mm has to be kept above each capacitor.  
ƒ
ƒ
ƒ
Do not handle the capacitor before it is discharged.  
Resonance cases must be avoided by appropriate application design in any case.  
Handle capacitors carefully, because they may still be charged even after disconnection due to  
faulty discharging devices.  
ƒ
ƒ
Protect the capacitor properly against over current and short circuit.  
Failure to follow cautions may result, worst case, in premature failures, bursting and fire.  
Discharging  
Capacitors must be discharged to a maximum of 10% of rated voltage before they are switched in  
again. This prevents an electric impulse discharge in the application, influences the capacitor’s  
service life and protects against electric shock. The capacitor must be discharged to 75 V or less  
within 3 minutes. There must be not any switch, fuse or any other disconnecting device in the circuit  
between the power capacitor and the discharging device. MKV PFC-capacitors B-series have a pre-  
mounted ceramic discharge module; alternatively discharge reactors are available from EPCOS.  
Discharge and short circuit capacitor before handling!  
Service life expectancy  
Electrical components do not have an unlimited service life expectancy; this applies to self-healing  
capacitors too. The maximum service life expectancy may vary depending on the application the  
capacitor is used in.  
Safety  
Electrical or mechanical misapplication of capacitors may be hazardous. Personal injury or property  
damage may result from bursting of the capacitor or from expulsion of oil or melted material due to  
mechanical disruption of the capacitor.  
ƒ
ƒ
ƒ
Ensure good, effective grounding for capacitor enclosures.  
Provide means of disconnecting and insulating a faulty component/bank.  
The terminals of capacitors, connected bus bars and cables as well as other devices may also be  
energized.  
ƒ
Follow good engineering practice.  
Thermal load/over-temperature  
After installation of the capacitor it is necessary to verify that maximum hot-spot temperature is not  
exceeded at extreme service conditions.  
FK PC OH RD  
September 2008  
Please read Cautions and warnings and  
Page 6 of 9  
Important notes at the end of this document.  
Film capacitors – Power Factor Correction  
MKV capacitors  
B25836B8996A305  
MKV800-D-20-02  
Preliminary data  
Overpressure disconnector  
To ensure full functionality of an overpressure disconnector, the following must be observed:  
1. The elastic elements must not be hindered, i.e.  
- connecting lines must be flexible leads (cables),  
- there must be sufficient space (min. 12 mm) for expansion above the connections. This will  
enable a longitudinal extension of the can to secure the overpressure disconnector work.  
- folding beads must not be retained by clamps.  
2. Maximum allowed fault current of 10000 A in accordance with UL 810 standard must be assured by  
the application.  
3. Stress parameters of the capacitor must be within the IEC 60831 specification.  
Overcurrent and short circuit protection  
ƒ
ƒ
Use HRC fuses or MCCBs for short circuit protection. Short circuit protection and connecting  
cables should be selected so that 1.5 times the rated capacitor current can be permanently  
handled.  
HRC fuses do not protect a capacitor against overload  
- they are only for short circuit protection.  
ƒ
ƒ
ƒ
The HRC fuse rating should be 1.6 to 1.8 times rated capacitor current.  
Do not use HRC fuses to switch capacitors (risk of arcing).  
Use thermal magnetic over current relays for overload protection.  
Resonance cases  
Resonance cases must be avoided by appropriate application design in any case. Maximum total  
RMS capacitor current (incl. fundamental harmonic current) specified in technical data must not be  
exceeded.  
Re-switching vs. phase-opposition  
In case of voltage interruption, a sufficient discharge time has to be ensured to avoid phase-opposition and  
resulting high inrush currents.  
Vibration resistance  
The resistance to vibration of capacitors corresponds to IEC 68, part 2–6.  
Max. test conditions:  
Test duration  
6 h*  
Frequency range 1  
Displacement amplitude  
10 ... 55 Hz*  
0.75 mm*  
*corresponding to max. 98.1 m/s” or 10 g  
FK PC OH RD  
September 2008  
Please read Cautions and warnings and  
Page 7 of 9  
Important notes at the end of this document.  
Film capacitors – Power Factor Correction  
MKV capacitors  
B25836B8996A305  
MKV800-D-20-02  
Preliminary data  
These figures apply to the capacitor alone. Because the fixing and the terminals may influence the  
vibration properties, it is necessary to check stability when a capacitor is built in and exposed to  
vibration. Irrespective of this, you are advised not to locate capacitors where vibration amplitude  
reaches the maximum in strongly vibrating equipment.  
Mechanical protection  
The capacitor has to be installed in a way that mechanical damages and dents in the aluminium can  
are avoided.  
Grounding  
The threaded bottom stud of the capacitor has to be used for grounding. In case grounding is done  
via metal chassis that the capacitor is mounted to, the layer of varnish beneath the washer and nut  
should be removed. The maximum tightening torque is 10 Nm.  
Maintenance  
ƒ
ƒ
Check tightness of the connections/terminals periodically.  
Take current reading twice a year and compare with nominal current. Use a harmonic analyser or  
true effective RMS-meter.  
ƒ
ƒ
In case of current above the nominal current check your application for modifications.  
If a significant increase in the amount of non-linear loads has been detected, then a consultant  
has to be called in for a harmonic study.  
ƒ
ƒ
In case of the presence of harmonics installation of a de-tuned capacitor bank (reactors) must be  
considered.  
Check the discharge resistors/reactors and in case of doubt, check their function:  
(1) Power the capacitor up and down.  
(2) After 60 seconds the voltage between the terminals must decline to less than 50 V.  
ƒ
Check the temperature of capacitors directly after operation for a longer period, but make sure  
that the capacitors have been switched off. In case of excessive temperature of individual  
capacitors, it is recommended to replace these capacitors, as this should be an indication for loss  
factor increase, which is a sign for reaching end of life.  
Storage and operating conditions  
Do not use or store capacitors in corrosive atmosphere, especially where chloride gas, sulfide gas,  
acid, alkali, salt or the like are present. In dusty environments regular maintenance and cleaning  
especially of the terminals is required to avoid conductive path between phases and/or phases and  
ground.  
Note  
For detailed information about PFC capacitors and cautions, refer to the latest version of EPCOS PFC  
Product Profile.  
Important: Please note that the „General Safety Recommendations for Power Capacitors“ by ZVEI  
(German Electrical and Electronic Manufacturers´ Association (ZVEI) have to be observed in addition  
to the caution guidelines stated in the data sheet (Internet: www.epcos.com/pfc).  
FK PC OH RD  
September 2008  
Please read Cautions and warnings and  
Page 8 of 9  
Important notes at the end of this document.  
Important notes  
The following applies to all products named in this publication:  
1. Some parts of this publication contain statements about the suitability of our products for  
certain areas of application. These statements are based on our knowledge of typical  
requirements that are often placed on our products in the areas of application concerned. We  
nevertheless expressly point out that such statements cannot be regarded as binding  
statements about the suitability of our products for a particular customer application. As a  
rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them  
than the customers themselves. For these reasons, it is always ultimately incumbent on the  
customer to check and decide whether an EPCOS product with the properties described in the  
product specification is suitable for use in a particular customer application.  
2. We also point out that in individual cases, a malfunction of electronic components or failure  
before the end of their usual service life cannot be completely ruled out in the current state  
of the art, even if they are operated as specified. In customer applications requiring a very high  
level of operational safety and especially in customer applications in which the malfunction or  
failure of an electronic component could endanger human life or health (e.g. in accident  
prevention or life-saving systems), it must therefore be ensured by means of suitable design of the  
customer application or other action taken by the customer (e.g. installation of protective circuitry  
or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or  
failure of an electronic component.  
3. The warnings, cautions and product-specific notes must be observed.  
4. In order to satisfy certain technical requirements, some of the products described in this  
publication may contain substances subject to restrictions in certain jurisdictions (e.g.  
because they are classed as hazardous). Useful information on this will be found in our Material  
Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed  
questions, please contact our sales offices.  
5. We constantly strive to improve our products. Consequently, the products described in this  
publication may change from time to time. The same is true of the corresponding product  
specifications. Please check therefore to what extent product descriptions and specifications  
contained in this publication are still applicable before or when you place an order.  
We also reserve the right to discontinue production and delivery of products. Consequently,  
we cannot guarantee that all products named in this publication will always be available.  
The aforementioned does not apply in the case of individual agreements deviating from the  
foregoing for customer-specific products.  
6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of  
the “General Terms of Delivery for Products and Services in the Electrical Industry”  
published by the German Electrical and Electronics Industry Association (ZVEI).  
7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, CTVS, DSSP, MiniBlue, MKK,  
MLSC, MotorCap, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD,  
SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or  
pending in Europe and in other countries. Further information will be found on the Internet at  
www.epcos.com/trademarks.  
Page 9 of 9  

相关型号:

B25838

MKV AC Capacitors Damping
EPCOS

B25838-K4225-K001

CAPACITOR, METALLIZED FILM, PLASTIC, 2.2uF, STUD MOUNT
EPCOS

B25838-K4475-K009

CAPACITOR, METALLIZED FILM, PLASTIC, 4.7uF, STUD MOUNT
EPCOS

B25838-K6105-K001

CAPACITOR, METALLIZED FILM, PLASTIC, 1uF, STUD MOUNT
EPCOS

B25838-K6225-K001

CAPACITOR, METALLIZED FILM, PLASTIC, 2.2uF, STUD MOUNT
EPCOS

B25838-K6475-K009

CAPACITOR, METALLIZED FILM, PLASTIC, 4.7uF, STUD MOUNT
EPCOS

B25838-K8105-K001

CAPACITOR, METALLIZED FILM, PLASTIC, 1uF, STUD MOUNT
EPCOS

B25838-K8225-K001

CAPACITOR, METALLIZED FILM, PLASTIC, 2.2uF, STUD MOUNT
EPCOS

B25838-L4106-K004

CAPACITOR, METALLIZED FILM, PLASTIC, 10uF, STUD MOUNT
EPCOS

B25838-L4156-K004

CAPACITOR, METALLIZED FILM, PLASTIC, 15uF, STUD MOUNT
EPCOS

B25838-L4226-K004

CAPACITOR, METALLIZED FILM, PLASTIC, 22uF, STUD MOUNT
EPCOS

B25838-L4336-K004

CAPACITOR, METALLIZED FILM, PLASTIC, 33uF, STUD MOUNT
EPCOS