LPS41 [EMERSON-NETWORKPOWER]
Universal input; 通用输入![LPS41](http://pdffile.icpdf.com/pdf1/p00158/img/icpdf/LPS41_876674_icpdf.jpg)
型号: | LPS41 |
厂家: | ![]() |
描述: | Universal input |
文件: | 总3页 (文件大小:124K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
Embedded Power for
Business-Critical Continuity
Rev. 07.23.07
LPS40-M Series
1 of 3
LPS40-M Series
40 Watts
RoHS
Medical
Total Power:
40-55 Watts
Input Voltage: 85-264 VAC
120-300 VDC
# of Outputs:
Triple
Electrical Specifications
Input
Special Features
• Medical safety approvals
• Universal input
• 3" x 5" footprint
• Less than 1U high
Input range
Frequency
Inrush current
Input current
Efficiency
85-264 VAC; 120-300 VDC
47-440 Hz
<18A peak @ 115VAC; <36A peak @ 230VAC, cold start @ 25°C
1A max. (RMS) @ 115VAC
70% typical at full load
• Remote sense on main output
• Low output ripple
EMI filter
FCC Class B conducted; CISPR 22 Class A conducted;
EN55022 Class A conducted; VDE 0878 PT3 Class A conducted
<75μA @ 50/60 Hz, 264 VAC input
• Adjustable 5V output
• Overvoltage protection
• Overload protection
• 110 KHz switching frequency
• LPX40 enclosure kit available
Safety ground
leakage current
Output
Maximum power
Adjustment range
Hold-up time
40W for convection; 55W with 30CFM forced air
-5, +10% minimum
20ms @ 40W load, 115VAC nominal line
Overload protection
Short circuit protection on all outputs
Case overload protected @ 110-145% above peak rating
Overvoltage protection 5V output; 5.7 to 6.7VDC. Other outputs 10% to 25%
above nominal output
Remote sense
Compensates for 0.5 V lead drop minimum.
Will operate without remote sense connected.
Reverse connection protected.
Safety
VDE
UL
0750/EN60601-1 (IEC601)
UL2601 E182560
CSA 22.2 No.601.1
LR109492
CSA
CE Mark (LVD)
Embedded Power for
Business-Critical Continuity
Rev. 07.23.07
LPS40-M Series
2 of 3
Environmental Specifications
Operating temperature: 0° to 50°C ambient. Derate each output 2.5% per degree from
50° to 70°C, -20°C startup
Storage temperature:
-40°C to +85°C
Temperature coefficient:
0.4% per °C
Electromagnetic
susceptibility:
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Operating; non-condensing 5% to 95% RH
Humidity:
Vibration:
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell at
four major resonances 0.75G peak 5Hz to 500Hz, operational
MTBF demonstrated:
>550,000 hours at full load and 25°C ambient conditions
Ordering Information
Maximum Load
Ripple P/P
Output Minimum Maximum Load with with 30CFM
Model
1
2
3
Number Voltage Load
Convection Cooling forced Air
Peak Load Regulation (PARD)
LPS42-M 5V
LPS43-M 12V
LPS44-M 15V
LPS45-M 24V
0A
0A
0A
0A
8A
11A
12A
5A
2%
2%
2%
2%
50 mV
3.3A
2.6A
1.6A
4.5A
3.6A
2.3A
120 mV
150mV
240mV
4A
2.5A
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and
load ranges.
Power Derating Curve
55W
30 CFM Forced Air Cooling
40W
30W
Output
Power
(Watts)
27.5W
20W
Natural
Convection
Cooling
20W
10W
0W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature – °C
Embedded Power for
Business-Critical Continuity
Rev. 07.23.07
LPS40-M Series
3 of 3
Mechanical Drawing
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
5.00"
(127)
0.22"
(5.6)
4.55"
(115.6)
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
GND
M1
Remote Sense
Connector
Voltage
M2
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
SK201
_
+
Adj. Pot
3.00"
(76.2)
SK 2
1
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
2
3
4
5
6
2.55"
(64.8)
SK 1
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
N
L
3
1
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
0.15" (4)
DIA (4 places)
For global contact, visit:
www.astecpower.com
www.artesyn.com
technicalsupport@astec.com
technicalsupport@artesyn.com
1.14"
(29)
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
0.197"
(5)
Emerson Network Power.
The global leader in enabling
business-critical continuity.
Mating Connectors
Pin Assignments
Connector LPS42-M LPS43-M LPS44-M LPS45-M
AC Input:
Molex 09-50-8031 (USA)
09-91-0300 (UK)
SK1-1
SK1-3
Neutral Neutral Neutral Neutral
PINS: 08-58-0111
Line
Line
Line
Line
DC Outputs:
Molex 09-50-8061 (USA)
09-91-0600 (UK)
AC Power
SK2-1
SK2- 2
SK2- 3
SK2-4
SK2-5
SK2-6
+5V
+5V
+5V
+12V
+12V
+12V
+15V
+15V
+15V
+24V
+24V
+24V
PINS: 08-58-0111
Remote Sense: Molex 22-01-2025
PINS: 08-50-0114
Connectivity
DC Power
Common Common Common Common
Common Common Common Common
Common Common Common Common
Astec Connector Kit #70-841-006, includes all of the above
Embedded Power
1. Specifications subject to change without notice.
2. All dimensions in inches (mm), tolerance is 0.02" ( 0.5mm)
Inbound Power
SK201-1 +Sense +Sense +Sense +Sense
SK201-2 -Sense -Sense -Sense -Sense
3. Mounting holes M1 and M2 should be grounded for EMI purposes.
4. Mounting hole M1 is safety ground connection.
5. Specifications are for convection rating at factory settings at 115 VAC
input, 25°C unless otherwise stated.
Integrated Cabinet Solutions
Outside Plant
6. Warranty: 2 year
7. Weight: 0.5lbs/0.23kg
Precision Cooling
Site Monitoring and Services
EmersonNetworkPower. com
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.
相关型号:
©2020 ICPDF网 联系我们和版权申明