HSP14F1.5CS-CE
更新时间:2024-09-18 23:21:20
描述:Automation Transformers - Non-Ventilated 50 VA to 45 kVA
HSP14F1.5CS-CE 概述
Automation Transformers - Non-Ventilated 50 VA to 45 kVA
HSP14F1.5CS-CE 数据手册
通过下载HSP14F1.5CS-CE数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Dry Type Distribution Transformers
Automation Transformers - Non-Ventilated 50 VA to 45 kVA
SolaHD encapsulated transformers are rated for hazardous
locations as well as harsh industrial environments.
Encapsulation and rugged UL Listed/NEMA Type 3R
enclosures protect the transformer from dust, moisture,
and provides extra shock and vibration resistance. SolaHD
transformers fully comply with the latest edition of the
National Electrical Code for Class I, Division 2, Group A, B,
C and D locations when installed in compliance with NEC
501.100 (B).
Features
Single Phase: .05 - .250 kVA
• UL Listed/NEMA Type 3R non encapsulated enclosure
for indoor and outdoor service
E25872
E77014
• Low temperature rise, UL Class I30 ˚C insulation system,
80 ˚C temperature rise under full load
• Conduit knockouts for side entry into wiring
compartment
Certifications and Compliances
All Models
• Copper lead wire terminations
Single Phase: 0.500 - 25 kVA
Three Phase: 3 - 45 kVA
•
Listed: E25872, E77014
- UL 1561 or UL 5085-1, UL 5085-2
- CSA C22.2 No. 47 or No. 66
- RoHS Compliant
• Available as standard in Cold Rolled Steel or Painted
Stainless Steel
• UL Listed/NEMA Type 3R encapsulated enclosure for
indoor and outdoor service
Group 5, Export Models
• Electrostatically shielded for quality power on sizes
1 kVA and larger
•
Low Voltage Directive
- IEC 61558-1, IEC 61558-2-4
• UL Class 200˚C insulation system, 115˚C
temperature rise under full load
• Conduit knockouts for side entry into wiring
compartment (Type 3R versions only)
Accessories and Optional Design Styles
• Other enclosure styles available (contact Technical
Support for details):
• Copper lead wire terminations
• .500 - 45 kVA units are encapsulated with electrical
grade silica and epoxy for industrial applications
- 316 Stainless Steel
• Copper Wound designs
• UL Listed/NEMA Type 4/12 or 4X Encapsulated
Enclosures
Related Products
• Some SolaHD DC power supplies are available with
Class I, Division 2 ratings or encapsulation.
• Low temperature designs available
• cULus Listed E361435 transformers for Class I,
Division 2/Zone 2 hazardous locations are available as
custom designs.
• Surge Protective Devices
Note: Weights and dimensions may change and should not be used for construction purposes.
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© July 2020
217
Dry Type Distribution Transformers
Selection Table: Single Phase
Group 1: 240 x 480 Primary, 120/240 Secondary, 60 Hz
Catalog Number Catalog Number
Height
Approx. Ship
Weight
lbs (kg)
Width
in (mm)
Depth
in (mm)
Design
Style 1
Elec
Primary
Amps
Secondary
Amps
kVA
Group I
Group II
in (mm)
Conn 1
Rolled Steel
Stainless Steel 2
Non-Encapsulated
.050
.075
.100
.150
.250
6.00 (152.4)
6.00 (152.4)
6.00 (152.4)
8.00 (203.2)
8.00 (203.2)
4.00 (101.6)
4.00 (101.6)
4.00 (101.6)
4.00 (101.6)
4.00 (101.6)
3.00 (76.2)
3.00 (76.2)
3.00 (76.2)
4.00 (101.6)
4.00 (101.6)
3.00 (1.36)
3.00 (1.36)
4.00 (1.81)
5.00 (2.27)
8.00 (3.63)
2
2
2
2
2
15
15
15
15
15
.208/.104
.312/.156
.417/.208
.625/.313
1.04/.512
0.416/0.208
0.625/0.312
0.833/0.417
1.25/.625
HS1B50
HS1B75
HS1B100
HS1B150
HS1B250
N/A
2.08/1.04
Encapsulated
0.5
0.75
1
10.00 (254.0) 6.00 (152.4)
10.00 (254.0) 6.00 (152.4)
10.00 (254.0) 6.00 (152.4)
5.00 (127.0)
22.0 (9.98)
27.0 (12.25)
28.0 (12.70)
38.0 (17.24)
45.0 (20.42)
55.0 (24.95)
3
3
3
4
4
4
4
4
4
4
4
15
15
16
16
16
17
17
18
18
18
18
2.08/1.04
3.13/1.56
4.17/2.08
6.25/3.13
8.33/4.17
12.5/6.25
20.8/10.4
31.3/15.6
41.7/20.8
62.5/31.2
104.0/52.0
4.16/2.08
6.25/3.13
8.33/4.17
12.5/6.25
16.7/8.33
25.0/12.5
41.6/20.8
62.5/31.3
83.3./41.7
125.0/62.5
208.0/104.0
HS1F500B
HS1F750B
HS1F1BS
HSP1F500B
HSP1F750B
HSP1F1BS
HSP1F1.5AS
HSP1F2AS
HSP5F3AS
HSP5F5AS
HSP5F7.5AS
HSP5F10AS
HSP5F15BS
HSP5F25BS
5.00 (127.0)
5.00 (127.0)
1.5
2
12.00 (304.8) 10.00 (254.0) 7.00 (177.8)
12.00 (304.8) 10.00 (254.0) 7.00 (177.8)
12.00 (304.8) 10.00 (254.0) 7.00 (177.8)
HS1F1.5AS
HS1F2AS
3
HS5F3AS
5
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 131.0 (59.42)
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 155.0 (70.31)
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 166.0 (75.30)
24.00 (610.0) 17.00 (432.0) 12.50 (318.0) 375.0 (170.00)
24.00 (610.0) 17.00 (432.0) 12.50 (318.0) 400.0 (181.00)
HS5F5AS
7.5
10
15
25
HS5F7.5AS
HS5F10AS
HS5F15BS 3
HS5F25BS 3
Group 2: 600 Volt Primary, 120/240 Secondary, 60 Hz
Catalog Number
Group 1
Rolled Steel
Catalog Number
Group II
Approx. Ship
Weight
lbs (kg)
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Design
Elec
Primary
Amps
Secondary
Amps
kVA
Style 1
Conn 1
Stainless Steel 2
Non-Encapsulated
6.00 (152.4) 4.00 (101.6) 3.00 (76.2)
.100
.150
.250
4.00 (1.81)
2
2
2
21
21
21
0.167
0.25
.833/.417
1.25/.625
2.08/1.04
HS10B100
HS10B150
HS10B250
8.00 (203.2) 4.00 (101.6) 4.00 (101.6) 5.00 (2.27)
8.00 (203.2) 4.00 (101.6) 4.00 (101.6) 8.00 (3.63)
N/A
0.417
Encapsulated
.500
.750
1
10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 22.0 (9.98)
10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 23.0 (10.43)
10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 28.0 (12.70)
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 38.0 (17.24)
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 60.0 (27.22)
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 66.0 (29.94)
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 100.0 (45.36)
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 135.0 (61.23)
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 150.0 (68.04)
3
3
3
4
4
4
4
4
4
21
21
21
21
21
22
22
22
22
0.833
1.25
1.67
2.5
4.16/2.08
6.25/3.13
8.33/4.17
12.5/6.25
16.7/8.33
25.0/12.5
41.6/20.8
62.5/31.3
83.3/41.7
HS10F500B
HS10F750B
HS10F1BS
HS10F1.5AS
HS10F2AS
HS10F3AS
HS10F5AS
HS10F7.5AS
HS10F10AS
HSP10F500B
HSP10F750B
HSP10F1BS
HSP10F1.5AS
HSP10F2AS
HSP10F3AS
HSP10F5AS
HSP10F7.5AS
HSP10F10AS
1.5
2
3.33
5.0
3
5
8.3
7.5
10
12.5
16.7
Notes:
1. Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section.
2. Contact Technical Services for other enclosure types.
3. Supersedes Previous Designs, Please Contact Technical Services Regarding HS5F15AS or HSF25AS Enclosure Options.
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
218
© July 2020
Dry Type Distribution Transformers
Selection Table: Single Phase
Group 3: 120/208/240/277 Volt Primary, 120/240 Secondary, 60 Hz
Catalog Number
Group 1
Rolled Steel
Catalog Number
Group 2
Approx. Ship
Weight
lbs (kg)
Primary
Amps
@ 277 V
Design
Style 1
Elec
Conn 1
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Secondary
Amps
kVA
Stainless Steel 3
Encapsulated
1
1.5
2
10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 29.0 (13.15)
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 40.0 (18.14)
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 60.0 (27.22)
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 66.0 (29.94)
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 104.0 (47.17)
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 135.0 (61.23)
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 156.0 (70.76)
3
4
4
4
4
4
4
19
20
20
20
20
20
20
3.6
5.4
8.33/4.17
12.5/6.25
16.7/8.33
25.0/12.5
41.6/20.8
62.5/31.3
83.3/41.7
HS12F1BS
HS12F1.5AS
HS12F2AS
HS12F3AS
HS12F5AS
HS12F7.5AS
HS12F10AS
HSP12F1BS
HSP12F1.5AS
HSP12F2AS
HSP12F3AS
HSP12F5AS
HSP12F7.5AS
HSP12F10AS
7.2
3
10.8
18.0
27.1
36.1
5
7.5
10
Group 4: 190/200/208/220/380/400/415/440 Volt Primary, 110/220 Secondary, 50/60 Hz Copper wound
200/208/230/400/415/460 Volt Primary, 115/230 Secondary, 50/60 Hz Copper wound
208/240/415/480 Volt Primary, 120/240 Secondary, 60 Hz only Copper wound
Catalog Number
Group 1
Rolled Steel
Catalog Number
Group 2
Approx. Ship
Weight
lbs (kg)
Design
Style 1
Elec
Conn 1
Primary
Amps 2
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Secondary
Amps
kVA
Stainless Steel 3
Encapsulated, Copper Wound
1
1.5
2
10.00 (254.0) 6.00 (152.4) 5.00 (127.0) 34.0 (15.42)
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 40.0 (18.13)
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 60.0 (27.21)
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 73.0 (33.11)
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 100.0 (45.36)
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 140.0 (63.50)
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 175.0 (79.38)
3
4
4
4
4
4
4
23
24
24
24
24
24
24
4.5/2.3
6.8/3.4
9.1/4.5
13.6/6.8
9.1/4.5
13.6/6.8
18.2/9.1
27.3/13.6
HS14F1BS
HS14F1.5BS
HS14F2BS
HS14F3BS
HS14F5BS
HS14F7.5BS
HS14F10BS
HSP14F1BS
HSP14F1.5BS
HSP14F2BS
HSP14F3BS
HSP14F5BS
HSP14F7.5BS
HSP14F10BS
3
5
22.7/11.4 45.5/22.7
34.1/17.0 68.2/34.1
45.5/22.7 90.9/45.5
7.5
10
Group 5: Export 190/200/208/220/380/400/415/440 Volt Primary, 110/220 Secondary, 50/60 Hz Copper wound
Export 200/208/230/400/415/460 Volt Primary, 115/230 Secondary, 50/60 Hz Copper wound
Export 208/240/415/480 Volt Primary, 120/240 Secondary, 60 Hz only Copper wound
Catalog Number
Group 1
Rolled Steel
Catalog Number
Group 2
Approx. Ship
Weight
lbs (kg)
Design
Style 1
Elec
Conn 1
Primary
Amps 2
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Secondary
Amps
kVA
Stainless Steel 3
Encapsulated, Copper Wound
1
1.5
2
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 52.0 (23.6)
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 55.0 (25.0)
12.00 (304.8) 10.00 (254.0) 7.00 (177.8) 62.0 (28.1)
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 142.0 (64.4)
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 146.0 (66.2)
17.00 (431.8) 14.00 (355.6) 9.00 (228.6) 175.0 (79.4)
4
4
4
4
4
4
24
24
24
24
24
24
4.5/2.3
6.8/3.4
9.1/4.5
13.6/6.8
9.1/4.5
13.6/6.8
18.2/9.1
27.3/13.6
HS14F1CS-CE
HSP14F1CS-CE
HS14F1.5CS-CE HSP14F1.5CS-CE
HS14F2CS-CE
HS14F3CS-CE
HS14F5CS-CE
HSP14F2CS-CE
HSP14F3CS-CE
HSP14F5CS-CE
3
5
22.7/11.4 45.5/22.7
34.1/17.0 68.2/34.1
7.5
HS14F7.5CS-CE HSP14F7.5CS-CE
Notes:
1. Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section.
2. Amperage calculated at 220/440 Volts on primary. UL Listed. 240 and 480 V not available at 50 Hz.
3. Contact Technical Services for other enclosure types.
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© July 2020
219
Dry Type Distribution Transformers
Selection Tables: Three Phase
Group A: 480 Volt Δ Primary, 208Y/120 Secondary, 60 Hz
Catalog Number
Group I
Rolled Steel
Catalog Number
Group II
Approx. Ship
Weight
lbs (kg)
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Design
Style 1
Elec
Primary Secondary
kVA
Conn 1
Amps
Amps
Stainless Steel 3
3
6
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 105.0 (47.63)
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 250.0 (113.40)
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 261.0 (118.39)
30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 696.0 (315.70)
30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 844.0 (382.83)
4
4
4
4
4
4
27
27
27
27
27
27
3.6
7.2
8.3
16.6
25.0
41.7
83.4
125.0
HT1F3AS
HT1F6AS
HT1F9AS
HT1F15AS
HT1F30AS
HT1F45AS
HTP1F3AS
HTP1F6AS
HTP1F9AS
HTP1F15AS
HTP1F30AS
HTP1F45AS
9
10.8
18.1
36.1
54.2
15
30
45
Group B: 208 Volt Δ Primary, 208Y/120 Secondary, 60 Hz
Catalog Number
Group I
Rolled Steel
Catalog Number
Group II
Approx. Ship
Weight
lbs (kg)
Design
Style 1
Elec
Conn 1
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Primary
Amps
Secondary
Amps
kVA
Stainless Steel 3
3
6
9
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 97.0 (44.00)
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 256.0 (116.12)
4
4
4
26
26
26
7.2
8.3
HT3F3AS
HT3F6AS
HT3F9AS
HTP3F3AS
HTP3F6AS
HTP3F9AS
14.4
21.7
16.6
25.0
Group C: 480 Volt Δ Primary,240 Volt Δ Secondary with 120 V reduced capacity center tap, 60 Hz 2
Catalog Number
Group I
Rolled Steel
Catalog Number
Group II
Approx. Ship
Weight
lbs (kg)
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Design
Style 1
Elec
Primary
Amps
Secondary
Amps
kVA
Conn 1
Stainless Steel 3
3
6
13.00 (330.2) 16.00 (406.4) 9.00 (228.6)
13.00 (330.2) 16.00 (406.4) 9.00 (228.6)
105.0 (47.63)
150.0 (68.03)
4
4
4
4
4
4
28
28
28
28
28
28
3.6
7.2
7.2
14.4
21.7
36.1
72.2
108.3
HT5F3AS
HT5F6AS
HT5F9AS
HT5F15AS
HT5F30AS
HT5F45AS
HTP5F3AS
HTP5F6AS
HTP5F9AS
HTP5F15AS
HTP5F30AS
HTP5F45AS
9
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 250.0 (113.40)
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 305.0 (138.35)
30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 698.0 (316.61)
30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 876.0 (397.35)
10.8
18.1
36.1
54.2
15
30
45
Group D: 240 Volt Δ Primary, 208Y/120 Secondary, 60 Hz
Catalog Number
Group I
Rolled Steel
Catalog Number
Group II
Approx. Ship
Weight
lbs (kg)
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Design
Style 1
Elec
Primary
Amps
Secondary
Amps
kVA
Conn 1
Stainless Steel 3
3
6
9
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 97.0 (44.00)
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 256.0 (116.12)
4
4
4
25
25
25
7.2
8.3
HT6F3AS
HT6F6AS
HT6F9AS
HTP6F3AS
HTP6F6AS
HTP6F9AS
14.4
21.7
16.6
25.0
Notes:
1. Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section.
2. Refer to Capacity of Center Tap in Center Tap Delta Transformers at the beginning of this section.
3. Contact Technical Services for other enclosure types.
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
220
© July 2020
Dry Type Distribution Transformers
Selection Tables: Three Phase
Group E: 480 Volt Δ Primary, 380Y/220 Secondary, 60 Hz
Catalog Number
Group I
Rolled Steel
Catalog Number
Group II
Approx. Ship
Weight
lbs (kg)
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Design
Style 1
Elec
Primary Secondary
kVA
Conn 1
Amps
Amps
Stainless Steel 2
3
6
9
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 121.0 (54.88)
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 255.0 (115.7)
4
4
4
29
29
29
3.6
7.2
4.6
9.1
HT79F3AS
HT79F6AS
HT79F9AS
HTP79F3AS
HTP79F6AS
HTP79F9AS
10.8
13.6
Group F: 600 Volt Δ Primary, 208Y/120 Secondary, 60 Hz
Catalog Number
Group I
Rolled Steel
Catalog Number
Group II
Approx. Ship
Weight
lbs (kg)
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Design
Elec
Primary
Amps
Secondary
Amps
kVA
Style 1
Conn 1
Stainless Steel 2
3
6
9
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 116.0 (52.62)
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 225.0 (115.67)
4
4
4
30
30
30
2.9
5.8
8.7
8.3
HT7F3AS
HT7F6AS
HT7F9AS
HTP7F3AS
HTP7F6AS
HTP7F9AS
16.6
25.0
Group G: 208 Volt Δ Primary, 480Y/277 Secondary, 60 Hz
Catalog Number
Group I
Rolled Steel
Catalog Number
Group II
Approx. Ship
Weight
lbs (kg)
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Design
Style 1
Elec
Primary
Amps
Secondary
Amps
kVA
Conn 1
Stainless Steel 2
3
6
9
13.00 (330.2) 16.00 (406.4) 9.00 (228.6)
97.0 (44.00)
4
4
4
31
31
31
8.3
3.6
7.2
HT84F3AS
HT84F6AS
HT84F9AS
HTP84F3AS
HTP84F6AS
HTP84F9AS
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 256.0 (116.12)
16.6
25.0
10.8
Group H: 240 Volt Δ Primary, 480Y/277 Secondary, 60 Hz
Catalog Number
Group I
Rolled Steel
Catalog Number
Group II
Approx. Ship
Weight
lbs (kg)
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Design
Style 1
Elec
Primary
Amps
Secondary
Amps
kVA
Conn 1
Stainless Steel 2
3
6
9
13.00 (330.2) 16.00 (406.4) 9.00 (228.6)
97.0 (44.00)
4
4
4
32
32
32
7.2
3.6
7.2
HT85F3AS
HT85F6AS
HT85F9AS
HTP85F3AS
HTP85F6AS
HTP85F9AS
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 256.0 (116.12)
14.4
21.6
10.8
Group J: 480 Volt Δ Primary, 480Y/277 Secondary, 60 Hz
Catalog Number
Group I
Rolled Steel
Catalog Number
Group II
Approx. Ship
Weight
lbs (kg)
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Design
Elec
Primary Secondary
kVA
Style 1
Conn 1
Amps
Amps
Stainless Steel 2
3
6
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 121.0 (54.88)
13.00 (330.2) 16.00 (406.4) 9.00 (228.6) 150.0 (68.03)
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 255.0 (115.7)
17.00 (431.8) 20.00 (508.0) 11.00 (279.4) 261.0 (118.39)
30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 696.0 (315.70)
30.00 (762.0) 29.00 (736.6) 12.00 (304.8) 844.0 (382.83)
4
4
4
4
4
4
33
33
33
33
33
33
3.6
7.2
3.6
7.2
HT81F3AS
HT81F6AS
HT81F9AS
HT81F15AS
HT81F30AS
HT81F45AS
HTP81F3AS
HTP81F6AS
HTP81F9AS
HTP81F15AS
HTP81F30AS
HTP81F45AS
9
10.8
18.1
36.1
54.2
10.8
18.1
36.1
54.2
15
30
45
Notes:
1. Design Styles and Electrical Connections can be found at the end of the Non-Ventilated Distribution Transformers section.
2. Contact Technical Services for other enclosure types.
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© July 2020
221
Dry Type Distribution Transformers
Design Styles
D
W
H
Style 2 - Non-Encapsulated
W
D
H
Style 3 - Encapsulated
Style 4 - Encapsulated
Customized Enclosures - Contact Technical Services
Style 5 - Encapsulated
Available for all encapsulated kVA sizes (For Type 4, 12 and 4X)
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
222
© July 2020
Dry Type Distribution Transformers
Electrical Connections (Single Phase)
240 X 480 Volt Primary
120/240 Volt Secondary
Taps: None
240 X 480 Volt Primary
120/240 Volt Secondary
Taps: None
240 X 480 Volt Primary
120/240 Volt Secondary
Taps: 2, 2½% FCAN & FCBN
15
16
17
H8
H1
H2H3 H4
H5 H6
H7
H1
H3
H2
H4
H1
H3
H2
H4
SHIELD
X4
X1
X3
X2
SHIELD
Primary Voltage
Interconnect
H4 to H5
H3 to H5
H3 to H6
H2 to H6
H2 to H7
Connect Lines to
H1 & H8
X1
X3
X2
X4
X1
X3
X2
X4
504
492
480
468
456
Primary Voltage
Interconnect
Connect Lines to
Primary Voltage
Interconnect
Connect Lines to
H1 & H8
480
H2 to H3
H1 & H4
H1 & H8
480
H2 to H3
H1 & H4
H1 to H3
H2 to H4
H1 & H8
H1 to H3
H2 to H4
240
H1 & H4
240
H1 & H4
H1 & H8
Secondary Voltage
Interconnect
Connect Lines to
Secondary Voltage
Interconnect
Connect Lines to
H1 to H5
H4 to H8
252
240
228
H1 & H8
H1 & H8
H1 & H8
240
X2 to X3
X1 & X4
240
X2 to X3
X1 & X4
H1 to H6
H3 to H8
X2 to X3
X2 to
X2 to X3
X2 to
120-0-120
120
X1-X2-X4
X1 & X4
120-0-120
120
X1-X2-X4
X1 & X4
H1 to H7
H2 to H8
X1 to X3
X2 to X4
X1 to X3
X2 to X4
Secondary Voltage
Interconnect
Connect Lines to
HS1 Series
HS1 Series
240
X2 to X3
X1 & X4
240 X 480 Volt Primary,
120/240 Volt Secondary
Taps: 2, 2½% FCAN; 4, 2½% FCBN
X2 to X3
X2 to
120-0-120
120
X1-X2-X4
X1 & X4
18
H6 H7 H8 H9 H10
120/208/240/277 Volt Primary
120/240 Volt Secondary
Taps: None
19
X1 to X3
X2 to X4
H1
H2 H3 H4 H5
H1
H3
H2
H4 H5 H6
HS5 Series
120/208/240/277 Volt Primary
120/240 Volt Secondary
Taps: None
SHIELD
20
H8
X1
X3
X2
X4
SHIELD
H1 H2 H3
H4
H6
H7
H5
Primary Voltage
Interconnect
Connect Lines to
H1 & H10
H1 & H10
H1 & H10
H1 & H10
H1 & H10
H1 & H10
H1 & H10
X1
X3
X2
X4
504
492
480
468
456
444
432
H5 to H6
H4 to H6
H4 to H7
H3 to H7
H3 to H8
H2 to H8
H2 to H9
Primary Voltage
Interconnect
H2 to H3
H2 to H3
H2 to H3
Connect Lines to
H1 & H6
SHIELD
X4
277
240
208
X1
X3
X2
H1 & H5
Primary Voltage
Interconnect
H4 to H5
H3 to H6
H2 to H7
Connect Lines to
H1 & H8
H1 & H4
277
240
208
H1 to H3
H2 to H5
120
H1 & H5
H1 & H8
Secondary Voltage
Interconnect
Connect Lines to
H1 & H8
H1 to H6
H5 to H10
252
240
228
216
H1 & H10
H1 & H10
H1 & H10
H1 & H10
240
X2 to X3
X1 & X4
H1 to H6
H3 to H8
120
H1 & H8
H1 to H7
H4 to H10
X2 to X3
X2 to
120-0-120
120
X1-X2-X4
X1 & X4
Secondary Voltage
Interconnect
Connect Lines to
H1 to H8
H3 to H10
X1 to X3
X2 to X4
240
X2 to X3
X1 & X4
X2 to X3
X2 to
H1 to H9
H2 to H10
120-0-120
120
X1-X2-X4
X1 & X4
HS12 Series (1 kVA only)
X1 to X3
X2 to X4
Secondary Voltage
Interconnect
Connect Lines to
240
X2 to X3
X1 & X4
= Earth Ground
HS12 Series
X2 to X3
X2 to
120-0-120
120
X1-X2-X4
X1 & X4
X1 to X3
X2 to X4
Note:
Connect the electrostatic shield to the equipment ground (green) or to both the equipment ground and
the system ground (white). Specifications are subject to change without notice.
HS5 Series
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© July 2020
223
Dry Type Distribution Transformers
Electrical Connections (Single Phase)
600 Volt Primary
120/240 Volt Secondary
Taps: 2, 5% FCBN
22 190/200/208/220/380/400/415/4402Vol3t Pri.
H6
600 Volt Primary,
120/240 Volt Secondary
Taps: None
110/220 Volt Secondary
21
Taps: None
H1 H2 H3 H4 H5
H6 H7 H8 H9 H10
H1
H2 H3
H4 H5
H1
H2
SHIELD
SHIELD
X4
X1
Primary Voltage
X3
X2
X4
X1
X3
X2
Interconnect
H3 to H4
H2 to H4
H2 to H5
Connect Lines to
H1 & H6
X1
X3
X2
X4
Primary Voltage
Interconnect
Connect Lines to
600
570
540
Primary Voltage
Interconnect
Connect Lines to
440/460/480
415
H5 to H6
H4 to H6
H3 to H6
H2 to H6
H1 & H10
H1 & H9
H1 & H8
H1 & H7
H1 & H6
600
H1 & H2
H1 & H6
400/415
380/400
Secondary Voltage
Interconnect
X2 to X3
Connect Lines to
Secondary Voltage
Interconnect
Connect Lines to
240
X1 & X4
240
X2 to X3
X1 & X4
H1 to H6
H5 to H10
X2 to X3
220/230/240
208
H1 & H10
H1 & H9
H1 & H8
H1 & H7
120-0-120
120
X1, X2 & X4
X1 & X4
X2 to X3
X2 to
X2 to
m
120-0-120
120
X1-X2-X4
X1 & X4
H1 to H6
H4 to H9
X1 to X3
X2 to X4
X1 to X3
X2 to X4
H1 to H6
H3 to H8
HS10 Series
200/208
HS10 Series
Note:1 through 2 kVA units have electrostatic
shielding.
H1 to H6
H2 to H7
190/200/208
Secondary Voltage
Interconnect
Connect Lines to
190/200/208/220/380/400/415/440 Volt Pri.
110/220 Volt Secondary
220/230/240
X2 to X3
X1 & X4
Taps: None
24
110,220/115,
230/120,240
X2 to X3
X2 to
X1, X2 & X4
X1 & X4
H1
H2 H3 H4 H5
H6 H7 H8 H9 H10
X1 to X3
X2 to X4
110/115/120
HS14F1BS
SHIELD
X1
X3
Interconnect
X2
X4
Primary Voltage
Connect Lines to
440/460/480
415
H5 to H6
H4 to H7
H1 & H10
H1 & H10
400/415
380/400
H3 to H8
H2 to H9
H1 & H10
H1 & H10
H1 to H6,
H5 to H10
220/230/240
208
H1 & H10
H1 & H10
H1 & H10
H1 & H10
H1 to H7,
H4 to H10
H1 to H8,
H3 to H10
200/208
H1 to H9
H2 to H10
190/200/208
Secondary Voltage
Interconnect
Connect Lines to
= Earth Ground
220/230/240
X2 to X3
X1 & X4
X2 to X3
X2 to
110,220/115,
230/120,240
X1, X2 & X4
X1 & X4
X1 to X3
X2 to X4
Note:
110/115/120
Connect the electrostatic shield to the equipment ground (green) or to both the equipment ground and
the system ground (white). Specifications are subject to change without notice.
HS14 Series
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
224
© July 2020
Dry Type Distribution Transformers
Electrical Connections (Three Phase)
240 Δ Volt Primary
208Y/120 Volt Secondary
Taps: 2, 5% FCBN
H1
208 Δ Volt Primary
208Y/120 Volt Secondary
Taps: 2, 5% FCBN
480 Δ Volt Primary
208Y/120 Volt Secondary
Taps: 2, 5% FCBN
25
H3
27
H3
26
H2
H1
H2
H3
H1
H2
7 4 1
8 5 2
9 6 3
7 4 1
8 5 2
9 6 3
7 4 1
8 5 2
9 6 3
SHIELD
X3
SHIELD
SHIELD
X0
X1
X2
X0
X1
X2
X3
X0
X1
H2
X2
X3
X2
H2
X2
X3
X2
X3
H2
X1
X0
X1
X0
X1
X0
H1
H3
Connect Taps
X3
H1
H3
H1
H3
Primary
Voltage
Connect
Lines To
Primary
Voltage
Connect
Lines To
Primary
Voltage
Connect
Lines to
Connect Taps
Interconnect
240
1-H1 & 2-H2 & 3-H3
4-H1 & 5-H2 & 6-H3
7-H1 & 8-H2 & 9-H3
H1, H2, H3
H1, H2, H3
H1, H2, H3
208
1-H1 & 2-H2 & 3-H3
4-H1 & 5-H2 & 6-H3
7-H1 & 8-H2 & 9-H3
H1, H2, H3
H1, H2, H3
H1, H2, H3
480
1-H1 & 2-H2 & 3-H3
4-H1 & 5-H2 & 6-H3
7-H1 & 8-H2 & 9-H3
H1, H2, H3
H1, H2, H3
H1, H2, H3
228
456
198
216
187
432
Secondary
Voltage
Connect
Lines To
Secondary
Voltage
Connect
Lines To
Secondary
Voltage
Connect
Lines to
208
120
X1, X2, & X3
208
120
X1, X2, & X3
208
120
X1, X2, & X3
X0, X1, X2, X3
X0, X1, X2, X3
X0, X1, X2, X3
HT6 Series
HT3 Series
HT1 Series
480 Δ Volt Primary
480 Δ Volt Primary
240 Δ w/120 CT Volt Secondary
Taps: 2, 5% FCBN
380Y/220 Volt Secondary
Taps: 2, 5% FCBN
29
28
H3
H1
H2
H3
H1
H2
7 4 1
8 5 2
9 6 3
7 4
1
8
5
2
9 6 3
SHIELD
X3
SHIELD
X0
X1
X2
X6
X1
X2
X3
X2
H2
H2
X2
X6
X1
X0
H1
H3
X1
X3
H1
H3
X3
Primary
Voltage
Connect
Lines to
Primary
Voltage
Connect
Taps
Connect
Lines To
Interconnect
480
1-H1 & 2-H2 & 3-H3
4-H1 & 5-H2 & 6-H3
7-H1 & 8-H2 & 9-H3
H1, H2 & H3
H1, H2 & H3
H1, H2 & H3
480
456
432
1-H1 & 2-H2 & 3-H3
4-H1 & 5-H2 & 6-H3
7-H1 & 8-H2 & 9-H3
H1, H2, H3
H1, H2, H3
H1, H2, H3
456
432
= Earth Ground
Secondary
Voltage
Connect
Lines to
Secondary
Voltage
Connect
Lines To
Interconnect
Interconnect
380
220
X1, X2, X3
240
X1, X2, X3
X1-X6-X3
Notes:
X0, X1, X2, X3
120-0-120
X6 to
Connect the electrostatic shield to the equipment
ground (green) or to both the equipment ground
and the system ground (white). Specifications are
subject to change without notice.
HT79 Series
HT5 Series
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
© July 2020
225
Dry Type Distribution Transformers
Electrical Connections (Three Phase)
600 Δ Volt Primary
208Y/120 Volt Secondary
Taps: 2, 5% FCBN
208 Δ Volt Primary
480Y/277 Volt Secondary
Taps: 2, 5% FCBN
240 Δ Volt Primary
480Y/277 Volt Secondary
Taps: 2, 5% FCBN
32
30
H3
31
X3
H1
H2
X2
X1
X2
X3
X1
7 4 1
8 5 2
9 6
3
7 4 1
8 5 2
9 6 3
7 4 1
8 5 2
9 6 3
SHIELD
X3
SHIELD
H3
SHIELD
H3
X0
X1
X2
H0
H1
H2
H0
H1
H2
X2
H2
H2
H3
H2
X2
X2
X1
X0
H1
H0
H1
H0
H1
H3
X3
X1
X3
X1
X3
H3
Primary
Voltage
Primary
Voltage
Primary
Voltage
Connect Taps
Line Leads
Connect Taps
Line Leads
Connect Taps
Line Leads
600
1-H1 & 2-H2 & 3-H3
4-H1 & 5-H2 & 6-H3
7-H1 & 8-H2 & 9-H3
H1, H2, H3
H1, H2, H3
H1, H2, H3
208
1-X1 & 2-X2 & 3-X3
4-X1 & 5-X2 & 6-X3
7-X1 & 8-X2 & 9-X3
X1, X2, X3
X1, X2, X3
X1, X2, X3
240
1-X1 & 2-X2 & 3-X3
4-X1 & 5-X2 & 6-X3
7-X1 & 8-X2 & 9-X3
X1, X2, X3
X1, X2, X3
X1, X2, X3
570
198
228
540
187
216
Secondary
Voltage
Secondary
Voltage
Secondary
Voltage
Line Leads
Line Leads
Line Leads
208
120
X1, X2, X3
480
277
H1, H2, H3
480
277
H1, H2, H3
X0, X1, X2, X3
H0, H1, H2, H3
H0, H1, H2, H3
HT7 Series
HT84 Series
HT85 Series
480 Δ Volt Primary
480Y/277 Volt Secondary
Taps: 2, 5% FCBN
33
H1
H2
H3
7 4 1
8 5 2
9 6 3
SHIELD
X3
X0
X1
X2
X2
X3
H2
X1
X0
H1
H3
Primary
Voltage
Connect
Lines to
Interconnect
480
1-H1 & 2-H2 & 3-H3
4-H1 & 5-H2 & 6-H3
7-H1 & 8-H2 & 9-H3
H1, H2 & H3
H1, H2 & H3
H1, H2 & H3
456
432
Secondary
Voltage
Connect
Lines to
Interconnect
480
277
X1, X2, X3
X0, X1, X2, X3
HT81 Series
Notes:
Connect the electrostatic shield to the equipment ground (green) or to both the equipment ground and the system ground (white). Specifications are subject
to change without notice.
Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions.
226
© July 2020
HSP14F1.5CS-CE 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
HSP14F10BS | EMERSON-NETWORKPOWER | Automation Transformers - Non-Ventilated 50 VA to 45 kVA | 获取价格 | |
HSP14F1BS | EMERSON-NETWORKPOWER | Automation Transformers - Non-Ventilated 50 VA to 45 kVA | 获取价格 | |
HSP14F1CS-CE | EMERSON-NETWORKPOWER | Automation Transformers - Non-Ventilated 50 VA to 45 kVA | 获取价格 | |
HSP14F2BS | EMERSON-NETWORKPOWER | Automation Transformers - Non-Ventilated 50 VA to 45 kVA | 获取价格 | |
HSP14F2CS-CE | EMERSON-NETWORKPOWER | Automation Transformers - Non-Ventilated 50 VA to 45 kVA | 获取价格 | |
HSP14F3BS | EMERSON-NETWORKPOWER | Automation Transformers - Non-Ventilated 50 VA to 45 kVA | 获取价格 | |
HSP14F3CS-CE | EMERSON-NETWORKPOWER | Automation Transformers - Non-Ventilated 50 VA to 45 kVA | 获取价格 | |
HSP14F5BS | EMERSON-NETWORKPOWER | Automation Transformers - Non-Ventilated 50 VA to 45 kVA | 获取价格 | |
HSP14F5CS-CE | EMERSON-NETWORKPOWER | Automation Transformers - Non-Ventilated 50 VA to 45 kVA | 获取价格 | |
HSP14F7.5BS | EMERSON-NETWORKPOWER | Automation Transformers - Non-Ventilated 50 VA to 45 kVA | 获取价格 |
HSP14F1.5CS-CE 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6