TCF350RN [EATON]

UL Class CF branch circuit time-delay CUBEFuse;
TCF350RN
型号: TCF350RN
厂家: Eaton All Rights Reserved.    Eaton All Rights Reserved.
描述:

UL Class CF branch circuit time-delay CUBEFuse

文件: 总6页 (文件大小:1887K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
BUSSMANN  
Effective March 2019  
Supersedes January 2019  
Technical Data 9000  
SERIES  
UL Class CF branch circuit time-delay CUBEFuse  
Electrical characteristics  
•ꢀ  
10 seconds minimum operating time at 500%  
rated current  
2011/65/EU  
Agency information  
•ꢀ  
UL Listed Class CF fuse: Guide JDDZ, File  
E4273 (up to 400 A)  
CSA® Certified fuse: Class 1422-02,  
File 053787_C_000 (up to 100 A)  
•ꢀ  
•ꢀ  
CE (100 A and below)  
•ꢀ  
RoHS compliant  
Catalog symbols  
Watts loss at rated current  
•ꢀ  
TCF_ (indicating fuse, 6-400 A)  
Fuse amps  
Watts  
3.99  
6.23  
9.51  
18.6  
17. 6  
•ꢀ  
TCF_RN (non-indicating fuse, 1-400 A)  
30  
60  
Description  
The Bussmann™ series Low-Peak™ CUBEFuse™  
is a UL® Class CF current-limiting, dual-element,  
time-delay branch circuit fuse with Class J  
electrical performance. Available in indicating and  
non-indicating versions, this finger-safe fuse has  
a very compact, space-saving size and is easily  
applied using the CUBEFuse holder (TCFH_N), UL  
98 Compact Circuit Protector switch (CCP2-_CF)  
or Compact Circuit Protector Base (CCP2B up  
to 100 A) used in the Quik-Spec™ Coordination  
Panelboard).  
100  
200  
225  
400  
35.2  
Operating and storage temperature range  
•ꢀ  
-40 to 80°C (-40°F to 176°F)  
Catalog numbers (amps)  
Indicating CUBEFuse  
Ratings  
•ꢀ  
Volts  
TCF6  
TCF35  
TCF40  
TCF45  
TCF50  
TCF60  
TCF70  
TCF80  
TCF90  
TCF225  
TCF250  
TCF300  
TCF350  
TCF400  
•ꢀ 600 Vac  
•ꢀ 300 Vdc  
TCF10  
TCF15  
TCF17-1/2  
TCF20  
TCF25  
TCF30  
TCF100  
TCF110  
TCF125  
TCF150  
TCF175  
TCF200  
•ꢀ  
Amps  
•ꢀ 6-400 A (indicating)  
•ꢀ 1-400 A (non-indicating)  
•ꢀ  
Interrupting rating  
•ꢀ 300 kA RMS Sym. (Up to 100 A UL)  
•ꢀ 200 kA RMS Sym. (110 to 400 A UL)  
•ꢀ 200 kA RMS Sym. (Up to 100 A CSA)  
Non-Indicating CUBEFuse  
TCF1RN  
TCF3RN  
TCF6RN  
TCF10RN  
TCF15RN  
TCF25RN TCF70RN  
TCF30RN TCF80RN  
TCF35RN TCF90RN  
TCF175RN  
TCF200RN  
TCF225RN  
•ꢀ 100 kA DC (Up to 400 A UL and up to 100 A  
CSA)  
TCF40RN TCF100RN TCF250RN  
TCF45RN TCF110RN TCF300RN  
TCF17-1/2RN TCF50RN TCF125RN TCF350RN  
TCF20RN TCF60RN TCF150RN TCF400RN  
Technical Data 9000  
UL Class CF branch circuit time-delay CUBEFuse  
Effective March 2019  
Features  
Dimensions — in (mm)  
•ꢀ  
Smallest installed footprint of any UL Class CC, J, or R fuse  
solution  
B
C
•ꢀ  
Easy application using CUBEFuse holders (TCFH_N), UL 98  
Compact Circuit Protector (CCP2) switches and Compact Circuit  
Protector Base (CCP2B up to 100 A). See data sheet 9007 for  
details on the CUBEFuse holder, 10801 for details on the CCP2-_  
CF switch and 1161 for the CCP2B.  
A
Up to 100 A  
•ꢀ  
Holders and switches have an amp rating rejection feature to help  
prevent overfusing; 30, 60 and 100 A switches and holders will  
hold any CUBEFuse up to its rating, 200 and 400 A switches and  
200, 225 and 400 A holders will hold any CUBEFuse 110 A and  
above up to its rating  
D
E
B
C
•ꢀ  
UL Class CF with Class J time-delay electrical performance  
•ꢀ  
Available in indicating and non-indicating versions  
•ꢀ  
The indicating version features local easyID™ open fuse  
technology for faster troubleshooting and reduced downtime  
A
•ꢀ  
Faster response to damaging faults helps reduce destructive  
thermal and magnetic forces  
110 to 400 A  
D
•ꢀ  
True dual-element fuse construction with a minimum 10 seconds  
time-delay at 500% of rating  
E
•ꢀ  
Long time-delay minimizes nuisance openings caused by  
temporary overloads and transient surges  
Fuse  
•ꢀ  
amps  
1-15  
17-1/2  
20  
A
B
C
D
E
Up to 300 kA interrupting rating safely interrupts virtually any fault  
•ꢀ  
0.23 (6)  
Robust cycling and inrush current withstand  
•ꢀ  
Low let-through currents under fault conditions  
1.88 (48)  
0.75 (19)  
1.0 (25)  
0.27 (7)  
•ꢀ  
Provides Type 2 “No Damage” protection for IEC motor starters  
when properly sized  
25-30  
35-40  
45-50  
60  
0.31 (8)  
0.36 (9)  
0.67 (17)  
•ꢀ  
Easy selective coordination with any other Bussmann series  
Low-Peak Class CC, J, L or RK1 fuse with simple 2:1 amp ratio  
between upstream and downstream fuses  
2.13 (54)  
3.01 (76)  
1.13 (29)  
1.26 (32)  
0.44 (11)  
* Finger-safe status depends on final, installed application, and will require using  
accessory shrouds for 110 to 400 A ratings.  
1.0 (25)  
70  
0.49 (12)  
0.57 (14)  
80-90  
100  
0.64 (16)  
110  
0.51 (13)  
0.51 (13)  
0.51 (13)  
125  
150  
3.62 (92)  
2.9 (74)  
1.34 (34)  
1.69 (43)  
1.02 (26)  
1.47 (36)  
175  
0.57 (14.5)  
0.57 (14.5)  
0.63 (16)  
200  
225  
250  
0.73 (18.5)  
0.79 (20)  
300  
350  
4.25 (108)  
3.46 (88)  
0.86 (21.5)  
0.86 (21.5)  
400  
Carton quantity and weight  
Amp range  
Up to 30  
35-60  
Carton qty.  
Weight per carton lb (kg)  
1.39 (0.63)  
12  
12  
6
1.42 (0.64)  
70-100  
1.74 (0.79)  
110 to 225  
250 to 400  
1
0.71 (0.32)  
1
1.23 (0.56)  
2
Eaton.com/bussmannseries  
UL Class CF branch circuit time-delay CUBEFuse  
Technical Data 9000  
Effective March 2019  
Up to 100 A time-current characteristics — average melt  
110 to 400 A time-current characteristics — average melt  
1000  
100  
10  
1
0.1  
0.01  
CURRENT IN AMPS  
Up to 100 A current let-through curves  
110 to 400 A current let-through curves  
B
100,000  
400A  
250A  
225A  
200A  
110A  
10,000  
1,000  
A
100  
PROSPECTIVE SHORT CIRCUIT CURRENT  
SYMMETRICAL RMS AMPS  
Eaton.com/bussmannseries  
3
Technical Data 9000  
UL Class CF branch circuit time-delay CUBEFuse  
Effective March 2019  
Motor sizing table (from NECTables 430.248 and 430.250)  
Bussmann seriesTCF Low-Peak time-delay Class CF fuses  
NEC  
code max  
(amps)  
Heavy  
start*  
(amps)  
NEC  
code max  
(amps)  
Heavy  
start*  
(amps)  
Motor size Motor FLA  
Min  
(amps)  
Motor size Motor FLA  
Min  
(amps)  
Voltage  
(Hp)  
0.167  
0.25  
0.333  
0.5  
0.75  
1
(amps)  
4.4  
5.8  
7. 2  
Voltage  
(Hp)  
0.5  
0.75  
1
(amps)  
2.4  
3.5  
4.6  
6.6  
7. 5  
10  
10  
10  
15  
10  
15  
6
6
6
10  
6
10  
15  
15  
25  
25  
30  
40  
50  
90  
125  
150  
6
15  
15  
10  
10  
10  
9.8  
13.8  
16  
20  
25  
30  
35  
45  
60  
100  
150  
175  
6
20  
1.5  
2
10  
15  
15  
30  
15  
15  
15  
35  
3
10.6  
16.7  
24.2  
59.4  
74.8  
88  
17. 5  
25  
40  
90  
125  
150  
175  
225  
300  
6
20  
20  
115 Vac,  
1-phase  
1.5  
2
20  
45  
5
30  
35  
208 Vac,  
3-phase  
24  
50  
7. 5  
20**  
25  
30  
40  
50  
60  
0.5  
0.75  
1
45  
50  
3
34  
70  
110  
150  
175  
200  
300  
300  
6
125  
150  
175  
250  
300  
350  
6
5**  
7. 5  
56  
125  
175  
225  
6
80  
10  
100  
2.2  
2.9  
3.6  
4.9  
6.9  
8
114  
143  
169  
2.2  
3.2  
4.2  
6
0.167  
0.25  
0.333  
0.5  
0.75  
1
6
6
6
6
10  
10  
10  
10  
10  
6
6
6
15  
15  
15  
20  
25  
45  
60  
80  
6
15  
15  
10  
10  
10  
15  
17. 5  
20  
1.5  
2
10  
15  
15  
230 Vac,  
1-phase  
1.5  
2
10  
20  
25  
30  
50  
70  
90  
6
6.8  
9.6  
15.2  
22  
15  
15  
15  
12  
25  
3
15  
20  
20  
3
17  
35  
5
25  
35  
90  
110  
125  
175  
200  
250  
300  
3
30  
30  
230 Vac,  
3-phase  
5
28  
60  
7. 5  
20**  
25  
30  
40  
50  
60  
75  
0.5  
0.75  
1
40  
45  
7. 5  
40  
90  
54  
100  
125  
150  
200  
250  
300  
350  
3
110  
150  
175  
225  
250  
300  
400  
3
10**  
0.5  
0.75  
1
50  
110  
6
68  
2.5  
3.7  
4.8  
6.9  
7. 8  
80  
6
10  
10  
104  
130  
154  
192  
1.1  
10  
10  
10  
1.5  
2
15  
15  
17. 5  
30  
40  
100  
125  
150  
200  
225  
300  
15  
15  
15  
17. 5  
20  
3
11  
20  
35  
45  
110  
150  
175  
225  
300  
350  
5
17. 5  
25.3  
62.1  
78.2  
92  
35  
1.6  
3
3
3
200 Vac,  
3-phase  
7. 5  
50  
2.1  
3
6
6
6
20**  
25  
125  
175  
200  
250  
300  
350  
1.5  
2
6
6
6
3.4  
4.8  
7. 6  
6
6
6
30  
3
10  
10  
10  
40  
120  
150  
177  
5
15  
15  
15  
50  
7. 5  
10  
11  
17. 5  
25  
35  
40  
100  
125  
150  
200  
250  
300  
20  
20  
460 Vac,  
3-phase  
60  
14  
25  
30  
Note: Use NEC code max column for low to moderate reverse/jog/  
15  
21  
40  
45  
plug applications.  
20  
50**  
60  
75  
100  
125  
150  
27  
50  
60  
* Heavy Start permitted only if NEC code max does not allow motor start-up.  
**If equipment terminations are rated for 60°C conductors only, the 60°C  
conductor ampacities must be utilized and therefore larger conductor sizes or  
conduit sizes may be required.  
65  
125  
150  
175  
225  
300  
350  
125  
150  
200  
250  
350  
400  
77  
96  
124  
156  
180  
Note: Use NEC code max column for low to moderate reverse/jog/  
plug applications.  
* Heavy Start permitted only if NEC code max does not allow motor start-up.  
**If equipment terminations are rated for 60°C conductors only, the 60°C  
conductor ampacities must be utilized and therefore larger conductor sizes or  
conduit sizes may be required.  
4
Eaton.com/bussmannseries  
UL Class CF branch circuit time-delay CUBEFuse  
Technical Data 9000  
Effective March 2019  
Motor sizing table (from NECTables 430.248 and 430.250)  
Bussmann seriesTCF Low-Peak time-delay Class CF fuses  
NEC  
code max  
(amps)  
Heavy  
start*  
(amps)  
Motor size Motor FLA  
Min  
Voltage  
(Hp)  
0.5  
0.75  
1
(amps)  
0.9  
1.3  
1.7  
2.4  
2.7  
3.9  
6.1  
9
(amps)  
3
3
3
3
3
3
3
3
3
1.5  
2
6
6
6
6
6
6
3
6
10  
10  
5
10  
15  
20  
20  
15  
7. 5  
10  
15  
17. 5  
70  
20  
20  
575 Vac,  
3-phase  
11  
41  
40**  
80  
80  
50  
52  
80  
100  
125  
150  
200  
225  
300  
100  
110  
150  
175  
225  
300  
350  
110  
125  
150  
200  
250  
300  
400  
60  
62  
75  
77  
100  
125  
150  
200  
99  
125  
144  
192  
Note: Use NEC code max column for low to moderate reverse/jog/  
plug applications.  
* Heavy Start permitted only if NEC code max does not allow motor start-up.  
**If equipment terminations are rated for 60°C conductors only, the 60°C  
conductor ampacities must be utilized and therefore larger conductor sizes or  
conduit sizes may be required.  
Eaton.com/bussmannseries  
5
Technical Data 9000  
UL Class CF branch circuit time-delay CUBEFuse  
Effective March 2019  
200 and 400 A Compact Circuit Protector (cat. no. CCP2-CF)  
CUBEFuse (cat. no.TCFH_N) holders  
switches  
The CUBEFuse is used in holders that can be dovetail together for  
the smallest footprint possible of any Class J fuse solution (see data  
sheet no. 9007 for details).  
These panel mounted 1-, 2-  
and 3-pole switches are UL 98  
horsepower rated disconnects.  
Each CCP2 will accept a fuse  
amp rating equal to or less than  
its rating (e.g., a 200 A CCP will  
accept any CUBEFuse from 110  
to 200 A). Complete installation  
requires installing various  
Finger-safe DIN-Rail or panel  
mount holders up to 100 A.  
•ꢀ  
30 A holder accepts any  
CUBEFuse up to 30 A.  
lugs to meet the application  
requirement. Accessories  
include side or front rotary  
operators and auxiliary contacts  
(see data sheet no. 10801 for  
details).  
•ꢀ  
60 amp holder accepts any  
CUBEFuse up to 60 A.  
•ꢀ  
100 amp holder accepts any  
CUBEFuse up to 100 A.  
Panel mount holders from  
200 to 400 A.  
Compact Circuit Protector Base (cat. no. CCP2B)  
•ꢀ  
200 A holder accepts any  
CUBEFuse from 110 to 200 A  
These 1-, 2- and 3-pole switches  
are UL 98 horsepower rated  
branch circuit disconnects.  
Primarily used in the Quik-Spec  
Coordination Panelboard, they’re  
available in ratings up to 100 A.  
The CCP2B has amp rejection  
breaks that prevent installing  
any CUBEFuse amp rating  
greater than that of the switch.  
These coincide with standard  
conductor ampacities to help  
prevent overfusing and are  
•ꢀ  
225 A* holder accepts any  
CUBEFuse from 110 to 225 A  
•ꢀ  
400 A holder accepts any  
CUBEFuse from 110 to 400 A  
Finger-safe installation  
achievable for three ganged  
holders and lug kits with shroud  
* 200 A and 225 A holders share the  
same overall dimensions, but the  
200 A holder will reject a 225 A fuse.  
available at 15, 20, 30, 40, 50,  
60, 70, 90 and 100 amps for all  
1-, 2- and 3-pole switches.  
30, 60 and 100 A Compact Circuit Protector (cat. no.CCP2_CF)  
switches  
These DIN-Rail mounted 1-, 2-  
and 3-pole switches are UL 98  
horsepower rated disconnects  
available with front or side  
rotary operators. Each CCP2  
will accept a fuse amp rating  
equal to or less than its rating  
(e.g., a 60 A CCP will accept  
any CUBEFuse up to 60 A).  
Accessories include multi-wire  
lug kits with shrouds, auxiliary  
contacts and PLC fuse monitor  
(see data sheet no. 10801 for  
details).  
The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document  
are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help  
the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue  
or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this  
bulletin. Once a product has been selected, it should be tested by the user in all possible applications.  
Eaton  
1000 Eaton Boulevard  
Cleveland, OH 44122  
United States  
For Eatons Bussmann series  
product information,  
call 1-855-287-7626 or visit:  
Eaton.com/bussmannseries  
Eaton.com  
Eaton, Bussmann, CUBEFuse, Low-Peak,  
easyID and Quik-Spec are valuable trademarks  
of Eaton in the US and other countries. You  
are not permitted to use the Eaton trademarks  
without prior written consent of Eaton.  
Bussmann Division  
114 Old State Road  
Ellisville, MO 63021  
United States  
Eaton.com/bussmannseries  
CSA is a registered trademark of the Canadian  
Standards Group  
Follow us on social media to get the  
latest product and support information.  
© 2019 Eaton  
All Rights Reserved  
Printed in USA  
NEC is a registered trademark of the National  
Fire Protection Association  
Publication No. 9000 – BU-SB18086  
March 2019  
UL is a registered trademark of the  
Underwriters Laboratories, Inc.  

相关型号:

TCF35RN

Low-Peak CUBEFuse With and Without Indication
COOPER

TCF35RN

UL Class CF branch circuit time-delay CUBEFuse
EATON

TCF3A1031034D1

Lead Frame for Temperature Sensing/Compensation
THINKING

TCF3A1031034D2

Lead Frame for Temperature Sensing/Compensation
THINKING

TCF3A1031034D3

Lead Frame for Temperature Sensing/Compensation
THINKING

TCF3A103134D1

Lead Frame for Temperature Sensing/Compensation
THINKING

TCF3A103134D2

Lead Frame for Temperature Sensing/Compensation
THINKING

TCF3A103134D3

Lead Frame for Temperature Sensing/Compensation
THINKING

TCF3A103234D1

Lead Frame for Temperature Sensing/Compensation
THINKING

TCF3A103234D2

Lead Frame for Temperature Sensing/Compensation
THINKING

TCF3A103234D3

Lead Frame for Temperature Sensing/Compensation
THINKING

TCF3A103334D1

Lead Frame for Temperature Sensing/Compensation
THINKING