SPP40SP3240DLG [EATON]
SurgePOD⢠PRO UL Listed Type 1 surge protective devices;型号: | SPP40SP3240DLG |
厂家: | Eaton All Rights Reserved. |
描述: | SurgePOD⢠PRO UL Listed Type 1 surge protective devices |
文件: | 总4页 (文件大小:1378K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Effective April 2018
Technical Data 10033
Supersedes February 2016
SurgePOD™ PRO UL Listed Type 1 surge
protective devices
Features:
•ꢀ
These SPDs are easily selected and installed on
the loadside or lineside of the service entrance
overcurrent protective device
2011/65/EU
•ꢀ
Voltage specific models precisely match and
protect electrical systems and equipment better
than “one-size-fits-all” SPDs
•ꢀ
•ꢀ
•ꢀ
•ꢀ
Thermal disconnect technology eliminates the
need for additional fusing
Compact UV resistant NEMA® 4X enclosure for
indoor or outdoor installation
easyID™ LED status indicator provides surge
protection status at a glance
Two year warranty
Specifications:
Ratings
•ꢀ
See ratings and specifications tables on page 2
Catalog symbols:
Agency information
UL® Listed Type 1 1449 4th Edition
•ꢀ
SPP40SP_
•ꢀ
•ꢀ
•ꢀ
CSA (120-480 V)
Description:
RoHS compliant
Bussmann™ series SurgePOD™ PRO Type
1 surge protective devices are suitable for
installation on both the loadside or lineside of the
service entrance overcurrent protective device.
Catalog numbers
SPP40SP1120SN
SPP40SP2240PN
Volts AC System type
120
240
Single-phase
Split-phase
SurgePOD PRO SPDs are available in popular
voltage and system specific versions to match
common residential and light commercial electrical
system and equipment requirements. They deliver
superior surge protection using MOV thermal
disconnect technology that eliminates the need for
additional overcurrent protection.
SPP40SP3240DLG 240
SPP40SP3480DLG 480
SPP40SP3208WYG 208
SPP40SP3480WYG 480
SPP40SP3600WYG 600
3-phase Delta
3-phase Wye
Parallel connection to the electrical system permits
the SurgePOD PRO SPD to be installed on panels
of any amp rating.
Technical Data
SurgePOD™ PRO UL ListedType 1 surge protective devices
Effective April 2018
SurgePOD PRO ratings and specifications:
Voltages and system types
Max. Continuous
Nominal system voltage
(Vac)
Operating Voltage AC
Catalog number
(MCOV) (VC)
System type
Connection points
SPP40SP1120SN
SPP40SP2240PN
SPP40SP3240DLG
SPP40SP3480DLG
SPP40SP3208WYG
SPP40SP3480WYG
120
120/240
240
480
208
150
150
320
550
150
320
Single-phase 2 wire
Split-phase 3 wire
Three-phase Delta 3 wire + G
Three-phase Delta 3 wire + G
Three-phase Wye 3 wire + G
Three-phase Wye 3 wire + G
2
3
4
4
4
4
480
Specifications
For all SurgePOD PRO units
Values
200 kA
10 kA
Short Circuit Current Rating (SCCR)
Nominal In
Maximum Imax
Discharge current (8x20µs)
40 kA
Response time (ns) tA
Frequency
<25ns
50/60 Hz
Operating state/fault indication
Conductor length/gauge
Bi-color LED - green (good) / red (replace)
18 inches, 10 AWG stranded tinned copper
Mounting
Chase nipple / bracket*
Enclosure/flammability ratings
Degree of protection (installed state)
SPD install location
NEMA 4X - UL 94-5VA
IP20 (finger-safe)
Indoor/outdoor
Circuit location
Lineside or loadside of service entrance overcurrent protective device
UL Type 1 1449 4th Edition
Standard
Agency information
UL Listed, CSA Certified**, RoHS compliant
2 Years†
Warranty
Operating temperature range
Maximum operating altitude
-40°C to +65°C
12000 ft.
*
Customer-supplied bracket.
** 600 V Wye version not CSA Certified.
†
See Bussmann series SPD limited warranty statement (3A1502) for details at www.cooperbussmann.com/Surge.
Voltage Protection Ratings (VPRs)
Voltage Protection Ratings (VPRs)
Nominal system voltage
(Vac_
Catalog number
SPP40SP1120SN
MCOV (VC) (Vac)
L-N
700
700
—
L-L
L-G
—
120
150
150
320
550
150
320
420
—
SPP40SP2240PN
SPP40SP3240DLG
SPP40SP3480DLG
SPP40SP3208WYG
SPP40SP3480WYG
SPP40SP3600WYG*
120V/240
240
1200
2500
3000
1200
2500
2500
—
1200
1800
700
1200
1500
480
—
208
—
480
—
600
—
*
Not CSA Certified.
Eaton.com/bussmannseries
2
SurgePOD™ PRO UL ListedType 1 surge protective devices
Technical Data 10033
Effective April 2018
Dimensions — in
Wiring connections
L (Black)
1-1/16” Dia.
1-11/16”
Black
N (White)
3-3/8”
White
1-11/16”
Single-phase
120 V (L-N) 2 Wire
2-1/16”
4-1/8”
2-1/16”
Must be installed within 10 feet (3 m) of a bonded neutral-ground
connection per IEEE C62.41-1991.
Catalog number: SPP40SP1120SN
3-3/16”
4-1/16”
L1 (Black)
7/8”
N (White)
Black
Black
Mounting
L2 (Black)
SurgePOD PRO is a panel mount device. It may also be mounted
using a customer supplied bracket or directly onto a female threaded
conduit fitting.
White
Two-pole with Neutral (split-phase)
120 V (L-N) / 240 V (L1-L2), single-phase (split) center tap
For installations at or less than 10 feet (3 m) from the transformer.
Catalog number: SPP40SP2240PN
For NEMA 4X installation,
install appropriate, customer-
supplied gasket between
SurgePOD™ PRO
SPD and enclosure wall.
L1 (Black)
L2 (Black)
Tighten locknut to
Black
20.3 lb-in (2.3N•m)
Black
Black
L3 (Black)
GND (Green)
Green
Wye + Ground
208, 480 V (L-L) 3 wire Wye + Ground
Catalog numbers: SPP40SP3208WYG, SPP40SP3480WYG,
SPP40SP3600WYG
L1 (Black)
L2 (Black)
Black
L3 (Black)
Black
Black
GND (Green)
Green
Delta + Ground
240, 480 V (L-L) 3 wire Delta + Ground
Catalog numbers: SPP40SP3240DLG, SPP40SP3480DLG
Eaton.com/bussmannseries
3
Technical Data 10033
SurgePOD™ PRO UL ListedType 1 surge protective devices
Effective April 2018
easyID LED status indicator
The easyID LED status indicator will illuminate when the unit is
properly installed and the system or equipment being protected is
energized. The following LED color/status indicates:
GREEN LED = Good
•ꢀ
The circuit is energized and protected.
RED LED = Replace
•ꢀ
The circuit is energized and unprotected.
•ꢀ
The unit needs replacing.
LED is Out / Unlit:
•ꢀ
The circuit is most likely de-energized
•ꢀ
The unit’s leads are disconnected
•ꢀ
The unit is damaged
Authorized personnel should follow all
prescribed lockout/tagout and safety
procedures in troubleshooting the cause for
the above conditions. Opening SurgePOD
PRO enclosure will void UL listing and
warranty.
The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are
by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the
end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit
distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once
a product has been selected, it should be tested by the user in all possible applications.
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
Eaton.com
Bussmann Division
Eaton, Bussmann, SurgePOD and easyID are
114 Old State Road
valuable trademarks of Eaton in the U.S. and
Ellisville, MO 63021
other countries. You are not permitted to use
United States
the Eaton trademarks without prior written
Eaton.com/bussmannseries
consent of Eaton.
Follow us on social media to get the
latest product and support information.
© 2018 Eaton
All Rights Reserved
Printed in USA
NEMA is a registered trademark of the
National Electrical Manufacturers Association.
Publication No. 10033 — BU-SB13071
April 2018
UL is a registered trademark of the
Underwriters Laboratories, Inc.
相关型号:
SPP40SP3480DLG
SURGE PROTECTION MADE SIMPLE⢠FOR LIGHT COMMERCIAL & RESIDENTIAL APPLICATIONS
COOPER
SPP40SP3480WYG
SURGE PROTECTION MADE SIMPLE⢠FOR LIGHT COMMERCIAL & RESIDENTIAL APPLICATIONS
COOPER
SPP42N03S2L13AKSA1
Power Field-Effect Transistor, 42A I(D), 30V, 0.0199ohm, 1-Element, N-Channel, Silicon, Metal-oxide Semiconductor FET, TO-220AB, PLASTIC, TO-220, 3 PIN
INFINEON
©2020 ICPDF网 联系我们和版权申明