PACSR24012 [DELTA]

24V Output AC/DC Converter, Module Package;
PACSR24012
型号: PACSR24012
厂家: DELTA ELECTRONICS, INC.    DELTA ELECTRONICS, INC.
描述:

24V Output AC/DC Converter, Module Package

文件: 总7页 (文件大小:785K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
PACSR24012  
24V Output AC/DC Converter, Module Package  
FEATURES  
Full Load Efficiency up to 92.5% @220VAC  
Metal Case Box Type Package  
Package Dimension:  
110.8x50.8x13.7mm (4.36”x2.0”x0.54”)  
Operating Baseplate Temperature Range - 40°C to  
+100°C  
Input Brown-Out, Output OCP, OTP, OVP, SHORT  
protection  
3000VAC Isolation  
RoHs Compliant  
CE Mark  
EMC compatible: CISPR22 ClassBwith EMC Board)  
ISO 9001, ISO 14001 certified manufacturing facility  
UL60950-1 (US&Canada)  
The PACSR24012, a wide input voltage range of 90~264VAC, and single isolated output converter, is the latest product offering from a  
world leader in power systems technology and manufacturing ― Delta Electronics, Inc. Such module type ACDC converter can provide 300W,  
24V regulated DC output voltage with full load efficiency up to 92.5% @220Vac; The PACSR24012 offers Brown-out, output OCP, OTP, OVP  
and Short protections, and allows a wide operating baseplate temperature range of 40°C to +100°C. With creative design technology and  
optimization of component placement, this converter possess outstanding electrical and thermal performance, as well as high reliability under  
extremely harsh operating conditions.  
Input Characteristics  
Item  
Condition  
Min.  
100  
90  
Typ.  
Max.  
240  
264  
65  
Unit  
VAC  
VAC  
Hz  
Rated input voltage range  
Max input voltage range  
Input voltage frequency range  
110/220  
45  
50/60  
2.5  
Maximum Input Current  
Open load loss  
Vin=85VAC, 100% Load  
Vin=110VAC, 100% Load  
4.5  
A
W
Input PF value  
95  
%
Output Characteristics  
Item  
Conditions  
Min.  
Typ.  
24  
Max.  
24.4  
12.5  
16  
Unit  
Output voltage setpoint  
Out put current range  
Output OCP point  
Turn-on rise time  
Start up time  
Vin=220VAC, Io=0-12.5A  
23.6  
0
Vdc  
A
13  
14.5  
20  
A
ms  
mS  
mS  
V
Vin=110/220VAC  
1500  
20  
Hold up time  
Vin=110/220VAC, Io= 100% Load  
Output OVP point  
27.5  
29  
30.5  
10  
5
Trim up  
%
Output trim range  
Trim down  
Positive voltage step, 75% to 25% load  
dynamic, 0.1A/us slew rate  
Negative voltage step, 25% to 75% load  
dynamic, 0.1A/us slew rate  
Vin=110/220Vac, 100% Load, peak to peak,  
20MHz bandwidth  
%
800  
800  
1000  
1000  
mV  
mV  
mV  
Output Current Transient  
150  
80  
Output Voltage Ripple and Noise  
RMS  
mV  
%
Output overshoot  
3
89.5  
Efficiency @ 60% Load  
Vin=110VAC  
%
DS_PACSR24012_05232017  
E-mail: dcdc@deltaww.com  
http://www.deltaww.com/dcdc  
P1  
90.5  
91.5  
92.5  
Efficiency @ 60% Load  
Efficiency @ 100% Load  
Efficiency @ 100% Load  
General Characteristics  
Item  
Vin=220VAC  
Vin=110VAC  
Vin=220VAC  
%
%
%
Conditions  
Input to output  
Input to case  
Output to case  
500Vdc  
Min.  
10  
Typ.  
3000  
1500  
500  
Max.  
Unit  
VAC  
VAC  
VAC  
MΩ  
I/O Isolation Voltage  
I/O Isolation Resistance  
MTBF  
Ta=25ºC, 100%load  
1
Mhours  
g
Weight  
240  
Environmental Specifications  
Parameter  
Storage Temperature Range  
Operating Temperature Range  
Operating altitude  
Conditions  
Min.  
-40  
Max.  
+125  
+105  
3000  
Unit  
Case Temperature  
-40  
meter  
ELECTRICAL CURVE  
Figure 1: Efficiency vs. Output current @ Vin=110,220VAC  
Figure 2: Vout vs. Vin @ Full load  
.
Figure 3: Output voltage vs. Output current @  
Vin=110/220VAC  
DS_PACSR24012_05232017  
E-mail: dcdc@deltaww.com  
http://www.deltaww.com/dcdc  
P2  
ELECTRICAL CURVES (continous)  
Figure 4: Dynamic response to load step 3A~9A with 0.1A/uS  
slew rate at 110/220Vac  
Figure 5: Vout start up with Enable on at 220Vac,12A Iout,  
TOP:Vout, 10V/div, 500mS/div  
TOP: Vout, 200mV/div, BOTTOM:Iout,10A/div,1mS/div  
BOTTOM: Vin, 500V/div, 500mS/div  
Figure 6: Output ripple & noise at 110/220Vac, 12A Iout  
CH4:VOUT, 50mV/div, 5mS/div  
Figure 7: Output over voltage protection at 110/220Vac,12A  
Iout. CH4:VOUT, 5V/div, 500mS/div  
Figure 8: Inrush current @ Vin=220Vac. CH2:Iin, 10A/div,  
5mS/div;  
DS_PACSR24012_05232017  
E-mail: dcdc@deltaww.com  
http://www.deltaww.com/dcdc  
P3  
SIMPLIFIED APPLICATION CIRCUIT  
Figure 9: Application connection  
TYPICAL value ADVISED  
No  
Locati  
on  
item  
value  
Part No  
Cap1  
bus cap  
220uF/450V  
Capacitor  
should  
have  
good  
1
low-temperature characteristics, keep at  
least 75% capacitance at -40if need  
-40C application.  
Cap2  
bus cap  
220uF/450V  
2
Cap3  
Cap4  
Cap for pri-sec  
Output cap  
2200pF/250Vac Y1/X1  
1000uF/35V  
3
4
ESR 16m Ω (100kHz), Rated ripple ≥  
2920mArms(105)  
Cap5  
Cap6  
Cap7  
Cap8  
F1  
RV1  
RV2  
RV3  
RV4  
GT1  
C1  
Output cap  
Output cap  
Output cap  
Output cap  
Input Fuse  
Input VDR  
Input VDR  
Input VDR  
Input VDR  
Input GAS TUBE  
Input Y-cap  
Input Y-cap  
Input X-cap  
Input X-cap  
Input X-cap  
Input Y-cap  
Input Y-cap  
Cap for pri-PE  
output Y-cap  
output Y-cap  
output Y-cap  
output Y-cap  
Input Y-cap  
Input Y-cap  
Input chock  
Input chock  
270uF/35V  
270uF/35V  
270uF/35V  
270uF/35V  
6.3A/250Vac  
300VAC  
300VAC  
150VAC  
5
6
7
8
ESR 17m Ω (100kHz), Rated ripple ≥  
2200mArms(125)  
9
TVR14471KOOOTB9Y/THINKING  
TVR14471KOOOTB9Y/THINKING  
JVH10N241K87YAW/JOYIN  
JVH10N241K87YAW/JOYIN  
B88069X8661S102(EF2500X8S)  
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
150VAC  
2.5KV/10KA  
100pF/250Vac Y2/X1  
4700pF/250Vac Y2/X1  
1uF /305VAC X2  
0.47uF /275VAC X2  
0.47uF /275VAC X2  
100pF/250Vac Y2/X1  
4700pF/250Vac Y2/X1  
1500pF/250Vac Y1/X1  
4700pF/250Vac Y2/X1  
4700pF/250Vac Y2/X1  
4700pF/250Vac Y2/X1  
4700pF/250Vac Y2/X1  
100pF/250Vac Y2/X1  
100pF/250Vac Y2/X1  
7mH 33T φ0.8mm  
7mH 33T φ0.8mm  
C2  
C3  
C4  
C5  
C6  
C7  
C8  
C9  
C10  
C11  
C12  
C13  
C14  
L1  
Mn-Zn core, Ui10000, L7mH  
L2  
DS_PACSR24012_05232017  
E-mail: dcdc@deltaww.com  
http://www.deltaww.com/dcdc  
P4  
THERMAL CONSIDERATION  
Thermal management is an important part of the system design. To ensure proper, reliable operation,  
sufficient cooling of the power module is needed over the entire temperature range of the module. Conduction  
cooling is usually the dominant mode of heat transfer.  
Thermal Testing Setup  
The following figure shows the testing setup in which the power module is mounted on an Al plate and  
was cooled by cooling liquid.  
Figure 10: Thermal test setup  
THERMALDERATING CURVE  
The following figure shows the location to monitor the temperature of the modules baseplate. The  
baseplate temperature in thermal curve is a reference for customer to make thermal evaluation and make sure  
the module is operated under allowable temperature. (Thermal curves shown in Figure12 are based on different  
input voltage).  
Figure 11: Baseplates temperature measured point  
DS_PACSR24012_05232017  
E-mail: dcdc@deltaww.com  
http://www.deltaww.com/dcdc  
P5  
Figure 12: Thermal derating curves  
DS_PACSR24012_05232017  
E-mail: dcdc@deltaww.com  
http://www.deltaww.com/dcdc  
P6  
Mechanical Drawing  
Mechanical Dimensions  
Pin Connection  
Pin  
ns  
Function  
1
2
ACL  
ACN  
3
BUS+  
BUS-  
4
5
PG  
6
SENSE-  
VOUT-  
VOUT+  
SENSE+  
TRIM  
7
8
9
10  
All dimensions in mm (inches)  
Tolerance:X.X±0.5 (X.XX±0.02)  
X.XX±0.25 ( X.XXX±0.010)  
Physical Outline  
Case Size  
Case Material  
Weight  
:
:
:
110.8x50.8x13.7mm (4.36”x2.0”x0.54”)  
AL6061+Plastic case  
240±10g  
Part Numbering System  
P
AC  
S
R
24  
012  
A
Form Factor  
Rated Input  
Voltage  
Number of  
Outputs  
Product Series Output Voltage  
Output  
Current  
Option Code  
AC -  
A Through hole  
S Screw hole(M3*0.5)  
S - Single  
R - Regular  
P-Module  
24V  
12.5A  
100VAC~240VAC  
Model List  
EFF @220VAC 100%  
LOAD  
Model Name  
Rate Input  
Output  
PACSR24012A  
PACSR24012S  
100VAC~240VAC  
100VAC~240VAC  
3.8A  
3.8A  
24V  
24V  
12.5A  
12.5A  
92%  
92%  
WARRANTY  
Delta offers a three (3) years limited warranty. Complete warranty information is listed on our web site or is available upon request from  
Delta.  
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any  
infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under  
any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice.  
DS_PACSR24012_05232017  
E-mail: dcdc@deltaww.com  
http://www.deltaww.com/dcdc  
P7  

相关型号:

PACSR24012A

24V Output AC/DC Converter, Module Package
DELTA

PACSR24021

24V Output AC/DC Converter, Module Package
DELTA

PACSR24021A

24V Output AC/DC Converter, Module Package
DELTA

PACSR24021S

24V Output AC/DC Converter, Module Package
DELTA

PACSR24SR24S

24V Output AC/DC Converter, Module Package
DELTA

PACSR28010

28V Output AC/DC Converter, Module Package
DELTA

PACSR28010A

28V Output AC/DC Converter, Module Package
DELTA

PACSR28010S

28V Output AC/DC Converter, Module Package
DELTA

PACSR28018

28V Output AC/DC Converter, Module Package
DELTA

PACSR28018A

28V Output AC/DC Converter, Module Package
DELTA

PACSR28018S

28V Output AC/DC Converter, Module Package
DELTA

PACSR48006

48V Output AC/DC Converter, Module Package
DELTA