DVPL0505S [DELTA]

HIGH RELIABILITY HYBRID DC-DC CONVERTERS; 高可靠性混合式DC -DC转换器
DVPL0505S
型号: DVPL0505S
厂家: DELTA ELECTRONICS, INC.    DELTA ELECTRONICS, INC.
描述:

HIGH RELIABILITY HYBRID DC-DC CONVERTERS
高可靠性混合式DC -DC转换器

转换器 DC-DC转换器
文件: 总13页 (文件大小:351K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
HIGH RELIABILITY HYBRID  
DC-DC CONVERTERS  
DESCRIPTION  
FEATURES  
High Reliability  
The DVPL series of high reliability DC-DC converters  
is operable over the full military (-55 °C to +125 °C)  
temperature range with no power derating.  
Operating at a nominal fixed frequency of 300 kHz,  
these regulated, non-isolated converters are  
optimized for low voltage point of load applications  
with high efficiency synchronous rectification, fast  
transient response, and power sequencing  
capability.  
Operates From 5V or 3.3V Input  
Adjustable Output Voltage, 0.8V to 3.4V  
Up to 5 Amps or 16W Output  
High Efficiency, Up to 97%  
Output Voltage Sequencing  
Output Voltage Tracking  
Operation Into a Pre-Biased Output  
Output Inhibit Control  
Low Output Noise  
These converters are designed and manufactured in  
a facility qualified to ISO9001 and certified to MIL-  
PRF-38534 and MIL-STD-883.  
NO Use of Optoisolators  
Over Current and Short Circuit Protection  
Precision Projection Welded Hermetic Package  
Meets MIL-STD-461C and MIL-STD-461D EMC  
Requirements When Used With VPT DC-DC  
Converters and EMI filters  
This product may incorporate one or more of the  
following U.S. patents:  
Additional Environmental Screening Available  
MIL-PRF-38534 Element Evaluated  
Components  
5,784,266  
5,790,389  
5,963,438  
5,999,433  
6,005,780  
6,084,792  
6,118,673  
Figure 1 – DVPL0505S DC-DC Converter  
(Not To Scale)  
Sales Information:  
Phone: (425) 353-3010  
Fax: (425) 353-4030  
11314 4th Avenue  
West, Suite 206  
Everett, WA 98204  
http://www.vpt-inc.com  
1X036DSB  
E-mail: vptsales@vpt-inc.com  
1
SPECIFICATIONS (TCASE = -55°C to +125°C, VIN = +3.3V, +5V ± 5%, Full Load, Unless Otherwise Specified)  
ABSOLUTE MAXIMUM RATINGS  
Input Voltage (Continuous)  
Input Voltage (Transient)  
5.5 VDC  
5.8 VDC  
Junction Temperature Rise to Case  
Storage Temperature  
+10°C  
-65°C to +150°C  
Output Power1  
16.5 Watts  
Lead Solder Temperature (10 seconds)  
Weight (Maximum)  
270°C  
Power Dissipation (Full Load, TCASE = +125°C) 1.3 Watt  
13 Grams  
DVPL0505S  
Units  
Parameter  
Conditions  
Min  
Typ  
Max  
STATIC  
VIN  
VIN  
Vout = 0.8V to 2.5V  
Vout = 2.6V to 3.3V  
Inhibited  
3.0  
4.0  
-
5.5  
5.5  
3
V
V
INPUT  
Voltage4  
-
-
mA  
mA  
V
Current  
Inhibit Pin Input4  
No Load  
60  
1.5  
Vin  
0
Inhibit Pin Open Circuit Voltage4  
UVLO Turn On4,6  
V
2.2  
2.0  
V
UVLO Turn Off4  
V
VOUT TCASE = 25°C  
-1.5  
-2.5  
0
Vout  
Vout  
+1.5  
+2.5  
16.5  
5
%Vout  
%Vout  
W
OUTPUT  
Voltage  
VOUT TCASE = -55°C to +125°C  
VOUT = 3.3V  
Power3,1  
Current3  
VOUT  
0
A
Ripple Voltage  
Load Regulation  
VOUT Full Load, 20Hz to 10MHz  
VOUT No Load to Full Load  
Vin = 5V, Vout = 3.3V  
Short Circuit  
35  
15  
96  
90  
mVp-p  
mV  
%
40  
EFFICIENCY  
93  
FAULT POWER DISSIPATION  
CAPACITIVE LOAD4  
3
5000  
350  
-
W
µF  
SWITCHING FREQUENCY  
CASE ISOLATION  
240  
100  
300  
-
kHz  
M  
kHrs  
500 VDC  
MTBF (MIL-HDBK-217F)  
AIF @ TC = 55°C  
800  
DYNAMIC  
Load Step Output Transient5  
Load Step Recovery2,5  
Turn On Delay  
VOUT  
100  
30  
250  
75  
6
mV  
Half Load to Full Load  
µSec  
mSec  
mVPK  
VOUT  
VIN = 0V to 5V  
Turn On Overshoot  
40  
VOLTAGE TRACKING  
Power-up  
100  
200  
300  
400  
2
mV  
mV  
Tracking Accuracy4  
Power-down  
At track pin  
Slew Rate4  
0.1  
10  
V/msec  
From Vin to tracking  
voltage applied  
Tracking Delay4  
ms  
Notes: 1. Dependant on output voltage. 2. Time for output voltage to settle within 1% of its nominal value.  
3. Derate linearly to 0 at 135°C. 4. Verified by qualification testing.  
5. With 100µF capacitor from Vin to Ground  
6. Vout not necessarily in regulation.  
1X036DSB  
2
BLOCK DIAGRAM  
Figure 2  
CONNECTION DIAGRAM  
2
1
4
6
+V OUT  
TRIM  
+VIN  
TRACK  
INH  
+
+VIN  
100uF  
LOAD  
-
7
5
R
5
COM  
COM  
Figure 3  
(Shown with recommended 100uF input capacitor)  
1X036DSB  
3
TYPICAL DISTRIBUTED APPLICATION  
DVHE2805S D C/DC CON VERT ER  
DVPL0505S DC /DC CONVERTER  
1
5
2
1
4
28V IN  
+V OUT  
+V OUT  
TRIM  
+V IN  
TRACK  
INH  
6
9
+S  
LOAD1  
5V  
2
6
LOAD2  
3.3V  
+
28 Vdc  
-
INH  
TRIM  
C
7
5
3
4
-S  
R
10  
5
IN COM  
OU T COM  
COM  
COM  
DVPL0505S DC /DC CONVERTER  
4
2
1
+V OUT  
+V IN  
TRACK  
INH  
6
5
LOAD3  
2.5V  
C
TRIM  
7
5
R
COM  
COM  
Figure 4  
TRACKING APPLICATION  
DVPL0505S DC /DC CONVERTER  
4
2
1
+V OUT  
+V IN  
TRACK  
INH  
6
5
LOAD1  
3.3V  
TRIM  
7
5
R
COM  
COM  
+
+VIN  
-
DVPL0505S DC /DC CONVERTER  
4
2
1
+V OUT  
+V IN  
TRACK  
INH  
6
5
LOAD2  
2.5V  
TRIM  
7
5
R
COM  
COM  
Figure 5  
1X036DSB  
4
INTERNAL CONNECTION DIAGRAMS  
2
+VIN  
15k  
INH  
7
20k  
OPTIONAL  
CAPACIT OR  
COM 5  
Figure 6 – Internal Inhibit Circuit and Recommended Drive  
Figure 7 – Internal Track Circuit  
(Shown with optional capacitor for turn-on delay)  
+VIN  
TRACK  
+VOUT  
TRACK TRACK  
DELAY SLEW  
TRACK  
SLEW  
Figure 8 – Track timing relations  
1X036DSB  
5
OUTPUT VOLTAGE TRIM  
+V OUT  
PIN 4  
The output voltage is set with an external  
resistor connected from Trim pin to GND  
pin. This resistor must have a tolerance of  
1% or less to achieve an accurate output  
voltage.  
30K  
TRIM  
Pin 6  
-
The default output voltage with the TRIM  
pin left open is 0.80V.  
5.1K  
+
R-TRIM  
210K  
+
-
0.7 V  
COM  
PIN 5  
DVPL0505S  
+VOUT (V)  
RTRIM ()  
0.8  
0.9  
1.0  
1.2  
1.5  
1.8  
1.9  
2.0  
2.5  
2.8  
3.0  
3.3  
3.4  
-
168RTRIM + 5.267*106  
Vo =  
205k  
99.9k  
47.4k  
24.9k  
15.9k  
13.9k  
12.4k  
7.25k  
5.40k  
4.44k  
3.30k  
2.98k  
210RTRIM +1.071*106  
5.267*106 1.071*106 *Vo  
RTRIM  
=
210*Vo 168  
Figure 9 – Output Voltage Trim  
1X036DSB  
6
EFFICIENCY PERFORMANCE CURVES (TCASE = 25°C, Full Load, Unless Otherwise Specified)  
VOUT = 3.3V  
VOUT = 2.5V  
VOUT =1.5V  
VOUT = 0.8V  
98  
96  
94  
92  
90  
88  
86  
84  
82  
0
1
2
3
4
5
Output Current (A)  
Figure 10 – DVPL0505S Vin=5.0V  
Efficiency (%) vs. Output Current (A)  
98  
96  
94  
92  
90  
88  
86  
84  
82  
0
1
2
3
4
5
Output Current (A)  
Figure 11 – DVPL0505S Vin=3.3V  
Efficiency (%) vs. Output Current (A)  
1X036DSB  
7
EMI PERFORMANCE CURVES (TCASE = 25°C, Full Load, Unless Otherwise Specified)  
Figure 12 – 5V input line, DVPL, CIN=100µF  
Figure 13 – 5V input line, DVMC and DVPL, CIN=100µF  
Figure 14- 28V input line, DVMC, DVHE and DVPL, CIN=100µF  
1X036DSB  
8
PACKAGE SPECIFICATIONS  
TOP VIEW  
SIDE VIEW  
PIN  
1
FUNCTION  
TRACK  
+V IN  
2
3
CASE  
4
+V OUT  
COM  
5
6
TRIM  
7
INHIBIT  
BOTTOM VIEW  
Figure 15 – Package and Pinout  
(Dimensional Limits are ±0.005” Unless Otherwise Stated)  
1X036DSB  
9
PACKAGE PIN DESCRIPTION  
Pin  
Function  
Description  
The output voltage will follow this pin. Used for output voltage sequencing or  
tracking. If not used, the Track pin should be connected to Vin.  
1
TRACK  
2
3
4
5
6
+V IN  
CASE  
+V OUT  
COM  
Positive Input Voltage Connection  
Case Connection  
Positive Output Voltage Connection  
Common Return Connection  
TRIM  
Trim pin sets output voltage with a resistor to Common  
Logic Low = Disabled Output. Connecting the inhibit pin to common causes  
converter shutdown.  
Logic High (open collector or open drain) = Enabled Output. Leave open if not  
used.  
7
INHIBIT  
1X036DSB  
10  
ENVIRONMENTAL SCREENING (100% Tested Per MIL-STD-883 as referenced to MIL-PRF-38534)  
Extended  
/ES  
HB  
/HB  
Class H  
/H  
Class K  
/K  
Standard  
(No Suffix)  
Screening  
MIL-STD-883  
Non-  
Destructive  
Bond Pull  
Method 2023  
Internal  
Visual  
Method 2017, 2032  
Internal Procedure  
Temperature  
Cycling  
Method 1010, Condition C  
Method 1010, -55°C to 125°C  
Constant  
Acceleration  
Method 2001, 3000g, Y1 Direction  
Method 2001, 500g, Y1 Direction  
PIND  
Method 2020, Condition A2  
Pre Burn-In  
Electrical  
100% at 25°C  
Method 1015, 320 hours at +125°C  
Method 1015, 160 hours at +125°C  
96 hours at +125°C  
Burn-In  
24 hours at +125°C  
Final  
Electrical  
MIL-PRF-38534, Group A1  
100% at 25°C  
Method 1014, Fine Leak, Condition A  
Method 1014, Gross Leak, Condition C  
Dip (1 x 10-3)  
Hermeticity  
Radiography  
Method 20123  
Method 2009  
External  
Visual  
Notes:  
1.  
2.  
3.  
100% R&R testing at –55°C, +25°C, and +125°C with all test data included in product shipment.  
PIND test Certificate of Compliance included in product shipment.  
Radiographic test Certificate of Compliance and film(s) included in product shipment.  
1X036DSB  
11  
ORDERING INFORMATION  
DVPL  
05  
05  
S
/HB  
-
XXX  
1
2
3
4
5
6
(1)  
(2)  
(3)  
Output Current  
(4)  
Nominal Input  
Voltage  
Product Series  
Number of Outputs  
DVPL  
05  
5 Volts  
05  
5 Amps  
S
Single  
(5)  
(6)  
Additional Screening  
Code  
Screening Code1,2  
None  
/ES  
/HB  
/H  
Standard  
Extended  
HB  
Class H  
Class K  
Contact Sales  
/K  
Notes:  
1.  
2.  
Contact the VPT Inc. Sales Department for availability of Class H (/H) or Class K (/K) qualified products.  
VPT Inc. reserves the right to ship higher screened or SMD products to meet lower screened orders at our  
sole discretion unless specifically forbidden by customer contract.  
Please contact your sales representative or the VPT Inc. Sales Department for more information  
concerning additional environmental screening and testing, different input voltage, output voltage,  
power requirement, source inspection, and/or special element evaluation for space or other higher  
quality applications.  
1X036DSB  
12  
SMD (STANDARD MICROCIRCUIT DRAWING) NUMBERS  
Standard Microcircuit  
Drawing (SMD)  
DVPL0505S Series  
Similar Part Number  
*T.B.D.  
DVPL0505S/H  
Do not use the DVPL0505S Series similar part number for SMD product acquisition. It is listed for  
reference only. For exact specifications for the SMD product, refer to the SMD drawing. SMD’s can be  
downloaded from the DSCC website at http://www.dscc.dla.mil/programs/smcr/. The SMD number  
listed above is for MIL-PRF-38534 Class H screening, standard gold plated lead finish, and no RHA  
(Radiation Hardness Assurance) level. Please reference the SMD for other screening levels, lead  
finishes, and radiation levels.  
CONTACT INFORMATION  
To request a quotation or place orders please contact your sales representative or the VPT Inc. Sales  
Department at:  
Phone:  
Fax:  
(425) 353-3010  
(425) 353-4030  
E-mail:  
vptsales@vpt-inc.com  
All information contained in this datasheet is believed to be accurate, however, no responsibility is assumed for possible errors  
or omissions. The products or specifications contained herein are subject to change without notice.  
1X036DSB  
13  

相关型号:

DVPL0505S-XXX

HIGH RELIABILITY HYBRID DC-DC CONVERTERS
DELTA

DVPL0505S/ES-XXX

HIGH RELIABILITY HYBRID DC-DC CONVERTERS
DELTA

DVPL0505S/H-XXX

HIGH RELIABILITY HYBRID DC-DC CONVERTERS
DELTA

DVPL0505S/HB-XXX

HIGH RELIABILITY HYBRID DC-DC CONVERTERS
DELTA

DVPL0505S/K-XXX

HIGH RELIABILITY HYBRID DC-DC CONVERTERS
DELTA

DVPL0505SES

HIGH RELIABILITY HYBRID DC-DC CONVERTERS
VPT

DVPL0505SH

HIGH RELIABILITY HYBRID DC-DC CONVERTERS
VPT

DVPL0505SK

HIGH RELIABILITY HYBRID DC-DC CONVERTERS
VPT

DVPL0510S

HIGH RELIABILITY HYBRID DC-DC CONVERTERS
VPT

DVPL0510SES

HIGH RELIABILITY HYBRID DC-DC CONVERTERS
VPT

DVPL0510SH

HIGH RELIABILITY HYBRID DC-DC CONVERTERS
VPT

DVPL0510SK

HIGH RELIABILITY HYBRID DC-DC CONVERTERS
VPT