Features
ꢀ
ꢀ
ꢀ
Switching capacity up to 25A.
PC board mounting and insert mounting available.
Suitable for automation system and automobile auxiliary etc.
Ordering Information
NVFM C Z 20
DC12V 1.5 b D
1
2
3
4
5
6
7
8
1 Part number:NVFM
5 Coil rated Voltage(V):DC:6,12,24,48
6 Coil power consumption:1.2:1.2W;1.5:1.5W
7 Terminalsꢀb: PCB type;a: plug in type
8 Coil transient suppression: D: with diode;
R: with resistant;.
2 Contact arrangement:A:1A (1.2W);C:1C(1.5W)
3 Enclosure:S: Sealed type;Z: Dust cover;
4 Contact Current:25:25A/14VDC;20:20A/14VDC
NIL: standard
Contact Data
Contact Arrangement
Contact Material
1AꢁSPSTNOꢂf1CꢁSPDT(B-M)ꢂ
AgꢀSnO2 AgNiꢃ AgꢀCdO
,
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
1Aꢀ25A/14VDCꢄ1Cꢀ20A/14VDC
350W
75VDC
አ50mꢅ
105
Max. Switching Current:25A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
Operation
life
Electrical
Mechanical
107
Coil Parameter
Pickup
voltage
VDC(max)
(70%of rated
voltage )
release
Coil voltage
VDC
Coil
resistance
ꢅ±10%
voltage
VDC(min)
(10% of rated
voltage)
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
Dash
numbers
Rated
Max.
6
7.8
30
120
480
1920
24
4.2
8.4
0.6
1.2
2.4
4.8
0.6
1.2
2.4
4.8
006-1200
012-1200
024-1200
048-1200
006-1500
012-1500
024-1500
048-1500
12
24
48
6
15.6
31.2
62.4
7.8
ꢆ10
ꢆ10
ꢆ7
ꢆ7
1.2
1.5
16.8
33.6
4.2
12
24
48
15.6
31.2
62.4
96
8.4
384
1536
16.8
33.6
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
143
www.dblectro.com
Item 7 of IEC255-5
N VF M
Operation condition
Insulation Resistance1)
Dielectric Strength 1)
100Mꢀ min (at 500VDC)
Between contacts
Between contact and coil
Item 6 of IEC255-5
Item 6 of IEC255-5
50Hz 500V
50Hz 1000V
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
100m/s2
11ms
IEC68-2-27 Test Ea
10~40Hz double amplitude 1.27mm IEC68-2-6 Test Fc
8N 4NꢀPC typeꢁ
235x2 3x0.5s
-40~85
85% (at 40)
18.5g
IEC68-2-21 Test Ua1
IEC68-2-20 Test Ta method 1
IEC68-2-3 Test Ca
Note: 1). ,When testing, coil terminals shall be connect , if coil transient suppression is installed in relay .
Qualification inspection:
Perform the qualification test as specified in the table ꢂ of IEC255-19-1 and minimum sample size 24.
Dimensions (Unit: mm)
mm
>àçÇá
0.8
1.4
2.1
2.4
2.5
2.7
3.2
4.5
4.8
5.5
6.3
6.4
8
0.031
0.055
0.083
0.094
0.098
0.106
0.126
0.177
0.189
0.127
0.248
0.252
0.315
0.354
0.374
0.453
0.551
0.591
0.610
0.905
1.024
nãîÜ>àç>ìòèÑ
na`>>ìòèÑ
Mounting (Bottom views)
9
9.5
11.5
14
15
15.5
23
Note: Footprint as shown above
is also available.
Wiring diagram (Bottom views)
26
Dimensions
NOTES 1).Dimensions are in millimeter.
2).Inch equivalents are given for general information only.
Reference Data
www.dblectro.com
相关型号:
©2020 ICPDF网 联系我们和版权申明