NT90THLCODC48VI [DBLECTRO]
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications; 适用于汽车,机械,电子设备,空调装置和家用电器应用型号: | NT90THLCODC48VI |
厂家: | DB LECTRO INC |
描述: | Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications |
文件: | 总5页 (文件大小:1284K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Qubec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
NT90T (T91)
NT90T (T91)
03001003503
E9930952E01
E160644 E233737
R2033977.06
Patent No. 99312549.2 02110881.1
NT90T2
32.4 27.5 28.0 32.4 27.5 20
Features
Small size, light weight. Low coil power consumption, heavycontact load. Strong anti-shock and anti-vibration, high
reliability, long life.
Suitable for automobile, machine, electronic equipment, air conditioner and householdappliances applications.
PC board mounting and direct insert mounting available.
Ordering Information
NT90T H L A S DC12V C B 0.9
1
2
3 4 5
6
7
8
9
1 Part number NT90T NT90T2
2 Load H:30A N:40A
6 Coil rated voltage(V) AC:12,24,110,120,220
DC:3,5,6,9,12,15,18,24,48,110
7 Contact material C: AgCdO S: AgSnO2 I: AgSnO2 In2O3
3 High NIL: Standard L: Low profile type
4 Contact arrangement A:1A B:1B C:1C
5 Enclosure S: Sealed type D: Dust cover
E: Covered O: Open type
8 Resist heat class B:130
9 Coil power consumption 0.6:0.6W 0.9:0.9W
NIL:2VA
F:155
Contact Data
Contact Arrangement
Contact Material
1A SPSTBNO
AgCdO AgSnO2 AgSnO2In2O3
1B SPSTNC
1C SPDT(B-M)
NO:30A/240VAC,14VDC;
NO:40A/250VAC,30VDC; NC:30A/250VAC,30VDC (0.9W)
NO:30A/277VAC;NC:20A/277VAC
NC:20A/240VAC;30A/14VDC
Contact Rating (resistive)
Motor load 2HP 250VAC 1.5HP 250V
Lamp load TV-5
Max. Switching Power
1100W 7200VA
Max. Switching Voltage
Contact Resistance or Voltage drop
110VDC 250VAC
Max. Switching Current:40A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
30m
105
Operation
Life
Electrical
Mechanical
107
Coil Parameter
AC Coil Parameter
Release
voltage
VAC(min)
(30%of
rated
Pick up
voltage
VAC(max)
(75%of
rated
Rated voltage
VAC
Rated
current
mA
Coil
resistance
10%
Operate Release
Dash
numbers
Coil
power
Time
ms
Time
ms
Rated
Max
voltage)
voltage)
012AC
024AC
110AC
120AC
220AC
12
24
15.6
31.2
143
156
286
187
95
27
9.0
18.0
82.5
90.0
165.0
3.6
7.2
120
110
120
220
20
2360
3040
13490
33.0
36.0
66.0
2VA
16.5
6.4
CAUTION: 1.The use of any coil voltage less than therated coil voltage will compromise the operation of therelay.
2.Pickup and release voltage are for test purposes onlyand are not to be used as design criteria.
Ningbo Huaguan Relay Corporation LTD.
NHG RELAYS
Coil Parameter
DC Coil Parameter
Release
voltage
VDC(min)
(10% of
rated
Pick up
voltage
VDC(max)
(75% of
rated
Coil voltage
Coil
resistance
10%
Coil
power
W
Operate
Time
ms
Release
Time
ms
V
Dash
numbers
Rated
Max.
voltage)
voltage)
003-900
005-900
006-900
009-900
012-900
015-900
018-900
024-900
048-900
110-900
3
5
6
3.9
6.5
7.8
11.7
15.6
19.5
23.4
31.2
62.4
143
10
28
40
2.25
3.75
4.50
6.75
9.00
10.25
13.50
18.00
36.00
82.50
0.3
0.5
0.6
0.9
1.2
1.5
1.8
2.4
4.8
11.0
9
90
12
15
18
24
48
110
160
250
360
640
2560
13445
0.9
15
10
003-600
005-600
006-600
009-600
012-600
015-600
018-600
024-600
048-600
110-600
3
5
6
3.9
6.5
7.8
11.7
15.6
19.5
23.4
31.2
62.4
143
15
42
60
135
240
375
540
960
3840
20167
2.25
3.75
4.50
6.75
9.00
10.25
13.50
18.00
36.00
82.50
0.3
0.5
0.6
0.9
1.2
1.5
1.8
2.4
4.8
11.0
9
0.6
15
10
12
15
18
24
48
110
CAUTION: 1.The use of any coil voltage less than therated coil voltage will compromise the operation of therelay.
2.Pickup and release voltage are for test purposes onlyand are not to be used as design criteria.
Operation condition
Insulation Resistance
1000M min (at 500VDC)
Item 7 of IEC255-5
Dielectric Strength
Between contacts
Between contact and coil
50Hz 1500V
50Hz 2500V
Item 6 of IEC255-5
Item 6 ofIEC255-5
Shock resistance
Vibration resistance
Terminalsstrength
Solderability
200m/s2
11ms
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua1&Ua2
IEC68-2-20 Test Ta method 1
10~55Hz double amplitude 1.5mm
10N
235
2
3
0.5s
Ambient Temperature
Relative Humidity
-55~100
85% (at 40
-55~125
)
IEC68-2-3 Test Ca
Mass
31g Low profile type
35g
Qualification inspection:
Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24.
NT90T (T91)
mm /inch
Dimensions
32.4Max.
1.275Max.
Max.
32.4
1.275max.
8
0.315
8
0.315
0.75
0.029
0.75
0.029
5.4
5.4
0.213
0.213
3-6.4 0.8
0.252 0.031
2-? 0.8
0.031
2- 0.8
0.031
2-0.8 1.5
0.031 0.059
2-0.8 1.5
0.031 0.059
1.2X1.2
0.047 0.047
1.2 1.2
0.047 0.047
NT90T
32.4Max.
1.275max.
3-0.8
3-0.8
6
0.031
7.7
0.031
0.303
12.3
0.484
32.4Max.
1.275max.
NT90T2
Dimensions
NC
NC
NC
NO
COM
COM
NT90T2
NT90T
Wiring diagram(Top view)
0.303
0.083
0.606
0.043
Wiring diagram(Bottom view)
0.1
NOTES 1).Dimensions are in millimeters.
Mounting (Bottom view)
2).Inch equivalents are given for general information only.
Ningbo Huaguan Relay Corporation LTD.
NHG RELAYS
Safety approvals
Safety approval
Load
UL&CUR
T V
CQC
NO:40A/240VAC 30A/277VAC
NC: 30A/240VAC 20A/277VAC
2HP 250VAC
1 12 HP 250VAC TV-5
HP:A 1HP/16AFLA/120VAC
2HP/12AFLA/240VAC
NO: 40A/240VAC 14VDC
NC: 30A/240VAC 14VDC
Insulation B-class
F-class
NO: 30A/240VAC
NC: 20A/240VAC
B 30LRA/10AFLA/120VAC
30LRA/10AFLA/240VAC
Insulation B-class
F-class
Reference Data
相关型号:
NT90THLCODC48VS
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications
DBLECTRO
NT90THLCODC5VC
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications
DBLECTRO
NT90THLCODC5VI
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications
DBLECTRO
NT90THLCODC5VS
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications
DBLECTRO
NT90THLCODC6VC
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications
DBLECTRO
NT90THLCODC6VI
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications
DBLECTRO
NT90THLCODC6VS
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications
DBLECTRO
NT90THLCODC9VC
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications
DBLECTRO
NT90THLCODC9VI
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications
DBLECTRO
NT90THLCODC9VS
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications
DBLECTRO
NT90THLCSAC110VCB0.6
Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high reliability, long life.
DBLECTRO
NT90THLCSAC110VCB0.9
Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high reliability, long life.
DBLECTRO
©2020 ICPDF网 联系我们和版权申明