MDU3C-100M [DATADELAY]

TRIPLE, HCMOS-INTERFACED FIXED DELAY LINE (SERIES MDU3C); TRIPLE , HCMOS ,接口固定的延时线(系列MDU3C )
MDU3C-100M
型号: MDU3C-100M
厂家: DATA DELAY DEVICES, INC.    DATA DELAY DEVICES, INC.
描述:

TRIPLE, HCMOS-INTERFACED FIXED DELAY LINE (SERIES MDU3C)
TRIPLE , HCMOS ,接口固定的延时线(系列MDU3C )

文件: 总4页 (文件大小:45K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
MDU3C  
Ò
TRIPLE, HCMOS-INTERFACED  
FIXED DELAY LINE  
(SERIES MDU3C)  
data  
3
delay  
inc.  
devices,  
PACKAGES  
FEATURES  
1
2
3
4
5
6
7
14  
VDD  
N/C  
O1  
N/C  
O2  
N/C  
O3  
I1  
N/C  
I2  
N/C  
I3  
N/C  
GND  
I1  
VDD  
1
3
5
7
14  
12  
10  
8
·
·
·
·
·
·
Three independent delay lines  
Fits standard 14-pin DIP socket  
Low profile  
13  
12  
11  
10  
9
I2  
I3  
O1  
Auto-insertable  
O3  
8
Input & outputs fully CMOS interfaced & buffered  
10 T2L fan-out capability  
GND  
O5  
MDU3C-xx  
DIP  
Military SMD  
MDU3C-xxA2 Gull-Wing  
MDU3C-xxB2 J-Lead  
MDU3C-xxMC2  
MDU3C-xxM Military DIP  
FUNCTIONAL DESCRIPTION  
PIN DESCRIPTIONS  
The MDU3C-series device is a 3-in-1 digitally buffered delay line. The  
signal inputs (I1-I3) are reproduced at the outputs (O1-O3), shifted in time  
by an amount determined by the device dash number (See Table). The  
delay lines function completely independently of each other.  
I1-I3  
O1-O3 Signal Outputs  
VDD +5 Volts  
GND Ground  
Signal Inputs  
SERIES SPECIFICATIONS  
DASH NUMBER SPECIFICATIONS  
·
·
·
·
Minimum input pulse width: 100% of total delay  
Output rise time: 8ns typical  
Supply voltage: 5VDC ± 5%  
Supply current: ICCL = 40ma typical  
ICCH = 60ma typical  
Operating temperature: 0° to 70° C  
Temp. coefficient of total delay: 300 PPM/°C  
Part  
Number  
Delay Per  
Line (ns)  
10 ± 2.0  
15 ± 2.0  
20 ± 2.0  
25 ± 2.0  
30 ± 2.0  
40 ± 2.0  
50 ± 2.5  
60 ± 3.0  
75 ± 3.7  
100 ± 5.0  
MDU3C-10  
MDU3C-15  
MDU3C-20  
MDU3C-25  
MDU3C-30  
MDU3C-40  
MDU3C-50  
MDU3C-60  
MDU3C-75  
MDU3C-100  
·
·
O1  
100%  
I1  
O2  
100%  
I2  
O3  
100%  
I3  
NOTE: Any dash number between 10 and 100  
not shown is also available.  
VCC  
GND  
Functional block diagram  
Ó1997 Data Delay Devices  
Doc #97039  
12/12/97  
DATA DELAY DEVICES, INC.  
3 Mt. Prospect Ave. Clifton, NJ 07013  
1
MDU3C  
APPLICATION NOTES  
Delay Devices if your application requires device  
testing at a specific input condition.  
HIGH FREQUENCY RESPONSE  
The MDU3C tolerances are guaranteed for input  
pulse widths and periods greater than those  
specified in the test conditions. Although the  
device will function properly for pulse widths as  
small as 100% of the total delay and periods as  
small as 200% of the total delay (for a symmetric  
input), the delays may deviate from their values at  
low frequency. However, for a given input  
POWER SUPPLY BYPASSING  
The MDU3C relies on a stable power supply to  
produce repeatable delays within the stated  
tolerances. A 0.1uf capacitor from VDD to GND,  
located as close as possible to the VDD pin, is  
recommended. A wide VDD trace and a clean  
ground plane should be used.  
condition, the deviation will be repeatable from  
pulse to pulse. Contact technical support at Data  
DEVICE SPECIFICATIONS  
TABLE 1: ABSOLUTE MAXIMUM RATINGS  
PARAMETER  
DC Supply Voltage  
Input Pin Voltage  
Storage Temperature  
Lead Temperature  
SYMBOL  
VDD  
VIN  
TSTRG  
TLEAD  
MIN  
-0.3  
-0.3  
-55  
MAX  
7.0  
VDD+0.3  
150  
UNITS NOTES  
V
V
C
300  
C
10 sec  
TABLE 2: DC ELECTRICAL CHARACTERISTICS  
(0C to 70C, 4.75V to 5.25V)  
PARAMETER  
SYMBOL  
MIN  
TYP  
MAX  
UNITS  
NOTES  
High Level Output Voltage  
VOH  
3.98  
4.4  
V
VDD = 5.0, IOH = MAX  
VIH = MIN, VIL = MAX  
VDD = 5.0, IOL = MAX  
VIH = MIN, VIL = MAX  
Low Level Output Voltage  
VOL  
0.15  
0.26  
V
High Level Output Current  
Low Level Output Current  
High Level Input Voltage  
Low Level Input Voltage  
Input Current  
IOH  
IOL  
VIH  
VIL  
IIH  
-4.0  
4.0  
mA  
mA  
V
V
mA  
3.15  
1.35  
0.10  
VDD = 5.0  
Doc #97039  
12/12/97  
DATA DELAY DEVICES, INC.  
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com  
2
MDU3C  
PACKAGE DIMENSIONS  
14  
12  
10  
8
7
Lead Material:  
Nickel-Iron alloy 42  
TIN PLATE  
14  
12  
3
10  
5
8
7
.410  
TYP.  
1
1
3
5
.280  
MAX.  
.780 MAX.  
.820 MAX.  
.290  
MAX.  
.320  
MAX.  
.020  
TYP.  
.015 TYP.  
.070 MAX.  
.130  
.010 .002  
±
.030  
±
.020 TYP.  
.018  
.200  
TYP.  
.018 TYP.  
.600 TYP.  
TYP.  
.300  
TYP.  
.350  
MAX.  
.600 .010  
±
MDU3C-xxM (Military DIP)  
MDU3C-xx (Commercial DIP)  
.020 TYP.  
.040  
TYP.  
.010 TYP.  
.040  
TYP.  
.020 TYP.  
12  
.050 TYP.  
14  
1
12  
3
10  
5
8
7
14  
1
10  
5
8
7
.320  
TYP.  
.270  
TYP.  
.430  
TYP.  
.270  
TYP.  
3
.090  
.200  
.600  
.300  
MAX.  
.110  
.200  
.350  
MAX.  
.110  
TYP.  
.050  
TYP.  
.600  
.790 MAX.  
.790 MAX.  
MDU3C-xxA2 (Commercial Gull-Wing)  
MDU3C-xxB2 (Commercial J-Lead)  
.020 TYP.  
.040  
.010 .002  
±
TYP.  
14 13 12 11 10  
9
8
.882  
.005  
.710 .590  
MAX.  
±
.005  
±
.007  
.005  
±
1
2
3
4
5
6
7
.090  
.100  
.280  
MAX.  
.050  
.010  
.600  
±
.780 .020  
±
MDU3C-xxMC2 (Military SMD)  
Doc #97039  
12/12/97  
DATA DELAY DEVICES, INC.  
3 Mt. Prospect Ave. Clifton, NJ 07013  
3
MDU3C  
DELAY LINE AUTOMATED TESTING  
TEST CONDITIONS  
INPUT:  
OUTPUT:  
Ambient Temperature: 25oC ± 3oC  
Supply Voltage (VDD): 5.0V ± 0.1V  
Load:  
Cload  
1 FAST-TTL Gate  
5pf ± 10%  
:
Input Pulse:  
High = 5.0V ± 0.1V  
Threshold: 2.5V (Rising & Falling)  
Low = 0.0V ± 0.1V  
Source Impedance:  
Rise/Fall Time:  
50W Max.  
5.0 ns Max. (measured  
between 0.5V and 4.5V )  
PWIN = 1.5 x Total Delay  
PERIN = 10 x Total Delay  
Pulse Width:  
Period:  
NOTE: The above conditions are for test only and do not in any way restrict the operation of the device.  
PRINTER  
COMPUTER  
SYSTEM  
REF  
PULSE  
GENERATOR  
OUT  
I1  
I2  
I3  
O1  
O2  
O3  
IN  
TIME INTERVAL  
COUNTER  
DEVICE UNDER  
TEST (DUT)  
TRIG  
TRIG  
Test Setup  
PERIN  
PWIN  
TRISE  
TFALL  
INPUT  
SIGNAL  
VIH  
4.5V  
2.5V  
0.5V  
4.5V  
2.5V  
0.5V  
VIL  
TRISE  
TFALL  
OUTPUT  
SIGNAL  
VOH  
2.5V  
2.5V  
VOL  
Timing Diagram For Testing  
Doc #97039  
12/12/97  
DATA DELAY DEVICES, INC.  
Tel: 973-773-2299 Fax: 973-773-9672 http://www.datadelay.com  
4

相关型号:

MDU3C-100MC2

TRIPLE, HCMOS-INTERFACED FIXED DELAY LINE (SERIES MDU3C)
DATADELAY

MDU3C-10A1

Active Delay Line, 3-Func, 1-Tap, True Output,
DATADELAY

MDU3C-10A2

TRIPLE, HCMOS-INTERFACED FIXED DELAY LINE (SERIES MDU3C)
DATADELAY

MDU3C-10B1

Active Delay Line, 3-Func, 1-Tap, True Output,
DATADELAY

MDU3C-10B2

TRIPLE, HCMOS-INTERFACED FIXED DELAY LINE (SERIES MDU3C)
DATADELAY

MDU3C-10M

TRIPLE, HCMOS-INTERFACED FIXED DELAY LINE (SERIES MDU3C)
DATADELAY

MDU3C-10MC2

TRIPLE, HCMOS-INTERFACED FIXED DELAY LINE (SERIES MDU3C)
DATADELAY

MDU3C-15

TRIPLE, HCMOS-INTERFACED FIXED DELAY LINE (SERIES MDU3C)
DATADELAY

MDU3C-15A1

Active Delay Line, 3-Func, 1-Tap, True Output,
DATADELAY

MDU3C-15A2

TRIPLE, HCMOS-INTERFACED FIXED DELAY LINE (SERIES MDU3C)
DATADELAY

MDU3C-15B1

Active Delay Line, 3-Func, 1-Tap, True Output,
DATADELAY

MDU3C-15B2

TRIPLE, HCMOS-INTERFACED FIXED DELAY LINE (SERIES MDU3C)
DATADELAY