Industrial  
Light Commercial  
Residential  
Double-throw safety switch  
Agricultural  
An economical means  
of transferring power  
Double-throw general-duty  
non-fusible safety switches  
Double-throw  
safety switches  
Door cannot be opened with  
the switch ON. Switch cannot  
be turned ON with door open  
(without operating interlock  
defeater)  
DT223URH-N  
Compact Design, 100A, 240V  
Double-throw, 240 Vac  
general-duty, non-fusible  
compact design  
Double-throw, 240 Vac  
general-duty, non-fusible,  
quick-make, quick-break  
design  
Eaton’s double-throw safety switches are used to transfer service from a normal power  
source to an alternate source, or to switch from one load circuit to another. The manually  
operated double-throw safety switch provides an economical means of transferring power.  
Eaton offers a full line of general-duty and heavy-duty double-throw safety switches.  
Specifications  
Suitable for use on a circuit  
capable of delivering not  
more than 100,000 rms  
symmetrical amperes when  
protected by Class R or J fuses  
(30–200A); R, T or J fuses  
(400A). Short-circuit rating  
is 10,000 rms symmetrical  
amperes when protected  
by any other overcurrent  
protective device  
Specifications  
30–100A  
30–400A  
Suitable for service entrance  
use with neutral kit installed  
Horsepower rated  
Suitable for use as a manu-  
Suitable for service entrance  
ally operated switch per 2005  
use with neutral kit installed  
NECArticle 702  
Suitable for use as a manually  
operated switch per 2005  
NEC Article 702  
ULlisted File No. E5239  
Double-break visible rotary  
blades; quick-make, quick-  
break operation  
Features  
UL listed File No. E5239  
Palm-fitting, visible  
Quick-make, quick-break  
operating mechanism  
DT224URK-NPS  
red handle  
Quick-Make, Quick-Break Design,  
200A, 240V.  
Tri-lingual nameplate  
Features  
NEMA3R enclosure with  
Double-Throw Compact Design  
side opening door  
Palm-fitting, visible  
NEMA 3R  
red handle  
Visible, embossed  
ON-OFF indication  
Ampere  
Rating  
Enclosure  
Rainproof  
Tri-lingual nameplate  
Main and  
Standby  
Catalog Number  
Heavy-duty  
General-duty  
Concentric knockouts on  
bottom endwall and sides  
NEMA 3R enclosure with  
side opening door  
Non-Fusible Two-Pole—240 Vac  
Eaton’s heavy-duty double-  
throw safety switches are  
Eaton’s general-duty double-  
throw safety switches are  
commonly applied in emergency  
power or generator applications  
to reduce or eliminate the costly  
impact of power loss from the  
typical source in residential,  
agricultural and light commer-  
cial markets. All general-duty  
double-throw safety switches  
are non-fusible and are available  
up to 400A.  
Non-Fusible  
Two-Pole  
30  
60ꢀ  
100ꢀ  
DT221URH  
DT222URH  
DT223URH  
Lockable door hasp  
ON  
OFF  
Visible, embossed red  
ON-OFF indication  
Two Sources or  
Two Loads  
designed for commercial and  
industrial applications. Fusible  
switches are available through  
600A, while non-fusible switches  
are manufactured up to 800A.  
The wiring configuration from  
the factory allows a single load  
to be supplied by a normal  
or alternate source; however,  
where necessary, the wiring can  
be field modified to allow two  
loads to be alternately supplied  
by a single power source.  
Lockable handle  
ON  
Tangential knockouts  
Three-point mounting  
(30–100A) on bottom end-  
wall; concentric knockouts on  
higher ratings, and sides and  
rear of 30–100A  
Non-Fusible Two-Pole, Three-Wire—240 Vac—Solid Neutral  
Factory-installed neutral  
(optional catalog numbers are  
available without a neutral)  
Non-Fusible  
30ꢀ  
60ꢀ  
100ꢀ  
DT221URH-N  
DT222URH-N  
DT223URH-N  
Two-Pole with  
Neutral  
ON  
OFF  
ON  
Two Sources or  
Two Loads  
S/N  
Terminals suitable for 60º  
or 75ºC Al or Cu wire  
Lockable door hasp  
Lockable handle  
Double-Throw Quick-Make, Quick-Break Design  
Rounded shroud  
A standby generator connected  
to a residential wiring system  
must be installed according to  
the National Electrical Code.�  
A double-throw switch must be  
installed to isolate and discon-  
nect wiring from normal utility  
lines so that generator-produced  
electricity is not back-fed  
Factory-installed neutral  
(optional catalog numbers are  
available without a neutral)  
Maximum  
Mechanical door interlock to  
prevent easy access when the  
switch is in the ON position  
NEMA 3R  
Enclosure  
Rainproof  
Horsepower Ratings  
Single-Phase  
Ampere  
Rating  
Main and  
Standby  
Heavy-duty double-throw  
240 Vac  
250 Vdc Catalog Number  
Three-point mounting  
(30–100A)  
safety switches are designed  
to accommodate a wide range  
of accessories that can be factory  
or field installed. Customized  
solutions, including key inter-  
locks, viewing windows and  
receptacles, are also available  
through Eaton’s Switching  
Device Flex Center.  
Suitable for use on a circuit  
capable of delivering  
not more than 10,000 rms  
symmetrical amperes  
Non-Fusible Two-Pole—240 Vac—250 Vdc  
30  
60  
100  
200  
400  
3
5
DT221URKPS  
DT222URKPS  
DT223URKPS  
DT224URKPS  
DT225URKPS  
Four-point mounting  
(200–400A)  
Non-Fusible  
Two-Pole  
Two Sources or  
Two Loads  
ON  
OFF  
ON  
10  
20  
15  
10  
20  
40  
50  
Terminals suitable for 60º  
or 75ºC Al or Cu wire on  
30–100A; 75ºC Al or Cu wire  
on higher ratings  
Compact size  
onto normal utility lines.  
Whether normal electrical  
Non-Fusible Two-Pole, Three-Wire—240 Vac—250 Vdc—Solid Neutral  
service is disrupted by severe  
weather conditions, accidents or  
other issues, an Eaton general-  
duty double-throw safety switch  
is a critical component in your  
standby generator applications.  
30  
60  
100  
200  
400  
3
5
DT221URK-NPS  
DT222URK-NPS  
DT223URK-NPS  
DT224URK-NPS  
DT225URK-NPS  
10  
20  
15  
10  
20  
40  
50  
Rounded shroud  
Non-Fusible  
Two-Pole with  
Neutral  
Two Sources or  
Two Loads  
ON  
OFF  
ON  
S/N  
2
3
EATON CORPORATION Double-throw safety switch  
EATON CORPORATION Double-throw safety switch  
Double-throw heavy-duty  
fusible safety switches  
Double-throw heavy-duty  
non-fusible safety switches  
DT363URK  
DT363FGK  
Double-throw Heavy-Duty Non-  
Fusible Safety Switch, 100A, 600V  
Double-throw Heavy-Duty Fusible  
Safety Switch, 100A, 600V  
Features  
Tangential knockouts  
(30–100A) on top and bottom  
endwall (bottom only on  
NEMA 3R); concentric knock-  
outs on higher ratings, and  
sides and rear of 30–100A  
Door cannot be opened  
Features  
Three-point mounting  
(30–100A)  
Suitable for use on a circuit  
Double-throw 240 and  
600 Vac heavy-duty, fusible  
Double-throw 240 and  
600 Vac heavy-duty,  
non-fusible  
with the switch ON.  
capable of delivering not more  
than 100,000 rms symmetrical  
amperes when protected by  
Class R or J fuses (30–200A);  
R, T or J fuses (400–800A).  
Short-circuit rating is 10,000  
rms symmetrical amperes  
when protected by any other  
overcurrent protective device  
Palm-fitting, visible red handle  
Palm-fitting, visible red handle  
Switch cannot be turned ON  
with door open (without oper-  
ating interlock defeater)  
Four-point mounting  
(200–800A)  
Tri-lingual nameplate  
Tri-lingual nameplate  
Specifications  
Side opening doors on  
all enclosures  
Side opening doors on  
all enclosures  
Terminals suitable for 60º  
or 75ºC Al or Cu wire on  
30–100A; 75ºC Al or Cu wire  
on higher ratings  
Specifications  
30–600A  
Suitable for use on a circuit  
Lockable door hasp  
Lockable handle  
capable of delivering not  
more than 100,000 rms sym-  
metrical amperes when pro-  
tected by Class R or J fuses  
(30–200A); R, T or J fuses  
(400–600A). Short-circuit rat-  
ing is 10,000 rms symmetrical  
amperes when protected by  
any other overcurrent protec-  
tive device  
30–800A  
Horsepower rated  
Clear line shield to prevent  
accidental contact with  
Visible, embossed red  
ON-OFF indication  
Horsepower rated  
Suitable for service entrance  
energized parts; probe holes  
enable line side testing  
without removing the shield  
use with neutral or ground  
lug kit installed  
Three-point mounting  
(30–100A)  
Rounded shroud  
Tangential knockouts  
Suitable for service entrance  
Double-break visible rotary  
blades; quick-make, quick-  
break operation  
(30–100A) on top and bot-  
tom endwall (bottom only on  
NEMA 3R); concentric knock-  
outs on higher ratings, and  
sides and rear of 30–100A  
use with neutral or ground  
lug kit installed  
Full range of accessories  
Suitable for use as a  
Four-point mounting  
(200–600A)  
Wiring configuration from  
Door cannot be opened  
with the switch ON; switch  
cannot be turned ON with  
door open (without operating  
interlock defeater)  
manually operated switch  
per 2005 NEC Article 702  
Suitable for use as a  
factory allows a single load  
to be supplied by a normal  
or alternate source; can be  
modified to allow two loads  
to be alternately supplied  
by a single power source  
manually operated switch per  
2005 NEC Article 702  
Terminals suitable for 60º  
or 75ºC Al or Cu wire on  
30–100A; 75ºC Al or Cu wire  
on higher ratings  
UL listed File No E5239  
Lockable door hasp  
UL listed File No. E5239  
Double-break visible rotary  
blades; quick-make, quick-  
break operation  
Lockable handle  
Rounded shroud  
Double-Throw 240Vac Heavy-Duty, Non-Fusible  
Visible, embossed red  
ON-OFF indication  
Full range of accessories  
Maximum Horsepower  
Ratings  
NEMA 1  
NEMA 3R  
Enclosure  
Rainproof  
Double-Throw 240Vac Heavy-Duty, Fusible  
Single-  
Phase  
Enclosure  
Indoor  
Three-Phase  
Ampere  
Rating  
Main  
Maximum Horsepower Ratings  
withTime-Delay Fuses  
NEMA 1  
NEMA 3R  
Ampere  
Enclosure Indoor Enclosure Rainproof  
Rating Main  
Catalog  
Catalog  
Number  
and Standby 240 Vac 240 Vac  
250 Vdc Number  
and  
Fuse Class  
Single-Phase Three-Phase  
Catalog  
Number  
Catalog  
Number  
Standby Provision  
240 Vac  
240 Vac  
250 Vdc  
Non-Fusible Two-Pole—240 Vac—250 Vdc  
Two-Pole—240 Vac—250 Vdc  
30  
3
5
DT221UGK  
DT222UGK  
DT223UGK  
DT224UGK  
DT225UGK  
DT226UGK  
ON  
Non-Fusible  
200  
60  
10  
20  
15  
10  
20  
40  
50  
H
15  
40  
DT224FGK  
DT224FRK  
OFF  
ON  
2-Pole  
Fusible  
Two-Pole  
Two Sources  
ON  
OFF  
ON  
Fusible  
Two-Pole  
Two Loads  
100  
200  
400  
600ꢀ  
OFF  
ON  
Two Sources or Two Loads  
ON  
DT224URK  
DT225URK  
Three-Pole—240 Vac—250 Vdc  
Non Fusible Three-Pole—240 Vac—250 Vdc  
30  
60  
100  
200  
400  
600ꢀ  
H
H
H
H
H
T
3
7-1/2  
15  
5
DT321FGK  
DT322FGK  
DT323FGK  
DT324FGK  
DT325FGK  
DT326FGK  
DT321FRK  
DT322FRK  
DT323FRK  
DT324FRK  
DT325FRK  
DT326FRK  
30  
3
10  
20  
5
DT321UGK  
DT322UGK  
DT323UGK  
DT324UGK  
DT325UGK  
DT326UGK  
DT327UGK  
10  
15  
15  
10  
20  
40  
50  
50  
60  
10  
20  
15  
10  
20  
40  
50  
50  
50  
50  
ON  
OFF  
Fusible  
Three-Pole  
Two Sources  
ON  
OFF  
ON  
Fusible  
Three-Pole  
Two Loads  
ON  
OFF  
ON  
ON  
OFF  
ON  
Non-Fusible  
3-Pole with Neutral  
Two Sources or Two Loads  
Non-Fusible  
3-Pole  
Two Sources or Two Loads  
30  
100  
200  
400  
600ꢀ  
800ꢀ  
800ꢀ  
40  
DT323URK  
DT324URK  
DT325URK  
ON  
60  
125  
50  
60  
125  
125  
125  
125  
S/N  
1
1ꢀ2  
Aꢀ  
Onlyꢀavailableꢀforꢀuseꢀwithꢀfast-actingꢀfuses.ꢀStandardꢀhpꢀratingꢀisꢀshown.  
DT327UGK-N  
Aꢀ  
Bꢀ  
Warning:ꢀSwitchꢀisꢀnotꢀapprovedꢀforꢀserviceꢀentrance.  
Field-installableꢀneutralꢀkitꢀisꢀnotꢀavailable.ꢀIfꢀaꢀneutralꢀisꢀrequired,ꢀorderꢀtheꢀcatalogꢀnumberꢀshownꢀinꢀtheꢀtableꢀwithꢀ“N”ꢀsuffix.  
Double-Throw 600Vac Heavy-Duty, Fusible  
Maximum Horsepower Ratings  
NEMA 1  
Enclosure  
Indoor  
NEMA 3R  
Enclosure  
Rainproof  
NEMA 4X Enclosure,  
Corrosion-Resistant  
Stainless Steel  
withTime-Delay Fuses  
Ampere  
Rating  
Main  
and  
Single-Phase  
Three-Phase  
Fuse Class  
480  
Vac  
600  
Vac  
480  
Vac  
600  
Vac  
250  
Vdc  
Catalog  
Number  
Catalog  
Number  
Catalog  
Number  
Standby Provision  
Three-Pole—600 Vac—250 Vdc  
30  
H
H
H
H
T
7-1/2  
20  
10  
25  
40  
50  
15  
20  
40  
50  
DT361FGK  
DT362FGK  
DT363FGK  
DT364FGK  
DT365FGK  
DT361FWK  
60  
30  
50  
DT362FWK  
DT363FWK  
DT364FWK  
DT365FWK  
Fusible  
Three-Pole  
Two Sources  
ON  
OFF  
ON  
Fusible  
Three-Pole  
Two Loads  
100  
200  
400  
30  
60  
125  
250  
75  
150  
350  
DT363FRK  
DT364FRK  
DT365FRK  
50  
4
5
EATON CORPORATION Double-throw safety switch  
EATON CORPORATION Double-throw safety switch  
Double-throw heavy-duty  
non-fusible safety switches  
Double-throw heavy-duty  
switching neutral safety switches  
Double-throw safety switches  
applied in emergency power  
or generator applications may  
require a switched neutral in lieu  
of a solid neutral. If the neutral  
of the generator is bonded  
to a grounding system at the  
generator, then a separately  
derived system (reference NEC  
250-20[D] and Exhibit 250.7) has  
been created and a switched  
Eaton non-fusible three-pole and  
four-pole double-throw safety  
switches 30–800A are UL listed  
for switching neutral application  
with the proper installation of  
the applicable switching neutral  
bonding kit shown in the  
Accessories section of this bro-  
chure. Each bonding kit comes  
with applicable materials, hard-  
ware, instruction sheet and  
Double-Throw 600Vac Heavy-Duty, Non-Fusible  
Maximum Horsepower Ratings  
Bonding kit schematic  
NEMA 12  
NEMA 1  
Enclosure  
Indoor  
NEMA 3R  
Enclosure  
Rainproof  
Enclosure  
Industrial,  
Dust-Tight  
NEMA 4X  
Single-phaseꢀapplicationsꢀrequiringꢀaꢀneutralꢀpoleꢀbondingꢀkit  
Enclosure, Corrosion-Resistant,  
Stainless Steel  
Ampere  
Rating  
Single-Phase  
Three-Phase  
Main and  
Standby  
Catalog  
Catalog  
Number  
Catalog  
Number  
Catalog  
Number  
480 Vac 600 Vac 480 Vac 600 Vac 480 Vdc Number  
Two-Pole—600 Vac—250 Vdc  
30  
7-1/2  
20  
10  
25  
50  
50  
5
DT261UGK  
DT262UGK  
DT263UGK  
DT264UGKꢀ  
DT265UGK  
DT266UGK  
Non-Fusible  
60  
10  
20  
40  
50  
50  
ON  
Two-Pole  
100  
200  
400  
600  
40  
OFF  
Two Sources or  
Two Loads  
neutral in the double-throw safety adhesive-backed wiring schematic.  
1
1
50  
DT264URKꢀ  
DT265URK  
DT266URK  
ON  
switch is required. The switching  
neutral is required to avoid the  
potential for backfeeding of the  
power that might occur if the  
safety switch neutral is also  
bonded. If the generator neutral  
is brought to the service where  
it is bonded and grounded, then  
a non-separately derived system  
has been created and a solid  
neutral must be used in the  
double-throw safety switch.  
Most double-throw safety  
switches in today’s market are  
provided with solid neutrals and  
are not UL listed for switching  
neutral application. The market,  
some utilities and local codes  
are requiring the ability to break  
or switch the neutral on three-  
and four-pole double-throw  
The bonding kits can only be  
used on non-fusible double-throw  
safety switches. When a bond-  
ing kit is applied to a three-pole  
switch, the switch becomes a  
single-phase switch with single-  
phase horsepower ratings.  
Three-Pole—600 Vac—250 Vdc  
4
30  
7-1/2  
20  
10  
25  
50  
50  
20  
30  
5
DT361UGK  
DT362UGK  
DT363UGK  
DT364UGK  
DT365UGK  
DT366UGK  
DT367UGKꢀ  
DT361URK  
DT362URK  
DT363URK  
DT364URK  
DT365URK  
DT366URK  
DT367URKꢀ  
DT361UDKꢀ  
DT362UDKꢀ  
DT363UDKꢀ  
DT364UDKꢀ  
DT365UDK  
DT361UWK  
DT362UWK  
DT363UWK  
DT364UWK  
DT365UWK  
Non-Fusible  
Three-Pole  
ON  
OFF  
4
60  
50  
60  
10  
20  
40  
50  
50  
50  
50  
4
100  
200  
400  
600  
800  
800  
40  
75  
100  
150  
350  
350  
350  
350  
Two Sources or  
Two Loads  
Bonding kit schematic  
ON  
4
50  
125  
250  
250  
250  
250  
4ꢀ5  
Three-phaseꢀapplicationsꢀrequiringꢀaꢀneutralꢀpoleꢀbondingꢀkit  
4
—ꢀ  
A double-throw safety switch  
with the appropriate bonding kit  
installed is suitable for service  
entrance use. Typically, a four-pole  
double-throw safety switch is not  
suitable for service entrance use;  
however, with the appropriate  
bonding kit installed, the four-  
pole switch is suitable for service  
entrance use as noted on the  
device publication of the product.  
Non-Fusible  
2ꢀ3  
2ꢀ3  
4
ON  
—ꢀ  
Three-Pole with Neutral  
4
OFF  
ON  
DT367UGK-N  
DT367URK-N  
—ꢀ  
Two Sources or  
Two Loads  
S/N  
2
Four-Pole—600 Vac—250 Vdc  
30  
7-1/2  
20  
10  
25  
50  
50  
20  
30  
5
DT461URK  
DT462URK  
DT463URK  
DT464URK  
DT465URK  
DT466URK  
DT467URK  
60  
50  
60  
10  
20  
40  
50  
50  
50  
Non-Fusible  
Four-Pole  
ON  
OFF  
ON  
100  
200  
400  
600  
800  
40  
75  
100  
150  
350  
350  
350  
Two Sources or  
Two Loads  
125  
250  
250  
250  
DT464UGK  
DT465UGK  
DT466UGK  
DT467UGK  
Switching neutral bonding kits  
can also be factory installed  
by Eaton’s unique Switching  
Device Flex Center. See the end  
of this brochure for additional  
information on the Flex Center.  
ꢀ2  
Six-Pole—600 Vac—250 Vdc  
30  
7-1/2  
20  
40  
10  
25  
50  
15  
50  
75  
30  
5
10  
20  
DT661URK  
DT662URK  
DT663URK  
switches with a UL listing for that  
capability. Three-pole switches  
are used for single-phase  
Notesꢀ NEC 702 application, separately derived system  
Non-Fusible  
ON  
OFF  
ON  
60  
60  
and service equipment.  
Six-Pole  
100  
100  
Two Sources or  
Two Loads  
Two sources with switched neutral,  
generator is a separately derived system.  
switching neutral applications,  
while four-pole switches are used  
for three-phase switching neutral  
applications. In many cases, three-  
and four-pole double-throw safety  
switches are being installed in  
the field with the left-most pole  
being used as the switching  
neutral, but the switch is not  
UL listed for that application.  
Proper installation is governed by interpretation of the NEC,  
applicable local codes and local utility requirements. Applicable  
sections of these codes and requirements should be  
referenced prior to installation.  
Aꢀ  
Bꢀ  
Cꢀ  
Dꢀ  
Eꢀ  
Rated 600 Vdc, 50 hp in addition to ratings shown in table.  
Warning: Switch is not approved for service entrance.  
Field-installable neutral kit is not available. If a neutral is required, order the catalog number shown in the table with “N” suffix.  
NEMAꢀ12ꢀenclosuresꢀ(30–800A)ꢀcanꢀbeꢀfieldꢀmodifiedꢀtoꢀmeetꢀNEMAꢀ3Rꢀrainproofꢀrequirementsꢀwhenꢀaꢀfactory-providedꢀdrainꢀholeꢀisꢀopened.  
Also available in 240 Vac, catalog number DT325UDK.  
Double-Throw Switching Neutral  
Safety Switch  
(upper switch base assembly  
is shown)  
6
7
EATON CORPORATION Double-throw safety switch  
EATON CORPORATION Double-throw safety switch  
1. DT200NK  
200A Neutral/Ground Kit  
4. DT100BK  
100A Switching Neutral  
7. DS200EK1  
Auxiliary Contact Kit  
1NO/1NC  
10. DS16CL  
30–60A Copper Lug Kit  
Bonding Kit  
Accessories, hubs and  
standard lug capacities  
2. DS250H2  
Plate Type Hub  
5. DS468GK  
8. DS16CP  
400–800A Ground Lug Kit  
Control Pole Kit  
3. DS26FK  
60A 600V R Fuse Adapter Kit  
6. DS050MH  
9. DS26JK  
Myers Hub  
60A J Fuse Adapter Kit  
Accessories  
Hubs  
1
5
9
2
3
4
Neutral, ground lug, control pole and auxiliary contact kits contain  
materials for one switch base. Copper lug, 60A J fuse and R fuse  
kits contain materials for one three-pole switch base. Switching neu-  
tral bonding and 400A J fuse kit contents are for one complete dou-  
ble-throw switch. Applicable accessories for a specific safety switch  
can also be found on the inside door publication of the switch  
Catalog Number DS900AP Adapter Kit permits installation of  
Group 1 hubs on 200A double-throw switches.  
PlateType Hubs  
For NEMA 3R Enclosures (Up to 200A)  
Group 1  
Group 2  
General-Duty, Heavy-Duty,  
Double-Throw through 100A  
General-Duty, Heavy-Duty,  
Double-Throw through 200A  
Conduit Size  
Catalog  
Number  
Conduit Size  
Catalog  
Number  
in Inches (mm)  
in Inches (mm)  
Description  
Catalog Number  
0.75ꢀ(19.1)  
1.00ꢀ(25.4)  
1.25ꢀ(31.8)  
1.50ꢀ(38.1)  
2.00ꢀ(50.8)  
DS075H1  
DS100H1  
DS125H1  
DS150H1  
DS200H1  
2.00ꢀ(50.8)  
2.50ꢀ(63.5)  
3.00ꢀ(76.2)  
—ꢀꢀꢀꢀꢀ—  
—ꢀꢀꢀꢀꢀ—  
DS200H2  
DS250H2  
DS300H2  
1
Neutral Kits/Ground Kits  
30–100A  
200A  
400AꢀNon-Fusible  
600AꢀNon-Fusible  
400–600AꢀFusible  
DT100NK  
DT200NK  
DT400NK  
DT600NK  
DS800NK  
6
7
8
MyersType Hubs  
1
Ground Lug Kits  
NEMA 3R (400A and Above)  
NEMA 4X (Stainless Steel) and 12  
2
30–100Aꢀ  
DS100GK  
DS200GK  
DS468GK  
200A  
Conduit Size  
Catalog  
Number  
400–800A  
in Inches (mm)  
3
0.50ꢀ(12.7)  
0.75ꢀ(19.1)  
1.00ꢀ(25.4)  
1.25ꢀ(31.8)  
1.50ꢀ(38.1)  
2.00ꢀ(50.8)  
2.50ꢀ(63.5)  
3.00ꢀ(76.2)  
3.50ꢀ(88.9)  
4.00ꢀ(101.6)  
5.00ꢀ(127.0)  
DS050MH  
DS075MH  
DS100MH  
DS125MH  
DS150MH  
DS200MH  
DS250MH  
DS300MH  
DS350MH  
DS400MH  
DS500MH  
Switching Neutral Bonding Kits  
30–100A,ꢀThree-Pole,ꢀFour-PoleꢀNon-Fusible DT100BK  
200A,ꢀThree-Pole,ꢀFour-PoleꢀNon-Fusible  
400A,ꢀThree-Pole,ꢀFour-PoleꢀNon-Fusible  
600A,ꢀThree-Pole,ꢀFour-PoleꢀNon-Fusible  
800A,ꢀThree-Pole,ꢀFour-PoleꢀNon-Fusible  
DT200BK  
DT400BK  
DT600BK  
DT800BK  
10  
1
Control Pole Kit  
30–800Aꢀ  
DS16CP  
1
Auxiliary Contact Kits  
1NO/1NC  
2NO/2NC  
DS200EK1  
DS200EK2  
Standard lug capacities  
1
Copper Lug Kits  
30–60Aꢀ  
100A  
DS16CL  
DS36CL  
Although certain lug capacities are larger than required, only mini-  
mum wire bending space is provided per the requirements noted in  
NEC Tables 373-6 (a) and (b) for respective ampere ratings.  
4
J Fuse Adapter Kits  
60Aꢀ  
400Aꢀ600V  
DS26JK  
DT400JK  
Minimum  
Wire Size  
Maximum  
Wire Size  
Wire  
Type  
Description  
4
R Fuse Adapter Kits  
30A  
#14  
#2  
Cu/Al  
Cu/Al  
Cu/Al  
Cu/Al  
Cu/Al  
Cu/Al  
Cu/Al  
Cu/Al  
Cu/Al  
Cu/Al  
60A  
#14  
#2  
30A,ꢀ240V  
DS12FK  
DS16FK  
DS26FK  
DS36FK  
DS46FK  
DS56FK  
100Aꢀ  
200A  
400Aꢀ  
#14  
#6  
#1/0  
30A,ꢀ600V;ꢀ60A,ꢀ240V  
60A,ꢀ600V  
250ꢀkcmil  
(2)ꢀ300ꢀkcmil  
(1)ꢀ750ꢀkcmil  
(1)ꢀ600ꢀkcmil  
(1)ꢀ750ꢀkcmil  
(2)ꢀ500ꢀkcmil  
(3)ꢀ500ꢀkcmil  
(2)ꢀ#1/0  
(1)ꢀ#1/0  
(1)ꢀ#2  
(1)ꢀ#1/0  
(2)ꢀ#250  
(3)ꢀ#250  
100A,ꢀ240–600V  
200A,ꢀ240–600V  
400A,ꢀ240V  
600AꢀFusible  
Lubricating Grease for Safety Switch  
Blades and Contacts  
Eachꢀkitꢀcontainsꢀthreeꢀ30ꢀccꢀtubesꢀofꢀ  
lubricatingꢀgrease.  
DSLUBEKIT  
600AꢀNon-Fusible  
800A  
Copper-Bodied Lugs  
30Aꢀ  
60A  
100Aꢀ  
200A  
400A  
600A  
#14  
#6  
Cu  
Cu  
Cu  
Cu  
Cu  
Cu  
Aꢀ  
Forꢀheavy-dutyꢀandꢀgeneral-dutyꢀquick-make,ꢀquick-break.  
Groundꢀbarꢀkitꢀisꢀnotꢀlistedꢀonꢀdeviceꢀpublications.  
Forꢀheavy-dutyꢀnon-fusible.  
#14  
#4  
Bꢀ  
Cꢀ  
Dꢀ  
#6  
#6  
#1/0  
(2)ꢀ#1/0  
#1/0  
250ꢀkcmil  
500ꢀkcmil  
(2)ꢀ500ꢀkcmil  
Forꢀheavy-dutyꢀfusible.  
8
9
EATON CORPORATION Double-throw safety switch  
EATON CORPORATION Double-throw safety switch  
Dimensions and weights  
Short-circuit ratings  
1. General-Duty NEMA 3R  
1
2
3
30–400A  
W
D
W
W
D
D
2. Heavy-Duty NEMA 1, 3R  
30–800A  
3. Heavy-Duty NEMA 12, 4X  
30–400A  
H
H
H
C
L
C
L
Note  
Contactꢀyourꢀ  
Eatonꢀsalesꢀofficeꢀforꢀ  
outlineꢀdrawingsꢀandꢀ  
mountingꢀdimensions.  
Short-Circuit Ratings Using Class R, T or J Fusing  
Where Applicable  
ClassꢀHꢀfuseꢀclipsꢀsuppliedꢀasꢀstandardꢀforꢀ30–600AꢀexceptꢀClassꢀTꢀforꢀ  
400Aꢀatꢀ600V,ꢀandꢀ600Aꢀatꢀ240V.ꢀRatedꢀatꢀ10,000ꢀrmsꢀsymmetricalꢀwhenꢀusingꢀ  
ClassꢀHꢀfuses.  
D2  
D2  
D2  
Double-Throw General-Duty, Non-Fusible, 240V,Two-Pole  
Solid Neutral, Quick-Make, Quick-Break Design  
Double-Throw General-Duty, Non-Fusible, 240V,Two-Pole  
Solid Neutral, Compact Design  
NotꢀapplicableꢀtoꢀtheꢀCompactꢀDesign.ꢀTheꢀCompactꢀDesignꢀisꢀsuitableꢀforꢀuseꢀ  
onꢀaꢀcircuitꢀcapableꢀofꢀdeliveringꢀnotꢀmoreꢀthanꢀ10,000ꢀrmsꢀsymmetricalꢀamperes.  
NEMA 3R  
NEMA 3R  
Dimensions in Inches (mm)  
Dimensions in Inches (mm)  
Ampere  
Rating  
Weight  
Ampere  
Rating  
Weight  
Depth (D2) Lbs (kg)  
Height (H)  
Width (W)  
Depth (D)  
Depth (D2) Lbs (kg)  
Height (H)  
Width (W)  
Depth (D)  
Voltage  
Ampere  
Rating  
Ratings  
Type 1  
30  
24.63ꢀ(625.6) 11.94ꢀ(303.3) 9.88ꢀ(251.0)  
24.63ꢀ(625.6) 11.94ꢀ(303.3) 9.88ꢀ(251.0)  
24.63ꢀ(625.6) 11.94ꢀ(303.3) 9.88ꢀ(251.0)  
5.38ꢀ(136.7)  
5.38ꢀ(136.7)  
5.38ꢀ(136.7)  
34ꢀ(15.4)  
34ꢀ(15.4)  
34ꢀ(15.4)  
30  
14.69ꢀ(373.1) 9.63ꢀ(244.6) 10.81ꢀ(274.6) 5.23ꢀ(132.8) 12ꢀ(5.4)  
14.69ꢀ(373.1) 9.63ꢀ(244.6) 10.81ꢀ(274.6) 5.23ꢀ(132.8) 12ꢀ(5.4)  
14.69ꢀ(373.1) 9.63ꢀ(244.6) 10.81ꢀ(274.6) 5.23ꢀ(132.8) 12ꢀ(5.4)  
Type 3R  
Type 12  
Type 4X  
60  
60  
30  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100kꢀatꢀ600  
100  
100  
60  
200  
400  
37.38ꢀ(949.5) 19.56ꢀ(496.8) 11.25ꢀ(285.8) 6.10ꢀ(154.9)  
53.81ꢀ(1366.8) 23.13ꢀ(587.5) 12.50ꢀ(317.5) 8.88ꢀ(225.6)  
80ꢀ(36.3)  
140ꢀ(63.6)  
100  
200  
400  
600  
800  
Double-Throw Heavy-Duty, Non-Fusible, 240V and 600V, Three-Pole  
NEMA 1, 3R  
NEMA 12, 4X Stainless Steel  
Dimensions in Inches (mm)  
Dimensions in Inches (mm)  
The Flex Center staff has over  
120 years of design, manufac-  
turing and industry experience,  
and has been providing solutions  
to our customers since 1998.  
While you may think that your  
power switching needs are  
unlike any other, chances are,  
the Flex Center staff has already  
“been there, done that.”  
Renewal parts  
Non-fusible switches  
Ampere Width  
Height  
(H)  
Depth  
(D)  
Depth  
(D2)  
Weight  
Width  
Height  
(H)  
Depth  
(D)  
Depth  
(D2)  
Weight  
Rating  
(W)  
Lbs (kg) (W)  
Lbs (kg)  
Replacement parts for a specific  
catalog number are shown on  
the inside door label (publica-  
tion) of the switch. Switch  
bases, fuse bases, line shields  
(fusible switches) and operating  
handles (400A and above) are  
typically available as applicable.  
For additional information,  
The UL listed short-circuit  
ratings for Eaton non-fusible  
switches are based on the  
30  
11.94  
(303.3)  
24.63  
(625.6)  
9.88  
(251.0)  
5.38  
(136.7)  
34  
(15.4)  
12.00  
(304.8)  
25.88  
(657.4)  
10.25  
(260.4)  
5.50  
(139.7)  
60  
(27.2)  
60  
11.94  
(303.3)  
24.63  
(625.6)  
9.88  
(251.0)  
5.38  
(136.7)  
34  
(15.4)  
12.00  
(304.8)  
25.88  
(657.4)  
10.25  
(260.4)  
5.50  
(139.7)  
60  
(27.2)  
switches being properly pro-  
tected by overcurrent protective  
devices. For applications that  
require a UL listed short-circuit  
rating of 10,000 rms symmetrical  
amperes or less, an Eaton non-  
fusible switch must be properly  
protected by any overcurrent  
protective device rated no greater  
than the ampere rating of the  
switch. For applications that  
require a UL listed short-circuit  
rating of greater than 10,000  
rms symmetrical amperes, an  
Eaton non-fusible switch must  
be properly protected by the  
appropriate class and size fusing  
noted on the switch publication.  
Otherwise, this non-fusible  
switch must be replaced with  
an Eaton fusible switch that uses  
the appropriate fusing required.  
100  
200  
400  
600  
800  
11.94  
24.63  
(625.6)  
9.88  
(251.0)  
5.38  
(136.7)  
34  
(15.4)  
12.00  
(304.8)  
25.88  
(657.4)  
10.25  
(260.4)  
5.50  
(139.7)  
60  
(27.2)  
(303.3)  
19.56  
(496.8)  
37.38  
(949.5)  
11.25  
(285.8)  
6.10  
(154.9)  
80  
(36.3)  
19.50  
(495.3)  
41.00  
(1041.4)  
11.63  
(295.4)  
6.48  
(164.6)  
105  
(47.6)  
For further information on  
refer to Renewal Parts Catalog  
RP00801001E.  
23.13  
(587.5)  
53.81  
(1366.8)  
12.50  
(317.5)  
7.25  
(184.2)  
140  
(63.6)  
23.00  
(584.2)  
57.50  
(1460.5)  
12.50  
(317.5)  
7.25  
(184.2)  
185  
(83.9)  
our customized solutions for  
harsh environments, safety  
and convenience, please refer  
to our Flex Center brochure  
SA00801002E or contact the  
Flex Center at 1-888-329-9272.  
24.13  
(612.9)  
63.31  
(1608.1)  
14.13  
(358.9)  
8.88  
(225.6)  
175  
(79.4)  
Flex center  
24.13  
(612.9)  
63.31  
(1608.1)  
14.13  
(358.9)  
8.88  
(225.6)  
175  
(79.4)  
Our Cleveland, TN, Switching  
Devices Flex Center is a solu-  
tions center that designs and  
modifies safety switches,  
enclosed circuit breakers and  
rotary disconnects for unique  
customer needs that are not  
met by standard products. The  
Flex Center is a one-of-a-kind  
operation that is capable of  
solving our customers’ issues,  
while our competition is content  
to offer their customers only  
catalog items.  
Double-Throw Heavy-Duty, Fusible, 240V and 600V,Three-Pole  
NEMA 1, 3R  
NEMA 12, 4X Stainless Steel  
Dimensions in Inches (mm)  
Dimensions in Inches (mm)  
Ampere Width  
Height  
(H)  
Depth  
(D)  
Depth  
(D2)  
Weight  
Width  
Height  
(H)  
Depth  
(D)  
Depth  
(D2)  
Weight  
Rating  
(W)  
Lbs (kg) (W)  
Lbs (kg)  
30  
11.94  
(303.3)  
36.63  
(930.4)  
9.88  
(251.0)  
5.38  
(136.7)  
44  
(20.0)  
12.00  
(304.8)  
39.81  
(1011.2)  
10.25  
(260.4)  
5.50  
(139.7)  
45  
(20.4)  
60  
11.94  
(303.3)  
36.63  
(930.4)  
9.88  
(251.0)  
5.38  
(136.7)  
44  
(20.0)  
12.00  
(304.8)  
39.81  
(1011.2)  
10.25  
(260.4)  
5.50  
(139.7)  
45  
(20.4)  
100  
200  
400  
600  
Safety switch short circuit rat-  
ings are applicable to AC only.  
11.94  
36.63  
(930.4)  
9.88  
(251.0)  
5.38  
(136.7)  
44  
(20.0)  
12.00  
(304.8)  
39.81  
(1011.2)  
10.25  
(260.4)  
5.50  
(139.7)  
45  
(20.4)  
(303.3)  
19.56  
(496.8)  
50.88  
(1292.4)  
11.25  
(285.8)  
6.10  
(154.9)  
95  
(43.1)  
19.56  
(496.8)  
55.63  
(1413.0)  
11.63  
(295.4)  
6.46  
(164.1)  
100  
(45.4)  
2
Safety switch I t and Ip values  
are identical to UL maximum  
25.38  
(644.7)  
74.75  
(1898.7)  
14.13  
(358.9)  
8.88  
(225.6)  
230  
(104.3)  
25.38  
(644.7)  
74.75  
(1898.7)  
14.13  
(358.9)  
8.92  
(226.6)  
260  
(117.9)  
2
acceptable I t and Ip values for  
the corresponding class fuse.  
27.44  
(697.0)  
86.13  
(2187.7)  
14.13  
(358.9)  
8.88  
(225.6)  
320  
(145.1)  
10  
11  
EATON CORPORATION Double-throw safety switch  
EATON CORPORATION Double-throw safety switch  
Eaton’s Electrical Sector is  
a global leader in power  
PowerChain solutions help  
enterprises achieve sustainable  
and competitive advantages  
through proactive management  
of the power system as a  
strategic, integrated asset  
throughout its life cycle,  
resulting in enhanced safety,  
greater reliability and energy  
efficiency. For more information,  
visit www.eaton.com/electrical.  
distribution, power quality,  
control and automation, and  
monitoring products. When  
combined with Eatons full-scale  
engineering services, these  
products provide customer-  
driven PowerChainE solutions  
to serve the power system  
needs of the data center,  
industrial, institutional, public  
sector, utility, commercial,  
residential, IT, mission critical,  
alternative energy and OEM  
markets worldwide.  
Eaton Corporation  
Electrical Sector  
1111 Superior Ave.  
Cleveland, OH 44114  
United States  
877-ETN-CARE (877-386-2273)  
Eaton.com  
PowerChain Management is a registered  
trademark of Eaton Corporation.  
© 2010 Eaton Corporation  
All Rights Reserved  
Printed in USA  
Publication No. BR00801002E / Z10432  
November 2010  
All other trademarks are property of their  
respective owners.  

相关型号:

DT222URH-N

An economical means of transferring power
DALLAS

DT222URK-NPS

An economical means of transferring power
DALLAS

DT222URKPS

An economical means of transferring power
DALLAS

DT223UGK

An economical means of transferring power
DALLAS

DT223URH

An economical means of transferring power
DALLAS

DT223URH-N

An economical means of transferring power
DALLAS

DT223URK-NPS

An economical means of transferring power
DALLAS

DT223URKPS

An economical means of transferring power
DALLAS

DT224FGK

An economical means of transferring power
DALLAS

DT224FRK

An economical means of transferring power
DALLAS

DT224UGK

An economical means of transferring power
DALLAS

DT224URK

An economical means of transferring power
DALLAS