CY7C9689A  
TAXI™-compatible HOTLink Transceiver  
encoders to improve its serial transmission characteristics.  
These encoded characters are then serialized, converted to  
NRZI, and output from two PECL-compatible differential trans-  
mission line drivers at a bit-rate of either 10 or 20 times the  
input reference clock in 8-bit (or 10-bit bypass) mode, or 12 or  
24 times the reference clock in 10-bit (or 12-bit bypass) mode.  
Features  
• Second-generation HOTLink® technology  
AMDAM7968/7969 TAXIchip-compatible  
8-bit 4B/5B or 10-bit 5B/6B NRZI encoded data transport  
10-bit or 12-bit NRZI pre-encoded (bypass) data  
transport  
Synchronous TTL parallel interface  
Embedded/bypassable 256-character Transmit and  
Receive FIFOs  
50- to 200-MBaud serial signaling rate  
Internal phase-locked loops (PLLs) with no external  
PLL components  
Dual differential PECL-compatible serial inputs and  
outputs  
The receive section of the CY7C9689A HOTLink accepts a  
serial bit-stream from one of two PECL compatible differential  
line receivers and, using a completely integrated PLL Clock  
Synchronizer, recovers the timing information necessary for  
data reconstruction. The recovered bit stream is converted  
from NRZI to NRZ, deserialized, framed into characters,  
4B/5B or 5B/6B decoded, and checked for transmission  
errors. The recovered 8- or 10-bit decoded characters are then  
written to an internal Receive FIFO, and presented to the  
destination host system.  
Compatiblewith fiber-optic modules and copper cables  
Built-In Self-Test (BIST) for link testing  
Link Quality Indicator  
Single +5.0V ±10%supply  
100-pin TQFP  
The integrated 4B/5B and 5B/6B encoder/decoder may be  
bypassed (disabled) for systems that present externally  
encoded or scrambled data at the parallel interface. With the  
encoder bypassed, the pre-encoded parallel data stream is  
converted to and from a serial NRZI stream. The embedded  
FIFOs may also be bypassed (disabled) to create a  
reference-locked serial transmission link. For those systems  
requiring even greater FIFO storage capability, external FIFOs  
may be directly coupled to the CY7C9689A through the  
parallel interface without the need for additional glue-logic.  
Functional Description  
The CY7C9689A HOTLink Transceiver is a point-to-point  
communications building block allowing the transfer of data  
over high-speed serial links (optical fiber, balanced, and unbal-  
anced copper transmission lines) at speeds ranging between  
50 and 200 MBaud. The transmit section accepts parallel data  
of selectable widths and converts it to serial data, while the  
receiver section accepts serial data and converts it to parallel  
data of selectable widths. Figure 1 illustrates typical connec-  
tions between two independent host systems and corre-  
sponding CY7C9689A parts. The CY7C9689A provides  
enhanced technology, increased functionality, a higher level of  
integration, higher data rates, and lower power dissipation  
over the AMD AM7968/7969 TAXIchip products.  
The TTL parallel I/O interface may be configured as either a  
FIFO (configurable for depth expansion through external  
FIFOs) or as a pipeline register extender. The FIFO configura-  
tions are optimized for transport of time-independent  
(asynchronous) 8- or 10-bit character-oriented data across a  
link. A Built-In Self-Test (BIST) pattern generator and checker  
allows for testing of the high-speed serial data paths in both  
the transmit and receive sections, and across the intercon-  
necting links.  
HOTLink devices are ideal for a variety of applications where  
parallel interfaces can be replaced with high-speed,  
point-to-point serial links. Some applications include intercon-  
necting workstations, backplanes, servers, mass storage, and  
video transmission equipment.  
The transmit section of the CY7C9689A HOTLink can be  
configured to accept either 8- or 10-bit data characters on each  
clock cycle, and stores the parallel data into an internal  
synchronous Transmit FIFO. Data is read from the Transmit  
FIFO and is encoded using embedded 4B/5B or 5B/6B  
Transmit  
Data  
Data  
Receive  
Serial Link  
Control  
Control  
Status  
CY7C9689A  
CY7C9689A  
Status  
Serial Link  
Data  
Transmit  
Receive  
Data  
Figure 1. HOTLink System Connections  
Cypress Semiconductor Corporation  
Document #: 38-02020 Rev. *C  
3901 North First Street  
San Jose, CA 95134  
408-943-2600  
Revised November 7, 2002  
CY7C9689A  
TAXI HOTLink Transceiver Logic Block Diagram  
RXDATA/RXCMD  
13  
CONTROL  
TXDATA/TXCMD  
TXCLK  
RX  
STATUS  
TX  
STATUS  
MODE  
RXCLK  
REFCLK  
10  
8
13  
3
4
Mode  
Control  
Output Register  
Output Register  
MUX  
Input Register  
Flags  
Mode  
Receive  
FIFO  
Flags  
Transmit  
FIFO  
CONTROL  
Transmit  
PLL Clock  
Multiplier  
CE  
TXEN  
RXEN  
TXHALT  
MUX  
TXRST  
RXRST  
RFEN  
TXBISTEN  
RXBISTEN  
RESET  
Pipeline Register  
MUX  
MODE  
RANGESEL  
SPDSEL  
Pipeline Register  
Receive  
Control  
State  
RXMODE[1:0]  
FIFOBYP  
EXTFIFO  
ENCBYP  
BYTE8/10  
TEST  
BIST LFSR  
4B/5B, 5B/6B Decoder  
Machine  
BIST LFSR  
4B/5B, 5B/6B Encoder  
Transmit  
Control  
State  
Deserializer  
Framer  
Clock  
Divider  
RXSTATUS  
LFI  
RXEMPTY  
RXHALF  
RXFULL  
Machine  
MUX  
Receive  
Clock/Data  
Recovery  
Bit Clock  
Serial Shifter  
Bit Clock  
TX STATUS  
TXEMPTY  
TXHALF  
Routing Matrix  
TXFULL  
Signal  
Validation  
DLB  
OUTA  
CURSETA  
INA  
INB  
A/B  
OUTB  
CURSETB  
CARDET  
Document #: 38-02020 Rev. *C  
Page 2 of 46  
CY7C9689A  
Pin Configuration  
100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76  
TEST  
1
2
3
75  
SPDSEL  
RANGESEL  
RFEN  
A/B  
74  
73  
72  
LFI  
TXFULL  
VSS  
DLB  
4
5
71  
70  
69  
68  
67  
66  
65  
64  
63  
62  
61  
60  
59  
58  
57  
56  
55  
54  
53  
52  
51  
CE  
VLTN  
6
TXHALF  
RXEN  
TXBISTEN  
RXCLK  
7
8
TXCLK  
RXRST  
VSS  
TXHALT  
RXFULL  
VSS  
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
21  
22  
23  
RXSC/D  
VDD  
REFCLK  
VSS  
VSS  
CY7C9689A  
VDD  
VDD  
VSS  
RXDATA[0]  
TXEMPTY  
RXDATA[1]  
TXCMD[1]  
VSS  
TXRST  
VDD  
TXEN  
RXHALF  
TXSC/D  
RXEMPTY  
TXDATA[0]  
RXDATA[11]/RXCMD[1]  
TXCMD[0]  
VDD  
TXDATA[9]/TXCMD[2]  
RXDATA[2]  
VSS  
RXMODE[1]  
RXMODE[0]  
24  
25  
RESET  
26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50  
Document #: 38-02020 Rev. *C  
Page 3 of 46  
CY7C9689A  
(
Pin Descriptions  
Pin  
Transmit Path Signals  
68 TXCLK  
Name  
I/O Characteristics  
Signal Description  
TTL clock input  
Internal Pull-up  
Transmit FIFO Clock.  
Used to sample all Transmit FIFO and related interface signals.  
44, 42, TXDATA[7:0] TTL input, sampled on Parallel Transmit DATA Input.  
40, 36,  
34, 32,  
30, 22  
TXCLKor REFCLKWhen selected (CE = LOW and TXEN = asserted), information on these inputs  
Internal Pull-up  
is processed as DATA when TXSC/D is LOW and ignored otherwise. When the  
encoder is bypassed (ENCBYP is LOW), TXDATA[7:0] functions as the least  
significant eight bits of the 10- or 12-bit pre-encoded transmit character.  
When the Transmit FIFO is enabled (FIFOBYP is HIGH), these inputs are  
sampled on the rising edge of TXCLK. When the Transmit FIFO is bypassed  
(FIFOBYP is LOW) these inputs are captured on the rising edge of REFCLK.  
54, 46 TXDATA[9:8]/ TTL input, sampled on Parallel Transmit DATA or COMMAND Input.  
TXCMD[2:3]  
TXCLKor REFCLKWhen selected, BYTE8/10 is HIGH, and the encoder is enabled (ENCBYP is  
Internal Pull-up  
HIGH), information on these inputs are processed as TXCMD[2:3] if TXSC/D is  
HIGH and ignored otherwise.  
When selected, BYTE8/10 is LOW, and the encoder is enabled (ENCBYP is  
HIGH), information on these inputs are processed as TXDATA[9:8] if TXSC/D  
is LOW and ignored otherwise.  
When the encoder is bypassed (ENCBYP is LOW), TXDATA[9:8] functions as  
the 9th and 10th bits of the 10- or 12-bit pre-encoded transmit character.  
When the Transmit FIFO is enabled (FIFOBYP is HIGH), these inputs are  
sampled on the rising edge of TXCLK. When the Transmit FIFO is bypassed  
(FIFOBYP is LOW), these inputs are captured on the rising edge of REFCLK.  
58, 56 TXCMD[1:0]  
TTL input, sampled on Parallel Transmit COMMAND Input.  
TXCLKor REFCLKWhen selected and the encoder is enabled (ENCBYP is HIGH), information on  
Internal Pull-up  
these inputs is processed as a COMMAND when TXSC/D is HIGH and ignored  
otherwise.  
When BYTE8/10 is HIGH and the encoder is bypassed (ENCBYP is LOW), the  
TXCMD[1:0] inputs are ignored.  
When BYTE8/10 is LOW and when the encoder is bypassed (ENCBYP is  
LOW), the TXCMD[1:0] inputs function as the 11th and 12th (MSB) bits of the  
12-bit pre-encoded transmit character.  
When the Transmit FIFO is enabled (FIFOBYP is HIGH), these inputs are  
sampled on the rising edge of TXCLK. When the Transmit FIFO is bypassed  
(FIFOBYP is LOW), these inputs are sampled on the rising edge of REFCLK.  
20  
TXSC/D  
TTL input, sampled on COMMAND or DATA input selector.  
TXCLKor REFCLKWhen selected, BYTE8/10 is HIGH, and the encoder is enabled (ENCBYP is  
Internal Pull-up  
HIGH), this input selects if the DATA or COMMAND inputs are processed. If  
TXSC/D is HIGH, the value on TXCMD[3:0] is captured as one of sixteen  
possible COMMANDs, and the data on the TXDATA[7:0] bits are ignored. If  
TXSC/D is LOW, the information on TXDATA[7:0] is captured as one of 256  
possible 8-bit DATA values, and the information on the TXCMD[3:0] bus is  
ignored.  
When BYTE8/10 is LOW and the encoder is enabled (ENCBYP is HIGH) this  
input selects if the DATA or COMMAND inputs are processed. If TXSC/D is  
HIGH, the information on TXCMD[1:0] is captured as one of four possible  
COMMANDs, and the information on the TXDATA[9:0] bits are ignored. If  
TXSC/D is LOW, the information on TXDATA[9:0] is captured as one of 1024  
possible 10-bit DATA values, and the information on the TXCMD[1:0] bus is  
ignored.  
When the encoder is bypassed (ENCBYP is LOW) TXSC/D is ignored  
Document #: 38-02020 Rev. *C  
Page 4 of 46  
CY7C9689A  
Pin Descriptions (continued)  
Pin  
18  
Name  
TXEN  
I/O Characteristics  
Signal Description  
TTL input, sampled on Transmit Enable.  
TXCLKor REFCLKTXEN is sampled on the rising edge of the TXCLK or REFCLK input and enables  
Internal Pull-up  
parallel data bus write operations (when selected). The device is selected when  
TXEN is asserted during a clock cycle immediately following one in which CE  
is sampled LOW.  
Depending on the level on EXTFIFO, the asserted state for TXEN can be active  
HIGH or active LOW. If EXTFIFO is LOW, then TXEN is active LOW and data  
is captured on the same clock cycle where TXEN is sampled LOW. If EXTFIFO  
is HIGH, then TXEN is active HIGH and data is captured on the clock cycle  
following any clock edge when TXEN is sampled HIGH.  
7
TXBISTEN  
TXRST  
TTL input,  
asynchronous  
Internal Pull-up  
Transmitter BIST Enable.  
When TXBISTEN is LOW, the transmitter generates a 511-character repeating  
sequence that can be used to validate link integrity. This 4B/5B BIST sequence  
is generated regardless of the state of other configuration inputs. The trans-  
mitter returns to normal operation when TXBISTEN is HIGH. All Transmit FIFO  
read operations are suspended when BIST is active.  
16  
TTL input, sampled on Reset Transmit FIFO.  
TXCLK↑  
When the Transmit FIFO is enabled (FIFOBYP is HIGH), TXEN is deasserted,  
Internal Pull-up  
CE is asserted (LOW), and TXRST is sampled LOW by TXCLK for seven cycles,  
the Transmit FIFO begins its internal reset process. The Transmit FIFO TXFULL  
flag is asserted and the host interface counter and address pointer are zeroed.  
This reset propagates to the serial transmit side, any remaining counters and  
pointers. The TXFULL flag is asserted until both sides of the Transmit FIFO  
have reset. While TXRST remains asserted, the Transmit FIFO remains in reset  
and the TXFULL output remains asserted.  
When the Transmit FIFO is bypassed (FIFOBYP is LOW), TXRST is ignored.  
9
TXHALT  
TXFULL  
TTL input, sampled on Transmitter Halt Control Input.  
TXCLK↑  
When TXHALT is asserted LOW, transmission of data is suspended and the  
Internal Pull-up  
HOTLink TAXI transmits SYNC characters. When TXHALT is deasserted HIGH,  
normal data processing proceeds.  
If the Transmit FIFO is enabled (FIFOBYP is HIGH), the interface is allowed to  
continue loading data into the Transmit FIFO while TXHALT is asserted.  
72  
Three-state TTL  
output, changes  
Transmit FIFO Full Status Flag.  
When the Transmit FIFO is enabled (FIFOBYP is HIGH) and its flags are driven  
following TXCLKor (CE is LOW), TXFULL is asserted when four or fewer characters can be written  
REFCLK↑  
to the HOTLink Transmit FIFO. If a Transmit FIFO reset has been initiated  
(TXRST was sampled asserted for a minimum of seven TXCLK cycles),  
TXFULL is asserted to enforce the full/unavailable status of the Transmit FIFO  
during reset.  
When the Transmit FIFO is bypassed (FIFOBYP is LOW), the TXFULL output  
changes after the rising edge of REFCLK. TXFULL is asserted when the trans-  
mitter is BUSY (not accepting a new data or command characters) and  
deasserted when new characters can be accepted.  
When the Transmit FIFO is bypassed and RANGESEL is HIGH or SPDSEL is  
LOW, TXFULL toggles at the character rate to provide a character rate  
reference control-indication since REFCLK is operating at twice of the data rate.  
The asserted state of this output (HIGH or LOW) is determined by the state of  
the EXTFIFO input. When EXTFIFO is LOW, TXFULL is active LOW. When  
EXTFIFO is HIGH, TXFULL is active HIGH.  
70  
TXHALF  
Three-state TTL  
output, changes  
following TXCLK↑  
Transmit FIFO Half-full Status Flag.  
When the Transmit FIFO is enabled (FIFOBYP is HIGH and CE is LOW)  
TXHALF is asserted when the HOTLink Transmit FIFO is half full (128  
characters is half full). If a Transmit FIFO reset has been initiated (TXRST was  
sampled asserted for a minimum of seven TXCLK cycles), TXHALF is asserted  
to enforce the full/unavailable status of the Transmit FIFO during reset.  
When the Transmit FIFO is bypassed (FIFOBYP is LOW), TXHALF remains  
deasserted, having no logical function.  
TXHALF is forced to the High-Z state only during a full-chipreset (i.e., while  
RESET is LOW).  
Document #: 38-02020 Rev. *C  
Page 5 of 46  
CY7C9689A  
Pin Descriptions (continued)  
Pin  
60  
Name  
I/O Characteristics  
Signal Description  
Transmit FIFO Empty Status Flag.  
When the Transmit FIFO is enabled (FIFOBYP is HIGH and CE is LOW),  
TXEMPTY  
Three-state TTL  
output, changes  
following TXCLKor TXEMPTY is asserted when the HOTLink Transmit FIFO has no data to forward  
REFCLK↑  
to the encoder. If a Transmit FIFO reset has been initiated (TXRST was sampled  
asserted for a minimum of seven TXCLK cycles), TXEMPTY is deasserted and  
remains deasserted until the Transmit FIFO reset operation is complete.  
When the Transmit FIFO is bypassed (FIFOBYP is LOW), TXEMPTY is  
asserted to indicate that the transmitter can accept data. TXEMPTYis also used  
as a BIST progress indicator when TXBISTEN is asserted.  
When TXBISTEN is asserted LOW, TXEMPTY becomes the transmit BIST-loop  
counter indicator (regardless of the logic state of FIFOBYP). In this mode  
TXEMPTY is asserted for one TXCLK or REFCLK period at the end of each  
transmitted BIST sequence.  
Note: During BIST operations, when the Transmit FIFO is enabled (FIFOBYP  
is HIGH), it is necessary to keep TXCLK operating, even though no data is  
loaded into the Transmit FIFO and TXEN is never asserted, to allow the  
TXEMPTY flag to respond to the BIST state changes.  
The asserted state of this output (HIGH or LOW) is determined by the state of  
the EXTFIFO input. When EXTFIFO is LOW, TXEMPTY is active LOW. When  
EXTFIFO is HIGH, TXEMPTY is active HIGH.  
If CE is sampled asserted (LOW), TXEMPTY is driven to an active state. If CE  
is sampled deasserted (HIGH), TXEMPTY is placed into a High-Z state.  
Receive Path Signals  
RXCLK  
8
Bidirectional TTL clock Receive Clock.  
Internal Pull-up When the Receive FIFO is enabled (FIFOBYP is HIGH), this clock is the  
Receive interface input clock and is used to control Receive FIFO read and  
reset, operations. When the Receive FIFO is bypassed (FIFOBYP is LOW), this  
clock becomes the recovered Receive PLL character clock output which runs  
continuously at the character rate.  
41, 43, RXDATA[7:0] Three-state TTL  
Parallel Receive DATA Outputs.  
45, 47,  
48, 53,  
59,61  
output, changes  
following RXCLK↑  
When the decoder is enabled (ENCBYP is HIGH), the low-order eight bits of  
the decoded DATA character are presented on the RXDATA[7:0] outputs.  
COMMAND characters, when they are received, do not disturb these outputs.  
When the decoder is bypassed, the low order eight bits of the non-decoded  
character are presented on the RXDATA[7:0] outputs.  
When the Receive FIFO is disabled (FIFOBYP is LOW), these outputs change  
on the rising edge of the RXCLK output. When the Receive FIFO is enabled  
(FIFOBYP is HIGH), these outputs change on the rising edge of RXCLK input.  
RXEN is the three-state control for RXDATA[7:0].  
31, 33 RXDATA[9:8]/ Three-state TTL  
Parallel Receive DATA or COMMAND Output.  
RXCMD[2:3]  
output, changes  
following RXCLK↑  
When BYTE8/10 is HIGH and the decoder is enabled (ENCBYP is HIGH) these  
outputs reflects the value for the most recently received RXCMD[2:3].  
When BYTE8/10 is LOW and the decoder is enabled (ENCBYP is HIGH) these  
outputs reflects the value for the most recently received RXDATA[9:8].  
When the decoder is bypassed (ENCBYP is LOW), RXDATA[9:8] functions as  
the 9th and 10th bits of the 10- or 12-bit non-decoded receive character.  
When the Receive FIFO is disabled (FIFOBYP is LOW), these outputs change  
on the rising edge of the RXCLK output. When the Receive FIFO is enabled  
(FIFOBYP is HIGH), these outputs change on the rising edge of the RXCLK  
input.  
RXEN is a three-state control for RXDATA[9:8]/RXCMD[2:3].  
Document #: 38-02020 Rev. *C  
Page 6 of 46  
CY7C9689A  
Pin Descriptions (continued)  
Pin  
Name  
I/O Characteristics  
Signal Description  
Parallel Receive COMMAND Outputs.  
When the decoder is enabled (ENCBYP is HIGH) these outputs reflect the value  
for the most recently received RXCMD[1:0].  
23, 29 RXDATA[11:10 Three-state TTL  
]/RXCMD[1:0]  
output, changes  
following RXCLK↑  
When BYTE8/10 is HIGH and the decoder is bypassed (ENCBYP is LOW),  
these outputs have no meaning and are driven LOW.  
When BYTE8/10 is LOW and the decoder is bypassed (ENCBYP is LOW),  
RXCMD[1:0] functions as the 11th and 12th (MSB) bits of the 12-bit  
non-decoded receive character.  
When the Receive FIFO is disabled (FIFOBYP is LOW), this output changes  
on the rising edge of the RXCLK output. When the Receive FIFO is enabled  
(FIFOBYP is HIGH), these outputs change on the rising edge of the RXCLK  
input.  
RXEN is a three-state control for RXCMD[1:0].  
69  
RXEN  
TTL input, sampled  
on RXCLK↑  
Internal Pull-up  
Receive Enable Input.  
RXEN is a three-state control for the parallel data bus read operations. RXEN  
is sampled on the rising edge of the RXCLK input (or output) and enables  
parallel data bus read operations (when selected). The device is selected when  
RXEN is asserted during an RXCLK cycle immediately following one in which  
CE is sampled LOW. The parallel data pins are driven to active levels after the  
rising edge of RXCLK. When RXEN is de-asserted (ending the selection) the  
parallel data pins are High-Z after the rising edge of RXCLK.  
Depending on the level on EXTFIFO, this signal can be active HIGH or active  
LOW. If EXTFIFO is LOW, then RXEN is active LOW. If EXTFIFO is HIGH, then  
RXEN is active HIGH. Data is delivered on the clock cycle following any clock  
edge when RXEN is active.  
65  
RXSC/D  
Three-state TTL  
output, changes  
following RXCLK↑  
COMMAND or DATA Output Indicator.  
When BYTE8/10 is HIGH and the decoder is enabled (ENCBYP is HIGH), this  
output indicates which group of outputs have been updated. If RXSC/D is HIGH,  
RXCMD[3:0] contains a new COMMAND. The DATA on the RXDATA[7:0] pins  
remain unchanged. If RXSC/D is LOW, RXDATA[7:0] contains a new DATA  
character. The COMMAND output on RXCMD[3:0] remain unchanged.  
When BYTE8/10 is LOW and the decoder is enabled (ENCBYP is HIGH), this  
output indicates which group of outputs have been updated. If RXSC/D is HIGH,  
RXCMD[1:0] contains a new COMMAND and the DATA on the RXDATA[9:0]  
remain unchanged. If RXSC/D is LOW, RXDATA[9:0] contains a new DATA  
character and the COMMAND output on RXCMD[1:0] remain unchanged.  
When the decoder is bypassed (ENCBYP is LOW) RXSC/D is not used and  
may be left unconnected.  
RXEN is a three-state control for RXSC/D.  
6
VLTN  
Three-state TTL  
output, changes  
following RXCLK↑  
Internal Pull-down  
Code Rule Violation Detected.  
VLTN is asserted in response to detection of a 4B/5B or 5B/6B character that  
does not meet the coding rules of these characters. When VLTN is asserted,  
the values on the output DATA and COMMAND buses remain unchanged.  
VLTN remains asserted for one RXCLK period.  
VLTN is used to report character mismatches when RXBISTEN is driven LOW.  
VLTN is driven LOW when the decoder is bypassed (ENCBYP is LOW).  
RXEN is a three-state control for VLTN.  
67  
RXRST  
TTL input, sampled on Receive FIFO Reset. Active LOW.  
RXCLK↑  
Internal Pull-up  
When the Receive FIFO is enabled (FIFOBYP is HIGH), RXEN is deasserted,  
CE is asserted (LOW), and RXRSTis sampled while asserted (LOW) by RXCLK  
for seven cycles, the Receive FIFO begins its internal reset process.  
Once the reset operation is started, the RXEMPTY flag is asserted and the  
interface counters and address pointer are zeroed. The reset operation  
proceeds to clear out the internal write pointers and counters. The RXEMPTY  
output remains asserted through the reset operation and remains asserted until  
new data is written to the Receive FIFO. While RXRST remains asserted, the  
Receive FIFO remains in reset and cannot accept received characters.  
When the Receive FIFO is bypassed (FIFOBYP is LOW), RXRST is ignored.  
Document #: 38-02020 Rev. *C  
Page 7 of 46  
CY7C9689A  
Pin Descriptions (continued)  
Pin  
Name  
I/O Characteristics  
Signal Description  
Receiver Discard Policy Mode Select.  
00ballows all characters to be written into the Receive FIFO or output to the  
24, 25 RXMODE[1:0] Static control input  
TTL levels  
Normally wired HIGH Receive data bus  
or LOW  
01bdiscards all JK or LM sync characters except the lastone of a string of  
sync characters. Single sync characters in a data stream are included in the  
data written into the Receive FIFO.  
1Xbdiscards all JK or LM sync characters. The data stream written into the  
Receive FIFO does not include sync characters.  
77  
73  
RXBISTEN  
TTL input,  
asynchronous  
Internal Pull-up  
Receiver BIST Enable. Active LOW.  
When LOW, the receiver is configured to perform a character-for-character  
match of the incoming data stream with a 511-character BIST sequence. The  
result of character mismatches are indicated on the VLTN pin. Completion of  
each 511-character BIST loop is accompanied by an assertion pulse on the  
RXFULL flag.  
The state of ENCBYP, FIFOBYP, and BYTE8/10 have no effect on BIST  
operation.  
RFEN  
TTL input,  
asynchronous  
Internal Pull-up  
Reframe Enable.  
Used to control when the framer is allowed to adjust the character boundaries  
based on detection of one or more framing characters in the data stream.  
When framing is enabled (RFEN is HIGH) the receive framer realigns the serial  
stream to the incoming 10-bit JK sync character (if BYTE8/10 is HIGH) or the  
12-bit LM sync character (if BYTE8/10 is LOW). Framing is disabled when  
RFEN is LOW. The deassertion of RFEN freezes the character boundary  
relationship between the serial stream and character clock. RFEN is an  
asynchronous input, sampled by the internal Receive PLL character clock.  
10  
RXFULL  
Three-state TTL  
output, changes  
following RXCLK↑  
Receive FIFO Full Flag.  
When the Receive FIFO is enabled (FIFOBYP is HIGH) and its flags are driven  
(CE is LOW), RXFULL is asserted when space is available for four or fewer  
characters to be written to the HOTLink Receive FIFO. If the RXCLK input is  
not continuous or the FIFO is accessed at a rate slower than data is being  
received, RXFULL may also indicate that some data has been lost because of  
FIFO overflow.  
When the Receive FIFO is bypassed (FIFOBYP is LOW), RXFULL is  
deasserted to indicate that valid data may be present. RXFULL is also used as  
a BIST progress indicator, and pulses once every pass through the 511  
character BIST loop.  
When RXBISTEN is asserted (LOW), RXFULL becomes the receive BIST loop  
progress indicator (regardless of the logic state of FIFOBYP). While RXBISTEN  
is asserted, RXFULL is asserted until the receiver detects the start of the BIST  
pattern. Then RXFULL is deasserted for the duration of the BIST pattern,  
pulsing asserted for one RXCLK period on the last symbol of each BIST loop.  
If 14 of 28 consecutive symbols are received in error, RXFULL returns to the  
asserted state until the start of a BIST pattern is again detected.  
The asserted state of this output (HIGH or LOW) is determined by the state of  
the EXTFIFO input. When EXTFIFO is LOW, RXFULL is active LOW. When  
EXTFIFO is HIGH, RXFULL is active HIGH.  
19  
RXHALF  
Three-state TTL  
output, changes  
following RXCLK↑  
Receive FIFO Half-full Flag.  
When the Receive FIFO is enabled (FIFOBYP is HIGH and CE is LOW)  
RXHALF is asserted when the HOTLink Receive FIFO is half full (128  
characters is half full). If a Receive FIFO reset has been initiated (RXRST was  
sampled asserted for a minimum of seven RXCLK cycles), RXHALF is  
deasserted to enforce the empty/unavailable status of the Receive FIFO during  
reset. If FIFOBYP is LOW, RXHALF remains deasserted having no logical  
function.  
RXHALF is forced to the High-Z state only during a full-chipreset (i.e., while  
RESET is LOW).  
Document #: 38-02020 Rev. *C  
Page 8 of 46  
CY7C9689A  
Pin Descriptions (continued)  
Pin  
21  
Name  
I/O Characteristics  
Signal Description  
RXEMPTY  
Three-state TTL  
output, changes  
following RXCLK↑  
Receive FIFO Empty Flag.  
When the Receive FIFO is enabled (FIFOBYP is HIGH) and its flags are driven  
(CE is LOW), RXEMPTY is asserted when the HOTLink Receive FIFO has no  
data to forward to the parallel interface. If a Receive FIFO reset has been  
initiated (RXRST was sampled asserted for a minimum of seven RXCLK  
cycles), RXEMPTY is asserted to enforce the empty/unavailable status of the  
Receive FIFO during reset.  
Any read operation occurring when RXEMPTY is asserted results in no change  
in the FIFO status, and the data from the last valid read remains on the RXDATA  
bus. When the Receive FIFO is bypassed but the decoder is enabled,  
RXEMPTY is used as a valid data indicator. When deasserted it indicates that  
valid data is present at the RXDATA or RXCMD outputs as indicated by  
RXSC/D. When asserted it indicates that a SYNC character (JK or LM) is  
present on the RXCMD output pins. When the Receive FIFO is bypassed  
(FIFOBYP is LOW), RXEMPTY is deasserted whenever data is ready.  
The asserted state of this output (HIGH or LOW) is determined by the state of  
the EXTFIFO input. When EXTFIFO is LOW, RXEMPTY is active LOW. When  
EXTFIFO is HIGH, RXEMPTY is active HIGH.  
Control Signals  
71  
CE  
TTL input sampled on Chip Enable Input. Active LOW.  
TXCLK, RXCLK, or When CE is asserted and sampled LOW by RXCLK, the Receive FIFO status  
REFCLK↑  
flags are driven to their active states. When this input is deasserted and sampled  
by RXCLK, the Receive FIFO status flags are placed in a High-Z state.  
When CE has been sampled LOW and RXEN changes from deasserted to  
asserted and is sampled by RXCLK, the RXSC/D, RXDATA[7:0], RXDATA[9:8]/  
RXCMD[2:3] and VLTN output drivers are enabled and go to their driven levels.  
These pins remain driven until RXEN is sampled deasserted.  
When the Transmit FIFO is enabled (FIFOBYP is HIGH), and CE is asserted  
and sampled by TXCLK, the Transmit FIFO status flags are driven to their active  
states. When this input is deasserted and sampled by TXCLK, the Transmit  
FIFO status flags are placed in a High-Z state.  
When the Transmit FIFO is bypassed (FIFOBYP is LOW), and CE is asserted  
and sampled by REFCLK, the Transmit FIFO status flags are driven to their  
active states. When this input is deasserted and sampled by REFCLK, the  
Transmit FIFO status flags are placed in a High-Z state.  
When the Transmit FIFO is enabled (FIFOBYP is HIGH), CE has been sampled  
LOW, and TXEN changes from deasserted to asserted and is sampled by  
TXCLK, the TXSC/D, TXDATA[7:0], TXDATA[9:8]/RXCMD[2:3], and  
TXCMD[1:0] inputs are sampled and passed to the Transmit FIFO. These inputs  
are sampled on all consecutive TXCLK cycles until TXEN is sampled  
deasserted.  
When the Transmit FIFO is bypassed (FIFOBYP is LOW), CE has been  
sampled LOW, and TXEN changes from deasserted to asserted and is sampled  
by REFCLK, the TXSC/D, TXDATA[7:0], TXDATA[9:8]/RXCMD[2:3], and  
TXCMD[1:0] inputs are sampled and passed to the encoder or serializer as  
directed by other control inputs. These inputs are sampled on all consecutive  
REFCLK cycles until TXEN is sampled deasserted.  
12  
75  
REFCLK  
SPDSEL  
TTL clock input  
PLL Frequency Reference Clock.  
This clock input is used as the timing reference for the transmit and receive  
PLLs. When the Transmit FIFO is bypassed (FIFOBYP is HIGH), REFCLK is  
also used as the clock for the parallel transmit interface.  
Static control input  
TTL levels  
Speed Select.  
Used to select from one of two operating serial rates for the CY7C9689A. When  
Normally wired HIGH SPDSEL is HIGH, the signaling rate is between 100 and 200 MBaud. When  
or LOW  
LOW, the signaling rate is between 50 and 100 MBaud. Used in combination  
with RANGESEL and BYTE8/10 to configure the VCO multipliers and dividers.  
Document #: 38-02020 Rev. *C  
Page 9 of 46  
CY7C9689A  
Pin Descriptions (continued)  
Pin  
74  
Name  
I/O Characteristics  
Signal Description  
RANGESEL  
Static control input  
TTL levels  
Range Select.  
Selects the proper prescaler for the REFCLK input. If RANGESEL is LOW, the  
Normally wired HIGH REFCLK input is passed directly to the Transmit PLL clock multiplier. If  
or LOW  
RANGESEL is HIGH, REFLCK is divided by two before being sent to the  
Transmit PLL multiplier.  
When the Transmit FIFO is bypassed (FIFOBYP is LOW), with RANGESEL  
HIGH or SPDSEL LOW, TXFULL toggles at half the REFCLK rate to provide a  
character rate indication, and to show when data can be accepted.  
51  
28  
RESET  
Asynchronous  
TTL input  
Master Reset for Internal Logic.  
Pulsed LOW for one or more REFCLK cycles.  
FIFOBYP  
Static control input  
TTL levels  
FIFO Bypass Enable.  
When asserted, the Transmit and Receive FIFOs are bypassed. In this mode  
Normally wired HIGH TXCLK is not used. Instead all transmit data must be synchronous to REFCLK.  
or LOW  
Transmit FIFO status flags are synchronized to REFCLK. All received data is  
synchronous to RXCLK output. Receive FIFO status flags are synchronized to  
RXCLK (the recovered Receive PLL character clock).  
When not asserted, the Transmit and Receive FIFOs are enabled. In this mode  
all Transmit FIFO writes are synchronized to TXCLK, and all Receive FIFO  
reads are synchronous to the RXCLK input.  
50  
BYTE8/10  
Static control input  
TTL levels  
8/10-bit Parallel Data Size Select.  
When set for 8-bit data (BYTE8/10 is HIGH) and the encoder is enabled  
Normally wired HIGH (ENCBYP is HIGH), 8-bit DATA characters and 4-bit COMMAND characters are  
or LOW  
captured at the TXDATA[7:0] or TXCMD[3:0] inputs (selected by the TXSC/D  
input) and passed to the Transmit FIFO (if enabled) and encoder. Received  
characters are decoded, passed through the Receive FIFO (if enabled) and  
presented at either the RXDATA[7:0] or RXCMD[3:0] outputs and indicated by  
the RXSC/D output.  
When set for 8-bit data (BYTE8/10 is HIGH) and the encoder is bypassed  
(ENCBYP is LOW), the internal data paths are set for 10-bit characters. Each  
received character is presented to the Receive FIFO (if enabled) and is passed  
to the RXDATA[9:0] outputs.  
When set for 10-bit data (BYTE8/10 is LOW) and the encoder is enabled  
(ENCBYP is HIGH), 10-bit DATA characters and 2-bit COMMAND characters  
are captured at the TXDATA[9:0] or TXCMD[1:0] inputs (selected by the  
TXSC/D input) and passed to the Transmit FIFO (if enabled) and encoder.  
Received characters are decoded, passed through the Receive FIFO (if  
enabled) and presented at either the RXDATA[9:0] or RXCMD[1:0] outputs and  
indicated by the RXSC/D output.  
When set for 10-bit data (BYTE8/10 is LOW) and the encoder is bypassed  
(ENCBYP is LOW), the internal clock data paths are set for 12-bit characters.  
Each received character is presented to the Receive FIFO (if enabled) and is  
passed to the RXDATA[9:0] and the RXCMD[1:0] outputs.  
49  
EXTFIFO  
Static control input  
TTL levels  
External FIFO Mode.  
EXTFIFO modifies the active state of the RXEN and TXEN inputs and the timing  
Normally wired HIGH of the Transmitter and Receiver data buses. When configured for external  
or LOW  
FIFOs (EXTFIFO is HIGH), TXEN is assumed to be driven by the empty flag of  
an attached CY7C42X5 FIFO, and RXEN is assumed to be driven by the almost  
full flag of an attached CY7C42X5 FIFO. In this mode the active data transition  
is in the clock following the clock edge that enablesthe data bus.  
When not configured for external FIFOs (EXTFIFO is LOW), TXEN is assumed  
to be driven as a pipeline register and RXEN is assumed to be driven by a  
controller for a pipeline register. In this mode the active data transition is within  
the same clock as the clock edge that enablesthe data bus.  
EXTFIFO also modifies the output state of the Receive and Transmit FIFO flags.  
When configured for external FIFOs (EXTFIFO is HIGH), the Full and Empty  
FIFO flags are active HIGH (the Half full flag is always active LOW). When not  
configured for external FIFOs (EXTFIFO is LOW), all of the FIFO flags are active  
LOW.  
Document #: 38-02020 Rev. *C  
Page 10 of 46  
CY7C9689A  
Pin Descriptions (continued)  
Pin  
27  
Name  
I/O Characteristics  
Signal Description  
Enable Encoder Bypass Mode.  
When asserted, both the encoder and decoder are bypassed. Data is trans-  
ENCBYP  
Static control input  
TTL levels  
Normally wired HIGH mitted without 4B/5B or 5B/6B encoding (but with NRZI encoding), LSB first.  
or LOW  
Received data are presented as parallel characters to the parallel interface  
without decoding.  
When deasserted, data is passed through both the encoder in the Transmit path  
and the decoder in the Receive path.  
Analog I/O and Control  
89, 90, OUTA± PECL compatible  
Differential Serial Data Outputs.  
81, 82  
OUTB±  
differential output  
These PECL-compatible differential outputs are capable of driving terminated  
transmission lines or commercial fiber-optic transmitter modules. To minimize  
the power dissipation of unused outputs, the outputs should be left unconnected  
and the associated CURSETA or CURSETB should be connected to VDD  
.
94, 93, INA±  
PECL compatible  
differential input  
Differential Serial Data Inputs.  
86, 85  
INB±  
These inputs accept the serial data stream for deserialization and decoding.  
Only one serial stream at a time may be fed to the receive PLL to extract the  
data content. This stream is selected using the A/B input.  
97  
CURSETA  
CURSETB  
CARDET  
Analog  
Analog  
Current-set Resistor Input for OUTA±.  
A precision resistor is connected between this input and a clean ground to set  
the output differential amplitude and currents for the OUTA± differential driver.  
78  
Current-set Resistor Input for OUTB±.  
A precision resistor is connected between this input and a clean ground to set  
the output differential amplitude and currents for the OUTB± differential driver.  
100  
PECL input,  
Carrier Detect Input.  
asynchronous  
Used to allow an external device to signify a valid signal is being presented to  
the high-speed PECL input buffers, as is typical on an Optical Module. When  
CARDET is deasserted LOW, the LFI indicator asserts LOW signifying a Link  
Fault. This input can be tied HIGH for copper media applications.  
2
3
A/B  
LFI  
Asynchronous TTL  
input  
Input A or Input B Selector.  
When HIGH, input INA± is selected, when LOW, INB± is selected.  
TTL output, changes Link Fault Indication Output. Active LOW.  
following RXCLK↑  
LFI changes synchronous with RXCLK. This output is driven LOW when the  
serial link currently selected by A/B is not suitable for data recovery. This could  
be because:  
Serial Data Amplitude is below acceptable levels  
Input transition density is not sufficient for PLL clock recovery  
Input Data stream is outside an acceptable frequency range of operation  
CARDET is LOW  
5
DLB  
Asynchronous TTL  
input  
Diagnostic Loop Back Selector.  
When DLB is LOW, LOOP Mode is OFF. Output of the transmitter shifter is  
routed to both OUTA± and OUTB± and the serial input selected by A/B is routed  
to the receive PLL for data recovery.  
When DLB is HIGH, Diagnostic Loopback is Enabled. Output of the transmitter  
serial data is routed to the receive PLL for data recovery. Primarily used for  
System Diagnostic test. The serial inputs are ignored and OUTA± and OUTB±  
are both active.  
1
TEST  
Asynchronous TTL  
input normally wired  
HIGH  
Test Mode Select.  
Used to force the part into a diagnostic test mode used for factory ATE test. This  
input must be tied HIGH during normal operation.  
Power  
80, 87, VDDA  
88, 95,  
Power for PECL-compatible I/O signals and internal circuits.  
96, 98  
Document #: 38-02020 Rev. *C  
Page 11 of 46  
CY7C9689A  
Pin Descriptions (continued)  
Pin  
Name  
I/O Characteristics  
Signal Description  
76, 79, VSSA  
83, 84,  
91, 92,  
99  
Ground for PECL-compatible I/O signals and internal circuits.  
14, 17, VDD  
35, 55,  
62, 64  
Power for TTL I/O signals and internal circuits.  
Ground for TTL I/O signals and internal circuits.  
4,11, VSS  
13, 15,  
26, 37,  
38, 39,  
52, 57,  
63, 66  
When configured for synchronous operation, the transmit  
CY7C9689A HOTLink Operation  
interface is clocked by REFCLK and operates synchronous to  
the internal character and bit-stream clocks. The input register  
can be written at either 1/10 or 1/12 the serial bit rate. This  
interface can be clocked at up to 40 MHz when configured for  
8-bit data width, and up to 33 MHz when configured for 10-bit  
data bus width. Actual clock rate depends on data rate as well  
as RANGESEL and SPDSEL logic levels.  
Overview  
The CY7C9689A is designed to move parallel data across  
both short and long distances with minimal overhead or host  
system intervention. This is accomplished by converting the  
parallel characters into a serial bit-stream, transmitting these  
serial bits at high speed, and converting the received serial bits  
back into the original parallel data format.  
Both asynchronous and synchronous interface operations  
support user control over the logical sense of the FIFO status  
flags. Full and empty flags on both the transmitter and receiver  
can be active HIGH or active LOW. This facilitates interfacing  
with existing control logic or external FIFOs with minimal or no  
external glue logic.  
The CY7C9689A offers a large feature set, allowing it to be  
used in a wide range of host systems. Some of the configu-  
ration options are  
AMD TAXIchip 4B/5B- and 5B/6B-compatible  
encoder/decoder  
AMD TAXIchip-compatible serial link  
Encoder  
AMD TAXIchip parallel COMMAND and DATA I/O bus  
Data from the host interface or Transmit FIFO is next passed  
to an Encoder block. The CY7C9689A contains both 4B/5B  
and 5B/6B encoders that are used to improve the serial  
transport characteristics of the data. For those systems that  
contain their own encoder or scrambler, this Encoder may be  
bypassed.  
architecture  
8-bit or 10-bit character size  
User-definable data packet or frame structure  
Two-octave data rate range  
Asynchronous (FIFOed) or synchronous data interface  
Embedded or bypassable FIFO data storage  
Encoded or non-encoded  
Serializer/Line Driver  
The data from the Encoder is passed to a Serializer. This  
Serializer operates at 10 or 12 times the character rate. With  
the internal FIFOs enabled, REFCLK can run at 1x, 2x, or 4x  
the character rate. With the FIFOs bypassed, REFCLK can  
operate at 1x or 2x the character rate. The serialized data is  
output in NRZI format from two PECL-compatible differential  
line drivers configured to drive transmission lines or optical  
modules.  
Multi-PHY capability  
This flexibility allows the CY7C9689A to meet the data  
transport needs of almost any system.  
Transmit Data Path  
Transmit Data Interface/Transmit Data FIFO  
The transmit data interface to the host system is configurable  
as either an asynchronous buffered (FIFOed) parallel interface  
or as a synchronous pipeline register. The bus itself can be  
configured for operation with either 8-bit or 10-bit character  
widths.  
Receive Data Interface  
Line Receiver/Deserializer/Framer  
Serial data is received at one of two PECL-compatible differ-  
ential line receivers. The data is passed to both a Clock and  
Data Recovery PLL and to a Deserializer that converts NRZI  
serial data into NRZ parallel characters. The Framer adjusts  
the boundaries of these characters to match those of the  
original transmitted characters.  
When configured for asynchronous operation (where the  
host-bus interface clock operates asynchronous to the serial  
character and bit stream clocks), the host interface becomes  
that of a synchronous FIFO clocked by TXCLK. In this config-  
uration an internal 256-character Transmit FIFO is enabled  
that allows the host interface to be written at any rate from DC  
to 50 MHz.  
Decoder  
The parallel characters are passed through a pair of 5B/4B or  
6B/5B decoders and returned to their original form. For  
Document #: 38-02020 Rev. *C  
Page 12 of 46  
CY7C9689A  
systems that make use of external decoding or descrambling,  
the decoder may be bypassed.  
made compatible with asynchronous or synchronous host  
system buses. These buses can take the form of external  
FIFOs, state machines, or other control structures. Data and  
command present on the TXDATA[9:0] and TXSC/D inputs are  
captured at the rising edge of the selected sample clock. The  
transmit data bus bit-assignments vary depending on the data  
encoding and bus-width selected. These bus bit-assignments  
are shown in Table 1, and list the functional names of these  
different signals. Note that the function of several of these  
signals changes in different operating modes. The logical  
sense of the enable and FIFO flag signals depends on the  
intended interface convention and is set by the EXTFIFO pin.  
Receive Data Interface/Receive Data FIFO  
Data from the decoder is passed either to a synchronous  
Receive FIFO or is passed directly to the output register. The  
output register can be configured for either 8-bit character or  
10-bit character operation.  
When configured for an asynchronous buffered (FIFOed)  
interface, the data is passed through a 256-character Receive  
FIFO that allows data to be read at any rate from DC to 50  
MHz. When configured for synchronous operation (Receive  
FIFO is bypassed) data is clocked out of the Receive Output  
register at up to 20 MHz when configured for 8-bit characters,  
or 16.67 MHz when configured for 10-bit characters. The  
receive interface is also configurable for FIFO flags with either  
HIGH or LOW status indication  
The transmit interface supports both synchronous and  
asynchronous clocking modes, each supporting both UTOPIA  
and Cascade timing models. The selection of the specific  
clocking mode is determined by the RANGESEL and SPDSEL  
inputs and the FIFO Bypass (FIFOBYP) signal.  
TXDATA[7:0]  
REFCLK  
TXCMD[3:0]  
Oscillator Speed Selection  
TXEN  
TXCLK  
TXSC/D  
CE  
The CY7C9689A is designed to operate over a two-octave  
range of serial signaling rates, covering the 50- to 200-MBaud  
range. To cover this wide range, the PLLs are configured into  
various sub-regions using the SPDSEL and RANGESEL  
inputs, and to a limited extent the BYTE8/10 input. These  
inputs are used to configure the various prescalers and clock  
dividers used with the transmit and receive PLLs.  
12  
Transmit Input Register  
14  
CY7C9689A TAXI HOTLink Transceiver  
Block Diagram Description  
Transmit Input/Output Register  
Transmit FIFO  
The CY7C9689A provides a synchronous interface for data  
and command inputs, instead of the TAXIs asynchronous  
strobed interface. The Transmit Input Register, shown in  
Figure 2, captures the data and command to be processed by  
the HOTLink Transmitter, and allows the input timing to be  
Table 1. Transmit Input Bus Signal Map  
To Encoder  
Block  
Figure 2. Transmit Input Register  
Transmit Encoder Mode[1]  
Encoded 8-bit  
Pre-encoded 10-bit  
Character Stream  
Encoded 10-bit  
Pre-encoded 12-bit  
Character Stream  
TXDATA Bus Input Bit  
TXSC/D  
Character Stream[2]  
Character Stream[3]  
TXSC/D  
TXSC/D  
TXDATA[0]  
TXDATA[0]  
TXDATA[1]  
TXDATA[2]  
TXDATA[3]  
TXDATA[4]  
TXDATA[5]  
TXDATA[6]  
TXDATA[7]  
TXCMD[3]  
TXCMD[2]  
TXCMD[1]  
TXCMD[0]  
TXD[0][4]  
TXD[1]  
TXD[2]  
TXD[3]  
TXD[4]  
TXD[5]  
TXD[6]  
TXD[7]  
TXD[8]  
TXD[9]  
TXDATA[0]  
TXDATA[1]  
TXDATA[2]  
TXDATA[3]  
TXDATA[4]  
TXDATA[5]  
TXDATA[6]  
TXDATA[7]  
TXDATA[8]  
TXDATA[9][3]  
TXCMD[1]  
TXD[0][5]  
TXD[1]  
TXD[2]  
TXD[3]  
TXD[4]  
TXD[5]  
TXD[6]  
TXD[7]  
TXD[8]  
TXD[9]  
TXD[10][5]  
TXD[11]  
TXDATA[1]  
TXDATA[2]  
TXDATA[3]  
TXDATA[4]  
TXDATA[5]  
TXDATA[6]  
TXDATA[7]  
TXDATA[8]/TXCMD[3]  
TXDATA[9]/TXCMD[2]  
TXCMD[1]  
TXCMD[0]  
TXCMD[0]  
Notes:  
1. All open cells are ignored.  
2. When ENCBYP is HIGH and BYTE8/10 is HIGH, transmitted bit order is the encoded form (MSB to LSB) of TXDATA[7,6,5,4] and TXDATA[3,2,1,0] or  
TXCMD[3,2,1,0] as selected by TXSC/D.  
3. When ENCBYP is HIGH and BYTE8/10 is LOW, transmitted bit order is the encoded form (MSB to LSB) of TXDATA[8,7,6,5,4] and TXDATA[9,3,2,1,0] or  
TXCMD[1,0] as selected by TXSC/D.  
4. When ENCBYP is LOW and BYTE8/10 is HIGH, the transmitted bit order is (LSB to MSB) TXD[0,1,2,3,4,5,6,7,8,9].  
5. When ENCBYP is LOW and BYTE8/10 is LOW, the transmitted bit order is (LSB to MSB) TXD[0,1,2,3,4,5,6,7,8,9,11,10].  
Document #: 38-02020 Rev. *C  
Page 13 of 46  
CY7C9689A  
Synchronous Interface  
write is enabled (the device is selected and TXEN is sampled  
asserted), data is captured in the transmit input register and  
stored into the Transmit FIFO. All Transmit FIFO write opera-  
tions are clocked by TXCLK.  
Synchronous interface clocking operates the entire transmit  
data path synchronous to REFCLK. It is enabled by  
connecting FIFOBYP LOW to disable the internal FIFOs.  
The Transmit FIFO presents Full, Half-Full, and Empty FIFO  
flags. These flags are provided synchronous to TXCLK. When  
the Transmit FIFO is enabled, it allows operation with a  
Moore-type external controlling state machine. When  
configured for Cascade timing, the timing and active levels of  
these signals are also designed to support direct expansion to  
Cypress CY7C42x5 synchronous FIFOs.  
Asynchronous Interface  
Asynchronous interface clocking controls the writing of host  
bus data into the Transmit FIFO. It is enabled by setting  
FIFOBYP HIGH to enable the internal FIFOs. In these config-  
urations, all writes to the Transmit Input Register, and  
associated transfers to the Transmit FIFO, are controlled by  
TXCLK. The remainder of the transmit data path is clocked by  
REFCLK or synthesized derivatives of REFCLK.  
Regardless of bus width (8- or 10-bit characters) the Transmit  
FIFO can be clocked at any rate from DC to 50 MHz. This  
gives the Transmit FIFO a maximum bandwidth of 50 million  
characters per second. Since the serial outputs can only move  
20 million characters per second at their fastest operating rate,  
there is ample time to service multiple CY7C9689A HOTLinks  
with a single controller.  
Shared Bus Timing Model  
The Shared Bus Timing Model allows multiple CY7C9689A  
transmitters to be accessed from a common host bus. It is  
enabled by setting EXTFIFO LOW. In shared bus timing, the  
TXEMPTY and TXFULL outputs and TXEN input are all active  
LOW signals. If the CY7C9689A is addressed by asserting CE  
LOW, it becomes selectedwhen TXEN is asserted LOW.  
Following selection, data or command is written into the  
Transmit FIFO on every clock cycle where TXEN remains  
LOW.  
The read port of the Transmit FIFO is connected to a logic  
block that performs data formatting and validation. All data  
read operations from the Transmit FIFO are controlled by a  
Transmit Control State Machine that operates synchronous to  
REFCLK.  
Encoder Block  
Cascade Timing Model  
The Encoder logic block performs two primary functions:  
encoding the data for serial transmission and generating BIST  
patterns to allow at-speed link and device testing.  
The Cascade timing model is a variation of the shared bus  
timing model. Here the TXEMPTY and TXFULL outputs, and  
TXEN input, are all active HIGH signals. Cascade timing  
makes use of the same selection sequences as shared bus  
timing, but write data accesses use a delayed write. This  
delayed write is necessary to allow direct coupling to external  
FIFOs, or to state machines that initiate a write operation one  
clock cycle before the data is available on the bus.  
BIST LFSR  
The Encoder logic block operates on data stored in a register.  
This register accepts information directly from the Transmit  
FIFO, the Transmit Input Register or from the Transmit Control  
State Machine when it inserts special characters into the data  
stream.  
Cascade timing is enabled by setting EXTFIFO HIGH.  
When used for FIFO depth expansion, Cascade timing allows  
the size of the internal Transmit FIFO to be expanded to an  
almost unlimited depth. It allows a CY7C42x5 series  
synchronous FIFO to be attached to the transmit interface  
without any extra logic, as shown in Figure 3.  
This same register is converted into a Linear Feedback Shift  
Register (LFSR) when the BIST pattern generator is enabled  
(TXBISTEN is LOW). When enabled, this LFSR generates a  
511-character sequence that includes all Data and Special  
Character codes, including the explicit violation symbols. This  
provides a predictable but pseudo-random sequence that can  
be matched to an identical LFSR in the Receiver.  
CY7C42x5 FIFO  
FF* EF*  
WEN* REN*  
CY7C9689A  
FF*  
TXEN  
Encoder  
WEN*  
TXFULL  
The data passed through the Transmit FIFO and pipeline  
register, or as received directly from the Transmit Input  
Register, is seldom in a form suitable for transmission across  
a serial link. The characters must usually be processed or  
transformed to guarantee:  
D
D
Q
TXDATA  
TXSC/D  
TXCLK  
WCLK RCLK  
TXCLK  
a minimum transition density (to allow the serial receiver PLL  
to extract a clock from the data stream)  
some way to allow the remote receiver to determine the  
correct character boundaries (framing).  
1”  
EXTFIFO  
The CY7C9689A contains an integrated 4B/5B encoder that  
accepts 8-bit data characters and converts these into 10-bit  
transmission characters that have been optimized for  
transport on serial communications links. This 4B/5B encoding  
scheme is compliant with the ANSI X3T9.5 (FDDI)  
committees 4B/5B code. The CY7C9689A also contains a  
5B/6B encoder that accepts 10-bit data characters and  
converts these into 12-bit transmission characters.  
Figure 3. External FIFO Depth Expansion of the  
CY7C9689A Transmit Data Path  
Transmit FIFO  
The Transmit FIFO is used to buffer data and command  
captured in the input register for later processing and trans-  
mission. This FIFO is sized to hold 256 14-bit characters.  
When the Transmit FIFO is enabled, and a Transmit FIFO  
Document #: 38-02020 Rev. *C  
Page 14 of 46  
CY7C9689A  
The 4B/5B, 5B/6B encoder can be bypassed for those  
systems that operate with external 4B/5B or 5B/6B encoders  
or use alternate forms of encoding or scrambling to ensure  
good transmission characteristics. The complete encoding  
tables are listed in Table 7 and Table 8.  
OUTA± receives its data directly from the transmit shifter, while  
OUTB± receives its data from the Routing Matrix. These two  
outputs (OUTA± and OUTB±) are capable of direct connection  
to +5V optical modules, and can also directly drive DC- or  
AC-coupled transmission lines.  
When the Encoder is enabled, the transmit data characters (as  
passed through the Transmit FIFO and pipeline register) are  
converted to either a 10-bit or 12-bit Data symbol or a 10-bit or 12-bit  
Command Character, depending upon the state of the TXSC/D  
input. If TXSC/D is HIGH, the data on the command inputs are  
encoded into Command Character as shown in Table 8. If TXSC/D  
is LOW, the data inputs are encoded using the Data Character  
encoding in Table 7.  
The PECL-compatible Output Drivers can be viewed as  
programmable current sources. The output voltage is deter-  
mined by the output current and the load impedance ZLOAD  
.
The desired output voltage swing is therefore controlled by the  
current-set resistor RCURSET associated with that driver.  
Different RCURSET values are required for different line  
impedance/amplitude combinations. The output swing is  
designed to center around VDD1.33V. Each output must be  
externally biased to VDD1.33V.  
The 4B/5B, 5B/6B coding function of the Encoder can be  
bypassed for systems that include an external coder or  
scrambler function as part of the controller or host system. This  
is performed by setting ENCBYP LOW. With the encoder  
bypassed, each 10-bit or 12-bit character (as captured in the  
Transmit Input Register) is passed directly to the Transmit  
Shifter (or Transmit FIFO) without modification.  
This differential output-swing can be specified two ways: either  
as a peak-to-peak voltage into a single-end load, or as an  
absolute differential voltage into a differential load.  
When specified into a single-ended load (one of the outputs  
switching into a load), the single output will both source and  
sink current as it changes between its HIGH and LOW levels.  
The voltage difference between this HIGH level and LOW level  
determine the peak-to-peak signal-swing of the output. This  
amplitude relationship is controlled by the load impedance on  
the driver, and by the resistance of the RCURSET resistor for  
that driver, as listed in Eq. 1  
Transmit Shifter  
The Transmit Shifter accepts 10-bit (BYTE8/10 = HIGH) or  
12-bit (BYTE8/10 = LOW) parallel data from the Encoder block  
once each character time, and shifts it out the serial interface  
output buffers using a PLL-multiplied bit-clock with NRZI  
encoding. This bit-clock runs at 2.5, 5, or 10 times the REFCLK  
rate (3, 6, or 12 times when BYTE8/10 is LOW) as selected by  
RANGESEL and SPDSEL (see Table 3). Timing for the  
parallel transfer is controlled by the counter and dividers in the  
Clock Multiplier PLL and is not affected by signal levels or  
timing at the input pins. Bits in each character are shifted out  
LSB first.  
180 × ZLOAD  
RCURSET = ---------------------------------  
Eq. 1  
VOPP  
In Eq. 1, VOPP is the difference in voltage levels at one output  
of the differential driver when that output is driving HIGH and  
LOW, ZLOAD is that load seen by the one output when it is  
sourcing and sinking current. With a known load impedance  
and a desired signal swing, it is possible to calculate the value  
of the associated CURSETA or CURSETB resistor that sets  
this current.  
Routing Matrix  
The Routing Matrix is a precision multiplexor that allows local  
diagnostic loopback. The signal routing for the transmit serial  
outputs is controlled by the DLB input as listed in Table 2.  
Unused differential output drivers should be left open, and can  
reduce their power dissipation by connecting their respective  
Table 2. Transmit Data Routing Matrix  
CURSETx input to VDD  
.
DLB[0]  
Data Connections  
Transmit PLL Clock Multiplier  
The Transmit PLL Clock Multiplier accepts an external clock at  
the REFCLK input, and multiples that clock by 2.5, 5, or 10 (3,  
6, or 12 when BYTE8/10 is LOW and the encoder is disabled)  
to generate a bit-rate clock for use by the transmit shifter. It  
also provides a character-rate clock used by the Transmit  
Controller state machine.  
0
TRANSMIT  
OUTA  
OUTB  
SHIFTER  
A/B  
INB  
INA  
RECEIVE  
PLL  
The clock multiplier PLL can accept a REFCLK input between  
8 MHz and 40 MHz, however, this clock range is limited by the  
operation mode of the CY7C9689A as selected by the  
SPDSEL and RANGESEL inputs, and to a limited extent, by  
the BYTE8/10 and FIFOBYP signals. The operating serial  
signalling rate and allowable range of REFCLK frequencies is  
listed in Table 3.  
1
TRANSMIT  
SHIFTER  
OUTA  
OUTB  
A/B  
INB  
INA  
RECEIVE  
PLL  
Transmit Control State Machine  
The Transmit Control State Machine responds to multiple  
inputs to control the data stream passed to the encoder. It  
operates in response to:  
Serial Line Drivers  
The serial interface PECL Output Drivers (ECL referenced to  
+5V) are the transmission line drivers for the serial media.  
Document #: 38-02020 Rev. *C  
Page 15 of 46  
CY7C9689A  
Table 3. Speed Select and Range Select Settings  
generally used only for local diagnostic loopback purposes. The  
serial line receiver inputs are all differential, and will accommodate  
wire interconnect with filtering losses or transmission line attenu-  
ation greater than 9 dB (VDIF > 200 mV, or 400 mV peak-to-peak  
differential) or can be directly connected to +5V fiber-optic interface  
modules (any ECL logic family, not limited to ECL 100K). The  
common-mode tolerance of these line receivers accommodates a  
wide range of signal termination voltages.  
Serial  
Data Rate  
(MBaud)  
REFCLK[7]  
Frequency  
(MHz)  
SPDSEL  
LOW  
RANGESEL  
LOW  
50100  
50100  
1020  
2040  
1020  
2040  
LOW  
HIGH[6]  
As can be seen in Table 2, these inputs are configured to allow  
single-pin control for most applications. For those systems  
requiring selection of only INA± or INB±, the DLB signals can be  
tied LOW, and the A/B selection can be performed using only  
A/B. For those systems requiring only a single input and a local  
loopback, the A/B can be tied HIGH or LOW, and DLB can be  
used for loopback control.  
HIGH  
HIGH  
LOW  
100200  
100200  
HIGH  
the state of the FIFOBYP input  
the presence of data in the Transmit FIFO  
the contents of the Transmit FIFO  
Signal Detect  
the state of the transmitter BIST enable (TXBISTEN)  
the state of external halt signal (TXHALT).  
The selected Line Receiver (that routed to the clock and data  
recovery PLL) is simultaneously monitored for:  
These signals are used by the Transmit Control State Machine  
to control the data formatter, read access to the Transmit FIFO  
and BIST. They determine the content of the characters  
passed to the Encoder and Transmit Shifter.  
analog amplitude (> 400 mV pk-pk)  
transition density  
received data stream outside normal frequency range  
(±400 ppm)  
When the Transmit FIFO is bypassed, the Transmit Control  
State Machine operates synchronous to REFCLK. In this  
mode, data from the TXDATA bus is passed directly from the  
Input Register to the Pipeline Register. If no data is enabled  
into the Input register (TXEN is deasserted or TXFULL is  
asserted) then the Transmit Control State Machine presents a  
JK or LM (when BYTE8/10 = LOW) Command Character code  
to the Encoder to maintain link synchronization.  
carrierdetected.  
All of these conditions must be valid for the Signal Detect block  
to indicate a valid signal is present. This status is presented on  
the LFI (Link Fault Indicator) output, which changes  
synchronous to RXCLK. While link status is monitored inter-  
nally at all times, it is necessary to have transitions on RXCLK  
to allow this signal to change externally.  
If both the Encoder and Transmit FIFO are bypassed and no  
data is enabled into the Input Register, the Transmit Control  
State Machine injects JK or LM (when BYTE8/10 = LOW) into  
the Serial Shifter Register at this time slot. This also occurs if  
the Encoder is bypassed, the Transmit FIFO is enabled, and  
the Transmit FIFO is empty.  
Clock/Data Recovery  
The extraction of a bit-rate clock and recovery of data bits from  
the received serial stream is performed within the Clock/Data  
Recovery (CDR) block. The clock extraction function is  
performed by a high-performance embedded PLL that tracks  
the frequency of the incoming bit stream and aligns the phase  
of its internal bit-rate clock to the transitions in the serial data  
stream.  
External Control of Data Flow  
The Transmit Control State Machine supports halting of data  
transmission by the TXHALT input. This control signal input is  
only interpreted when the Transmit FIFO is enabled. TXHALT  
is brought directly to the state machine without going through  
the Transmit FIFO.  
The CDR makes use of the clock present at the REFCLK input.  
It is used to ensure that the VCO (within the CDR) is operating  
at the correct frequency (rather than some harmonic of the bit  
rate), to improve PLL acquisition time, and to limit unlocked  
frequency excursions of the CDR VCO when no data is  
present at the serial inputs.  
The assertion of TXHALT causes character processing to stop  
at the next FIFO character location. No additional data is read  
from the Transmit FIFO until TXHALT is deasserted.  
Regardless of the type of signal present, the CDR will attempt  
to recover a data stream from it. If the frequency of the  
recovered data stream is outside the limits for the range  
controls, the CDR PLL will track REFCLK instead of the data  
stream. When the frequency of the selected data stream  
returns to a valid frequency, the CDR PLL is allowed to track  
the received data stream. The frequency of REFCLK is  
required to be within ±400 ppm of the frequency of the clock  
that drives the REFCLK signal at the remote transmitter to  
ensure a lock to the incoming data stream.  
TXHALT may be used to prevent a remote FIFO overflow,  
which would result in lost data. This back-pressure mechanism  
can significantly improve data integrity in systems that cannot  
guarantee the full bandwidth of the host system at all times.  
Serial Line Receivers  
Two differential line receivers, INA± and INB±, are available for  
accepting serial data streams, with the active input selected  
using the A/B input. The DLB input allow the transmit Serializer  
output to be selected as a third input serial stream, but this path is  
Notes:  
6. When SPDSEL is LOW and the FIFOs are bypassed (FIFOBYP is LOW), the RANGESEL input is ignored and is internally mapped to the LOW setting.  
7. When configured for 12-bit preencoded data (BYTE8/10 and ENCBYP are both LOW) the allowable REFCLK ranges are 8.33 to 16.67 MHz and 16.67 to  
33.33 MHz.  
Document #: 38-02020 Rev. *C  
Page 16 of 46  
CY7C9689A  
For systems using multiple or redundant connections, the LFI  
output can be used to select an alternate data stream. When  
an LFI indication is detected, external logic can toggle  
selection of the INA± and INB± inputs through the A/B input.  
When a port switch takes place, it is necessary for the PLL to  
reacquire the new serial stream and frame to the incoming  
characters.  
BIST LFSR  
The output register of the Decoder block is normally used to  
accumulate received characters for delivery to the Receive  
Formatter block. When configured for BIST mode (RXBISTEN  
is LOW), this register becomes a signature pattern generator  
and checker by logically converting to a Linear Feedback Shift  
Register (LFSR). When enabled, this LFSR generates a  
511-character sequence that includes all Data and Command  
Character codes, including the explicit violation symbols. This  
provides a predictable but pseudo-random sequence that can  
be matched to an identical LFSR in the Transmitter. When  
synchronized with the received data stream, it checks each  
character in the Decoder with each character generated by the  
LFSR and indicates compare errors at the VLTN output of the  
Receive Output Register.  
Clock Divider  
This block contains the clock division logic, used to transfer the  
data from the Deserializer/Framer to the Decoder once every  
character (once every ten or twelve bits) clock. This counter is  
free running and generates outputs at the bit-rate divided by  
10 (12 when the BYTE8/10 is LOW). When the Receive FIFO  
is bypassed, one of these generated clocks is driven out the  
RXCLK pin.  
The LFSR is initialized by the BIST hardware to the BIST loop  
start code of HEX data 00 (00 is sent only once per BIST loop).  
Once the start of the BIST loop has been detected by the  
receiver, RXRVS is asserted for pattern mismatches between  
the received characters and the internally generated character  
sequence. Code rule violations or running disparity errors that  
occur as part of the BIST loop do not cause an error indication.  
RXFULL pulses asserted for one RXCLK cycle per BIST loop and  
can be used to check test pattern progress.  
Deserializer/Framer  
The CDR circuit extracts bits from the serial data stream and  
clocks these bits into the Shifter/Framer at the bit-clock rate.  
When enabled, the Framer examines the data stream looking  
for JK or LM (when BYTE8/10 is LOW) characters at all  
possible bit positions. The location of this character in the data  
stream is used to determine the character boundaries of all  
following characters.  
The specific patterns checked by the receiver are described in  
Table 4.  
The framer operates in two different modes, as selected by the  
RFEN input. When RFEN is asserted (HIGH), the framer is  
allowed to reset the internal character boundaries on any  
detected JK or LM (when BYTE8/10 is LOW) character.  
If a large number of errors are detected, the receive BIST state  
machine aborts the compare operations and resets the LFSR  
to the D0.0 state to look for the start of the BIST sequence  
again.  
If RFEN is LOW, the framer is disabled and no changes are  
made to character boundaries.  
Receive Control State Machine  
The framer in the CY7C9689A operates by shifting the internal  
character position to align with the character clock. This  
ensures that the recovered clock does not contain any signif-  
icant phase changes/hops during normal operation or framing,  
and allows the recovered clock to be replicated and distributed  
to other circuits using PLL-based logic elements.  
The Receive Control State Machine responds to multiple input  
conditions to control the routing and handling of received  
characters. It controls the staging of characters across various  
registers and the Receive FIFO. It controls the various discard  
policies and error control within the receiver, and operates in  
response to:  
Decoder Block  
the received character stream  
The decoder logic block performs two primary functions:  
decoding the received transmission characters back into Data  
and Command Character codes, and comparing generated  
BIST patterns with received characters to permit at-speed link  
and device testing.  
the room for additional data in the Receive FIFO  
the state of the receiver BIST enable (RXBISTEN)  
the state of FIFOBYP.  
These signals and conditions are used by the Receive Control  
State Machine to control the Receive Formatter, write access  
to the Receive FIFO, the Receive Output register, and BIST.  
They determine the content of the characters passed to each  
of these destinations.  
5B/4B, 6B/5B Decoder  
The framed parallel output of the Deserializer is passed to the  
5B/4B, 6B/5B Decoder. If the Decoder is enabled, it is trans-  
formed from a 10-bit or 12-bit transmission character back to  
the original Data and Command Character codes. This block  
uses the standard decoder patterns in Table 7 and Table 8 of  
this data sheet. Data Patterns on the data bus are indicated by  
a LOW on RXSC/D, and Command Character codes on the  
command bus are indicated by a HIGH. Invalid patterns or disparity  
errors are signaled as errors by a HIGH on VLTN.  
The Receive Control State Machine always operates  
synchronous to the recovered character clock (bit-clock/10 or  
bit-clock/12). When the Receive FIFO is bypassed, RXCLK  
becomes an output that changes synchronous to the internal  
character clock. RXCLK operates at the same frequency as  
the internal character clock.  
Discard Policies  
If the Decoder is bypassed and BYTE8/10 is HIGH, the ten  
(10) data bits of each transmission character are passed  
unchanged from the framer to the Pipeline Register.  
When the Receive FIFO is enabled, the Receive Control State  
Machine has the ability to selectively discard specific  
characters from the data stream that are determined by the  
present configuration as being unnecessary. When discarding  
is enabled, it reduces the host system overhead necessary to  
keep the Receive FIFO from overflowing and losing data.  
When the Decoder is bypassed and BYTE8/10 is LOW, the  
twelve (12) data bits of each transmission character are  
passed unchanged from the framer to the Pipeline Register.  
Document #: 38-02020 Rev. *C  
Page 17 of 46  
CY7C9689A  
able 4. CY7C9689A TAXI HOTLink BIST Sequence  
D.00 C.JK C.IH C.SR C.SS C.QQ D.FB D.77  
C.JK C.IH C.QI D.EE C.RR D.B3 D.55 D.2C  
C.TR C.SR C.SS C.QQ D.F8 C.TS C.QH D.D2  
D.89 D.42 C.HI D.94 C.TT C.TR C.QI D.EB  
D.3D D.1E C.HH D.8F D.4B D.23 D.11 D.04  
C.JK C.RS D.C5 D.68 C.II  
C.RS D.C0 C.TS  
C.RR D.BC C.TT C.QH D.D7 D.6D D.3A C.HH  
D.73 D.35 D.1C C.JK C.RS D.CF D.6B D.33  
D.15 D.0C C.JK C.RS D.CD D.6A C.HI D.91  
D.A8 C.TT C.QH D.D4 C.TS C.TR C.QI D.E3  
D.99 D.46 C.HI D.96 C.HQ D.AE C.HQ D.A3  
D.44 C.II  
C.IH C.QI D.E6 C.RR D.B2 C.HQ  
D.71 D.34 C.JK C.IH C.QI D.ED D.7A C.HI  
D.51 D.24 C.JK C.IH C.QI D.EC C.TS C.QH  
C.QI D.E0 C.TS C.TR C.SR C.SS C.SS C.SS  
D.D1 D.64 C.II  
C.IH C.QI D.E4 C.RR C.TR  
C.SS C.QQ D.F0 C.TS C.TR C.SR C.QQ D.F4  
C.QQ D.FC C.TS C.QH D.D3 D.65 D.38 C.JK  
C.TS C.TR C.QI D.E1 D.70 C.II  
C.IH C.SR  
C.RS D.C6 C.RR D.B6 C.HQ D.AA C.HQ D.A1  
D.9B D.47 D.29 D.12 C.HH D.8C C.TT C.QH  
D.C4 C.TS C.TR C.QI D.E2 C.RR D.B0 C.TT  
D.50 C.II  
C.IH C.SR C.QQ D.FD D.7E C.HI  
D.DD D.6E C.HI D.93 D.45 D.28 C.JK C.RS  
C.TR C.SR C.QQ D.F6 C.RR D.BA C.HQ D.A9  
D.52 C.HI D.9C C.TT C.QH D.DF D.6F D.3B  
D.C8 C.TS C.QH D.D8 C.TS C.QH D.DA C.RR  
D.08 C.JK C.RS D.CC C.TS C.QH D.D9 D.66  
D.17 D.0D D.0A C.HH D.85 D.48 C.II  
C.RS  
D.BD D.5E C.HI D.9F D.4F D.2B D.13 D.05  
C.HI D.92 C.HQ D.AC C.TT C.QH D.D5 D.6C  
C.II  
C.RS D.C1 D.60 C.II  
C.IH C.SR C.SS  
C.SS C.SS C.QQ D.F1 D.74 C.II  
C.IH C.QI  
D.E5 D.78 C.II  
C.RS D.C2 C.RR D.B4 C.TT  
C.TR C.QI D.E9 D.72 C.HI D.98 C.TT C.QH  
D.02 C.HH D.84 C.TT C.TR C.QI D.EA C.RR  
D.DE C.RR D.BF D.5F D.2F D.1B D.07 D.09  
D.B1 D.54 C.II C.IH C.QI D.E7 D.79 D.36  
C.RR D.B5 D.5C C.II C.RS D.CB D.63 D.31  
C.HH D.8A C.HQ D.A5 D.58 C.II  
C.RS D.CA  
D.14 C.JK C.IH C.QI D.EF D.7B D.37 D.1D  
C.TR C.SR C.SS C.QQ D.F9 D.76 C.HI D.9A  
D.0E C.HH D.87 D.49 D.22 C.HH D.80 C.TT  
C.HQ D.AD D.5A C.HI D.9D D.4E C.HI D.97  
C.SS C.QQ D.FA C.RR D.B9 D.56 C.HI D.9E  
C.HQ D.A6 C.HQ D.A2 C.HQ D.AO C.TT C.TR  
D.4D D.2A C.HH D.81 D.40 C.II  
C.IH C.SR  
C.HQ D.AF D.5B D.27 D.19 D.06 C.HH D.86  
C.SR C.SS C.SS C.QQ D.F2 C.RR D.B8 C.TT  
D.18 C.JK C.RS D.CE C.RR D.B7 D.5D D.2E  
C.SS C.QQ D.F3 D.75 D.3C C.JK C.RS D.C7  
C.QH D.DB D.67 D.39 D.16 C.HH D.8E C.HQ  
C.QH D.D6 C.RR D.BE C.HQ D.AB D.53 D.25  
C.HH D.83 D.41 D.20 C.JK C.IH C.SR C.SS  
D.69 D.32 C.HH D.88 C.TT C.QH D.DC C.TS  
D.A7 D.59 D.26 C.HH D.82 C.HQ D.A4 C.TT  
C.TR C.QI D.E8 C.TS C.QH D.D0 C.TS C.TR  
D.30 C.JK C.IH C.SR C.QQ D.FE C.RR D.BB  
C.SR C.QQ D.F5 D.7C C.II  
C.RS D.C3 D.61  
D.57 D.2D D.1A C.HH D.8D D.4A C.HI D.95  
C.TR C.SR C.QQ D.F7 D.7D D.3E C.HH D.8B  
D.4C C.II  
C.RS D.C9 D.62 C.HI D.90 C.TT  
D.43 D.21 D.10 C.JK C.IH C.SR C.QQ D.FF  
D.7F D.3F D.1F D.0F D.0B D.03 D.01 GOTO  
Start  
The discard policy is configured as part of the operating mode  
and is set using the RXMODE[1:0] inputs. The four discard  
policies are listed in Table 5.  
Table 5. Receiver Discard Policies  
Policy # Policy Description  
Policy 0 is the simplest and also applies for all conditions  
where the Receive FIFO is bypassed. In this mode, every  
character that is received is placed into the Receive FIFO  
(when enabled) or into the Receive Output Register.  
0 (00)  
1 (01)  
Keep all received characters  
Process Commands, discard all but the last JK or  
LM SYNC character  
2 (1X) Process Commands, discard all C5.0 characters  
Document #: 38-02020 Rev. *C  
Page 18 of 46  
CY7C9689A  
In discard policy 1, the JK or LM SYNC character, which is  
automatically transmitted when no data is present in the  
Transmit FIFO, is treated differently here. In this mode,  
whenever two or more adjacent JK or LM characters are  
received, all of them are discarded except the last one  
received before any other character type. This allows these fill  
characters to be removed from the data stream, but the last  
SYNC character which can be used as a delimiter.  
CY7C42x5 FIFO  
EF* FF*  
REN* WEN*  
CY7C9689A  
EF*  
RXEN  
REN*  
RXEMPTY  
Q
Q
D
RXDATA  
RXSC/D  
Policy 2 is identical to policy 1 except that all C5.0 characters  
are removed from the data stream.  
RXCLK  
When the FIFOs are bypassed (FIFOBYP LOW), no  
characters are actually discarded, but the receiver discard  
policy can be used to control external filtering of the data. The  
RXEMPTY FIFO flag is used to indicate if the character on the  
output bus is valid or not. In discard policy 0, the RXEMPTY  
flag is always deasserted to indicate that valid data is always  
present. In discard policy 1, the RXEMPTY flag indicates an  
empty condition for all but the last JK or LM character before  
any other character is presented. In discard policy 2, the  
RXEMPTY flag indicates an empty condition for all JK or LM  
SYNC characters. When any other character is present, this  
flag indicates that valid or interestingData or Special  
Characters are present.  
RCLK WCLK  
RXCLK  
1”  
EXTFIFO  
Figure 4. External FIFO Depth Expansion of the  
CY7C9689A Receive Data Path  
Receive Input Register  
The input register is clocked by the rising edge of RXCLK. It  
samples numerous signals that control the reading of the  
Receive FIFO and operation of the Receive Control State  
Machine.  
Receive FIFO  
The Receive FIFO is used to buffer data captured from the  
selected serial stream for later processing by the host system.  
This FIFO is sized to hold 256 14-bit characters. When the  
FIFO is enabled, it is written to by the Receive Control State  
Machine. When data is present in the Receive FIFO (as  
indicated by the RXFULL, RXHALF, and RXEMPTY Receive  
FIFO status flags), it can be read from the Output Register by  
asserting CE and RXEN.  
Receive Output Register  
The Receive Output Register changes in response to the  
rising edge of RXCLK. The Receive FIFO status flag outputs  
of this register are placed in a High-Z state when the  
CY7C9689A is not addressed (CE is sampled HIGH). The  
RXDATA bus output drivers are enabled when the device is  
selected by RXEN being asserted in the RXCLK cycle immedi-  
ately following that in which the device was addressed (CE is  
sampled LOW), and RXEN being sampled by RXCLK. This  
initiates a Receive FIFO read cycle.  
The read port on the Receive FIFO may be configured for the  
same two timing models as the transmit interface: UTOPIA  
and Cascade. Both are forms of a FIFO interface. The UTOPIA  
timing model has active LOW RXEMPTY and RXFULL status  
flags, and an active LOW RXEN enable. When configured for  
Cascade operation, these same signals are all active HIGH.  
Either timing model supports connection to various host bus  
interfaces, state machines, or external FIFOs for depth  
expansion (see Figure 4).  
Just as with the TXDATA bus on the Transmit Input Register,  
the receive outputs are also mapped by the specific decoding  
and bus-width selected by the ENCBYP, BYTE8/10 and  
FIFOBYP inputs. These assignments are shown in Table 6.  
If the Receive FIFO and Decoder are bypassed, all received  
characters are passed directly to the Receive Output Register.  
If framing is enabled, and JK or LM sync characters have been  
detected meeting the present framing requirements, the  
output characters will appear on proper character boundaries.  
If framing is disabled (RFEN is LOW) or sync characters have  
not been detected in the data stream, the received characters  
may not be output on their proper 10-bit boundaries. In this  
mode, some form of external framing and decoding/descram-  
bling must be used to recover the original source data.  
The Receive FIFO presents Full, Half-Full, and Empty FIFO  
status flags. These flags are provided synchronous to RXCLK  
to allow operation with a Moore-type external controlling state  
machine. When configured with the Receive FIFO enabled,  
RXCLK is an input. When the Receive FIFO is bypassed  
(FIFOBYP is LOW), RXCLK is an output operating at the  
received character rate.  
Document #: 38-02020 Rev. *C  
Page 19 of 46  
CY7C9689A  
Table 6. Receiver Output Bus Signal Map  
Receiver Decoder Mode[1]  
Encoded 8-bit  
Pre-encoded 10-bit  
Character Stream  
Encoded 10-bit  
Pre-encoded 12-bit  
Character Stream  
RXDATA Bus Output Bit Character Stream[8]  
Character Stream[9]  
RXSC/D  
RXDATA[0]  
RXSC/D  
RXDATA[0]  
RXDATA[1]  
RXDATA[2]  
RXDATA[3]  
RXDATA[4]  
RXDATA[5]  
RXDATA[6]  
RXDATA[7]  
RXCMD[3]  
RXCMD[2]  
RXCMD[1]  
RXCMD[0]  
VLTN  
RXSC/D  
RXDATA[0]  
RXDATA[1]  
RXDATA[2]  
RXDATA[3]  
RXDATA[4]  
RXDATA[5]  
RXDATA[6]  
RXDATA[7]  
RXDATA[8]  
RXDATA[9][9]  
RXCMD[1]  
RXCMD[0]  
VLTN  
RXD[0][10, 11]  
RXD[1]  
RXD[2]  
RXD[3]  
RXD[4]  
RXD[5]  
RXD[6]  
RXD[7]  
RXD[8]  
RXD[9]  
RXD[0][10, 12]  
RXD[1]  
RXDATA[1]  
RXDATA[2]  
RXD[2]  
RXDATA[3]  
RXD[3]  
RXDATA[4]  
RXD[4]  
RXDATA[5]  
RXD[5]  
RXDATA[6]  
RXD[6]  
RXDATA[7]  
RXD[7]  
RXDATA[8]/RXCMD[3]  
RXDATA[9]/RXCMD[2]  
RXCMD[1]  
RXD[8]  
RXD[9]  
RXD[10][12]  
RXCMD[0]  
RXD[11]  
VLTN  
Notes:  
8. When BYTE8/10 is HIGH, received bit order is decoded form the serial stream and presented (MSB to LSB) at RXDATA[7,6,5,4] and RXDATA[3,2,1,0] or  
RXCMD[3,2,1,0] as indicated by RXSC/D.  
9. When BYTE8/10 is LOW, received bit order is decoded form the serial stream and presented (MSB to LSB) at RXDATA[8,7,6,5,4] and RXDATA[9,3,2,1,0]  
or RXCMD[1,0] as indicated by RXSC/D.  
10. First bit shifted into the receiver.  
11. When ENCBYP is LOW and BYTE8/10 is HIGH, the received bit order is (LSB to MSB) RXD[0,1,2,3,4,5,6,7,8,9].  
12. When ENCBYP is LOW and BYTE8/10 is LOW, the received bit order is (LSB to MSB) RXD[0,1,2,3,4,5,6,7,8,9,11,10].  
Document #: 38-02020 Rev. *C  
Page 20 of 46  
CY7C9689A  
DC Input Voltage ................................... 0.5V to VDD + 0.5V  
Maximum Ratings  
Static Discharge Voltage...........................................> 2001V  
(per MIL-STD-883, Method 3015)  
(Above which the useful life may be impaired. For user guide-  
lines, not tested.)  
Latch-up Current.....................................................> 200 mA  
Operating Range  
Storage Temperature .................................65°C to +150°C  
Ambient Temperature with (Power Applied)55°C to +125°C  
Supply Voltage to Ground Potential............... 0.5V to +6.5V  
DC Voltage Applied to Outputs ..............0.5V to VDD + 0.5V  
Output Current into TTL Outputs (LOW)......................30 mA  
Range  
Commercial  
Industrial  
Ambient Temperature  
0°C to +70°C  
VDD  
5.0V ± 10%  
5.0V ± 10%  
40°C to +85°C  
CY7C9689A DC Electrical Characteristics Over the Operating Range  
Parameter  
Description  
Test Conditions  
Min.  
Max.  
Unit  
TTL Outputs  
VOHT  
VOLT  
IOST  
Output HIGH Voltage  
Output LOW Voltage  
IOH = 2 mA, VDD = Min.  
IOL = 8 mA, VDD = Min.  
VOUT = 0V[13]  
2.4  
V
V
0.4  
80  
20  
Output Short Circuit Current  
30  
20  
mA  
mA  
IOZL  
High-Z Output Leakage Current  
TTL Inputs  
VIHT  
VILT  
Input HIGH Voltage  
2.0  
VCC  
0.8  
V
Input LOW Voltage  
0.5  
V
IIHT  
Input HIGH Current  
VIN = VDD  
VIN = 0.0V  
VIN = VCC  
VIN = 0.0V  
±40  
40  
+300  
µA  
µA  
µA  
µA  
IILT  
Input LOW Current  
IILPDT  
IILPUT  
Input HIGH Current with Internal Pull-down  
Input LOW Current with Internal Pull-up  
300  
Transmitter PECL-Compatible Output Pins: OUTA+, OUTA, OUTB+, OUTB−  
VOHE  
VOLE  
VODIF  
Output HIGH Voltage (VDD referenced)  
Load = 50to VDD 1.33V;  
RCURSET = 10k  
V
DD 1.03 VDD 0.83  
V
V
Output LOW Voltage (VDD referenced)  
Load = 50to VDD 1.33V;  
RCURSET = 10k  
V
DD 2.0  
V
DD 1.62  
Output Differential Voltage |(OUT+) (OUT)| Load = 50to VDD 1.33V;  
600  
1100  
mV  
RCURSET = 10k  
Receiver Single-ended PECL-Compatible Input Pin: CARDET  
VIHE  
VILE  
IIHE  
IILE  
Input HIGH Voltage (VDD referenced)  
Input LOW Voltage (VDD referenced)  
Input HIGH Current  
V
DD 1.165  
VDD  
DD 1.475  
V
V
2.5  
V
VIN = VIHE(min.)  
VIN = VILE(max.)  
+40  
µA  
µA  
Input LOW Current  
40  
200  
2.5  
Receiver Differential Line Receiver Input Pins: INA+, INA, INB+, INB−  
VDIFF  
VIHH  
VILL  
Input Differential Voltage |(IN+) (IN)|  
Highest Input HIGH Voltage  
Lowest Input LOW Voltage  
Input HIGH Current  
2500  
VDD  
mV  
V
V
IIHH  
VIN = VIHH Max.  
VIN = VILL Min.  
750  
µA  
µA  
[14]  
IILL  
Input LOW Current  
200  
Typ.  
170  
Miscellaneous  
Max.  
[15]  
IDD  
Power Supply Current  
Freq. = Max.  
Commercial  
250  
mA  
Capacitance[16]  
Parameter  
CINTTL  
CINPECL  
Notes:  
Description  
TTL Input Capacitance  
PECL input Capacitance  
Test Conditions  
TA = 25°C, f0 = 1 MHz, VDD = 5.0V  
TA = 25°C, f0 = 1 MHz, VDD = 5.0V  
Max.  
7
4
Unit  
pF  
pF  
13. Tested one output at a time, output shorted for less than one second, less than 10% duty cycle.  
14. To guarantee positive currents for all PECL voltages, an external pull-down resistor must be present.  
15. Maximum ICC is measured with VDD = MAX, RFEN = LOW, and outputs unloaded. Typical IDD is measured with VDD = 5.0V, TA = 25°C, RFEN = LOW, and  
outputs unloaded.  
16. Tested initially and after any design or process changes that may affect these parameters, but not 100% tested.  
Document #: 38-02020 Rev. *C  
Page 21 of 46  
CY7C9689A  
AC Test Loads and Waveforms  
5.0V  
R1  
R2  
OUTPUT  
VDD 1.3  
R1=500Ω  
R =50Ω  
L
C
L
R
L
C
R2=333Ω  
C < 5 pF  
L
L
C 10 pF  
(Includes fixture and  
probe capacitance)  
L
(Includes fixture and  
probe capacitance)  
(a) TTL AC Test Load[17]  
(b) PECL AC Test Load [17]  
V
IHE  
3.0V  
2.0V  
V
3.0V  
V =1.5V  
IHE  
2.0V  
0.8V  
80%  
80%  
V =1.5V  
th  
th  
20%  
250 ps  
20%  
250 ps  
0.8V  
V
ILE  
0.0V  
< 1 ns  
V
ILE  
< 1 ns  
(c) TTL Input Test Waveform  
(d) PECL Input Test Waveform  
CY7C9689A Transmitter TTL Switching Characteristics, FIFO Enabled Over the Operating Range  
Parameter  
fTS  
Description  
TXCLK Clock Cycle Frequency With Transmit FIFO Enabled  
TXCLK Period  
Min.  
Max.  
Unit  
MHz  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
50  
tTXCLK  
20  
6.5  
6.5  
0.7  
0.7  
2
tTXCPWH  
tTXCPWL  
TXCLK HIGH Time  
TXCLK LOW Time  
TXCLK Rise Time[18]  
TXCLK Fall Time[18]  
[16]  
tTXCLKR  
5
5
[16]  
tTXCLKF  
tTXA  
Flag Access Time From TXCLKto Output  
Transmit Data Set-up Time to TXCLK↑  
Transmit Data Hold Time from TXCLK↑  
Transmit Enable Set-up Time to TXCLK↑  
Transmit Enable Hold Time from TXCLK↑  
Transmit FIFO Reset (TXRST) Set-up Time to TXCLK↑  
Transmit FIFO Reset (TXRST Hold Time from TXCLK↑  
Transmit Chip Enable (CE) Set-up Time to TXCLK↑  
Transmit Chip Enable (CE) Hold Time from TXCLK↑  
Sample of CE LOW by TXCLK, Output High-Z to Active HIGH or LOW  
Sample of CE LOW by TXCLKto Output Valid  
Sample of CE HIGH by TXCLKto Output in High-Z  
15  
tTXDS  
4
tTXDH  
1
tTXENS  
tTXENH  
tTXRSS  
tTXRSH  
tTXCES  
tTXCEH  
tTXZA  
4
1
4
1
4
1
0
tTXOE  
1.5  
1.5  
20  
20  
tTXAZ  
Notes:  
17. Cypress uses constant current (ATE) load configurations and forcing functions. This figure is for reference only.  
18. Input/output rise and fall time is measured between 0.8V and 2.0V  
Document #: 38-02020 Rev. *C  
Page 22 of 46  
CY7C9689A  
CY7C9689A Receiver TTL Switching Characteristics, FIFO Enabled Over the Operating Range  
Parameter  
fRIS  
Description  
RXCLK Clock Cycle Frequency With Receive FIFO Enabled  
RXCLK Input Period  
Min.  
Max.  
Unit  
MHz  
ns  
50  
tRXCLKIP  
tRXCPWH  
tRXCPWL  
20  
6.5  
6.5  
0.7  
0.7  
4
RXCLK Input HIGH Time  
ns  
RXCLK Input LOW Time  
RXCLK Input Rise Time[18]  
RXCLK Input Fall Time[18]  
ns  
[16]  
tRXCLKIR  
5
5
ns  
[16]  
tRXCLKIF  
tRXENS  
tRXENH  
tRXRSS  
tRXRSH  
tRXCES  
tRXCEH  
tRXA  
ns  
Receive Enable Set-up Time to RXCLK↑  
Receive Enable Hold Time from RXCLK↑  
Receive FIFO Reset (RXRXT) Set-up Time to RXCLK↑  
Receive FIFO Reset (RXRXT) Hold Time from RXCLK↑  
Receive Chip Enable (CE) Set-up Time to RXCLK↑  
Receive Chip Enable (CE) Hold Time from RXCLK↑  
Flag and Data Access Time From RXCLKto Output  
Sample of CE LOW by RXCLK, Output High-Z to Active HIGH or LOW,[19]  
or Sample of RXEN Asserted by RXCLK, Output High-Z to Active HIGH or LOW  
Sample of CE LOW by RXCLKto Output Valid,[19]  
ns  
1
ns  
4
ns  
1
ns  
4
ns  
1
ns  
1.5  
0
15  
ns  
tRXZA  
ns  
tRXOE  
tRXZA  
1.5  
1.5  
20  
20  
ns  
ns  
or Sample of RXEN Asserted by RXCLKto RXDATA Outputs Valid  
Sample of CE HIGH by RXCLKto Output in High-Z,[19]  
or Sample of RXEN Asserted by RXCLKto RXDATA Outputs in High-Z  
CY7C9689A Transmitter TTL Switching Characteristics, FIFO Bypassed Over the Operating Range  
Parameter  
tTRA  
Description  
Min.  
2
Max.  
Unit  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
Flag Access Time From REFCLKto Output  
Write Data Set-up Time to REFCLK↑  
15  
tREFDS  
4
tREFDH  
Write Data Hold Time from REFCLK↑  
2
tREFENS  
tREFENH  
tREFCES  
tREFCEH  
tREFZA  
Transmit Enable Set-up Time to REFCLK↑  
4
Transmit Enable Hold Time from REFCLK↑  
2
Transmit Chip Enable (CE) Set-up Time to REFCLK↑  
Transmit Chip Enable (CE) Hold Time from REFCLK↑  
Sample of CE LOW by REFCLK, Output High-Z to Active HIGH or LOW  
Sample of CE LOW by REFCLKto Flag Output Valid  
Sample of CE HIGH by REFCLKto Flag Output High-Z  
4
2
0
tREFOE  
tREFAZ  
1.5  
1.5  
20  
20  
CY7C9689A Receiver TTL Switching Characteristics, FIFO Bypassed Over the Operating Range  
Parameter  
Description  
Min.  
Max.  
Unit  
[20]  
fROS  
RXCLK Clock Output Frequency100 to 200 MBaud 8-bit Operation  
10  
20  
MHz  
(SPDSEL is HIGH and BYTE8/10 is HIGH)  
RXCLK Clock Output Frequency50 to 100 MBaud 8-bit Operation  
(SPDSEL is LOW and BYTE8/10 is HIGH)  
5
10  
MHz  
MHz  
MHz  
RXCLK Clock Output Frequency100 to 200 MBaud 10-bit Operation  
(SPDSEL is HIGH and BYTE8/10 is LOW)  
8.33  
4.16  
16.67  
8.33  
RXCLK Clock Output Frequency50 to 100 MBaud 10-bit Operation  
(SPDSEL is LOW and BYTE8/10 is LOW)  
tRXCLKOP  
tRXCLKOD  
RXCLK Output Period  
25  
40  
240  
60  
2
ns  
%
RXCLK Output Duty Cycle  
RXCLK Output Rise Time[18]  
RXCLK Output Fall Time[18]  
Receive Enable Set-up Time to RXCLK↑  
[16]  
tRXCLKOR  
0.25  
0.25  
4
ns  
ns  
ns  
[16]  
tRXCLKOF  
2
tRXENS  
Note:  
19. Parallel data output specifications are only valid if all outputs are loaded with similar DC and AC loads.  
20. The period of tROS will match the period of the transmitter PLL reference (REFCLK) when receiving serial data. When data is interrupted, RXCLK may drift to REFCLK +0.2%.  
Document #: 38-02020 Rev. *C  
Page 23 of 46  
CY7C9689A  
CY7C9689A Receiver TTL Switching Characteristics, FIFO Bypassed Over the Operating Range (continued)  
Parameter  
tRXENH  
Description  
Min.  
Max.  
Unit  
ns  
Receive Enable Hold Time from RXCLK↑  
1
0
tRXZA  
tRXOE  
tRXAZ  
Sample of CE LOW by RXCLK, Outputs High-Z to Active  
Sample of RXEN Asserted by RXCLKto RXDATA Outputs High-Z to Active  
ns  
Sample of CE LOW by RXCLKto Flag Output Valid  
Sample of RXEN Asserted by RXCLKto RXDATA Output Low-Z  
1.5  
1.5  
20  
20  
ns  
ns  
Sample of CE HIGH by RXCLKto Flag Output High-Z  
Sample of RXEN Deasserted by RXCLKto RXDATA Output High-Z  
CY7C9689A REFCLK Input Switching Characteristics Over the Operating Range  
Conditions  
Parameter  
Description  
SPDSEL RANGESEL BYTE8/10 Min.  
Max. Unit  
fREF  
REFCLK Clock Frequency50 to 100 MBaud,  
10-bit Mode, REFCLK = 2x Character Rate  
0
0
0
0
1
1
1
1
0
0
1
0
1
0
1
0
1
8.33  
16.67 MHz  
REFCLK Clock Frequency50 to 100 MBaud,  
8-bit Mode, REFCLK = 2x Character Rate  
0
10  
20  
33.3  
40  
MHz  
MHz  
MHz  
REFCLK Clock Frequency50 to 100 MBaud,  
10-bit Mode, REFCLK = 4x Character Rate  
1[21]  
1[21]  
0
16.67  
20  
REFCLK Clock Frequency50 to 100 MBaud,  
8-bit Mode, REFCLK = 4x Character Rate  
REFCLK Clock Frequency100 to 200 MBaud,  
10-bit Mode, REFCLK = Character Rate  
8.33  
10  
16.67 MHz  
REFCLK Clock Frequency100 to 200 MBaud,  
8-bit Mode, REFCLK = Character Rate  
0
20  
33.3  
40  
MHz  
MHz  
MHz  
REFCLK Clock Frequency100 to 200 MBaud,  
10-bit Mode, REFCLK = 2x Character Rate  
1
16.67  
20  
REFCLK Clock Frequency100 to 200 MBaud,  
1
8-bit Mode, REFCLK = 2x Character Rate  
tREFCLK  
tREFH  
REFCLK Period  
25  
6.5  
120  
ns  
ns  
ns  
%
REFCLK HIGH Time  
REFCLK LOW Time  
REFCLK Frequency Referenced to Received Clock Period[22]  
tREFL  
6.5  
tREFRX  
0.04  
+0.04  
CY7C9689A Receiver Switching Characteristics Over the Operating Range  
Parameter  
[23]  
Description  
Min.  
Max.  
Unit  
ns  
tB  
Bit Time  
20.0  
5.0  
tSA  
Static Alignment[16, 24]  
Error Free Window[16, 25, 26]  
600  
ps  
tEFW  
0.65  
UI  
tIN_J  
IN± Peak-to-Peak Input Jitter Tolerance[16, 25, 27, 28]  
0.5  
UI  
Notes:  
21. When configured for synchronous operation with the FIFOs bypassed (FIFOBYP is LOW), if RANGESEL is HIGH the SPDSEL input is ignored and operation  
is forced to the 100200 MBaud range.  
22. REFCLK has no phase or frequency relationship with RXCLK and only acts as a centering reference to reduce clock synchronization time. REFCLK must be  
within ±0.04% of the transmitter PLL reference (REFCLK) frequency, necessitating a ±200-PPM crystal.  
23. The PECL switching threshold is the midpoint between the PECLVOH, and VOL specification (approximately VDD 1.33V).  
24. Static alignment is a measure of the alignment of the Receiver sampling point to the center of a bit. Static alignment is measured by the absolute difference  
of the left and right edge shifts (|tSH_L tSH_R|) of one bit until a character error occurs.  
25. Receiver UI (Unit Interval) is calculated as 1/(fREF*N) when operated in 8-bit mode (N = 10) and 10-bit mode (N = 12) if no data is being received, or 1/(fREF*N)  
of the remote transmitter if data is being received. In an operating link this is equivalent to N * tB when REFCLK = 1X the character rate. An alternate multiply  
ratios (2X or 4X, as selected by SPDSEL and RANGESEL), the numerator is multiplied by 2 or 4 respectively.  
26. Error Free Window is a measure of the time window between bit centers where a transition may occur without causing a bit sampling error. EFW is measured  
over the operating range, input jitter < 50% Dj.  
27. The specification is sum of 25% Duty Cycle Distortion (DCD), 10% Data Dependant Jitter (DDJ), 15% Random Jitter (RJ).  
28. Parallel data output specifications are only valid if all outputs are loaded with similar DC and AC loads.  
Document #: 38-02020 Rev. *C  
Page 24 of 46  
CY7C9689A  
CY7C9689A Transmitter Switching Characteristics Over the Operating Range  
Parameter  
Description  
Min.  
20.0  
200  
200  
Max.  
5.0  
Unit  
ns  
[23]  
tB  
Bit Time  
tRISE  
tFALL  
tDJ  
PECL Output Rise Time 2080% (PECL Test Load)[16]  
PECL Output Fall Time 8020% (PECL Test Load)[16]  
Deterministic Jitter (peak-peak)[16, 29]  
1700  
1700  
0.02  
0.008  
0.08  
ps  
ps  
UI  
tRJ  
Random Jitter (σ)[16, 30]  
UI  
tJT  
Transmitter Total Output Jitter (peak-peak)[16]  
UI  
CY7C9689A HOTLink Transmitter Switching Waveforms  
Write Cycle  
Asynchronous (FIFO) Interface  
EXTFIFO = HIGH  
tTXCLK  
FIFOBYP = HIGH  
tTXCPWH  
tTXCPWL  
TXCLK  
tTXDS  
tTXDH  
TXHALT  
TXSC/D  
TXDATA[7:0]  
Note 31  
TXDATA[9:8]/TXCMD[2:3]  
TXCMD[1:0]  
tTXENH  
NO OPERATION  
TXEN  
tTXENS  
t
TXA  
t
TXA  
TXFULL  
TXHALF  
TXEMPTY  
Write Cycle  
Asynchronous (FIFO) Interface  
EXTFIFO = LOW  
FIFOBYP = HIGH  
TXCLK  
tTXDS  
tTXDH  
TXHALT  
TXSC/D  
TXDATA[7:0]  
Note 32  
TXDATA[9:8]/TXCMD[2:3]  
TXCMD[1:0]  
tTXENH  
tTXENS  
TXEN  
NO OPERATION  
t
TXA  
TXFULL  
TXHALF  
TXEMPTY  
tTXA  
Notes:  
29. While sending continuous JK, outputs loaded to 50to VDD 1.3V, over the operating range.  
30. While sending continuous HH, after 100,000 samples measured at the cross point of differential outputs, time referenced to REFCLK input, over the operating range.  
31. When EXTFIFO is HIGH, the write data is captured on the clock cycle following TXEN = HIGH.  
32. When EXTFIFO is LOW, the write data is captured on the same clock cycle as the TXEN = LOW.  
Document #: 38-02020 Rev. *C  
Page 25 of 46  
CY7C9689A  
CY7C9689A HOTLink Transmitter Switching Waveforms (continued)  
OUTPUT ENABLE Timing  
Asynchronous (FIFO) Interface  
EXTFIFO = HIGH  
FIFOBYP = HIGH  
TXCLK  
TXHALT  
TXSC/D  
TXDATA[7:0]  
TXDATA[9:8]/TXCMD[2:3]  
TXCMD[1:0]  
NO OPERATION  
TXEN  
Note 33  
tTXRSS  
tTXRSH  
TXRST  
CE  
tTXCES  
tTXCEH  
tTXOAZ  
tTXOE  
TXFULL  
TXHALF  
TXEMPTY  
tTXOZA  
OUTPUT ENABLE Timing  
Asynchronous (FIFO) Interface  
EXTFIFO = LOW  
FIFOBYP = HIGH  
TXCLK  
TXHALT  
TXSC/D  
TXDATA[7:0]  
XDATA[9:8]/TXCMD[2:3]  
TXCMD[1:0]  
TXEN  
NO OPERATION  
tTXRSH  
tTXRSS  
Note 33  
CE  
TXRST  
tTXCES  
tTXCEH  
CE  
TXRST  
tTXOAZ  
tTXOE  
TXFULL  
TXHALF  
TXEMPTY  
tTXOZA  
Note:  
33. Illustrates timing only. TXEN and TXRST not usually active in same time period.  
Document #: 38-02020 Rev. *C  
Page 26 of 46  
CY7C9689A  
CY7C9689A HOTLink Transmitter Switching Waveforms (continued)  
Write Cycle  
Synchronous Interface  
tREFCLK  
EXTFIFO = HIGH  
tREFH  
tREFL  
FIFOBYP = LOW  
REFCLK  
TXHALT  
tREFDS  
tREFDH  
TXSC/D  
TXDATA[7:0]  
Note 34  
XDATA[9:8]/TXCMD[2:3]  
TXCMD[1:0]  
tREFENH  
NO OPERATION  
TXEN  
tREFENS  
tTRA  
tTRA  
TXFULL  
TXHALF  
TXEMPTY  
Write Cycle  
Synchronous Interface  
EXTFIFO = LOW  
FIFOBYP = LOW  
REFCLK  
tREFDS  
tREFDH  
TXHALT  
TXSC/D  
Note 35  
TXDATA[7:0]  
DATA[9:8]/TXCMD[2:3]  
TXCMD[1:0]  
tREFENH  
tREFENS  
TXEN  
NO OPERATION  
TXFULL  
TXHALF  
TXEMPTY  
Notes:  
34. When transferring data to the Transmitter input from a depth expanded external FIFO, the data is captured from the external FIFO one clock cycle following the  
actual enable (TXEN = HIGH).  
35. When transferring data to the Transmitter input from a synchronous external controller, the data is captured in the same clock cycle as the actual enable (TXEN  
= LOW).  
Document #: 38-02020 Rev. *C  
Page 27 of 46  
CY7C9689A  
CY7C9689A HOTLink Transmitter Switching Waveforms (continued)  
OUTPUT ENABLE Timing  
Synchronous Interface  
EXTFIFO = HIGH  
FIFOBYP = LOW  
REFCLK  
TXHALT  
TXSC/D  
TXDATA[7:0]  
TXDATA[9:8]/TXCMD[2:3]  
tREFENH  
TXCMD[1:0]  
NO OPERATION  
TXEN  
tREFENS  
tREFCEH  
tREFCES  
CE  
tREFAZ  
tREFOE  
TXFULL  
TXEMPTY  
tREFZA  
OUTPUT ENABLE Timing  
Synchronous Interface  
EXTFIFO = LOW  
FIFOBYP = LOW  
REFCLK  
TXHALT  
TXSC/D  
TXDATA[7:0]  
TXDATA[9:8]/TXCMD[2:3]  
TXCMD[1:0]  
NO OPERATION  
TXEN  
CE  
TXFULL  
TXEMPTY  
Document #: 38-02020 Rev. *C  
Page 28 of 46  
CY7C9689A  
CY7C9689A HOTLink Receiver Switching Waveforms  
Read Cycle  
Asynchronous (FIFO) Interface  
EXTFIFO = HIGH  
tRXCLKOP  
tRXCLKIP  
FIFOBYP = HIGH  
tRXCLKOD  
tRXCPWH  
tRXCLKOD  
tRXCPWL  
RXCLK  
tRXENS  
tRXENH  
RXEN  
NO OPERATION  
READ  
READ  
tRXA  
tRXA  
Note 36  
RXEMPTY  
RXFULL  
FIFO EMPTY  
RXHALF  
RXDATA[7:0]  
VALID DATA  
Note 37  
RXDATA[9:8/RXCMD[2:3]  
RXCMD[1:0]  
CE  
Read Cycle  
Asynchronous (FIFO) Interface  
EXTFIFO = LOW  
FIFOBYP = HIGH  
RXCLK  
tRXENS  
tRXENH  
READ  
RXEN  
tRXA  
tRXA  
FIFO EMPTY  
RXEMPTY  
RXFULL  
RXHALF  
VALID DATA  
Note 38  
RXDATA[7:0]  
RXDATA[9:8/RXCMD[2:3]  
RXCMD[1:0]  
CE  
Notes:  
36. When transferring data from the Receive FIFO to a depth expanded external FIFO, the data is sent to the external FIFO on the same clock cycle that RXEN =  
HIGH. RXEMPTY = LOW indicates that data is available.  
37. On inhibited reads, or if the Receive FIFO goes empty, the data outputs do not change.  
38. When reading data from synchronous data interface, the data is captured on any clock cycle that RXEN = LOW. RXEMPTY = HIGH indicates data is available.  
RXEMPTY = LOW indicates that the FIFO is empty.  
Document #: 38-02020 Rev. *C  
Page 29 of 46  
CY7C9689A  
CY7C9689A HOTLink Receiver Switching Waveforms (continued)  
Output Enable Timing  
RXCLK  
tRXENH  
tRXENS  
RXEN  
NO OPERATION  
Note 39  
tRXRSS  
tRXRSH  
RXRST  
CE  
tRXCES  
tRXCEH  
tRXAZ  
Note 40  
tRXOE  
RXFULL  
RXDATA[7:0]  
OLD DATA  
RXDATA[9:8/RXCMD[2:3]  
RXCMD[1:0]  
tRXZA  
t
REFCLK  
t
REFL  
t
REFH  
REFCLK  
Static Alignment  
Error-Free Window  
t /2t  
B
SA  
t /2t  
B
SA  
t
EFW  
INA±  
INB±  
INA±  
INB±  
t
B
BIT CENTER  
BIT CENTER  
SAMPLE WINDOW  
Table 7. HOTLink TAXI-compatible Encoder Patterns  
4B/5B Encoder  
5B/6B Encoder  
5-bit Binary  
HEX  
Data  
4-bit Binary  
Data[41]  
5-bit Encoded  
Symbol[42, 43]  
HEX  
Data  
6-bit Encoded  
Symbol[42, 43]  
Data[41]  
00000  
00001  
00010  
00011  
00100  
00101  
0
1
2
3
4
5
0000  
0001  
0010  
0011  
0100  
0101  
11110  
01001  
10100  
10101  
01010  
01011  
00  
01  
02  
03  
04  
05  
110110  
010001  
100100  
100101  
010010  
010011  
Notes:  
39. Illustrates timing only. RXEN and RXRST not usually active in same time period.  
40. Receive FIFO Reads are inhibited while the outputs are High-Z.  
41. Binary Input Data is the parallel input data which is input to the Transmitter and output from the Receiver. Binary bits are listed from left to right in the following  
order: 8-Bit mode (BYTE8/10 is HIGH and TXSC/D or RXSC/D is LOW)TXDATA/RXDATA[7], [6], [5], [4], and TXDATA/RXDATA[3], [2], [1], [0]; 10-Bit mode  
(BYTE8/10 is LOW and TXSC/D or RXSC/D is LOW)TXDATA/RXDATA[8], [7], [6], [5], [4], and TXDATA/RXDATA[9], [3], [2], [1], [0].  
42. The ENCODED Symbols are shown here as ones and zeros, but are converted to and from an NRZI stream at the transmitter output and receiver input.  
NRZI represents a oneas a state transition (either LOW-to-HIGH or HIGH-to-LOW) and a zeroas no transition within the bit interval.  
43. Encoded Serial Symbol bits are shifted out with the most significant bit (Left-most) of the most significant nibble coming out first.  
Document #: 38-02020 Rev. *C  
Page 30 of 46  
CY7C9689A  
Table 7. HOTLink TAXI-compatible Encoder Patterns (continued)  
4B/5B Encoder  
5B/6B Encoder  
5-bit Binary  
HEX  
Data  
4-bit Binary  
Data[41]  
5-bit Encoded  
Symbol[42, 43]  
HEX  
Data  
6-bit Encoded  
Symbol[42, 43]  
Data[41]  
00110  
00111  
01000  
01001  
01010  
01011  
01100  
01101  
01110  
01111  
10000  
10001  
10010  
10011  
10100  
10101  
10110  
10111  
10001  
11001  
11010  
11011  
11100  
11101  
11110  
11111  
6
7
0110  
0111  
1000  
1001  
1010  
1011  
1100  
1101  
1110  
1111  
01110  
01111  
10010  
10011  
10110  
10111  
11010  
11011  
11100  
11101  
06  
07  
08  
09  
0A  
0B  
0C  
0D  
0E  
0F  
10  
11  
010110  
010111  
100010  
110001  
110111  
100111  
110010  
110011  
110100  
110101  
111110  
011001  
101001  
101101  
011010  
011011  
011110  
011111  
101010  
101011  
101110  
101111  
111010  
111011  
111100  
111101  
8
9
A
B
C
D
E
F
12  
13  
14  
15  
16  
17  
18  
19  
1A  
1B  
1C  
1D  
1E  
1F  
Table 8. HOTLink TAXI Compatible Command Symbols  
CY7C9689A (Transmitter)  
CY7C9689A (Receiver)  
Command Input  
TXCMD[3:0]  
Command Output  
RXCMD[3:0]  
Encoded  
HEX  
8-bit mode (BYTE8/10 is HIGH)  
Binary CMD[44]  
Symbol[42, 43]  
Mnemonic  
HEX  
Binary CMD[44]  
0
1
2
3
4
5
6
7
0000  
0001  
0010  
0011  
0100  
0101  
0110  
0111  
11000 10001  
11111 11111  
01101 01101  
01101 11001  
11111 00100  
01101 00111  
11001 00111  
11001 11001  
JK (8-bit SYNC)  
0
1
2
3
4
5
6
7
0000  
0001  
0010  
0011  
0100  
0101  
0110  
0111  
II  
TT  
TS  
IH  
TR  
SR  
SS  
Note:  
44. Binary CMD is the parallel input data which is input to the Transmitter and output from the Receiver. Binary bits are listed from left to right in the following order:  
8-Bit mode (BYTE8/10 is HIGH and TXSC/D or RXSC/D is HIGH)TXCMD/RXCMD[3], [2], [1], [0]; 10-Bit mode (BYTE8/10 is LOW and TXSC/D or RXSC/D  
is HIGH)TXCMD/RXCMD[1], [0].  
Document #: 38-02020 Rev. *C  
Page 31 of 46  
CY7C9689A  
Table 8. HOTLink TAXI Compatible Command Symbols (continued)  
CY7C9689A (Transmitter)  
CY7C9689A (Receiver)  
Command Input  
TXCMD[3:0]  
Command Output  
RXCMD[3:0]  
8[45]  
9[45]  
A[45]  
B
1000  
1001  
1010  
1011  
1100  
1101  
1110  
1111  
00100 00100  
00100 11111  
00100 00000  
00111 00111  
00111 11001  
00000 00100  
00000 11111  
00000 00000  
HH  
HI  
8
9
1000  
1001  
1010  
1011  
1100  
1101  
1110  
1111  
HQ  
RR  
RS  
QH  
QI  
A
B
C
D
E
F
C
D[45]  
E[45]  
F[45]  
QQ  
10-bit mode (BYTE8/10 is LOW)  
0
1
2
3
00  
01  
10  
11  
011000 100011  
111111 111111  
011101 011101  
011101 111001  
LM (10-bit SYNC)  
0
1
2
3
00  
01  
10  
11  
II’  
TT’  
TS’  
8-bit characters  
10-bit characters  
10-bit pre-encoded characters (pre-scrambled or  
pre-encoded)  
12-bit pre-encoded characters (pre-scrambled or  
pre-encoded).  
Functional Description  
The interconnection of two or more CY7C9689A Transceivers  
forms a general-purpose communications subsystem capable  
of transporting user data at up to 20 MBytes per second over  
several types of serial interface media. The CY7C9689A is  
highly configurable with multiple modes of operation.  
The bit numbering and content of the parallel transmit interface  
is shown in Table 1. When operated with the 4B/5B, 5B/6B  
Encoder bypassed, the TXSC/D and RXSC/D bits are ignored.  
In the transmit section of the CY7C9689A, data moves from  
the input register, through the Transmit FIFO, to the 4B/5B  
Encoder. The encoded data is then shifted serially out the  
OUTx± differential PECL compatible drivers. The bit-rate clock  
is generated internally from a 2.5x, 5x, or 10x PLL clock multi-  
plier. A more complete description is found in the section  
CY7C9689A HOTLink Transmit-Path Operating Mode  
Description.  
The HOTLink Transceiver serial interface provides a seamless  
interface to various types of media. A minimal number of  
external passive components are required to properly  
terminate transmission lines and provide LVPECL loads. For  
power supply decoupling, a single capacitor (in the range of  
0.02 µF to 0.1 µF) is required per power/ground pair. Additional  
information on interfacing these components to various media  
can be found in the HOTLink Design Considerations appli-  
cation note.  
In the receive section of the CY7C9689A, serial data is  
sampled by the receiver on one of the INx± differential line  
receiver inputs. The receiver clock and data recovery PLL  
locks onto the selected serial bit stream and generates an  
internal bit-rate sample clock. The bit stream is deserialized,  
decoded, and presented to the Receive FIFO, along with a  
character clock. The data in the FIFO can then be read either  
slower or faster than the incoming character rate. A more  
complete description is found in the section CY7C9689A  
HOTLink Receive-Path Operating Mode Description.  
CY7C9689A TAXI HOTLink Transmit-Path  
Operating Mode Descriptions  
The TAXI HOTLink Transmitter can be configured into several  
operating modes, each providing different capabilities and  
fitting different transmission needs. These modes are selected  
using the FIFOBYP, ENCBYP and BYTE8/10 inputs on the  
CY7C9689A Transceiver. These modes can be reduced to five  
primary classes:  
The Transmitter and Receiver parallel interface timing and  
functionality can be configured to Cascade directly to external  
FIFOs for depth expansion, couple directly to registers, or  
couple directly to state machines. These interfaces can accept  
or output either:  
Synchronous Encoded  
Synchronous Pre-encoded  
Asynchronous Encoded  
Asynchronous Pre-encoded.  
Note:  
45. While these Commands are legal data and will not disrupt normal operation if used occasionally, they may cause data errors if grouped into recurrent fields.  
Normal PLL operation cannot be guaranteed if one or more of these commands is continuously repeated.  
Document #: 38-02020 Rev. *C  
Page 32 of 46  
CY7C9689A  
Synchronous Encoded  
FIFO and Encoder are enabled, the input FIFO may be loaded  
at any rate supported by the FIFO (up to 50 MHz), without  
generating any decoder errors at the receive end of the link.  
In this mode, the Transmit FIFO is bypassed, while the 4B/5B,  
5B/6B encoder is enabled. One character is accepted at the  
Transmit Input Register at the rising edge of REFCLK, and  
passed to the Encoder where it is encoded for serial trans-  
mission. The Serializer operates synchronous to REFCLK,  
which is multiplied by 10 or 5 to generate the serial data  
bit-clock. In this mode the TXRST and TXHALT inputs are not  
interpreted and may be tied either HIGH or LOW. To place the  
CY7C9689A into synchronous modes, FIFOBYP must be  
LOW.  
CY7C9689A TAXI HOTLink Receive-Path  
Operating Mode Descriptions  
The HOTLink Receiver can be configured into several  
operating modes, each providing different capabilities and  
fitting different reception needs. These modes are selected  
using the FIFOBYP, ENCBYP, BYTE8/10 inputs on the  
CY7C9689A Transceiver. These modes can be reduced to  
four primary classes:  
This mode is usually used for products that must meet specific  
predefined protocol requirements, and cannot tolerate the  
uncontrolled insertion of SYNC fill characters. The host  
system is required to provide new data at every rising edge of  
REFCLK (along with TXEN) to maintain the data stream. If  
TXEN is not asserted, the Encoder is loaded with JK or LM  
sync characters.  
Synchronous Decoded  
Synchronous Undecoded  
Asynchronous Decoded  
Asynchronous Undecoded.  
In all these modes, serial data is received at one of the differ-  
ential line receiver inputs and routed to the Deserializer and  
Framer. The PLL in the clock and data recovery block is used  
to extract a bit-rate clock from the transitions in the data  
stream, and uses that clock to capture bits from the serial  
stream. These bits are passed to the Deserializer where they  
are formed into 10- or 12-bit characters.  
Input Register Mapping  
In Encoded modes, the bits of the TXDATA input bus are  
mapped into characters (as shown in Table 1), including a  
TXSVS bit, eight bits of data, and a TXSC/D bit to select either  
Special Character codes or Data characters.  
To align the incoming bit stream to the proper character bound-  
aries, the Framer must be enabled by asserting RFEN HIGH.  
The Framer logic-block checks the incoming bit stream for the  
unique pattern that defines the character boundaries. This  
logic filter looks for the JK or LM (when BYTE8/10 is LOW)  
sync character. Once a sync character is found, the Framer  
captures the offset of the data stream from the present  
character boundaries, and resets the boundary to reflect this  
new offset, thus framing the data to the correct character  
boundaries.  
The TXSC/D bit controls the encoding of the TXDATA[7:0] or  
TXDATA[9:0] bits of each character. It is used to identify if the  
input character represents a Data Character or a Special  
Character code. If TXSC/D is LOW, the character appeared on  
the TXDATA bus is encoded using the Data Character codes  
listed in Table 7. If TXSC/D is HIGH, the character on the  
TXCMD bus is encoded using the Special Character codes  
listed in Table 8.  
Synchronous Pre-encoded  
In synchronous pre-encoded mode, both the Transmit FIFO  
and the 4B/5B encoder are bypassed, and data passes directly  
from the Transmit Input Register to the Serializer. The  
Serializer operates synchronous to REFCLK, which is multi-  
plied by 10 or 5 when BYTE8/10 is HIGH (as selected by the  
SPDSEL and RANGESEL inputs) to generate the serial data  
bit-clock. In this mode, part of the TXCMD bus inputs are used  
as part of the data input bus. To place the CY7C9689A into  
synchronous modes, FIFOBYP must be LOW.  
Since noise induced errors can cause the incoming data to be  
corrupted, and since many combinations of corrupt and legal  
data can create an aliased sync character, the framer may also  
be disabled by deasserting RFEN LOW.  
Synchronous Decoded  
In these modes, the Receive FIFO is bypassed, while the  
5B/4B, 6B/5B Decoder is enabled. Framed characters output  
from the Deserializer are decoded, and passed directly to the  
Receive Output Register. The Deserializer operates  
synchronous to the recovered bit-clock, which is divided by 10,  
generate the output RXCLK clock. In this mode the RXRST  
input is not interpreted and may be biased either HIGH or  
LOW.  
This mode is usually used for products containing external  
encoders or scramblers, that must meet specific protocol  
requirements. The host system is required to provide new data  
at every rising edge of the REFCLK (along with TXEN) to  
maintain the data stream. If TXEN is not asserted, the  
Serializer is loaded with JK or LM sync characters.  
These modes are usually used for products that must meet  
specific protocol requirements. New decoded characters are  
provided at the RXDATA outputs once every rising edge of  
RXCLK. If RXEMPTY is asserted LOW, the characters on the  
RXCMD output register is a JK or LM sync character, and the  
discard policy is set to non-0. Because the decoder is now  
enabled, all received characters are checked for compliance  
to the 4B/5B decoding rules.  
In this mode the LSB of each input character (TXDATA[0]) is  
shifted out first, followed sequentially by TXDATA[1] through  
TXDATA[9] (TXDATA[11] when BYTE8/10 is LOW).  
Asynchronous Encoded  
In Asynchronous Encoded mode, both the Transmit FIFO and  
the Encoder are enabled. This provides 256 characters of data  
buffering. The Serializer operates synchronous to REFCLK,  
which is multiplied by 2.5, 5, or 10 to generate the serial data  
bit-clock (as selected by SPDSEL and RANGESEL). In this  
mode the TXRST and TXHALT inputs are interpreted.  
Output Register Mapping  
The RXDATA[11:0] output bus is mapped into a character  
consisting of eight bits of data and four bits of command, or ten  
bits of data and two bits of command. An accompanying  
RXSC/D bit identifies the character as either command or  
data.  
This mode supports the same Input Register mapping as  
Synchronous Encoded mode. Because both the Transmit  
Document #: 38-02020 Rev. *C  
Page 33 of 46  
CY7C9689A  
The Violation (VLTN) output indicates a code violation has  
occured. When the VLTN output is asserted HIGH, this  
indicates a transmission error is detected in the character at  
the current transfer clock cycle.  
serial interface are written to the Receive FIFO before being  
passed to the output register. The Deserializer operates  
synchronous to the recovered bit-clock, which is divided by 10  
(or 12) to generate the Receive FIFO write clock. Data is read  
from the Receive FIFO, using the RXCLK input clock, when  
addressed by CE and selected by RXEN.  
Synchronous Undecoded  
In this mode, both the Receive FIFO and the 5B/4B, 6B/5B  
Decoder are bypassed, and data passes directly from the  
Deserializer to the output register. The Deserializer operates  
synchronous to the recovered bit-clock, which is divided by 10  
to generate the output RXCLK clock. In this mode the RXRST  
input is not interpreted and may be biased either HIGH or  
LOW.  
These modes are usually used for products containing  
external decoders or descramblers, that must meet specific  
protocol requirements. New data may be read from the  
Receive FIFO any time that the FIFO status flags indicate a  
non-empty condition (RXEMPTY is deasserted). To ensure  
that data is not lost, the Receive FIFO must be read faster than  
data is loaded into the Receive FIFO.  
This mode is usually used for products containing external  
decoders or descramblers that must meet specific protocol  
requirements. New data is provided at the RXDATA outputs  
once every rising edge of RXCLK. Received characters are  
not checked for any specific coding requirements and no  
decoding errors are reported.  
If the receiver is to provide framed characters, it is necessary  
for the transmit end to include JK or LM sync characters in the  
data stream. This can be done by:  
operating the transmitter in encoded mode and writing JK  
or LM characters into the data stream  
operating the transmitter in pre-encoded mode and writing  
the 10-bit value for an encoded JK (1100010001) or LM  
(011000100011) character to the data stream  
Asynchronous Decoded  
In Asynchronous Decoded mode, both the Receive FIFO and  
the Decoder of the CY7C9689A are enabled. The deserializer  
operates synchronous to the recovered bit-clock, which is  
divided by 10 to generate the Receive FIFO write clock.  
Characters are read from the Receive FIFO, using the external  
RXCLK input, when addressed by CE and selected by RXEN.  
In this mode the RXRST input is interpreted.  
not enabling the transmitter when it is operated in  
synchronous mode, or by allowing the transit FIFO to go  
empty when it is operated in asynchronous mode.  
BIST Operation and Reporting  
The CY7C9689ADX HOTLink Transceiver incorporates the  
same Built-In Self-Test (BIST) capability. This link diagnostic  
uses a Linear Feedback Shift Register (LFSR) to generate a  
511-character repeating sequence that is compared,  
character-for-character, at the receiver.  
Asynchronous Decoded mode supports the same Output  
Register mapping as the Synchronous Decoded mode.  
Because both the Receive FIFO and Decoder are enabled, the  
output FIFO may be read at any rate supported by the FIFO,  
however, if the Receive FIFO ever indicates a full condition  
(RXFULL is asserted), data may be lost.  
BIST mode is intended to check the entire high-speed serial  
link at full link-speed, without the use of specialized and  
expensive test equipment. The complete sequence of  
characters used in BIST are documented in Table 4.  
Asynchronous Undecoded  
In Asynchronous Undecoded modes, the Receive FIFO is  
enabled. This means that all characters received from the  
Document #: 38-02020 Rev. *C  
Page 34 of 46  
CY7C9689A  
TXCLK  
Enable TX BIST  
Start of TX BIST  
TXBISTEN  
TXEMPTY  
TXHALF  
BIST  
LOOP  
OUTA±  
OUTB±  
TXFULL  
TXCMD[1:0]  
TXSC/D  
Dont Care  
TXDATA[9:0]  
TXEN  
REFCLK  
LOW to enable FIFO Flags CE  
LOW to enable VLTN reads  
RXEN  
RXDATA[9:0]  
Ignore these outputs  
ERROR  
RXSC/D  
RXCMD[1:0]  
VLTN  
INA±  
INB±  
RXEMPTY  
RXHALF  
RXFULL  
Forced to indicate EMPTY by BIST  
Start of RX  
BIST match  
Start of RX  
BIST Wait  
BIST  
LOOP  
Enable RX BIST  
RXBISTEN  
RXCLK  
A/B  
HIGH to select A  
Figure 5. Built-In Self-Test Illustration  
BIST Enable Inputs  
as documented, with the exception of the information  
presented on the TXEMPTY FIFO status flag. Since this flag  
is used to present BIST loop status, it continues to reflect the  
state of the transmit BIST loop status until TXBISTEN is no  
longer recognized internally. The completion of the reset  
operation may still be monitored through the TXFULL FIFO  
status flag.  
There are separate BIST enable inputs for the transmit and  
receive paths of the CY7C9689A. These inputs are both active  
LOW; i.e., BIST is enabled in its respective section of the  
device when the BIST enable input is determined to be at a  
logic-0 level. Both BIST enable inputs are asynchronous; i.e.,  
they are synchronized inside the CY7C9689A to the internal  
state machines.  
The TXEMPTY flag, when used for transmit BIST progress  
indication, continues to reflect the active HIGH or active LOW  
settings determined by the UTOPIA or Cascade timing model  
selected by EXTFIFO; i.e., when configured for the Cascade  
timing model, the TXEMPTY and TXFULL FIFO flags are  
active HIGH, when configured for the UTOPIA timing model  
the TXEMPTY and TXFULL FIFO flags are active LOW. The  
illustration in Figure 5 uses the UTOPIA conventions.  
BIST Transmit Path  
The transmit path operation with BIST is controlled by the  
TXBISTEN input and overrides most other inputs (see  
Figure 5). When the Transmit FIFO is enabled (not bypassed)  
and TXBISTEN is recognized internally, all reads from the  
Transmit FIFO are suspended and the BIST generator is  
enabled to sequence out the 511 character repeating BIST  
sequence. If the recognition occurs in the middle of a data  
field, the following data is not transmitted at that time, but  
remains in the Transmit FIFO. Once the TXBISTEN signal is  
removed, the data in the Transmit FIFO is again available for  
transmission. To ensure proper data handling at the desti-  
nation, the transmit host controller should either use TXHALT  
to prevent transmission of data at specific boundaries, or allow  
the Transmit FIFO to completely empty before enabling BIST.  
When TXBISTEN is first recognized, the TXEMPTY flag is  
clocked to a reset state, regardless of the addressed state of  
the Transmit FIFO (if CE is LOW or not), but is not driven out  
of the part unless CE has been sampled asserted (LOW).  
Following this, on each completed pass through the BIST loop,  
the TXEMPTY flag is set for one interface clock period (TXCLK  
or REFCLK).  
The TXEMPTY flag remains set until the interface is  
addressed and the state of TXEMPTY has been observed. If  
the device is not addressed (CE is not sampled LOW), the flag  
remains set internally regardless of the number of TXCLK  
clock cycles that are processed. If the device status is not  
polled on a sufficiently regular basis, it is possible for the host  
system to miss one or more of these BIST loop indications.  
With transmit BIST enabled, the Transmit FIFO remains  
available for loading of data. It may be written up to its normal  
maximum limit while the BIST operation takes place. To allow  
removal of stale data from the Transmit FIFO, it may also be  
reset during a BIST operation. The reset operation proceeds  
Document #: 38-02020 Rev. *C  
Page 35 of 46  
CY7C9689A  
A pass through the loop is defined as that condition where the  
Encoder generates the 0x00 (where 0x denotes Hex number,  
e.g. 0x00 denotes HEX00) state. Depending on the initial state  
of the BIST LFSR, the first pass through the loop may occur at  
substantially less than 511 character periods. Following the  
first pass, as long as TXBISTEN remains LOW, all remaining  
passes are exactly 511 characters in length.  
same as the RXFULL flag, with respect to preserving the  
detection state of an error until it is read.  
Unlike the RXFULL flag, which only needs the CY7C9689A to  
be addressed (CE sampled LOW by RXCLK) to enable the  
RXFULL three-state driver, and an RXCLK to readthe flag,  
the VLTN output requires a selection (assertion of RXEN while  
addressed) to enable the RXDATA bus three-state drivers.  
The selection process is necessary to ensure that a multi-PHY  
implementation does not enable multiple VLTN drivers at the  
same time.  
When the Transmit FIFO is bypassed, the interface is clocked  
by the REFCLK signal instead of TXCLK. While the active or  
asserted state of the TXEMPTY signal is still controlled by the  
EXTFIFO, the state of any completed BIST loops is no longer  
preserved. Instead, the TXEMPTY flag reflects the dynamic  
state of the BIST loop progress, and is asserted only once  
every 511 character periods. If the interface is not addressed  
at the time that this occurs, then the FIFO status flags remain  
in a high-Z state and the loop event is lost.  
When the Receive FIFO is bypassed, the interface is clocked  
by the RXCLK output signal. While the active or asserted state  
of the RXFULL signal is still controlled by the EXTFIFO input,  
the state of any completed BIST loops or detected errors are  
no longer preserved. Instead, the RXFULL flag reflects the  
dynamic state of the BIST loop progress, and is asserted only  
once every 511 character periods. If the interface is not  
addressed at the time that this occurs, then the FIFO status  
flags remain in a high-Z state and the loop event is lost. This  
is also true of the VLTN output, such that if the CY7C9689A  
receive path is not selected to enable the RXDATA bus  
three-state drivers, the detection of a BIST miscompare is lost.  
BIST Receive Path  
The receive path operation in BIST is similar to that of the  
transmit path. While the Receive FIFO is enabled (not  
bypassed) and RXBISTEN is recognized internally, all writes  
to the Receive FIFO are suspended.  
Any data present in the Receive FIFO when RXBISTEN is  
recognized remains in the FIFO and cannot be read until the  
BIST operation is complete. The data in the Receive FIFO  
remains valid, but is NOT available for reading through the  
host parallel interface. This is because the error output  
indicator for receive BIST operations is the VLTN signal, which  
is normally part of the RXDATA bus. To prevent read opera-  
tions while BIST is in operation, the RXEMPTY and RXHALF  
flags are forced to indicate an Empty condition. Once  
RXBISTEN has been removed and recognized internally, the  
Receive FIFO status flags are updated to reflect the current  
content status of the Receive FIFO.  
BIST Three-state Control  
When BIST is enabled on either the transmitter or the receiver,  
the three-state enable signals for the BIST status flags and  
error indicators work the same as for normal data processing.  
The output drivers for the BIST status that is presented on  
FIFO status flags are only enabled when CE has been  
sampled asserted (LOW) by the respective clock (TXCLK,  
RXCLK, or REFCLK).  
To access the BIST error information, it is necessary to  
perform a read cycle of the addressed receiver. This means  
that CE must be LOW to enable the receiver (Rx_Match), and  
RXEN must be asserted from HIGH to LOW to select the  
device. Because the part is in BIST, no data is read from the  
FIFO, but the data bus is driven. This allows the VLTN indicator  
to be driven onto the RXDATA bus. So long as RXEN remains  
asserted, the receiver stays selected, the data bus remains  
driven, and VLTN has meaning.  
To allow removal of stale data from the Receive FIFO, it may  
be reset during a BIST operation. The reset operation  
proceeds as documented, with the exception that the  
RXEMPTY and RXHALF status flags already indicate an  
empty condition. The RXFULL flag is used to present BIST  
progress. The active (asserted) state on RXFULL (and  
RXEMPTY) remain controlled by the present operating mode  
and interface timing model (UTOPIA or Cascade).  
Bus Interfacing  
When RXBISTEN has been recognized, RXFULL becomes  
the receive BIST loop indicator (regardless of the logic state of  
FIFOBYP). When RXBISTEN is first recognized, the RXFULL  
flag is clocked to a set state, regardless of the addressed state  
of the Receive FIFO (if CE is sampled LOW or not). Following  
this, RXFULL remains set until the receiver detects the start of  
the BIST pattern. Then RXFULL is deasserted for the duration  
of the BIST pattern, pulsing asserted for one RXCLK period on  
the last symbol of each BIST loop. If 14 of 28 consecutive  
characters are received in error, RXFULL returns to the set  
state until the start of a BIST sequence is again detected.  
The parallel transmit and receive host interfaces to the  
CY7C9689A are configurable for either synchronous or  
asynchronous operation. Each of these configurations  
supports two selectable timing and control models of Shared  
Bus or Cascade.  
All asynchronous bus configurations have the internal  
Transmit and Receive FIFOs enabled. This allows data to be  
written or read from these FIFOs at any rate up to the  
maximum 50-MHz clock rate of the FIFOs. All internal opera-  
tions of the CY7C9689A do not use the external TXCLK or  
RXCLK, but instead make use of synthesized derivatives of  
REFCLK for transmit path operations and a recovered  
character clock for receive path operations.  
Just like the BIST status flag on the transmit data path, the  
RXFULL flag captures the asserted states, and keeps them  
until they are read. This means that if the status flag is not read  
on a regular basis, events may be lost.  
All synchronous bus configurations require the bus interface  
operations to be synchronous to REFCLK on the transmit path  
and the recovered clock (output as RXCLK) on the receive  
path. The internal FIFOs are bypassed in all synchronous  
modes.  
The detection of errors is presented on the VLTN output.  
Unlike the RXFULL FIFO status flag, the active state of this  
output is not controlled by the EXTFIFO input. With the  
Receive FIFO enabled, these outputs should operate the  
Document #: 38-02020 Rev. *C  
Page 36 of 46  
CY7C9689A  
The two supported timing and control models are Shared Bus  
and Cascade. The Shared Bus is based on the timing model  
of a FIFO with active LOW FIFO status flags and read/write  
enables.  
accesses to Slaves which have room in the TXFIFOs. While  
data is being transferred on the data/command bus, the bus  
Master can continue to poll each Slave device independently.  
Device Selection  
The Cascade timing model is a modification of the Shared Bus  
model that changes the flags and FIFO read/write enables to  
active HIGH. This model is present primarily to allow depth  
expansion of the internal FIFO by direct coupling to external  
CY7C42x5 synchronous FIFOs. To allow this direct coupling,  
the cycle-to-cycle timing between the transmit and receive  
enables (TXEN and RXEN) are also modified to ensure correct  
data transfer.  
All actions on the Shared Bus interface are controlled by the  
Chip Enable and selection states of the interface. These states  
control the read and write access to the Receive and Transmit  
FIFOs, access to the FIFO status flags, reset of the Transmit  
and Receive FIFOs, and read and write access to the Serial  
Address Register. The CY7C9689A supports the concept of  
an address matchthrough a single Chip Enable (CE) input.  
These four configurations of bus operation and timing/control  
can all be used with or without external FIFOs. Depending on  
the specific mode selected, the amount of external hardware  
necessary to properly couple the CY7C9689A to state  
machines or external FIFOs is minimal in all cases, and may  
be zero if the proper configuration is selected.  
Address Match and FIFO Flag Access  
The CY7C9689A makes use of a single active-LOW Chip  
Enable (CE) to generate address-match conditions. This  
allows multiple CY7C9689A devices to share a common bus,  
with device output three-state controls being managed by  
either an address match condition (CE sampled LOW), or by  
a selection state.  
With only minor exceptions, all configurations of the  
CY7C9689A in the Shared Bus mode borrowed concepts from  
the ATM Forums UTOPIA Bus operation. concepts of  
addressing and selection to control the enabled/disabled state  
of the output drivers, and when data can be written to or read  
from the part.  
The Transmit and Receive FIFO flag output drivers are  
enabled in any TXCLK, REFCLK, or RXCLK cycle following  
CE being sampled asserted (LOW) by the rising edge of the  
respective clock. The CE input is sampled separately by the  
clocks for the transmit and receive interfaces, which allows  
these clocks to be both asynchronous to each other, and to  
operate at different clock rates. An example of both Transmit  
and Receive FIFO flag access is shown in Figure 7.  
Shared Bus Interface Concept  
The CY7C9689A Parallel Interface is designed for interfacing  
to a Shared Bus. The maximum TXCLK and RXCLK frequency  
is 50 MHz, which provides a total bandwidth of 50Million  
characters per second in each direction. More than two  
CY7C9689A can be serviced on the same bus at full serial line  
speed.  
TXCLK  
CE  
The CY7C9689A is designed to be the Slave in Master-Slave  
type of shared bus architecture. Generally, the bus Master (a  
Medium Access Device, MAC) is a higher layer device that  
sources out going data/command and sinks incoming  
data/command to/from Slaves (CY7C9689A) on the shared  
bus (see Figure 6).  
TXFULL  
Valid  
Transmit Port Addressing  
Bus  
Master  
RXCLK  
CE  
CEn  
CE1  
CE2  
TXDATA/TXCMD  
RXDATA/RXCMD  
Valid  
Status, Control  
RXEMPTY  
Receive Port Addressing  
Figure 7. FIFO Flag Driver Enables  
............  
CY7C9689A  
CY7C9689A  
CY7C9689A  
Figure 6. Shared Bus Architecture  
When the Transmit FIFO is enabled (FIFOBYP is HIGH) and  
CE is sampled LOW by the rising edge of TXCLK, the output  
drivers for the TXFULL and TXEMPTY FIFO flags are  
enabled. When CE is sampled HIGH by the rising edge of  
TXCLK, these same output drivers are disabled.  
The data bus (TXDATA, RXDATA), command bus (TXCMD,  
RXCMD) and FIFO status flags (TXFULL, RXEMPTY, etc.) of  
each CY7C9689A on the shared bus can be connected  
together respectively. Each Slave can be assigned an  
address. The address of each Slave can be decoded by a  
decoder which drives the CE input of each Slave. The bus  
Master will poll each Slave by selecting (or Addressing) the  
device, and sample the FIFO flags. Depending on the FIFOs  
status on each Slave device, the Master can schedule read  
accesses to Slaves which have data in the RXFIFOs, and write  
When the Transmit FIFO is bypassed (FIFOBYP is LOW and  
not in byte-packed mode) and CE is sampled LOW by the  
rising edge of REFCLK, the output drivers for the TXFULL and  
TXEMPTY FIFO flags are enabled. When CE is sampled  
HIGH by the rising edge of REFCLK, the FIFO flag output  
drivers are disabled.  
Document #: 38-02020 Rev. *C  
Page 37 of 46  
CY7C9689A  
When CE is sampled LOW by the rising edge of RXCLK (input  
or output), the output drivers for the RXFULL and RXEMPTY  
FIFO flags are enabled. When CE is sampled HIGH by the  
rising edge of RXCLK, the FIFO flag output drivers are  
disabled.  
Transmit Data Selection  
Asynchronous With Shared Bus Timing and Control  
(Transmit FIFO Enabled)  
When CE is sampled LOW and TXRST is sampled HIGH by  
the rising edge of TXCLK, a Tx_Match condition is generated.  
This Tx_Match condition continues until CE is sampled HIGH  
or TXRST is sampled LOW at the rising edge of TXCLK. When  
a Tx_Match (or Tx_RstMatch) condition is present, the  
TXEMPTY and TXFULL output drivers are enabled. When a  
Tx_Match (or Tx_RstMatch) condition is not present, these  
same drivers are disabled (High-Z).  
Device Selection  
The concept of selection is used to control the access to the  
transmit and receive parallel-data ports of the device. There  
are three primary types of selection:  
Transmit data selection (with and without internal Transmit  
FIFO)  
Receive data selection (with and without internal Receive  
The selection state of the Transmit FIFO is entered when a  
Tx_Match condition is present, and TXEN transitions from  
HIGH to LOW. Once selected, the Transmit FIFO remains  
selected until TXEN is sampled HIGH by the rising edge of  
TXCLK. In the selected state, data present on the TXDATA  
inputs is captured and stored in the Transmit FIFO. This  
transmit interface selection process is shown in Figure 8.  
FIFO)  
Continuousselection(foreitherorbothtransmitandreceive  
interfaces).  
In addition to these normal selection types, there are two  
additional sequences that are used to control the internal  
Transmit and Receive FIFOs reset operations, and to control  
read/write access to the Serial Address Register:  
Synchronous With Shared Bus Timing and Control  
(Transmit FIFO Bypassed)  
Transmit reset sequence  
Receive reset sequence.  
When the Transmit FIFO is bypassed (FIFOBYP is LOW and  
not in byte-packed mode), the CY7C9689A must still be  
selected to write data into the Transmit Input Register.  
Of these operations, the transmit data selection and transmit  
reset sequence are mutually exclusive and cannot exist at the  
same time. The receive data selection and receive reset  
sequence are also mutually exclusive and cannot exist at the  
same time. Either transmit operation can exist at the same  
time as either receive operation.  
When CE is sampled LOW and TXRST is sampled HIGH by  
the rising edge of REFCLK, a Tx_Match condition is  
generated. This Tx_Match condition continues until CE is  
sampled HIGH or TXRST is sampled LOW at the rising edge  
of REFCLK. When a Tx_Match (or Tx_RstMatch) condition is  
present, the TXEMPTY and TXFULL output drivers are  
enabled (with the Transmit FIFO bypassed, the status flags  
normally indicate an Empty condition). When a Tx_Match (or  
Tx_RstMatch) condition is not present, these same drivers are  
disabled (High-Z).  
All normal forms of selection require that an Chip Enable must  
be asserted (CE sampled LOW) either at the same time as the  
selection control signal being sampled asserted, or one or  
more clock cycles prior to the selection control signal being  
sampled asserted.  
TXCLK  
TXRST  
CE  
[46]  
Tx_Match  
Note 47  
TXEN  
[46]  
Tx_Selected  
TXDATA/TXCMD  
D1  
D2  
D1  
D3  
D2  
(Shared Bus Timing)  
TXDATA/TXCMD  
D3  
(Cascade Timing)  
TXFULL  
Not Full  
Note 47  
Not Full  
Figure 8. Transmit Selection with Transmit FIFO Enabled  
Document #: 38-02020 Rev. *C  
Page 38 of 46  
CY7C9689A  
The selection state of the Transmit Input Register is entered  
when a Tx_Match condition is present, and TXEN transitions  
from HIGH to LOW. Once selected, the transmit input register  
remains selected until TXEN is sampled HIGH by the rising  
edge of REFCLK. In the selected state, data present on the  
TXDATA inputs is captured in the Transmit Input Register and  
passed to the Serializer or Encoder (as selected by the  
ENCBYP input). This transmit interface selection process is  
shown in Figure 9.  
Receive Data Selection  
Asynchronous With Shared Bus Timing and Control  
(Receive FIFO Enabled)  
When CE is sampled LOW and RXRST is sampled HIGH by  
the rising edge of RXCLK input, an Rx_Match condition is  
generated. This Rx_Match condition continues until CE is  
sampled HIGH or RXRST is sampled LOW at the rising edge  
of RXCLK input. When an Rx_Match (or Rx_RstMatch)  
condition is present, the RXEMPTY and RXFULL output  
drivers are enabled.  
When the 4B/5B Encoder is enabled and data is not written to  
the Transmit Input Register, the data stream is automatically  
padded with JK or LM SYNC characters. When the 4B/5B,  
5B/6B Encoder is disabled and no data is written to the  
Transmit Input Register, JK or LM SYNC characters are also  
automatically padded with SYNC characters.  
When an Rx_Match (or Rx_RstMatch) condition is not  
present, these same drivers are disabled (High-Z).  
The selection state of the Receive FIFO is entered when an  
Rx_Match condition is present, and RXEN transitions from  
HIGH to LOW. Once selected, the Receive FIFO remains  
selected until RXEN is sampled HIGH by the rising edge of  
RXCLK input. The selected state initiates a read cycle from the  
Receive FIFO and enables the Receive FIFO data onto the  
RXDATA bus. This receive interface selection process is  
shown in Figure 10.  
REFCLK  
TXRST  
CE  
[46]  
Tx_Match  
Note 47  
TXEN  
[46]  
Tx_Selected  
TXDATA/TXCMD  
D1  
D2  
D1  
D3  
D2  
(Shared Bus Timing)  
TXDATA/TXCMD  
D3  
(Cascade Timing)  
TXFULL  
Not Full  
Note 47  
Not Full  
Figure 9. Transmit Selection with Transmit FIFO Bypassed  
Notes:  
46. Signals labeled in italics are internal to the CY7C9689A.  
47. Signals shown as dotted lines represent the differences in timing and active state of signals when operated in Cascade Timing.  
Document #: 38-02020 Rev. *C  
Page 39 of 46  
CY7C9689A  
Synchronous With UTOPIA Timing and Control  
(Receive FIFO Bypassed)  
the Receive FIFO bypassed, these flags normally indicate a  
non-empty condition but may indicate empty if a JK or LM  
SYNC character is present in the output register and the  
receiver discard policy is non-0. When an Rx_Match (or  
Rx_RstMatch) condition is not present, these same drivers are  
disabled (High-Z).  
When the Receive FIFO is bypassed (FIFOBYP is LOW), the  
CY7C9689A must still be selected to enable the output drivers  
for the RXDATA bus. With the Receive FIFO bypassed,  
RXCLK becomes a synchronous output clock operating at the  
character rate.  
The selection state of the Receive Output Register is entered  
when an Rx_Match condition is present, and RXEN transitions  
from HIGH to LOW. Once selected, the Receive Output  
Register remains selected until RXEN is sampled HIGH by the  
rising edge of RXCLK output. In the selected state, the output  
drivers for the RXDATA outputs are enabled, and new data is  
presented to the RXDATA bus on every clock cycle.  
When CE is sampled LOW and RXRST is sampled HIGH by  
the rising edge of RXCLK output, an Rx_Match condition is  
generated. This Rx_Match condition continues until CE is  
sampled HIGH or RXRST is sampled LOW at the rising edge  
of RXCLK.  
When an Rx_Match (or Rx_RstMatch) condition is present,  
the RXEMPTY and RXFULL output drivers are enabled. With  
RXCLK  
RXRST  
CE  
[46]  
Rx_Match  
Note 47  
RXEN  
Rx_Selected  
[46]  
RXDATA/RXCMD  
RXEMPTY  
D1  
D2  
D3  
Not Empty  
Note 47  
Not Empty  
Figure 10. Receive Selection with Receive FIFO Enabled  
enabled (just as in a normal Tx_Match condition). When a  
Continuous Selection  
Tx_RstMatch (or Tx_Match) condition is not present, these  
same drivers are disabled (High-Z). The Transmit FIFO reset  
Address Match is shown in Figure 11. Note that although  
TXRST remains LOW for more than one clock cycle, the  
Tx_RstMatch does not because the CE signal is no longer  
asserted (LOW).  
Continuous Selection is a specialized form of selection which  
does not require sequenced assertion of CE and TXEN or  
RXEN to select the device for data transfers. In this  
Continuous Selection mode, the CE and associated TXEN or  
RXEN enable signal must be asserted when the device is  
powered up or during assertion of RESET. So long as these  
signals remain asserted, the device remains selected and data  
is accepted and presented on every clock cycle. Note: The  
use of continuous selection makes it impossible to reset the  
respective internal FIFOs, or to access the Serial Address  
Register.  
When CE and RXRST are both LOW, and this condition is  
sampled by the rising edge of RXCLK, an Rx_RstMatch  
condition is generated. This Rx_RstMatch condition continues  
until CE or RXRST is sampled HIGH, at the rising edge of  
RXCLK. When an Rx_RstMatch (or Rx_Match) condition is  
present, the RXEMPTY and RXFULL output drivers are  
enabled. When an Rx_RstMatch (or Rx_Match) condition is  
not present, these same drivers are disabled (High-Z). The  
Receive FIFO reset Address Match is shown in Figure 12.  
Note that while the FIFO flags remain asserted for more than  
one clock cycle, this is due to an Rx_Match condition, not a  
continuation of the Rx_RstMatch.  
FIFO Reset Address Match  
When CE and TXRST are both LOW, and this condition is  
sampled by the rising edge of TXCLK, a Tx_RstMatch  
condition is generated. This Tx_RstMatch condition continues  
until CE or TXRST is sampled HIGH by the rising edge of  
TXCLK. When a Tx_RstMatch (or Tx_Match) condition is  
present, the TXEMPTY and TXFULL output drivers are  
Document #: 38-02020 Rev. *C  
Page 40 of 46  
CY7C9689A  
Transmit FIFO Reset Sequence  
TXCLK  
TXRST  
The Transmit FIFO reset sequence (see Figure 15) is started  
when TXRST and CE are first sampled LOW by the rising edge  
of TXCLK. Because a Tx_RstMatch condition is present, the  
Transmit FIFO flags are asserted and can be used to track the  
status of any Transmit FIFO reset in progress. Once the reset  
sequence has reached its maximum count (eight TXCLK  
cycles), the Transmit FIFO flags are asserted to indicate a  
FULL condition (TXEMPTY is deasserted, and both TXHALF  
and TXFULL are asserted). This indicates that the Transmit  
FIFO reset has been recognized by the Transmit Control State  
Machine and that a reset has been started. However, if the  
TXEN is asserted prior to or during the assertion and sampling  
of TXRST, the reset sequence is inhibited until TXEN is  
removed. Note: The FIFO FULL state forced by the reset  
operation is different from a FULL state caused by normal  
FIFO data writes. For normal FIFO write operations, when  
FULL is first asserted, the Transmit FIFO must still accept up  
to four additional writes of data. When a FULL state is asserted  
due to a Transmit FIFO reset operation, the FIFO will not  
accept any additional data.  
CE  
[46]  
[46]  
Tx_RstMatch  
Tx_Match  
TXFULL  
Valid  
Figure 11. Transmit FIFO Reset Address Match  
RXCLK  
The Transmit FIFO reset does not complete until the external  
reset condition is removed. This can be removed by  
deassertion of either TXRST or CE. If CE is deasserted (HIGH)  
to remove the reset condition, the Transmit FIFO flags drivers  
are disabled, and the Transmit FIFO must be addressed at a  
later time to validate completion of the Transmit FIFO reset. If  
TXRST is deasserted (HIGH) to remove the reset condition,  
the Tx_RstMatch is changed to a Tx_Match, and the Transmit  
FIFO status flags remain driven. The Transmit FIFO reset  
operation is complete when the Transmit FIFO flags indicate  
an EMPTY state (TXEMPTY is asserted and both TXHALF  
and TXFULL are deasserted). A valid Transmit FIFO reset  
sequence is shown in Figure 15.  
RXRST  
CE  
[46]  
Rx_RstMatch  
[46]  
Rx_Match  
RXEMPTY  
Valid Valid  
Figure 12. Receive FIFO Reset Address Match  
Here the TXRST and CE are asserted (LOW) at the same  
time. When these signals are both sampled LOW by TXCLK,  
a Tx_RstMatch condition is present. With TXEN deasserted  
(HIGH), the Transmit FIFO is not selected for data transfers.  
This Tx_RstMatch condition must remain for eight TXCLK  
cycles to initiate the Tx_FIFO_Reset. Following this the  
TXFULL FIFO status flag is asserted to indicate that the  
Transmit FIFO reset sequence has completed and that a  
Transmit FIFO reset is in progress.  
FIFO Reset Sequence  
On power-up, the Transmitter and Receiver FIFOs are cleared  
automatically. If the usage of the FIFOs in specific operating  
modes results in stale or unwanted data, this data can be  
cleared by resetting the respective FIFO. Data in the Transmit  
FIFO will empty automatically if it is enabled to read the FIFO  
(assuming TXHALT is not LOW). Stale received data can be  
flushedby reading it, or the Receive FIFO can be reset to  
remove the unwanted data.  
When the TXRST signal is deasserted (HIGH), CE remains  
LOW to allow the FIFO status flags to be driven. This allows  
the completion of the reset operation to be monitored. To allow  
better multi-tasking on multi-PHY implementations, it is  
possible to deassert CE (HIGH) as soon as the FULL state is  
indicated. The FIFO reset operation will complete and the  
EMPTY state (indicating completion of the reset operation)  
can be detected during a separate polling operation.  
The Transmit and Receive FIFOs are reset when the  
Tx_RstMatch or Rx_RstMatch condition remains present for  
eight consecutive clock cycles. Any disruption of the reset  
sequence prior to reaching the eight cycle count, either by  
removal of CE or the respective TXRST or RXRST, or  
assertion of the associated TXEN or RXEN, terminates the  
sequence and does not reset the FIFO. Because CE must  
remain asserted during the reset sequence, the addressed  
FIFO flags remain driven during the entire sequence.  
For those links implemented with a single PHY, it is possible  
to hardwire CE LOW and still perform normal accesses and  
reset operations. This is shown in Figure 13. In a single-PHY  
implementation, a Transmit FIFO reset can never be initiated  
with TXEN asserted at the same time as TXRST. Since CE is  
always LOW, any assertion of TXEN causes the Transmit  
FIFO to be selected, clearing the reset counter.  
Document #: 38-02020 Rev. *C  
Page 41 of 46  
CY7C9689A  
TXCLK  
TXRST  
Note 48  
TXEN  
CE  
Tx_RstMatch[49]  
[49]  
Tx_Match  
Tx_FIFO_Reset[49]  
TXFULL  
Note 48  
Not Full  
Full  
Figure 13. Transmit FIFO Reset Sequence with Constant CE  
TXCLK  
TXRST  
TXEN  
CE  
Note 48  
[49]  
Tx_RstMatch  
Tx_Match[49]  
Tx_FIFO_Reset[49]  
TXFULL  
Note 48  
Not Full  
Figure 14. Invalid Transmit FIFO Reset Sequence with TXEN Asserted  
Notes:  
48. Signals shown as dotted lines indicate timing and levels when configured for external FIFOs (EXTFIFO is HIGH).  
49. Signal names listed in italics are internal signals, shown for reference only.  
Document #: 38-02020 Rev. *C  
Page 42 of 46  
CY7C9689A  
TXCLK  
TXRST  
TXEN  
CE  
Note 48  
Tx_RstMatch[49]  
Tx_Match[49]  
[49]  
Tx_FIFO_Reset  
TXFULL  
Note 48  
Not Full  
Full  
Figure 15. Transmit FIFO Reset Sequence  
Figure 14 shows a sequence of input signals which will not  
produce a FIFO reset. In this case TXEN was asserted to  
select a Transmit FIFO for data transfers. Because TXEN  
remains active, the assertion of CE and TXRST does not  
initiate a reset operation. This is shown by the TXFULL flag  
remaining HIGH (deasserted) following what would be the  
normal expiration of the seven-state reset counter.  
selection of the interface. A sample Receive FIFO reset  
sequence is shown in Figure 16. Upon recognition of a  
Receive FIFO reset, the Receive FIFO flags are forced to  
indicate an EMPTY state to prohibit additional reads from the  
FIFO. Unlike the Transmit FIFO, where the internal completion  
of the reset operation is shown by first going FULL and later  
going EMPTY when the internal reset is complete, there is no  
secondary indication of the completion of the internal reset of  
the Receive FIFO. The Receive FIFO is usable as soon as  
new data is placed into it by the Receive Control State  
Machine.  
Receive FIFO Reset Sequence  
The Receive FIFO reset sequence operates (for the most part)  
the same as the Transmit FIFO reset sequence. The same  
requirements exist for the assertion state of RXRST and  
RXCLK  
RXRST  
RXEN  
CE  
Note 48  
Rx_RstMatch[49]  
Rx_Match[49]  
Rx_FIFO_Reset [49]  
RXEMPTY  
Note 48  
Empty  
Not Empty  
Figure 16. Receive FIFO Reset Sequence  
Document #: 38-02020 Rev. *C  
Page 43 of 46  
CY7C9689A  
Printed Circuit Board Layout Suggestions  
OUTA±  
OUTB±  
INA±  
INB±  
Power Supply Bypass  
0.01-µF MLC X7R  
1206 Chip Cap (4 sites)  
Power Supply Bypass  
0.01-µF MLC X7R  
CURSETB  
Resistor  
CURSETA  
Resistor  
Power Supply Bypass  
0.01-µF MLC X7R  
1206 Chip Cap (2 sites)  
RXSC/D  
REFCLK  
CY7C9689A-AC  
Power Supply Bypass  
0.01-µF MLC X7R  
RESET  
Power Supply Bypass  
0.01-µF MLC X7R  
Via to VDD plane  
Via to VSS plane  
This is a typical printed circuit board layout showing example  
placement of power supply bypass components and other  
components mounted on the same side as the CY7C9689A.  
Other layouts, including cases with components mounted on  
the reverse side would work as well.  
Ordering Information  
Ordering Code  
CY7C9689A-AC  
CY7C9689A-AI  
Package Name  
A100  
Package Type  
Operating Range  
Commercial  
Industrial  
100-lead Thin Quad Flat Pack  
100-lead Thin Quad Flat Pack  
A100  
Document #: 38-02020 Rev. *C  
Page 44 of 46  
CY7C9689A  
Package Diagram  
100-pin Thin Plastic Quad Flat Pack (TQFP) A100  
51-85048-B  
HOTLink is a registered trademark of Cypress Semiconductor, Inc. AMD, TAXI, and TAXIchip are trademarks of Advanced Micro  
Devices. Inc. All product and company names mentioned in this document are trademarks of their respective holders.  
Document #: 38-02020 Rev. *C  
Page 45 of 46  
© Cypress Semiconductor Corporation, 2002. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use  
of any circuitry other than circuitry embodied in a Cypress Semiconductor product. Nor does it convey or imply any license under patent or other rights. Cypress Semiconductor does not authorize  
its products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress  
Semiconductor products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress Semiconductor against all charges.  
CY7C9689A  
Document Title: CY7C9689A TAXI-compatible HOTLink Transceiver  
Document Number: 38-02020  
Issue  
Date  
Orig. of  
Change  
REV.  
**  
ECN NO.  
106249  
107695  
113563  
Description of Change  
Change from Spec number: 38-00758 to 38-02020  
Changed part number: CY7C9689 to CY7C9689A  
04/20/01  
06/28/01  
04/10/02  
SZV  
SPN  
REV  
*A  
*B  
Removed parity reference  
Deleted mention of Byte-packer  
Fixed formatting to change mF to µF  
*C  
118318  
11/08/02  
REV  
Changed pins 23 and 29 to RXDATA[11:10]/RXCMD[1:0]  
LFI was changed from three stateto just output pin  
Fixed flip flop to Q as output and D as input  
Font problem with up-arrow symbols corrected  
Document #: 38-02020 Rev. *C  
Page 46 of 46  

相关型号:

CY7C9689A-AC

TAXI-compatible HOTLink Transceiver
CYPRESS

CY7C9689A-AI

TAXI-compatible HOTLink Transceiver
CYPRESS

CY7C9689A-AXC

TAXI⑩-compatible HOTLink㈢ Transceiver
CYPRESS

CY7C9689A-AXI

TAXI⑩-compatible HOTLink㈢ Transceiver
CYPRESS

CY7C9689A_06

TAXI⑩-compatible HOTLink㈢ Transceiver
CYPRESS

CY7C9689A_11

TAXI™-compatible HOTLink Transceiver
CYPRESS

CY7C9700

LAN Controller, 12.5MBps, CMOS, PQFP208, PLASTIC, QFP-208
CYPRESS

CY7C971

LAN Transceiver
ETC

CY7C971-NC

Ethernet Transceiver, PQFP80, PLASTIC, QFP-80
CYPRESS

CY7C9745

Network Interface, CMOS, PQFP208,
CYPRESS

CY7C9745-NC

LAN Controller, 6 Channel(s), 1.25MBps, CMOS, PQFP208, PLASTIC, QFP-208
CYPRESS

CY7C9915

3.3V Programmable Skew Clock Buffer
CYPRESS