Programmable Skew Clock Buffer (PSCB)  
tions. This multiple-output clock driver provides the system in-  
tegrator with functions necessary to optimize the timing of  
Features  
• All output pair skew <100 ps typical (250 max.)  
• 3.75- to 100-MHz output operation  
• User-selectable output functions  
— Selectable skew to 18 ns  
high-performance computer systems. Eight individual TTL  
drivers, arranged as four pairs of user-controllable outputs,  
can each drive terminated transmission lines with impedances  
as low as 50while delivering minimal and specified output skews  
and full-swing logic levels.  
— Inverted and non-inverted  
Each output can be hardwired to one of nine delay or function  
configurations. Delay increments of 0.6 to 1.5 ns are deter-  
mined by the operating frequency with outputs able to skew up  
to ±6 time units from their nominal zeroskew position. The com-  
pletely integrated PLL allows external load and transmission line  
delay effects to be canceled. When this zero delaycapability of the  
PSCB is combined with the selectable output skew functions, the  
user can create output-to-output delays of up to ±12 time units.  
— Operation at ½ and ¼ input frequency  
— Operation at 2x and 4x input frequency (input as low  
as 3.75 MHz)  
• Zero input to output delay  
• 50% duty-cycle outputs  
Outputs drive 50terminated lines  
Low operating current  
32-pin PLCC/LCC package  
Divide-by-two and divide-by-four output functions are provided  
for additional flexibility in designing complex clock systems.  
When combined with the internal PLL, these divide functions  
allow distribution of a low-frequency clock that can be multi-  
plied by two or four at the clock destination. This facility mini-  
mizes clock distribution difficulty while allowing maximum sys-  
tem clock speed and flexibility.  
Jitter < 200 ps peak-to-peak (< 25 ps RMS)  
Compatible with a Pentium-based processor  
Functional Description  
The CY7B9911 High Speed Programmable Skew Clock Buffer  
(PSCB) offers user-selectable control over system clock func-  
Logic Block Diagram  
Pin Configuration  
TEST  
PLCC/LCC  
PHASE  
FREQ  
DET  
FB  
VCO AND  
TIME UNIT  
GENERATOR  
FILTER  
REF  
4
3
2
1
32 31 30  
29  
FS  
2F0  
GND  
1F1  
1F0  
5
6
3F1  
4F0  
28  
27  
4Q0  
4Q1  
4F0  
4F1  
4F1  
7
8
9
SELECT  
INPUTS  
(THREE  
LEVEL)  
V
26  
25  
24  
23  
CCQ  
CY7B9911  
V
CCN  
SKEW  
SELECT  
MATRIX  
V
CCN  
3Q0  
3Q1  
3F0  
3F1  
4Q1  
10  
1Q0  
1Q1  
GND  
GND  
4Q0  
GND  
GND  
11  
12  
22  
21  
2Q0  
2Q1  
2F0  
2F1  
13  
14 15 16 17 18 19 20  
1Q0  
1Q1  
1F0  
1F1  
7B99112  
7B99111  
Pentium is a trademark of Intel Corporation.  
Cypress Semiconductor Corporation  
3901 North First Street  
San Jose  
CA 95134  
408-943-2600  
Document #: 38-07209 Rev. **  
Revised September 26, 2001  
CY7B9911  
RoboClock+  
Pin Definitions  
Signal  
Name  
I/O  
Description  
REF  
I
Reference frequency input. This inputsupplies the frequency and timingagainst whichallfunctional  
variation is measured.  
FB  
I
PLL feedback input (typically connected to one of the eight outputs).  
Three-level frequency range select. See Table 1.  
Three-level function select inputs for output pair 1 (1Q0, 1Q1). See Table 2.  
Three-level function select inputs for output pair 2 (2Q0, 2Q1). See Table 2  
Three-level function select inputs for output pair 3 (3Q0, 3Q1). See Table 2  
Three-level function select inputs for output pair 4 (4Q0, 4Q1). See Table 2  
Three-level select. See test mode section under the block diagram descriptions.  
Output pair 1. See Table 2.  
FS  
I
1F0, 1F1  
2F0, 2F1  
3F0, 3F1  
4F0, 4F1  
TEST  
I
I
I
I
I
1Q0, 1Q1  
2Q0, 2Q1  
3Q0, 3Q1  
4Q0, 4Q1  
VCCN  
O
O
Output pair 2. See Table 2.  
O
Output pair 3. See Table 2.  
O
Output pair 4. See Table 2.  
PWR  
PWR  
PWR  
Power supply for output drivers.  
VCCQ  
Power supply for internal circuitry.  
GND  
Ground.  
(xF0, xF1) inputs. Table 2 below shows the nine possible out-  
Block Diagram Description  
put functions for each section as determined by the function  
select inputs. All times are measured with respect to the REF  
input assuming that the output connected to the FB input has  
0tU selected.  
Phase Frequency Detector and Filter  
These two blocks accept inputs from the reference frequency  
(REF) input and the feedback (FB) input and generate correc-  
tion information to control the frequency of the Voltage-Con-  
trolled Oscillator (VCO). These blocks, along with the VCO,  
form a Phase-Locked Loop (PLL) that tracks the incoming  
REF signal.  
Table 2. Programmable Skew Configurations[1]  
Function Selects  
Output Functions  
1F1, 2F1, 1F0, 2F0, 1Q0,1Q1,  
3F1, 4F1 3F0, 4F0 2Q0, 2Q1 3Q0, 3Q1 4Q0, 4Q1  
VCO and Time Unit Generator  
LOW  
LOW  
LOW  
MID  
LOW  
MID  
4tU  
3tU  
2tU  
1tU  
0tU  
Divide by 2 Divide by 2  
The VCO accepts analog control inputs from the PLL filter  
block and generates a frequency that is used by the time unit  
generator to create discrete time units that are selected in the  
skew select matrix. The operational range of the VCO is de-  
termined by the FS control pin. The time unit (tU) is determined  
by the operating frequency of the device and the level of the  
FS pin as shown in Table 1.  
6tU  
4tU  
2tU  
0tU  
6tU  
4tU  
2tU  
0tU  
HIGH  
LOW  
MID  
MID  
MID  
HIGH  
LOW  
MID  
+1tU  
+2tU  
+3tU  
+4tU  
+2tU  
+4tU  
+6tU  
+2tU  
+4tU  
+6tU  
Table 1. Frequency Range Select and tU Calculation[1]  
HIGH  
HIGH  
fNOM (MHz)  
1
= -----------------------  
Approximate  
Frequency(MHz)At  
Which tU = 1.0 ns  
U
HIGH  
HIGH  
Divide by 4 Inverted  
f
NOM × N  
FS[2, 3] Min. Max.  
where N =  
Notes:  
1. For all three-state inputs, HIGH indicates a connection to VCC, LOW  
indicates a connection to GND, and MID indicates an open connection.  
Internal termination circuitry holds an unconnected input to VCC/2.  
2. The level to be set on FS is determined by the normaloperating fre-  
quency (fNOM) of the VCO and Time Unit Generator (see Logic Block  
Diagram). Nominal frequency (fNOM) always appears at 1Q0 and the  
other outputs when they are operated in their undivided modes (see  
Table 2). The frequency appearing at the REF and FB inputs will be fNOM  
when the output connected to FB is undivided. The frequency of the REF  
and FB inputs will be fNOM/2 or fNOM/4 when the part is configured for a  
frequency multiplication by using a divided output as the FB input.  
3. When the FS pin is selected HIGH, the REF input must not transition  
upon power-up until VCC has reached 4.3V.  
LOW  
MID  
15  
25  
40  
30  
50  
44  
26  
16  
22.7  
38.5  
62.5  
HIGH  
100  
Skew Select Matrix  
The skew select matrix is comprised of four independent sec-  
tions. Each section has two low-skew, high-fanout drivers  
(xQ0, xQ1), and two corresponding three-level function select  
Document #: 38-07209 Rev. **  
Page 2 of 12  
CY7B9911  
RoboClock+  
FB Input  
REF Input  
1Fx  
2Fx  
3Fx  
4Fx  
(N/A)  
LM  
6t  
4t  
3t  
U
U
U
LL  
LH  
LM  
(N/A)  
LH  
ML  
ML  
2t  
1t  
U
U
(N/A)  
MM  
MH  
HL  
MM  
(N/A)  
MH  
0t  
U
U
U
U
+1t  
+2t  
+3t  
HM  
(N/A)  
HH  
HL  
HM  
+4t  
+6t  
U
U
(N/A)  
(N/A)  
(N/A)  
LL/HH  
HH  
DIVIDED  
INVERT  
7B99113  
Figure 1. Typical Outputs with FB Connected to a Zero-Skew Output[4]  
Test Mode  
Maximum Ratings  
The TEST input is a three-level input. In normal system oper-  
ation, this pin is connected to ground, allowing the CY7B9911  
to operate as explained briefly above (for testing purposes,  
any of the three-level inputs can have a removable jumper to  
ground, or be tied LOW through a 100resistor. This will allow  
an external tester to change the state of these pins.)  
(Above which the useful life may be impaired. For user guide-  
lines, not tested.)  
Storage Temperature ................................. 65°C to +150°C  
Ambient Temperature with  
Power Applied ............................................ 55°C to +125°C  
Supply Voltage to Ground Potential ...............0.5V to +7.0V  
DC Input Voltage ............................................0.5V to +7.0V  
Output Current into Outputs (LOW)............................. 64 mA  
If the TEST input is forced to its MID or HIGH state, the device  
will operate with its internal phase locked loop disconnected,  
and input levels supplied to REF will directly control all outputs.  
Relative output to output functions are the same as in normal  
mode.  
Static Discharge Voltage ........................................... >2001V  
(per MIL-STD-883, Method 3015)  
In contrast with normal operation (TEST tied LOW). All outputs  
will function based only on the connection of their own function  
select inputs (xF0 and xF1) and the waveform characteristics  
of the REF input.  
Latch-Up Current..................................................... >200 mA  
Operating Range  
Ambient  
Temperature  
Range  
VCC  
Commercial  
0°C to +70°C  
5V ± 10%  
Note:  
4. FB connected to an output selected for zeroskew (i.e., xF1 = xF0 =  
MID).  
Document #: 38-07209 Rev. **  
Page 3 of 12  
CY7B9911  
RoboClock+  
Electrical Characteristics Over the Operating Range  
CY7B9911  
Parameter  
Description  
Output HIGH Voltage  
Test Conditions  
VCC = Min., IOH = 16 mA  
VCC = Min., IOH =40 mA  
VCC = Min., IOL = 46 mA  
VCC = Min., IOL = 46 mA  
Min.  
Max.  
Unit  
VOH  
2.4  
V
VOL  
Output LOW Voltage  
0.45  
V
VIH  
VIL  
Input HIGH Voltage  
(REF and FB inputs only)  
2.0  
VCC  
0.8  
V
V
Input LOW Voltage  
(REF and FB inputs only)  
0.5  
VIHH  
VIMM  
VILL  
IIH  
Three-Level Input HIGH  
Voltage (Test, FS, xFn)[5]  
Min. VCC Max.  
Min. VCC Max.  
Min. VCC Max.  
VCC 0.85  
VCC  
V
Three-Level Input MID  
VCC/2 500 mV VCC/2 + 500 mV  
V
Voltage (Test, FS, xFn)[5]  
Three-Level Input LOW  
Voltage (Test, FS, xFn)[5]  
0.0  
500  
50  
0.85  
10  
V
Input HIGH Leakage Current (REF and VCC = Max., VIN = Max.  
FB inputs only)  
µA  
µA  
µA  
µA  
µA  
mA  
mA  
IIL  
Input LOW Leakage Current (REF and VCC = Max., VIN = 0.4V  
FB inputs only)  
IIHH  
IIMM  
IILL  
Input HIGH Current  
(Test, FS, xFn)  
VIN = VCC  
VIN = VCC/2  
VIN = GND  
200  
50  
Input MID Current  
(Test, FS, xFn)  
Input LOW Current  
(Test, FS, xFn)  
200  
250  
85  
IOS  
Output Short Circuit  
Current[6]  
VCC = Max., VOUT  
= GND (25°C only)  
ICCQ  
Operating Current Used by  
Internal Circuitry  
VCCN = VCCQ  
Max., All Input  
Selects Open  
=
Coml  
ICCN  
Output Buffer Current per  
Output Pair[7]  
VCCN = VCCQ = Max.,  
IOUT = 0 mA  
Input Selects Open, fMAX  
14  
78  
mA  
PD  
Power Dissipation per  
Output Pair[8]  
VCCN = VCCQ = Max.,  
IOUT = 0 mA  
mW  
Input Selects Open, fMAX  
Notes:  
5. These inputs are normally wired to VCC, GND, or left unconnected (actual threshold voltages vary as a percentage of VCC). Internal termination resistors hold  
unconnected inputs at VCC/2. If these inputs are switched, the function and timing of the outputs may glitch and the PLL may require an additional tLOCK time  
before all datasheet limits are achieved.  
6. CY7B9911 should be tested one output at a time, output shorted for less than one second, less than 10% duty cycle. Room temperature only.  
7. Total output current per output pair can be approximated by the following expression that includes device current plus load current:  
CY7B9911: ICCN = [(4 + 0.11F) + [((835 3F)/Z) + (.0022FC)]N] x 1.1  
Where  
F = frequency in MHz  
C = capacitive load in pF  
Z = line impedance in ohms  
N = number of loaded outputs; 0, 1, or 2  
FC = F  
C
8. Total power dissipation per output pair can be approximated by the following expression that includes device power dissipation plus power dissipation due to  
the load circuit:  
CY7B9911: PD = [(22 + 0.61F) + [((1550 2.7F)/Z) + (.0125FC)]N] x 1.1  
See note 7 for variable definition.  
Document #: 38-07209 Rev. **  
Page 4 of 12  
CY7B9911  
RoboClock+  
Capacitance[9]  
Parameter  
Description  
Test Conditions  
Max.  
Unit  
CIN  
Input Capacitance  
TA = 25°C, f = 1 MHz, VCC = 5.0V  
10  
pF  
Note:  
9. Applies to REF and FB inputs only. Tested initially and after any design or process changes that may affect these parameters.  
AC Test Loads and Waveforms  
5V  
3.0V  
2.0V  
=1.5V  
0.8V  
2.0V  
th  
0.8V  
R1=130  
R2=91  
R1  
R2  
V
th  
V =1.5V  
C = 30 pF  
L
0.0V  
C
(Includes fixture and probe capacitance)  
L
1ns  
1ns  
7B99114  
7B99115  
TTL ACTest Load (CY7B9911)  
TTL Input Test Waveform (CY7B9911)  
Document #: 38-07209 Rev. **  
Page 5 of 12  
CY7B9911  
RoboClock+  
Switching Characteristics Over the Operating Range[2, 10, 11]  
CY7B99115  
CY7B99117  
Parameter  
Description  
Min.  
Typ.  
Max.  
30  
Min.  
15  
Typ.  
Max.  
30  
Unit  
fNOM  
Operating Clock  
FS = LOW[1, 2]  
FS = MID[1, 2]  
15  
25  
MHz  
Frequency in MHz  
50  
25  
50  
FS = HIGH[1, 2 , 3]  
40  
100  
40  
100  
tRPWH  
tRPWL  
tU  
REF Pulse Width HIGH  
REF Pulse Width LOW  
Programmable Skew Unit  
4.0  
4.0  
4.0  
4.0  
ns  
ns  
See  
Table 1  
See  
Table 1  
tSKEWPR  
Zero Output Matched-Pair Skew  
(XQ0, XQ1)[12, 13]  
0.1  
0.25  
0.1  
0.25  
ns  
tSKEW0  
tSKEW1  
Zero Output Skew (All Outputs)[12, 14]  
0.25  
0.6  
0.5  
0.7  
0.3  
0.6  
0.75  
1.0  
ns  
ns  
Output Skew (Rise-Rise, Fall-Fall, Same  
Class Outputs)[12, 15]  
tSKEW2  
tSKEW3  
tSKEW4  
Output Skew (Rise-Fall, Nominal-Inverted,  
Divided-Divided)[12, 15]  
0.5  
0.5  
0.5  
1.2  
0.9  
1.2  
1.0  
0.7  
1.2  
1.7  
1.4  
1.9  
ns  
ns  
ns  
Output Skew (Rise-Rise, Fall-Fall, Different  
Class Outputs)[12, 15]  
Output Skew (Rise-Fall, Nominal-Divided,  
Divided-Inverted)[12, 15]  
tDEV  
Device-to-Device Skew[11, 16]  
Propagation Delay, REF Rise to FB Rise  
Output Duty Cycle Variation[17]  
Output HIGH Time Deviation from 50%[18, 19]  
Output LOW Time Deviation from 50%[18, 19]  
Output Rise Time[18, 20]  
1.25  
+0.5  
+1.0  
2.0  
1.65  
+0.7  
+1.2  
2.5  
3
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ms  
ps  
ps  
tPD  
0.5  
1.0  
0.0  
0.0  
0.7  
1.2  
0.0  
0.0  
tODCV  
tPWH  
tPWL  
tORISE  
tOFALL  
tLOCK  
tJR  
2.5  
0.15  
0.15  
1.0  
1.0  
1.5  
0.15  
0.15  
1.5  
1.5  
2.5  
2.5  
0.5  
25  
Output Fall Time[18, 20]  
1.5  
PLL Lock Time[21]  
0.5  
Cycle-to-Cycle Output  
Jitter  
RMS[11]  
25  
Peak-to-Peak[11]  
200  
200  
Notes:  
10. Test measurement levels for the CY7B9911 are TTL levels (1.5V to 1.5V).  
Test conditions assume signal transition times of 2 ns or less and output loading  
as shown in the AC Test Loads and Waveforms unless otherwise specified.  
11. Guaranteed by statistical correlation. Tested initially and after any design  
or process changes that may affect these parameters.  
12. SKEW is defined as the time between the earliest and the latest output  
transition among all outputs for which the same tU delay has been selected  
when all are loaded with 30 pF and terminated with 50to 2.06V.  
16. tDEV is the output-to-output skew between any two devices operating under the  
same conditions (VCC ambient temperature, air flow, etc.)  
17.  
tODCV is the deviation of the output from a 50% duty cycle. Output pulse width  
variations are included in tSKEW2 and tSKEW4 specifications.  
18. Specified with outputs loaded with 30 pF. Devices are terminated through  
50to 2.06V.  
19. tPWH is measured at 2.0V. tPWL is measured at 0.8V.  
20. tORISE and tOFALL measured between 0.8V and 2.0V.  
13.  
t
SKEWPR is defined as the skew between a pair of outputs (XQ0 and XQ1) when  
21. tLOCK is the time that is required before synchronization is achieved. This speci-  
all eight outputs are selected for 0tU.  
fication is valid only after VCC is stable and within normal operating limits. This  
parameter is measured from the application of a new signal or frequency at REF  
or FB until tPD is within specified limits.  
14. tSKEW0 is defined as the skew between outputs when they are selected for 0tU.  
Other outputs are divided or inverted but not shifted.  
15. There are three classes of outputs: Nominal (multiple of tU delay), Inverted  
(4Q0 and 4Q1 only with 4F0 = 4F1 = HIGH), and Divided (3Qx and 4Qx only in  
Divide-by-2 or Divide-by-4 mode).  
Document #: 38-07209 Rev. **  
Page 6 of 12  
CY7B9911  
RoboClock+  
AC Timing Diagrams  
t
t
RPWL  
REF  
t
RPWH  
REF  
t
t
ODCV  
PD  
t
ODCV  
FB  
Q
t
JR  
t
t
t
t
SKEWPR,  
SKEW0,1  
SKEWPR,  
SKEW0,1  
OTHERQ  
t
SKEW2  
t
SKEW2  
INVERTED Q  
t
SKEW3,4  
t
t
SKEW3,4  
t
SKEW3,4  
REF DIVIDED BY 2  
REF DIVIDED BY 4  
t
SKEW1,3, 4  
SKEW2,4  
7B99118  
Document #: 38-07209 Rev. **  
Page 7 of 12  
CY7B9911  
RoboClock+  
Operational Mode Descriptions  
REF  
LOAD  
Z
Z
0
L1  
L2  
FB  
SYSTEM  
CLOCK  
REF  
FS  
LOAD  
LOAD  
4Q0  
4Q1  
4F0  
4F1  
0
3Q0  
3Q1  
3F0  
3F1  
L3  
L4  
2F0  
2F1  
2Q0  
2Q1  
Z
0
1F0  
1F1  
1Q0  
1Q1  
LOAD  
TEST  
Z
0
LENGTH L1 = L2 = L3 = L4  
7B99119  
Figure 2. Zero-Skew and/or Zero-Delay Clock Driver  
Figure 2 shows the PSCB configured as a zero-skew clock  
buffer. In this mode the 7B9911 can be used as the basis for a  
low-skew clock distribution tree. When all of the function select  
inputs (xF0, xF1) are left open, the outputs are aligned and  
may each drive a terminated transmission line to an indepen-  
dent load. The FB input can be tied to any output in this con-  
figuration and the operating frequency range is selected with  
the FS pin. The low-skew specification, coupled with the ability  
to drive terminated transmission lines (with impedances as low  
as 50 ohms), allows efficient printed circuit board design.  
REF  
LOAD  
Z
0
L1  
L2  
FB  
REF  
FS  
SYS–  
TEM  
CLOCK  
LOAD  
LOAD  
4Q0  
4Q1  
4F0  
4F1  
Z
0
3Q0  
3Q1  
3F0  
3F1  
L3  
L4  
2F0  
2F1  
2Q0  
2Q1  
Z
0
1F0  
1F1  
1Q0  
1Q1  
LOAD  
TEST  
Z
0
LENGTH L1 = L2  
L3 < L2 by 6 inches  
L4 > L2 by 6 inches  
7B991110  
Figure 3. Programmable-Skew Clock Driver  
Figure 3 shows a configuration to equalize skew between met-  
al traces of different lengths. In addition to low skew between  
outputs, the PSCB can be programmed to stagger the timing  
of its outputs. The four groups of output pairs can each be  
programmed to different output timing. Skew timing can be  
adjusted over a wide range in small increments with the appro-  
priate strapping of the function select pins. In this configuration  
the 4Q0 output is fed back to FB and configured for zero skew.  
The other three pairs of outputs are programmed to yield dif-  
ferent skews relative to the feedback. By advancing the clock  
signal on the longer traces or retarding the clock signal on  
shorter traces, all loads can receive the clock pulse at the  
same time.  
In this illustration the FB input is connected to an output with  
0-ns skew (xF1, xF0 = MID) selected. The internal PLL syn-  
chronizes the FB and REF inputs and aligns their rising edges  
to insure that all outputs have precise phase alignment.  
Clock skews can be advanced by ±6 time units (tU) when using  
an output selected for zero skew as the feedback. A wider range of  
delays is possible if the output connected to FB is also skewed.  
Since Zero Skew, +tU, and tU are defined relative to output  
groups, and since the PLL aligns the rising edges of REF and FB,  
it is possible to create wider output skews by proper selection of the  
xFn inputs. For example a +10 tU between REF and 3Qx can be  
achieved by connecting 1Q0 to FB and setting 1F0 = 1F1 = GND,  
3F0 = MID, and 3F1 = High. (Since FB aligns at 4 tU and 3Qx  
Document #: 38-07209 Rev. **  
Page 8 of 12  
CY7B9911  
RoboClock+  
skews to +6 tU, a total of +10 tU skew is realized.) Many other con-  
figurations can be realized by skewing both the output used as the  
FB input and skewing the other outputs.  
simultaneously and are out of phase on their rising edge. This  
will allow the designer to use the rising edges of the 12 fre-  
1
quency and  
frequency outputs without concern for ris-  
4
ing-edge skew. The 2Q0, 2Q1, 1Q0, and 1Q1 outputs run at  
80 MHz and are skewed by programming their select inputs  
accordingly. Note that the FS pin is wired for 80-MHz operation  
because that is the frequency of the fastest output.  
REF  
FB  
REF  
REF  
FS  
4Q0  
4F0  
4F1  
FB  
REF  
20 MHz  
4Q1  
FS  
3Q0  
3Q1  
3F0  
3F1  
10 MHz  
4Q0  
4F0  
4Q1  
4F1  
2Q0  
2Q1  
2F0  
2F1  
5 MHz  
3Q0  
3Q1  
3F0  
3F1  
1Q0  
1Q1  
1F0  
1F1  
20 MHz  
2Q0  
2Q1  
2F0  
2F1  
TEST  
1F0  
1F1  
1Q0  
1Q1  
7B991111  
Figure 4. Inverted Output Connections  
TEST  
7B991113  
Figure 4 shows an example of the invert function of the PSCB.  
In this example the 4Q0 output used as the FB input is pro-  
grammed for invert (4F0 = 4F1 = HIGH) while the other three  
pairs of outputs are programmed for zero skew. When 4F0 and  
4F1 are tied high, 4Q0 and 4Q1 become inverted zero phase  
outputs. The PLL aligns the rising edge of the FB input with the  
rising edge of the REF. This causes the 1Q, 2Q, and 3Q out-  
puts to become the invertedoutputs with respect to the REF  
input. By selecting which output is connect to FB, it is possible  
to have 2 inverted and 6 non-inverted outputs or 6 inverted and  
2 non-inverted outputs. The correct configuration would be de-  
termined by the need for more (or fewer) inverted outputs. 1Q,  
2Q, and 3Q outputs can also be skewed to compensate for  
varying trace delays independent of inversion on 4Q.  
Figure 6. Frequency Divider Connections  
Figure 6 demonstrates the PSCB in a clock divider application.  
2Q0 is fed back to the FB input and programmed for zero skew.  
3Qx is programmed to divide by four. 4Qx is programmed to  
divide by two. Note that the falling edges of the 4Qx and 3Qx  
outputs are aligned. This allows use of the rising edges of the  
12 frequency and 14 frequency without concern for skew mis-  
match. The 1Qx outputs are programmed to zero skew and  
are aligned with the 2Qx outputs. In this example, the FS input  
is grounded to configure the device in the 15- to 30-MHz range  
since the highest frequency output is running at 20 MHz.  
Figure 7 shows some of the functions that are selectable on  
the 3Qx and 4Qx outputs. These include inverted outputs and  
outputs that offer divide-by-2 and divide-by-4 timing. An invert-  
ed output allows the system designer to clock different sub-  
systems on opposite edges, without suffering from the pulse  
asymmetry typical of non-ideal loading. This function allows  
the two subsystems to each be clocked 180 degrees out of  
phase, but still to be aligned within the skew spec.  
REF  
FB  
20 MHz  
REF  
FS  
40 MHz  
4Q0  
4Q1  
The divided outputs offer a zero-delay divider for portions of  
the system that need the clock to be divided by either two or  
four, and still remain within a narrow skew of the 1Xclock.  
Without this feature, an external divider would need to be add-  
ed, and the propagation delay of the divider would add to the  
skew between the different clock signals.  
4F0  
4F1  
20 MHz  
80 MHz  
3Q0  
3Q1  
3F0  
3F1  
2F0  
2F1  
2Q0  
2Q1  
1Q0  
1Q1  
1F0  
1F1  
TEST  
These divided outputs, coupled with the Phase Locked Loop,  
allow the PSCB to multiply the clock rate at the REF input by  
either two or four. This mode will enable the designer to dis-  
tribute a low-frequency clock between various portions of the  
system, and then locally multiply the clock rate to a more suit-  
able frequency, while still maintaining the low-skew character-  
istics of the clock driver. The PSCB can perform all of the func-  
tions described above at the same time. It can multiply by two  
and four or divide by two (and four) at the same time that it is  
shifting its outputs over a wide range or maintaining zero skew  
between selected outputs.  
7B991112  
Figure 5. Frequency Multiplier with Skew Connections  
Figure 5 illustrates the PSCB configured as a clock multiplier.  
The 3Q0 output is programmed to divide by four and is fed  
back to FB. This causes the PLL to increase its frequency until  
the 3Q0 and 3Q1 outputs are locked at 20 MHz while the 1Qx  
and 2Qx outputs run at 80 MHz. The 4Q0 and 4Q1 outputs are  
programmed to divide by two, which results in a 40-MHz wave-  
form at these outputs. Note that the 20- and 40-MHz clocks fall  
Document #: 38-07209 Rev. **  
Page 9 of 12  
CY7B9911  
RoboClock+  
REF  
LOAD  
Z
0
80MHz  
INVERTED  
FB  
REF  
FS  
20MHz  
DISTRIBUTION  
CLOCK  
LOAD  
LOAD  
4Q0  
4Q1  
4F0  
4F1  
20MHz  
Z
0
3Q0  
3Q1  
2Q0  
2Q1  
3F0  
3F1  
2F0  
2F1  
80MHz  
ZEROSKEW  
Z
0
1Q0  
1Q1  
1F0  
LOAD  
80MHz  
SKEWED4ns  
1F1  
TEST  
Z
0
7B991114  
Figure 7. Multi-Function Clock Driver  
LOAD  
LOAD  
REF  
Z
0
L1  
FB  
SYSTEM  
CLOCK  
REF  
FS  
4F0  
4F1  
L2  
Z
0
4Q0  
4Q1  
3Q0  
3Q1  
3F0  
3F1  
LOAD  
L3  
2F0  
2F1  
2Q0  
2Q1  
Z
0
1F0  
1F1  
1Q0  
1Q1  
L4  
FB  
REF  
TEST  
FS  
LOAD  
4Q0  
4Q1  
4F0  
4F1  
3F0  
3F1  
2F0  
2F1  
1F0  
1F1  
Z
0
3Q0  
3Q1  
2Q0  
2Q1  
1Q0  
1Q1  
LOAD  
TEST  
7B991115  
Figure 8. Board-to-Board Clock Distribution  
Figure 8 shows the CY7B9911 connected in series to con-  
struct a zero-skew clock distribution tree between boards. De-  
lays of the downstream clock buffers can be programmed to  
compensate for the wire length (i.e., select negative skew  
equal to the wire delay) necessary to connect them to the mas-  
ter clock source, approximating a zero-delay clock tree. Cas-  
caded clock buffers will accumulate low-frequency jitter be-  
cause of the non-ideal filtering characteristics of the PLL filter.  
It is recommended that not more than two clock buffers be  
connected in series.  
Ordering Information  
Accuracy  
(ps)  
Package  
Name  
Operating  
Ordering Code  
CY7B99115JC  
CY7B99117JC  
Package Type  
Range  
500  
750  
J65  
J65  
32-Lead Plastic Leaded Chip Carrier  
32-Lead Plastic Leaded Chip Carrier  
Commercial  
Commercial  
Document #: 38-07209 Rev. **  
Page 10 of 12  
CY7B9911  
RoboClock+  
Package Diagrams  
32-Lead Plastic Leaded Chip Carrier J65  
Document #: 38-07209 Rev. **  
Page 11 of 12  
© Cypress Semiconductor Corporation, 2001. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use  
of any circuitry other than circuitry embodied in a Cypress Semiconductor product. Nor does it convey or imply any license under patent or other rights. Cypress Semiconductor does not authorize  
its products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress  
Semiconductor products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress Semiconductor against all charges.  
CY7B9911  
RoboClock+  
Document Title: CY7B9911 RoboClock+ Programmable Skew Clock Buffer (PSCB)  
Document Number: 38-07209  
Issue  
Date  
Orig. of  
Change  
REV.  
ECN NO.  
Description of Change  
**  
110342  
12/21/01  
SZV  
Change from Spec number: 38-00623 to 38-07209  
Document #: 38-07209 Rev. **  
Page 12 of 12  

相关型号:

CY7B9911-7JCT

PLL Based Clock Driver, 7B Series, 4 True Output(s), 0 Inverted Output(s), PQCC32, PLASTIC, LCC-32
CYPRESS

CY7B9911V

High-Speed Low-Voltage Programmable Skew Clock Buffer LV-PSCB
CYPRESS

CY7B9911V-5JC

High-Speed Low-Voltage Programmable Skew Clock Buffer LV-PSCB
CYPRESS

CY7B9911V-5JCT

High Speed Low Voltage Programmable Skew Clock Buffer
CYPRESS

CY7B9911V-5JXC

High Speed Low Voltage Programmable Skew Clock Buffer
CYPRESS

CY7B9911V-5JXCT

High Speed Low Voltage Programmable Skew Clock Buffer
CYPRESS

CY7B9911V-7JC

High-Speed Low-Voltage Programmable Skew Clock Buffer LV-PSCB
CYPRESS

CY7B9911V-7JCT

High Speed Low Voltage Programmable Skew Clock Buffer
CYPRESS

CY7B9911V-7JXC

High Speed Low Voltage Programmable Skew Clock Buffer
CYPRESS

CY7B9911V-7JXCT

High Speed Low Voltage Programmable Skew Clock Buffer
CYPRESS

CY7B9911V_07

High Speed Low Voltage Programmable Skew Clock Buffer
CYPRESS

CY7B9911V_11

High Speed Low Voltage Programmable Skew Clock Buffer
CYPRESS