CY22381SC [CYPRESS]
Three-PLL General Purpose FLASH Programmable Clock Generator; 三锁相环通用闪存可编程时钟发生器型号: | CY22381SC |
厂家: | CYPRESS |
描述: | Three-PLL General Purpose FLASH Programmable Clock Generator |
文件: | 总8页 (文件大小:145K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
CY22381
Three-PLL General Purpose FLASH
Programmable Clock Generator
• Non-volatile programming enables easy customi-
zation, ultra-fast turnaround, performance tweaking,
design timing margin testing, inventory control, lower
part count, and more secure product supply. Can also
Features
• Three integrated phase-locked loops
• Ultra-widedividecounters(eight-bitQ,eleven-bitP,and
be programmed multiple times which reduces
programming errors and provides an easy upgrade
path for existing designs
seven-bit post divide)
• Improved linear crystal load capacitors
• Flash programmability
• In-house programming of samples and prototype
quantities is available using the CY3672 FTG devel-
opmentKit.Productionquantitiesareavailablethrough
Cypress’s value-added distribution partners or by
using third party programmers from BP Microsystems,
HiLo Systems, and others.
• Performance suitable for high-endmultimedia, commu-
nications, industrial, A/D converters, and consumer
applications
• Field programmability
• Low-jitter, high-accuracy outputs
• Power-management options (Shutdown, OE, Suspend)
• Configurable crystal drive strength
• Frequency select option via external LVTTL Input
• 3.3V operation
• Eight-pin SOIC package
• CyClocks RT™ support
• Supports numerous low-power application schemes
and reduces EMI by allowing unused outputs to be
turned off
• Adjust crystal drive strength for compatibility with
Benefits
virtually all crystals
• External frequency select option for PLL1, CLKA, and
CLKB
• Industry standard supply voltage
• Industry standard packaging saves on board space
• Easy-to-use software support for design entry
• Generates up to three unique frequencies on three
outputs up to 200 MHz from an external source.
Functional upgrade for current CY2081 family.
• Allows for 0 ppm frequency generation and frequency
conversion under the most demanding applications
• Improves frequency accuracy over temperature, age,
process, and initial offset
Logic Block Diagram
XTALIN
OSC.
XTALOUT
PLL1
Divider
CLKC
7-BIT
11-BIT P
CONFIGURATION
FLASH
8-BIT Q
4 × 3
PLL2
11-BIT P
8-BIT Q
Crosspoint
Switch
Divider
7-BIT
CLKB
CLKA
SHUTDOWN/OE
FS/SUSPEND
PLL3
11-BIT P
8-BIT Q
Divider
7-BIT
Cypress Semiconductor Corporation
•
3901 North First Street
•
San Jose, CA 95134
•
408-943-2600
Document #: 38-07012 Rev. *D
Revised October 13, 2004
CY22381
Pin Configuration
CY22381
8-pin SOIC
CLKC
GND
FS/SUSPEND/OE/SHUTDOWN
1
2
3
4
8
7
6
5
VDD
XTALIN
XTALOUT
CLKA
CLKB
Selector Guide
Part Number Outputs
Input Frequency Range
Output Frequency Range
Specifics
CY22381FC
3
8 MHz – 30 MHz (external crystal) Up to 200 MHz
Commercial Temperature
1 MHz – 166 MHz (reference clock)
CY22381FI
3
8 MHz – 30 MHz (external crystal) Up to 166 MHz
1 MHz – 150 MHz (reference clock)
Industrial Temperature
Pin Summary
Name
CLKC
GND
XTALIN
XTALOUT
CLKB
Pin Number
Description
Configurable clock output C
Ground
Reference crystal input or external reference clock input
Reference crystal feedback (float if XTALIN is driven by external reference clock)
Configurable clock output B
Configurable clock output A
Power supply
1
2
3
4
5
6
7
8
CLKA
VDD
FS/SUSPEND/
General Purpose Input. Can be Frequency Control, Suspend mode control, Output
OE/SHUTDOWN
Enable, or full-chip shutdown.
General-Purpose Input
Operation
The CY22381 features an output control pin (pin 8) that can
The CY22381 is an upgrade to the existing CY2081. The new
device has a wider frequency range, greater flexibility,
improved performance, and incorporates many features that
reduce PLL sensitivity to external system issues.
The device has three PLLs that allow each output to operate
at an independent frequencies. These three PLLs are
completely programmable.
be programmed to control one of four features.
When programmed as a Frequency Select (FS), the input can
select between two arbitrarily programmed frequency settings.
The Frequency Select can change the following; the frequency
of PLL1, the output divider of CLKB, and the output divider of
CLKA. Any divider change as a result of switching the FS input
is guaranteed to be glitch free.
Configurable PLLs
The general-purpose input can simultaneously control the
Suspend feature, turning off a set of PLLs and outputs deter-
mined during programming.
PLL1 generates a frequency that is equal to the reference
divided by an eight-bit divider (Q) and multiplied by an 11-bit
divider in the PLL feedback loop (P). The output of PLL1 is sent
to the crosspoint switch. The frequency of PLL1 can optionally
be changed by using the external CMOS general purpose
input. See the following section on “General-Purpose Input” for
more detail.
PLL2 generates a frequency that is equal to the reference
divided by an eight-bit divider (Q) and multiplied by an 11-bit
divider in the PLL feedback loop (P). The output of PLL2 is sent
to the crosspoint switch.
When programmed as an Output Enable (OE) the input forces
all outputs to be placed in a three-state condition when LOW.
When programmed as a Shutdown, the input forces a full chip
shutdown mode when LOW.
Crystal Input
The input crystal oscillator is an important feature of this device
because of its flexibility and performance features.
The oscillator inverter has programmable drive strength. This
allows for maximum compatibility with crystals from various
manufacturers, processes, performances, and qualities.
The input load capacitors are placed on-die to reduce external
component cost. These capacitors are true parallel-plate
capacitors for ultra-linear performance. These were chosen to
reduce the frequency shift that occurs when non-linear load
PLL3 generates a frequency that is equal to the reference
divided by an eight-bit divider (Q) and multiplied by an 11-bit
divider in the PLL feedback loop (P). The output of PLL3 is sent
to the cross-point switch.
Document #: 38-07012 Rev. *D
Page 2 of 8
CY22381
capacitance interacts with load, bias, supply, and temperature
changes. Non-linear (FET gate) crystal load capacitors should
not be used for MPEG, POTS dial tone, communications, or
other applications that are sensitive to absolute frequency
requirements.
The value of the load capacitors is determined by six bits in a
programmable register. The load capacitance can be set with
a resolution of 0.375 pF for a total crystal load range of 6 pF
to 30 pF.
For driven clock inputs the input load capacitors may be
completely bypassed. This enables the clock chip to accept
driven frequency inputs up to 166 MHz. If the application
requires a driven input, then XTALOUT must be left floating.
Power-Saving Features
When configured as OE, the general-purpose input
three-states all outputs when pulled LOW. When configured as
Shutdown, a LOW on this pin three-states all outputs and
shuts off the PLLs, counters, the reference oscillator, and all
other active components. The resulting current on the VDD
pins will be less than 5 µA (typical). After leaving shutdown
mode, the PLLs will have to relock.
When configured as SUSPEND, the general-purpose input
can be configured to shut down a customizable set of outputs
and/or PLLs, when LOW. All PLLs and any of the outputs can
be shut off in nearly any combination. The only limitation is that
if a PLL is shut off, all outputs derived from it must also be shut
off. Suspending a PLL shuts off all associated logic, while
suspending an output forces a three-state condition.
Output Configuration
Under normal operation there are four internal frequency
sources that may be routed via a programmable crosspoint
switch to any of the three outputs via programmable seven-bit
output dividers. The four sources are: reference, PLL1, PLL2,
and PLL3. The following is a description of each output.
CLKA’s output originates from the crosspoint switch and goes
through a programmable seven-bit post divider. The seven-bit
post divider derives its value from one of two programmable
registers controlled by FS.
CLKB’s output originates from the crosspoint switch and goes
through a programmable seven-bit post divider. The seven-bit
post divider derives its value from one of two programmable
registers controlled by FS.
CLKC’s output originates from the crosspoint switch and goes
through a programmable seven-bit post divider. The seven-bit
post divider derives its value from one programmable register.
Improving Jitter
Jitter Optimization Control is useful in mitigating problems
related to similar clocks switching at the same moment and
causing excess jitter. If one PLL is driving more than one
output, the negative phase of the PLL can be selected for one
of the outputs. This prevents the output edges from aligning,
allowing superior jitter performance.
CyClocks RT Software
CyClocks RT is our second-generation application that allows
users to configure this device. The easy-to-use interface offers
complete control of the many features of this family including
input frequency, PLL and output frequencies, and different
functional options. Data sheet frequency range limitations are
checked and performance tuning is automatically applied. You
can download a free copy of CyClocks RT on Cypress’s web
site at http://www.cypress.com.
The Clock outputs have been designed to drive a single point
load with a total lumped load capacitance of 15 pF. While
driving multiple loads is possible with the proper termination,
it is generally not recommended.
Document #: 38-07012 Rev. *D
Page 3 of 8
CY22381
Junction Temperature.................................................. 125°C
Data Retention @ Tj = 125°C................................> 10 years
Maximum Programming Cycles........................................100
Package Power Dissipation...................................... 250 mW
Static Discharge Voltage
Maximum Ratings
(Above which the useful life may be impaired. For user guide-
lines, not tested.)
Supply Voltage............................................... –0.5V to +7.0V
DC Input Voltage.............................. –0.5V to + (VDD + 0.5V)
Storage Temperature ..................................–65°C to +125°C
(per MIL-STD-883, Method 3015) ........................... ≥ 2000V
Latch up (per JEDEC 17) .................................... ≥ ±200 mA
Operating Conditions[1]
Parameter
VDD
Description
Min.
3.135
0
–40
–
8
1
1
0.05
Typ.
3.3
–
–
–
–
–
–
–
Max.
3.465
+70
+85
15
Unit
V
°C
°C
pF
MHz
MHz
MHz
ms
Supply Voltage
TA
Commercial Operating Temperature, Ambient
Industrial Operating Temperature, Ambient
Max. Load Capacitance
CLOAD_OUT
fREF
External Reference Crystal
30
External Reference Clock[2], Commercial
External Reference Clock[2], Industrial
166
150
500
tPU
Power-up time for all VDD's to reach minimum specified voltage
(power ramps must be monotonic)
Electrical Characteristics
Parameter
IOH
IOL
CXTAL_MIN
Description
Output High Current[3]
Output Low Current[3]
Conditions
VOH = VDD – 0.5, VDD = 3.3 V
VOL = 0.5V, VDD = 3.3 V
Min.
Typ.
Max.
–
–
–
–
Unit
mA
mA
pF
pF
pF
VDD
VDD
µA
µA
µA
12
12
–
–
–
70%
–
–
–
–
24
24
6
30
7
Crystal Load Capacitance[3] Capload at minimum setting
CXTAL_MAX Crystal Load Capacitance[3] Capload at maximum setting
CIN
VIH
VIL
IIH
IIL
IOZ
IDD
Input Pin Capacitance[3]
HIGH-level Input Voltage
LOW-level Input Voltage
Input HIGH Current
Input LOW Current
Output Leakage Current
Except crystal pins
CMOS levels,% of VDD
CMOS levels,% of VDD
VIN = VDD – 0.3 V
VIN = +0.3 V
–
–
–
–
30%
10
10
10
–
<1
<1
–
35
70
5
Three-state outputs
Total Power Supply Current 3.3 V Power Supply; 3 outputs @ 50 MHz
3.3 V Power Supply; 3 outputs @ 166 MHz
–
–
–
mA
mA
µA
–
20
IDDS
Total Power Supply Current in Shut-down active
Shutdown Mode
Notes:
1. Unless otherwise noted, Electrical and Switching Characteristics are guaranteed across these operating conditions.
2. External input reference clock must have a duty cycle between 40% and 60%, measured at V /2.
DD
3. Guaranteed by design, not 100% tested.
Document #: 38-07012 Rev. *D
Page 4 of 8
CY22381
Switching Characteristics
Parameter
1/t1
Name
Description
Clock output limit, Commercial
Clock output limit, Industrial
Duty cycle for outputs, defined as t2 ÷ t1,
Fout < 100 MHz, divider >= 2, measured
at VDD/2
Min.
–
–
Typ.
–
–
Max.
200
166
Unit
MHz
MHz
Output Frequency[3, 4]
t2
Output Duty Cycle[3, 5]
45%
50%
55%
Duty cycle for outputs, defined as t2 ÷ t1,
Fout > 100 MHzordivider = 1,measured
at VDD/2
Output clock rise time, 20% to 80% of VDD 0.75
Output clock fall time, 20% to 80% of VDD 0.75
Time for output to enter or leave
three-state mode after SHUTDOWN/OE
switches
40%
50%
60%
t3
t4
t5
Rising Edge Slew Rate[3]
Falling Edge Slew Rate[3]
Output Three-state Timing[3]
1.4
1.4
150
–
–
300
V/ns
V/ns
ns
–
t6
t7
Clock Jitter[3, 6]
Lock Time[3]
Peak-to-peak period jitter, CLK outputs
–
–
200
1.0
–
3
ps
measured at VDD/2
PLL Lock Time from Power-up
ms
Switching Waveforms
All Outputs, Duty Cycle and Rise/Fall Time
t
1
t
2
OUTPUT
t
3
t
4
Output Three-State Timing
OE
t
5
t
5
ALL
THREE-STATE
OUTPUTS
CLK Output Jitter
t
6
CLK
OUTPUT
Notes:
4. Guaranteed to meet 20% – 80% output thresholds and duty cycle specifications.
5. Reference Output duty cycle depends on XTALIN duty cycle.
6. Jitter varies significantly with configuration. Reference Output jitter depends on XTALIN jitter and edge rate.
Document #: 38-07012 Rev. *D
Page 5 of 8
CY22381
Switching Waveforms (continued)
Frequency Change
OLD SELECT
NEW SELECT STABLE
SELECT
t
7
F
new
F
old
OUTPUT
Test Circuit
VDD
0.1 mF
OUTPUTS
CLKout
CLOAD
GND
Ordering Information
Ordering Code
Package Type
Operating Range
Operating Voltage
CY22381FC
CY22381FCT
CY22381FI
CY22381FIT
8-SOIC
8-SOIC – Tape and Reel
8-SOIC
8-SOIC – Tape and Reel
8-SOIC
8-SOIC – Tape and Reel
8-SOIC
Commercial (TA=0°C to 70°C)
Commercial (TA=0°C to 70°C)
Industrial (TA=–40°C to 85°C)
Industrial (TA=–40°C to 85°C)
Commercial (TA=0°C to 70°C)
Commercial (TA=0°C to 70°C)
Industrial (TA=–40°C to 85°C)
Industrial (TA=–40°C to 85°C)
3.3V
3.3V
3.3V
3.3V
3.3V
3.3V
3.3V
3.3V
CY22381SC-xxx[7]
CY22381SC-xxxT[7]
CY22381SI-xxx[7]
CY22381SI-xxxT[7]
CY3672
8-SOIC – Tape and Reel
Lead-Free
CY22381FXC
CY22381FXCT
CY22381FXI
8-SOIC
8-SOIC – Tape and Reel
8-SOIC
8-SOIC – Tape and Reel
8-SOIC
8-SOIC – Tape and Reel
8-SOIC
Commercial (TA=0°C to 70°C)
Commercial (TA=0°C to 70°C)
Industrial (TA=–40°C to 85°C)
Industrial (TA=–40°C to 85°C)
Commercial (TA=0°C to 70°C)
Commercial (TA=0°C to 70°C)
Industrial (TA=–40°C to 85°C)
Industrial (TA=–40°C to 85°C)
3.3V
3.3V
3.3V
3.3V
3.3V
3.3V
3.3V
3.3V
CY22381FXIT
CY22381SXC-xxx[7]
CY22381SXC-xxxT[7]
CY22381SXI-xxx[7]
CY22381SXI-xxxT[7]
8-SOIC – Tape and Reel
Notes:
7. The CY22381SC-xxx and CY22381SI-xxx are factory programmed configurations. Factory programming is available for high-volume design opportunities of
100Ku/year or more in production. For more details, contact your local Cypress FAE or Cypress Sales Representative.
Document #: 38-07012 Rev. *D
Page 6 of 8
CY22381
Package Drawing and Dimensions
8 Lead (150 Mil) SOIC - S08
8-lead (150-Mil) SOIC S8
PIN 1 ID
4
1
1. DIMENSIONS IN INCHES[MM] MIN.
MAX.
2. PIN 1 ID IS OPTIONAL,
ROUND ON SINGLE LEADFRAME
RECTANGULAR ON MATRIX LEADFRAME
0.150[3.810]
0.157[3.987]
3. REFERENCE JEDEC MS-012
4. PACKAGE WEIGHT 0.07gms
0.230[5.842]
0.244[6.197]
PART #
S08.15 STANDARD PKG.
SZ08.15 LEAD FREE PKG.
5
8
0.189[4.800]
0.196[4.978]
0.010[0.254]
0.016[0.406]
X 45°
SEATING PLANE
0.061[1.549]
0.068[1.727]
0.004[0.102]
0.050[1.270]
BSC
0.0075[0.190]
0.0098[0.249]
0.004[0.102]
0.0098[0.249]
0°~8°
0.016[0.406]
0.035[0.889]
0.0138[0.350]
0.0192[0.487]
51-85066-*C
CYClocks RT is a trademark of Cypress Semiconductor Corporation. All product and company names are the trademarks of their
respective holders.
Document #: 38-07012 Rev. *D
Page 7 of 8
CY22381
Document History Page
Document Title: CY22381 Three-PLL General Purpose Flash Programmable Clock Generator
Document Number: 38-07012
Orig. of
REV.
**
ECN NO. Issue Date Change
Description of Change
106737
07/03/01
TLG
New data sheet
*A
108514
08/23/01
JWK
Updated based on characterization results
Removed “Preliminary” heading
Removed soldering temperature rating
Split crystal load into two typical specs representing digital settings range
Changed t5 max to 300 ns
Changed t6 typical to 200 ps
Changed t7 typical to 1.0 ms
*B
*C
*D
110053
121863
279431
12/10/01
12/14/02
See ECN
CKN
RBI
RGL
Changed from preliminary to final
Added power-up requirements to Operating Conditions information
Added lead-free devices
Document #: 38-07012 Rev. *D
Page 8 of 8
相关型号: