VIFSD1-S24-S15-DIP [CUI]
DC-DC Converter; DC-DC变换器型号: | VIFSD1-S24-S15-DIP |
厂家: | CUI INC |
描述: | DC-DC Converter |
文件: | 总3页 (文件大小:106K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
1 / 3
VIFSD1-DIP Series DC-DC Converter
Rev. 01-2006
Description
Features
Designed to convert fixed volt-
ages into an isolated regulated
voltage, the VIFSD1-DIP series is
well suited for providing board-
mount local supplies in a wide
range of applications, including
mixed analog/digital circuits, test
& measurement equip.,
·Isolated 1 W output
·Regulated
·High efficiency to 73%
·Single voltage output
·Small footprint
·DIP package style
·Industry standard pinout
·UL94-V0 package
process/machine controls, data-
com/telecom fields, etc...
·No heatsink required
·3K Vdc isolation
·Temperature range: -40°C~+85°C
·No external component required
·Low cost
Model
Input Voltage
Output
Voltage
5 Vdc
Output Current
Package
Style
DIP
Number
Nominal
5 Vdc
Range
Max.
150 mA
111 mA
83mA
Min.
15 mA
12 mA
9 mA
Efficiency
69%
VIFSD1-S5-S5-DIP
VIFSD1-S5-S9-DIP
VIFSD1-S5-S12-DIP
VIFSD1-S5-S15-DIP
VIFSD1-S12-S5-DIP
VIFSD1-S12-S9-DIP
VIFSD1-S12-S12-DIP
VIFSD1-S12-S15-DIP
VIFSD1-S24-S5-DIP
VIFSD1-S24-S9-DIP
VIFSD1-S24-S12-DIP
VIFSD1-S24-S15-DIP
4.75~5.25 Vdc
4.75~5.25 Vdc
4.75~5.25 Vdc
4.75~5.25 Vdc
11.4~12.6 Vdc
11.4~12.6 Vdc
11.4~12.6 Vdc
11.4~12.6 Vdc
22.8~25.2 Vdc
22.8~25.2 Vdc
22.8~25.2 Vdc
22.8~25.2 Vdc
5 Vdc
9 Vdc
70%
DIP
5 Vdc
12 Vdc
15 Vdc
5 Vdc
71%
DIP
5 Vdc
67 mA
150 mA
111 mA
83 mA
67 mA
150 mA
111 mA
83 mA
67 mA
7 mA
72%
DIP
12 Vdc
12 Vdc
12 Vdc
12 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
15 mA
12 mA
9 mA
69%
DIP
9 Vdc
71%
DIP
12 Vdc
15 Vdc
5 Vdc
72%
DIP
7 mA
72%
DIP
15 mA
12 mA
9 mA
70%
DIP
9 Vdc
72%
DIP
12 Vdc
15 Vdc
73%
DIP
7 mA
73%
DIP
Note:
1. All specifications measured at TA=25°C, humidity <75%, nominal input voltage and rated output load unless
otherwise specified.
Output Specifications
Item
Test conditions
Min.
Typ.
Max.
1
Units
W
Output power
0.1
Line Regulation
Load Regulation
Output voltage accuracy
Temperature drift
Output ripple & noise
Switching frequency
For Vin change of 1%
10% to 100% full load
100% full load
0.25
1
%
%
±3
100% full load
0.03
15
%/°C
mVp-p
KHz
20Hz - 300 KHz Bandwidth
Full load, nominal input
10
100
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
www.v-infinity.com
1-866-372-1258
2 / 3
VIFSD1-DIP Series DC-DC Converter
Rev. 01-2006
General Specifications
Short circuit protection
Temperature rise at full load
Cooling
<1 second
25°C Max, 15°C Typ.
Free air convection
-40°C to +85°C
-55°C to +125°C
Operating temperature range
Storage temperature range
Soldering temperature
Storage humidity range
Case material
<= 300°C (1.5mm from case for 10 sec.)
<95%
Plastic (UL94-V0)
MTBF
>3,500,000 hrs.
Burn-in
At +85°C, for 4 hours at no-load and 4 hours at full load.
Isolation Specifications
Item
Test Conditions
Min.
3000
1000
Typ.
Max.
Units
Vdc
Isolation Voltage
Insulation Resistance
Tested for 1 min.
Test at 500 Vdc
M Ω
Typical Characteristics
Temperature Derating Graph
Safe Operating Area
71 85
(
)
Ambient Temperature
Outline Dimensions &
Recommended Layout Pattern
Side View
Layout
7
1
9
14
Bottom View
Pin
1
7
9
11
14
-Vin
NC
+Vout
-Vout
+Vin
7
1
9
14
Note: All Pins on a 2.54mm pitch; All Pin diameters are 0.50 mm; all dimensions in mm.
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
www.v-infinity.com
1-866-372-1258
3 / 3
VIFSD1-DIP Series DC-DC Converter
Rev. 01-2006
- Minimum loading
Application Notes:
The converter needs a minimum of 10% loading to
maintain output regulation. Operation under no-load
conditions will not cause immediate damages but
may reduce reliability, and cause performance not to
meet specifications.
- Input filtering
To reduce the reflected ripple current and minimize
EMI, especially when the converter input is more
than 2” away from the DC source, it is recommended
to connect a low ESR electrolytic capacitor between
Vin and Gnd. The values suggested are as shown in
Table 1. If additional filtering is required, the
capacitance may be increased, or expanded to an LC
network as shown in Figure 1.
- Protection
The converter has minimal protection against input
over-voltage or output over-load, and may be
permanently damaged if exposed to these conditions.
An input clamping device can be used for input
voltage limiting. An input fuse or an output fuse
can also be used to protect against over-loading.
Table 1
Input Voltage
5 V
External Input Capacitance
- Unregulated input
4.7 µF
2.2 µF
1.0 µF
As fixed input converters, this series can accept
voltages within a limited range of the nominal input.
Otherwise the converter may not function properly or
may be damaged. An optional regulator can be used
at the input to bring voltage within regulation, as
shown in Figure 2.
12 V
24 V
- Output filtering
An output capacitor as shown in Table 2 may be used
to reduce output ripples and noise.
requirements as shown in Table 2.
+Vout
Output capacitance may be increased for additional
filtering, but should not exeed 10µF. It can also be
expanded to an LC network as in Figure 1.
+Vin
-Vin
REG
DC DC
-Vout
<Figure 2>
Table 2
External Ouput Capacitance
Vout
5 V
4.7 µF
2.2 µF
1.0 µF
0.47 µF
9 V
12 V
15 V
L
L
+Vout
+Vin
-Vin
C
C
DC DC
-Vout
<Figure 1>
V-Infinity, LLC, 20050 SW 112th Ave., Tualatin, OR 97062
www.v-infinity.com
1-866-372-1258
相关型号:
©2020 ICPDF网 联系我们和版权申明