PSA-1100-12-B4 [CUI]

AC-DC HOT-SWAP POWER SUPPLY;
PSA-1100-12-B4
型号: PSA-1100-12-B4
厂家: CUI INC    CUI INC
描述:

AC-DC HOT-SWAP POWER SUPPLY

文件: 总11页 (文件大小:571K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
For more information, please visit the product page.  
date 07/15/2015  
page 1 of 11  
SERIES: PSA-1100 DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY  
FEATURES  
• up to 1100 W continuous power  
• high power density - 25.34 W/in3  
• slim line 1U form factor  
• PMBusTM communication for monitoring and control  
• front to back (-F) and back to front (-B) airflow versions  
• power factor correction  
• 3.3 Vdc or 5 Vdc standby voltage (2 A) options  
• redundant (N+1) operation  
• blind mate connections for hot-swap  
• DROOP current sharing or forced current sharing (optional)  
• remote on/off control, power good signal  
C
US  
m
output  
voltage  
output  
current  
max  
output  
power  
max  
ripple  
efficiency2  
MODEL  
and noise1  
max  
typ  
(Vdc)  
12  
(A)  
(W)  
(mVp-p)  
(%)  
PSA-1100-12-F  
PSA-1100-12-B3,4,5  
92  
92  
1100  
1100  
120  
120  
93.5  
93.5  
12  
Notes:  
1. Measured at 20 MHz bandwidth at an oscilloscope jack on the output with 0.1 µF ceramic and two 180 µF polymer capacitors at a 2” distance from V1 output connector.  
2. At 230 Vac input, 550 W.  
3. At 100~240 Vac input, maximum of 1100 W at Ta=29°C.  
4. At 100~240 Vac input, maximum of 740 W at Ta=50°C.  
5. At 200~240 Vac input, maximum of 1100 W at Ta=48°C.  
6. All specifications measured at: Ta=25°C and 220 Vac input voltage unless otherwise specified.  
PART NUMBER KEY  
PSA-1100 - 12 - X - CXX  
Base Number  
Reserved for Custom  
Configurations  
Output Voltage  
Airflow Direction:  
F = AC input connector to DC output connector  
B = DC output connector to AC input connector  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSA-1100 DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY  
date 07/15/2015 page 2 of 11  
INPUT  
parameter  
voltage  
conditions/description  
min  
90  
typ  
max  
264  
63  
units  
Vac  
frequency  
47  
Hz  
at 90 Vac  
at 180 Vac  
14.4  
8.0  
Arms  
Arms  
current  
at 115 Vac, cold start  
at 230 Vac, cold start  
20  
40  
A
A
inrush current  
leakage current  
1.5  
mArms  
power factor correction  
at 115 Vac, full load  
0.95  
(
)
OUTPUT - V1 MAIN OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
%
line regulation  
load regulation  
load capacitance  
±1.5  
±1.5  
%
30,000  
5
μF  
25% step load, 1A/µs slew rate, recovery to 1%  
within 1 ms  
transient response  
%
start-up time  
hold-up time  
remote sense  
1.5  
s
ms  
V
at 230 Vac, full load  
12  
between both output terminals  
0.3  
±4  
current share accuracy (Droop)1 over 10% to 100% load  
A
AC OK: “green” to indicate AC above the lower  
limit that is required to sustain normal operation  
LED indicator  
DC OK: “green” to indicate module in normal  
operating condition  
Notes:  
1. Droop regulation of ±1.0% for an overall combined regulation allowance of ±1.5%  
PSA-1100 Droop Regulation Proꢀle  
12.15  
12.12  
12.10  
12.05  
12  
12.00  
PSA-1100 Droop  
Regulation Proꢀle  
11.95  
11.90  
11.88  
11.85  
0%  
20%  
40%  
60%  
80%  
100%  
Module % Full Load Current  
(
)
OUTPUT - V2 STANDBY OUTPUT  
parameter  
conditions/description  
min  
typ  
max  
units  
Vdc  
A
output voltage  
output current  
ripple and noise2  
line regulation  
load regulation  
load capacitance  
selectable  
3.3/5  
0
2
100  
mVp-p  
%
±2  
±2  
%
2200  
5
µF  
25% step load, 1A/µs slew rate, recovery to 1%  
transient response  
start-up time  
%
s
within 1 ms  
1.5  
Notes:  
2. Measured at 20 MHz bandwidth at an oscilloscope jack on the output with 100 µF low ESR capacitor at 0.5” from V2 output connector.  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSA-1100 DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY  
date 07/15/2015 page 3 of 11  
PROTECTIONS  
parameter  
conditions/description  
min  
typ  
max  
units  
V1: latch off  
V2: latch off  
13.2  
110  
14.5  
120  
Vdc  
%
over voltage protection  
V1: auto recovery  
V2  
101.2  
128.8  
3
A
A
over current protection  
over temperature protection  
auto recovery  
55  
°C  
SAFETY & COMPLIANCE  
parameter  
conditions/description  
min  
typ  
max  
units  
insulation safety rating / test  
voltage  
input to output, reinforced  
input to chassis, basic  
3,000  
1,500  
Vrms  
Vrms  
output to chassis  
V2 to chassis/ground  
100  
100  
Vrms  
Vdc  
isolation voltage  
grounding  
the output signals are referenced to the A2 and B2  
return connection  
EN60950-1:2006+A11+A1+A12, IEC60950-1:2005+Amd 1,  
CAN/CSA-C22.2 No.60950-1-07+A1:2011, UL 60950-1:2007  
R12.11(NRTL Route), EEC/93/68/LVD, 2006/95/EC LVD  
safety approvals  
conducted emissions  
radiated emissions  
FCC 15 Sub Part B, EN55022, Class A: tested with resistive load  
FCC 15 Sub Part B, EN55022, Class A: tested with resistive load  
EN/IEC 61000-3-2:2009, Class A Harmonic Limits  
Compliance Level: 230 Vac line voltage; 100% output load  
harmonic compliance  
EN/IEC 61000-3-3:2009 limits as specified in the standard:  
flicker and voltage fluctuations  
flicker  
EN/IEC 61000-4-2, ±8 kV operational air discharge, ±8 kV  
contact discharge: all parameters to remain within limits, test  
set up to be defined  
electrostatic discharge  
RF electro-magnetic  
field. amplitude  
modulated  
EN/IEC 61000-4-3 80~1000 MHz, 10 V/m, 80% AM  
Modulation (1 kHz): all parameters to remain within limits, test  
set up to be defined  
immunity to fast  
transients  
EN/IEC 61000-4-4 Power lines: ±2 kV: all parameters to remain  
within limits, test set up to be defined  
EN/IEC 61000-4-5 ±1kV line to line, ±2 kV line to earth,  
Criteria A: all parameters to remain within limits, test set up to  
be defined  
surges (mains)  
EN/IEC 61000-4-6 150 kHz~80 MHz 3Vrms 80% AM (1 kHz),  
Criteria A: all parameters to remain within limits, test set up to  
be defined  
RF continuous  
conducted  
IEC 61000-4-11 30% reduction for 10 ms, 60% reduction for  
100 ms: Reset is permitted must be selfrecovering. Additionally,  
the PSU shall not latch up during any brownout condition.  
voltage dips/  
interruptions  
as per Telcordia SR-332, Issue 2, Sept 2006  
500,000  
MTBF  
hours  
component stress method at Ta=40°C, full load  
RoHS  
WEEE  
2011/65/EU  
2012/19/EU  
ENVIRONMENTAL  
parameter  
operating temperature1  
storage temperature  
operating humidity  
storage humidity  
conditions/description  
min  
0
typ  
max  
50  
units  
°C  
non-condensing  
non-condensing  
-40  
10  
5
70  
°C  
90  
%
90  
%
Notes:  
1. PSA-1100-12-B: At 100~240 Vac input, maximum of 1100 W at Ta=29°C. At 100~240 Vac input, maximum of 740 W at Ta=50°C. At 200~240 Vac input, maximum of  
1100 W at Ta=48°C.  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSA-1100 DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY  
date 07/15/2015 page 4 of 11  
(
)
ENVIRONMENTAL CONTINUED  
parameter  
conditions/description  
min  
typ  
max  
units  
acoustic  
ISO 7779-1999  
60  
dB LpAm  
cold1  
IEC 68 Part 2 – 1: at -10°C minimum for 4 hours  
IEC 68 Part 2 – 2: at 50°C minimum for 4 hours  
IEC 68 Part 2 – 30: at 20~45°C, 30~95 %RH  
IEC 68 Part 2 – 13: at 10,000 feet, 697 mbar  
dry heat  
damp heat, cyclic  
low air pressure (operating)  
IEC 68 Part 2 – 6: at 10~58 Hz, 0.075 mm;  
58~500 Hz, 10 m/s2, 1 octave/minute, 10 cycles/  
main axis  
vibration (sinusoidal)  
1
G
IEC 68 Part 2 – 27: at 300 m/s2, 11 ms, half sine  
wave 3 shocks/main axis  
IEC 68 Part 2 – 29: at 150 m/s2, 6 ms, half sine  
wave 900 bumps/main axis  
shock  
bump  
30  
15  
G
G
Notes:  
1. The module shall start up at -10°C, however it is not required that the full specification is achieved until the operational internal temperature has risen to 0°C.  
MECHANICAL  
parameter  
conditions/description  
min  
typ  
max  
units  
inches  
kg  
dimensions  
12.65 x 2.145 x 1.575 (321.3 x 54.5 x 40.0 mm)  
weight  
1.1  
cooling / airflow  
material flammability  
AC input  
integral fan  
UL 94V-0  
IEC320/C14  
Tyco Electronics P/N 2-1926734-2  
mates with Tyco Electronics P/N 2-1926739-5  
DC output  
MECHANICAL DRAWING  
units: inches [mm]  
tolerance:  
X.XX ±0.02 [0.50]  
X.XXX ±0.010 [0.25]  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSA-1100 DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY  
date 07/15/2015 page 5 of 11  
DC OUTPUT PIN ASSIGNMENTS  
PIN  
FUNCTION  
12 V output return  
12 V output  
DESCRIPTION  
V1 (-VE) main output return  
V1 (+VE) main output  
HIGH / LOW LEVEL  
Imax  
1,2,3,4,5  
6,7,8,9,10  
A1  
Vstandby +VE  
signal/logic return  
I2C address select  
SCL  
positive output of standby (V2)  
common with V1 & V2 returns  
analog I2C address selection  
communications clock line  
A2  
A3  
A4  
signal  
pin row  
“A”  
disables power on extraction (recessed pin)  
pin status  
open circuit  
logic “1”  
module  
“off”  
A5  
PSKILL_H  
“off”  
logic “0”  
“on”  
B1  
B2  
B3  
Vstandby +VE  
signal/logic return  
not use  
positive output of standby (V2)  
common with V1 & V2 Returns  
reserved  
signal  
pin row  
“B”  
internally pulled up to 3.3 V via 3.01 kΩ if  
PSKILL_H is connected to return  
PS_ON_L  
(remote_ON_L)  
B4  
open to A2/B2  
short to A2/B2  
“off”  
“on”  
1.05 mA  
B5  
C1  
C2  
C3  
Ishare (optional)  
Vstandby +VE  
not use  
active current sharing bus (recessed pin)  
positive output of standby (V2)  
reserved  
SDA  
communications data  
SMBus interrupt line  
signal  
pin row  
“C”  
C4  
C5  
SMB_ALERT_L  
DC_OK_H  
logic “1”  
logic “0”  
“good”  
>2.1 V  
<0.4 A  
“fault”  
-5 mA  
-5 mA  
DC OK Signal (recessed pin)  
logic “1”  
logic “0”  
“good”  
>2.1 V  
<0.4 A  
“fault”  
D1  
D2  
D3  
D4  
Vstandby +VE  
not use  
positive output of standby (V2)  
reserved  
V1 Vsense (-VE)  
not use  
V1 negative sense line  
reserved  
signal  
pin row  
“D”  
selects the voltage of V2 recessed pin  
Vstandby_select  
(V2)  
D5  
open circuit  
3.3 V  
short circuit  
5 V  
E1  
E2  
E3  
Vstandby +VE  
not use  
positive output of standby (V2)  
reserved  
V1 Vsense (+VE)  
V1 positive sense line  
AC incoming source alarm  
signal  
pin row  
“E”  
E4  
E5  
AC_OK_H  
logic “1”  
logic “0”  
“good”  
> 2.1 V  
< 0.4 A  
“fault”  
-5 mA  
active low, recessed pin, passive signal to detect presence of module, host to provide pull up  
PS_present  
resistor connected to V2 to source maximum of 5 mA when module is inserted  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSA-1100 DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY  
date 07/15/2015 page 6 of 11  
APPLICATION NOTES  
Digital Interface  
The PSA-1100 is provided with a digital communications interface that is based upon a subset of the SMBus™ & PMBus™  
Protocols.  
The communication interface is a Two Wire Interface (TWI) using devices hardware compatible with I2C.  
The interface is based upon the I2C Protocol developed by Philips Semiconductors (now NXP). Reference to the “I2C Bus  
Specification and User Manual” UM10204 Rev.03 – 19 June 2007 is recommended.  
Slave Addresses  
The device is selected by setting the Slave Address (Pin A3) either by an external resistor network or by direct connection  
to logic “high” or “low. Either method interfaced to the appropriate I/O port of the internal I2C device. Therefore the device  
can be set to respond to all addresses in the range from binary 1011 0000 to 1011 0110 (where the last bit is for read/  
write that is always set at “0” for initial addressing).  
• Connection of Pin A3 to a logic “low” will provide an address of B0 (1011 0000)  
• Connection of Pin A3 to a logic “high” (or leaving open circuit) will provide an address of B6 (1011 0110)  
To achieve the full range of four potential address combinations Pin A3 requires to be connected to an external resistor  
that will create an internal analogue voltage that is interpreted by the internal I2C device to derive the following address  
combinations:  
Possible Module Slave Address Combinations  
External Resistor  
Value (Ohms)  
Fixed Address  
Bit 6 Bit 5  
Variable Address Bits  
R/W  
HEX  
Bit 7  
Bit 4  
Bit 3  
Bit 2  
Bit 1  
Bit 0  
820  
1
1
1
1
0
0
0
0
1
1
1
1
1
1
1
1
0
0
0
0
0
0
1
1
0
1
0
1
0
0
0
0
B0  
B2  
B4  
B6  
2700  
5600  
8200  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSA-1100 DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY  
date 07/15/2015 page 7 of 11  
(
)
APPLICATION NOTES CONTINUED  
General Information  
Refer to the PMBus™/SMBus specification for details on read/write operations when dealing with Byte, Word or Block  
process calls. Packet Error Correction (PEC) and Address Resolution Protocol (ARP) are not supported. If the PMBusTM  
master tries to read more bytes than the length of the data selected by the command code, the additional bytes will be  
sent as 0xFF. The PMBusTM slave device may apply clock stretching by holding the clock line (SCL) low after a command to  
indicate that it is busy processing data. A master device on the PMBusTM may attempt to continue with the communications  
but must first wait until the clock line is released. Clock stretching times will vary depending on the data being processed  
and/or if there are any higher priority events during the response but shall not exceed 25 ms.  
PMBus™ COMMAND SUBSET  
The following is subset of commands (extracted from the “PMBus Power System Management Protocol Specification; Part  
II Command Language; Rev 1.2, 6 September 2010”) and apply on a per module basis, (although certain commands could  
be applied “globally”). For a full definition of the individual command refer to the above referenced PMBusTM specification.  
Note:  
Hex Command 88h, 89h, 8Bh, 8Ch divide decimal value by 100.  
Command  
(HEX)  
Command  
Name  
No. of Read /  
Command Description  
Bytes  
Write  
The OPERATION command is used to turn the unit on & off in  
conjunction with the CONTROL (short; last make, first make pin).  
The unit remains in the commanded mode until the command is toggled or  
the unit removed from its slot; in which case the CONTROL pin is de-asserted  
and overrules the OPERATION command.  
01h  
OPERATION  
1
W
03h  
78h  
CLEAR_FAULTS  
STATUS_BYTE  
0
1
W
R
Clear fault data  
Lower byte returned from the STATUS_WORD  
The command returns two bytes of data relating to the unit fault  
condition. CUI may elect to provide a subset of information.  
79h  
STATUS_WORD  
2
R
88h  
89h  
8Bh  
8Ch  
READ_VIN  
READ_IIN  
2
2
2
2
R
R
R
R
Provides the measured input voltage of the power module in volts.  
Provides the measured input current of the power module in Amps.  
Provides the measured output voltage of the power module in volts.  
Provides the measured output current of the power module in Amps.  
READ_VOUT  
READ_IOUT  
This command shall return a select component temperature used by the  
power module, in degrees Celsius.  
8Dh  
READ_TEMPERATURE_1  
2
R
This command shall return the prevailing internal ambient of the power  
module, in degrees Celsius.  
8Eh  
90h  
96h  
READ_TEMPERATURE_2  
READ_FAN_SPEED_1  
READ_POUT  
2
2
2
R
R
R
Provides the measured fan speed in the power module in RPM.  
This command shall return the calculated output being delivered by  
the power module, in Watts.  
This command shall return the calculated input being drawn by the  
power module, in Watts.  
97h  
READ_PIN  
2
R
98h  
99h  
9Ah  
PMBUS_REVISION  
MFR_ID  
1
8
R
R
R
PMBusTM Revision  
The command returns the ASCII string for manufacturer’s ID.  
The command returns the ASCII string manufacturer’s model.  
MFR_MODEL  
12  
The command returns the ASCII string manufacturer’s revision (example  
case “01”).  
9Bh  
MFR_REVISION  
2
R
The command returns the ASCII string manufacturer’s date code  
(example case “0913”).  
9Dh  
9Eh  
MFR_DATE  
4
8
R
R
MFR_SERIAL  
The command returns manufacturers serial number.  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSA-1100 DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY  
date 07/15/2015 page 8 of 11  
(
)
APPLICATION NOTES CONTINUED  
PMBusTM Non-Standard Extended Command Subset  
Command  
(HEX)  
Command  
Name  
No. of Read /  
Command Description  
Read vendor specific firmware revision (ASCII string). Example case "A100"  
Bytes  
Write  
16h  
SOFTWARE VERSION  
4
R
Remote On/Off (PMBusTM Operation Command 0x01)  
This command can be used to turn the unit on and off via the PMBusTM interface.  
If B4 (REMOTE_ENABLE) is HIGH (enabled) then the PMBusTM Remote On/Off function can turn the unit off and on. If B4  
(REMOTE_ENABLE) is LOW (disabled) then the PMBusTM Remote On/Off function cannot turn the unit on or off and can be  
ignored.  
The bit encoding of the data byte of the command is as follows.  
Bits [7:6]  
Bits [5:4]  
Bits [3:2]  
Bits [1:0]  
Unit State  
00  
01  
10  
10  
10  
10  
10  
XX  
XX  
00  
01  
01  
10  
10  
XX  
XX  
XX  
01  
10  
01  
10  
XX  
XX  
XX  
XX  
XX  
XX  
XX  
Off  
Off  
On  
On  
On  
On  
On  
If any other bit pattern is received take no action.  
If the power supply is turned off by this command then set the OFF bit (6 of the low byte) of the status word to 1.  
Otherwise set it to 0.  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSA-1100 DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY  
date 07/15/2015 page 9 of 11  
(
)
APPLICATION NOTES CONTINUED  
Status Word  
This command is a two byte structure (High and Low bytes). The PMBusTM specification (Table 15) details the structure and  
content of the word. Note that unsupported bits shall be set to “0”  
Status Word (79h); Low Byte  
Byte  
Bit #  
PMBusTM Bit Name  
Definition  
Bit 7  
BUSY  
Not Supported  
Pulse Width Modulator enable status:  
1 = PWM disabled  
0 = PWM enabled  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
Bit 2  
OFF  
VOUT_OV  
IOUT_OC  
VIN_UV  
Output over voltage fault  
1 = OVP has occurred  
0 = OVP has not occurred  
OCP; the unit has entered overload protection.  
1= OCP has occurred  
0= OCP has not occurred  
Low  
Incoming AC under voltage:  
1 = AC is not OK  
0 = AC is OK  
Over Temperature fault  
1 = OTP has occurred  
0 = OTP has not occurred  
TEMPERATURE  
Bit 1  
Bit 0  
CML  
Not Supported  
Not Supported  
NONE OF THE ABOVE  
Status Word; High Byte  
Byte  
Bit #  
Bit 7  
Bit 6  
Bit 5  
Bit 4  
Bit 3  
PMBusTM Bit Name  
VOUT  
Definition  
Voltage Fault or Warning uVP fault only  
Not Supported  
IOUT/POUT  
INPUT  
Not Supported  
MFR  
Auxiliary Specific Failure  
Not Supported  
POWER_GOOD#  
High  
Fan Failure  
1 = Fan has failed  
0 = Fan has not failed  
Bit 2  
FAN  
Bit 1  
Bit 0  
OTHER  
Not Supported  
Not Supported  
UNKNOWN  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSA-1100 DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY  
date 07/15/2015 page 10 of 11  
DEMO BOARD  
Accessories  
Description  
Demo Board1  
CUI Part Number  
01T-156801-1  
Vendor/Part Number  
DC Output Mating Connector  
I2C dongle2  
AC power cord3  
22P-S00065-4  
TEConn 2-1926739-5  
Microchip DV164122  
Qualtek 312019-01  
Notes:  
1. This demo board is intended for user connection to evaluate the power supply in the laboratory by qualified personnel. Please take necessary safety precautions during  
product evaluation.  
2. The PICkit Serial Analyzer is an USB-based tool used to direct communication between a PC and an external serial device. The kit comes complete with hardware  
(supporting I2C™, SMBus, SPI and USART protocols), an easy-to-use GUI (to configure and display communications) and a target demonstration board for out-of-the-box  
functionality. http://www.microchip.com/stellent/idcplg?IdcService=SS_GET_PAGE&nodeId=1406&dDocName=en028600  
3. For North American use only  
Demo Board Power Connections  
Demo Board Connections/Settings  
J1  
J2  
J6  
J7  
+12V Output  
P1  
P2  
DC Output Mating Connector  
12V Return  
Control & Status Signals  
+ Standby Output  
Standby Output Return  
1
2
3
4
5
6
Logical Return  
Remote ON (override by P7)  
Present  
AC_OK  
DC_OK  
NC  
P3  
I2C Dongle Connection  
1
2
3
4
5
6
SMB  
SCL  
SDA  
Logical Return  
VDD  
NC  
Jumper to Local Sense+, remove jumper  
for remote sense  
P4  
P5  
P6  
P7  
Jumper to Local Sense-, remove jumper  
for remote sense  
Jumper to Select 5V Standby, remove  
jumper to set 3.3V Standby  
Jumper to ON, remove jumper for  
Remote ON/OFF  
Jumper to set I2C A0 = 0, remove jumper  
to set address by host  
P8  
P9  
Control & Status Signals  
1
2
3
4
5
6
NC  
NC  
NC  
ISHARE (optional force sharing)  
SENSE+ (override by P4)  
SENSE- (override by P5)  
cui.com  
For more information, please visit the product page.  
CUI Inc SERIES: PSA-1100 DESCRIPTION: AC-DC HOT-SWAP POWER SUPPLY  
date 07/15/2015 page 11 of 11  
REVISION HISTORY  
rev.  
description  
date  
1.0  
initial release  
05/07/2015  
07/15/2015  
1.01  
updated datasheet  
The revision history provided is for informational purposes only and is believed to be accurate.  
Headquarters  
20050 SW 112th Ave.  
Tualatin, OR 97062  
800.275.4899  
Fax 503.612.2383  
cui.com  
techsupport@cui.com  
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.  
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is  
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.  
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a  
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.  

相关型号:

PSA-1100-12-B5

AC-DC HOT-SWAP POWER SUPPLY
CUI

PSA-1100-12-F

Front-End Power Supply, 12 Vdc, 92 A, 1100 W
CUI

PSA-1100_15

AC-DC HOT-SWAP POWER SUPPLY
CUI

PSA-12

Fixed Attenuator, 0MHz Min, 12400MHz Max, ROHS COMPLIANT PACKAGE-2
APITECH

PSA-12024

AC/DC CONVERTER 24V 120W
ALTECH

PSA-124

Single Output Adaptor Switching Power Supply
PHIHONG

PSA-12E

Power Supplies (12 Volt)
ETC

PSA-13

Fixed Attenuator, 0MHz Min, 12400MHz Max, ROHS COMPLIANT PACKAGE-2
APITECH

PSA-14

RF/Microwave Attenuator, 0 MHz - 12400 MHz RF/MICROWAVE FIXED ATTENUATOR, ROHS COMPLIANT PACKAGE-2
AEROFLEX

PSA-15

Fixed Attenuator, 0MHz Min, 12400MHz Max, ROHS COMPLIANT PACKAGE-2
APITECH

PSA-15

RF/Microwave Attenuator, 0 MHz - 12400 MHz RF/MICROWAVE FIXED ATTENUATOR, ROHS COMPLIANT PACKAGE-2
AEROFLEX

PSA-15-201

Dual Output Adaptor
PHIHONG