SERIES: PDM1-S │ DESCRIPTION: DC-DC CONVERTER
FEATURES
• 1 W isolated output
• smaller package
• single/dual unregulated output
• 1,500 Vdc isolation
• continuous short circuit protection
• extended temperature range (-40~105°C)
• antistatic protection up to 8kV
• high efficiency at light load
• efficiency up to 82%
input
voltage
output
voltage
output
current
output
power
max
ripple
efficiency
MODEL
and noise1
typ
range
min
max
typ
typ
(Vdc)
(Vdc)
(Vdc)
5
(mA)
(mA)
200
83
(W)
(mVp-p)
(%)
PDM1-S5-S5-S
5
4.5~5.5
20
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
30
30
60
60
30
30
60
60
30
30
60
30
30
60
30
60
30
60
30
30
60
30
30
60
80
80
81
81
80
80
81
81
80
80
81
80
81
81
80
81
80
81
79
81
82
80
81
79
PDM1-S5-S12-S
PDM1-S5-S15-S
PDM1-S5-S24-S
PDM1-S5-D5-S
5
4.5~5.5
12
5
4.5~5.5
15
7
67
5
4.5~5.5
24
5
42
5
4.5~5.5
±5
±12
±15
±24
5
±10
±5
±4
±2
20
9
±100
±42
±33
±21
200
83
PDM1-S5-D12-S
PDM1-S5-D15-S
PDM1-S5-D24-S
PDM1-S12-S5-S
PDM1-S12-S12-S
PDM1-S12-S15-S
PDM1-S12-D5-S
PDM1-S12-D12-S
PDM1-S12-D15-S
PDM1-S15-S5-S
PDM1-S15-S15-S
PDM1-S15-D5-S
PDM1-S15-D15-S
PDM1-S24-S5-S
PDM1-S24-S12-S
PDM1-S24-S15-S
PDM1-S24-D5-S
PDM1-S24-D12-S
PDM1-S24-D15-S
5
4.5~5.5
5
4.5~5.5
5
4.5~5.5
12
12
12
12
12
12
15
15
15
15
24
24
24
24
24
24
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
10.8~13.2
13.5~16.5
13.5~16.5
13.5~16.5
13.5~16.5
21.6~26.4
21.6~26.4
21.6~26.4
21.6~26.4
21.6~26.4
21.6~26.4
12
15
7
67
±5
±12
±15
5
±10
±5
±4
20
7
±100
±42
±33
200
67
15
±5
±15
5
±10
±4
20
9
±100
±33
200
83
12
15
7
67
±5
±12
±15
±10
±5
±4
±100
±42
±33
Notes:
1. ripple and noise are measured at 20 MHz BW by “parallel cable” method
cui.com
CUI Inc │ SERIES: PDM1-S │ DESCRIPTION: DC-DC CONVERTER
date 03/18/2013 │ page 2 of 6
PART NUMBER KEY
PDM1 - SXX - XXX -S
Base Number
Packaging Style
SIP
Output
S = single
D = dual
Output Voltage
Input Voltage
INPUT
parameter
conditions/description
min
typ
max
units
5 V input models
12 V input models
15 V input models
24 V input models
4.5
5
5.5
Vdc
Vdc
Vdc
Vdc
10.8
13.5
21.6
12
15
24
13.2
16.5
26.4
operating input voltage
for maximum of 1 second
5 V input models
12 V input models
15 V input models
24 V input models
-0.7
-0.7
-0.7
-0.7
9
Vdc
Vdc
Vdc
Vdc
surge voltage
18
21
30
filter
capacitance filter
OUTPUT
parameter
conditions/description
for Vin change of 1%
min
typ
max
±1.2
15
units
%
line regulation
load regulation
voltage accuracy
voltage balance
switching frequency
temperature coefficient
measured from 10% load to full load
see tolerance envelope curve
dual output, balanced loads
100% load, nominal input voltage
100% load
%
±0.5
100
±1
300
%
kHz
±0.03
%/°C
PROTECTIONS
parameter
conditions/description
min
typ
typ
max
max
units
short circuit protection
continuous, automatic recovery
SAFETY AND COMPLIANCE
parameter
conditions/description
min
units
Vdc
isolation voltage
isolation resistance
conducted emissions
for 1 minute at 1 mA max.
at 500 Vdc
1,500
1,000
MΩ
CISPR22/EN55022 class B (external circuit required)
IEC/EN61000-4-2, class B, contact ± 8kV for single outputs
IEC/EN61000-4-2, class B, contact ± 6kV for dual outputs
ESD
MTBF
as per MIL-HDBK-217F @ 25°C
yes
3,500,000
hours
RoHS compliant
ENVIRONMENTAL
parameter
conditions/description
min
-40
-55
typ
max
105
125
95
units
°C
operating temperature
storage temperature
storage humidity
see derating curve
°C
non-condensing
at full load
%
temperature rise
25
°C
cui.com
CUI Inc │ SERIES: PDM1-S │ DESCRIPTION: DC-DC CONVERTER
date 03/18/2013 │ page 3 of 6
SOLDERABILITY
parameter
conditions/description
min
typ
max
300
260
units
°C
hand soldering
wave soldering
1.5 mm from case for 10 seconds
see wave soldering profile
°C
Peak Temp. 260°C Max.
Wave Soldering Time
250
4 Sec. Max.
200
150
100
10 Sec. Max.
50
0
Time (sec.)
MECHANICAL
parameter
dimensions
conditions/description
min
typ
max
units
19.50 x 6.00 x 9.00 (0.768 x 0.236 x 0.200 inch)
epoxy resin (UL94-V0)
mm
case material
weight
2.4
g
MECHANICAL DRAWING
units: mm[inch]
tolerance: ±0.25[±0.010]
pin section tolerance: ±0.10[±0.004]
ꢁꢂꢃꢄꢀfꢀꢃꢄꢀ
>ꢀꢃꢇꢈꢅfꢀꢃꢀꢆꢀ@
ꢁ
ꢆ
ꢋ
ꢄ
ꢈ
ꢀꢃꢈꢀfꢀꢃꢁꢀ
>ꢀꢃꢀꢆꢋfꢀꢃꢀꢀꢋ@
ꢇꢃꢈꢆ
>ꢀꢃꢉꢀꢀ@
ꢁꢆꢃꢇꢀ
>ꢀꢃꢄꢀꢀ@
Front View
ꢆꢃꢁꢉ>ꢀꢃꢀꢅꢋ@
Bottom View
Side View
ꢆꢃꢁꢉ
>ꢀꢃꢀꢅꢋ@
∅
ꢁꢃꢀꢀ>ꢀꢃꢀꢋꢀ@
PIN CONNECTIONS
PIN
1
Single Output
Dual Output
ꢁ
ꢆ
ꢋ
ꢄ
ꢈ
Vin
GND
0V
Vin
GND
-Vo
2
ꢇꢃꢈꢆ
4
>ꢀꢃꢉꢀꢀ@
ꢁꢆꢃꢇꢀ
>ꢀꢃꢄꢀꢀ@
Grid Size: 2.54mm x 2.54mm
5
No Pin
+Vo
0V
6
+Vo
PCB Layout
Top View
cui.com
CUI Inc │ SERIES: PDM1-S │ DESCRIPTION: DC-DC CONVERTER
date 03/18/2013 │ page 4 of 6
DERATING CURVES
Tolerance Envelope Curve
Temperature Derating Curve
10
7.5
5
100
80
2.5
2.5
0
Rated Output Voltage
-2.5
60
-2.5
Safe operating area
40
20
-5
-7.5
-7.5
-10
10
20
30
40
50
60
70
80
90
100
Output Current Percentage (%)
(Nominal Input Voltage)
-40
-20
0
20
40
60
85
105 120
Ambient Temperature (°C)
EMC RECOMMENDED CIRCUIT
LDM
Recommended external circuit components
Vin
(Vdc)
Vin
Vin
+Vo
C1
LDM
C2
EUT
LOAD
C1
5
4.7μF/50V
4.7μF/50V
4.7μF/50V
4.7μF/50V
6.8μH
6.8μH
6.8μH
6.8μH
NC
12
NC
GND
GND
-Vo
(0V)
15
470pF/2kV
470pF/2kV
24
C2
TEST CONFIGURATION
Oscilloscope
Lin
External components
Lin
4.7μH
Current
Probe
Load
Cin
DC
DC
220μF, ESR < 1.0Ω
Cin
at 100 KHz
Note: Input reflected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance.
cui.com
CUI Inc │ SERIES: PDM1-S │ DESCRIPTION: DC-DC CONVERTER
date 03/18/2013 │ page 5 of 6
APPLICATION NOTES
1. Output load requirement
To ensure this module can operate efficiently and reliably, the minimum output load may not be less than 10% of the full load during
operation. If the actual output power is low, connect a resistor at the output end in parallel to increase the load.
2. Overload Protection
Under normal operating conditions, the output circuit of this product has no protection against overload. The simplest method to add
this is to add a circuit breaker to the circuit.
3. Recommended circuit
If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low
ESR(see Figure 1). However, the capacitance of the output filter capacitor must be appropriate. If the capacitance is too high, a
startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the maximum capacitance must
be less than the maximum capacitive load (see Table 1).
Single Output
+Vo
Vin
GND
Cout
Cin
DC DC
0V
Figure 1
Dual Output
Vin
+Vo
0V
Cout
Cout
Cin
DC
DC
GND
Vo
Vin
(Vdc)
Cin
(µF)
Single Vo
(Vdc)
Cout
(µF)
Dual Vo
(Vdc)
Cout
(µF)
5
4.7
2.2
2.2
1
5
10
2.2
1
±5
4.7
1
Table 1
12
12
15
24
±12
±15
±24
15
0.47
0.47
24
1
It’s not recommended to connect any external capacitors in applications with less than 0.5 watt output.
4. Output Voltage Regulation and Over-voltage Protection Circuit
The device for output voltage regulation, over-voltage and over-current protection is a linear regulator and a capacitor filtering net-
work with overheat protection, which can be connected to the input or output end in series (see Figure 2). The recommended capaci-
tance of its filter capacitor (see Table 1), and the linear regulator is based on the actual voltage and current required.
Single Output
+Vo
0V
REG
Vin
REG
DC DC
DC DC
GND
Figure 2
Dual Output
+Vo
0V
REG
REG
Vin
REG
GND
-Vo
Note:
1. Operation under minimum load will not damage the converter; however, they may not meet all specifications listed.
2. Max. capacitive load tested at input voltage range and full load.
3. All specifications measured at: Ta=25°C, humidity<75%, nominal input voltage and rated output load, unless otherwise specified.
cui.com
CUI Inc │ SERIES: PDM1-S │ DESCRIPTION: DC-DC CONVERTER
date 03/18/2013 │ page 6 of 6
REVISION HISTORY
rev.
description
initial release
date
1.0
03/18/2013
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明