GF0506 [CUI]
SPEAKER;型号: | GF0506 |
厂家: | CUI INC |
描述: | SPEAKER |
文件: | 总3页 (文件大小:180K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
For more information, please visit the product page.
date 07/03/2012
page 1 of 3
MODEL: GF0506 │ DESCRIPTION: SPEAKER
RoHS
SPECIFICATIONS
parameter
nominal size
impedance
conditions/description
min
typ
max
units
mm
Ω
50
at 0.8 kHz, 1 V
6.8
344
79
8
9.2
516
85
resonant frequency
sound pressure level
response
at 1 V
430
82
Hz
0.25 W, 50 cm ave., at 1, 1.4, 1.7, 2 kHz
10 dB max.
dB
Fo
7,200
0.5
Hz
input power
operation
0.25
0.25
1.41
W
must be normal at program source
must be normal at sine wave
size: 32 x 18 x 6 mm
W
buzz, rattle, etc.
magnet
Vdc
load test
24 hours of white noise at
20 ~ 50% RH for 24 hours
90 ~ 95% RH for 24 hours
yes
0.25
70
W
°C
°C
heat test
68
38
72
42
humidity test
RoHS
40
FREQUENCY RESPONSE CURVE
parameter
conditions/description
potentiometer range
rectifier
50 dB
RMS
lower limit frequency
wr. speed
20 Hz
100 mm/sec
60 dB
zero level
cui.com
For more information, please visit the product page.
CUI Inc │ MODEL: GF0506 │ DESCRIPTION: SPEAKER
date 07/03/2012 │ page 2 of 3
MECHANICAL DRAWING
units: mm
tolerance: ±0.5 mm
45.00
32.00
17.50
2.50
50.00
4.00
(4 PLCS)
+
-
56.50
cui.com
For more information, please visit the product page.
CUI Inc │ MODEL: GF0506 │ DESCRIPTION: SPEAKER
date 07/03/2012 │ page 3 of 3
REVISION HISTORY
rev.
description
date
1.0
initial release
03/04/2009
new template applied, height changed from 18 to 17.5 mm,
resonant frequency, and SPL changed
1.01
07/03/2012
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.
相关型号: