EPSA240100U-P5P-SZ [CUI]
AC/DC WALL MOUNT ADAPTER 24V 24W;型号: | EPSA240100U-P5P-SZ |
厂家: | CUI INC |
描述: | AC/DC WALL MOUNT ADAPTER 24V 24W |
文件: | 总5页 (文件大小:487K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Additional Resources: Product Page
date 12/10/2014
page 1 of 5
SERIES: EPSA 24W │ DESCRIPTION: AC-DC POWER SUPPLY
FEATURES
• up to 24 W power
• universal input (90~264 Vac)
• single regulated output from 12~24 V
• short circuit protections
• UL/cUL safety approvals
• level V efficiency
• custom designs available
RoHS
output
voltage
output
current
max
output
ower
ax
ripple
efficiency
MODEL
and noise1
level
max
(Vdc)
12
(A)
(
(mVp-p)
EPSA120200U
EPSA150160U
EPSA240100U
2
1.6
1
24
24
24
150
150
240
V
V
V
15
24
Notes:
1. At full load, 100 ~ 240 Vac input, 20 MHz bandwidth oscilloscope, each outt terminated with 10 µF aluminum electrolytic and 0.1 µF ceramic capacitors.
PART NUMBER KEY
E0200U - XX - SZ - CXX
Be Numbr
Reserved for Custom
emple of 12 Vdc,
Configurations
DC Plug Type
Factory
Designation
cui.com
Additional Resources: Product Page
CUI Inc │SERIES: EPSA 24W │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/10/2014 │ page 2 of 5
INPUT
parameter
voltage
conditions/description
min
90
typ
max
264
63
units
frequency
current
47
0.8
at 115 Vac, full load, cold start
at 230 Vac, full load, cold start
50
100
inrush current1
leakage current
0.2
.3
mA
W
no load power consumption
Notes:
1. 24 V model, no damage at 230 Vac, cool start
OUTPUT
parameter
conditions/description
mi
typ
±
±5
max
units
%
line regulation
load regulation
%
PROTECTIONS
parameter
conditions/description
short circuit protection
output shut down and auto restart
SAFETY & COMPLIANCE
parameter
conditions/description
min
typ
max
units
3,000
4,242
Vac
Vdc
isolation voltage
input to output at 10 mA for 1 mnute
isolation resistance
safety approvals
EMI/EMC
input to output at 50Vdc
UL 60950-1
100
MΩ
FCC Class B
RoHS compliant
yes
ENVIRONMENTAL
parameter
conditions/on
min
0
typ
max
40
units
°C
operating temperature
storage temperature
operating humidity
storage humidity
-10
20
70
°C
80
%
10
90
%
cui.com
Additional Resources: Product Page
CUI Inc │SERIES: EPSA 24W │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/10/2014 │ page 3 of 5
MECHANICAL
parameter
conditions/description
3.150 x 2.110 x 1.378 (80 x 53.6 x 35 mm)
fixed US
min
typ
max
units
dimensions
input plug
MECHANICAL DRAWING
units: mm
DC CORD
cable length
ijIJƲĴ
ijįĹſĵįıŮŮ
59C
ŔıIJ
ĸıƲIJı
Ŕħŕ
MODEL NO.
EPSA120200U
EPSA150160U1
EPSA240100U1
CABLE GAUGE
20 AWG
CORD LENGTH
1,530 mm ±100
1,530 mm ±100
1,530 mm ±100
20 AWG
22 AWG
Note:
1. “P5P” models have 1,830 mm ± 100 cord length
cui.com
Additional Resources: Product Page
CUI Inc │SERIES: EPSA 24W │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/10/2014 │ page 4 of 5
OUTPUT PLUG OPTIONS
3.5 mm Phono Plug
14 0.5
14 0.5
*Tip positive
P1
P1R
Standard DC Plug
A
B
C
Unit
mm
mm
mm
mm
mm
C
C
P5
5.5
5.5
3.5
8
3.8
2.1
9.5
9.5
9.5
9.5
9.5
P6/P
P7/P7R
8/P8R
P9/R
2.5
1.35
1.35
1.05
Standard PX
Right Angle PXR
Locking DC Plug
C
A
B
C
Unit
mm
mm
P10
P11
5.5
5.5
2.1
2.5
9.5
9.5
EIAJ Plugs
C
EIAJ
A
B
C
D
Unit
P12/P12R EIAJ-1 2.35 0.7 9.5 NA mm
P13/P13R EIAJ-2 4.0 1.7 9.5 5.0 mm
P14/P14R EIAJ-3 4.75 1.7 9.5 5.0 mm
C
tandarPXX
Right Angle PXXR
D
Striped and Tinned
25 5
9 2
PLUG TYPE
ST
PXX X X
Stripped and Tinned
Plug Type
Plug Angle:
Plug Polarity:
“Blank” = Standard “Blank” = N/A
R = Right Angle
P = Center Positive
N = Center Negative
*Contact CUI for additional output plug options.
cui.com
Additional Resources: Product Page
CUI Inc │SERIES: EPSA 24W │ DESCRIPTION: AC-DC POWER SUPPLY
date 12/10/2014 │ page 5 of 5
REVISION HISTORY
rev.
description
date
1.0
initial release
updated output plug options
02/01/2010
06/21/010
07/6/2011
0127/202
03/15012
8/21/22
05/5/2013
12/12014
1.01
1.02
1.03
1.04
1.05
1.06
1.07
updated inrush current, protection data, and output plug options
new template applied
updated P7/P7R B dimension
V-Infinity branding removed, EMI/EMC data updated
CE data removed
updated datasheet
The revision history provided is for informational purposes only and is believto be acrate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
This mplies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This vice may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical
component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to
affect its safety or effectiveness.