CEB-44D06 [CUI]
piezo electric diaphragm; 压电隔膜型号: | CEB-44D06 |
厂家: | CUI INC |
描述: | piezo electric diaphragm |
文件: | 总4页 (文件大小:284K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Date: 7/28/2006
Unit: mm
Part No: CEB-44D06
Description: piezo electric diaphragm
Page No: 1 of 4
Specifications
Maximum input voltage
Resonant frequency
Resonant impedance
Electrostatic capacitance
Operating temperature
Storage temperature
Dimensions
20 Vp-p
0.6 ± 0.3 KHz
1000 Ω max.
70,000 ±30% pF
-20 ~ +70° C
-30 ~ +80° C
ø44.0 x H0.23 mm
5.10 g max.
Brass
see Measurement Methods
see Measurement Methods
at 120 Hz / 1 V
Weight
Material
Terminal
Wire type
DC resistance
20 M Ω min.
Fluke 45 rate: Fast
Measurement time: 1 second
(only for ≤ 20 mm test)
RoHS
yes
Appearance Drawing
Tolerance: ±0.5
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Date: 7/28/2006
Unit: mm
Part No: CEB-44D06
Description: piezo electric diaphragm
Page No: 2 of 4
Measuring Methods
1) Resonant frequency / Resonant impedance
The piezo electric diaphragm should be clamped at a node point (as shown in the following figure) to be free from any
mechanical stress. Measure its resonant frequency and resonant impedance by using a vector impedance analyzer or
equivalent.
When the input frequency is swept within 100 Hz to 3 KHz, the resonant frequency is defined as the frequency where
the impedance shows minimum value. This impedance should be the resonant impedance.
2) Static capacitance
The electrostatic capacitance should be measured at 120 Hz by using an L.C.R. meter (ex. HP4194A(H.P.)) or
equivalent. The part should be clamped in the same way as the measurement or resonant frequency / resonant
impedance mentioned above.
Mechanical Characteristics
Item
Test Condition
Evaluation Standard
Solderability
(Connector excepted)
Stripped wires of lead wires are immersed in
rosin for 5 seconds and then immersed in
solder bath of 270 ±5°C for 3 ±0.5 seconds.
The horizontal force of 3.0N (0.306kg) should
be applied to the double lead wire for 30 sec.
The diaphragm should be measured after
applying a vibration amplitude of 1.5 mm with
90% min. of the stripped wires
will be wet with solder. (Except
the edge of the terminal)
No damage or cutting off.
Lead Wire Pull Strength
Vibration
The value of the resonant
frequency should be ±10% of the
10 to 55 Hz band of vibration frequency to each initial measurements.
of the 3 perpendicular directions for 2 hours.
Electrostatic capacitance should
be ±20% compared with the initial
measurement. The SPL should
be within ±10dB compared
with the initial measurement.
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Date: 7/28/2006
Unit: mm
Part No: CEB-44D06
Description: piezo electric diaphragm
Page No: 3 of 4
Environment Test
Item
Test Condition
Evaluation Standard
High temp. test
After being placed in a chamber at +80°C for
240 hours.
Low temp. test
Humidity test
After being placed in a chamber at -30°C for
240 hours.
After being placed in a chamber at +40°C and
90±5% relative humidity for 240 hours.
The part shall be subjected to 5 cycles. One
cycle will consist of:
The diaphragm will be measured
after being placed at +25°C for 4
hours. The value of the
resonant frequency should be
±10%, the value of the electro
static capacitance should be
±20% compared to the initial
measurements. The resonant
impedance should be 2,000 Ω
max.
Temp. cycle test
Test Conditions
Standard Test Condition
Judgement Test Condition
a) Tempurature: +5 ~ +35°C
a) Tempurature: +25 ±2°C
b) Humidity: 45 - 85%
b) Humidity: 60 - 70%
c) Pressure: 860-1060 mbar
c) Pressure: 860-1060 mbar
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Date: 7/28/2006
Unit: mm
Part No: CEB-44D06
Description: piezo electric diaphragm
Page No: 4 of 4
Packaging
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062