AE10-UW-S5 [CUI]
DC-DC CONVERTER;型号: | AE10-UW-S5 |
厂家: | CUI INC |
描述: | DC-DC CONVERTER DC-DC转换器 |
文件: | 总6页 (文件大小:676K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
For more information, please visit the product page.
date 03/05/2018
page 1 of 6
SERIES: AE10-UW │ DESCRIPTION: DC-DC CONVERTER
FEATURES
• 10 watts
• high operating temp -40 to +70°C
• 4,000 Vac isolation
• designed to meet UL 1741; EN 62109 approved
• board mounted
• input voltage range of 200~1,500 Vdc
• low ripple & noise
• OVP protection
• output short circuit protection
input
voltage
range
output
voltage
output
current
output
power
max
ripple
efficiency2
MODEL
& noise1
min
max
max
typ
(Vdc)
(Vdc)
5
(A)
(A)
(W)
(mVp-p)
(%)
AE10-UW-S5
200~1500
0
2.0
10
300
64
Notes:
1. Measured at nominal input, 20 MHz bandwidth oscilloscope, with 10 µF electrolytic and 1 µF ceramic capacitors on the output.
2. Measured at 800 Vdc input voltage, full load.
3. All specifications are measured at Ta=25°C, humidity < 75%, nominal input voltage, and rated output load unless otherwise specified.
PART NUMBER KEY
AE10-UW - SXX
Base Number
Output Voltage
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: AE10-UW │ DESCRIPTION: DC-DC CONVERTER
date 03/05/2018 │ page 2 of 6
INPUT
parameter
conditions/description
min
typ
max
units
operating input voltage
200
1500
Vdc
shut-down range
turn-on range
170
180
185
195
Vdc
Vdc
under voltage shutdown
at 200 Vdc
at 800 Vdc
at 1500 Vdc
120
30
16
mA
mA
mA
current
at 200 Vdc
at 800 Vdc
at 1500 Vdc
30
80
150
A
A
A
inrush current
input fuse
15 A / 1500 Vdc (external)
OUTPUT
parameter
conditions/description
min
typ
max
units
μF
maximum capacitive load
voltage accuracy
line regulation
6,000
±2
±1
±1
%
from low line to high line, full load
from 0% to full load
%
load regulation
%
delay time
from Vin = 0 V to 90% of rated ouptut voltage
2
s
switching frequency
temperature coefficient
65
kHz
%/°C
at full load
±0.02
PROTECTIONS
parameter
conditions/description
min
typ
typ
max
8
units
Vdc
%
over voltage protection
over current protection
short circuit protection
automatic recovery
120
320
continuous, automatic recovery
SAFETY AND COMPLIANCE
parameter
conditions/description
min
max
units
isolation voltage
safety approvals
conducted emissions
radiated emissions
ESD
input to output for 1 minute
CSA, EN 62109
4,000
Vac
CISPR22/EN55022, class A (external circuit required, see Figure 2)
CISPR22/EN55022, class A (external circuit required, see Figure 2)
IEC/EN61000-4-2, contact ± 6kV/air ± 8kV, class B
IEC/EN61000-4-3, 10V/m, class A
radiated immunity
EFT/burst
IEC/EN61000-4-4, ± 2kV, class B (external circuit required, see Figure 2)
IEC/EN61000-4-5, line-line ± 1kV, class B (external circuit required, see Figure 2)
IEC/EN61000-4-6, 10 Vr.m.s, class A
surge
conducted immunity
magnetic field immunity
MTBF
IEC/EN61000-4-8, 10 A/m, class A
as per MIL-HDBK-217F, 25°C
2011/65/EU
300,000
hours
RoHS
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: AE10-UW │ DESCRIPTION: DC-DC CONVERTER
date 03/05/2018 │ page 3 of 6
ENVIRONMENTAL
parameter
conditions/description
min
-40
-40
typ
max
70
units
°C
operating temperature
storage temperature
storage humidity
altitude
see derating curves
85
°C
non-condensing
95
%
see derating curves
5000
m
SOLDERABILITY
parameter
conditions/description
for 3~5 seconds
min
350
255
typ
360
260
max
370
265
units
°C
hand soldering
wave soldering
for 5~10 seconds
°C
MECHANICAL
parameter
dimensions
conditions/description
min
typ
max
units
125.00 x 75.00 x 40.00 [4.921 x 2.953 x 1.575 inch]
black flame-retardant heat-proof plastic (UL94V-0)
mm
case material
weight
300
g
MECHANICAL DRAWING
units: mm [inch]
tolerance: ±0.50[±0.020]
pin diameter tolerance: ±0.10[±0.004]
pin height tolerance: ±1.50[±0.059]
In high vibration environments, this series
should be mounted with screws.
tightening torque: max 0.4 N*m
PIN CONNECTIONS
PIN
1
Function
-Vin
2
+Vin
3
NC
4
-Vout
+Vout
5
NC=no connection
Recommended PCB Layout
Top View
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: AE10-UW │ DESCRIPTION: DC-DC CONVERTER
date 03/05/2018 │ page 4 of 6
DERATING CURVES
Temperature Derating Curve
(200~300 Vdc input voltage)
Temperature Derating Curve
(300~1500 Vdc input voltage)
100
100
80
70
60
80
70
60
40
20
0
40
20
0
-40
-20
0
20
40 50 60 70 80
-40
-20
0
20
40 50 60 70 80
Ambient Temperature (°C)
Ambient Temperature (°C)
Load vs. Input Voltage Derating Curve
(at 25°C)
Load vs. Altitude Derating Curve
100
80
100
80
60
40
20
0
60
40
20
0
200
1500
0
2000
5000
Input Voltage (Vdc)
Altitude (m)
EFFICIENCY CURVES
Efficiency Curve
Efficiency vs. Input Voltage
Efficiency Curve
Efficiency vs. Load Current
85
80
82
80
78
76
74
72
70
68
75
70
65
60
55
50
66
64
200
400
600
800 1000 1200 1400 1500
10 20 30 40 50 60 70 80 90 100
Load Current (%)
Input Voltage (Vdc)
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: AE10-UW │ DESCRIPTION: DC-DC CONVERTER
date 03/05/2018 │ page 5 of 6
APPLICATION CIRCUIT
Figure 1
FU S E
C 1 C 2
R L
TV S
+ I N P U T
-IN P UT
+ V in
+Vo
+
D C -D C
-Vo
-V in
Table 1
Vout
(Vdc)
C1
(μF)
C2
(μF)
Fuse
15 A / 1500 Vdc
TVS
SMBJ7.0A
5
1
120
EMC RECOMMENDED CIRCUIT
Figure 2
Table 2
Recommended External Circuit Components
F US E
LD M
C 7
C 8
C 9
LC M
FUSE
C7, C8, C9, C10
C3, C4, C5, C6
R1, R2, R3, R4
LDM
15 A/1500 Vdc
104K/275 Vac
47 µF/450 Vdc
1 MΩ/2 W
C 1 C 2
RL
TVS
+INP U T
-IN P U T
+Vi n
-Vin
+Vo
C 3
C 4
C 5
C 6
R1
R2
R3
R4
D C - D C
C 10
-Vo
330 µH/1 A
7 mH/1 A
LCM
Note: See also Table 1.
Notes:
1. C1 is a ceramic capacitor used to filter high frequency noise.
2. C2 is electrolytic and is recommended to be high frequency and low resistance. For capacitance and current of the capacitor, refer to the datasheet provided by the
manufacturer. Capacitance withstand voltage derating should be 80% or above.
cui.com
For more information, please visit the product page.
CUI Inc │ SERIES: AE10-UW │ DESCRIPTION: DC-DC CONVERTER
date 03/05/2018 │ page 6 of 6
REVISION HISTORY
rev.
description
date
1.0
initial release
09/13/2017
03/05/2018
1.01
updated datasheet
The revision history provided is for informational purposes only and is believed to be accurate.
Headquarters
20050 SW 112th Ave.
Tualatin, OR 97062
800.275.4899
Fax 503.612.2383
cui.com
techsupport@cui.com
CUI offers a two (2) year limited warranty. Complete warranty information is listed on our website.
CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is
assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use.
CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a
life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
相关型号:
©2020 ICPDF网 联系我们和版权申明