12V 18 W  
HR 1218W  
HR 1218W is specially designed for high efficient  
discharge application. Its characteristics are high energy  
density, small footprint and high discharge efficiency. It can  
be used for more than 260 cycles at 100% discharge in cycle  
service, up to 5 years in standby service.  
Specification  
Cells Per Unit  
Voltage Per Unit  
Capacity  
6
12  
18W @ 15min-rate to 1.67V per cell @25 (77  
)
Weight  
Approx. 1.53 kg (3.37 lbs)  
130A(F2)(5sec)  
Maximum Discharge Current  
Internal Resistance  
Approx. 27.8m  
TUV Asia Pacific Ltd.  
Taiwan Branch  
Operating Temperature Range  
Discharge: -15 ~50 ( 5 ~122  
Charge: -15 ~40 ( 5 ~104  
Storage: -15 ~40 ( 5 ~104  
)
)
)
Nominal Operating Temperature Range  
Float Charging Voltage  
25  
3
(77  
5 )  
TUV Asia Pacific Ltd.  
Taiwan Branch  
13.5 to 13.8 VDC/unit Average at 25 (77  
1.8A  
)
)
Recommended Maximum Charging  
Current Limit  
Equalization and Cycle Service  
Self Discharge  
14.4 to 15.0 VDC/unit Average at 25 (77  
CSB-manufactured VRLA  
(Absorbent Glass Mat type)  
batteries are UL-recognized  
components under UL1989.  
CSB Batteries can be stored for more than 6 months at  
25 (77 ). Please charge batteries before using. For  
higher temperatures the time interval will be shorter.  
F2-Faston Tab250  
Terminal  
CSB is also certified by  
Container Material  
ABS(UL 94-HB) & Flammability resistance of  
(UL 94-V0) can be available upon request.  
ISO 9001 and ISO 14001.  
Dimensions :  
Unit: mm (inch)  
Overall Height (H)  
98.3±1.0 (3.87±0.04)  
Container height (h)  
94.0±1.0 (3.70±0.04) 151.0±2.0(5.94±0.08) 51.0±1.0 (2.01±0.04)  
Length (L)  
Width (W)  
(http://www.csb-battery.com)  
Thesystem of manufacturer was certified  
by TUVCERTaccording to ISO9001,ISO14001.  
Constant Current Discharge Characteristics Unit:A (25 ,77  
)
F.V/Time  
1.60V  
1.67V  
1.70V  
1.75V  
1.80V  
1.85V  
2MIN  
4MIN  
26.5  
24.8  
24.1  
22.8  
20.6  
18.3  
6MIN  
20.2  
19.6  
19.2  
18.1  
16.6  
14.9  
8MIN  
16.3  
15.9  
15.5  
15.0  
14.1  
12.6  
10MIN 15MIN 20MIN 30MIN 60MIN 90MIN  
33.2  
30.9  
30.0  
29.2  
27.9  
24.1  
13.6  
13.3  
13.0  
12.7  
12.0  
10.9  
9.86  
9.74  
9.59  
9.46  
9.11  
8.43  
7.77  
7.74  
7.67  
7.53  
7.32  
6.82  
5.61  
5.54  
5.47  
5.42  
5.32  
5.04  
3.17  
3.12  
3.10  
3.07  
3.04  
2.92  
2.28  
2.24  
2.22  
2.20  
2.17  
2.09  
Constant Power Discharge Characteristics Unit:W (25 ,77  
)
F.V/Time  
1.60V  
1.67V  
1.70V  
1.75V  
1.80V  
1.85V  
2MIN  
339  
332  
329  
325  
308  
273  
4MIN  
271  
260  
252  
241  
227  
207  
6MIN  
213  
206  
202  
194  
183  
170  
8MIN  
178  
174  
172  
165  
155  
143  
10MIN 15MIN 20MIN 30MIN 60MIN 90MIN  
150  
147  
146  
141  
133  
124  
108  
107  
106  
105  
102  
94.6  
88.0  
87.0  
85.8  
85.0  
82.5  
77.9  
64.5  
64.2  
63.5  
62.9  
61.8  
59.2  
37.0  
36.8  
36.4  
36.0  
35.6  
34.4  
26.7  
26.5  
26.2  
26.0  
25.7  
24.8  
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.  
RA : 1604  
12V 18W  
HR 1218W  
140  
120  
100  
80  
0.049  
0.042  
0.035  
0.028  
0.021  
0.014  
0.007  
2.60  
2.40  
2.20  
2.00  
1.80  
1.60  
1.40  
)Ratio  
1PWx15Min  
1PWx7.5Min  
60  
40  
20  
0.025PA  
0
3
6
9
12  
15  
18  
140  
120  
100  
80  
0.049  
0.042  
0.035  
0.028  
0.021  
0.014  
0.007  
2.60  
2.40  
2.20  
2.00  
1.80  
1.60  
1.40  
68  
)Ratio  
1PWx15Min  
1PWx7.5Min  
60  
40  
14.70V  
2.45V  
20  
0.025PA  
0
3
6
9
12  
15  
18  
Charging Procedures  
Charge Voltage(V/Cell)  
Final Discharge  
Voltage V/Cell  
Discharge  
Application  
Max.Charge Current  
0.1PA  
1.75  
1.70  
1.60  
1.30  
Temperature  
Set Point  
2.45  
Allowable Range  
2.40~2.50  
25 (77  
25 (77  
)
)
Cycle Use  
Standby  
0.1P (W)<0.25P  
0.25P (W)<1.0P  
(W) 1.0P  
0.1P>(W)  
2.275  
2.25~2.30  
Power(W)  
GLOBAL HQ  
AMERICA HQ  
EUROPE HQ  
CSB BATTERY CO., LTD. (TAIWAN)  
CSB BATTERY TECHNOLOGIES INC. (U.S.A)  
Tel : +1-817-244-7777/1-(800)3-CSB-USA(272872)  
Fax : +1-817-244-4445  
CSB Battery Europe BV.  
Tel : +886-2-2880-5600  
Fax : +886-2-2888-3300  
mail : service@csb-battery.com.tw  
Tel : +31(0)-180-418-140  
Fax : +31(0)-180-418-327  
mail : eurosales@csb-battery.eu  
mail : csb@csb-battery.com  
SHANGHAI OFFICE. (CHINA)  
CSB BATTERY LOGISTIC (SHANGHAI) CO., LTD.  
Tel : +86-21-5046-1622/5046-0833  
Fax : +86-21-5064-1046  
BEIJING OFFICE. (CHINA)  
SHENZHEN OFFICE.( CHINA )  
CSB BATTERY LOGISTIC ( SHANGHAI ) CO., LTD.  
Tel : +86-755-8831-6488/6396/6356  
Fax : +86-755-8831-6548  
C
SB BATTERY TECHNOLOGIES (BEIJING) CO., LTD.  
Tel : +86-10-5820-5336/5338  
Fax : +86-10-58203053  
mail : chinasls@csb-battery.com  
mail : chinasls@csb-battery.com  
mail : she@csb-battery.com.cn  

相关型号:

HR1218W_17

Valve Regulated Lead Acid Battery
CSB-BATTERY

HR122-2812

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

HR122-2812

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

HR122-2815

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

HR122-28L15

2-OUTPUT 12W DC-DC REG PWR SUPPLY MODULE, 0.325 INCH HEIGHT, HERMETIC SEALED, METAL, PACKAGE-8
CRANE

HR1221W

specially designed for high efficient discharge application
CSB-BATTERY

HR1221W_16

specially designed for high efficient discharge application
CSB-BATTERY

HR1221W_17

Valve Regulated Lead Acid Battery
CSB-BATTERY

HR1224W

specially designed for high efficient discharge application
CSB-BATTERY

HR1224W_16

Cells Per Unit 6 Voltage Per Unit 12
CSB-BATTERY

HR1224W_17

Valve Regulated Lead Acid Battery
CSB-BATTERY

HR1227W

specially designed for high efficient discharge application
CSB-BATTERY