GP12400_16 [CSB-BATTERY]

Cells Per Unit 6 Voltage Per Unit 12;
GP12400_16
型号: GP12400_16
厂家: CSB BATTERY CO., LTD.    CSB BATTERY CO., LTD.
描述:

Cells Per Unit 6 Voltage Per Unit 12

文件: 总2页 (文件大小:749K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Powered by  
12V 40Ah  
GP 12400 is a general purpose battery up to 5 years in standby  
service or more than 260 cycles at 100% discharge in cycle  
service. As with all CSB batteries, all are rechargeable, highly  
efficient, leak proof and maintenance free.  
GP 12400  
Specification  
Cells Per Unit  
6
Voltage Per Unit  
Capacity  
12  
40A h @ 20hr-rate to 1.75V per cell @25°C (77°F)  
Approx. 12.63 kg(27.84 lbs)  
400A(5sec)  
Weight  
Maximum Discharge Current  
Internal Resistance  
Operating Temperature Range  
Approx. 8.5mΩ  
Discharge:  
-15°C~50°C( 5°F~122°F)  
-15°C~40°C( 5°F~104°F)  
-15°C~40°C( 5°F~104°F)  
TUV Asia Pacific Ltd.  
Taiwan Branch  
Charge:  
Storage:  
Nominal Operating Temperature Range  
Float Charging Voltage  
25°C±3°C (77°F±5°F)  
13.5 to 13.8 VDC/unit Average at 25°C (77°F)  
12A  
TUV Asia Pacific Ltd.  
Taiwan Branch  
Recommended Maximum Charging  
Current Limit  
Equalization and Cycle Service  
Self Discharge  
14.4 to 15.0 VDC/unit Average at 25°C (77°F)  
CSB-manufactured VRLA  
(Absorbent Glass Mat type)  
batteries are UL-recognized  
components under UL1989.  
CSB Batteries can be stored for more than 6 months at  
25°C(77°F). Please charge batteries before using. For  
higher temperatures the time interval will be shorter.  
Terminal  
Container Material  
B8-L terminal (M5 bolt) or Recessed type (M6 bolt)  
ABS(UL 94-HB) & Flammability resistance of  
(UL 94-V0) can be available upon request.  
CSB is also certified by  
ISO 9001 and ISO 14001.  
Dimensions :  
Unit: mm (inch)  
Overall Height (H)  
170±2 (6.69±0.08)  
Container height (h)  
170±2 (6.69±0.08)  
Length (L)  
197±2 (7.76±0.08)  
Width (W)  
165±2 (6.5±0.08)  
Drawing of recessed terminal  
B8  
(http://www.csb-battery.com)  
The system of manufacturer was certified  
by TUV CERT according to ISO 9001,ISO 14001.  
Constant Current Discharge Characteristics Unit:A (25°C,77°F)  
F.V/Time  
1.60V  
1.67V  
1.70V  
1.75V  
1.80V  
1.85V  
5MIN  
176  
157  
149  
135  
121  
107  
10MIN 15MIN 30MIN 60MIN 90MIN  
2HR  
17.7  
17.6  
17.5  
17.4  
17.3  
17.2  
3HR  
12.6  
12.5  
12.4  
12.3  
12.2  
12.1  
5HR  
8.01  
7.98  
7.96  
7.93  
7.88  
7.85  
8HR  
5.25  
5.19  
5.17  
5.10  
5.03  
4.96  
10HR  
4.28  
4.19  
4.16  
4.09  
4.03  
3.96  
20HR  
2.21  
2.11  
2.08  
2.00  
1.93  
1.85  
113  
105  
101  
95.0  
88.3  
81.7  
85.0  
81.0  
78.7  
75.5  
71.7  
67.8  
51.8  
50.8  
50.1  
49.0  
47.6  
46.2  
30.6  
30.3  
30.2  
30.0  
29.8  
29.4  
22.2  
22.1  
21.9  
21.8  
21.7  
21.5  
Constant Power Discharge Characteristics Unit:W(25°,77°F)  
F.V/Time  
1.60V  
1.67V  
1.70V  
1.75V  
1.80V  
1.85V  
5MIN  
2110  
1886  
1790  
1620  
1450  
1280  
10MIN  
1350  
1259  
1214  
1140  
1060  
980  
15MIN  
1020  
972  
30MIN  
622  
606  
600  
585  
571  
555  
60MIN  
367  
364  
363  
360  
357  
353  
90MIN  
266  
264  
263  
262  
260  
258  
2HR  
212  
211  
210  
209  
208  
207  
3HR  
151  
150  
149  
148  
147  
146  
5HR  
96.1  
95.7  
95.5  
95.2  
94.8  
94.2  
8HR  
63.0  
62.3  
62.0  
61.2  
60.4  
59.6  
10HR  
51.3  
50.4  
50.0  
49.2  
48.3  
47.5  
20HR  
26.5  
25.4  
24.9  
24.1  
23.2  
22.4  
945  
902  
860  
814  
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.  
RA1507  
12V 40Ah  
GP12400  
140  
120  
100  
80  
0.20  
0.17  
0.14  
0.11  
0.08  
0.05  
0.02  
2.60  
2.40  
2.20  
2.00  
1.80  
1.60  
1.40  
)Ratio  
60  
40  
13.65V  
(2.275V/Cell)  
20  
0
4
8
12  
16  
20  
24  
140  
120  
100  
80  
0.20  
0.17  
0.14  
0.11  
0.08  
0.05  
0.02  
2.60  
2.40  
2.20  
2.00  
1.80  
1.60  
1.40  
68  
)Ratio  
60  
40  
20  
0
4
8
12  
16  
20  
24  
Charge Voltage(V/Cell)  
Final Discharge  
Voltage V/Cell  
Discharge  
Application  
Max.Charge Current  
0.3C  
1.75  
1.70  
1.60  
1.30  
Temperature  
Set Point  
2.45  
Allowable Range  
2.40~2.50  
25 (77  
25 (77  
)
)
Cycle Use  
Standby  
0.2C>(A)  
0.2C<(A)<0.5C  
0.5C<(A)<1.0C  
(A)>1.0C  
2.275  
2.25~2.30  
Current(A)  
GLOBAL HQ  
AMERICA HQ  
CSB BATTERY TECHNOLOGIES INC. (U.S.A)  
Tel : +1-817-244-7777/1-(800)3-CSB-USA(272872)  
Fax : +1-817-244-4445  
EUROPE HQ  
CSB BATTERY CO., LTD. (TAIWAN)  
CSB Battery Europe BV.  
Tel : +31(0)-180-418-140  
Fax : +31(0)-180-418-327  
Tel : +886-2-2880-5600  
Fax : +886-2-2888-3300  
mail : service@csb-battery.com.tw  
mail : csb@csb-battery.com  
mail : eurosales@csb-battery.eu  
SHANGHAI OFFICE. (CHINA)  
CSB BATTERY LOGISTIC (SHANGHAI) CO., LTD.  
Tel : +86-21-5046-1622/5046-0833  
Fax : +86-21-5064-1046  
BEIJING OFFICE. (CHINA)  
SHENZHEN OFFICE.( CHINA )  
CSB BATTERY LOGISTIC ( SHANGHAI ) CO., LTD.  
Tel : +86-755-8831-6488/6396/6356  
Fax : +86-755-8831-6548  
C
SB BATTERY TECHNOLOGIES (BEIJING) CO., LTD.  
Tel : +86-10-5820-5336/5338  
Fax : +86-10-58203053  
mail : chinasls@csb-battery.com  
mail : chinasls@csb-battery.com  
mail : she@csb-battery.com.cn  

相关型号:

GP12400_17

Valve Regulated Lead Acid Battery
CSB-BATTERY

GP1245

general purpose battery up to 5
CSB-BATTERY

GP1245_16

Cells Per Unit 6 Voltage Per Unit 12
CSB-BATTERY

GP1245_17

Valve Regulated Lead Acid Battery
CSB-BATTERY

GP1250

HIGH VOLTAGE DIODE RECTIFIERS
DEC

GP12650

general purpose battery up to 5
CSB-BATTERY

GP12650_16

Cells Per Unit 6 Voltage Per Unit 12
CSB-BATTERY

GP12650_17

Valve Regulated Lead Acid Battery
CSB-BATTERY

GP1272

Valve Regulated Lead Acid Battery
CSB-BATTERY

GP12MABE

Sealed Ultraminiature Pushbutton Switches
ITT

GP12MAKE

Switch, SPDT, Horizontal, Through Hole-right Angle,
ITT

GP12MCBE

Sealed Ultraminiature Pushbutton Switches
ITT