MHF2812D [CRANE]

DC/DC CONVERTERS 28 VOLT INPUT; DC / DC转换器, 28伏特的输入
MHF2812D
型号: MHF2812D
厂家: Crane Aerospace & Electronics.    Crane Aerospace & Electronics.
描述:

DC/DC CONVERTERS 28 VOLT INPUT
DC / DC转换器, 28伏特的输入

转换器 输入元件
文件: 总6页 (文件大小:88K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
FEATURES  
• –55° to +125°C operation  
MHF SERIES  
12 WATT  
DC/DC CONVERTERS  
• 16 to 40 VDC input  
(19 to 40 VDC for 15 volt outputs)  
• Fully Isolated  
28 VOLT  
INPUT  
MODELS  
• Optocoupler feedback  
VDC OUTPUT  
• Fixed frequency 600 kHz typical  
• Forward converter topology  
• 50 V for up to 50 ms transient protection  
• Inhibit function  
SINGLE  
DUAL  
±12  
5
12  
15  
±15  
• Indefinite short circuit protection  
3
• Up to 83% efficiency, 22 W/in  
Size (max.): 1.460 x 1.130 x 0.330 inches (37.08 x 28.70 x 8.38 mm)  
See Section B8, case E1 for dimensions.  
Weight:  
Screening: Standard or ES.  
See section C2 for screening options.  
21 grams typical.  
DESCRIPTION  
elements on both the input and output to help reduce the need for  
external components. For information about filtering to meet MIL-  
STD-461’s CE03 test, contact your Interpoint representative.  
The MHF Series™ of DC/DC converters offer up to 12 watts of  
power from single or dual outputs in a single package over a the full  
military temperature range. Thick film hybrid manufacturing tech-  
nology produces high levels of miniaturization, giving the MHF  
Series converters a low profile (0.330 inch), small board area (1.65  
WIDE VOLTAGE RANGE  
3
square inches), and high power density (22 watt/in ).  
The MHF Series is designed to provide full power operation over the  
input voltage range of 16 to 40 volts. The 15 volt models provide a  
19 to 40 volt range. Operation below 16 volts (or 19 volts for the 15  
volt models), including operation in MIL-STD-704E emergency  
power conditions, is possible with derated output power. Please  
refer to the low line drop-out graphs, Figures 9 and 10.  
The parts are packaged in hermetically sealed steel enclosures,  
making them ideal for use in military, aerospace, and high reliability  
industrial applications.  
DESIGN METHODOLOGY  
The MHF converters are switching regulators which use a quasi-  
square wave, single ended forward converter design with a nominal  
switching frequency of 600 kHz. Isolation between input and output  
circuits is provided with a transformer in the forward power loop and  
a temperature insensitive optical link in the feedback control loop.  
Output regulation is accomplished with constant frequency pulse  
width modulation. Both line and load regulation are typically within  
10 mV.  
MILITARY TEMPERATURE RANGE  
The MHF Series provides full power operation at case temperatures  
from –55°C up to +125°C. All 12 and 15 volt models in both single  
and dual output configurations provide full power operation at  
+125°C with derated power to 135°C. The +5 volt model provides  
full power at 110°C derated to 0% at 130°C. Depending on operating  
levels, air flow, and ambient temperature; heat sinking may be  
required.  
On dual output models, the positive output is independently regu-  
lated and the negative output is cross-regulated. Figures 7 and 8  
illustrate what effects load changes have on the negative output.  
INHIBIT FEATURE  
An inhibit terminal is provided that can be used to disable internal  
switching, resulting in a very low quiescent input current. An open  
collector TTL compatible low (0.8V) is required to control the inhibit  
function. This level may be supplied by an open collector gate since  
the inhibit pin is provided with an internal pull-up resistor.  
Indefinite short circuit protection and overload protection are  
provided by sensing output load current and restricting the output  
current to approximately 125% of full load output current. Since the  
output current is sensed in the secondary stage, the result is a  
predictable, constant output current control with no foldback char-  
acteristics. MHF converters are provided with internal filtering  
B2-77  
MHF SERIES  
12 WATT  
DC/DC CONVERTERS  
INHIBIT  
TYPICAL CHARACTERISTICS  
ABSOLUTE MAXIMUM RATINGS  
Input Voltage  
Inhibit TTL Open Collector  
• Logic low (output disabled)  
Logic low 0.8 V max  
Inhibit pin current 4 mA max  
• Referenced to input common  
• Logic high (output enabled)  
Open collector  
Output Voltage Temperature Coefficient  
• 150 ppm/°C, typical  
Input to Output Capacitance  
• 50 pF, typical  
Current Limit  
• 125% of full load, typical  
Isolation  
• 100 megohm minimum at 500 V  
Conversion Frequency  
• 600 kHz typical  
• 16 to 40 VDC (19 to 40 VDC 15 volt output)  
Output Power  
• 12 watts (10 watts MHF2805S)  
Lead Soldering Temperature (10 sec per lead)  
• 300°C  
Storage Temperature Range (Case)  
• –55°C to +135°C  
RECOMMENDED OPERATING CONDITIONS  
Inhibit Pin Voltage (unit enabled)  
• 8 to 11 V  
Input Voltage Range  
• 16 to 40 VDC continuous  
• 19 to 40 VDC 15 volt outputs continuous  
• 50 V for 50 msec transient  
Case Operating Temperature (Tc)  
• –55°C to +125°C full power  
• –55°C to +110°C full power for MHF2805S  
• –55°C to +135°C absolute  
• –55°C to +130°C absolute for MHF2805S  
Derating Output Power/Current  
• Linearly from 100% at 125°C to 0% at 135°C  
• Linearly from 100% at 110°C to 0% at 130°C  
for MHF2805S  
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.  
SINGLE OUTPUT MODELS  
PARAMETER  
MHF2805S  
MHF2812S  
TYP MAX  
MHF2815S  
MIN TYP MAX  
CONDITIONS  
MIN  
4.95  
TYP  
5.0  
MAX  
MIN  
11.88  
UNITS  
VDC  
A
OUTPUT VOLTAGE  
OUTPUT CURRENT  
OUTPUT POWER  
OUTPUT RIPPLE  
5.05  
2.0  
10  
60  
50  
50  
40  
50  
30  
483  
3
12  
30  
10  
10  
28  
20  
2
12.12  
1.0  
12  
14.85  
15  
25  
10  
10  
28  
20  
2
15.15  
0.8  
12  
MIN. TO MAX. V  
W
IN  
10 kHz to 2 MHz  
MIN. TO MAX. V  
40  
10  
10  
28  
60  
50  
mV p-p  
mV  
LINE REGULATION  
LOAD REGULATION  
INPUT VOLTAGE  
50  
50  
IN  
NO LOAD TO FULL  
CONTINUOUS  
TRANSIENT 50 ms  
NO LOAD  
50  
50  
mV  
16  
16  
40  
19  
40  
VDC  
V
50  
50  
INPUT CURRENT  
20  
30  
30  
FULL LOAD  
557  
3
535  
3
mA  
INHIBITED  
2
INPUT RIPPLE  
CURRENT  
10 kHz TO 2 MHz  
135  
77  
180  
150  
81  
200  
150  
83  
220  
mA p-p  
%
EFFICIENCY  
74  
77  
80  
1
LOAD FAULT  
POWER DISSIPATION  
OVERLOAD  
5
80  
5
5
2
W
SHORT CIRCUIT  
DELAY  
3.5  
300  
2.8  
200  
START-UP  
Notes  
180  
150  
250  
ms  
1. Indefinite short circuit protection not guaranteed above 125°C case temperature (110°C case for MHF2805S).  
B2-78  
MHF SERIES  
12 WATT  
DC/DC CONVERTERS  
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.  
DUAL OUTPUT MODELS  
PARAMETER  
MHF2812D  
TYP  
MHF2815D  
TYP  
CONDITION  
MIN  
11.88  
11.82  
MAX  
12.12  
12.18  
1.0  
MIN  
14.85  
14.77  
MAX  
15.15  
15.23  
0.8  
UNITS  
OUTPUT VOLTAGE  
+V  
12.0  
12.0  
0.5  
15.0  
15.0  
0.4  
OUT  
VDC  
– V  
OUT  
1, 2  
OUTPUT CURRENT  
A
2
OUTPUT POWER  
+V  
10.8  
10.8  
12  
10.8  
10.8  
12  
OUT  
– V  
W
OUT  
TOTAL  
OUTPUT RIPPLE  
VOLTAGE  
10 kHz TO 2 MHz  
30  
5
60  
50  
30  
5
60  
50  
mV p-p  
mV  
LINE REGULATION  
MIN. TO MAX. V  
IN  
+V  
OUT  
LOAD REGULATION  
NO LOAD TO FULL  
CROSS REGULATION  
+V  
16  
5
5
50  
10  
5
19  
10  
4
50  
8
mV  
%
OUT  
3
20% TO 80% LOAD  
4
50% LOAD  
4
3
5
INPUT VOLTAGE  
NO LOAD TO FULL  
INPUT CURRENT  
CONTINUOUS  
28  
40  
50  
28  
40  
50  
VDC  
V
TRANSIENT 50 ms  
NO LOAD  
FULL LOAD  
INHIBITED  
25  
35  
550  
3
25  
35  
536  
3
mA  
1.9  
1.9  
INPUT RIPPLE  
CURRENT  
10 kHz TO 2 MHz  
175  
81  
240  
175  
83  
240  
mA p-p  
%
EFFICIENCY  
78  
80  
5
LOAD FAULT  
POWER DISSIPATION  
SHORT CIRCUIT  
OVERLOAD  
2.8  
5
2
5
W
START-UP  
DELAY  
150  
250  
150  
250  
ms  
Notes  
1. Applies to both outputs.  
4. 50% load on the positive output and 50% to 20% load on the negative output.  
2. Maximum combined output power is 12 watts. A maximum of 90% is avail-  
able from either output.  
50% load on the negative output and 50% to 20% load on the positive output.  
See Figure 7.  
3. 20% to 80% load on the positive output and 80% to 20% on the negative  
output. See Figure 8.  
5. Indefinite short circuit protection not guaranteed above 125°C case temper-  
ature.  
PIN OUT  
Squared corner and dot on  
top of cover indicate pin one.  
MODEL NUMBER KEY  
Pin  
1
Single Output  
Inhibit  
Dual Output  
Inhibit  
MHF 28 12 D / ES  
Base Model  
2
No connection  
Positive Output  
Input Voltage  
3
Output Common Output Common  
Output Voltage  
1
8
2
3
4
5
6
4
Positive Output  
No connection  
Case Ground  
Input Common  
Positive Input  
Negative Output  
No connection  
Case Ground  
Input Common  
Positive Input  
Number of Outputs  
(S = single, D = dual)  
5
BOTTOM VIEW  
MHF  
6
Screening  
(Standard screening has no designator  
in this position.)  
7
8
7
See Section B8, case E1, for dimensions.  
FIGURE 1: PIN OUT  
B2-79  
MHF SERIES  
12 WATT  
DC/DC CONVERTERS  
Typical Performance Curves: 25°C Tc , 28 VDC Vin, 100% load, unless otherwise specified.  
90  
80  
70  
60  
50  
90  
80  
70  
60  
50  
90  
80  
70  
60  
50  
16V  
19V  
16V  
40V  
40V  
28V  
40V  
28V  
28V  
10  
2
4
6
8
10 12 14  
2
6
8
12  
14  
4
2
4
6
8
10 12 14  
Output Power (Watts)  
MHF2805S Efficiency  
FIGURE 2  
Output Power (Watts)  
MHF2812S Efficiency  
FIGURE 3  
Output Power (Watts)  
MHF2815S Efficiency  
FIGURE 4  
90  
80  
70  
60  
50  
90  
80  
70  
60  
50  
10  
8
19V  
16V  
6
Cond. A  
2812D  
4
40V  
40V  
2
0
2815D  
28V  
28V  
2
–4  
–6  
–8  
–10  
2812D  
Cond. B  
2
4
6
8
10 12 14  
0
10  
2
30  
40  
50  
2
4
6
8
10 12 14  
Output Power (Watts)  
Output Load (%)  
Output Power (Watts)  
Condition A: 50% Load Pos. Vout, 50% to 20% Neg. Vout  
Condition B: 50% Load Neg. Vout, 50% to 20% Pos. Vout  
MHF Negative Output Voltage  
MHF2815D Efficiency  
MHF2812D Efficiency  
Cross Regulation  
FIGURE 6  
FIGURE 5  
FIGURE 7  
20  
15  
19  
18  
17  
16  
15  
14  
13  
12  
11  
19  
18  
2815S  
10  
17  
2815D  
16  
5
0
15  
14  
2815D  
2812S  
2805S  
–5  
2812D  
–10  
–15  
–20  
13  
2812D  
12  
11  
0
20  
40  
60  
80  
100  
2
4
6
8
10 12 14  
2
4
6
8
10 12 14  
Output Load (%)  
Output Power (Watts)  
50 mV Drop  
Output Power (Watts)  
50 mV Drop  
Positive Output 20% to 80% Load  
Negative Output 80% to 20% Load  
MHF Single Low Line Dropout  
MHF Dual Low Line Dropout  
MHF Dual Negative Output Voltage  
Cross Regulation  
FIGURE 8  
FIGURE 9  
FIGURE 10  
218211-001-DTS Rev A  
DQ# 1011  
All technical information is believed to be accurate, but no responsibility is  
assumed for errors or omissions. Interpoint reserves the right to make changes in  
products or specifications without notice. MHF Series is a trademark of Interpoint.  
Copyright © 1992 - 1999 Interpoint. All rights reserved.  
B2-80  
CASE E  
CASES  
Squared corner and dot on top  
of case indicate pin one.  
Materials  
Header Cold Rolled Steel/Nickel/Gold  
Cover Kovar/Nickel  
(SMHF Series  
CASE E  
Cold Rolled Steel/Nickel/Gold)  
#52 alloy/Gold  
compression glass seal  
BOTTOM VIEW  
See Figures 16 – 18  
for pin configurations.  
Pins  
1.130 max  
(28.70)  
Case dimensions in inches (mm)  
Tolerance ±0.005 (0.13) for three decimal places  
±0.01 (0.3) for two decimal places  
unless otherwise specified  
1.460 max  
(37.08)  
CAUTION  
Heat from reflow or wave soldering may damage  
the device. Solder pins individually with heat  
application not exceeding 300°C for 10 seconds  
per pin.  
FIGURE 15: CASE E MAXIMUM DIMENSIONS  
BOTTOM VIEW CASE E1  
MHF+ Series Single and Dual: Screening – Standard, ES, or 883  
MHF Series and LIM5050 Module: Screening – Standard or ES  
SMHF Series Single and Dual and SLIM5050 Module:  
Screening – Space Standard, H, or K  
HR120 Series: No screening options  
Projection Weld  
Seam Seal  
Squared corner and dot on top  
of case indicate pin one.  
0.960  
(24.38)  
1
2
3
4
5
0.030 dia.  
(0.76)  
8
7
6
0.160  
(4.06)  
0.000  
FIGURE 16: CASE E1  
Note: Although every effort has been made to render the case drawings at actual size, variations in the printing process may cause some distortion. Please refer  
to the numerical dimensions for accuracy.  
B8-10  
QA SCREENING  
125°C PRODUCTS  
125°C PRODUCTS  
TEST (125°C Products)  
STANDARD  
/ES  
/883 (Class H)*  
PRE-CAP INSPECTION  
Method 2017, 2032  
yes  
yes  
yes  
TEMPERATURE CYCLE (10 times)  
Method 1010, Cond. C, -65°C to 150°C  
Method 1010, Cond. B, -55°C to 125°C  
no  
no  
no  
yes  
yes  
no  
CONSTANT ACCELERATION  
Method 2001, 3000 g  
Method 2001, 500 g  
no  
no  
no  
yes  
yes  
no  
BURN-IN  
Method 1015, 160 hours at 125°C  
96 hours at 125°C case (typical)  
no  
no  
no  
yes  
yes  
no  
FINAL ELECTRICAL TEST MIL-PRF-38534, Group A  
Subgroups 1 through 6: -55°C, +25°C, +125°C  
Subgroups 1 and 4: +25°C case  
no  
yes  
no  
yes  
yes  
no  
HERMETICITY TESTING  
Fine Leak, Method 1014, Cond. A  
Gross Leak, Method 1014, Cond. C  
Gross Leak, Dip (1 x 10 )  
no  
no  
yes  
yes  
yes  
no  
yes  
yes  
no  
-3  
FINAL VISUAL INSPECTION  
Method 2009  
yes  
yes  
yes  
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.  
*883 products are built with element evaluated components and are 100% tested and guaranteed over  
the full military temperature range of –55°C to +125°C.  
Applies to the following products  
MOR Series  
MFLHP Series  
MFL Series  
MHP Series  
MTR Series  
MQO Series**  
MHD Series  
MHV Series  
MHF+ Series  
MHF Series**  
MGA Series  
MSA Series  
MGH Series  
MCH Series  
FM-704A EMI Filter  
FMD**/FME EMI Filter  
FMC EMI Filter  
FMH EMI Filter  
FMGA EMI Filter  
FMSA EMI Filter  
HUM Modules**  
LCM Modules**  
LIM Modules  
**MFLHP Series, MQO Series, MHF Series, FMD EMI Filters, Hum Modules, and LCM Modules do not offer  
‘883” screening.  
C2-10  

相关型号:

MHF2812D/ES

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

MHF2812DF/883

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

MHF2812S

Only 0.33 inches (8.38 mm) high in a hermetically sealed case
CRANE

MHF2812S

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

MHF2812S/ES

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

MHF2812SF/883

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

MHF2815D

Only 0.33 inches (8.38 mm) high in a hermetically sealed case
CRANE

MHF2815D

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

MHF2815D/ES

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

MHF2815DF/883

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

MHF2815S

Only 0.33 inches (8.38 mm) high in a hermetically sealed case
CRANE

MHF2815S

DC/DC CONVERTERS 28 VOLT INPUT
CRANE