HR301-2812 [CRANE]

DC/DC CONVERTERS 28 VOLT INPUT; DC / DC转换器, 28伏特的输入
HR301-2812
型号: HR301-2812
厂家: Crane Aerospace & Electronics.    Crane Aerospace & Electronics.
描述:

DC/DC CONVERTERS 28 VOLT INPUT
DC / DC转换器, 28伏特的输入

转换器 输入元件
文件: 总7页 (文件大小:152K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
FEATURES  
• –40° to +85°C operation  
• 18 to 36 VDC input  
(19 to 36 VDC input HR301-2805)  
• Fully Isolated  
HR300 SERIES  
30 WATT  
DC/DC CONVERTERS  
28 VOLT  
INPUT  
MODELS  
• Optocoupler feedback  
VDC OUTPUT  
• Fixed frequency, 240 to 300 kHz typical  
Topology – Push-Pull Forward  
• 50 V for up to 50 ms transient protection  
• Inhibit function  
SINGLE  
DUAL  
±12  
5
12  
15  
±15  
• Indefinite short circuit protection  
• Remote sense on HR301-2805 model  
• Up to 86% efficiency  
Size (max.): 2.720 x 1.350 x 0.505 inches (69.09 x 34.29 x 12.83 mm)  
See Section B8, case J5, for dimensions.  
Weight:  
60 grams max.  
Screening: Standard only. See Section C2 for screening description.  
Short circuit protection is provided through foldback current limiting.  
When the output current reaches approximately 125% of the full  
rated load, the output voltage begins to reduce to protect the  
converter. The converter can sustain a true short circuit condition  
indefinitely. The HR300’s flanged case facilitates removal of heat  
and provides for mechanically secure mounting. If full power opera-  
tion or indefinite short circuit protection is a system requirement, the  
HR300 converter should be mounted with an efficient heat sink in  
contact with the mounting flange.  
DESCRIPTION  
HR300 Series™ DC/DC converters combine the small size and high  
reliability of hybrid-based components, the high efficiency of  
switching regulators, and the isolation, regulation, and low noise  
characteristics of linear regulators.  
SMALL SIZE AND RELIABILITY  
HR300 DC/DC converters use thick-film hybrid manufacturing tech-  
niques for smaller size, lighter weight and higher reliability than  
converters produced with other circuit techniques. With a footprint of  
less than 3.7 square inches and a 0.5 inch height, the HR300  
converters reach power densities up to 22 watts per cubic inch.  
Internal filters in all HR300 converters provide low noise on both  
the input and outputs. On HR301 models, two-section  
L-C filters limit output ripple voltage and reflected input ripple  
current. On HR302 models, single-section L-C filters perform the  
same function.  
The HR300 parts use the same manufacturing procedures and  
quality controls that Interpoint applies to converters built for aero-  
space and military applications. The converters are hermetically  
sealed in metal packages that are guaranteed a maximum leak rate  
For maximum output regulation, the HR301-2805 is provided with  
external output voltage remote sense pins. Connecting the remote  
sense pins to the load provides a four-terminal voltage mode which  
eliminates the adverse effects of line resistance voltage drops.  
Remote sense pins may be left unconnected, but see cautions in  
this data sheet. For normal operation, remote sense pins should be  
connected to the respective output pins.  
-3  
of less than 10 atm-cc/sec.  
HIGH PERFORMANCE  
HR300 converters use a constant frequency pulse-width modulated  
switching regulator design operating in the forward mode with a  
clock switching frequency of 240 to 300 kHz. Isolation is achieved  
through the use of a transformer in the forward power circuit and an  
optocoupler in the feedback control loop. The full load output power  
of 30 watts is available over the entire 18 to 36 VDC input range (19  
to 36 HR301-2805). On dual output models, up to 90% of full power  
is available from either output up to a combined total of 30 watts.  
INHIBIT FUNCTION  
An inhibit is provided to allow a logic input to shut down the  
converter. An open circuit on the inhibit pin (pin 2 or 8) allows normal  
operation. A connection between the inhibit pin and the input  
common (pin 10) disables the internal oscillator, shutting down the  
output. The inhibit pin has an open circuit voltage of 11 to 16 V on  
single output models, 8 to 12 V on HR302-2812 and 10 to 14 V on  
HR302-2815. In the inhibit mode, approximately 1 mA must be sunk  
from the inhibit pin. An active low open collector is required to acti-  
vate the inhibit function.  
The HR300’s high efficiency is maintained over the entire input  
voltage range and from approximately 25% of full load to full load  
(see typical efficiency curves).  
B4-39  
HR300 SERIES  
DC/DC CONVERTERS  
30 WATT  
INHIBIT  
TYPICAL CHARACTERISTICS  
ABSOLUTE MAXIMUM RATINGS  
Inhibit TTL Open Collector  
• Logic low (output disabled)  
Inhibit pin current 1 mA typical  
• Referenced to input common  
• Logic high (output enabled)  
Open collector  
Input Voltage  
• 18 to 36 VDC (19 to 36 VDC HR301-2805)  
Output Power  
• 30 watts  
Lead Soldering Temperature (10 sec per lead)  
• 300°C  
Storage Temperature Range (Case)  
• –55°C to +125°C  
Output Voltage Temperature Coefficient  
• 100 ppm/°C typical  
Input to Output Capacitance  
• 80 pF typical single output models  
• 70 pF typical HR302-2812  
• 60 pF typical HR302-2815  
Current Limit  
• 125% of full load, typical  
Isolation  
• 100 megohm minimum at 500 V  
Conversion Frequency  
RECOMMENDED OPERATING CONDITIONS  
Input Voltage Range  
• 18 to 36 VDC continuous  
19 to 36 VDC HR301-2805  
• 50 V for 50 msec transient  
Case Operating Temperature (Tc)  
• –40°C to +85°C full power  
• 240 to 300 kHz  
Inhibit Pin Voltage (unit enabled)  
• 11 to 16 V single output models  
• 8 to 12 V HR302-2812  
• 10 to 14 V HR302-2815  
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.  
SINGLE OUTPUT MODELS  
PARAMETER  
HR301-2805  
HR301-2812  
TYP MAX  
HR301-2815  
TYP MAX  
CONDITIONS  
MIN  
4.95  
TYP  
5.0  
30  
7
MAX  
MIN  
11.88  
MIN  
14.85  
UNITS  
VDC  
A
OUTPUT VOLTAGE  
OUTPUT CURRENT  
OUTPUT POWER  
OUTPUT RIPPLE  
5.05  
6.0  
30.0  
60  
12  
30  
10  
10  
28  
20  
12.12  
2.5  
30.0  
70  
15  
30  
10  
10  
28  
20  
15.15  
2.0  
30.0  
75  
–40°C TO +85°C  
BW 2 MHz  
W
mV p-p  
mV  
1
LINE REGULATION  
MIN. TO MAX. V  
25  
40  
40  
IN  
2
LOAD REGULATION  
NO LOAD TO FULL  
NO LOAD TO FULL  
TRANSIENT 50 ms  
NO LOAD  
5
25  
40  
40  
mV  
INPUT VOLTAGE  
–40°C TO +85°C  
INPUT CURRENT  
19  
28  
15  
36  
18  
36  
18  
36  
VDC  
mA  
50  
50  
50  
20  
35  
35  
FULL LOAD  
1370  
15  
1400  
22  
1400  
22  
INHIBITED  
INPUT RIPPLE  
CURRENT  
BW 2 MHz  
79  
5
15  
80  
10  
84  
25  
82  
10  
86  
25  
mA p-p  
%
EFFICIENCY  
START-UP  
82  
2
DELAY  
15  
30  
40  
ms  
OVERSHOOT  
500  
1200  
1500  
mV  
Notes  
1. For HR301-2805, with the remote sense pins connected to the load and no resistance between the output pins and load.  
2. A low output impedance power source is required on the input to realize this start-up time. If less than full surge current is available, start-up time  
will be longer  
CAUTION  
Permanent damage to the HR301-2805 will result if pin 6 is shorted to ground. Damage may also result if pin 4 or pin 5 is disconnected from the load  
during operation with the remote sense leads connected to the load. If remote sense pins are not connected to the load, the output voltage of the  
HR301-2805 will rise to approximately 6.2 VDC measured across pins 4 and 5.  
B4-40  
HR300 SERIES  
30 WATT  
DC/DC CONVERTERS  
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.  
TRIPLE OUTPUT MODELS  
PARAMETER  
HR302-2812  
TYP  
HR302-2815  
CONDITION  
MIN  
11.88  
11.88  
MAX  
MIN  
14.85  
14.85  
TYP  
15.0  
15.0  
MAX  
UNITS  
OUTPUT VOLTAGE  
+V  
12.0  
12.0  
12.12  
12.12  
2.5  
15.15  
15.15  
2.0  
OUT  
VDC  
– V  
OUT  
1
OUTPUT CURRENT  
A
1
OUTPUT POWER  
–40°C to +85°C  
30.0  
30.0  
W
OUTPUT RIPPLE  
VOLTAGE  
BW 2 MHz  
50  
10  
90  
30  
50  
10  
90  
40  
mV p-p  
mV  
LINE REGULATION  
LOAD REGULATION  
V
= 18 TO 36  
IN  
NO LOAD TO FULL  
18  
20  
2.5  
2.5  
28  
60  
3.5  
3.5  
36  
18  
20  
2.2  
2.2  
28  
60  
3.2  
3.2  
36  
mV  
%
2
CROSS REGULATION  
+V  
OUT  
– V  
OUT  
INPUT VOLTAGE  
–40°C to +85°C  
INPUT CURRENT  
CONTINUOUS  
VDC  
mA  
TRANSIENT 50 ms  
50  
50  
NO LOAD  
FULL LOAD  
INHIBITED  
35  
50  
1350  
24  
45  
60  
1400  
24  
INPUT RIPPLE  
CURRENT  
BW 2 MHz  
80  
15  
84  
60  
81  
15  
85  
60  
mA p-p  
%
EFFICIENCY  
START-UP  
3
DELAY  
60  
60  
ms  
OVERSHOOT  
1500  
1500  
mV  
Notes  
1. Up to 90% of full power is available from either output providing the total power does not exceed 30 watts.  
2. The effect on the output voltage of either output (held at 3 watts) when the other output is varied from 3 to 27 watts.  
3. A low output impedance power source is required on the input to realize this start-up time. If less than full surge  
current is available, start-up time will be longer  
PIN OUT  
Squared corner and dot on  
top of cover indicate pin one.  
Pin  
1
HR301-2805  
Positive Input  
Inhibit  
Single Output  
Positive Input  
Inhibit  
Dual Output  
Positive Input  
No connection  
Positive Output  
2
3
Sense Return  
No connection  
1
2
3
4
5
6
4
Output Common Output Common Output Common  
5
Positive Output  
Positive Sense  
Case Ground  
No connection  
No connection  
Input Common  
Positive Output  
No connection  
Case Ground  
No connection  
No connection  
Input Common  
Negative Output  
No connection  
Case Ground  
Inhibit  
BOTTOM VIEW  
HR300  
6
See Section B8, case J5, for dimensions.  
7
8
10  
9
8
7
9
Input Common  
Input Common  
10  
FIGURE 1: PIN OUT  
MODEL NUMBERING KEY  
HR30  
2 - 28 12  
Base Model  
Number of Outputs  
(1 = single, 2 = dual)  
Input Voltage  
Output Voltage  
B4-41  
HR300 SERIES  
30 WATT  
DC/DC CONVERTERS  
Typical Performance Curves: 25°C Tc  
88  
86  
88  
86  
84  
82  
80  
78  
76  
74  
72  
70  
68  
88  
18 V  
86  
19 V  
84  
82  
80  
78  
76  
74  
72  
70  
68  
84  
82  
18 V  
28 V  
28 V  
28 V  
80  
36 V  
78  
36 V  
76  
36 V  
74  
72  
70  
68  
5
10 15 20 25 30  
Output Power (Watts)  
5
10 15 20 25 30  
5
10 15 20 25 30  
Output Power (Watts)  
Output Power (Watts)  
HR301-2805 Efficiency  
HR302-2812 Efficiency  
HR301-2812 Efficiency  
FIGURE 2  
FIGURE 3  
FIGURE 4  
88  
18  
17  
16  
18  
18 V  
86  
84  
82  
80  
78  
76  
74  
72  
70  
68  
28 V  
17  
16  
15  
HR302-2815  
HR301-2812  
HR302-2812  
HR301-2815  
36 V  
15  
14  
14  
5
10 15 20 25 30  
5
10 15 20 25 30  
Output Power (Watts)  
5
10 15 20 25 30  
Output Power (Watts)  
Output Power (Watts)  
HR302-2815 Efficiency  
HR301-2812 and HR301-2815  
Low Line Dropout  
HR302-2812 and HR302-2815  
Low Line Dropout  
FIGURE 5  
FIGURE 6  
FIGURE 7  
24421-009-DTS Rev A  
DQ# 2009  
All technical information is believed to be accurate, but no responsibility is assumed  
for errors or omissions. Interpoint reserves the right to make changes in products  
B4-42  
or specifications without notice. HR300 Series is  
a trademark of Interpoint.  
Copyright © 1991 - 1999 Interpoint. All rights reserved.  
CASE J  
CASES  
Dot on top of case indicates pin one  
CASE J  
BOTTOM VIEW  
See Figures 36 - 40  
for pin configuration  
1.350 max  
(34.29)  
2.720 max  
(69.09)  
Flange Thickness:  
Cases J1 and J5  
0.060 (1.52)  
Case J2  
0.073 (1.85) max  
Cases J3 and J4  
0.067 +0.005/-0.007 (1.70 +0.13/-0.8)  
Materials  
Header Case J1  
Cold Rolled Steel/Nickel/Gold  
Cases J2 - J5  
Cold Rolled Steel/Nickel/Tin  
Cover Case J1  
Kovar/Nickel  
Case J2 - J5  
Cold Rolled Steel/Nickel/Tin  
#52 alloy (all cases)  
Pins  
Case J1  
MHV Series Triple – compression glass seal  
MTR Series Triple – ceramic seal  
Cases J2 - J5  
compression glass seal  
Case dimensions in inches (mm)  
Tolerance ±0.005 (0.13) for three decimal places  
±0.01 (0.2) for two decimal places  
unless otherwise specified  
CAUTION  
Heat from reflow or wave soldering may damage  
the device. Solder pins individually with heat  
application not exceeding 300°C for 10 seconds  
per pin.  
FIGURE 35: CASE J MAXIMUM DIMENSIONS  
Note: Although every effort has been made to render the case drawings at actual size, variations in the printing process may cause some distortion. Please refer  
to the numerical dimensions for accuracy.  
B8-22  
CASE J  
CASES  
BOTTOM VIEW CASE J4 (Rev B)  
Flanged cases: Designator required in Case Option position of model number.  
FMD28-461 EMI Filter (down-leaded): Screening – Standard or ES  
Squared corner and dot on top  
of case indicate pin one.  
Solder Seal  
1.173  
(29.79  
1
2
3
0.040 dia.  
(1.02)  
0.162 dia  
(4.11)  
0.673  
(17.09)  
Solder Tip-off  
5
4
0.173  
(4.39)  
0.000  
FIGURE 39: CASE J4  
BOTTOM VIEW CASE J5 (Rev B)  
Flanged cases: Designator required in Case Option position of model number  
for MHL Series and MTO Series only.  
MHL Series, MTO Series, MTW Series: Screening – Standard or ES  
HR300 Series: no screening options  
Squared corner and dot on top  
of case indicate pin one.  
Solder Seal  
1.173  
(29.79  
1
2
9
3
8
4
7
5
6
0.040 dia.  
(1.02)  
0.162 dia  
(4.11)  
0.673  
(17.09)  
Solder Tip-off  
10  
0.173  
(4.39)  
0.000  
FIGURE 40: CASE J5 mounting hole dimension corrected to 2.150 (rev 20060626)  
®
B8-25  
QA SCREENING  
HR PRODUCTS  
HR PRODUCTS  
TEST (HR products)  
PRE-CAP INSPECTION  
Method 2017  
STANDARD  
yes  
yes  
yes  
yes  
FINAL ELECTRICAL TEST MIL-PRF-38534, Group A  
Subgroups 1 and 4: +25°C case  
HERMETICITY TESTING  
-3  
Gross Leak, Dip (1 x 10 )  
FINAL VISUAL INSPECTION  
Method 2009  
Test methods are referenced to MIL-STD-883 as determined by MIL-  
PRF-38534.  
Applies to the following products:  
HR700 Series  
HR300 Series  
HR150 Series  
HR120 Series  
HR40 Series  
C2-13  

相关型号:

HR301-2815

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

HR301-2815

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

HR301-285

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

HR302-2805

Analog IC
ETC

HR302-2812

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

HR302-2812

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

HR302-2815

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

HR302-2815

DC/DC CONVERTERS 28 VOLT INPUT
CRANE

HR302.8KVP5000PF-20+50%R6000

CAP,CERAMIC,5NF,2.8KVDC,20% -TOL,50% +TOL
VISHAY

HR302.8KVP750PF+-20%R2000H

CAP,CERAMIC,750PF,2.8KVDC,20% -TOL,20% +TOL
VISHAY

HR303.5KVP100PF+-20%R85

CAP,CERAMIC,100PF,3.5KVDC,20% -TOL,20% +TOL,N750 TC CODE,-750PPM TC
VISHAY

HR303.5KVP1500PF+-20%R2000H

CAP,CERAMIC,1.5NF,3.5KVDC,20% -TOL,20% +TOL
VISHAY