PJA300F-15-F4 [COSEL]
AC/DC CONVERTER 15V 300W;型号: | PJA300F-15-F4 |
厂家: | COSEL CO., LTD. |
描述: | AC/DC CONVERTER 15V 300W |
文件: | 总16页 (文件大小:2855K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
AC-DC Power Supplies Enclosed Type
Power
Safety
Approvals
EMI
OCP
OVP
World wide Cost
Effective
Inrush
current
limiting
Factor
Correction
PJA-series
Feature
Low Profile (PJA100F, 150F, 300F : 1U size)
EMI
Complies with FCC-B, CISPR22-B, EN55011-B, EN55022-B,
(PJA600F, 1000F, 1500F : 2U size)
VCCI-B
Wide temperature range (-20Cto +70C, Derating is required)
Harmonic attenuator (Complies with IEC61000-3-2 class A)
Universal input (AC85 - 264V, Derating is required)
Low power consumption at no load
Complies with SEMI F-47 (PJA1000F, 1500F can meet at 200V
input range only)
(PJA1500F: Class A. In conducted noise, it can meet class B
by additional EMI/EMC filter.)
EMS Compliance : EN61204-3, EN61000-6-2
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Many optional functions
Safety agency approvals
UL62368-1, C-UL (CSA62368-1), EN62368-1
UL508 (PJA100F, 150F)
Complies with DEN-AN
5-year warranty (See Instruction Manual)
CE marking
Low Voltage Directive
RoHS Directive
June 25, 2020
PJA-1
Ordering information
AC-DC Power Supplies Enclosed Type
PJ
A
100
F
-O -O
5 6
PJA100F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-04-472
R
*6
6Optional
C: with Coating
R: Remote on/off
(Required external
power source)
J : EP (Tyco Electronics)
connector type
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
J1: VH (J.S.T.)
connector type
T : Vertical terminal block
N2: with DIN rail
See 6.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
SPECIFICATIONS
*Please consider "PBA100F-5-N" about 5V output with case cover.
MODEL
PJA100F-12
AC85 - 264 1f(Output derating is required at AC85V - 115V. Refer to “Derating” and instruction manual 1.1, 3)
ACIN 100V 1.2typ (Io=90%)
PJA100F-15
PJA100F-24
PJA100F-36
PJA100F-48
VOLTAGE[V]
CURRENT[A]
ACIN 115V 1.1typ (Io=100%)
ACIN 230V 0.6typ (Io=100%)
50 / 60 (47 - 63)
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V 82typ (Io=90%)
ACIN 115V 82typ (Io=100%)
ACIN 230V 85typ (Io=100%)
ACIN 100V 0.98typ (Io=90%)
ACIN 115V 0.98typ (Io=100%)
83typ (Io=90%)
83typ (Io=100%)
86typ (Io=100%)
85typ (Io=90%)
85typ (Io=100%)
88typ (Io=100%)
86typ (Io=90%)
86typ (Io=100%)
89typ (Io=100%)
86typ (Io=90%)
86typ (Io=100%)
89typ (Io=100%)
INPUT
POWER FACTOR
ACIN 230V 0.90typ (Io=100%) *Power factor correction is stopped at AC250V or more.
ACIN 100V 16typ (Io=90%) Ta=25Cat cold start
INRUSH CURRENT[A] ACIN 115V 16typ (Io=100%) Ta=25Cat cold start
ACIN 230V 32typ (Io=100%) Ta=25Cat cold start
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.75max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)
12
15
24
36
48
ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to “Derating”)
CURRENT[A]
ACIN 115V-264V 8.4
6.7
4.3
2.8
2.1
ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to “Derating”)
WATTAGE[W]
ACIN 115V-264V 100.8
100.5
103.2
100.8
100.8
*
3
48max
LINE REGULATION[mV]
60max
120max
96max
150max
144max
150max
192max
300max
Io=30 to 100% 100max
LOAD REGULATION
*
3
[mV]
Io=0 to 30% Burst operation (Please contact us about detail)
0 to +40C 120max
-10 to 0C 160max
Io=0 to 30% 500max
0 to +40C 150max
-10 to 0C 180max
Io=0 to 30% 600max
0 to +40C 120max
-10 to +40C 180max
120max
160max
500max
150max
180max
600max
150max
180max
60max
120max
160max
500max
150max
180max
600max
240max
290max
96max
150max
200max
500max
200max
240max
600max
360max
440max
144max
150max
400max
500max
200max
500max
600max
480max
600max
192max
RIPPLE[mVp-p]
*1
Io: load factor
OUTPUT
RIPPLE NOISE[mVp-p]
*1
Io: load factor
TEMPERATURE REGULATION[mV]
*
2
48max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
500typ (ACIN 115V, Io=100%) Ta=25C
20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 10.80 to 13.20
13.50 to 16.50
15.00 to 15.60
21.60 to 26.40
24.00 to 24.96
32.40 to 39.60
36.00 to 37.44
43.20 to 52.80
48.00 to 49.92
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
12.00 to 12.48
Works over 105% of rating and recovers automatically
17.25 to 21.00 27.60 to 33.60
OVERVOLTAGE PROTECTION[V] 13.80 to 16.80
41.40 to 50.40
54.00 to 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
LED (Green)
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT RC
INPUT-FG
OUTPUT RC-FG
OUTPUT-RC
Optional (Required external power source. Option -R)
*
8
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
-20 to +70C(Refer to “Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
ISOLATION
*
*
8
8
*
4
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL62368-1, C-UL (CSA62368-1), EN62368-1, UL508 (Except option -J, -J1) Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
SAFETY AND
NOISE
REGULATIONS
*
7
June 25, 2020
PJA-2
PJA100F
SPECIFICATIONS
CASE SIZE/WEIGHT
41X97X109mm [1.61X3.82X4.29 inches] (Excluding terminal block and screw) (WXHXD) / 500g max
OTHERS
COOLING METHOD
Convection
*
5
WARRANTY WARRANTY
5 years (subject to the operating conditions)
*1 This is the result of measurement of the testing board with
capacitors of 22mF and 0.1mF placed at 150 mm from the
output terminals by a 20 MHz oscilloscope or a ripple-noise meter
equivalent to Keisoku-Giken RM103.
hour warm-up at 25C.
from input, output, and FG.
*3 Consult us about dynamic load and input response. Measure the output *
voltage by using the average mode of the tester to deal with the burst
operation at 30% load or less.
Do not use the power supply in overcurrent conditions or in unspecified
input voltage ranges. Otherwise the internal components may be
damaged.
See 1.6 of Instruction Manual for more details.
*4 Output power derating is required. Refer to “Derating”.
*5 See 4 in Instruction Manual for more details.
*
*
Parallel operation is not possible with this mode.
Sound noise may be heard from the power supply when used for
pulse load.
When the load factor is 0 - 30%, the switching power loss is
reduced by burst operation, which will cause ripple and ripple
noise to go beyond the specifications.
*6 Consult us about safety agency approvals for the models with optional functions.
*7 Consult us about other classes.
*2 Drift is the change in DC output for an eight hour period after a half-
*8 The RC terminal is added to option –R models.The RC terminal is isolated
Features
-
-
-
-
-
Compact design (Depth: 109mm 4.29inches)
High efficiency (88%typ PJA100F-24, AC230Vin, 100% load)
Low power consumption (1.5W typ AC240Vin, no load at standard model)
UL508 approved (Except option -J, -J1), and complies with SEMI F47 (see instruction manual 1.1)
Various connection interface options (vertical terminal [-T], AMP connector [-J], [-J1])
Block diagram
FUSE
250V 3.15A
INRUSH
CURRENT
LIMIT
NOISE
FILTER
RECTIFIER
AC IN 85 - 264V
FG
RC(-R)
CURRENT
SENSING
BOOSTER
INDUCTOR
EXTERNAL
SOURCE
CONTROL
RECTIFIER
AND
FILTER
CURRENT
SENSING
OVER VOLTAGE
PROTECTION
INVERTER
RECTIFIER
AND
INVERTER
DC OUT
FILTER
CONTROL
External view
The external size of –R option, –J option, –J1 option, –N2 option and –T option models is different from the standard model. See “6.
Options and Others” in Instruction Manual for more details.
2-M3
Name plate
Mounting hole
(Bottom side)
M3.5
AC(L)
Terminal cover
AC(N)
Point A
FG(
)
Output terminal(–)
Output terminal(+)
Output voltage
adjustable potentiometer
LED
2
1
CN4
Connector for
Remote ON/OFF (option)
19.5
[0.77]
76±0.5
[2.99]
12.5max
[0.49]
109
[4.29]
11.2±1.5 (potentiometer)
[0.44]
14±1.5
[0.55]
4
[0.16]
101
[3.98]
15.3±1.5 (LED)
¶ Tolerance : 1 [ 0.04]
[0.6]
¶
¶
¶
¶
¶
¶
¶
¶
Weight
PCB Material/thickness
Chassis material Aluminum
Cover material : Galvanizing steel
Dimensions in mm, [ ]=inches
Mounting torque : 0.49N m max
-
Screw tightening torque : M3.5 1.0N-m max
Connect the input FG to safety earth ground.
: 500g max
:
FR-4 / 1.6mm [0.06inches]
:
3-M3
Mounting hole
33.5
[1.32]
66.5±0.5
[2.62]
June 25, 2020
PJA-3
Ordering information
AC-DC Power Supplies Enclosed Type
PJ
A
150
F
-O -O
5 6
PJA150F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-04-472
R
*6
6Optional
C: with Coating
R: Remote on/off
(Required external
power source)
J : EP (Tyco Electronics)
connector type
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
J1: VH (J.S.T.)
connector type
T : Vertical terminal block
N2: with DIN rail
See 6.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
SPECIFICATIONS
*Please consider "PBA150F-5-N" about 5V output with case cover.
MODEL
PJA150F-12
AC85 - 264 1f(Output derating is required at AC85V - 115V. Refer to “Derating” and instruction manual 1.1, 3)
ACIN 100V 1.7typ (Io=90%)
PJA150F-15
PJA150F-24
PJA150F-36
PJA150F-48
VOLTAGE[V]
CURRENT[A]
ACIN 115V 1.6typ (Io=100%)
ACIN 230V 0.8typ (Io=100%)
50 / 60 (47 - 63)
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V 84typ (Io=90%)
ACIN 115V 84typ (Io=100%)
ACIN 230V 87typ (Io=100%)
ACIN 100V 0.98typ (Io=90%)
ACIN 115V 0.98typ (Io=100%)
84typ (Io=90%)
84typ (Io=100%)
87typ (Io=100%)
87typ (Io=90%)
87typ (Io=100%)
90typ (Io=100%)
87typ (Io=90%)
87typ (Io=100%)
90typ (Io=100%)
87typ (Io=90%)
87typ (Io=100%)
90typ (Io=100%)
INPUT
POWER FACTOR
ACIN 230V 0.93typ (Io=100%) *Power factor correction is stopped at AC250V or more.
ACIN 100V 16typ (Io=90%) Ta=25Cat cold start
INRUSH CURRENT[A] ACIN 115V 16typ (Io=100%) Ta=25Cat cold start
ACIN 230V 32typ (Io=100%) Ta=25Cat cold start
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.75max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)
12
15
24
36
48
ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to “Derating”)
10 6.4
ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to “Derating”)
CURRENT[A]
ACIN 115V-264V 12.5
4.2
3.2
WATTAGE[W]
ACIN 115V-264V 150.0
150.0
153.6
151.2
153.6
*
3
48max
LINE REGULATION[mV]
60max
120max
96max
150max
144max
150max
192max
300max
Io=30 to 100% 100max
LOAD REGULATION
*
3
[mV]
Io=0 to 30% Burst operation (Please contact us about detail)
0 to +40C 120max
-10 to 0C 160max
Io=0 to 30% 500max
0 to +40C 150max
-10 to 0C 180max
Io=0 to 30% 600max
0 to +40C 120max
-10 to +40C 180max
120max
160max
500max
150max
180max
600max
150max
180max
60max
120max
160max
500max
150max
180max
600max
240max
290max
96max
150max
200max
500max
200max
240max
600max
360max
440max
144max
150max
400max
500max
200max
500max
600max
480max
600max
192max
RIPPLE[mVp-p]
*1
Io: load factor
OUTPUT
RIPPLE NOISE[mVp-p]
*1
Io: load factor
TEMPERATURE REGULATION[mV]
*
2
48max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
500typ (ACIN 115V, Io=100%) Ta=25C
20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 10.80 to 13.20
13.50 to 16.50
15.00 to 15.60
21.60 to 26.40
24.00 to 24.96
32.40 to 39.60
36.00 to 37.44
43.20 to 52.80
48.00 to 49.92
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
12.00 to 12.48
Works over 105% of rating and recovers automatically
17.25 to 21.00 27.60 to 33.60
OVERVOLTAGE PROTECTION[V] 13.80 to 16.80
41.40 to 50.40
54.00 to 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
LED (Green)
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT RC
INPUT-FG
OUTPUT RC-FG
OUTPUT-RC
Optional (Required external power source. Option -R)
*
8
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
-20 to +70C(Refer to “Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
ISOLATION
*
*
8
8
*
4
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL62368-1, C-UL (CSA62368-1), EN62368-1, UL508 (Except option -J, -J1) Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
SAFETY AND
NOISE
REGULATIONS
*
7
June 25, 2020
PJA-4
PJA150F
SPECIFICATIONS
CASE SIZE/WEIGHT
41X97X129mm [1.61X3.82X5.08 inches] (Excluding terminal block and screw) (WXHXD) / 600g max
OTHERS
COOLING METHOD
Convection
*
5
WARRANTY WARRANTY
5 years (subject to the operating conditions)
*1 This is the result of measurement of the testing board with capacitors of
22mF and 0.1mF placed at 150 mm from the output terminals by a 20
MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken
RM103.
hour warm-up at 25C.
isolated from input, output, and FG.
Do not use the power supply in overcurrent conditions or in unspecified
*3 Consult us about dynamic load and input response. Measure the output
voltage by using the average mode of the tester to deal with the burst
operation at 30% load or less.
*
input voltage ranges. Otherwise the internal components may be
damaged.
See 1.6 of Instruction Manual for more details.
*4 Output power derating is required. Refer to “Derating”.
*
*
Parallel operation is not possible with this mode.
Sound noise may be heard from the power supply when used for
pulse load.
When the load factor is 0 - 30%, the switching power loss is reduced by *5 See 4 in Instruction Manual for more details.
burst operation, which will cause ripple and ripple noise to go beyond
the specifications.
*6 Consult us about safety agency approvals for the models with optional functions.
*7 Consult us about other classes.
*2 Drift is the change in DC output for an eight hour period after a half-
*8 The RC terminal is added to option –R models. The RC terminal is
Features
-
-
-
-
-
Compact design (Depth: 129mm 5.08inches)
High efficiency (90%typ PJA150F-24, AC230Vin, 100% load)
Low power consumption (1.5W typ AC240Vin, no load at standard model)
UL508 approved (Except option -J, -J1), and complies with SEMI F47 (see instruction manual 1.1)
Various connection interface options (vertical terminal [-T], AMP connector [-J], [-J1])
Block diagram
FUSE
250V 4A
INRUSH
CURRENT
LIMIT
NOISE
FILTER
RECTIFIER
AC IN 85 - 264V
FG
RC(-R)
CURRENT
SENSING
BOOSTER
INDUCTOR
EXTERNAL
SOURCE
CONTROL
RECTIFIER
AND
FILTER
CURRENT
SENSING
OVER VOLTAGE
PROTECTION
INVERTER
RECTIFIER
AND
INVERTER
DC OUT
FILTER
CONTROL
External view
The external size of –R option, –J option, –J1 option, –N2 option and –T option models is different from the standard model. See “6.
Options and Others” in Instruction Manual for more details.
2-M3
Name plate
Mounting hole
(Bottom side)
Point B
M3.5
AC(L)
AC(N)
Terminal cover
Point A
FG(
)
Output terminal(–)
Output terminal(+)
Output voltage
adjustable potentiometer
LED
2
1
CN4
Connector for
Remote ON/OFF (option)
19
[0.75]
96±0.5
[3.78]
12.5max
[0.49]
129
[5.08]
11.2±1.5 (potentiometer)
[0.44]
14±1.5
[0.55]
4
[0.16]
121
[4.76]
15.3±1.5 (LED)
¶ Tolerance : 1 [ 0.04]
[0.6]
¶
¶
¶
¶
¶
¶
¶
¶
Weight
PCB Material/thickness
Chassis material Aluminum
Cover material : Galvanizing steel
Dimensions in mm, [ ]=inches
Mounting torque : 0.49N m max
-
Screw tightening torque : M3.5 1.0N-m max
Connect the input FG to safety earth ground.
: 600g max
:
FR-4 / 1.6mm [0.06inches]
:
48
[1.89]
70±0.5
[2.76]
3-M3
Mounting hole
June 25, 2020
PJA-5
Ordering information
AC-DC Power Supplies Enclosed Type
PJ
A
300
F
-O -O
5 6
PJA300F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-06-472
R
*6
6Optional
C: with Coating
G: Low leakage current
V : External potentiometer for
output voltage adjustment
R : Remote on/off
(Required external power source)
F4: Low speed fan
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
See 6.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
SPECIFICATIONS
MODEL
PJA300F-5
PJA300F-12
PJA300F-15
PJA300F-24
PJA300F-36
PJA300F-48
VOLTAGE[V]
AC85 - 264 1f(Output derating is required at AC85V - 100V. Refer to “Derating” and instruction manual 1.1, 3)
ACIN 100V 3.5typ (Io=100%) 3.9typ (Io=100%)
CURRENT[A]
ACIN 115V 3.0typ (Io=100%) 3.3typ (Io=100%)
ACIN 230V 1.5typ (Io=100%) 1.7typ (Io=100%)
FREQUENCY[Hz]
EFFICIENCY[%]
50 / 60 (47 - 63)
ACIN 100V 73typ (Io=100%)
ACIN 115V 74typ (Io=100%)
ACIN 230V 77typ (Io=100%)
ACIN 100V 0.99typ (Io=100%)
ACIN 115V 0.98typ (Io=100%)
ACIN 230V 0.95typ (Io=100%)
79typ (Io=100%)
80typ (Io=100%)
82typ (Io=100%)
81typ (Io=100%)
82typ (Io=100%)
84typ (Io=100%)
82typ (Io=100%)
83typ (Io=100%)
86typ (Io=100%)
83typ (Io=100%)
83typ (Io=100%)
87typ (Io=100%)
82typ (Io=100%)
83typ (Io=100%)
86typ (Io=100%)
INPUT
POWER FACTOR
ACIN 100V 20typ (Io=100%) Ta=25Cat cold start
INRUSH CURRENT[A] ACIN 115V 20typ (Io=100%) Ta=25Cat cold start
ACIN 230V 40typ (Io=100%) Ta=25Cat cold start
LEAKAGE CURRENT[mA]
VOLTAGE[V]
0.75max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)
12 15 24
5
36
48
ACIN 85-100V Output derating is required at ACIN 100V or less (Refer to “Derating”)
CURRENT[A]
WATTAGE[W]
ACIN 100V-264V 50
25
20
12.5
8.4
6.3
ACIN 85-100V Output derating is required at ACIN 100V or less (Refer to “Derating”)
ACIN 100V-264V 250
300
300
300
302.4
302.4
*
3
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
48max
100max
120max
160max
150max
180max
120max
180max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
144max
150max
150max
160max
200max
240max
360max
440max
144max
192max
300max
150max
400max
200max
500max
480max
600max
192max
*
3
0 to +50C 80max
-10 to 0C 140max
0 to +50C 120max
-10 to 0C 160max
0 to +50C 50max
-10 to +50C 75max
RIPPLE[mVp-p]
*1
*1
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
*
2
20max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
300typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 to 5.50
10.80 to 13.20
12.00 to 12.48
13.50 to 16.50
15.00 to 15.60
21.60 to 26.40
24.00 to 24.96
32.40 to 39.60
36.00 to 37.44
43.20 to 52.80
48.00 to 49.92
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
5.00 to 5.15
Works over 105% of rating and recovers automatically
13.80 to 16.80 17.25 to 21.00
OVERVOLTAGE PROTECTION[V] 5.75 to 7.00
27.60 to 33.60
41.40 to 50.40
55.20 to 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
LED (Green)
Not provided
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT RC
INPUT-FG
OUTPUT RC-FG
OUTPUT-RC
Optional (Required external power source. Option -R)
*
9
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
-20 to +70C(Refer to “Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
ISOLATION
*
*
*
9
9
4
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL62368-1, C-UL (CSA62368-1), EN62368-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
SAFETY AND
NOISE
REGULATIONS
*
8
June 25, 2020
PJA-6
PJA300F
SPECIFICATIONS
CASE SIZE/WEIGHT
COOLING METHOD
102X41X190mm [4.02X1.61X7.48 inches] (Excluding terminal block and screw) (WXHXD) / 1.0kg max
Forced cooling (internal fan)
OTHERS
*
*
7
5
WARRANTY WARRANTY
5 years (subject to the operating conditions)
*1 This is the result of measurement of the testing board with capacitors of *3 Consult us about dynamic load and input response.
isolated from input, output, and FG.
22mF and 0.1mF placed at 150 mm from the output terminals by a 20
MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken
RM103.
*4 Output power derating is required. Refer to “Derating”.
*5 See 4 in Instruction Manual for more details.
*
Do not use the power supply in overcurrent conditions or in unspecified
input voltage ranges. Otherwise the internal components may be
damaged.
*6 Consult us about safety agency approvals for the models with optional functions.
*7 The fan speed slows down at no load.
See 1.6 of Instruction Manual for more details.
*
*
Parallel operation is not possible with this mode.
Sound noise may be heard from the power supply when used for
pulse load.
*2 Drift is the change in DC output for an eight hour period after a half-hour *8 Consult us about other classes.
warm-up at 25C.
*9 The RC terminal is added to option –R models. The RC terminal is
Features
-
-
-
-
-
-
-
Cost-effective
Longer life (see Instruction Manual)
Low profile (meets 1U height = 41 mm or 1.61 inches)
Wide operating temperature range (-20 to +70 Refer to “Derating”)
Slow fan speed at no load
Complies with SEMI F-47
Many optional functions
Block diagram
FUSE
250V 10A
INRUSH
CURRENT
LIMIT
NOISE
FILTER
RECTIFIER
AC IN 85 - 264V
FG
CURRENT
SENSING
CONTROL
BOOSTER
INDUCTOR
RECTIFIER
AND
FILTER
CURRENT
SENSING
CONTROL
OVER VOLTAGE
PROTECTION
INVERTER
CONTROL
RECTIFIER
AND
FILTER
INVERTER
DC OUT
THERMAL
PROTECTION
CONTROL
FAN
External view
The external size of –V option and –R option models is different from the standard model. See “6. Options and Others” in Instruction
Manual for more details.
16.8 1.5 (LED)
[0.66]
12.7 1.5 (potentiometer)
[0.5]
Name plate
4-M4
Mounting Hole
(Bottom side)
20max
LED
[0.79max]
Output voltage
adjustable potentiometer
Output terminal(+)
Output terminal(–)
FG(
AC(N)
AC(L)
)
Terminal cover
M4
12.5
[0.49]
150 0.5
[5.91]
16.6 1.5
[0.65]
190
5max
[7.48]
[0.2max]
¶ Tolerance : 1 [ 0.04]
¶
¶
¶
¶
¶
¶
¶
¶
Weight
PCB Material/thickness
Chassis material
Case material : Galvanizing steel
Dimensions in mm, [ ]=inches
Mounting torque : 1.2N m max
Screw tightening torque : 1.6N m max
Connect the input FG to safety earth ground.
: 1.0kg max
AIR FLOW
:
FR-4 / 1.6mm [0.06inches]
:
Aluminum
19.5
[0.77]
150 0.5
[5.91]
4-M4
Mounting Hole
June 25, 2020
PJA-7
Ordering information
AC-DC Power Supplies Enclosed Type
PJ
A
600
F
-O -O
5 6
PJA600F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-16-472
R
*6
6Optional
C : with Coating
G: Low leakage current
V : External potentiometer for
output voltage adjustment
W: Parallel operation,
LV alarm and Remote sensing
R : Remote on/off
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
(Required external power source)
F4: Low speed fan
See 6.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
SPECIFICATIONS
MODEL
PJA600F-5
PJA600F-12
PJA600F-15
PJA600F-24
PJA600F-36
PJA600F-48
VOLTAGE[V]
AC85 - 264 1f(Output derating is required at AC85V - 100V. Refer to “Derating” and instruction manual 1.1, 3)
ACIN 100V 6.7typ (Io=100%) 7.5typ (Io=100%)
CURRENT[A]
ACIN 115V 5.7typ (Io=100%) 6.5typ (Io=100%)
ACIN 230V 2.8typ (Io=100%) 3.2typ (Io=100%)
FREQUENCY[Hz]
EFFICIENCY[%]
50 / 60 (47 - 63)
ACIN 100V 76typ (Io=100%)
ACIN 115V 77typ (Io=100%)
ACIN 230V 79typ (Io=100%)
ACIN 100V 0.99typ (Io=100%)
ACIN 115V 0.98typ (Io=100%)
ACIN 230V 0.95typ (Io=100%)
81typ (Io=100%)
82typ (Io=100%)
84typ (Io=100%)
82typ (Io=100%)
82typ (Io=100%)
85typ (Io=100%)
84typ (Io=100%)
85typ (Io=100%)
88typ (Io=100%)
85typ (Io=100%)
86typ (Io=100%)
88typ (Io=100%)
85typ (Io=100%)
85typ (Io=100%)
88typ (Io=100%)
INPUT
POWER FACTOR
ACIN 100V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)
INRUSH CURRENT[A] ACIN 115V 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)
ACIN 230V 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
1.5max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)
12 15 24
5
36
48
ACIN 85-100V Output derating is required at ACIN 100V or less (Refer to “Derating”)
CURRENT[A]
WATTAGE[W]
ACIN 100V-264V 100
50
40
25
16.7
12.5
ACIN 85-100V Output derating is required at ACIN 100V or less (Refer to “Derating”)
ACIN 100V-264V 500
600
600
600
601.2
600
*
7
LINE REGULATION[mV]
LOAD REGULATION[mV]
20max
40max
48max
100max
120max
160max
150max
180max
120max
180max
48max
60max
120max
120max
160max
150max
180max
150max
180max
60max
96max
150max
120max
160max
150max
180max
240max
290max
96max
144max
150max
150max
160max
200max
240max
360max
440max
144max
192max
300max
150max
400max
200max
500max
480max
600max
192max
*
7
0 to +50C 80max
-20 to 0C 140max
0 to +50C 120max
-20 to 0C 160max
0 to +50C 50max
-20 to +50C 75max
RIPPLE[mVp-p]
*1
*1
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
*
2
20max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
300typ (ACIN 100V, Io=100%)
20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 4.50 to 5.50
10.80 to 13.20
12.00 to 12.48
13.50 to 16.50
15.00 to 15.60
21.60 to 26.40
24.00 to 24.96
32.40 to 39.60
36.00 to 37.44
43.20 to 52.80
48.00 to 49.92
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
5.00 to 5.15
Works over 105% of rating and recovers automatically
13.80 to 16.80 17.25 to 21.00
OVERVOLTAGE PROTECTION[V] 5.75 to 7.00
27.60 to 33.60
41.40 to 50.40
55.20 to 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
LED (Green)
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT RC
INPUT-FG
OUTPUT RC-FG
OUTPUT-RC
Optional (Option -W)
Optional (Required external power source. Option -R)
*
3
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
-20 to +70C(Refer to “Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
ISOLATION
*
*
*
3
3
4
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL62368-1, C-UL (CSA62368-1), EN62368-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
SAFETY AND
NOISE
REGULATIONS
*
9
June 25, 2020
PJA-8
PJA600F
SPECIFICATIONS
CASE SIZE/WEIGHT
COOLING METHOD
120X61X215mm [4.72X2.40X8.46 inches] (Excluding terminal block and screw) (WXHXD) / 2.0kg max
Forced cooling (internal fan)
OTHERS
*
*
8
5
WARRANTY WARRANTY
5 years (subject to the operating conditions)
*1 This is the result of measurement of the testing board with capacitors of *3 The RC terminal is added to option –R models. The RC terminal is
*9 Consult us about other classes.
22mF and 0.1mF placed at 150 mm from the output terminals by a 20
MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken
RM103.
isolated from input, output, and FG.
*
Do not use the power supply in overcurrent conditions or in unspecified
input voltage ranges. Otherwise the internal components may be damaged.
Parallel operation is allowed for PLA600FA models with the –W option only.
Sound noise may be heard from the power supply when used for pulse load.
*4 Output power derating is required. Refer to “Derating”.
*5 See 4 in Instruction Manual for more details.
*
*
See 1.6 of Instruction Manual for more details.
*6 Consult us about safety agency approvals for the models with optional functions.
*2 Drift is the change in DC output for an eight hour period after a half-hour *7 Consult us about dynamic load and input response.
warm-up at 25C.
*8 The fan speed slows down at no load.
Features
-
-
-
-
Cost-effective
-
-
Slow fan speed at no load
Complies with SEMI F-47
Many optional functions
Longer life (see Instruction Manual)
Low profile (meets 2U height = 61 mm or 2.40 inches)
Wide operating temperature range (-20 to +70 Refer to
“Derating”)
-
Block diagram
BOOSTER
INDUCTOR
FUSE
250V 16A
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
NOISE
FILTER
CURRENT
SENSING
RECTIFIER
AC IN 85 - 264V
FG
INVERTER
CONTROL
CURRENT
SENSING
RC (-R)
External source
THERMAL
PROTECTION
PARALLEL-OPERATION
CIRCUIT
CONTROL
INVERTER
CONTROL
Current balance (-W)
Remote sensing (-W)
LV alarm (-W)
OVER VOLTAGE
PROTECTION
DETECTING
OUTPUT VOLTAGE
RECTIFIER
AND
DC OUT
FILTER
CONTROL
FAN
External view
The external size of –V option, –W option and –R option models is different from the standard model. See “6. Options and Others” in
Instruction Manual for more details.
26.6 1.5
[1.05]
16.6 1.5
[0.65]
15.8 1.5(LED)
[0.62]
Terminal cover
11.7 1.5(potentiometer)
[0.46]
Name plate
4-M4
Mounting Hole
(Bottom side)
M4
(+V,-V)
LED
21max
[0.83max]
Output voltage
adjustable potentiometer
Output terminal (+)
Output terminal (-)
FG(
)
AC(N)
AC(L)
15.6 1.5 M3.5
35
[1.38]
150 0.5
[5.91]
[0.61]
(AC,FG)
215
3max
[8.46]
[0.12max]
¶ Tolerance : 1 [ 0.04]
¶
¶
¶
¶
¶
¶
¶
Weight
PCB Material/thickness
Chassis material Galvanizing steel
Case material Galvanizing steel
Dimensions in mm, [ ]=inches
Mounting torque 1.5N-m max
Screw tightening torque M3.5 0.8N-m max
M4 1.6N-m max
Connect the input FG to safety earth ground.
: 2.0kg max
:
FR-4 / 1.6mm [0.06inches]
AIR FLOW
:
:
:
:
35
[1.38]
150 0.5
[5.91]
¶
4-M4
Mounting Hole
June 25, 2020
PJA-9
Ordering information
AC-DC Power Supplies Enclosed Type
PJ
A 1000 F
-O -O
5 6
PJA1000F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-20-472
R
*
8
6Optional
C : with Coating
G: Low leakage current
V : External potentiometer for
output voltage adjustment
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
W
:
Parallel operation, LV alarm
and Remote sensing
R : Remote on/off
(Required external power
source)
See 6.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
SPECIFICATIONS
MODEL
PJA1000F-12
AC85 - 264 1f(Output derating is required at AC85V - 115V. Refer to “Derating” and instruction manual 1.1, 3)
ACIN 100V 12.5typ (Io=90%)
PJA1000F-15
PJA1000F-24
PJA1000F-36
PJA1000F-48
VOLTAGE[V]
CURRENT[A]
ACIN 115V 11.0typ (Io=100%)
ACIN 230V 5.5typ (Io=100%)
50 / 60 (47 - 63)
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V 81typ (Io=90%)
ACIN 115V 82typ (Io=100%)
ACIN 230V 85typ (Io=100%)
ACIN 100V 0.98typ (Io=90%)
ACIN 115V 0.98typ (Io=100%)
ACIN 230V 0.95typ (Io=100%)
82typ (Io=90%)
82typ (Io=100%)
85typ (Io=100%)
84typ (Io=90%)
85typ (Io=100%)
88typ (Io=100%)
84typ (Io=90%)
85typ (Io=100%)
88typ (Io=100%)
84typ (Io=90%)
85typ (Io=100%)
88typ (Io=100%)
INPUT
POWER FACTOR
ACIN 100V 15/30typ (Io=90%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start)
INRUSH CURRENT[A] ACIN 115V 15/30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start)
ACIN 230V 30/30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
1.5max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)
12
15
24
36
28
48
21
ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to “Derating”)
CURRENT[A]
WATTAGE[W]
ACIN 115V-264V 84
67
42
ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to “Derating”)
ACIN 115V-264V 1008
1005
1008
1008
1008
*
2
LINE REGULATION[mV]
LOAD REGULATION[mV]
48max
60max
96max
144max
150max
150max
200max
200max
240max
360max
440max
144max
192max
300max
200max
500max
300max
600max
480max
600max
192max
*
2
100max
120max
180max
240max
210max
270max
150max
180max
60max
150max
120max
160max
150max
180max
240max
290max
96max
0 to +50C 180max
-20 to 0C 240max
0 to +50C 210max
-20 to 0C 270max
0 to +50C 120max
-20 to +50C 180max
RIPPLE[mVp-p]
*1
*1
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
*
3
48max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
800typ (ACIN 115V, Io=100%)
20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 10.80 to 13.50
13.50 to 17.30
15.00 to 15.60
20.40 to 28.50
24.00 to 24.96
30.60 to 40.80
36.00 to 37.44
40.80 to 55.20
48.00 to 49.92
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
12.00 to 12.48
Works over 105% of rating and recovers automatically
18.00 to 21.80 28.80 to 34.80
OVERVOLTAGE PROTECTION[V] 14.40 to 17.40
43.20 to 52.20
57.00 to 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
LED (Green)
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
Optional (Option -W)
Optional (Required external power source. Option -R)
AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
4
-20 to +70C(Refer to “Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
ISOLATION
OUTPUT-FG
*
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL62368-1, C-UL (CSA62368-1), EN62368-1 Complies with DEN-AN
Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
Complies with IEC61000-3-2 class A
SAFETY AND
NOISE
REGULATIONS
*
5
June 25, 2020
PJA-10
PJA1000F
SPECIFICATIONS
CASE SIZE/WEIGHT
COOLING METHOD
150X61X240mm [5.91X2.40X9.45 inches] (Excluding terminal block and screw) (WXHXD) / 2.8kg max
Forced cooling (internal fan)
OTHERS
*
*
6
7
WARRANTY WARRANTY
5 years (subject to the operating conditions)
*1 This is the result of measurement of the testing board with capacitors of *3 Drift is the change in DC output for an eight hour period after a half-hour
*8 Consult us about safety agency approvals for the models with
22mF and 0.1mF placed at 150 mm from the output terminals by a 20
MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken
RM103.
warm-up at 25C.
optional functions.
*4 Output power derating is required. Refer to “Derating”.
*5 Consult us about other classes.
*
Do not use the power supply in overcurrent conditions or in unspecified
input voltage ranges. Otherwise the internal components may be damaged.
Parallel operation is not possible with this mode.
See 1.6 of Instruction Manual for more details.
*6 The fan speed slows down or stops at no load.
*7 See 4 in Instruction Manual for more details.
*
*
*2 Consult us about dynamic load and input response.
Audible noise may be heard from the power supply when used for pulse load.
Features
-
-
-
Cost-effective
-
-
Wide operating temperature range (-20 to +70 Refer to
“Derating”)
Longer life (see Instruction Manual)
Low profile (meets 2U height = 61 mm or 2.4 inches)
Stop or slow fan speed at no load
Block diagram
BOOSTER
INDUCTOR
FUSE
250V 20A
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
NOISE
CURRENT
SENSING
RECTIFIER
AC IN 85 - 264V
FILTER
INVERTER
CONTROL
FG
CURRENT
SENSING
RC (-R)
External source
THERMAL
PROTECTION
PARALLEL-OPERATION
CIRCUIT
CONTROL
INVERTER
CONTROL
Current balance (-W)
Remote sensing (-W)
LV alarm (-W)
OVER VOLTAGE
PROTECTION
DETECTING
OUTPUT VOLTAGE
RECTIFIER
AND
DC OUT
FILTER
CONTROL
FAN
External view
The external size of –V option, –W option and –R option models is different from the standard model. See “6. Options and Others” in
Instruction Manual for more details.
4-M4
2-f9
AIR FLOW
8-M4
Mounting hole
(Both sides)
29
197±0.5
[7.76]
[1.14]
7
13
[0.28]
[0.51]
15.8±1.5 (LED)
[0.62]
38max
[1.5max]
240
[9.45]
4max
[0.16max]
11.7±1.5 (potentiometer)
[0.46]
29
[1.14]
131±0.5
[5.16]
Output terminal(+)
Output terminal(-)
LED
Output voltage
adjustable potentiometer
¶
Tolerance : ±± ꢀ±[ꢁ[.0
¶ Weight 2ꢁ8kg max
¶ PCB Material/thickness
¶ Chassis material Galvanizing steel
:
:
FR-. / ±ꢁ6mm ꢀ[ꢁ[6inches0
FG(
)
:
AC(N)
AC(L)
¶ Case material : Galvanizing steel
¶ Dimensions in mm, ꢀ 0=inches
¶ Mounting torque : ±ꢁ5N-m max
M4
¶ Screw tightening torque : ±ꢁ6N-m max
¶ Output terminal M. tightening torque : ±ꢁ2N-m max
¶ Connect the input FG to safety earth groundꢁ
Input terminal cover
Name plate
4-M4
Mounting hole
(Bottom side)
23max
[0.91max]
16±1.5
[0.63]
June 25, 2020
PJA-11
Ordering information
AC-DC Power Supplies Enclosed Type
PJ
A 1500 F
-O -O
5 6
PJA1500F
1
2
3
4
1Series name
2Single output
3Output wattage
4Universal input
5Output voltage
Example recommended EMI/EMC filter
NAC-20-472
R
*
8
6Optional
C : with Coating
G: Low leakage current
V : External potentiometer for
output voltage adjustment
High voltage pulse noise type : NAP series
Low leakage current type : NAM series
W
:
Parallel operation, LV alarm
and Remote sensing
R : Remote on/off
(Required external power
source)
See 6.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
SPECIFICATIONS
MODEL
PJA1500F-12
AC85 - 264 1f(Output derating is required at AC85V - 115V. Refer to “Derating” and instruction manual 1.1, 3)
ACIN 100V 18typ (Io=90%)
PJA1500F-15
PJA1500F-24
PJA1500F-36
PJA1500F-48
VOLTAGE[V]
CURRENT[A]
ACIN 115V 16typ (Io=100%)
ACIN 230V 8typ (Io=100%)
50 / 60 (47 - 63)
FREQUENCY[Hz]
EFFICIENCY[%]
ACIN 100V 81typ (Io=90%)
ACIN 115V 82typ (Io=100%)
ACIN 230V 85typ (Io=100%)
ACIN 100V 0.98typ (Io=90%)
ACIN 115V 0.98typ (Io=100%)
ACIN 230V 0.95typ (Io=100%)
82typ (Io=90%)
82typ (Io=100%)
85typ (Io=100%)
84typ (Io=90%)
85typ (Io=100%)
88typ (Io=100%)
84typ (Io=90%)
85typ (Io=100%)
88typ (Io=100%)
84typ (Io=90%)
84typ (Io=100%)
87typ (Io=100%)
INPUT
POWER FACTOR
ACIN 100V 15/30typ (Io=90%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start)
INRUSH CURRENT[A] ACIN 115V 15/30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start)
ACIN 230V 30/30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start)
LEAKAGE CURRENT[mA]
VOLTAGE[V]
1.5max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)
12
15
24
36
42
48
32
ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to “Derating”)
CURRENT[A]
WATTAGE[W]
ACIN 115V-264V 125
100
64
ACIN 85-115V Output derating is required at ACIN 115V or less (Refer to “Derating”)
ACIN 115V-264V 1500
1500
1536
1512
1536
*
2
LINE REGULATION[mV]
LOAD REGULATION[mV]
48max
60max
96max
144max
150max
150max
200max
200max
240max
360max
440max
144max
192max
300max
200max
500max
300max
600max
480max
600max
192max
*
2
100max
120max
180max
240max
210max
270max
150max
180max
60max
150max
120max
160max
150max
270max
240max
290max
96max
0 to +50C 180max
-20 to 0C 240max
0 to +50C 210max
-20 to 0C 270max
0 to +50C 120max
-20 to +50C 180max
RIPPLE[mVp-p]
*1
*1
OUTPUT
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
*
3
48max
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
800typ (ACIN 115V, Io=100%)
20typ (ACIN 115V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 10.80 to 13.50
13.50 to 17.30
15.00 to 15.60
20.40 to 28.50
24.00 to 24.96
30.60 to 40.80
36.00 to 37.44
40.80 to 55.20
48.00 to 49.92
OUTPUT VOLTAGE SETTING[V]
OVERCURRENT PROTECTION
12.00 to 12.48
Works over 105% of rating and recovers automatically
18.00 to 21.80 28.80 to 34.80
OVERVOLTAGE PROTECTION[V] 14.40 to 17.40
43.20 to 52.20
57.00 to 67.20
PROTECTION
CIRCUIT AND OPERATING INDICATION
LED (Green)
OTHERS
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG
Optional (Option -W)
Optional (Required external power source. Option -R)
AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At room temperature)
AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MWmin (At room temperature)
AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At room temperature)
4
-20 to +70C(Refer to “Derating”), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
ISOLATION
OUTPUT-FG
*
OPERATING TEMP.,HUMID.AND ALTITUDE
STORAGE TEMP.,HUMID.AND ALTITUDE -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
ENVIRONMENT
2
VIBRATION
10 - 55Hz, 19.6m/s (2G), 3minutes period, 60minutes each along X, Y and Z axes
2
IMPACT
196.1m/s (20G), 11ms, once each X, Y and Z axes
AGENCY APPROVALS
CONDUCTED NOISE
HARMONIC ATTENUATOR
UL62368-1, C-UL (CSA62368-1), EN62368-1, Complies with DEN-AN
SAFETY AND
NOISE
REGULATIONS
Complies with FCC-A, VCCI-A, CISPR22-A, EN55011-A, EN55022-A, additional EMI/EMC Filter is required for meeting class B
Complies with IEC61000-3-2 class A
*
5
June 25, 2020
PJA-12
PJA1500F
SPECIFICATIONS
CASE SIZE/WEIGHT
COOLING METHOD
178X61X268mm [7.01X2.40X10.55 inches] (Excluding terminal block and screw) (WXHXD) / 3.5kg max
Forced cooling (internal fan)
OTHERS
*
*
6
7
WARRANTY WARRANTY
5 years (subject to the operating conditions)
*1 This is the result of measurement of the testing board with capacitors of *3 Drift is the change in DC output for an eight hour period after a half-hour
*8 Consult us about safety agency approvals for the models with
22mF and 0.1mF placed at 150 mm from the output terminals by a 20
MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken
RM103.
warm-up at 25C.
optional functions.
*4 Output power derating is required. Refer to “Derating”.
*5 Consult us about other classes.
*
Do not use the power supply in overcurrent conditions or in unspecified
input voltage ranges. Otherwise the internal components may be damaged.
Parallel operation is not possible with this mode.
See 1.6 of Instruction Manual for more details.
*6 The fan speed slows down or stops at no load.
*7 See 4 in Instruction Manual for more details.
*
*
*2 Consult us about dynamic load and input response.
Audible noise may be heard from the power supply when used for pulse load.
Features
-
-
-
Cost-effective
-
-
Wide operating temperature range (-20 to +70 Refer to
“Derating”)
Longer life (see Instruction Manual)
Low profile (meets 2U height = 61 mm or 2.4 inches)
Stop or slow fan speed at no load
Block diagram
BOOSTER
INDUCTOR
FUSE
250V 30A
INRUSH
CURRENT
LIMIT
RECTIFIER
AND
FILTER
NOISE
CURRENT
SENSING
RECTIFIER
AC IN 85 - 264V
FILTER
INVERTER
CONTROL
FG
CURRENT
SENSING
RC (-R)
External source
THERMAL
PROTECTION
PARALLEL-OPERATION
CIRCUIT
CONTROL
INVERTER
CONTROL
Current balance (-W)
Remote sensing (-W)
LV alarm (-W)
OVER VOLTAGE
PROTECTION
DETECTING
OUTPUT VOLTAGE
RECTIFIER
AND
DC OUT
FILTER
CONTROL
FAN
External view
The external size of –V option, –W option and –R option models is different from the standard model. See “6. Options and Others” in
Instruction Manual for more details.
4-M4
2-f9
AIR FLOW
30
[1.18]
215±0.5
[8.46]
8-M4
Mounting hole
(Both sides)
7
[0.28]
13
[0.51]
15.8±1.5 (LED)
[0.62]
38max
268
4max
[1.5max]
[10.55]
[0.16max]
11.7±1.5 (potentiometer)
[0.46]
30
[1.18]
215±0.5
[8.46]
Output terminal(+)
Output terminal(-)
LED
Output voltage
adjustable potentiometer
¶
Tolerance : ±± ꢀ±[ꢁ[.0
¶ Weight 3ꢁ5kg max
¶ PCB Material/thickness
¶ Chassis material Galvanizing steel
:
:
FR-. / ±ꢁ6mm ꢀ[ꢁ[6inches0
:
FG(
)
¶ Case material : Galvanizing steel
¶ Dimensions in mm, ꢀ 0=inches
¶ Mounting torque : ±ꢁ5N-m max
AC(N)
AC(L)
M4
¶ Screw tightening torque : ±ꢁ6N-m max
Name plate
Input terminal cover
16±1.5
[0.63]
23max
4-M4
Mounting hole
(Bottom side)
¶ Output terminal M. tightening torque : ±ꢁ2N-m max
¶ Connect the input FG to safety earth groundꢁ
[0.91max]
June 25, 2020
PJA-13
PJA-series
Assembling and Installation Method
Chassis of
PJA series
■Do not insert a screw more than 6mm from the outside of a power supply to keep enough insulation
distance between the screw and internal components.
Chassis of
customer system
Mounting Screw
6mm max
PJA100F, PJA150F
¿
Terminal block
More than
20mm
Terminal block
(A)
(B)
(C)
■If you use two or more power supplies side by side, please keep a sufficient distance between them to allow enough air ventilation.
■Ambient temperature around each power supply should not exceed the temperature range shown in “derating”.
PJA300F
¿
Vent hole
side
More than
30mm
More than
30mm
More than
Terminal block
Terminal block
Terminal block
More than
30mm
Not allowed
Terminal block
F
A
N
Fan side
side
30mm
Vent hole
side
Air flow
Terminal block
Terminal block
(D)
(A)
(B)
(
C)
(E)
PJA600F
¿
More than
30mm
More than
30mm
Vent hole
Terminal
block
side
Vent hole
side
Terminal block
More than
Terminal block
30mm
Fixed
screw
Terminal block
Not allowed
F
A
N
Fixed
Fixed
screw
(4pcs.)
Fan side
More than
side
30mm
screw
(4pcs.)
(4pcs.)
Air flow
Terminal block
Fixed screw
(4pcs.)
Fixed screw
(4pcs.)
Terminal block
(D)
(A)
(B)
(C)
(E)
PJA1000F, PJA1500F
¿
More than
30mm
More than
30mm
More than
30mm
More than
30mm
Fixed
More than
30mm
More than
30mm
Vent hole
side
screw
Terminal
block
Terminal
block side
Terminal
(4pcs.)
Terminal
block
F
A
N
F
A
N
More than
30mm
block side
F
A
N
F
A
N
Terminal
block
Fan side
Fan
side
Air flow
Air flow
Fixed screw
(4pcs.)
Fixed screw
(4pcs.)
Fixed screw
(4pcs.)
Fixed screw
(4pcs.)
(C)
(A)
(B)
Terminal
block
Fixed
screw
(4pcs.)
Fixed
screw
(4pcs.)
Not
allowed
Terminal
block
Terminal
block
(D)
(E)
(F)
June 25, 2020
PJA-14
PJA-series
Assembling and Installation Method
■When mounting the power supply with screws, it is recommended that this be done as shown above . If other methods are used, be sure
the weight of the power supply is taken into account.
■Avoid the not allowed installation method as it gives excessive stress to the mounting holes.
■Do not block air flow of the built-in fan (terminal block and ventilation hole).
■If the power supply is used in a dusty environment, use an airfilter. Make sure air flow is not blocked.
■If the built-in fan stops, thermal protection will work and the outputwill stop.
■The life expectancy (R(t)=90%) of the built-in fan varies depending on the operating condition.
Derating
Input voltage Derating Curve
¿
[%]
100
3
1
2
90
85
80
1PJA100F,PJA150F
PJA1000F,PJA1500F
2PJA300F
3PJA600F
85 100115
[AC V]
PJA100F/150F-12,15
Ambient temperature Derating Curve
(Reference value)
100
PJA100F/150F-24,36,48
Ambient temperature Derating Curve
(Reference value)
¿
¿
100
3
3
2
1
2
1
80
80
60
50
40
30
20
60
50
40
1Convection (A mount)
2Convection (B, C mount)
3Forced air (0.5m3 / min)
1Convection (A mount)
2Convection (B, C mount)
3Forced air (0.5m3 / min)
30
20
0
0
-20
-10
0
10
20
30
40
50 55 60
70
80
-20
-10
0
10
20
30 35 40 45 50 55 60
70
80
Ambient temperature [C]
Ambient temperature [C]
■In the hatched area, the specification of Ripple, Ripple Noise is different from other area.
■The ambient temperature should be measured 5 to 10 cm away from the power supply so that it won’t be influenced by the heat from the
power supply. Please consult us for more details.
■Make sure the temperature at point A and point B is less than the temperatures shown in Instruction Manual 3.
PJA300F
PJA600F/1000F/1500F
¿
¿
Ambient temperature Derating Curve
Ambient temperature Derating Curve
100
100
1
2
80
80
60
40
20
0
60
50
1PJA1500F-12
PJA1500F-15
PJA1500F-36
2other
40
20
0
-20
-10
0
10
20
30
40
50
60
70
80
-20
-10
0
10
20
30
40
50
60
70
80
Ambient temperature [
]
C
Ambient temperature [
]
C
■The ambient temperature is defined as the temperature of the air (at the terminal block side) that the built-in cooling fan blows into the pow-
er supply. Please pay attention to the heat generated by the input and output wires. Please consult us for more details.
June 25, 2020
PJA-15
PJA-series
Instruction Manual
◆It is neccessary to read the “Instruction Manual” and “Before using our product” before you use our product.
Instruction Manual https://en.cosel.co.jp/product/powersupply/PJA/
Before using our product https://en.cosel.co.jp/technical/caution/index.html
PJA
NOTICE
Basic Characteristics Data
Series/Parallel
operation availability
Inrush
current
Switching
frequency
[kHz]
Input
current
[A]
PCB/Pattern
Rated
input fuse
Model
Circuit method
Active filter
protection
circuit
Single Double
Series
Parallel
sided sided operation operation
Material
FR-4
40 to 160
PJA100F
PJA150F
PJA300F
PJA600F
PJA1000F
PJA1500F
1.2 *1 250V 3.15A Thermistor
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Flyback converter 20 to 150 *2
Active filter 40 to 160
Flyback converter 20 to 150 *2
1.7 *1 250V 4A
Thermistor
FR-4
FR-4
FR-4
FR-4
FR-4
Active filler
Forward converter
Active filler
60
3.9 *3 250V 10A Thermistor
No
140
60
7.5 *3 250V 16A
12.5 *1 250V 20A
18.0 *1 250V 30A
SCR
*4
*4
*4
220
Forward converter
Active filter
65
210
65
TRIAC
TRIAC
Forward converter
Active filter
Forward converter
210
*1 The input current shown is at ACIN 100V and 90% load.
*2 The burst mode frequency varies according to the operating conditions. Consult us for more details.
*3 The input current shown is at ACIN 100V and 100% load.
*4 Parallal operation is possible with -W option. see “6.Option and Other” is Instruction Manual.
June 25, 2020
PJA-16
相关型号: