ESP-03-681 [COSEL]
LINE FILTER 250VDC/VAC 3A CHAS;型号: | ESP-03-681 |
厂家: | COSEL CO., LTD. |
描述: | LINE FILTER 250VDC/VAC 3A CHAS LTE |
文件: | 总2页 (文件大小:415K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Ordering information
Small, Single phase input type: Screwless terminal (1-Stage filter)
ESC -10 -472 -O
ESC/ESM/ESP series
1
2
3
4
1Series Name
2Rated Current
R
3
Line to ground capacitor code:Refer to table 1.1.
table1.1 Line to ground capacitor code
ESECSEMSP
Line to ground
Leakage Current
Code
capacitor
(Input 125/250V 60Hz)
(nominal value)
000
101
221
331
● ●
5
A / 10 A max Not Provided
● ● 12.5
● ● 25
● ● 37.5
● ● 50
● 75.5
A / 25 A max
A / 50 A max
A / 75 A max
A / 100 A max
A / 150 A max
100pF
220pF
330pF
470pF
680pF
471
681 ●
102 ●
222 ●
332 ●
472 ●
●
●
●
●
0.13 mA /0.25mA max
0.25 mA /0.5 mA max
0.38 mA /0.75mA max
0.5 mA /1.0 mA max
1,000pF
2,200pF
3,300pF
4,700pF
When the line to ground capacitor code is
different, the attenuation characteristic is
different.
*
4Option
D:DIN rail installation type
The dimensions change when the option is set.
Refer to External view.
*
DIN rail installation type is option
Electric cable is not appended.
Features of ESC/ESM/ESP series
Single Phase 250VAC (1-Stage filter)
Small EMI/EMC Filters that change input-output terminal and protection earth terminal of EA series into
screwless terminal type
-
-
Torque management is unnecessary with screwless
-
ESC : Attenuation type from 150kHz to 1MHz
ESP : Outside impulse attenuation type
ESM : Low leakage current type
Specifications
ESC-03-472
ESM-03-000
ESP-03-472
AC 1f250 / DC250
3
ESC-06-472
ESM-06-000
ESP-06-472
ESC-10-472
ESM-10-000
ESP-10-472
ESC-16-472
ESM-16-000
ESP-16-472
No.
Items
1
2
Rated Voltage[V]
Rated Current[A]
6
10
16
3
Test Voltage (Terminal-Mounting Plate)
2,500 VAC (Cutoff Current = 20mA), 1minute at room temperature and humidity
4
Isolation Resistance (Terminal-Mounting Plate) 500 VDC 500MWmin at room temperature and humidity
5
Leakage current
Refer to table 1.1
6
DC resistance
180mWmax
110mWmax
40mWmax
20mWmax
7
Safety agency approval temperatures
Operating temperature
Operating humidity
-25 to +85C(Refer to Derating Curve)
-40 to +85C(Refer to Derating Curve)
20 to 95%RH (Non condensing)
8
9
10
11
12
13
14
Storage temperature/humidity
Vibration
-40 to +85C/20 to 95%RH (Non condensing)
2
10 to 55Hz, 19.6m/s (2G), 3min. Period, 1hour each X, Y and Z axis
2
Impact
196.1m/s (20G), 11ms Once each X, Y and Z axis
Safety agency approvals
Case size (without projection) /Weight
UL1283, CSA C22.2 No.8 (C-UL), DIN EN60939 VDE0565 Teil3-1, ENEC (At only AC input)
39X30X85 mm [1.54X1.18X3.35 inches] (WXHXD) /170g max (Option : -D refer to external view)
Circuit Diagram
Derating Curve
Case
100
80
3
1
60
CY
LINE
LOAD
40
CY
4
2
20
0
-40
-30
-20
40
50 55 60
70
80
90
Ambient Temperature [C]
: Mounting Plate
CY : Line to ground capacitor
May 11, 2021
EA/ES-3
ESC/ESM/ESP series
External view
Standard Type
85
[3.35]
78
[3.07]
76.2
Screwless
[3]
Mounting Plate
Terminal
0.5
[2.95]
75
Input
26.5
[1.04]
24
Screwless
Terminal
Terminal
6-Check hole f2.1
[0.08]
Output
Protection Earth
[0.94]
Terminal
Name Plate
Screwless
Terminal
Input
Screwless
Terminal
Terminal
Protection Earth
2-f4.8
Output
[0.19]
Mounting Hole
6-Connection/release button
Terminal
Strip Gauge
¶ Tolerance : 1 [ 0.04]
¶ Weight : 170g max
¶ Mounting Plate : Iron (surface finishing:nickel plating) t=1.0 [0.04]
¶ Case : PBT
¶ Dimensions in mm, [ ]=inches
¶ Refer to instruction manual for details.
DIN rail installation Type
+2
-1
[0.33]
8.5
85
[3.35]
78
Screwless
Terminal
Mounting Plate
[3.07]
76.2
[3]
Input
Screwless
Terminal
26.5
[1.04]
Terminal
6-Check hole f2.1
Protection Earth
Output
24
[0.08]
[0.94]
Terminal
Name Plate
Screwless
Terminal
Input
Screwless
Terminal
Terminal
Protection Earth
6-Connection/release button
Output
Terminal
Strip Gauge
¶ Tolerance : 1 [ 0.04]
¶ Weight : 170g max
¶ Mounting Plate : Iron(surface finishing:nickel plating) t=1.0 [0.04]
¶ Case : PBT
¶ Dimensions in mm, [ ]=inches
¶ Refer to instruction manual for details.
DIN rail
Note when installing the EMI/EMC
¡
Filter on a DIN rail.
When the EMI/EMC Filter is grounded through
the DIN rail, the proper noise attenuation may not
be achieved.
DIN rail
Name Plate
Be sure to connect the protection earth (PE) of
the EMI/EMC Filter body to the earth.
It can connect the ground to either one only.
May 11, 2021
EA/ES-4
相关型号:
©2020 ICPDF网 联系我们和版权申明