SRU [COOPER]

Box Cover Units for Plug Fuses; 盒盖单元插头保险丝
SRU
型号: SRU
厂家: COOPER BUSSMANN, INC.    COOPER BUSSMANN, INC.
描述:

Box Cover Units for Plug Fuses
盒盖单元插头保险丝

文件: 总2页 (文件大小:143K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Box Cover Units  
for Plug Fuses  
Circuit Protection  
Box Cover Units  
For Plug Fuses  
Fuse Holder  
Plug fuse box cover units provide a simple, inexpensive way  
to protect small motors with Edison-type “T”, “TL”, “TC”, “P”  
and “W” plug fuses. Box cover units are easily installed in  
standard electrical boxes. By using fuses sized at the amp  
rating of a motor or slightly larger, optimum overload and  
short-circuit protection is provided. Box cover units are UL  
Listed.  
On/Off Switch  
Receptacle  
Switch Light  
SSY-RL  
Selection Data — Plug Fuse Box Cover Units  
Receptacle  
Outlet to Load  
Motor  
Size  
Agency†  
Listing/  
Certification  
Box Cover  
Cat. No.  
Fuseholder  
Switch  
Switch  
Type Box  
Single  
Double  
125Vac 250Vac Control+ Light++ (Max.)  
General Data  
3
SOU  
SRU  
SSU  
X
4
Hp  
Hp  
Hp  
Hp  
Hp  
Hp  
Hp  
Hp  
Hp  
Hp  
Hp  
Hp  
Hp  
Hp*  
125V, 15A  
UL, CSA  
UL  
1
2 1⁄  
4
" Handy  
" Switch  
X
X
X
X
2
125V, 15A  
1
X
X
X
X
2
125Vac (do not use on DC), 15A  
125V, 15A  
UL, CSA  
UL, CSA  
UL  
3
4
SOW  
SRW  
SSW  
SOX  
SRX  
SSX  
X
1
2 3⁄  
4
X
2
125V, 15A  
1
X
2
125Vac (do not use on DC), 15A  
125V, 15A  
UL, CSA  
UL, CSA  
UL  
3
4
X
1
4" Octagon  
4" Square  
X
2
125V, 15A  
1
X
2
125Vac (do not use on DC), 15A  
125V, 15A  
UL, CSA  
UL, CSA  
UL  
3
4
SOY  
SRY  
SSY  
X
1
X
X
X
2
125V, 15A  
1
X
X
2
125Vac (do not use on DC), 15A  
125Vac (do not use on DC), 15A  
125Vac (do not use on DC)*, 15A  
UL, CSA  
1
2
SSY-RL  
STY*  
X
X
X
1
X
X
X*  
2
UL  
125Vac (do not use on DC);  
can protect two motors**, 15A  
1
SCY**  
X(2)**  
2
Hp(2)**  
UL  
3
SOY-B  
SKA  
X
X
4
Hp  
125V, protects two motors, 15A  
250V, 15A single-phase  
UL  
UL  
UL  
4 11  
Single Gang  
16" Square  
X(15A)  
2 Hp  
1
SSN  
X
X
2
Hp  
125V, 15A Weatherproof  
+
Switch turns power to fused load OFF or ON.  
++ Switch light indicates power to load (dark when switch OFF or fuse open).  
Double-pole switch opens both sides of circuit. STY can be used for two separate 125V motors not larger than 1⁄  
larger than 2 Hp at 250V (Maximum of 150V to ground).  
** The SCY unit can be used for protection of a single motor not larger than 2Hp at 250V (Maximum of 150V to ground).  
UL Guide JAMZ, File E6491; CSA Class 6225-01, File 47235.  
*
2
Hp with the common switch, or a single motor not  
For additional information, visit www.edisonfuse.com  
137  
Box Cover Units  
for Plug Fuses  
1
3
2 ⁄  
4
˝ Handy Boxes  
2 ⁄ ˝ Switch Boxes  
4
SOU  
SRU  
SSU  
SOW  
SRW  
SSW  
11  
4˝ Octagon Boxes  
4- ⁄16˝ Square Boxes  
SOX  
SRX  
SSX  
SKA  
4˝ Square Boxes  
SOY  
SRY  
SSY  
SSY-RL  
SOY-B  
STY  
SCY  
SSN  
For additional information, visit www.edisonfuse.com  
138  

相关型号:

SRU-12VDC-FD-A

Miniature volume, PCB usage
SONGLERELAY

SRU-12VDC-FD-B

Miniature volume, PCB usage
SONGLERELAY

SRU-12VDC-FD-C

Miniature volume, PCB usage
SONGLERELAY

SRU-12VDC-FL-A

Miniature volume, PCB usage
SONGLERELAY

SRU-12VDC-FL-B

Miniature volume, PCB usage
SONGLERELAY

SRU-12VDC-FL-C

Miniature volume, PCB usage
SONGLERELAY

SRU-12VDC-SD-A

Miniature volume, PCB usage
SONGLERELAY

SRU-12VDC-SD-B

Miniature volume, PCB usage
SONGLERELAY

SRU-12VDC-SD-C

Miniature volume, PCB usage
SONGLERELAY

SRU-12VDC-SL-A

Miniature volume, PCB usage
SONGLERELAY

SRU-12VDC-SL-B

Miniature volume, PCB usage
SONGLERELAY

SRU-12VDC-SL-C

Miniature volume, PCB usage
SONGLERELAY