NOS-6 [COOPER]
Electric Fuse, 6A, 600VAC, 50000A (IR), Inline/holder;型号: | NOS-6 |
厂家: | COOPER BUSSMANN, INC. |
描述: | Electric Fuse, 6A, 600VAC, 50000A (IR), Inline/holder 电路保护 |
文件: | 总4页 (文件大小:276K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
NON/NOS, 600/250Vac Class K5 & H
1
NON (250V) ⁄
8
-600A, General Purpose Fuses
Dimensions – in
All Diameters 0.00ꢀ
10.3ꢀ" ( 0.09ꢁ8
2"
(0.0318
0.56" ( 0.00ꢀ8
1/ꢀ to 30A
2.59"
2.06"
ꢁ50 to 600A
3"
ꢀ.63" ( 0.09ꢁ8
(0.0318
0.ꢀ1" ( 0.00ꢀ8
35 to 60A
225 to ꢁ00A
Description: Basic protection 250V NON Class K5 and H
5.ꢀꢀ" ( 0.0628
7.13" ( 0.0628
general purpose, non-current-limiting, one-time fuses.
Catalog Symbol: NON-(amp)
Ratings:
1.06"
1.56"
110 to 200A
70 to 100A
Volts — 250Vac
— 125Vdc (1⁄
Amps — 1⁄
-600A
IR — 50kA Vac RMS Sym. (1⁄
— 10kA Vac RMS Sym. (65-600A)
— 50kA Vdc (1⁄
-60A)
— 10kA Vdc (65-100A)
Agency Information:
CE, UL Listed, Class K5 (1⁄
Class H (65-600A), Std. 248-6 (125Vdc 1⁄
UL Guide JDDZ, File E4274
CSA Certified, Class 1421-01, File 53787 (1⁄
8
-100A)
Features:
• Protect lighting, heating and other circuits not subject to temporary
surges and where available short-circuit currents are relatively low
• NON one-time fuses do not have any appreciable degree of time-
delay and thus should not be specified in circuits where large
transients or motor overloads occur. Use Bussmann advanced
protection FUSETRON™ FRN-R or ultimate protection Low-Peak™
LPN-RK dual-element, time-delay fuses.
• For general purpose circuits, size at amp rating of circuit
• For motor circuits, size at 300% to 400% according to the NEC®
motor ampacity tables 430.247 to 430.250, per 430.6(A)(1)
8
8
-60A)
8
8-60A), Std. 248-9,
8
-100A),
Recommended Fuse Blocks
Fuse Amps
0-30
1-Pole
H25030-1
2-Pole
H25030-2
3-Pole
H25030-3
8
-12A, 65-600A)†
35-60
H25060-1
H25060-2
H25060-3
†
For CSA Certified 15-60A, see PON Data Sheet # 4126.
70-100
110-200
225-400
450-600
HM25100-1CR
HM25200-1CR
HM25400-1CR
HM25600-1CR
HM25100-2CR
HM25200-2CR
HM25400-2CR
HM25600-2CR
HM25100-3CR
HM25200-3CR
HM25400-3CR
HM25600-3CR
Catalog Numbers (amps)
NON-1⁄
NON-1⁄
NON-3⁄
8
NON-3
NON-32⁄10
NON-4
NON-5
NON-6
NON-12
NON-15
NON-20
NON-25
NON-30
NON-35
NON-40
NON-45
NON-50
NON-60
NON-65
NON-70
NON-75
NON-80
NON-90
NON-100
NON-110
NON-125
NON-150
NON-175
NON-200
NON-225
NON-250
NON-300
NON-350
NON-400
NON-450
NON-500
NON-600
2
4
NON-8⁄10
NON-1
For additional information on 250 volt fuse blocks, see Data
Sheet # 1112 (H250) and product brochure # 3192 (HM Se-
ries).
NON-11⁄
4
NON-61⁄
4
NON-11⁄
NON-16⁄10
NON-2
2
NON-7
NON-8
NON-9
NON-10
Fuse Reducers For Class R Fuses
Equipment
Fuse Clips
60A
Desired Fuse
(Case) Size
30A
Catalog Numbers
(Pairs) 250V
NO.263
NON-21⁄
2
Carton Quantity and Weight
30A
60A
60A
100A
100A
200A
NO.213
NO.216
NO.226
NO.2621
NO.2641
NO.2642
100A
Amp Rating
Carton Qty.
1
⁄8
-30
10
10
5
200A
200A
35–60
65–100
110–200
225–400
450–600
400A
1
1
1
For additional information on Class K5 & H fuse reducers, see
Data Sheet # 1118.
0713
BU-SB13738
Page 1 of 4
Data Sheet # 1030
NON/NOS, 600/250Vac Class K5 & H
1
NON (250V) ⁄
8
-600A, General Purpose Fuses
Time-Current Curves - Average Melt
AMP RATING
300
100
10
1
0.1
0.01
CURRENT IN AMPS
0713
BU-SB13738
Page 2 of 4
Data Sheet # 1030
NON/NOS, 600/250Vac Class K5 & H
NOS (600V), 1-600A, General Purpose Fuses
Dimensions – in
All Diameters 0.008
5" ( 0.0ꢁ1ꢀ
1ꢁ.ꢁ8" ( 0.094ꢀ
11.6ꢁ" ( 0.094ꢀ
0.81" ( 0.008ꢀ
ꢁ.1ꢁ"
ꢂ.59"
1 to ꢁ0A
450 to 600A
5.5" ( 0.0ꢁ1ꢀ
1.06" ( 0.008ꢀ
ꢁ5 to 60A
ꢂꢂ5 to 400A
9.6ꢁ" ( 0.06ꢂꢀ
7.9" ( 0.06ꢂꢀ
Description: Basic protection 600V NOS Class K5 and H
general purpose, non-current-limiting, one-time fuses.
1.84"
1.ꢁ4"
110 to ꢂ00A
70 to 100A
Catalog Symbol: NOS-(amp)
Ratings:
Features:
Volts — 600Vac
• Protect lighting, heating and other circuits not subject to temporary
surges and where available short-circuit currents are relatively low
• NOS one-time fuses do not have any appreciable degree of time-
delay and thus should not be specified in circuits where large
transients or motor overloads occur. Use Bussmann advanced
protection FUSETRON™ LPS-R or ultimate protection Low-Peak™
LPS-RK dual-element, time-delay fuses.
• For general purpose circuits, size at amp rating of circuit
• For motor circuits, size at 300% to 400% according to the NEC®
motor ampacity tables 430.247 to 430.250, per 430.6(A)(1)
Amps — 1-600A
IR — 50kA Vac RMS Sym. (1-60A)
— 10kA Vac RMS Sym. (70-600A)
Agency Information:
CE, UL Listed, Class K5 (1-60A), Std. 248-9,
Class H (70-600A), Std. 248-6, UL Guide JDDZ, File E4273
CSA Certified, Class 1421-01, File 53787
Recommended Fuse Blocks
Catalog Numbers (amps)
Fuse Amps
0-30
1-Pole
2-Pole
3-Pole
NOS-1
NOS-2
NOS-3
NOS-4
NOS-5
NOS-6
NOS-7
NOS-8
NOS-9
NOS-40
NOS-45
NOS-50
NOS-60
NOS-70
NOS-75
NOS-80
NOS-90
NOS-100
NOS-110
NOS-125
NOS-150
NOS-175
NOS-200
NOS-225
NOS-250
NON-300
NOS-350
NOS-400
NOS-450
NOS-500
NOS-600
H60030-1
H60030-2
H60030-3
NOS-10
NOS-12
NOS-15
NOS-20
NOS-25
NOS-30
NOS-35
35-60
H60060-1
H60060-2
H60060-3
70-100
110-200
225-400
450-600
HM60100-1CR
HM60200-1CR
HM60400-1CR
HM60600-1CR
HM60100-2CR
HM60200-2CR
HM60400-2CR
HM60600-2CR
HM60100-3CR
HM60200-3CR
HM60400-3CR
HM60600-3CR
For additional information on 600 volt fuse blocks, see Data
Sheet # 1112 (H) and product brochure # 3192 (HM Series).
NOS 600V Carton Quantity and Weight
Amp Rating
1–30
35–60
Carton Qty.
Fuse Reducers For Class R Fuses
10
10
5
Equipment
Fuse Clips
60A
Desired Fuse
(Case) Size
30A
Catalog Numbers
(Pairs) 250V
NO.663
70–100
110–200
225–400
450–600
1
1
1
30A
60A
60A
100A
100A
200A
NO.216
NO.616
NO.626
NO.2621
NO.2641
NO.2642
100A
200A
200A
400A
For additional information on Class R fuse reducers, see
Data Sheet # 1118.
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information
contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
0713
BU-SB13738
Page 3 of 4
Data Sheet # 1030
NON/NOS Class K5 & H, 600/250Vac
NOS (600V), 1-600A, General Purpose Fuses
Time-Current Curves - Average Melt
AMP RATING
300
100
10
1
0.1
0.08
0.06
0.04
0.03
0.02
0.01
CURRENT IN AMPS
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information
contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
0713
BU-SB13738
Page 4 of 4
Data Sheet # 1030