LPN-RK-1/10SPNP [COOPER]
Electric Fuse, Time Delay Blow, 0.1A, 250VAC, 125VDC, 300000A (IR), Inline/holder;型号: | LPN-RK-1/10SPNP |
厂家: | COOPER BUSSMANN, INC. |
描述: | Electric Fuse, Time Delay Blow, 0.1A, 250VAC, 125VDC, 300000A (IR), Inline/holder 电路保护 |
文件: | 总3页 (文件大小:191K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Low Voltage, Branch Circuit Rated Fuses
Low-Peak® dual-element, time-delay fuses
Typical Applications
LPN-RK_SP (250V) Class RK1
• Large Distribution Switchboards
LPS-RK_SP (600V) Class RK1
• Power Panelboards
• Motor Control Centers
Now Available
With Optional
Indication
• Machinery Disconnect Switches
LPN Catalog Numbers (Amps) (250Vac/125Vdc)
1
1
LPN-RK- ⁄10SP
LPN-RK-3 ⁄
LPN-RK-4SP
LPN-RK-4 ⁄
LPN-RK-5SP
LPN-RK-5 ⁄10SP
LPN-RK-6SP
LPN-RK-6 ⁄
LPN-RK-8SP
LPN-RK-9SP
LPN-RK-10SP
LPN-RK-12SP
LPN-RK-15SP
LPN-RK-17 ⁄
LPN-RK-20SP
LPN-RK-25SP
LPN-RK-30SP
LPN-RK-35SP**
LPN-RK-40SP**
LPN-RK-45SP**
LPN-RK-50SP**
2
SP
LPN-RK-60SP**
LPN-RK-70SP****
LPN-RK-80SP**
LPN-RK-90SP**
LPN-RK-100SP**
LPN-RK-110SP**
LPN-RK-125SP**
LPN-RK-150SP**
LPN-RK-175SP**
LPN-RK-200SP**
LPN-RK-225SP**
LPN-RK-250SP**
LPN-RK-300SP**
LPN-RK-350SP**
LPN-RK-400SP**
LPN-RK-450SP**
LPN-RK-500SP**
LPN-RK-600SP**
15
LPN-RK- ⁄100SP
Specifications
Description:
2
1
LPN-RK- ⁄10SP
2SP
3
LPN-RK- ⁄10SP
Current-limiting, dual-element,
time-delay fuse; 10 seconds
(minimum) at 500% rated
amps (8 seconds for 0-30A
sizes). Now available with
optional permanent indication
on select ratings (see Catalog
Numbers table).
4
6
LPN-RK- ⁄10SP
1
LPN-RK- ⁄
2SP
6
1
LPN-RK- ⁄10SP
4SP
8
LPN-RK- ⁄10SP
LPN-RK-1SP
LPN-RK-1 ⁄
LPN-RK-1 ⁄
LPN-RK-1 ⁄10SP
LPN-RK-1 ⁄10SP
LPN-RK-1 ⁄10SP
LPN-RK-2SP
LPN-RK-2 ⁄
1
8
SP
1
4SP
Dimensions: See page 11 for Class RK1 dimensions.
Construction: Copper fuse element.
Ratings:
4
6
1
2SP
8
Volts LPN-RK:
— 250Vac (or less)
— 125Vdc (0-60A)
— 250Vdc (70-600A)
LPS-RK:
1
4
SP
1
LPN-RK-2 ⁄
LPN-RK-2 ⁄10SP
LPN-RK-3SP
2SP
8
2
LPN-RK-3 ⁄10SP
— 600Vac (or less)
— 300Vdc
*Meets all performance requirements of UL Standard 248-12 for Class RK1 fuses.
**Available with optional permanent indication. To order, place “I” at end of Catalog Number.
Example: LPN-RK-35SPI.
0-60A fuses available with Nickel plate option. (Ex: LPS-RK30SPNP) 70-600A fuses available
with Tin plate option. Example: LPS-RK-100SP-TP.
1
Amps — ⁄10-600A
IR — 300,000A RMS Sym.
— 100,000A dc
Agency Information: CE, UL Listed – Special Purpose*,
Guide JFHR, File E56412, CSA Certified (200,000 AIR),
Class RK1 per CSA C22.2, No. 248.12, Class 1422-02, File
53787.
LPS Catalog Numbers - (Amps) (600Vac/300Vdc)
1
1
LPS-RK- ⁄10SP
LPS-RK-2 ⁄
2
SP
LPS-RK-12SP**
LPS-RK-110SP**
LPS-RK-125SP**
2
8
LPS-RK- ⁄10SP
LPS-RK-2 ⁄10SP LPS-RK-15SP**
3
1
LPS-RK- ⁄10SP
LPS-RK-3SP
LPS-RK-17 ⁄
2
SP** LPS-RK-150SP**
4
2
LPS-RK- ⁄10SP
LPS-RK-3 ⁄10SP LPS-RK-20SP**
LPS-RK-175SP**
LPS-RK-200SP**
LPS-RK-225SP**
LPS-RK-250SP**
LPS-RK-300SP**
LPS-RK-350SP**
LPS-RK-400SP**
LPS-RK-450SP**
LPS-RK-500SP**
LPS-RK-600SP**
1
1
LPS-RK- ⁄
2
SP
LPS-RK-3 ⁄
2
SP
LPS-RK-25SP**
LPS-RK-30SP**
LPS-RK-35SP**
LPS-RK-40SP**
Features and Benefits
6
LPS-RK- ⁄10SP
LPS-RK-4SP
• Separate overload and short-circuit elements provide time
delay for close sizing of high inrush loads linked with K1
current-limitation and selective coordination ratio of 2:1
(within Low-Peak fuse family) prevents widespread
blackouts.
• Inventory consolidation of Class RK1, RK5 and H fuses for
reduced SKU investment and minimizing potential for
misapplying fuse.
• 300,000A RMS symmetrical interrupting rating provides
adequate ratings without obsolescence for all electrical
systems, big or small.
• Insulated end caps reduces exposure to live parts and
extends air gap to distance between blades of adjacent
mounted fuses or to housing.
8
1
LPS-RK- ⁄10SP
LPS-RK-4 ⁄
2
SP
LPS-RK-1SP
LPS-RK-5SP
1
6
LPS-RK-1 ⁄
8
SP LPS-RK-5 ⁄10SP LPS-RK-45SP**
1
LPS-RK-1 ⁄
4
SP LPS-RK-6SP** LPS-RK-50SP**
4
1
LPS-RK-1 ⁄10SP LPS-RK-6 ⁄
4
SP** LPS-RK-60SP**
1
LPS-RK-1 ⁄
2
SP LPS-RK-7SP** LPS-RK-70SP**
6
LPS-RK-1 ⁄10SP LPS-RK-8SP** LPS-RK-80SP**
8
LPS-RK-1 ⁄10SP LPS-RK-9SP** LPS-RK-90SP**
1
LPS-RK-2 ⁄
4
SP LPS-RK-10SP** LPS-RK-100SP**
*Meets all performance requirements of UL Standard 248-12 for Class RK1 fuses.
**Available with optional permanent replace fuse indication. To order, place “I” at end of
Catalog Number. Example: LPS-RK-15SPI.
Data Sheets: LPN-RK — 1003 (0-60) and 1004 (70-600)
LPN-RK with indication — 1066 (70-600)
LPS-RK — 1001 (0-60) and 1002 (70-600)
LPS-RK with indication — 1061 (0-60) and
1064 (70-600)
Recommended Fuse Holders & Blocks For Class RK1 600V
& 250VFuses
• See page 9
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
16
16
Low Voltage, Branch Circuit Rated Fuses
Low-Peak® dual-element, time-delay fuses
Time-Current Characteristic Curves—Average Melt
LPN-RK 250V
AMPERE RATING
15 20 30
60
100 200 400 600
LPN-RK 250V
AMPERE RATING
300
100
300
100
10
10
1
1
.1
.1
.01
.01
RMS SYMMETRICAL CURRENT IN AMPERES
CURRENT IN AMPERES
LPS-RK 600V
AMPERE RATING
20 30
300
60
100 200 400 600
LPS-RK 600V
AMPERE RATING
100
10
1
.1
CURRENT IN AMPERES
.01
CURRENT IN AMPERES
Recommended Fuse Holders & Blocks For Class RK1 600V
& 250VFuses
Data Sheets: LPN-RK — 1003 (0-60) and 1004 (70-600)
Data Sheets: LPS-RK — 1001 (0-60) and 1002 (70-600)
• See page 9
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
17
17
Low Voltage, Branch Circuit Rated Fuses
Low-Peak® dual-element, time-delay fuses
Current Limitation Curves—LPN-RK (250V)
B
400,000
100,000
Did You Know?
600
400
200
Manhattan’s Biggest Building Project
Protected by Cooper Bussmann®
Low-Peak® Fuses
100
60
10,000
30
New York City’s landmark
AOL Time Warner Center is
A
protected by a vast array of
1,000
Cooper Bussmann products.
The $1.7 billion, twin-towered,
glass-walled complex rises
RMS SYMMETRICAL CURRENTS IN AMPERES
A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS)
750 feet and measures 2.8
million square feet. The elec-
trical circuit protection system
has 25 switchboards (1200A -
Current Limitation Curves—LPS-RK (600V)
4000A) all containing fusible switches, 500 panel-
boards (100A – 1600A), 75 plug-in busway switches
(100A – 600A), and more than 1900 Cooper
Bussmann Class J Low-Peak® fuses. Cooper
Bussmann LPJ fuses were used because of the
superior series-ratings available using Class J fuses
with downstream circuit breaker panels.
B
Fuses were selected by the consulting engineer for
all switchboards, power panels and busway switches
because of the high available short circuit currents
and the need for selective coordination of
overcurrent protective devices (a requirement of the
New York City Electrical Code) so the electrical
system does not have a “blackouts.”
Recommended Fuse Holders & Blocks For Class RK1 600V
Data Sheets: LPN-RK — 1003 (0-60) and 1004 (70-600)
Data Sheets: LPS-RK — 1001 (0-60) and 1002 (70-600)
& 250VFuses
• See page 9
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
18
相关型号:
LPN-RK-100SP-TP
Electric Fuse, Time Delay Blow, 100A, 250VAC, 250VDC, 300000A (IR), Inline/holder
COOPER
LPN-RK-10SPNP
Electric Fuse, Time Delay Blow, 10A, 250VAC, 125VDC, 300000A (IR), Inline/holder
COOPER
©2020 ICPDF网 联系我们和版权申明