115S15VFI-Y [COOPER]
Analog Circuit,;型号: | 115S15VFI-Y |
厂家: | COOPER BUSSMANN, INC. |
描述: | Analog Circuit, |
文件: | 总4页 (文件大小:99K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
www.martekpower.com
100VFI series
FEATURES
Single & Dual Output
DC/DC Converter
• HIGH ISOLATION - 6000 VDC
• Up to 75 % Efficiency
• Single and Dual Output, 1.5 watt converter
• Available in 5, 12, and 15 VDC Inputs
• Short Circuit Protection
• Low Isolation Capacitance
INPUT CHARACTERISTICS
DESCRIPTIONS
Unit/Comments
Min Typ Max
The 100VFI Model 1.5 watt DC/DC’s are specially designed to
provide ultra-high levels of isolation 6000VDC in a low profile
24 pin DIP package. The series consists of 18 models with
input voltages of 5V, 12V and 15V, and offers regulated
output voltages of 5V, 12V, 15V, 5V, 12V and 15V.
Input Voltage
5 VDC Input Models
12 VDC Input Models
15 VDC Input Models
Input Fuse Requirements
5 VDC Input Models
12 VDC Input Models
15 VDC Input Models
VDC
VDC
VDC
4.5
5
5.5
10.8 12 13.2
13.5 15 16.5
mA;Slow blow type
mA;Slow blow type
mA;Slow blow type
Amp
mW
Pi Filter
1000
250
The 100VFI series is an excellent selection for railroad/
transportation equipment, medical equipment subsystems,
process/machine control equipment and automatic test
instrumentation.
250
Reverse Polarity Input Current
Short Circuit Input Power
Input Filter
0.5
1000
OUTPUT CHARACTERISTICS
Unit/Comments
% Output voltage at
nominal line & FL
% Equal Output
Loads
Min Typ Max
Output Voltage Set Point
±2.0 ±4.0
Output Voltage Balance
(Duals)
Line Regulation
±0.5 ±2.0
±1.2 ±1.5
%; % Change /
Percentage change
in Input
GENERAL CHARACTERISTICS
voltage
Load Regulation (5 Vout)
% Output voltage
measured from FL
to 20% load
±±.0 ±10.0
Min Typ Max Unit/Comments
Switching Frequency
Test Isolation Voltage
50
100
kHz
8,000
VDC, 1 minute
VDC, 1 minute
Mohm, 500VDC
Load Regulation (±5Vout)
Load Regulation (12,±12Vout)
Load Regulation (15,±15Vout)
Ripple/Noise
±8.0 ±12.0
±6.0 ±8.0
±4.0 ±6.0
30 40
Rated Isolation Voltage 6,000
Isolation Resistance
Isolation Capacitance
MTBF (MIL-HBK-21±F)
10,000
10 15 pF, 100kHz, 1Volt
Million Hours,
mV p-p, Nom.Line
@FL, 20MHz B.W.,
using 1 μf bypass
capacitor
mV p-p, Over Line,
Load & Temp., 20
MHz B.W.,
2
o
+25 C, Ground
Benign
Ripple/Noise
50
using 1 μf bypass
capacitor
%Rated Output Load
Continuous,
Overload Protection
Short Circuit Protection
120
Automatic Recovery
% per degree C
Temperature Coefficient
±0.01 ±0.02
Martek Power reserves the right to change specifications without notice.
>> B-17
1111 Knox Street Torrance CA 90502 USA Tel: +1 310 202 8820 sales@martekpower.com
www.martekpower.com
ENVIRONMENTAL SPECIFICATIONS
PHYSICAL CHARACTERISTICS
Min Typ Max Unit/Comments
Unit/Comments
o
-40
-55
+85 C; Ambient
1.25 X 0.8 X 0.4 inches
(31.8 X 20.3 X 10.2 mm)
Non-Conductive Black Plastic
UL94V-0
Operating Temp. Range
Storage Temp. Range
Relative Humidity
Case Size
o
+125 C
+95 % Humidity; non-
condensing
Case Material
Flammability
Weight
Free-Air Convection
12 Grams
Cooling
OUTLINE DRAWING
1.25 (31.8)
0.40
(10.2)
SIDE VIEW
0.15
(3.8)
0.020(0.50)
PIN DIA.
0.10
(2.5)
0.100
(2.54)
0.08 (2.0)
1
2
11 12
0.600 0.80
(15.22) (20.3)
BOTTOM VIEW
15 14 13
24 23
PIN OUT CHART
Pins
1
Single
+ Vin
Dual
Notes:
1. Unless otherwise specified dimensions are in inches (mm).
+ Vin
+ Vin
2
+ Vin
Tolerances
Inches
mm
11
12
13
14
15
23
24
+ Vout
+ Vout
- Vout
- Vout
No Pin
- Vin
+ Vout
+ Vout
Common
Common
- Vout
- Vin
X.XX = ±0.02
X.XXX= ±0.010
±0.002
X.X = ±0.5
X.XX = ±0.25
±0.05
Pin :
- Vin
- Vin
All specifications are typical at nominal input, nominal load and 25° C unless otherwise specified.
External, low ESR, 10 microfarad (minimum) capacitor across output is recommended for operation.
>> B-18
1111 Knox Street Torrance CA 90502 USA Tel: +1 310 202 8820 sales@martekpower.com
www.martekpower.com
HOW TO ORDER
HOW TO ORDER
Y
1 XX S XX VFI -
Wattage=1.5W
Output Voltage
ROHS Compliant
Series
Output
Configuration
(S=Single, D=Dual)
Nominal
Input Voltage
MODEL SELECTION CHART
Model
Nominal
Output
Voltage
(VDC)
Full Load
Output
Current
(mA)
300
No Load
Input
Current
(mA)
50
Full Load Reflected Efficiency
Input
Input
Current
(mA)
400
Ripple
Current
(mA)
30
@ FL
(%)
Voltage
(VDC)
5
105S5VFI
112S5VFI
115S5VFI
105D5VFI
112D5VFI
115D5VFI
105S12VFI
112S12VFI
115S12VFI
105D12VFI
112D12VFI
115D12VFI
105S15VFI
112S15VFI
115S15VFI
105D15VFI
112D15VFI
115D15VFI
5
±5
±5
±5
±5
±5
±5
±5
±5
±5
±5
±5
±5
±5
±5
±5
±5
±5
±5
5
12
125
50
400
30
5
15
100
50
400
30
5
±5
±150
±63
50
400
30
5
±12
±15
5
50
400
30
5
±50
50
400
30
12
12
12
12
12
12
15
15
15
15
15
15
300
30
16±
25
12
125
30
16±
25
15
100
30
16±
25
±5
±150
±63
30
16±
25
±12
±15
5
30
16±
25
±50
30
16±
25
300
30
133
20
12
125
30
133
20
15
100
30
133
20
±5
±150
±63
30
133
20
±12
±15
30
133
20
±50
30
133
20
>> B-19
1111 Knox Street Torrance CA 90502 USA Tel: +1 310 202 8820 sales@martekpower.com
www.martekpower.com
DERATING CURVES
MODEL 100VFI
Pout %
100
100LFM
400LFM
200LFM
90
80
±0
60
50
40
30
20
10
Natural
Convection
0
-40
50
60
±0
80
90
100
110
TEMPERATURE ° C