TYPE MS
ELECTROLYTIC
AC MOTOR START CAPACITORS
FEATURES:
ꢀ Moisture & Oil Resistant Plastic Case
ꢀ Insulated metal case
HIGH LIGHTS:
ꢀ Capacitance:
ꢀ Voltage:
21 - 1590 Mfd
110 Vac - 330 Vac
ꢀ UL recognized - File #E199307
ꢀ Long Life and High Reliability
ꢀ Optional Leads and Resistors
ꢀ Operating Frequency: 50 - 60 Hz
ꢀ Power Factor: 10% Max.
ꢀ Ambient Temperature: -40ꢀC +65ꢀC
APPLICATIONS:
Motor Starting and other intermittent AC applications
Proudly Made In U.S.A.
The MS motor start aluminum electrolytic capacitor is used to provide the torque necessary to start AC motors and can be used in other intermittent
AC applications. The capacitor comes in all popular styles with a variety of terminal configuration choices. Mallory Motor Start Capacitors are
designed in accordance with EIA-463-B. The metal case units are covered with a plastic sleeve (PVC) to provide electrical insulation.
p
ȭ
o
4411 South High School Road
Indianapolis,IN 46241
®
I
4
2
Phone: (317) 612-1000
(800) 625-4369
Fax: (317) 612-1010
MALLORY AC CAP
www.mallory-ac.com
Type MS
Standard Terminal Layouts & Resistor Layout
Inches
Millimeters
L
C
(Ref.)
C
(Ref.)
D
D
Case
Code
L
(+0.020, -0.030)
(ꢁ0.015)
(ꢁ0.38)
(+0.51, -0.76)
1
1
1
5
5
7
7
7
1
2
3
4
5
6
7
8
1-7/16 (1.4375)
1-7/16 (1.4375)
1-7/16 (1.4375)
1-13/16 (1.8125)
1-13/16 (1.8125)
2-1/16 (2.0625)
2-1/16 (2.0625)
2-9/16 (2.5625)
2-3/4
3-3/8
4-3/8
3-3/8
4-3/8
3-3/8
4-3/8
4-3/8
(2.750)
(3.375)
(4.375)
(3.375)
(4.375)
(3.375)
(4.375)
(4.375)
/
2
/
2
/
2
/
8
/
8
/
8
/
8
/
8
(.500)
36.51
36.51
36.51
46.04
46.04
52.39
52.39
65.09
69.85
85.73
111.13
85.73
111.13
85.73
111.13
111.13
12.70
12.70
12.70
15.88
15.88
22.23
22.23
22.23
(.500)
(.500)
(.625)
(.625)
(.875)
(.875)
(.875)
Standard
Solder Lug Terminals
(SL)
Dual Disconnect Terminals
W/Solder Lug Terminal
(DQCS)
Single Disconnect Terminals
(SQC)
Dual Disconnect Terminals
(DQC)
(All Cases)
(All Cases)
(All Cases)
(Case 4, 5, 6, 7 & 8 only)
.125
(Ref)
C
C
C
C
.0625
(Ref)
.0625
(Ref)
.0625
(Ref)
L
D
Mounting Accessories
HB Brackets
PL and PLA End Caps
Catalog Number
Dimensions (Ref.)
EIA
Case Code
A
EIA
Case Code
Wire Hole
Wire Hole
A
B
C*
D
Dimension
Toward Bracket Away From Bracket
HB2
HB4
HB8
1
3-3/8"
1-11
1-13
2-23
/
/
/
"
7/8"
1-1/2"
1-25
1.258
PL3
PL6
PL8
PL10
PLA3
PLA6
PLA8
PLA10
1-2-3
4-5
6-7
8
1-7/16
1-13
"
64
2-4-6
3-5-7-8
4-1/64
5-1/64
"
"
"
16
1-37
/ "
64
/
"
16
"
32
/
"
2-5/64
"
2-1/16
2-9/16
"
32
"
Material: .042 spring steel
with black parkerized finish.
* Center-to-center dimension.
.2188 R
.3125 R
PL
.375
A
.750
.9375 Space
D
.191 R
.094
1.375
*C
PLA
.375
.234
B
A
A
.875
1.1875
HB brackets are used with PL or PLA end caps. The bracket is assembled to the motor or any suitable surface by two screws in line at any convenient position within
the center-to-center dimension (C) shown in the chart. The PL end cap is placed in position and the entire assemby snapped into place with the connecting wires
brought through the bracket hole. Use PLA style caps if the wire is to be direced away from the bracket. (Example: PLA3).
End caps and brackets are shipped loose and should be ordered separately.
Contact the factory for information about wire leads and sub-assemblies.
Mallory AC Capacitor LLC - 4411 South High School Road - Indianapolis IN 46241 - Phone: (317)612-1000 - Fax: (317)612-1010 - www.mallory-ac.com
2
Ratings Charts
MSA - Type 2 Standard Duty Ratings
MSB - Type 1 Heavy Duty Ratings
EIA-463-B does not specify case sizes for Type 1
Case sizes listed are available from Mallory
Highlighted case sizes per EIA-463-B
Other case sizes listed are available from Mallory
and also meet EIA-463-B Type 2 test specifications.
and also meet EIA-463-B Type 1 test specifications.
MFD
110 Vac 125 Vac 165 Vac 220 Vac 250 Vac 330 Vac
MFD
110 Vac
125 Vac
165 Vac
220 Vac 250 Vac
330 Vac
21-25
25-30
1
1
1
1
1
1
1
1
1
1
1 or 2
1 or 2
1 thru 4
1 thru 4
2 thru 4
2 thru 4
3 thru 5
4 or 5
4 or 5
4 thru 7
4 thru 8
4 thru 8
5 thru 8
5 thru 8
5 thru 8
7 or 8
7 or 8
7 or 8
7 or 8
7 or 8
8
21-25
1
1
1
1
1
1
25-30
1
1
1
1
1
1 or 2
30-36
1
1
1
1
1 or 2
1 or 2
1 or 2
1 or 2
1 thru 4
1 thru 4
1 thru 4
2 thru 5
4 or 5
4 or 5
4 or 5
4 thru 7
4 thru 7
4 thru 8
5 thru 8
5 thru 8
5 thru 8
5 thru 8
7 or 8
7 or 8
7 or 8
7 or 8
8
30-36
36-43
1
1
1
1
1
1
1
1
1
2
2
2
36-43
43-52
1
1
1
1
1
1
1
1 or 2
1 or 2
1 or 2
1 thru 4
1 thru 4
1 thru 4
1 thru 4
2 thru 5
2 thru 5
2 thru 7
4 thru 7
4 thru 7
4 thru 8
4 thru 8
4 thru 8
4 thru 8
7 or 8
7 or 8
7 or 8
7 or 8
8
43-52
47-56
1
1
1
1
1
1
1
1
2
2
4
4
47-56
53-64
1
1
1
1
1
1
53-64
64-77
1
1
1
1
1
1
1 or 2
4
3 or 4
4
4
4
64-77
1
1
1
72-87
1
1
1
1
1
72-87
1
1
1
4
4
4 or 5
88-106
108-130
124-149
130-156
145-174
161-193
189-227
216-260
233-280
243-292
270-324
324-389
340-408
378-455
400-480
430-516
460-552
540-648
590-708
645-774
708-850
720-864
800-960
815-978
829-995
850-1020
1 or 2
1 or 2
1 or 2
2 thru 4
2 thru 4
2 thru 4
2 thru 4
2 thru 4
2 thru 5
2 thru 5
2 thru 5
4 thru 7
4 thru 7
4 thru 7
4 thru 7
4 thru 8
4 thru 8
4 thru 8
5 thru 8
5 thru 8
5 thru 8
5 thru 8
7 or 8
7 or 8
7 or 8
7 or 8
7 or 8
7
88-106
1
1
1
1
1
1
4
4
4 or 5
5
5
5
6
7
8
8
8
8
8
8
1
1
1
1
1
108-130
124-149
130-156
145-174
161-193
189-227
216-260
233-280
243-292
270-324
324-389
340-408
378-455
400-480
430-516
460-552
540-648
590-708
645-774
708-850
720-864
800-960
815-978
829-995
850-1020
1000-1200
1020-1224
1175-1410
1280-1536
1326-1590
5
5
5
5
7
7
7
8
8
8
8
8
8
8
8
1
1
1
1
1
1
5
5
1
1
1
1
1
2
5 thru 7
1
1
1
1
1
1
2
5 thru 7
7 or 8
1
1or 2
1 or 2
1 or 2
1 thru 3
1 thru 3
3 or 4
1 or 2
1 or 2
1 or 2
1 or 2
2
2
2
2
3 or 4
3 or 4
7
7
8
8
8
8
8
8
8
8
2 or 3
2 or 3
2
2
3 or 4
3 or 4
1 thru 3 2 thru 4
1 thru 4 2 thru 4
2 thru 4 2 thru 4
2 thru 4 2 thru 4
2 thru 4 2 thru 4
2 thru 4 2 thru 4
3 or 4
3 or 4
4 or 5
8
3 or 4
3 or 4
3 or 4
3 or 4
4 or 5
5 thru 7
8
8
3 or 4
4
4
4
5 thru 7
5 thru 7
8
8
8
8
4
4
5 thru 7
4 or 5
4 or 5
4 or 5
4 or 5
8
8
5
5
5 thru 7
8
8
8
5 or 6
5 or 6
7
7
7
7
8
8
8
8
8
8
8
8
4 thru 7 4 thru 7
4 thru 7 4 thru 7
4 thru 7 4 thru 7
4 thru 7 4 thru 7
4 thru 7 4 thru 8
4 thru 8 5 thru 8
4 thru 8 5 thru 8
5 or 6
5 or 6
6 or 7
6 or 7
5
7
7
7
7
7
7
8
8
8
6 or 7
7
7
7
7
7
7
8
8
8
1000-1200 5 thru 8 5 thru 8
1020-1224 5 thru 8 5 thru 8
1175-1410 5 thru 8 5 thru 8
1280-1536 5 thru 8
1326-1590
7
7
7
Part Number Nomenclature
MS
A
1
R
10
161
N
Standard Part Number
Mallory Type Designation
Identifies the basic capacitor design;
Performance
A = EIA Type 2
B = EIA Type 1 S = Special
Case Code
(See standard ratings page)
Case Type
R = Recessed (Standard).
Voltage Rating
10 = 110
22 = 220
12 = 125
25 = 250
16 = 165
33 = 330
Minimum Capacitance
Expressed in microfarads.
Always 3 or 4 digits.
Resistor
N = No resistor (Standard)
R = With Resistor (15kꢂ, 2 Watt is standard)
Mallory AC Capacitor LLC - 4411 South High School Road - Indianapolis IN 46241 - Phone: (317)612-1000 - Fax: (317)612-1010 - www.mallory-ac.com
3
Metal Case AC Motor Start Capacitors
Maximum Capacitance for Aluminum Case Designs
per EIA ratings Type 2
D
x L
C
Case Code
(mm)
(mm)
110 Vac
125 Vac
165 Vac
220 Vac
250 Vac
330 Vac
A1
A2
A3
B2
B3
C2
C3
C4
D2
D3
D4
E3
E4
25
25
25
30
30
35
35
x
x
x
x
x
x
x
45
10.16
10.16
10.16
10.16
10.16
12.7
161
243
145
189
108
130
189
189
270
270
378
540
400
540
800
645
1000
61
75
61
75
61
75
324
270
108
108
161
161
233
324
216
270
430
378
540
324
270
460
400
460
430
72
108
161
124
161
243
216
270
53
72
12.7
645
590
35 x 101
12.7
850
850
108
88
40
40
x
x
61
75
15.9
590
590
15.9
850
829
108
161
145
189
40 x 101
45 75
45 x 101
15.9
1280
1020
1500
1175
1020
1410
x
15.9
15.9
Insulation hi-pot test is 2000 Vac between metal case and metal foil
wrapped around sleeve for 1 second.
L ꢁ 2.0
7.7mm Max.
7.7mm Max.
C ꢁ 0.5
D ꢁ 1.0
C
ꢁ0.5
Solder Lug Terminals
(SL)
(25,30mm Cases)
Standard Dual Disconnect Terminals
(DQC)
(35,40,45mm Cases)
Note: Add 1.0mm maximum to diameter and 1.0mm
maximum to length for PVC insulation sleeve.
Metal Case Part Number Nomenclature
MS
L
189
D
110
A2
N
3
Standard Part Number
Mallory Type Designation
Performance
L = EIA Type II
(Standard)
M = EIA Type I
(Special)
Contact Mallory for size information.
G = Extended Run (Special)
Minimum Capacitance
Expressed in Microfarad
Always in 3 or 4 Digits
Tolerance
D = -0 + 20%
Voltage Rating
3 Digits
Case Code
(See Table)
Resistor
N = No resistor (Standard)
R = With Resistor (15kꢂ, 2 Watt is standard)
Sleeve
3 = Blue PVC
Mallory AC Capacitor LLC - 4411 South High School Road - Indianapolis IN 46241 - Phone: (317)612-1000 - Fax: (317)612-1010 - www.mallory-ac.com
4
Application Guide for Plastic and Metal Case
Figure A:Type 2 (MSA)
Figure B:Type 1 (MSB)
Capacitance Rating
(mfd)
Duty Cycle
Capacitance Rating
(mfd)
Duty Cycle
ꢂ
ꢁ
Rated
Voltage Test
Volts AC (rms)
Rated
Voltage Test
Volts AC (rms)
Duration of test
(no. of starts)
Duration of test
(no. of starts)
Secs.
(On)
Secs.
(Off)
Secs.
Secs.
(Off)
(On)
From
To
From
To
3
/
3
/
110
21-25
130-156
270-324
400-480
590-708
1000-1200
21-25
108-130
161-193
243-292
400-480
645-774
21-25
124-149
243-292
378-454
540-648
850-1020
1326-1590
88-106
145-174
233-280
378-454
590-708
1326-1890
88-106
291/4
291/4
291/4
291/4
291/4
291/4
291/4
291/4
291/4
291/4
291/4
291/4
59
59
59
59
59
59
59
89
89
89
59
59
89
89
119
59
59
59
75,000
75,000
75,000
75,000
75,000
75,000
75,000
75,000
75,000
75,000
75,000
75,000
40,000
40,000
40,000
40,000
40,000
40,000
40,000
33,500
33,500
33,500
40,000
40,000
33,500
33,500
25,000
40,000
40,000
40,000
33,500
25,000
110
21-25
130-156
270-324
400-480
590-708
1000-1200
21-25
108-130
161-193
243-292
400-480
645-774
21-25
124-149
243-292
378-454
540-648
850-1020
1326-1590
88-106
145-174
233-280
378-454
590-708
1326-1890
88-106
291/4
59
89
119
179
239
291/4
59
50,000
50,000
33,500
25,000
16,500
12,500
50,000
50,000
33,500
25,000
16,500
12,500
33,500
33,500
25,000
16,500
12,500
33,500
33,500
25,000
16,500
12,500
33,500
33,500
25,000
16,500
12,500
33,500
33,500
25,000
16,500
12,500
4
4
3
/
1
1
1
1
1
4
3
/
4
3
/
4
3
/
4
3
/
4
3
/
3
125
/
4
125
4
3
/
4
1
1
1
1
3
/
4
89
3
/
4
119
179
239
59
3
/
4
3
/
4
1
1
165
220
250
330
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
165
220
250
330
108-130
130-156
233-280
378-454
21-25
124-149
216-259
340-408
850-1020
43-52
108-130
130-156
233-280
378-454
21-25
124-149
216-259
340-408
850-1020
43-52
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
89
119
179
239
59
37-56
72-86
37-56
72-86
89
88-106
161-193
270-324
21-25
36-43
72-86
108-130
216-259
21-25
25-30
36-43
145-174
243-292
460-552
30-36
64-77
88-106
189-227
430-516
21-25
30-36
64-77
88-106
161-193
270-324
21-25
36-43
72-86
108-130
216-259
21-25
25-30
36-43
145-174
243-292
460-552
30-36
64-77
88-106
189-227
430-516
21-25
30-36
64-77
119
179
239
59
89
119
179
239
59
89
119
179
239
72-86
108-130
88-106
270-324
89
119
72-86
108-130
88-106
270-324
ꢁ The number of starts shown are reduced starts for accelerated
testing so that test time does not exceed 35 days. Type 2 capaci-
tors should be capable of 50,000 starts for ratings to 125 volts
and 40,000 starts for higher voltages. See section 3.0 for testing
procedures.
ꢂ The number of starts shown are reduced starts for accelerated
testing so that test time does not exceed 35 days. Type 1 capaci-
tors should be capable of 75,000 starts for ratings to 125 volts
and 40,000 starts for higher voltages. See section 3.0 for testing
procedures.
If an application exceeds the duty cycles in Figure B, other meth-
ods of capacitor selection must be used, Contact Mallory for
assistance.
1.1 VOLTAGE RATING
1.2 CAPACITANCE RATING
The rated voltage of the capacitor must be greater than or equal
to the average voltage across the capacitor terminals during the
motor starting cycle. This is not necessarily the same as the mo-
tor line voltage. In addition, the cutoff voltage rating of the ca-
pacitor must be greater than or equal to the maximum voltage
attained across the terminals of the capacitor in actual service.
The maximum recommended cut-off voltages for the seven stan-
dard voltage ratings are as follows:
The capacitance is chosen to give the necessary starting torque
to the motor. The minimum capacitance value is the minimum
designed capacitance. The maximum capacitance is 20% more
than that value.
1.3 DUTY CYCLE
The duty cycle should be calculated for each application. It is the
ratio of the time the capacitor is on voltage to the total time of one
cycle. The duty cycles for the normal performance of Type 2
(MSA) capacitors are listed in Figure A. Mallory Type MSA
capacitors may be used in any intermittant application within their
temperature and voltage range where the duty cycle does not ex-
ceed that listed in the table in Figure A. This is in accordance
with the standards in EIA-463-B for Type 2 capacitors.
If a particular application exceeds the normal duty cycle, but does
not exceed the values listed in Figure B, an extra performance or
Type 1 (MSB) capacitor is required.
Rated
Maximum
Voltage (rms) Cut-Off Voltage (rms)
110
125
165
220
250
330
140
160
210
280
300
400
These ratings are based on the maximum capacitor temperature
of 65ꢀC.
(Continued)
Mallory AC Capacitor LLC - 4411 South High School Road - Indianapolis IN 46241 - Phone: (317)612-1000 - Fax: (317)612-1010 - www.mallory-ac.com
5
Application Guide (Continued)
1.4 Frequency
1.7 SAFETY
These capacitors are engineered for 60 Hz application but may Because the watt-second value of these capacitors is high, pre-
be operated between 47 Hz and 60 Hz without damage provided cautions should be taken during the testing and application of
voltage limitations stated above are observed. For other varia- these devices.
tions in frequency, contact Mallory.
Discharge resistors should be specified when there is a possibil-
ity of a residual charge left on the capacitor or to protect contacts.
Mis-application, such as exceeding design limits or applying
continuous AC voltage, may result in destruction or explo-
sion of capacitors.
1.5 MOUNTING
Vertical mounting of the capacitor with the terminals up is
recommended. However, horizontal mounting is acceptable pro-
viding the vent is located in the up position. Vertical mounting
with the terminals down is not recommended because the capaci-
tor life may be reduced and the operation of the pressure relief
vent impaired.
1.6 SOLVENTS
Solvent residues on the capacitors after cleaning may penetrate
the seal and cause internal corrosion resulting in shortened life.
Alcohol or water detergent cleaning is not usually harmful but
halogenated cleaning solvents are not recommended and should
be avoided.
Procedure for Capacitance and Power Factor Measurement
Type MS motor start capacitors are intended for intermittent duty application. The capacitance and power factor should be measured
by a Power Analyzer or referenced to the voltmeter, ammeter and wattmeter (impedance) method described as follows.
Capacitance is calculated by the following formula
when frequency is 60 Hertz.
Switch
I
W
2652 x Amps
Capacitance (ꢃF) =
Rated (Applied) Volts
Capacitor
Under Load
AC
Line
V
Power factor is calculated as follows:
Watts
% Power factor =
x 100
Volts x Amps
WARNING: Voltage should not be applied for more than 4 seconds to prevent over-heating of the capacitor
and incorrect measurements. Test with capacitor in upright position (contacts up) to allow proper function-
ing of safety vent. Over heating of any capacitor may result in sudden expulsion of hot flammable material.
Enclose the capacitor under test to prevent injury to persons in the event of abnormal capacitor failure.
All measurements are referenced to 25ꢀC (77ꢀF). Capacitors just brought in from the cold or recently tested (hot) must be allowed
to stabilize to room temperature (3-4 hours)
Other methods of capacitance and power factor measurement may result in erroneous readings.
For further information or help call Mallory AC Capacitor LLC at: (270) 678-4919
Mallory AC Capacitor LLC - 4411 South High School Road - Indianapolis IN 46241 - Phone: (317)612-1000 - Fax: (317)612-1010 - www.mallory-ac.com
6
Performance Characteristics
2.1 TEMPERATURE
2.7 CASE INSULATION TEST
2.1.1 OPERATING: These capacitors are designed to operate The capacitors shall be capable of withstanding the application
within the ambient temperature range of -40ꢀC to +65ꢀC.
of 1500 volts ac rms 60 Hz for 5 seconds between the terminals
2.1.2 STORAGE: These capacitors may be subjected, with and a metal foil tightly surrounding the lateral surface of the
out permanent damage, to conditions in transit where tempera- plastic case or insulating sleeve without breakdown or flash-
tures range from -55ꢀC to +95ꢀC.
over.
2.1.3 TOLERANCE: Unless otherwise specified, temperature
tolerance shall be ꢁ3ꢀC.
2.8 OVERVOLTAGE TEST
Capacitors shall be capable of withstanding the application of
140 percent of rated voltage ac rms 60 Hz for one second at room
temperature conditions without breakdown or visible damage to
them.
2.2 FREQUENCY
Unless otherwise specified, frequency shall be 50-60 Hz.
2.3 VOLTAGE RATING
2.9 VENT TEST
The rated voltage is the rms value of AC voltage at which the
capacitor may be operated at its normal duty cycle and maximum Capacitors shall be capable of releasing any excessive internal
ambient temperature.
pressure without violent expulsion of capacitor element or cover
or emission of flame, when rated ac rms voltage 60 Hz is applied
continuously to a capacitor. Care should be taken to shield the
capacitor from observers to prevent injury.
2.4 CAPACITANCE AND POWER FACTOR
The capacitance and power factor are measured by the voltage,
current, power method with 60 Hz sinusoidal rated voltage ap-
plied to the capacitor at standard conditions per EIA-463-B, Para-
3.0 ACCELERATED LIFE TEST
graph 9. Whenever voltage is applied, there is the possibility Capacitors shall be capable of withstanding life test in a 65ꢀC
the capacitor may vent. Care should be taken to shield the ꢁ3ꢀC ambient at rated sinusoidal voltage and frequency with cur-
capacitor from observers to prevent injury during testing.
rent limiting and discharge resistors. A resistance equivalent to
approximately 10% of the capacitor impedance shall be connected
in series with each capacitor and a resistor of approximately 1000
ohms shall be connected in parallel with each capacitor. Life test
shall be conducted in a test chamber with capacitors separated by
at least 1 inch of air and with sufficient circulation so that the
ambient temperature remains within the above temperature lim-
its and does not vary more than ꢁ1ꢀC. Also capacitors shall not
be exposed to direct radiation from heating elements.
2.5 TERMINAL STRENGTH
The capacitance terminals shall be capable of withstanding a
steady pull of 10 pounds applied gradually in any direction for a
period of 10 seconds. There shall be no loosening of the termi-
nals or damage to the terminals or seal. Atorque of 4 inch-pounds
applied to the terminals shall not cause them to rotate.
Test voltage is applied to the capacitor resistor combination. Spe-
cial test conditions for Type 1 and Type 2 capacitors are given in
the tables in section 1.3. At the conclusion of the life test, at
room temperature, the capacitance shall not differ from the initial
measured value by more than ꢁ25% and the power factor shall
not exceed 20%.
2.6 VIBRATION
Capacitors shall be clamped rigidly to a vibration platform and
subjected to a simple harmonic motion having a maximum
peak-to-peak amplitude of .06 inches and a maximum accelera-
tion of 10g. The frequency of vibration shall be varied linearly
between 10 and 55 cycles per second. The entire frequency
range, 10 to 55cps, shall be traversed in one minute.
Capacitors shall be vibrated for 1 hour with the direction of mo-
tion be in parallel to the axis of the capacitor. The capacitors
shall then be placed so that the direction of motion is perpendicu-
lar to the axis and the vibration continued for one hour.
There shall be no evidence of loosening of the capacitor element
within the container, when shaken by hand following the test.
There shall be no indication of intermittent contact during the 3
minute observation period. Capacitors shall not be open or
shorted.
The information contained herein is believed to be correct, but no guarantee or warranty, express or implied, with respect to accuracy, completeness or results is extended
and no liability is assumed. Nothing herein is to be construed as advising or authorizing practice of any invention covered by existing patent rights owned by Mallory or
others without license from the owners thereof. In the interest of improved design and performance, Mallory reserves the right to make changes in any specification, data
or material contained herein.
Mallory AC Capacitor LLC - 4411 South High School Road - Indianapolis IN 46241 - Phone: (317)612-1000 - Fax: (317)612-1010 - www.mallory-ac.com
7
ȭ
Mallory AC Capacitor LLC
Customer Service
4411 South High School Road
Indianapolis,IN 46241
Phone: (317) 612-1000
(800) 625-4369
Fax: (317) 612-1010
Manufacturing Facility
Sales, Marketing & Engineering
2601 Happy Valley Road
Glasgow KY 42141
Phone: (270) 678-4919
(800) 678-1934
Fax: (270) 678-2032
www.mallory-ac.com
May 2003
TAG MS00
相关型号:
MSA3R16233N
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, NON-POLARIZED, 233uF, CHASSIS MOUNT, RADIAL LEADED, CAN
CDE
©2020 ICPDF网 联系我们和版权申明