ICB12S30F04A2IO [CARLOGAVAZZI]
ICB12, ICB18 & ICB30 IO-Link 3-wire DC;型号: | ICB12S30F04A2IO |
厂家: | Carlo Gavazzi |
描述: | ICB12, ICB18 & ICB30 IO-Link 3-wire DC |
文件: | 总18页 (文件大小:2850K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
New generation inductive proximity sensors with IO-Link communication
Benefits
• A complete family. Available in M12, M18 and M30
robust nickel-plated brass housings with an operating
distance of 4 to 22 mm.
• Less machine downtime. Lower risk of mechanical
damage thanks to the extended operating distance.
• Easy to install. ICB sensors have a milled section for
wrench grip and two different thread lengths. The user
can choose between 2 m PVC cable and M12-disconnect
plug versions.
• High precision. The onboard advanced microcontroller
ensures better stability with respect to environmental
influences, with highly reliable repeatable measurements
between -25 and +70°C.
• Easy customization to specific OEM requests:
different cable lengths and materials, special labelling,
customized pig-tail solutions with special cables and
connectors are possible on request.
• The output can be operated either as a switching output
or in IO-Link mode.
• Fully configurable via IO-Link v1.1. Electrical outputs
can be configured as PNP/NPN/Push-pull, normally
open or normally closed.
Description
The new generation ICB series is a complete
family of high performance inductive sensors for
contactless and wear free detection of metallic
objects in industrial automation applications, such
as packaging, materials handling and machine
tools. The advanced electronics is enclosed in a
robust nickel-plated brass housing. It is available
in three diameters: M12, M18 and M30 with an
extended sensing distance range between 4 and
22 mm.
• Timer functions can be set, such as switch-on and
switch-off delay
• Adjustable sensing distance and hysteresis: sensing
distance can be set to 33%, 50%, 75% or 100% of the
maximum sensing distance
• Temperaturemonitoring:overorunder-runtemperature
alarms can be set
•
On-board IO-Link communication opens up many
possibilities, such as easy configuration and set-
up of the devices and advanced parameter setting.
Applications
• Non contact detection of metal objects in general position-sensing and presence-sensing in industrial applications
• Particularly suitable for rotational speed monitoring thanks to the high operating frequency
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
1
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
Main functions
• Integrated diagnostic function with flashing LED in the event of a short circuit or overload
• The devices can be operated in IO-Link mode once connected to an IO-Link master, or in standard I/O mode.
• In IO-Link mode the switching signals of the sensor are made available in the process data via the IO-Link interface.
• Several sensor functions can be set via the IO-Link interface:
► Adjustable switching distance: 33%, 50%, 75% or 100% of the maximum switching distance.
► Adjustable hysteresis: standard or increased value.
► Divider function: the sensor gives a signal after a specified number of actuation pulses has been
reached.
► Switch-on delay: the switching pulse is generated after the sensor actuation.
► Switch-off delay: the generation of the switch signal is delayed by the set time after sensor actuation.
► Temperature error: temperature is out of specifications.
► Temperature over-run and under-run: temperature is out of the limits defined by the user.
References
Order code
I C B
I O
Enter the code option instead of
Code
Option Description
I
C
B
-
-
-
Inductive sensor
Cylindrical housing with threaded barrel
Nickel-plated brass housing
M12 housing
M18 housing
M30 housing
Short housing with thread length of 30mm
Long housing with thread length of 50mm
Flush
12
18
30
S30
L50
F
N
Non-flush
-
Sensing distance [mm] E.g. 04 = 4mm; 14 = 14mm
ICB12 flush: 4mm
ICB12 non-flush: 8mm
ICB18 flush: 8mm
ICB18 non-flush: 14mm
ICB30 flush: 15mm
ICB30 non-flush: 22mm
04 or 08
08 or 14
15 or 22
M1
A2
-
M12 plug
2 m PVC cable
IO-Link programmable version
IO
Additional characters can be used for customized versions.
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
2
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
Selection guide
ICB12
Detec-
Con-
nec-
tion
Body
style
tion
princi-
ple
Rated operating dis-
tance Sn
Output type
Ordering no.
Cable
Plug
Cable
Plug
Cable
Plug
Cable
Plug
ICB12S30F04A2IO
ICB12S30F04M1IO
ICB12S30N08A2IO
ICB12S30N08M1IO
ICB12L50F04A2IO
ICB12L50F04M1IO
ICB12L50N08A2IO
ICB12L50N08M1IO
Flush
Short
Long
Non-
flush
Configurable: 33%, 50%,
75% or 100% of the
maximum Sn
Configurable: NPN/PNP/push-pull
NO/NC
Factory setting: PNP, NO
Flush
Factory setting: 100%
Non-
flush
ICB18
Detec-
tion
princi-
ple
Con-
nec-
tion
Body
style
Rated operating dis-
tance Sn
Output type
Ordering no.
Cable
Plug
Cable
Plug
Cable
Plug
Cable
Plug
ICB18S30F08A2IO
ICB18S30F08M1IO
ICB18S30N14A2IO
ICB18S30N14M1IO
ICB18L50F08A2IO
ICB18L50F08M1IO
ICB18L50N14A2IO
ICB18L50N14M1IO
Flush
Short
Long
Non-
flush
Configurable: 33%, 50%,
75% or 100% of the
maximum Sn
Configurable: NPN/PNP/push-pull
NO/NC
Factory setting: PNP, NO
Flush
Factory setting: 100%
Non-
flush
ICB30
Detec-
tion
princi-
ple
Con-
nec-
tion
Body
style
Rated operating dis-
tance Sn
Output type
Ordering no.
Cable
Plug
Cable
Plug
Cable
Plug
Cable
Plug
ICB30S30F15A2IO
ICB30S30F15M1IO
ICB30S30N22A2IO
ICB30S30N22M1IO
ICB30L50F15A2IO
ICB30L50F15M1IO
ICB30L50N22A2IO
ICB30L50N22M1IO
Flush
Short
Long
Non-
flush
Configurable: 33%, 50%,
75% or 100% of the
maximum Sn
Configurable: NPN/PNP/push-pull
NO/NC
Factory setting: PNP, NO
Flush
Factory setting: 100%
Non-
flush
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
3
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
Structure
ICB12
A
B
C
D
E
A
B
C
D
A
B
C
D
E
Element
Component
Sensing face
2 nuts
Function
A
B
C
Flush or non-flush
For sensor mounting
For wrench grip
Milled section
Green and Yellow LED: Output flashing: short
circuit or overload indication
For plug versions only
D
E
LED
M12 x 1, 4 pin, male connector
ICB18
A
B
C
D
E
A
B
C
D
A
B
C
D
E
Element
Component
Sensing face
2 nuts
Function
A
B
C
Flush or non-flush
For sensor mounting
For wrench grip
Milled section
Green and Yellow LED: Output flashing: short
circuit or overload indication
For plug versions only
D
E
LED
M12 x 1, 4 pin, male connector
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
4
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
ICB30
A
B
C
D
A
B
C
A
B
C
D
Element
Component
Sensing face
2 nuts
Function
Flush or non-flush
For sensor mounting
A
B
Green and Yellow LED: Output flashing: short
circuit or overload indication
For plug versions only
C
D
LED
M12 x 1, 4 pin, male connector
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
5
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
Sensing
Detection
Rated operating distance Sn
4 to 22 mm: depending on housing diameter and version (flush or non-flush)
The operating distance is measured according to IEC 60947-5-2, using a
standard target moving axially.
This target is square shape 1 mm thickness, made of steel e.g. type Fe 360
as defined in ISO 630 and it shall be of the rolled finish.
The length of the side of the square is equal to
Reference target
– the diameter of the circle inscribed on the active surface of the sensing face,
or
– three times the rated operating distance Sn whichever is greater
Assured operating sensing distance
(Sa)
0 ≤ Sa ≤ 0.81 x Sn (e.g. with Sn of 4 mm, Sa is 0 ... 3.24 mm)
Effective operating distance (Sr)
Usable operating distance (Su)
Hysteresis (H)
0.9 x Sn ≤ Sr ≤ 1.1 x Sn
0.9 x Sr ≤ Su ≤ 1.1 x Sr
1...20%
S
S: sensor
T: target
Y
X
T
Distance [Inches]
0,04 0,08 0,12 0,16 0,2
Distance [Inches]
0,02 0,04 0,06 0,08 0,1
0
0,24 0,28 0,32
-0,02
0
0,12 0,14 0,16
0,55
0,37
0,18
0
8
6
4
2
0
0,31
0,21
0,1
12
8
T
T
4
0
S
0
S
-2
-4
-6
-8
-0,11
-0,21
-0,32
-4
-8
-12
-0,18
-0,37
-0,55
-0,5
0
0,5
1
1,5
2
2,5
3
3,5
4
4,5
0
1
2
3
4
5
6
7
8
Distance [mm]
Distance [mm]
Fig. 1 M12 Flush
Fig. 2 M12 Non-flush
Distance [Inches]
Distance [Inches]
-0,2 -0,1
24
0
0,1
0,2
0,3
0,4
0,5
0,6
-0,02 0,02 0,06 0,1
0,14 0,18 0,22 0,26 0,3
0,55
0,37
0,18
0
0,76
12
16
8
8
4
0,38
0
T
T
0
0
S
S
-4
-8
-0,18
-0,37
-0,55
-8
-0,38
-0,76
-16
-24
-12
0
1
2
3
4
5
6
7
8
-4
-2
0
2
4
6
8
10
12
14
Distance [mm]
Distance [mm]
Fig. 3 M18 Flush
Fig. 4 M18 Non-flush
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
6
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
Distance [Inches]
-0,04 0,04 0,12 0,2 0,28 0,36 0,44 0,52 0,6
Distance [Inches]
-0,24 -0,09 0,06
30
0,21
0,36
0,51
0,66
0,81
24
1,4
0,76
0,38
0
1,05
0,7
16
8
20
10
T
T
0,35
0
0
0
S
S
-0,35
-0,7
-1,05
-1,4
-10
-20
-30
-8
-0,38
-0,76
-16
-24
-6 -4 -2
0
2
4
6
8
10 12 14 16 18 20 22
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16
Distance [mm]
Distance [mm]
Fig. 5 M30 Flush
Fig. 6 M30 Non-flush
Sensors with IO-Link communication
Programmable via IO-Link: 33%, 50%, 75% or 100% of the maximum Sn
Factory setting: 100% of the maximum Sn
Programmable via IO-Link: standard or increased
Factory setting: standard
Rated operating distance Sn
Hysteresis (H)
Correction factors
The specific operating distance Sn refers to defined measuring conditions. The following data have to be
considered as general guidelines.
Fe360 : Steel
CrNi : Chrome-nickel
CuZn : Brass
Al : Aluminium
Cu : Copper
Sr : Effective operating distance
Fig. 7 The rated operating distance is reduced by
the use of metals and alloys other than Fe360. The
most important reduction factors for inductive prox-
imity sensors are shown in the figure.
Accuracy
Repeat accuracy (R)
≤ 5%
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
7
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
Features
Power Supply
Rated operational voltage (Ub)
Ripple (Urpp
10 to 36 VDC (ripple included)
≤ 10%
)
No load supply current (Io)
Power ON delay (tv)
≤ 20 mA
≤ 50 ms
Outputs
Configurable via IO-Link: PNP, NPN or push-pull
Factory setting: PNP
Output functions
Configurable via IO-Link: N.O. or N.C.
Factory setting: N.O.
Output configuration
Output current (Ie)
≤ 200 mA
OFF-state current (Ir)
(only for PNP or NPN output)
≤ 100 μA
Voltage drop (Ud)
Protection
Voltage transient
Max. 2.5 VDC @ 200 mA
Short-circuit, reverse polarity and transients
1 kV/0.5 J
Response times
≤ 2 kHz
≤ 1.5 kHz
≤ 1 kHz
ICB12
ICB18
ICB30
Operating frequency (f)
Indication
Standard IO mode:
Yellow LED
Output
Description
N.O. output, target not present
N.C. output, target present
OFF
OFF
N.O. output, target present
N.C. output, target not present
ON
ON
f: 2Hz
f: 1Hz
Short-circuit or overload
Temperature alarm (if enabled)
Blinking
Green LED
OFF
ON
Output
Description
Sensor is not operational
Sensor is operational
-
-
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
8
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
IO-Link mode:
Yellow LED
OFF / ON
Output
SIO
f: 2 Hz
f: 1 Hz
-
Description
Shows SIO status if no short circuit or temperature errors.
Short-circuit or overload
Temperature alarm (if enabled)
Blinking
Disabled
Possibility to disable the LED
Green LED:
• LED is ON for 0.75 s and OFF for 0.075 s
• Possibility to disable the LED
Environmental
Operating: -25° to +70°C (-13° to +158°F)
Storage: -30° to +80°C (-22° to +176°F)
Operating: -40° to +70°C (-40° to +158°F)
Storage: -40° to +80°C (-40° to +176°F)
Operating: 35% to 95%
Storage: 35% to 95%
10 to 55 Hz, amplitude 1.0 mm; sweep cycle 5
min; in X, Y and Z direction
Ambient temperature for cable ver-
sions
Ambient temperature for plug ver-
sions
Ambient humidity
Vibration
IEC 60068-2-6
Shock
Rough handling shocks
Degree of protection
30 G /11 ms. 10 shocks in X, Y and Z direction
2 times from 1m, 100 times from 0.5m
IP67
IEC 60068-2-27
IEC 60068-2-31
IEC 60529; EN 60947-1
Compatibility and conformity
8 kV air discharge
4 kV contact discharge
IEC 61000-4-2 Electrostatic discharge
IEC 61000-4-3 Radiated radiofre-
quency
IEC 61000-4-4 Burst immunity
IEC 61000-4-6 Conducted radio fre-
quency
3 V/m (ICB30: 12 V/m)
2 kV (ICB30: 4 kV)
3 V (ICB30: 10 V)
EMC protection
IEC 61000-4-8 Power frequency mag-
netic fields
30 A/m
ICB12: 3963 years @50°C (122°F)
ICB18: 3945,2 years @50°C (122°F)
ICB30: 3479,3 years @50°C (122°F)
MTTFd
®
Approvals
CCC is not required for products rated ≤ 36 V
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
9
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
Mechanical data
Cable version: short, flush: 76.2g; short, non-flush: 76.8g; long, flush:
82.2g; long, non-flush: 82.8g;
Plug version: short, flush: 29.5g; short, non-flush: 30.1g; long, flush:
35.2g; long, non-flush: 35.8g.
Cable version: short, flush: 100.3g; short, non-flush: 102.8g; long, flush:
112.6g; long, non-flush: 115.1g;
Plug version: short, flush: 57.4g; short, non-flush: 59.9g; long, flush:
69.8g; long, non-flush: 72.3g.
Cable version: short, flush: 191.1g; short, non-flush: 197.6g; long, flush:
219.4g; long, non-flush: 226g;
Plug version: short, flush: 127g; short, non-flush: 133.5g; long, flush:
159.6g; long, non-flush: 166.1g.
M12
M18
M30
Weight (including 2 nuts and the
packaging) max.
Mounting
Material
Flush mountable or non-flush mountable
Housing: Nickel-plated brass
Front cap: Grey thermoplastic polyester
ICB12: 10 Nm
ICB18: 25 Nm
ICB30: 30 Nm
Max tightening torque
Electrical connection
ICB12 and ICB18: 2m, 3 x 0.25 mm2, Ø4.1 mm, PVC, grey, oil proof
ICB30: 2m, 3 x 0.34 mm2, Ø5.2 mm, PVC, grey, oil proof
M12 x 1, 4 pin, male connector
Cable
Plug
Communication
Communication
Via IO-Link V1.1 or via standard I/O
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
10
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
Connection Diagrams
+
+
1 BN
1 BN
4 BK
4 BK
3 BU
Fig. 8 NPN - Normally open
1 BN
3 BU
-
-
Fig. 9 NPN - Normally closed
+
+
1 BN
4 BK
4 BK
3 BU
3 BU
-
-
Fig. 10 PNP - Normally open
Fig. 11 PNP - Normally closed
+
1 BN
4 BK
Out/IO-Link
3 BU
-
Fig. 12 IO-Link
Colour code
BN: brown
BK: black
BU: blue
Wire colors in accordance with EN 60947-5-2
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
11
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
Dimensions [mm]
ICB12 [mm]
4
4
SW17
7.5
SW17
LED
LED
7.5
2x lock washer
2x lock washer
30
32
4
30
36
Fig. 13 Short body, flush version, cable
Fig. 14 Short body, non-flush version, cable
4
1
3
2
4
1
3
2
33.2
33.2
Ø3 LEDx4
Ø3 LEDx4
4
SW17
4
SW17
8.2
8.2
7.5
7.5
11.1
11.1
2x lock washer
2x lock washer
30
4
30
50.2
54.2
Fig. 15 Short body, flush version, plug
Fig. 16 Short body, non-flush version, plug
4
SW17
4
SW17
LED
LED
7.5
7.5
2x lock washer
2x lock washer
50
52
4
50
56
Fig. 17 Long body, flush version, cable
Fig. 18 Long body, non-flush version, cable
4
1
3
2
4
1
3
2
53.2
SW17
53.2
SW17
Ø3 LEDx4
8.2
Ø3 LEDx4
8.2
4
4
7.5
7.5
11.1
11.1
2x lock washer
2x lock washer
4
50
50
74.2
70.2
Fig. 19 Long body, flush version, plug
Fig. 20 Long body, non-flush version, plug
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
12
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
ICB18 [mm]
4
SW24
4
SW24
LED
LED
7.5
7.5
2x lock washer
2x lock washer
30
32
10
30
42
Fig. 21 Short body, flush version, cable
Fig. 22 Short body, non-flush version, cable
4
1
3
2
4
1
3
2
36.5
36.5
4
SW24
4
SW24
Ø3 LEDx4
8
Ø3 LEDx4
8
7.5
54
11
7.5
64
11
2x lock washer
2x lock washer
30
10
30
Fig. 23 Short body, flush version, plug
Fig. 24 Short body, non-flush version, plug
4
SW24
4
SW24
LED
LED
7.5
7.5
2x lock washer
2x lock washer
50
10
50
52
62
Fig. 25 Long body, flush version, cable
Fig. 26 Long body, non-flush version, cable
4
1
3
2
4
1
3
2
56.5
SW24
56.5
SW24
4
4
Ø3 LEDx4
8
Ø3 LEDx4
8
7.5
11
7.5
11
2x lock washer
2x lock washer
10
50
50
84
74
Fig. 27 Long body, flush version, plug
Fig. 28 Long body, non-flush version, plug
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
13
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
ICB30 [mm]
5
5
SW36
SW36
LED
LED
2x lock washer
2x lock washer
12
30
30
32
44
Fig. 29 Short body, flush version, cable
Fig. 30 Short body, non-flush version, cable
4
1
3
2
4
1
3
2
37.5
37.5
5
5
SW36
SW36
Ø3 LEDx4
8
Ø3 LEDx4
8
9
9
2x lock washer
2x lock washer
12
30
30
67
55
Fig. 31 Short body, flush version, plug
Fig. 32 Short body, non-flush version, plug
5
SW36
5
SW36
LED
LED
2x lock washer
2x lock washer
50
12
50
52
64
Fig. 33 Long body, flush version, cable
Fig. 34 Long body, non-flush version, cable
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
14
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
4
1
3
2
4
1
3
2
57.5
SW36
57.5
SW36
5
5
Ø3 LEDx4
8
Ø3 LEDx4
8
9
9
2x lock washer
2x lock washer
50
87
12
50
75
Fig. 35 Long body, flush version, plug
Fig. 36 Long body, non-flush version, plug
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
15
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
Installation
M12, M18 and M30 flush
d
d
d
**
≥ 3 x Sn
d
Fig. 37 Flush sensor, when installed in damping
Fig. 38 Flush sensors, when installed together in
material
damping material
M12 and M18 non-flush
d
d
2 x d
d
d
≥ 3 x d
d
≥ 3 x Sn
**
Fig. 39 Non-flush sensor, when installed in damping Fig. 40 Non-flush sensors, when installed together in
material
damping material
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
16
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
M30 non-flush
d
d
4 x d
d
d
≥ 4 x d
d
≥ 3 x Sn
**
Fig. 41 Non-flush sensor, when installed in damping
Fig. 42 Non-flush sensor, when installed together in
material
damping material
Sensors installed opposite each other
≥ 6 x Sn
Fig. 43 For sensors installed opposite each other, a minimum space of 6 x Sn (the nominal sensing dis-
tance) must be observed
** Free zone or non-damping material
Sn: nominal sensing distance
d : sensor diameter (12 mm for ICB12, 18 mm for ICB18, 30 mm for ICB30)
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
17
ICB12, ICB18 & ICB30 IO-Link 3-wire DC
Delivery contents and compatible components
Delivery contents
• Inductive proximity switch
• 2 fixing nuts
• 2 lock washers
• Packaging: plastic bag
CARLO GAVAZZI compatible components
• Mounting bracket AMB8... to be purchased separately
• Connector type: CONB1... series to be purchased separately
Further reading
Information
Where to find it
QR
IO-Link manual
Mounting brackets
Connectors
http://www.productselection.net/MANUALS/UK/IOL_IM.pdf
http://www.productselection.net/Pdf/UK/AMB8_30.pdf
http://www.productselection.net/Pdf/UK/CONB14NF.pdf
COPYRIGHT ©2018
Content subject to change. Download the PDF: www.productselection.net
21/05/2018 ICB12, ICB18 & ICB30 IO-Link 3-wire DC DS EN
Carlo Gavazzi Automation S.p.A.
18
相关型号:
ICB12S30F04NCM1
Proximity Inductive Sensors Extended Range, Nickel-Plated Brass Housing
CARLOGAVAZZI
ICB12S30F04NOM1
Proximity Inductive Sensors Extended Range, Nickel-Plated Brass Housing
CARLOGAVAZZI
ICB12S30F04PCM1
Proximity Inductive Sensors Extended Range, Nickel-Plated Brass Housing
CARLOGAVAZZI
ICB12S30F04POM1
Proximity Inductive Sensors Extended Range, Nickel-Plated Brass Housing
CARLOGAVAZZI
©2020 ICPDF网 联系我们和版权申明